Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutSR Swanson River Storage - Hilcorp Alaska LLCState of Alaska AOGCC Gas Disposition Files Year: 2015 Facility: SR Swanson River Storage Operator: Hilcorp Alaska LLC     STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION Revised FAr it ITV REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. Month/Year of Disposition I January 2015 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 81139 Pool Name Pool Code Percent 7. Reinjected` Includes Transferred Gas. See Remarks 89,842 B. Flared or vented 1 hour or less 11 9. Flared or vented more than 1 hour (See inslr.) 36 SWANSON RIVER, GAS STORAGE 772803 1.03% SWANSON RIVER, GAS STORAGE 772805 98.97% 10. Pilot and Purge 108 11. Assist Gas 0 12. Fuel gas used in lease operations 5,886 13. Other (see instructions) 0 Official Use Only Authorization>l hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) • Includes Transferred 157,022 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field Other 15708 89,174 668 89,842 Injected into Storage 139,158 Transferred Gas used as Fuel: - Storage Inv. 3,136,054 1 hereby certify that the foregoing is true and correct to the best of my knowledge. 7� SignatureyNi�' Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 10/21/2015 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FEB 2 3 2015 A®GVQ 1 FACILITY REPORT 1. Facility Number 2. Facility Name 1330000081 Swanson River Stora a Disposition OF PRODUCED 3. Field Swanson Volume MCF GAS umruS' u�i. 5. Month/Year of Disposition 4. Operator River Unit HILCORP ALASKA LLC Janua 2015 20. For production from multiple pools, list contribution of each pool as a percent of Tota Volume. 6. Sold 61,139 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 89,842 8. Flared or vented 1 hour or less 11 SWANSON RIVER, GAS STORAGE 772803 1'03"/0 9. Flared or vented more than 1 hour (see instr.) 36 SWANSON RIVER, GAS STORAGE 772805 96.97% 10. Pilot and Purge 108 11. Assist Gas 0 12. Fuel gas used in lease operations 5,886 Official Use Only 13. Other (see instructions) 0 Authorization >t hr Safety MCF 14. TOTAL VOLUME (ITEMS 6.13)' Includes Transferred 157,022 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF s' 12 1 i 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks:139,158 Transferred From Swanson River Field 89,174 Injected into Storage Other 1570B 668 Transferred Gas used as Fuel: - 89,842 Storage Inv. 3,090,732 I hereby certify that the foregoing is true and correct to the best of my knowledge. (n6 7� Title Production Analyst v Note: All volumes must be comacted to pressure of 14.65 psia and to a temperature of 600 F. Authority 20 AAC25.235. Signature Printed Name Cortne Der Phone 713-289-2881 Date 2/18/2015 V -r I- 3119115 OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDater124250 Facil No Date Flared Start Time Endin Time End Date Planned MCF Description of FlaringEvent Volume Excess venting necessary until Excess venting due to shutdown of cooler could be repaired and 01/01/2015 1330000081 1/16/2015 10:00:00 PM 1:30:00 PM 1/17/2015 U 3.9 Compressor K-22 for unscheduled compressor brought back maintenance to fix a leaky gas cooler. online. Excess venting due to unscheduled Excess venting necessary until shutdown of Compressor K-22 oil and plugs could be changed 01/01/2015 1330000081 1/19/2015 10:00:00 AM 6:00:00 PM 1/19/2015 U 2.0 because of low compressor lube and compressor brought back pressure. online. Excess venting due to shutdown of Excess venting necessary until Compressor K-8 caused by maintenance could be 01/01/2015 124250 1330000081 1/20/2015 12:35:00 AM 8:55:00 PM 1/23/2015 U 23.1 unscheduled maintenance after losing completed and compressor a piston cylinder. brought back online. Excess flaring necessary until Excess flaring due to shutdown of the shuttle valve on the drip 01/01/2015 124250 1330000081 1/22/2015 10:30:00 AM 6:00:00 PM 1/22/2015 U 7.0 Compressor K-8 for unscheduled counter was replaced and maintenance caused by lube failure. compressor brought back online. STATE OF ALASKA Revised ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator HILCORP ALASKA LLC 5. Month/Year of Disposition February 2015 Disposition Volume MCF 20. For production from multiple pools, list contribution Volume. of each pool as a percent of Total 6. Sold 111,394 Pool Name Pool Code Percent 7. Reinjected* Includes Transferred Gas. See Remarks 35,098 8. Flared or vented 1 hour or less 13 9. Flared or vented more than 1 hour (see instr.) 2 SWANSON RIVER, GAS STORAGE 772803 27.39% SWANSON RIVER, GAS STORAGE 772805 72.61% 10. Pilot and Purge 32 11. Assist Gas 0 12. Fuel gas used in lease operations 2,780 13. Other (see instructions) 0 Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) * Includes Transferred 149,319 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field Other 15708 35,089 0 35,089 Injected into Storage 56,061 Transferred Gas used as Fuel: - Storage Inv. 3,056,922 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signaturey4/�2 l� 17 9 Printed Name Cortney Der Title Production Analyst Phone 713-289-2881 Date 10121120151 Note: All volumes must be corrected to pressure of 14.65 pale and to a temperature of 60o F. Authority 20 AAC25.235. STATE OF ALASKA Revised ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4, Operator HILCORP ALASKA LLC 5. Month/Year of Disposition March 2015 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 83,891 Pool Name Pool Code Percent 7. Reinjected* Includes Transferred Gas, See Remarks 41,993 8. Flared or vented 1 hour or less 4 9. Flared or vented more than 1 hour (See inetr.) 27 SWANSON RIVER, GAS STORAGE 772803 14.73% SWANSON RIVER, GAS STORAGE 772805 85.27% 10. Pilot and Purge 61 11. Assist Gas 0 12. Fuel gas used in lease operations 2,892 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) * Includes Transferred 128,808 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 41,991 Injected into Storage 62,058 Other 15708 2 Transferred Gas used as Fuel: - 41,993 Storage Inv. 3,012,039 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature 7� — Title Production Analyst Note: All volumes must corrected to pressure of 14.65 psisia and to a temperature o/ 60o F. Authority 20 of60o 35. Printed Name Cortney Dyer Phone 713-289-2881 Date 10/21/2015 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION RECEIVED APR 2 2 2015 A®GCC 1. Facility Number 1330000081 2. Facility Name I Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. Month/Year of Disposition March 2015 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 83,891 Pool Name Pool Code Percent 7. Reinjected" Includes Transferred Gas. See Remarks 41,993 8. Flared or vented 1 hour or less 4 9. Flared or vented more than 1 hour (see instr.) 27 ✓ SWANSON RIVER, GAS STORAGE 772803 14.73% SWANSON RIVER, GAS STORAGE 772805 85.27% 10. Pilot and Purge 61 11. Assist Gas 0 12. Fuel gas used in lease operations 2,892 13. Other (see instructions) 0 - A Official Use Only Authorization>1 hr Safety 2 MCF 14. TOTAL VOLUME (ITEMS 6.13)" Includes Transferred 128,868 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas- Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 `f'�`-� s —�2 -,/S- 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field Other 15706 41,991 2 41,993 Injected into Storage 139,158 Transferred Gas used as Fuel: - Storage Inv. 3,250,883 1 hereby certify that the foregoing is true and correct to the best of my knowledge. 7-� Signature DN�� Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 4120120151 vT� RECEIVED APR 2 2 2015 ALOY CC OR FLARING R tOate EVENTS O No GREATER THAN FacilityNo 1 HOUR Date Flared. Start Time EndingTime End Dale Planned MCF Description of Flaring Event coon Taken toMimmize--? Volume Excess venting necessary until Excess venting due to Compressor K- the cylinder liner could be 03/01/2015 124250 1330000081 3/13/2015 3:15:00 PM 4:30:00 PM 3/23/2015 U 271 22 losing a cyclinder. repaired, new piston machined and installed. 6 P, W, I �YA-Y'061 STATE OF ALASKA Revised ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Stora a 3. Field Swanson River Unit 4. Operator HILCORP ALASKA LLC 5. Month/Year of Disposition Aril 2015 Disipwition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 263,029 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 21,654 8. Flared or vented 1 hour or less 29 9. Flared or vented more than 1 hour (see instr.) 15 SWANSON RIVER, GAS STORAGE 772803 48.04% SWANSON RIVER, GAS STORAGE 772805 51.96% 10. Pilot and Purge 51 11. Assist Gas 0 12. Fuel gas used in lease operations 3,148 13. Other (see instructions) 0 Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6.13) . Includes Transferred 287,926 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field Other 15706 21,654 0 21,654 Injected into Storage 48,489 Transferred Gas used as Fuel: - Storage Inv. 2,767,422 � 1 hereby certify that the foregoing is true and correct to the best of my knowledge. ,w,-�� ,n, II.. Signature -��"�iyy — Title Production Analyst —Note:. -Aft volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortne Dyer Phone 713-289-2881 Date 10/21!2015 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION aAnll IN PPPOPT OF PPOni ICFO r:AS DISPOSITION RECEIVED MAY 2 l 2015 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. OperatornthNear HILCORP ALASKA LLC 5. Mo of Disposition Aril 2015 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pod as a percent of Total Volume. 6. Sold 263,029 Pool Name Pool Code Percent 7. Reinjected` Includes Transferred Gas. See Remarks 21,654 8. Flared or vented 1 hour or less 29 9. Flared or vented more than 1 hour (see instr.) 15 SWANSON RIVER, GAS STORAGE 772803 48.04% SWANSON RIVER, GAS STORAGE 772805 51.96% 10. Pilot and Purge 51 11. Assist Gas 0 12. Fuel gas used in lease operations 3,148 13. Other (see instructions) 0 Official Use Only Authorization > 1 hr. Safety / r d' MCF 14. TOTAL VOLUME (ITEMS 6.13). Includes Transferred 287,926 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner (j ' ZS —/,S- .i18. Date 18. Transferred to: 0 19, Remarks: Transferred From Swanson River Field Other 1570B 21,654 0 21,654 Injected into Storage 139,158 Transferred Gas used as Fuel: - Storage Inv. 3,495,501 1 hereby certify that the foregoing is true and correct to the best of my knowledge. 7-� Signature �� DNS- Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 pale and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 5/15/2015 OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize Rai 0 No I FacilNo Cate Rated Start Time Ending Time End Dale Planned MCF Description of Flaring Event Volume Excess venting necessary until maintenance could be Excess venting due to unscheduled completed and compressor 04/0112015 124250 1330000081 4/9/2015 8:45:00 AM 5:30:00 PM 4/11/2015 U 6.7 shutdown of Compressor K-22 brought back online. Cylinder because of lost cylinder al. head was made and compressor repaired. Excess venting necessary until maintenance could be Excess venting due to unscheduled completed and compressor 2:00:00 PM 4/13/2015 U 5.1 shutdown of Compressor K-22 brought back online. Cylinder 04/01/2015 124250 1330000081 4/11/2015 7:30:00 PM because of major cooling system p2 was inspected and field issues. found piston was damaged. Pairs were ordered. Excess flaring necessary until Excess venting due to shutdown of maintenance could be 04/01/2015 124250 1330000081 4/17/2015 9:30:00 AM 11:30:00 AM 4/17/2015 P 02 compressor K-22 for service to 20v-1. completed and compressor brought back online. Excess flaring necessary until 1.5 Excess Flaring due to K-12 scrubber valve could be located and 04107/2015 124250 1330000087 4/20/2015 1:00:00 AM 2:30:00 AM 4/20/2015 U dump valve stuck open. closed. Excess venting due to unscheduled Excess venting necessary until shutdown of Compressor K-22 for repairs could be com plate and 04/012015 124250 1330000081 4/25/2015 9:30:00 PM 10:00:00 AM 4/26/2015 U 1.5 repair of an impeller on circulation compressor brought back pump. online. STATE OF ALASKA Revised ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT 2. Facility Name 1. Facility Number y 1330000081 1 Swanson River Stora a Dis osition OF PRODUCED 3. Field Swanson Volume MCF 1 VMO DiSP 4. Operator 5. Month/Year of Disposition p River Unit I HILCORP ALASKA LLC I May 2015 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 58,690 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 93,576 8. Flared or vented 1 hour or less 29 SWANSON RIVER, GAS STORAGE 772803 26.37% 9. Flared or vented more than 1 hour (see inslr.) 44 SWANSON RIVER, GAS STORAGE 772805 73.63% 10. Pilot and Purge 116 11. Assist Gas 0 12. Fuel gas used in lease operations 5,093 Official Use Only 13. Other (see instructions) 0 Authorization >1 hr. Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 157,548 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field 92,244 Injected into Storage 122.248 Other 15706 1,332 Transferred Gas used as Fuel: - 93,576 Storage Inv. 2,797,025 I hereby certify that the foregoing is rue and correct to thee est of my knowledge. Dy - Title Production Analyst umes must be corrected to Not7press7ure of 14.65 pate and to aSignature te of 60o F. Authority 20 AAC25.235. Printed Name Cortne Dyer Phone 713-289-2881 Date 10/21/2015 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION ww...+.. rocen—mnuFACiLi Y REPORT yr r nw 1. Facility Number 2. Facility Name 1330000081 1 Swanson River Storage Disposition 3. Field Swanson Volume MCF 4. Operator 5. MonthfVear of Disposition River Unit I HILCORP ALASKA LLC I May 2015 20. For production from multiple pools, list conmDution of each pool as a percent of Total Volume. 6. Sold 58,690 Pool Name Pool Code Percent 7. Reinjected* Includes Transferred Gas. See Remarks 93,576 8. Flared or vented 1 hour or less 29 9. Flared or vented more than 1 hour (see instr.) 44 SWANSON RIVER, GAS STORAGE 772803 26.37% SWANSON RIVER, GAS STORAGE 772805 73.63% 10. Pilot and Purge 116 11. Assist Gas 0 12. Fuel gas used in lease operations 5,093 13. Other (see instructions) 0 Oficial use Authorization >1 hr Safety14. TOTAL VOLUME (ITEMS 6-13) • Includes Transferred 157,548 Lease Use15. !ET NGL Gas Equivalent 0 Conservation16. Purchased gas -Transferred from SRF 0Waste. 17. Transferred from: (Off -lease Gas) 0 lQ — / — l .S 18. Transferred to: 0 Co missioner Date 19. Remarks: Transferred From Swanson River Field 92,244 Injected into Storage 722,248 Other 1570B 1,332 Transferred Gas used as Fuel: - 93,576 Storage Inv. 3,429,761 I hereby certify that the foregoing is true and correct to the best of my knowledge. -�^7�r�'pnessure Signature�. 1 v yam' Title Production Analyst te: All volumes must be corrected to of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 6/18/2015 IITL Ikg/15- OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize FliptDate, O No Facili No. Date Flared Start Time Endin Finn End Date --.. Planned MOF Description of Flaring Event Volume Excess venting due to Compressor K- 22 repairstocylinderair Excessventingou necessary until 05/01/2015 124250 1330000081 5/2/2015 7:45:00 PM 1:00:00 PM 5/6/2015 U 19.9 Venting will be ongoing until repairs Venting ill repairs could be made. are made. Excess venting necessary until Excess venting due to scheduled maintenance could be 05/01/2015 124250 1330000081 5/8/2015 8:15:OOAM 12:45:00 PM 5/8/2015 P 1.0 maintenance on Compressor K-22 to completed and compressor install compressor thermowells. restarted. Excess flaring necessary until AM 5/11/2015 U 2.7 Excess flaring due to 1-27 tank setting the tank could be shut in and 05/01/2015 124250 1330000081 5/11/2015 6:00:00 AM 8:00:00 vessle gassing threw a dump valve. fixed. Excess venting due to a leaky valve on Excess venting necessary until 05/01/2015 124250 1330000081 5/22/2015 9:00:00 AM 12:00:00 PM 5/22/2015 U 15.4 the 1901 PSV. Repair parts were grease could be pumped into ordered. the valvle. Excess venting due to unscheduled Excess venting necessary until 05/01/2015 124250 1330000081 5/24/2015 9:00:00 AM 11:00:00 AM 5/24/2015 U 0.4 shutdown of Compressor K-22 because of high vapors from Tank 22 compressor could be loaded which overloaded the compressor. and restarted. Excess venting due to shutdown of Excess venting necessary until PM 5/30/2015 U 0.8 Compressor K-22 caused by high the compressor cooled and 05/01/2015 124250 1330000081 5/30/2015 3:00:00 PM 6:30:00 ambiant temperature causing Common temperature shut down. restarted. Excess venting necessary until Excess venting due toapower outage power could be restored and 05/01/2015 124250 1330000081 5/31/2015 7:15:00 AM 9:30:00 AM 5/31/2015 U 0.8 which caused the unavoidable Compressor could be brought shutdown of Compressor K-22. back online. Excess flaring necessary until Excess flaring due too power outage power could be restored and 05/01/2015 124250 1330000081 5/31/2015 7:15:OOAM 10:30:00 AM 5/31/2015 U 1.0 which caused the unavoidable Compressor could be brought shutdown of Compressor K-8. back online. Excess venting due to high Excess venting necessary until 05/01/2015 124250 1330000081 5/31/2015 7:15:OOAM 10:00:00 PM 5/31/2015 U 2.0 temperature shutdown of the compressor cooled and Compressor K-22. restarted. K OR FLARING EVENTS GREATER THAN i HOUR Action Taken to Minimize R tDale Deep Facmt No Date Flared Start Time EndingTime End Date Planned MCF Description of Flaring Event Volume Excess venting due to Compressor K- 22 down repairs cylinder until Excessventingould 05101/2015 124250 1330000081 5/2/2015 7:45:00 PM 100:00 PM 5/6/2015 U 19.9 n air Venting will be ongoing until repairs ill be repairs could be made. are made. Excess venting necessary until Excess venting due to scheduled maintenance could be 05/01/2015 124250 13300000B1 5/8/2015 8:15:00 AM 12:45:00 PM 5/8/2015 P 1.0 maintenance on Compressor K-22 to completed and compressor install compressor thermowells. restarted. Excess flaring necessary until 05/01/2015 124250 1330000081 5/11/2015 6:00:00 AM 8:00:00 AM 5/11/2015 U 2.7 Excess flaring due to 1-27 tank setting vessle gassing threw a dump valve. the tank mold shut in and d. fixed. Excess venting due to a leaky valve on Excess venting necessary until 05/01/2015 124250 1330000081 5/22/2015 9:00:00 AM 12:00:00 PM 5/22/2015 U 15.4 the 1901 PSV. Repair parts were grease could be pumped into ordered. the valvle. Excess venting due to unscheduled Excess venting necessary until 05101/2015 124250 1330000081 5/24/2015 9:00:OOAM 13:00:00 AM 5/24/2015 U 0.4 shutdown of Compressor Tank because of high vapors from Tank 22 compressor could be loaded and restarted. which overloaded the compressor. Excess venting due to shutdown of Excess venting necessary until 05101/2015 124250 1330000081 5/30/2015 3:00:00 PM 6:30:00 PM 5/30/2015 U 0.8 Compressormperaturec the compressor cooled and ambont cauby sing restarted. temperatureshut down. Common temperature shut down. Excess venting necessary until Excess venting due to a power outage power could be restored and 05/01/2015 124250 1330000081 5/31/2015 7:15:00 AM 9:30:00 AM 5/31/2015 U 0.8 which caused the unavoidable Compressor could be brought shutdown of Compressor K-22. back online. Excess flan ng necessary until Excess flaring due to a power outage red and could be powerssorcould 05101/2015 124250 1330000081 5/31/2015 7:15:00 AM 10:30:OOAM 5/31/2015 U 1.0 which caused the unavoidable be brought Compressor could be hrought shutdown of Compressor K-8. back online. Excess venting due to high Excess venting necessary until 05/01/2015 124250 1330000081 5/31/2015 7:15:00 AM 10:00:00 PM 5/31/2015 U 2.0 temperature shutdown of the compressor cooled and Compressor K-22. restarted. STATE OF ALASKA Revised ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS rIISPnSITlnN 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator HILCORP ALASKA LLC 5. Month/Year of Disposition June 2015 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 62,908 Pool Name Pool Code Percent 7. Reinjected` Includes Transferred Gas. See Remarks 45,818 B. Flared or vented 1 hour or less 3 9. Flared or Vented more than 1 hour (see instr.) 22 SWANSON RIVER, GAS STORAGE 772803 7.05% SWANSON RIVER, GAS STORAGE 772805 92.95% 10. Pilot and Purge 48 11. Assist Gas 0 12. Fuel gas used in lease operations 2.710 13. Othersee instructions ( ) 0 Official Use Only Authorization hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6.13) . Includes Transferred 111,509 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field 45,101 Injected into Storage 60,981 Other 15708 717 Transferred Gas used as Fuel: - 45,818 Storage Inv. 2,777,152 � I hereby certify that the foregoing is true and correct to the best of my knowledge. Ti Signature 1 v yam' Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 10/21/2015 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION EPORT OF PRODUCED GAS DISPOSITION FACILITY R 1. Facility Number 2. Facility Name 1330000081 Swanson River Storage Dis osition 3. Field Swanson Volume MCF 4. Operator 5. Month/Year of Disposition River Unit HILCORP ALASKA LLC June 2015 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 62.908 Pool Name Pool Code Percent 7. Reinjected` Inductee Transferred Gas. See Remarks 45,818 8. Flared or vented 1 hour or less 3 9. Flared or vented more than 1 hour (see instr.) 22 SWANSON RIVER, GAS STORAGE 772803 7.05% SWANSON RIVER, GAS STORAGE 772805 92.95% 10. Pilot and Purge 48 11. Assist Gas r; �,�-,;. .�: 12. Fuel gas used in lease operations 0 13. Other (sea instructions) 0 Official Use Onl Authorization >1 hr Safety MCF 14. TOTAL VOLUME (ITEMS 6.13)' Includes Transferred 111,509 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: IMCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 45,101 Injected into Storage 60,981 Other 15706 717 Transferred Gas used as Fuel: - 45,818 Storage Inv. 3,449,634 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Lam" `^-""^�y4i�' Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortne Der Phone 713-289-2881 Date 7/20/2015 VT1— OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R [Date O No I Faclli o Date Flared Stan Time Ending Time End Date Planned MCF Description of Fishing Event Volume Excess venting due to unscheduled Excess venting necessary until 06/01/2015 124250 1330000081 6/13/2015 4:00:00 PM 7:00:00 PM 6/13/2015 U 0.4 shutdown of Compressor K-22 compressor could be cooled caused by high temperature issues. andrestarced. Excess venting due to unscheduled Excess venting necessary until 06/01/2015 124250 1330000081 6/14/2015 1:30:00 PM 8:30:00 PM 6/14/2015 U 0.9 shutdown of Compressor K-22 caused the compressor could be by overheating. cooled and restarted. Excess venting due to high Excess venting necessary until 06/01/2015 124250 1330000081 6/15/2015 31:30:00 AM 5:00:00 PM 6/15/2015 U 0.7 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess flaring due to multiple high Excess flaring necessary until 06/01/2015 124250 1330000081 6/15/2015 5:45:00 PM 10:45:00 PM 6/15/2015 U 2.0 temperature shutdowns of the compressor could cool Compressor K-8. down and restarted. Excess venting due to high Excess venting necessary until 06101/2015 124250 1330000081 6/15/2015 6:00:00 PM 11:00:00 PM 6/15/2015 U 0.6 temperature shutdown of the Compressor cooled and Compressor K-22. restarted. Excess venting due to high Excess necessary until 6/16/2015 U 1.4 compressor cylinder temperatures comprventing ooled the compressor cooled and 06101/2015 124250 1330000081 6/16/2015 9:00:00 AM 8:00:00 PM caused by high ambient temperature and Compressor K-22 shutdown. restarted. Excess flaring due to high jacket Excess flaring necessary until 8:00.00 PM 6/16/2015 U 3.6 water low oi mperatures eCaused the compressor cooled and 06/012015 124250 1330000081 EPM ambient pressure caused by high ambient pressureby restarted. temperature. Excess venting due to unscheduled Excess venting necessary until 06/01/2015 124250 1330000081 6/17/2015 8:00:00 PM 6/19/2015 U 7.9 shutdown of Compressor K-22 caused the mechanics Can replace the by Comp cyli rider #1 going out. cylinder and complete repairs. Excess flaring due to high jacket Excess flaring necessary until 06/01/2015 124250 1330000081 6/17/2015 11:15:OOAM 11:15:00 PM 6/17/2015 U 4.2 water and compressor temperature Caused from high ambient compressor Could be cooled and restarted. temperatures. Excess venting due to blow down of Excess venting necessary unit 06/01/2015 124250 1330000081 6/27/2015 3:05:00 AM 4:35:00 AM 6/27/2015 P 0.1 production casing from 95psi to blow down could be 45psi. completed. Excess venting due to unscheduled Excess venting necessary until 06/01/2015 124250 1330000081 6/28/2015 11:45:00 AM 2:00:00 PM 6/28/2015 U 0.3 shutdown of Compressor K-22 caused the compressor could be by high temperatures. loaded and restarted. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION Revised veru ITE REPORT OF PRODUCED r_es D1gPnSITrnM 1. Facility Number 2. Facility Name 1330000081 Swanson River Storage Disposition 3. Field Swanson Volume MCF 4. Operator 5. Month/Year of Disposition River Unit HILCORP ALASKA LLC Jul 2075 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 154,100 Pool Name Pool Code Percent 7. Reinjected` Includes Transferred Gas, See Remarks 27,765 8. Flared or vented 1 hour or less 1 9. Flared Or Vented more than 1 hour (See inslr.) y SWANSON RIVER, GAS STORAGE 772803 35.38% SWANSON RIVER, GAS STORAGE 772805 64.62% 10. Pilot and Purge 40 11. Assist Gas 0 12. Fuel gas used in lease operations 2,673 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6.13)' Includes Transferred 184,588 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field 27,765 Injected into Storage 49,313 Other 15708 0 Transferred Gas used as Fuel: - 27,765 Storage Inv. 2,648,095 I hereby certify that the foregoing is true and correct to the best of my knowledge. /) "r' �y�' Signature l/�''6 Title Production Analyst Note: All volumes must is corrected to pressure off 60o psis and it a temperature o/ 60o F. Authority 20 AACP5.235. Printed Name Cortne Der Phone 713-289-2881 Date 10/21/2015 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1, Facility Number 2. Facility Name 1330000081 Swanson River Storage Disposition 3. Field Swanson Volume MCF 4. Operator onthlYear of Disposition River Unit HILCORP ALASKA LLC 5. MJul 2015 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 154,100 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 27,765 8. Flared or vented 1 hour or less 1 9. Flared or vented more than 1 hour (see insfr.) 9 SWANSON RIVER, GAS STORAGE 772803 35.38% SWANSON RIVER, GAS STORAGE 772805 64.62% 10. Pilot and Purge 40 11. Assist Gas 0 12. Fuel gas used in lease operations 2,673 13. Other (see instructions) 0 Official Use Only Authorization >t hr: Safety G' I MCF 14. TOTAL VOLUME (ITEMS 6-13). Includes Transferred 184,568 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 ®� —Z Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field 27,765 Injected into Storage 49,313 Other 15708 0 Transferred Gas used as Fuel: - 27,765 Storage Inv. 3,578,691 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Title Production Analyst Note: All volumes must be comacted to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Dyer Phone 713-289-2881 Date 8/12/2015 V T` R�ZlIS OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDate O No Facillt No Date Flared Start Time Ending Time End Date Planned MCF Desorption of Flaring Event Volume Excess venting due to unscheduled Excess venting necessary until shutdown of Compressor K-22 maintenance could be 07/01/2015 124250 1330000081 7/1/2015 7:30:00 PM 10:00:00 AM 7/2/2015 U 1.6 caused by high temperature and completed. high vibration. Excess venting due to unknown Excess venting necessary until 7/3/2015 11:00:00 AM 2:00:00 PM 7/3/2015 U 0.3 reasons, mechanic was contacted compressor could be 07/01/2015 124250 1330000081 and compressor restarted. restarted. Excess flaring necessary until Excess flaring due to high temperatures could be 07/01/2015 124250 1330000081 7/3/2015 5:30:00 PM 7:45:00 PM 7/3/2015 U 0.6 temperature shutdown of lowered and compressor Compressor K-8. brought back online. Excess venting due to 2-15 and 1-27 Excess venting necessary until 07/01/2015 124250 1330000081 7/7/2015 12:00:00 PM 2:00:00 PM 7/7/2015 P 0.0 tank settings lined to gauge tanks to tank gauging complete. flush north oil line. Excess venting due to scheduled Excess venting necessary until maintenance to flush lined fluid out lined fluids could be brou ht g 07/01/2015 124250 1330000081 7/10/2015 10:00:00 AM 1:00:00 PM 7/10/2015 P 0.1 of 1-27 TS and 2-15 TS between 1-27 back to ail line after Flush job. TS antl 1-33 TS. Excess flaring due to shutdown of Excess Flaring necessary until Compressor K-8 for scheduled maintenance could be 07/01/2015 124250 1330000081 7/12/2015 1:00:00 PM 4:30:00 PM 7/12/2015 P 1.8 maintenance to figure out low oil completed and compressor pressure problem. brought back online. Excess venting necessary until Excess venting due to bleed down the bleeding could be 07/01/2015 124250 1330000081 7/12/2015 1:30:00 PM 3:30:00 PM 7/12/2015 P 0.3 Wells 31-8 and 32-8 production complete and bleed valves casings. shut. Excess venting necessary until Excess venting due to bleed down the bleeding could be 07/01/2015 124250 1330000081 7/13/2015 1:15:00 PM 2:30:00 PM 7/13/2015 P 0.3 Wells 31-8 and 32-8 production complete and bleed valves casings. shut. Excess venting due to unscheduled Excess venting necessary until shutdown of Compressor K-22 on the governor could be 07/01/2015 124250 1330000061 7/16/2015 3:00:00 AM 7:00:00 AM 7/16/2015 U 0.4 overspeeding caused by a bad replaced and compressor governor. restarted. Excess venting necessary until Excess venting due to scheduled maintenance was completed 07/01/2015 124250 1330000081 7/23/2015 8:00:00 AM 3:45:00 PM 7/23/2015 P 0.4 shutdown of the K-22 Compressor and compressor loaded and for repair and maintenance. restarted. Excess flaring due to shutdown of K- Excess flaring necessary until 8 Compressor caused by shutdown repairs to K-22 Compressor 07/01/2015 724250 1330000081 7/23/2015 9:00:00 AM 3:00:00 PM 7/23/2015 P 1.6 of K-22 Compressorfor were complete and both units maintenance. loaded and restarted. 07/01/2015 1 124250 07/01/2015 1 124250 07/01/2015 1 124250 07/01/2015 1 124250 GREATER THAN 1 HOUR Action aken to Minimize Start Time Endin Time End Data Planned MCF Desai lion of Fladn Event Volume Facilit o Date Flared Excess venting due to unscheduled Excess venting necessary until shutdown of Compressor K-22 for repair were complete and 10:30:00 AM 7/24/2015 U 0.4 repairs made to starting panel and compressor brought back 1330000081 7/24/2015 7:30:00 AM k2 compressor cylinder head online. temperature probe. Excess venting necessary until Excess venting due to shutdown of the compressor could be 7/25/2015 3:30:00 AM 7:30:00 AM 7/25/2015 U 0.6 Compressor K-22 caused by low trouble shot and compressor 1330000081 engine oil pressure. loading and restarted. Excess flaring due to unscheduled Exess flaring necessary until shutdown of Compressor K-8 caused compressor could be loaded 1330000081 7/29/2015 1:15:00 PM 2:45:00 PM 7/29/2015 U 0.4 by high discharge pressure from and restarted. Field 150. Excess venting dueto unscheduled Excess venting necessary until shutdown of Compressor K-22 the compressor could be 1330000081 7/31/2015 7:00:00 PM 9:00:00 PM 7/31/2015 U 0.2 caused by high temperature and loaded and restarted. high discharge pressure. STATE OF ALASKA Revised ALASKA OIL AND GAS CONSERVATION COMMISSION nTeomm�nu FACILITY REPORT 1. Facility Number 2. Facility Name 1330000081 Swanson River Storo a Disposition OF PROD 3. Field Swanson volume MCF 4. Operator 5. Month/Year of Disposition River Unit HILCORP ALASKA LLC August 2015 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 148.837 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 18,714 8. Flared or vented 1 hour or less 0 SWANSON RIVER, GAS STORAGE 772803 69.56% 9. Flared or vented more than 1 hour (see instr.) 8 SWANSON RIVER, GAS STORAGE 772805 30.44% 10. Pilot and Purge 31 11. Assist Gas 0 12. Fuel gas used in lease operations 1.971 Official Use Onl 13. Other (see instructions) 0 Authorization Safety Q Cl MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 169,561 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF .3 — 9'/ 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field 18,017 Injected into Storage 32,827 Other 15706 697 Transferred Gas used as Fuel: - 18,714 Storage Inv. 2,515,963 hereby certify that the foregoing is true and correct to the best of my knowledge. y17� — Title Production Analyst _sure 7No1*,,:,PA1.-1m1UMes must be corrected to of 14.65 psia and to a9 ture of 60o F. Authority 20PrintedPhone Si nature 713-289-2881 Date 1021/2015AAC25.235. Y71— VZ-,? J / (- OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R IDaler124250 Facili No Date Flared Slart Time EndingTime End Date Planned MCF Doscri tion of FlaringEvent Volume Excess flaring due to unscheduled Excess flaring necessary until shuttlown of Compressor K-22 caused 08/01/2015 1330000081 8/3/2015 10:30:00 PM 11:59:00 PM 8/3/2015 U 0.3 by timer issues which led to compressor K-22 timer issues Compressor K-8 shutdown. fixed. Excess venting due to high Excess venting necessary until 08/01/2015 1330000081 8/4/2015 1:00:00 AM 5:45:00 AM 8/4/2015 U 0.4 temperature shutdown of the compressor could be Compressor K-22. cooled, loaded, and restarted. Excess flaring due to high Excess flaring necessary until 08/01/2015 124250 1330000081 8/4/2015 2:30:00 AM 6:00:00 AM 8/4/2015 U OA temperature shutdown of the compressor could be Compressor K-8. cooled, loaded, and restarted. Excess venting due to unscheduled Excess venting necessary until 08/01/2015 124250 1330000081 8/7/2015 4:30:00 PM 7:00:00 PM 8/7/2015 U 0.2 shutdown of Compressor K-8 which compressors could be caused Compressor K-22 to go down. restarted. Excess flaring due to unscheduled Excess flaring necessary until 08/01/2015 124250 1330000081 8/7/2015 4:30:00 PM 7:00:00 PM 8/7/2015 U 0.6 shutdown of Compressor K-8 caused compressor could be cooled by over heating. and restarted. Excess flaring necessary until Excess flaring due to shutdown of maintenance could be 08/01/2015 124250 1330000081 8/9/2015 7:00:OOAM 9:15:00 AM 8/9/2015 P 0.3 Compressor K-8 to replace a bad completed and compressor valve. brought back online. Excess venting necessary until Excess venting due to shutdown of maintenance on Compressor K- OBM1/2015 124250 1330000081 8/9/2015 7:45:00 AM 9:30:00 AM 8/9/2015 p 0.2 Compressor K-22 roused by 8 could be completed and both Compressor K-8being down for compressor brought back maintenance. online. Excess venting due to unscheduled Excess venting necessary until 08/01/2015 124250 1330000081 8/11/2015 4:30:00 PM 7:30:00 PM 8/11/2015 U 0.3 shutdown of Compressor K-22 caused temperature could he lowered by high common temperature. and compressor restarted. Excess venting due to scheduled Excess venting necessary until shutdown of Compressor K-22 for maintenance could be 08/01/2015 124250 1330000081 8/13/2015 31:30:00 AM 1:30:00 PM 8/13/2015 P 0.2 preventative maintenance to change completed and compressor the oil and spark plugs. brought back online. Excess flaring due to high compressor Excess flaring necessary until 08/01/2015 124250 1330000081 8/25/2015 9:00:OOAM 1:30:00 PM 8/25/2015 U 1.0 temperature shutdown of the compressor could be Compressor K-8. cooled, loaded, and restarted. Excess venting due to high common Excess venting necessary until 08/01/2015 124250 1330000081 8/25/2015 5:15:00 PM 11:59:00 PM8/25/2015 U 0.6 temperature shutdown of the compressor could be Compressor K-22. cooled, loaded, and restarted. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. Montt /Year of Disposition I Au ust 2015 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 148,837 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 18,714 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 8 SWANSON RIVER, GAS STORAGE 772803 69.56% SWANSON RIVER, GAS STORAGE 772805 30.44% 10. Pilot and Purge 31 11. Assist Gas 0 12. Fuel gas used in lease operations 1,871 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety p �J MCF 14. TOTAL VOLUME (ITEMS 6.13)' Includes Transferred 169,561 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste JMCF 17. Transferred from: (Off -lease Gas) 0 / j 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 18,017 Injected into Storage 32,827 Other 15708 697 Transferred Gas used as Fuel: - 18,714 Storage Inv. 3,710,823 1 hereby certify that the foregoing is true and correct to the best of my knowledge. /n.6 Signature C �yq Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortncy Der Phone 713-289-2881 Date 9/17/2015 OR FLARING EVENTS GREATER THAN 7 HOUR Action Taken to Minimize Voluble R tDate O No Facili o Date Flared Stan Time Ending Time End Date Planned MCF ExcDessoflanong dfue�o scheduled Excess flaring necessary until shutdown of Compressor K-8 for maintenance could be 08101/2015 124250 1330000081 8/26/2015 7:00:00 AM 9:30:00 AM 8/26/2015 P 0.5 Maintenanceta install newvalves and completed and compressor new AMOT. restarted. 08/0112015 124250 1330000081 6/26/2015 10:00:00 AM 10:00:00 PM 8/26/2015 U 1.0 Excess venting due to unscheduled shutdowns of Compressor K-22 caused by overheating issues. Excess venting necessary until compressor could he re startad. Excess Flaring due to shutdown of Excess Flaring necessary until maintenance could be 0810112015 124250 1330000081 8/27/2015 7:00:00 AM 11:30:07 AM 8/27/2015 P 1.0 Compressor K-8 to change compressor rings. completed and compressor brought back online. Excess venting due to unscheduled Excess venting necessary until 08101/2015 124250 1330000081 8/27/2015 7:30:00 AM 1:30:00 PM 8/27/2015 U 0.5 shhghcomfmon temCompressor K-22 for comturoadeor coinednd be soled, Excess venting due to unscheduled Excess venting necessary until 08/07/2015 124250 1330000081 8/28/2015 6:30:00 AM 8:00:00 AM 8/28/2015 U 0.1 shutdownbyhigh common temperature. sed d be rted led, compressorloaded and restarted. ss venting due to unscheduled Excess venting necessary until 081012015 724250 1330000081 8/30/2015 11:45:00 AM 4:45:00 PM 8/30/2015 UFOA Camp Thutdown highcommonetempe ature.zed caohed, loaded aond restarted. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION enercrnu 1. Facility Number 2. Facility Name r„y cr 1330000081 Swanson River Stora a Disposition I. Field vVVV�V Swanson Volume MCF V^ 4.Operator S. Month/Vear of Disposition River Unit HILCORP ALASKA LLC September 2015 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 93,046 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 44,440 8. Flared or vented l hour or less 0 9. Flared Or Vented more than 1 hour (See inalf.) 51 SWANSON RIVER, GAS STORAGE 772803 41. SWANSON RIVER, GAS STORAGE 772805 56.6363% 10. Pilot and Purge 90 11. Assist Gas 0 12. Fuel gas used in lease operations 3,130 13. Other (see instructions) 0 Official Use Only Authorization 11 hr Safety !j / MCF 14. TOTAL VOLUME (ITEMS 6.13) . Includes Transferred 140,757 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 �( V ' — 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 41,071 Injected into Storage 69,036 Other 15708 3,369 Transferred Gas used as Fuel: - 44,440 Storage Inv. 2,464,084 I hereby certify that the foregoing is true and correct to the best of my knowledge. ,1 7� Signature 1/. '�•, v Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 Aof 60o Printed Name Cortney Dyer Phone 713-289-2881 Date 10/20/2015 vT� /0/24//5 Swanson River Storage Action Taken to Minimize Cleric, Facllit No Date Flared StartTime Endin Time End Dale Planned MCF Description ofFlaring Event Volume R tDale Excess venting due to unscheduled Excess venting necessary until PM 9/4/2015 U 0.4 shutdown of Compressor K-22 caused temperature could be lowered 09101/2015 124250 1330000081 9/4/2015 9:30:00 PM 11:59:00 byhigh common temperature. and compressor restarted. Excess venting due to unscheduled Excess venting necessary until 4:30:00 AM 9/5/2015 U 0.4 shutdown of Compressor K-22 used temperature could be lowered 09/01/2015 124250 1330000081 9/5/2015 1:30:00 AM by high common temperature. and compressor restarted. Excess venting necessary until Excess venti ng due to unscheduled maintance on valve covers 7:30:00 AM 1:30:00 PM 9/5/2015 U 0.8 shutdown of Compressor K-22 for could be completed and 09/01/2015 124250 1330000081 9/5/2015 repairs. compressor brought back online. Excess venting necessary until Excess venting due to unscheduled maintance on valve covers 7:00:00 PM 9/5/2015 U 0.6 shutdown of Compressor K-22 for could be completed and 09/0112015 124250 1330000081 9/5/2015 3:00:00 PM repairs. compressor brought back online. Excess venting necessary until Excess venting due to shutdown of new VRU installation project 11:59:00 PM 9/30/2015 P 48.7 Compressor K-22 for installation of a can be completed and 09/01/2015 124250 1330000081 9/14/2015 8:00:00 AM replacement VRU. compressor brought back online. 51.0 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name 1 Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. MonthlYear of Disposition I October 2015 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume, 6. Sold 215,419 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 36,621 8. Flared or vented 1 hour or less 2 9. Flared or vented more than 1 hour (see instr.) 87 SWANSON RIVER, GAS STORAGE 772803 16.56% SWANSON RIVER, GAS STORAGE 772805 83.44% 10. Pilot and Purge 129 11. Assist Gas 0 12. Fuel gas used in lease operations 3,530 13. Other (see instructions) 0 Official Use Only Authorization >1 hr Safety $ MCF 14. TOTAL VOLUME (ITEMS 6.13) -Includes Transferred 255,788 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas- Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) o — /2 -/& -- 1.5 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field Other 15708 33,288 3,333 36,621 Injected into Storage 67,186 Transferred Gas used as Fuel: - Storage Inv. 2,281,539 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 11/16/2015 V%(-- lz JJ5/ 15 Swanson River Storage Excess venting due to unscheduled Excess venting necessary until 10/012015 124250 1330000081 10/1/2015 12:00:00 AM 3:30:00 PM 10/25/2015 P 85.1 shutdown of Compressor K-22 caused temperature could be lowered by high common temperature. and compressor restarted. Excess venting due to unscheduled Excess venting necessary until 10)012015 124250 1330000081 10/26/2015 12:00:00 PM 3:00:00 PM 10/26/2015 U 1.1 shutdown of Compressor K-22 caused temperature could be lowered by high common temperature. and compressor restarted. Excess venting necessary until Excess venting due to unscheduled maintance on valve covers 10/012015 124250 1330000081 10/26/2015 2:00:00 PM 4:45:00 PM 10/26/2015 U 0.4 shutdown of Compressor K-22 for could be completed and repairs. compressor brought back online. Excess venting necessary until Excess venting due to unscheduled maintance on valve covers 10M2015 124250 1330000081 10/30/2015 2:15:00 AM 3:30:OOAM 10/30/2015 U 0.4 shutdown of Compressor K-22 for could be completed and repairs. compressor brought back online. m.0 Swanson River Storage November -15 Excess venting necessary until 11/01/2015 124250 1330000081 11/3/2015 9:00:00 23:59:00 11/3/2015 U 21.0_ Excess venting due to a power the power could be restored outage and venting off of TR -22. and equipment brought back online. Excess flaring due to bringing up Excess flaring necessary until 11/01/2015 124250 1330000081 11/3/2015 9:00:00 23:59:00 11/3/2015 U 121.9 Plant and Field follawing power the power could be restored and equipment brought back outage. online. Excess venting due to unscheduled Excess venting necessary until 11/01/2015 124250 1330000081 11/16/2015 14:00:00 16:30:00 11/16/2015 U 3.5 shutdown of the VRU caused by a the cooler could be thawed out frozen cooler. with indirect heater. Excess flaring necessary until 11/01/2015 124250 1330000081 11/17/2015 13:00:0 17:00:00 11/17/2015 U 21.1• Excess flaring due to 20v-1 to VRU the the ice plug in the VRU compressor froze off. suction line could be thawed out. EthesVRUingdue an obstruction Excess flaring necessary until 11/0112015 124250 1330000087 11/19/2015 10:00:00 23:59:00 11/19/2015 U 11.9 freeo in the VRU liner and freezing issues in the obstruction could be cleared and ice from the lines the flare line. thawed. Excess venting due to an obstruction 11/01/2015 124250 1330000081 11/20/2015 0:00:00 12:00:0 11/20/2015 U 16.6 in the VRU pump screen which Excess venting necessary until xcescrentingen necessary essary until e cleaned caused 1st stage scrubber high leveling. and VRU restarted. Excess flaring due to fan motor 11101/2015 124250 1330000081 11/25/2015 0:30:00 5:00:0011/25/2015 U 9.1 - overload. Equipment was notable to Excess flaring necessary until be restarted immediately. the unit could be reset. Excess venting due to fan motor 11/01/2015 124250 1330000081 11/25/2015 0:30:00 5:00:00 11/25/2015 U 5.6 overload. Equipment was notable to n Excess venting necessary until serereset. be restarted immediately. the uniting be 11/01/2015 124250 1330000081 11/26/2015 14:45:00 17:0:00 11/26/2015 U 6.5 Bringing on wells after power outage; Excess flaring necessary until 45g Flare compressor could be restarted. 11/07/2015 724250 7330000061 11/26/2015 5:00:00 1100 11/26/2015 U 9.4' Excessing venting due to power Excess venting necessary until the the equipment could be outage. restarted. 11/01/2015 124250 1330000081 11/26/2015 5:00:0011:00:00 11/26/2015 U 34.7 Excessing flaring due to power Excess flaring necessary until - outage. the equipment could be restarted. River 11/0112015 124250 1330000081 11/26/2015 5:10:00 11:25:00 11/26/2015 U 195.1. Excessing flaring at main flare due to I Excess flaring necessary until poweroutage. the wells could be shut in. 11/01/2015 124250 1330000081 11/26/2015 14:45:00 16:15:00 11/26/2015 U 76.5" Excessing flaring due to bringing the Excess flaring necessary until wells on after power outage. compressor could be restarted >se STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACII ITV RFPnRT nF PRnnl ICFs r9AS niSPnSITInN 1. Facility Number 1330000081 2. Facility Name 1 Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. MonthNear of Disposition I December 2015 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 18,035 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 339,771 8. Flared or vented 1 hour or less 5 9. Flared or vented more than 1 hour (see instr.) 15 SWANSON RIVER, GAS STORAGE 772803 6.48% SWANSON RIVER, GAS STORAGE 772805 93.52% 10. Pilot and Purge 176 11. Assist Gas 0 12. Fuel gas used in lease operations 16,313 13. Other (see instructions) 0 Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 374,315 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field Other 1570B 211,653 128,118 339,771 Injected into Storage 403,817 Transferred Gas used as Fuel: - Storage Inv. 2,897,504 1 hereby certify that the foregoin is true and correct to the best of my knowledge. Signature Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Cortne Der Phone 713-289-2881 Date 1/152016 1/7-7- 7-11011L Swanson River Storage December-15 AUon ekes to Imrmee RPADaft, O No Fad' o Date Flared Start Time Ending Time End Date planned MCF Description of Flaring Event Volume Excess venting of Tank 22 due to Excess venting necessary until 12/01/2015 124250 1330000081 12/3/2015 11:30:00 14:00:00 12/3/2015 U 4.0 liquid transfer pump could be (allure of liquid transfer pump. restarted. Excess flaring necessary until 12/01/2015 124250 1330000081 12/3/2015 11:30:00 14:00:00 12/3/2015 U 4.6 Excess Oaring due to liquid transfer transfer pump could be pump failure. restarted. Excess venting necessary due to 12/01/2015 124250 1330000081 12/19/2015 18:30:00 20:15:00 12/19/2015 U 20 unscheduled shutdown of Excess venting necessary Compressor due to high lst stage stripper gas could be adjusted. suction pressure. Excess venting due to unscheduled Excess venting necessary until 12/01/2015 124250 1330000081 12/26/2015 0:00:00 12:00:00 12/26/2015 U 2.3 shutdown ofVRU due to over compressor could be safely pressure restarted. Excess venting due to unscheduled Excess venting necessary until 12/01/2015 124250 1330000081 12/27/2015 10:00:00 11:30:00 12/27/2015 U 1.8 shutudown of VRU due to compressor could be safely overpressure. restarted. 35