Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAbout220-024From:Guhl, Meredith D (OGC)
To:"Taylor, Jenna"; "Conklin, Amy A"; "Hobbs, Greg S"
Subject:Expired CRU Permits
Date:Wednesday, May 18, 2022 3:12:31 PM
Hello,
The following Permits to Drill, issued to ConocoPhillips Alaska, have expired under Regulation 20 AAC
25.005 (g). The PTDs will be marked expired in the AOGCC database.
CRU CD4-28, PTD 220-023, Issued 5 May 2020
CRU CD4-28L1, PTD 220-024, Issued 5 May 2020
If you have any questions, please contact me.
Thank you,
Meredith
Meredith Guhl (she/her)
Petroleum Geology Assistant
Alaska Oil and Gas Conservation Commission
333 W. 7th Ave, Anchorage, AK 99501
meredith.guhl@alaska.gov
Direct: (907) 793-1235
CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, contains information from the Alaska Oil and Gas
Conservation Commission (AOGCC), State of Alaska and is for the sole use of the intended recipient(s). It may contain
confidential and/or privileged information. The unauthorized review, use or disclosure of such information may violate state
or federal law. If you are an unintended recipient of this e-mail, please delete it, without first saving or forwarding it, and, so
that the AOGCC is aware of the mistake in sending it to you, contact Meredith Guhl at 907-793-1235 or
meredith.guhl@alaska.gov.
Alaska Oil and Gas
Conservation Commission
333 West Seventh Avenue
Anchorage, Alaska 99501-3572
Main: 907.279.1433
Fax: 907.276.7542
www.aogcc.alaska.gov
Chip Alvord
Drilling Manager
ConocoPhillips Alaska, Inc.
PO Box 100360
Anchorage, AK 99510-0360
Re: Colville River Field, Alpine Oil Pool, CRU CD5-28L1
ConocoPhillips Alaska, Inc.
Permit to Drill Number: 220-024
Surface Location: 449’ FNL, 2958’ FEL, SEC. 18, T11N, R4E, UM
Bottomhole Location: 1416’ FNL, 1685’ FEL, SEC. 05, T10N, R4E, UM
Dear Mr. Alvord:
Enclosed is the approved application for the permit to drill the above referenced development well.
The permit is for a new wellbore segment of existing well Permit No. 220-023, API No. 50-103-20824-
00-00. Production should continue to be reported as a function of the original API number stated
above.
Per Statute AS 31.05.030(d)(2)(B) and Regulation 20 AAC 25.071, composite curves for well logs run
must be submitted to the AOGCC within 90 days after completion, suspension or abandonment of this
well.
This permit to drill does not exempt you from obtaining additional permits or an approval required by
law from other governmental agencies and does not authorize conducting drilling operations until all
other required permits and approvals have been issued. In addition, the AOGCC reserves the right to
withdraw the permit in the event it was erroneously issued.
Operations must be conducted in accordance with AS 31.05 and Title 20, Chapter 25 of the Alaska
Administrative Code unless the AOGCC specifically authorizes a variance. Failure to comply with an
applicable provision of AS 31.05, Title 20, Chapter 25 of the Alaska Administrative Code, or an
AOGCC order, or the terms and conditions of this permit may result in the revocation or suspension
of the permit.
Sincerely,
Jeremy M. Price
Chair
DATED this ___ day of May, 2020.
Sincerely,
5
BOP test pressure to 3500 psig
Annular preventer test pressure to 2500
X
VTL 5/4/20
A waiver is granted to allow the production packer to be placed ~1000' MD above the casing shoe (20 AAC 25.412(b).
5/5/2020
5/5/2020
Type text
WELL PERMIT CHECKLISTCompanyConocoPhillips Alaska, Inc.Well Name:COLVILLE RIV UNIT CD5-28L1Initial Class/TypeDEV / PENDGeoArea890Unit50360On/Off ShoreOnProgramDEVField & PoolWell bore segAnnular DisposalPTD#:2200240COLVILLE RIVER, ALPINE OIL - 120100NA1Permit fee attachedYesASRC-NPR4 is a split lease containing surface location and a portion of the productive interval.2Lease number appropriateYesASRC-AA092344 contains top of prod interval; ASRC-NPR5 contains TD.3Unique well name and numberYesCOLVILLE RIVER, ALPINE OIL - 120100, governed by CO 443C. 239664Well located in a defined poolYesCO No. 443C has no interwell spacing restrictions. Wellbore will be more than 500' 239665Well located proper distance from drilling unit boundaryYesfrom an external property line where ownership or landownership changes.6Well located proper distance from other wellsYesAs planned, well will conform to all spacing requirements.7Sufficient acreage available in drilling unitYes8If deviated, is wellbore plat includedYes9Operator only affected partyYes10Operator has appropriate bond in forceYes11Permit can be issued without conservation orderYes12Permit can be issued without administrative approvalYes13Can permit be approved before 15-day waitNA14Well located within area and strata authorized by Injection Order # (put IO# in comments) (For sNA15All wells within 1/4 mile area of review identified (For service well only)NA16Pre-produced injector: duration of pre-production less than 3 months (For service well only)NA17Nonconven. gas conforms to AS31.05.030(j.1.A),(j.2.A-D)NAConductor set for CD5-2818Conductor string providedNASurface casing will be set for CD5-2819Surface casing protects all known USDWsNA146% excess planned for CD5-2820CMT vol adequate to circulate on conductor & surf csgNA21CMT vol adequate to tie-in long string to surf csgNoProductive interval will be completed with perforated pipe and frac ports22CMT will cover all known productive horizonsYes23Casing designs adequate for C, T, B & permafrostYesRig has steel tanks; all waste to approved disposal wells24Adequate tankage or reserve pitNA25If a re-drill, has a 10-403 for abandonment been approvedYesAnti-collision analysis complete; no major risk failures26Adequate wellbore separation proposedYes27If diverter required, does it meet regulationsYesMax formation pressure is 3477 psig(8.5 ppg EMW); will drill w/ 8.8 ppg EMW28Drilling fluid program schematic & equip list adequateYes29BOPEs, do they meet regulationYesMPSP is 2687 psig; will test BOPs to 3500 psig30BOPE press rating appropriate; test to (put psig in comments)Yes31Choke manifold complies w/API RP-53 (May 84)Yes32Work will occur without operation shutdownYesH2S measures required33Is presence of H2S gas probableNA34Mechanical condition of wells within AOR verified (For service well only)NoH2S has been encountered in Alpine Oil Pool wells drilled from CD5 Pad. H2S measures required.35Permit can be issued w/o hydrogen sulfide measuresYesPlanned mud weights appear adequate to control the operator's forecast of most likely pore pressures36Data presented on potential overpressure zonesNAin the operator's geologic prognosis. No abnormally geo-pressured strata are anticipated. Managed37Seismic analysis of shallow gas zonesNAPressure Drilling technique and higher mud weights will be used to maintain borehole stability in shale38Seabed condition survey (if off-shore)NAsections.39Contact name/phone for weekly progress reports [exploratory only]ApprSFDDate3/6/2020ApprVTLDate5/4/2020ApprSFDDate3/6/2020AdministrationEngineeringGeologyGeologic Commissioner:Date:Engineering Commissioner:DatePublic CommissionerDateDaniel T. Seamount, Jr.Digitally signed by Daniel T. Seamount, Jr. Date: 2020.05.04 15:03:31 -08'00'JMP 5/5/2020JLC 5/4/2020