STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED ros rnSpnc1T1nN
1. Facility Number 2. Facility Name
0290000030 PBU FS 3
Disposition
3. Field
PBU - EOA
Volume MCF
4. Operator •5. Month/Year of Disposition
BID Janua -2016
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name Pool Code Percent
7. Reinjected
0
PRUDHOE 640150 100.00%
8. Flared or vented 1 hour or less
3
9. Flared or vented more than 1 hour (see instr.)
86,475
10. Pilot and Purge
42,305
11. Assist Gas
135,306
12. Fuel gas used in lease operations.
952,856
13. Other (see instructions)
0Official
Use Only
Authorization >1 he
Safety
�� !t
7)x—
MCF
14. TOTAL VOLUME (ITEMS 6-12)
1,216,945
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from: CGF
995,161
— /s _/fo
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-29,687,032
19. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected
Q�0*4
Signature Title Mana er Production Taxes and Royalties Alaska to pressure Of 14.65 Asia and to a
temperature of 60o F. Authority 20
Printed Name Diane Colley Phone (907) 564-5775 Date AAC25.235.
v/7-1-
41t5114
1-
41t5!!G
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
1/16-29/16 1100-1800 86,475 See attachments See attachments •^ ��V�c
TOTAL 86,475
Planned Events Less Than or Equal 1 Hour AND <= 5.000 mcf
See attachments
TOTAL 0
Events Exceeding 1 Hour OR >
See attachments
TOTAL
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - FS -3
Unplanned Events < 1 Hour
GAS FLARING INCIDENT REPORT
Unplanned Events> 1 Hour
January 2016
Unplanned Events less than or equal to 1 hour
0
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
1/16/2016 1100-1105
3 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr
TOTAL
3
1/16-29/16 1100-1800 86,475 See attachments See attachments •^ ��V�c
TOTAL 86,475
Planned Events Less Than or Equal 1 Hour AND <= 5.000 mcf
See attachments
TOTAL 0
Events Exceeding 1 Hour OR >
See attachments
TOTAL
0
TOTAL
Unplanned Events < 1 Hour
3
Unplanned Events> 1 Hour
86,475
Planned Events < 1 hour and not
0
exceeding 5,000 MCF
Planned Events> 1 hour or
0
exceeding 5,000 VICE
Pilot Purge
42,305
Assist
135,306
TOTAL FLARED VOLUME
264,089
See attachments
See attachments
Page 5
2/12/2016
2:27 PM
bp
Certified Mail: 7015 0640 0006 6000 0733 'T`
February 2, 2016
Commissioner Catherine Foerster
State of Alaska
Alaska Oil and Gas Conservation Commission
333 West 7`h Ave., Ste. 100
Anchorage, AK 99501-3539
Subject: Notice of Elevated Flaring at Flow Station 3
Dear Commissioner Foerster:
BP Exploration (Alaska) Inc.
900 East Benson Boulevard
P.O. Box 196612
Anchorage, Alaska 99519-6612
(907)561-5111
RECEIVED
FEB 0 5 2016
AOGCC
BP Exploration (Alaska) Inc. (BPXA), as operator of the Prudhoe Bay Unit (PBU), is writing to notify
The Alaska Oil and Gas Conservation Commission (AOGCC) of the elevated flaring at Flow Station 3
(FS3) that began January 16, 2016 at approximately 11:00 am and ended on January 29 at
approximately 6:00 p.m. The total volume of gas flared was 86476 MMSCF. The flaring occurred as
part of an operational condition due to the failure of the 1802 turbine that drives the single Stock Tank
Vapor - Intermediate Pressure (STV -IP) compressor.
The 1801 turbine had previously been removed from service at FS3 as part of an optimization project
to replace the two LM -1500 units with one new single -train motor (electric) driven centrifugal
compressor. Due to the removal of this unit in preparation for the installation of the electric
compressor, there is not currently any redundancy. Therefore, flaring the STV -IP gas stream was
necessary to maintain stable facility operations at FS3 during the turbine failure investigation and
follow-up actions to repair the system. The only other alternative to flaring would have been to shut
down major equipment and operations at FS3, which would have introduced unacceptable process
and operational risks given the winter temperatures and dangers associated with freezing lines,
wells, vessels etc.
BPXA made every reasonable effort to minimize flaring at FS3 during the STV -IP compressor outage
and repair, consistent with maintaining safe and reliable operations and in accordance with good oil
field engineering practices. BPXA respectfully requests that the AOGCC recognize the flaring activity
was necessary for facility operations, repairs or upgrades, and not waste, under 20 AAC 25.235(d).
Sincerely,
a4Y7 *ta�
TEastea perations Manager
BP Exploration (Alaska) Inc.
L� O pY
Link, Liz M (DOA)
From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent: Wednesday, January 27, 2016 8:53 AM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; AK, OPS GC3&PCC OSM;
Martin, Nelson D; AK, HSSEE Env Adv East; AK, OPS FS3 Facility OTL; Glover, Robin (SLR);
Kain, Rachel B; AK, OPS FS3 OSM
Subject: Flaring Event at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
AOgCC.repOrtinq(, alaska.goy Victoria. loepq(a7.a18Ska.gOv
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 01/24/2016 00:00 and stopping at 01/25/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/25/2016 00:00 and stopping at 01/26/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/26/2016 00:00 and stopping at 01/27/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STVAP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
I will provide rolled up flare event reports every few days.
Thanks,
Jennifer Blake
PCC/EOC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell (907) 830-6204
Jennifer.blake@bp.com
Link, Liz M (DOA)
From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent: Sunday, January 31, 2016 8:42 AM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, AK, OPS GC3&PCC CSM;
Martin, Nelson D; AK, HSSEE Env Adv East; AK, OPS FS3 Facility OTL; Glover, Robin (SLR);
Kain, Rachel B; AK, OPS FS3 OSM
Subject: Flaring Event at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
Aoocc.reporting(Walaska.gov Victoria. loepi)()alaska.gov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 01/27/2016 00:00 and stopping at 01/28/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues. Path forward is to install the spare FS 1 Gas Generator turbine at FS3 to get the STV/IP
back online.
A flaring event occurred at FS3 starting at 01/28/2016 00:00 and stopping at 01/29/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues. Path forward is to install the spare FSI Gas Generator turbine at FS3 to get the STV/IP
back online.
A flaring event occurred at FS3 starting at 01/29/2016 00:00 and stopping at 01/29/2016 18:00 with a volume of
4875 (MSCF). The event lasted for 1080 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. The event
stopped when the Gas Generator turbine from FS1 was reconnected and the FS3 1802 compressor train was
started up.
Thanks,
Jennifer Blake
PCC/EOC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell (907) 830-6204
Jennifer. blake@bp.com
Link, Liz M
From:
Sent:
To:
Cc:
Subject:
AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sunday, January 24, 2016 2:13 PM
AOGCC Reporting (DOA sponsored)
Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; AK, OPS GC3&PCC OSM;
Martin, Nelson D; AK, HSSEE Env Adv East; AK, OPS FS3 Facility OTL, Glover, Robin (SLR);
Kain, Rachel B; AK, OPS FS3 OSM
Flaring Event at FS3
To: AOGCC Reporting
Aogcc reporting(aalaskagov
CC: Victoria Loepp, AOGCC
Victoria loepp(cDalaskagov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 01/16/2016 11:00 and stopping at 01/16/2016 23:59 with a volume of
3600 (MSCF). The event lasted for 779 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/17/2016 00:00 and stopping at 01/18/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/18/2016 00:00 and stopping at 01/19/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/19/2016 00:00 and stopping at 01/20/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/20/2016 00:00 and stopping at 01/21/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/21/2016 00:00 and stopping at 01/22/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/22/2016 00:00 and stopping at 01/23/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
A flaring event occurred at FS3 starting at 01/23/2016 00:00 and stopping at 01/24/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to Flaring STV and IP gas due to 1802 STV/IP
compressor malfunction and inability to compress these gases to get into the residue gas train. Still flaring as
investigation continues with path forward
I will provide rolled up flare event reports every few days.
Thanks,
Jennifer Blake
PCC/EOC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell (907) 830-6204
Jennifer.blake@bp.com
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY RFPnRT nF [)anry IP%Cn n A � r%1^ii% w. .....
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - FS -3
GAS FLARING INCIDENT REPORT
February 2016
Not required for unplanned events <= 1 hr
TOTAL 0
Events greater than 1 hour
See attachments
TOTAL 0
Events Less Than or Equal 1 Hour AND <_!
See attachments
TOTAL 0
See attachments
TOTAL 0
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 6
3/11/2016
3:27 PM
TOTAL
Unplanned Events < 1 Hour
0
Unplanned Events> 1 Hour
0
Planned Events < 1 hour and not
exceeding 5,000 MCF
0
Planned Events > 1 hour or
exceeding 5,000 MCF
0
Pilot Purge
39,651
Assist
140
TOTAL FLARED VOLUME
39,791
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 6
3/11/2016
3:27 PM
Link, Liz M
From:
Sent:
To:
Cc:
Subject:
AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sunday, March 13, 2016 6:46 PM
AOGCC Reporting (DOA sponsored)
Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, AK, OPS GC3&PCC OSM;
Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM;
Glover, Robin; Kain, Rachel B
Flaring Event at GC1
To: AOGCC Reporting
Aogcc reoorting(d)alaska qov
CC: Victoria Loepp, AOGCC
Victoria loepp@alaska.gov
From: David Spall, GPB Production Optimization Team Leader
A flaring event occurred at GC 1 starting at 02/26/2016 00:00 and stopping at 02/26/2016 23:59 with a volume
of 5 (MSCF). The event was Intermittent. The event was due to The LP Flare valve FV-608UC was open
intermittently for a total cumulative time of 25 minutes in the 24 hour period. This flaring event is related to the
Flare system purge rate and cannot be avoided.
A flaring event occurred at GC 1 starting at 03/5/2016 00:00 and stopping at 03/5/2016 23:59 with a volume of 7
(MSCF). The event was Intermittent. The event was due to The LP Flare valve FV-608UC was open
intermittently for a total cumulative time of 25 minutes in the 24 hour period. This flaring event is related to the
Flare system purge rate and cannot be avoided.
A flaring event occurred at GCI starting at 03/6/2016 00:00 and stopping at 03/6/2016 23:59 with a volume of
17 (MSCF). The event was Intermittent. The event was due to The LP Flare valve FV-608UC was open
intermittently for a total cumulative time of 60 minutes in the 24 hour period. This flaring event is related to the
Flare system purge rate and cannot be avoided.
A flaring event occurred at GCI starting at 03/7/2016 00:00 and stopping at 03/7/2016 23:59 with a volume of
17 (MSCF). The event was Intermittent. The event was due to The LP Flare valve FV-608UC was open
intermittently for a total cumulative time of 60 minutes in the 24 hour period. This flaring event is related to the
Flare system purge rate and cannot be avoided.
A flaring event occurred at GC 1 starting at 03/8/2016 00:00 and stopping at 03/8/2016 23:59 with a volume of
14 (MSCF). The event was Intermittent. The event was due to The LP Flare valve FV-608UC was open
intermittently for a total cumulative time of 50 minutes in the 24 hour period. This flaring event is related to the
Flare system purge rate and cannot be avoided.
A flaring event occurred at GCI starting at 03/11/2016 14:00 and stopping at 03/11/2016 19:30 with a volume
of 70833 (MSCF). The event lasted 330 minutes. The event was due to a complete power loss and shutdown at
CGF, which caused high transit gas pressure. The flaring event was stopped from cutting rate on wells across
the entire GP13 field, all well pads and Drill sites were cut back on rate to lower the transit Gas pressure and
CGF got started back up.
Thanks,
David Spall
PCC/EOC Production Optimization Team Lead (Alt Jennifer Blake)
Office 907-659-4472
Cell 219-689-4036
David.spall@bp.com
Link, Liz M (DOA)
From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent: Tuesday, February 23, 2016 1:19 PM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; AK, OPS GC3&PCC OSM;
Barton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL, AK, OPS GCI OSM;
Glover, Robin; Kain, Rachel B
Subject: Feb 2016 Flaring Event at GC1
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
Aogcc.reporting(c alaska.00v Victoria. loepl) a.alaska.gov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at GCI starting at 02/15/2016 14:23 and stopping at 02/15/2016 15:06 with a volume
of 10 (MSCF). The event was due to a plant upset that resulted in flaring off the LP and HP flare. The event
stopped when rate was cut and the plant normalized.
Thanks,
Jennifer Blake
PCC/EOC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell (907) 830-6204
Tennifer.blake@bp.com
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
acility Name 3.Fieltl
J FS 3
6,
Sold
Safety
0
7.
Reinjected
MCF
Conservation
0
8.
Flared or vented 1 hour or less
WE
333
9.
Flared or vented more than 1 hour (see instr.)
tion Taxes and Ro alties Alaska to pressure of 14.65 Asia and to a
temperature of 600 F. Authority 20
Date '
AAC25.235.
20,416
10.
Pilot and Purge
42,899
11.
Assist Gas
1,078
12.
Fuel gas used in lease operations.
1,018,549
13.
Other (see instructions)
0
14.
TOTAL VOLUME (ITEMS6-12)
1,083,275
15.
NGL Gas Equivalent
0
16.
Purchased gas
0
17.
Transferred from: CGF
1,061,447
18.
Transferred to: (Express as a negative #) CGF
-29,200,317
19.
Remarks:
correct to
Name Diane
Form 10-422 Rev. 5/2009
my
I March -201
20. For production from multiple pools, hst contnbuticn of each pool as a
Total Volume.
Authorization>i hr
Safety
MCF
Lease Use
MCF
Conservation
MCF
Waste:
WE
Commissioner Date
Note: All Volumes must be corrected
tion Taxes and Ro alties Alaska to pressure of 14.65 Asia and to a
temperature of 600 F. Authority 20
Date '
AAC25.235.
INSTRUCTIONS ON REVERSE SIDE
L'T L
Ad
,moi( -T
Submit in Duplicate
nned events less than or eaual to i hour
See attachments See attachments
TOTAL 0
See attachments See attachments
TOTAL 0
BP EXPLORATION (ALASKA) INC.
Unplanned Events < 1 Hour
PRUDHOE BAY UNIT - FS -3
333
Unplanned Events > 1 Hour
GAS FLARING INCIDENT REPORT
20,416
March 2016
Page 5
1planned events less than or equal to 1 hour
0
DATE TIME
3/20/2016, 0625-0630
VOLUME DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
3/20/2016 0700-0705
80 Not required for unplanned events <= 1 hr
Not required for unplanned events <= 1 hr
3/20/2016 0715-0720
80
80
Assist
3/20/2016 0730-0735
80
1,078
3/23/2016 1455-1511
11
3/23/2016 1550-1552
2
4/14/2016
TOTAL
333
planned events greater than 1 hour
DATE TIME
3/20/2016 0630-0800
VOLUME DESCRIPTION OF INCIDENT & CAUSE
20,416 See attachments
ACTION TAKEN TO ELlMINAT€ CAUSE
See attachments
TOTAL
20,416
nned events less than or eaual to i hour
See attachments See attachments
TOTAL 0
See attachments See attachments
TOTAL 0
TOTAL
Unplanned Events < 1 Hour
333
Unplanned Events > 1 Hour
20,416
Planned Events <1 hour and not
exceeding 5,000 MCF
0
Planned Events > 1 hour or
exceeding 5,000 MCF
0
Pilot Purge
42,899
Assist
1,078
TOTAL FLARED VOLUME
64,726
4/14/2016
1:52 PM
GAS nlSPnslTln Ki IMDnpT cr'�ou
R tDate
/01/2016
0390000008
03/01/2016
03/Ot/2D16
03/01/2016
O No
112300
11230 0
112300
112300
-Facili No
02
0 290000008
0290000008
0290000029
-
Date Flared
03/11/2016
03/12/2016
03/30/2016
03/08/2016
-- —•
Start Time
14:11
00:01
12:57
13:30
""' --•
Endin Time
15:45
14:28
15:01
19:41
..11111 1�m
End Date
03/11/2016
03/12/2016
03/30/2016
03/09/2016
rte.
Planned
U
U
U
U
MJIMu
MCF
88000
30796
17202
7408
tvtly f J GKEATER THAN 1 HOUR
Desch tion of Flarin Event
Power loss caused !ant blow down.
Plant shutdown due to ower loss.
TC 1805 MI 1 Shutdown on control problem/
rec H. tri
C for
maintenadnce/1801own 1PIrecycle valve actuator
leak
Taken to Minimize Volume
Plan[ dAction
started !ant and Flare valves closed.
Repaired and restarted MI Compressor T/C
1805
IP Anti -Surge Actuator failed, Loaded SN/IP
T/C.
Loaded STVAP T/C.
Repairs made and associated equipment back
online.
Started 1801
Product IP /
03/01/2016
112300
0290000029
03/11/2016
14:26
21:0003/11/2016
U
1395
STV -P T�C 1801 shutdown due to a
associated with CGF losing power and them
front end of their plant pressuring up.
Depredssured commonlines 9E, 11A, antl
11 D to com fete lace ssa work.
TIC shutdown for planned maintenance/
1801 4000hr ins action
T\C 1801 shutdown for planned
Flaritne due o 1803 un lanned shutdown.
The LP Flare
nterm ttently forlatotal cumulative time of 25ystem
03/01/2016
03/01/2016
03/01/2016
03/01!2016
03/01/2016
112300
112300
112300
112300
112300
0290000029
0290000029
0290000029
0290000030
0290000031
03/01/2016
03/03/2016
03/11/2016
03/20/2016C.
03/05/2016
02:48
02:30
10:12
06:30
00:00
06:15
09:00
11:55
08:00
24:00
03/01/2016
03/08/2016
03/11/2016
03/20/2016
03/08/2016
P
P
P
U
U
400
36885
500
20416
55
Cut Production to keep out of flare.
This flaring event is related to the Flare s
minutes in the 24 hour eriod
Purge rate and cannot be avoided
03/01/2016
112300
0290000031
03/11/2016
14:00
19:30
03/11/2016
U
70833
High gas transit line pressure caused by
CGF compressor problems due to s/d
Although isback
LP IP gas oil
cormpress onrsystem sP of he
tlesi ned for toda 's as conditions
Eoa and woa cut rates antl flared to retluce
transitline pressure until cgf started machine
u
Waiting for rates to stabilize
03/01/2016
112300
0290000031
03/2712016
00:01
-
24:00
-
03/27/2016
U
287
03/01/2016
112300
0290000031
03/29/2016
00:00
24:00
03/29/2016
U
135
Alt
LP/IPugas compression gh oil rate is rsys em sp of he
designed for today's gas conditions
Waiting for rates to stabilize
This Excel spreadsheet has column headings and data formatting to import flaring events over one hour into the AOGCC database. Copy and paste the headings into an Excel sheet and enter all
flaring events over one hour for the month under the appropriate columns per instructions below. One operator can enter all events from all associated facilities.
mm/01/yyyy Use first day of the month.
Directions
R tDate
O No
Six digits. See list of operators inn column. Operator Names Operator Numbers
Ten digits. On form 10-422 or call (907) 793-1241. AURORA GAS LLC 110800
mm/rid/y...... BP EXPLORATION ALASKA INC 112300
Military time: 0000t02 MARATHON OIL CO 129000
Militarytime: 00:00 to 23:59 NORTH SLOPE BOROUGH 131300
mm/dd/yyyy PACIFIC ENERGY RESOURCES LTD 131900
"U" for unplanned event or "P" for planned event. CONOCOPHILLIPS ALASKA INC 134200
Flared gas amount in MCF. NO DECIMALS. PIONEER NATURAL RESOURCES ALAS 135300
TECK COMINCO ALASKA INCORPORATE 141200
UNION OIL CO OF CALIFORNIA 145000
Facili No
Date Flared
Start Time
Endin Time
End Date
Planned
MCF
XTO ENERGYINC 146700
Revised 7/2009
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY RFPr)DT no omf%mi
Form 10-422 Rev, 5/2009
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
See attachments
TOTAL 0
nned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF IN
4/15/2016 1252-1319 446 See attachments
TOTAL 446
See attachments
TOTAL 0
TOTAL
Unplanned Events < 1 Hour
BP EXPLORATION IALASKAI INC.
Unplanned Events> 1 Hour
PRUDHOE BAY UNIT - FS -3
Planned Events < 1 hour and not
exceeding 5,000 MCF
GAS FLARING INCIDENT REPORT
Planned Events > 1 hour or
exceeding 5,000 MCF
April 2016
iplanned events less than or equal
to 1 hour
ASSIST
DATE
4/25/2016
TIME
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
0100-0110
60
Not required for unplanned events <= 1 hr
4/25/2016
0130-0140
60
4/25/2016
0130-0140
3
4/26/2016
0730-0740
60
TOTAL
183
See attachments
TOTAL 0
nned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF IN
4/15/2016 1252-1319 446 See attachments
TOTAL 446
See attachments
TOTAL 0
Not required for unplanned events <= 1 hr
Al I IUN TAKEN TO E
See attachments
See attachments
See attachments
Page 8
5/16/2016
3:44 PM
TOTAL
Unplanned Events < 1 Hour
183
Unplanned Events> 1 Hour
0
Planned Events < 1 hour and not
exceeding 5,000 MCF
446
Planned Events > 1 hour or
exceeding 5,000 MCF
0
Pilot Purge
41,311
ASSIST
1,474
TOTAL FLARED VOLUME
43,414
Not required for unplanned events <= 1 hr
Al I IUN TAKEN TO E
See attachments
See attachments
See attachments
Page 8
5/16/2016
3:44 PM
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY RFPnRT nP DDnni lf'=F%
Form 10-422 Rev. 5/2009
INSTRUCTIONS ON REVERSE SIDE
VTL
Submit in Duplicate
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT- FS -3
GAS FLARING INCIDENT REPORT
May 2016
5/17/2016 Z""'Irory UP INCIDENT & CAUSE
/ 2030-2040 240 Not required for unplanned events <= 1 hr
TOTAL 240
See attachments
TOTAL
0
Planned events less than or equal to 1 hour
OATS TIME
5/13/2016
VOLUME DESCRIPTION OF IN(
1840-1850
5/26/2016
240 See attachments
0050-0055
60
5/26/2016 0300-0305
60
5/28/2016 2255-2300
60
TOTAL
420
Planned events greater than 1 hour
DATE TIME
5/17/2016
VOLUME DESCRIPTION OF INCI
1340-1510
402 See attachments
5/26/2016 0100-0300
472
5/28/2016
/ 1500-1615
416
5/30/2016 1500-1630
312
TOTAL
1,602
unplanned Events < 1 Hour
TOTAL
zaD
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
exceeding 5,000 MCF
420
Planned Events > 1 hour or
exceeding 5,000 MCF
1,602
Pilot Purge
43,071
Assist
4,432
TOTAL FLARED VOLUME
,765_
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 6
6/15/2016
2:44 PM
Liz M
From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent: Wednesday, May 18, 2016 9:32 AM
To: AOGCC Reporting (DOA sponsored)
Cr Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; AK, OPS GC3&PCC OSM;
Martin, Nelson D; AK, HSSEE Env Adv East; AK, OPS FS3 Facility OTL, Glover, Robin; Kain,
Rachel B; AK, OPS FS3 OSM
Subject: Flaring Event at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aogcc reoortingCQalaskagov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 05/17/2016 13:40 and stopping at 05/17/2016 15:10 with a volume of 402
(MSCF). The event lasted for 90 minutes and was due to shutdown of the 1806 turbine for water wash. The event
stopped when the water wash crank of the turbine was completed.
Thanks,
Jennifer Blake
PCC/EOC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell (907) 830-6204
Jennifer blakePbp com
Link, Liz M
From:
AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent:
Thursday, June 09, 2016 9:17 AM
To:
AOGCC Reporting (DOA sponsored)
Cc:
Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, AK, OPS GC3&PCC OSM;
Martin, Nelson D; AK, HSSEE Env Adv East; AK, OPS FS3 Facility OTL; Glover, Robin;
Buckbee, Rachel A; AK, OPS FS3 OSM
Subject:
Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aogcc reoorting(o)alaskagov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 05/26/2016 01:00 and stopping at 05/26/2016 03:00 with a volume of 472
(MSCF). The event lasted for 120 minutes and was due to shutdown of the 1803 turbine for planned maintenance/water
wash. The event stopped when the spin cooling of the turbine was completed.
A flaring event occurred at FS3 starting at 05/28/2016 15:00 and stopping at 05/28/2016 16:15 with a volume of 416
(MSCF). The event lasted for 75 minutes and was due to spinning the 1803 turbine for water wash. The event stopped
when the water wash was completed.
A flaring event occurred at FS3 starting at 05/30/2016 15:00 and stopping at 05/30/2016 16:30 with a volume of 312
(MSCF). The event lasted for 90 minutes and was due to spinning the 1804 turbine for water wash. The event stopped
when the water wash was completed.
Thanks,
Jennifer Blake
PCC/ECIC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell (907) 830-6204
Jennifer.blake@bp.com
Flare Start Date 05/01/2016
Flare End Date 05/31/2016
FS3 Flare Report
Total Volume (MSCF) 2262
Report
Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
�-��� wneonea niowcown u5113/2016 6:40:OOpm 6:50:00 pm 10 min No No Yes BP1\DONATR 240
Determination Cause Normal Shutdown of 1806 case depressurization potential due to turbine combustion crossover tube issues.
Action Taken Completed the shutdown sequence.
Daily Volume (MSCF) 240
16-163 Controlled Slowdown 05/17/2016 1:40:00 pm 3:10:00 pm 90 min No No Yes BPi\DONATR 402
Determination Cause 1806 water wash crank.
Action Taken Completed the water wash crank of the turbine.
16-169 Controlled Blowdown 05/26/2016 12:50:00 am 12:55:00 am 5 min No No Yes BPi\WELBORD 60
Determination Cause TC 1803 shutdown for planned maintenance/waterwash
Action Taken Completed shutdown.
16-169 Controlled Blowdown 05/26/2016 1:00:00 am 3:00:00 am 120 min No No Yes BP7\WELSORD 472
Determination Cause TC 1803 spin cooling
Action Taken Completed spin cooling.
ra-ta9 Controlled Blowdown 05/26/2016 3:00:00 am 3:05:00 am 5min No
Determination Cause TC 1803 shutdown for planned maintenance/waterwash
Action Taken Completed shutdown.
16-173 Controlled Blowdown 05/28/2016 3:00:00 pm 4:15:00 pm 75 min No
Determination Cause 1803 spinning for water wash
Action Taken completed water wash
No Yes BP7\WELSORD 60
Daily Volume (MSCF) 592
No Yes BPMELSORD 416
10-1t3 Controlletl Blowdown 05/28/2016 10:55:00pm 11:00:OO pm 5 min No No Yes BP1\WELBORD 60
Determination Cause TC 1804 shutdown for planned maintenance
Action Taken Completed shutdown.
Daily Volume (MSCF) 476
16-177 Controlled Blowdown 05/30/2016 3:00:00 pm 4:30:00 pm 90 min No No Yes BPMELBORD 312
Determination Cause 1804 spinning for water wash
Action Taken completed 1804 water wash
Daily Volume (MSCF) 312
Total Volume (MSCF) 2262
sled 06/07/2016 4:33:28PM
Page 6 of 9
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
acility Name 3. Field
J FS 3 PB U - EOA Do0perator 5
NhIe
ld
injected
red or vented 1 hour or less
red or vented more than 1 hour (see instr.)
lot and Purge
sist Gas
el gas used in lease operations.her (see instructions)TAL VOLUME (ITEMS 6.12)L Gas Equivalent.chased gas
17. Transferred from: CGF
18. Transferred to: (Express as a negative #) CGF
19. Remarks:
the foregoing is
Form 10-422 Rev, 512009
For production from
38,067
42,9E
821,51
I June -2016
701s, list contnbution of each pool as a F
Total Volume.
Safety rvn,r V?"
(Lease Use IMCF
86Q 17C
-16,751,719
Title Note: Manager Production Taxes and Ro allies Alaska Note: All volumes must
to pressure Of 14.65 psis ia andnd to to a a
Phone (907 //
564-5775 Date / temperature of 600 F. Authority 20
) --1 � Q /, L-.
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
BP EXPLORATION IALASKAI INC.
PRUDHOE BAY UNIT- FS -3
GAS FLARING INCIDENT REPORT
June 2016
planned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
6/12/2016 1200-1210 60 Not required for unplanned events <= 1 hr
6/12/2016 1620-1630 60
TOTAL 120
planned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF IN
6/12/2016 1200-1314 12,847 See attachments
6/12/2016 1420-1620 942
TOTAL 13,789
nned events less than or equal to 1 hour
See attachments
Unplanned Events < 1 Hour 120
Unplanned Events > 1 Hour 13,789
Planned Events < 1 hour and not 0
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
24,278
38,655
42,964
119,806
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 6
7/18/2016
3:41 PM
TOTAL
p
coned events greater than 1 hour
DATE
TIME
VOLUME DESCRIPTION OF INI
6/15-17/16
0300-1415
16,047 See attachments
6/25/2016
0500-0700
8,231
TOTAL
24,278
TOTAL
Unplanned Events < 1 Hour 120
Unplanned Events > 1 Hour 13,789
Planned Events < 1 hour and not 0
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
24,278
38,655
42,964
119,806
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 6
7/18/2016
3:41 PM
Flare Start Date 06/01/2016
Flare End Date 06/3012016
FS3 Flare Report
Total Volume (MSCF) 38187
Report
Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
18-199Controlled Blowdown 06/12/2016 12:00:00 pm 1:14:00 pm 74 min No Yes
No BP1 \DONATR
12547
Determination Cause 1803 LPS TC shutdown due to a bad analog card. Flared from Slugcatchers.
Action Taken Shut in production until flaring stopped from Slugcatchers. Black smoked from the 5th stage
for about 35 minutes.
16-199 Controlled Blowdown 06/12/2016 2:20:00 pm 4:20:00 pm 120 min No No
No BP1\DONATR
942
Determination Cause 1803 TC Crank to cool down turbine to allow the control power to be turned off to repair the Analog Card,
Action Taken Completed the Crank cool down.
16-205 Flare Relief 06/15/2016 3:00:00 am 11:59:00 pm 1259 min No No
Yes BP1\BOUWKA
5687
Determination Cause 1802 COS for 4000 hour replacement
Action Taken None, still flaring
Daily Volume (MSCF)
5687
16-203 Flare Relief 06/16/2016 12:01:00 am 11:59:00 pm 1438 min No No
Yes BP1\BCUWKA
6500
Determination Cause 1802 COS for 4000 hour replacement, plus IGV issues during startup
Action Taken None, still flaring
Daily Volume (MSCF)
6500
16-206 Flare Relief 06/17/2016 12:00:00 am 2:15:00 pm 855 min No No
Yes BP1\WELBORD
3860
Determination Cause 1802 COB for 4000 hour replacement, plus IGV issues during startup
Action Taken Corrected the IGV issues and restarted 1802
Daily Volume (MSCF)
3860
16-217 Flare Relief 06/25/2016 5:00:00 am 7:00:00 am 120 min No No
Yes BP7\BOUWKA
8231
Determination Cause Assisted de -pressuring A/L header from FS3 to FS2 drill sites for line lifts
Action Taken Achieved under 500# desired pressure
Daily Volume (MSCF)
8231
Total Volume (MSCF)
38167
07/06/2016 1:44:03PM
Page 6 Of 11
Liz M
From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent: Monday, June 13, 2016 4:35 PM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, AK, OPS GC3&PCC OSM;
Martin, Nelson D; AK, HSSEE Env Adv East; AK, OPS FS3 Facility OTL; Glover, Robin;
Buckbee, Rachel A; AK, OPS FS3 OSM
Subject: Flaring Events at FS3
To AOGCC Reporting CC: Victoria Loepp, AOGCC
a0gcc reoorting(c)alaskagov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 06/12/2016 14:20 and stopping at 06/12/2016 16:20 with a volume of 942
(MSCF). The event lasted for 120 minutes and was due to shutdown of the 1803 turbine shutdown after the crank cool
down with subsequent compressor case blow down. The event stopped when the blowdown sequence was completed.
Thanks,
Jennifer Blake
PCC/EOC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell(907)830-6204
Jennifer.blake61bp com
Link, Liz M
From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent: Thursday, July 07, 2016 1:46 PM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Martin, Nelson D; AK, HSSEE
Env Adv East, AK, OPS FS3 Facility OTL, Glover, Robin; Buckbee, Rachel A; AK, OPS FS3
OSM
Subject: Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aogcc reoortino()alaska qoy
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 06/12/2016 12:00 and stopping at 06/12/2016 13:14 with a volume of 12847
(MSCF). The event lasted for 74 minutes and was due to a 1803 LPS TC shutdown caused by a bad analog card. The
flaring event stopped when enough production was shut in to stop flaring from the slug catcher.
A flaring event occurred at FS3 starting at 06/12/2016 14:20 and stopping at 06/12/2016 16:20 with a volume of 942
(MSCF). The event lasted for 120 minutes and was due to 1803 LPS TC crank cool down of the turbine to allow the
control power to be turned off to fix the analog card. The flaring event stopped when the crank cool down was
completed.
A flaring event occurred at FS3 starting at 06/25/2016 05:00 and stopping at 06/25/2016 07:00 with a volume of 8231
(MSCF). The event lasted for 120 minutes and was due to depressurization of the Artificial Lift header from FS3 to FS2
drill sites for line lifts. The flaring event stopped when pressures dropped below the target 500 psig pressure for line lifts.
Thanks,
Jennifer Bloke
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell(907)830-6204
Jennifer.blake@bo com
Link, Liz M (DOA)
From:
AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com>
Sent:
Thursday, lune 23, 2016 3:29 PM
To:
AOGCC Reporting (DOA sponsored)
Cc:
Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, AK, OPS GC3&PCC OSM;
Martin, Nelson D; AK, HSSEE Env Adv East; AK, OPS FS3 Facility OTL; Glover, Robin;
Buckbee, Rachel A; AK, OPS FS3 OSM
Subject:
Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aogcc reoorting(a)alaska aov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 06/15/2016 03:00 and stopping at 06/15/2016 23:59 with a volume of 5687
(MSCF). The event lasted for 1259 minutes and was due to taking STV/IP Compressor 1802 out of service for the 4000
hour replacement. The flaring event continued into the next day.
A flaring event occurred at FS3 starting at 06/16/2016 00:01 and stopping at 06/16/2016 23:59 with a volume of 6500
(MSCF). The event lasted for 1438 minutes and was the continuation of the 4000 hour replacement work for STV/IP 1802
as well as IGV issues during start up. The flaring event continued into the next day.
A flaring event occurred at FS3 starting at 06/17/2016 00:00 and stopping at 06/17/2016 14:15 with a volume of 3,860
(MSCF). The event lasted for 855 minutes and was due to the continuation of the STV/IP 1802 IGV issues upon restart.
The flaring event stopped when the IGV issues were corrected and 1802 was restarted.
Thanks,
Jennifer Blake
PCC/EOC Production Optimization Team Lead (alt David Spall)
Office (907) 659-4472
Cell(907)830-6204
Jennifer.blakeC)a ke@bp.com
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY RFPr)PT nC 00nni v+r!r,
Form 10-422 Rev. 5/2009
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
planneo events less than or
DATE
TIME
7/22/2016
1100-1130
7/23/2016
1643-1710
7/20/2016 2000-2320
TOTAL
events
TOTAL
nned events less than or eqi
DATE TIME
7/9/2016 0730-0815
TOTAL
to 1
1 hour
to 1 hour
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT- FS -3
GAS FLARING INCIDENT REPORT
July 2016
47 Not required for unplanned events <= 1 hr
150
197
See attachments
0
84 See attachments
84
7/7/2016 1130-1300
---.-._ Ur IN
96 See attachments
7/8/2016 0745-1100
98
7/8/2016 1240-1500
17
7/20/2016 2000-2320
4,435
TOTAL
4,646
TOTAL
Unplanned Events < 1 Hour
197
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
exceeding 5,000 MCF
84
Planned Events> 1 hour or
exceeding 5,000 MCF
4,646
Pilot Purge
35,819
Assist
168
TOTAL FLARED VOLUME
40,914
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 5
8/11/2016
9:46 AM
flareStartDate 07/01/2016
Flare End Date 07/31/2016
Report
FS3 Flare Report
Total Volume (MSCF)
4927
Numbs System Date Start Time Stop Time Duration Intermittent
16-234 Flare Relief 07/07/2016 11:30:00 am 1:00:00 pm 90 min No
Determination Cause 6D CL was depressured to flare for installation of temporary pigging kit.
Black Smoke Planned Reported By
No Yes 8P1\DONATR
Volume
96
Action Taken
Completed the depressurization of 6D CL.
16-235 Flare Relief 07/08/2016 7:45:00 am 11:00:00 am 195 min No
Determination Cause 6D CL depressured for temporary pigging kit installation.
No Yes BPIIDONATR
gg
Action Taken
Completed the depressurization of 6D CL.
16-235 Flare Relief 07/08/2016 12:40:00 pm 3:00:00 pm 140 min No No Yes BP7\DONATR
Determination Cause 6D CL depressured after completing a pressure build up test for the temporary pig kit installation.
17
Action Taken
Completed the depressurization of the 6D CL.
16-236 Flare Relief 07/09/2016 7:30:00 am 8:15:00 am 45 min No
No Yes BP1\DONATR 84
Determination Cause 6D CL tlepresssuretl for pig receiverinstallation.
Action Taken Completed the depressurization of the 6d CL.
16-244 Flare Relief 07/20/2016 8:00:00 pm 11:20:00 pm 200 min No No
Yes BPIIWELBORD 4435
Determination Cause Depressure FS3/GC3 AL tie line to 500 psi due to PMP online
Action Taken Completed depressure to under 500psi and shut in
Total Volume (MSCF) 4927
Generated 08/02/2016 11:31:35AM
Page 2 of 4
Liz M
From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com>
Sent: Saturday, July 16, 2016 12:29 PM
To: AOGCC Reporting (DOA sponsored)
Cc Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, Martin, Nelson D; AK, HSSEE
Env Adv East, AK, OPS FS3 Facility OTL; Glover, Robin; Buckbee, Rachel A; AK, OPS FS3
OSM
Subject: Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aoacc reoortino(a)alaska oov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 07/07/2016 11:30 and stopping at 07/07/2016 13:00 with a volume of 96
(MSCF). The event lasted for 90 minutes and was due to depressurizing common line 6D for installation of temporary
pigging kit. The flaring event stopped when depressurization was complete.
A flaring event occurred at FS3 starting at 07/08/2016 07:45 and stopping at 07/08/2016 11:00 with a volume of 98
(MSCF). The event lasted for 195 minutes and was due to re -depressurizing common line 6D for installation of temporary
pigging kit after valves and leaked and repressurized from the day before. The flaring event stopped when
depressurization was complete and valves were confirmed to hold.
A flaring event occurred at FS3 starting at 07/08/2016 12:40 and stopping at 07/08/2016 15:00 with a volume of 17
(MSCF). The event lasted for 140 minutes and was due to depressurizing common line 6D after completing a pressure
build up test for the temporary pig kit installation. The flaring event stopped when depressurization was complete.
Thanks,
Jennifer Blake
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell(907)830-6204
Jennifer.blake(abo com
Liz M
From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com>
Sent: Saturday, July 30, 2016 8:57 AM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, Bessler, Mark; AK, HSSEE Env
Adv East; AK, OPS FS3 Facility OTL; Glover, Robin; Buckbee, Rachel A; AK, OPS FS3 OSM;
Fortenberry, Christopher
Subject: Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aoocc renortinc(a)alaska oov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 07/20/2016 20:00 and stopping at 07/20/2016 23:20 with a volume of 4435
(MSCF). The event lasted for 200 minutes and was due to depressurizing the FS3/GC3 Artificial Lift tie line to 500 psi for
maintenance work. The flaring event stopped when depressurization was complete.
Thanks,
Jennifer Blake
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell (907) 830-6204
Jennifer.blake@bp.com
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name
0290000030 PBU FS 33. Fie.. 4. Operator
._ PBU - EOA -- 5.
6. Sold
T Reinjected
8. Flared or vented 1 hour or less
9. Flared or vented more than 1 hour (see insh.)
10. Pilot and Purge
11. Assist Gas
12. Fuel gas used in lease operations.
13. Other (see instructions)
14. TOTAL VOLUME (ITEMS 6-12)
15. NGL Gas Equivalent
16. Purchased gas
17. Transferred from: CGF
18. Transferred to: (Express as a negative #) CGF
19. Remarks:
certify
Printed
the best of my
from
243
35,
EWE
941
Total Volume.
Lease Use
Conservation
917, 92
17,068,901
3ust-2016
poo/ as a gement
6555 �
6 -/.
I
Title Mana er Production Taxes and Ro alties Alaska Note: All volumes must be corrected
to pressure of 14.65 psia and to a
Phone (907) 564-5775 Date /0 /(O temperature of 60o F. Authority 20
Form 10-422 Rev. 5/2009
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
RP EXPLORATION (ALASKA) INC.
PRUDHOE RAY UNIT- FS -3
GAS FLARING INCIDENT REPORT
August 2016
events less than or equal to -1hour
TIME VOLUME DESCRIPTION OF INCIDENTS, CAUSE
Not required for unplanned events <= 1 hr
TOTAL 0
events greater than 1 hour
See attachments
TOTAL
0
Planned events less than or equal to 1 hour
DATE TIME
8/24/2016
VOLUME DESCRIPTION OF INI
1200-1210
3 See attachments
8/26/2016 0015-0030
240
TOTAL
243
Planned events greater than
1 hour
DATE TIME
8/18/2016
VOLUME DESCRIPTION OF INC
0400-1900
5,728 See attachments
8/24/2016 1200-1800
1,317
8/26/2016 0340-1200
1,514
TOTAL
8,559
Unplanned Events < 1 Hour
TOTAL0
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
exceeding 5,000 MCF
243
Planned Events> 1 hour or
exceeding 5,000 MCF
8,559
Pilot Purge
35,906
Assist
14,586
TOTAL FLARED VOLUME
59,294
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 5
9/12/2016
9:44 AM
Liz M
From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com>
Sent: Monday, August 29, 2016 11:43 AM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Bessler, Mark; AK, HSSEE Env
Adv East; AK, OPS FS3 Facility OTL; Glover, Robin; Buckbee, Rachel A; AK, OPS FS3 OSM;
Fortenberry, Christopher
Subject: Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aogcc reoorting(@alaskagov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 08/18/2016 04:00 and stopping at 08/18/2016 19:00 with a volume of 5728
(MSCF). The event lasted for 900 minutes and was due to STV/IP T/C 1802 shutdown due to a problem associated with
the filter housing. The flaring event stopped when the repair was completed and the compressor brought back online.
A flaring event occurred at FS3 starting at 08/24/2016 12:00 and stopping at 08/24/2016 18:00 with a volume of 1317
(MSCF). The event lasted for 360 minutes and was due to shutting down STV/IP T/C 1802 to repair a lube oil leak. The
flaring event stopped when the repair was completed and the compressor brought back online.
A flaring event occurred at FS3 starting at 08/26/2016 03:40 and stopping at 08/26/2016 12:00 with a volume of 1514
(MSCF). The event lasted for 500 minutes and was due to FS3 helping depressurize the EOA Artificial Lift (A/L) system
for planned maintenance repairs. The flaring event stopped when the depressurization was completed.
Thanks,
Jennifer Blake
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell (907) 830-6204
Jennifer. blakena bo com
Flare Start Date 08/01/2016
Flare End Date 08/31/2016
FS3 Flare Report
Report
Total Volume (MSCF) 8802
Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
is -255 Flare Relief o8/te/2016 4:00:00 am 7:00:00 pm s0o min No
Na Yes BP1{BOUWKA 5728
Determination Cause STV -IP T1C 1802 shutdown due to a problem associated with Filter housing
Action Taken Completed work & Brought back on line
Daily Volume (MSCF)
16-267 Controlled Blowdown 08/24/2016 12:00:00 pm 6:00:00 pm 360 min No
No Yes BP100NATR
Determination Cause 1802 SD for GG LO Leak repairs. Flared STV and IP Gas while turbine was repaired.
Action Taken _ Restarted the turbine once repairs were completed.
16-257 Contra led Blowdown 08/24/2016 12:00:00 pm 12:10:00 pm 10 min No
No Yes BP1\DONATR
Determination Cause Normal SD of 1802 T/C for GG LO repair.
Action Taken Completed the SD sequence.
16-272 Controlled Blowdown 08/26/2016 12:15:00 am 12:30:00 am 15 min No
Determination Cause Normal Shutdown of 1806 for FS1/2 AL Tieline anchor bypass job.
Action Taken Completed the blowdown sequence of 1806.
16-272 Controlled Blowdown 08/26/2016 3:40:00 am 12:0000 pm 500 min No
Determination Cause FSI/2ALTielinedepmwumdforanchorbypassjob.
Action Taken Completed the depressurization of the tieline.
Generated 09/01/2016 3:47:14PM
Daily Volume (MSCF)
No Yes BP1\DONATR
No _— Yes BPI\DONATR
Daily Volume (MSCF)
Total Volume (MSCF)
5728
1317
3
1320
240
1514
1754
8802
Page 6 of 9
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. FacilityNumber 2. Facility Name
0290000030 PBU FS 33. Field 4. Operator
PBU-EOA Ino 5.
6. Sold
7. Reinjected
8. Flared or vented 1 hour or less
9. Flared or vented more than 1 hour (see mstr.)
10. Pilot and Purge
11. Assist Gas
12. Fuel gas used in lease operations.
13. Other (see instructions)
14. TOTAL VOLUME (ITEMS 6-12)
15. NGL Gas Equivalent
16. Purchased gas
17. Transferred from: CGF
18. Transferred to: (Express as a negative #) CGF
19. Remarks:
true
Printed
Form 10-422 Rev. 5/2009
my
4,1
27,5
81, 572
765, 715
91
800,
-17,365.
Date
INSTRUCTIONS ON REVERSE SIDE
Pools, list conte
Total Volume.
Official Use
>1 hr:
Safety
Lease Use
Conservation
er-2016
as a perci
cote: All volumes must be corrected
to pressure of 14.65 Asia and to a
temperature of 600 F. Authority 20
Submit in Duplicate
iannea events less than or equal to 1 hour
DATE
9/3/2016
BP EXPLORATION (ALASKA) INC.
VOLUME DESCRIPTION OF IN
PRUDHOE BAY UNIT- FS -3
1900-1910
GAS FLARING INCIDENT REPORT
September 2016
planned events less than or equal to 1 hour
9/15/2016
DATE TIME VOLUME
9/9/2016
DESCRIPTION OF INCIDENT & CAUSE
0835-0845
9/30/2016
3 Not required for unplanned events <= 1 hr
1535-1540
24
TOTAL
27
Manned events greater than 1 hour
2135-2140
GATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
2300-2359
See attachments
TOTAL
0
iannea events less than or equal to 1 hour
DATE
9/3/2016
TIME
VOLUME DESCRIPTION OF IN
9/15/2016
1900-1910
240 See attachments
0030-0035
240
9/15/2016
0300-0305
3
9/20/2016
1110-1115
240
9/20/2016
1630-1635
240
9/24/2016
2135-2140
64
9/24/2016
2300-2359
467
9/26/2016
1530-1619
170
9/26/2016
1619-1645
206
9/26/2016
1645-1650
24
9/26/2016
2137-2145
1,535
9/26/2016
2330-2335
24
9/30/2016
0745-0845
229
9/30/2016
0845-0920
313
9/30/2016
0920-0925
24
9/30/2016
1250-1255
64
9/30/2016
1445-1450
24
TOTAL
4,107
Not required for unplanned events <= 1 hr
See attachments
See attachments
Page 5
10/14/2016
1.31 PM
9/3/2016
9/4/2016
9/15/2016
9/15-19/16
9/20/2016
9/25/2016
9/25/2016
9/25/2016
9/25/2016
2030-2359
2230-2359
0050-0250
0300-1230
1000-1115
0001-0140
0831-1300
0831-1300
0831-1300
TOTAL
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - FS -3
GAS FLARING INCIDENT REPORT
September 2016
2,552 See attachments
166
833
22,429
500
784
49
49
184
27,546
TOTAL
27
0
4,107
27,546
34,867
81,572
148,119
See attachments
Page 6
10/14/2016
1:31 PM
FlareStartDate o9/ol/2o16
Flare End Date 09/30/2016
FS3 Flare Report
Report
Total Volume (MSCF) 3168[
Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
16-284 Controlled Blowdown 09/03/2016 7:00:00 pm 7:10:00 pm 10 min No
No Yes BPIIDONATR 240
Determination Cause Normal Shutdown of 1806 TC for FS7/2 AL isolation. Normal Compressor piping blowdown.
Action Taken Completed the blowdown sequence of 1806.
16-284 Controlled Slowdown 09/03/2016 8:30:00 On 11:59:00 pm 209 min No
No Yes BPIIDONATR 2552
Determination Cause Depressured the AL pipeline from DS6/13/14 to FS3 for the FSI/2 AL Anchor bypass job reinstatement.
Action Taken Completed the depressurization of the pipeline for isolation.
Daily Volume (MSCF) 2792
16-287 Controlled Slowdown 09/04/2016 10:30:00 pm 11:59:00 pm 89 min No
No Yes BP1\DONATR 168
Determination Cause DS14 AL pipeline depressured due to pressure buildup on isolation of FS1/2 AL isolation
Action Taken Completed the depressurization of DS14 AL pipeline.
Daily Volume (MSCF) 166
16-302 Controlled Blowdown 09/15/2016 12:30:00 am 12:35:00 am 5 min No
No Yes BPIIWELBORD 240
Determination Cause TIC 1806 shutdown forplanned maintenance
Action Taken Completed shutdown.
16-302 Controlled Slowdown 09/15/2016 12:50:00 am 2:50:00 am 120 min No
No Yes
Determination Cause TIC 1806 spin cooling
Action Taken Completed spin cooling.
16-302 Commlled Slowdown 09/15/2016 3:00:00 am 3:05:00 am 5 min No
No Yes
Determination Cause Normal stop on 1802 for GG bore scope
Action Taken Completed shutdown.
16-302 Controlled Slowdown 09/15/2016 3:00:00 am 12:00:00 am 1260 min No
No yes
Determination Cause Flaring all STV and IP gas due to 1802 being shuttlown and no spare compressor.
Action Taken Still Oaring till 1802 can be repaired.
BP1\WELBORD 833
BPMELBORD 3
BPIIWELBORD 4473
Daily Volume (MSCF) 5549
16-307 Controlled Blowdown 09/16/2016 12:00:00 am 12:00:00 am 1440 min No
No Yes BPIIWELBORD 5100
Determination Cause Flaring STV and IP gas due to 1802 being out of service.
Action Taken Still Baring
16-313 Controlled Slowdown 09/17/2016 12:00:00 am 12:00:00 am 1440 min No
No
Determination Cause Flaring STV and IP gas due to 1802 being unavailable
Action Taken Still flaring
16-314 Controlled Blowdown 09/1&2016 12:00:00 am 12:00:00 am 1440 min No
No
Determination Cause Flaring STV and IP gas due to 1802 being unavailable
Action Taken Still flaring
Generated 10/04/2016 2:32:30PM
Daily Volume (MSCF) 5100
Yes B!"IMELSORD 5100
Daily Volume (MSCF) 5100
Yes SPIIWELBORD 5100
Daily Volume (MSCF) 5100
Page 5 of 10
Flare StartDate 09/01/2016
2656
Flare End Date 09/39/2016
2656
16-315 Controlled Slowdown 09/19/2016 12:00:00 am 12:30:00 pm 750 min
No
Determination Cause Flaring STV & IP gas due to 1802 being unavailable
No Yes BPIIDESCCR 206
Action Taken Completed STV/IP work
240
16-319 Controlled Slowdown 09/20/2016 10:00:00 am 11:15:00 am 75 min
No
Determination Cause Spinning 1806 AL T/C for water wash
Yes BPIIDESCCR
Action Taken Completed water wash
Action Taken Completed depressudng.
16-319 Controlled Blowdown 09/20/2016 11:10:00 am 11:15:00 am 5 min
No
Determination Cause 1806 AL TIC shutdown after water wash
Action Taken Completed shut down
269 min No
16-319 Controlled Slowdown 09/20/2016 4:30:00 pm 4:35:00 pm 5 min
No
Determination Cause 1806 AL T/C shutdown for CASTS test
Action Taken Completed depressudng.
Action Taken Completed shut down
16-332 Controlled Slowdown 09/24/2016 9:35:00 pm 9:40:00 pm 5 min
No
Determination Cause T\C 1803 shutdown for water wash and oasis testing with ESD
Action Taken Completed shutdown.
16-332 Controlled Blowdown 09/24/2016 11:00:00 pm 11:59:00 pm 59 min
No
Determination Cause T\C 1803 spin cooling forwaterwash
No
Action Taken Completed spin cooling.
184
No Yes BP7\BOUWKA
2656
Daily Volume (MSCF)
2656
No Yes BP1\WELBORD
500
16-330 Controlled Slowdown 09/26/2016 4:19:00 pm 4:45:00 pm 26 min No
No Yes BPIIDESCCR 206
No Yes BPIIWELBORD
240
No Yes BPI\WELSORD 240
Daily Volume (MSCF) 980
No Yes BP1\DESCCR 64
No Yes BP1\DESCCR 467
16-331 Controlled Blowdown 09/25/2016 12:01:00 am 1:40:00 am
Determination Cause T\C 1803 spin cooling for water wash
99 min No
No
Daily Volume (MSCF)
Yes BP7\DESCCR
531
784
Action Taken Completed spin cooling.
16-330 Controlled Slowdown 09/26/2016 4:19:00 pm 4:45:00 pm 26 min No
No Yes BPIIDESCCR 206
Determination Cause T1C 1803 spin cooling after water wash
16-331 Controlled Blowdown 09/25/2016 8:31:00 am 1:00:00 pm
Determination Cause Depressure 78 commonline for DS7 SD
269 min No
No
Yes BPIIDESCCR
49
Action Taken Completed depressudng.
Action Taken Completed shutdown.
Generated 10/04/2016 2:32:30PM
16-331 Controlled Blowdown 09/25/2016 8:31:00 am 1:00:00 pm
Determination Cause Depressure7Dcommonlinefor DS7SD
269 min No
No
Yes BP7\DESCCR
49
Action Taken Completed depressudng.
16-331 Controlled Slowdown 09/25/2016 8:31:00 am 1:00:00 pm
269 min No
No
Yes BP1\DESCCR
184
Determination Cause Depressure 7C commonline for DS7 SD
Action Taken Completed depressunng.
16-330 Controlled Slowdown 09/26/2016 3:30:00 pm 4:19:00 pm 49 min No
Daily Volume (MSCF) 1066
No Yes BPIIDESCCR 170
Determination Cause T\C 1803waterwash
Action Taken Completed water wash
16-330 Controlled Slowdown 09/26/2016 4:19:00 pm 4:45:00 pm 26 min No
No Yes BPIIDESCCR 206
Determination Cause T1C 1803 spin cooling after water wash
Action Taken Completed spin cooling.
16-330 Controlled Blowdown 09/26/2016 4:45:00 pm 4:50:00 pm 5 min No
No Yes BP7\DESCCR 24
Determination Cause T1C 1803 shutdown after water wash
Action Taken Completed shutdown.
Generated 10/04/2016 2:32:30PM
Page 6 of 10
Flare Start Date 09/01/2016
Yes
Flare End Date 09/30/2016
313
16-330 Controlled Blowdown 09/26/2016 9:37:00 pm 9.45:00 pm 8 min
No
Determination Cause Equalize AL pressures with GC3 for valve lineup after VS leak at GC1.
Action Taken Completed depressudng
24
16-330 Controlled Slowdown 09/26/2016 11:30:00 pm 11:35:00 pm 5 min
No
Determination Cause TC 1804 SD for water wash
Action Taken Completed shutdown.
16-336 Controlled Blowdown 09/30/2016 7:45:00 am 8:45:00 am 60 min
Determination Cause TC 1804 Waterwash
No
Action Taken Canpletedwaterwash
16-336 Controlled Blowdown 09/30/2016 8:45:00 am 920:00 am 35 min
No
Determination Cause TC 1804 spin cooling after water wash
Action Taken Completed spin cooling.
16-336 Controlled Blowdown 09/30/2016 9:20:00 am 9:25:00 am 5 min
No
Determination Cause TC 1804 shutdown after water wash
Action Taken Completed shutdown.
16-336 Controlled Slowdown 09/30/2016 12:50:00 pm 12:55:00 pm 5 min
No
Determination Cause TC 1804 shutdown for CASIS testing
Action Taken Completed shutdown.
16-336 Controlled Blowdown 09/30/2016 2:45:00 pm 2:50:00 pm 5 min
No
Determination Cause TC 1804 shutdown for planned maintenance
Action Taken Completed shutdown,
Generated 10/04/2016 2:32:30PM
No Yes BP10ESCCR 1535
No __-Yes BP1MESCCR 24
Daily Volume (MSCF) 1959
No Yes BPI\DESCCR 229
No
Yes
BPI\DESCCR
313
No---
Yes—�_—�BP1\DESCCR
24
No—
Yes BP1\DESCCR 64
No Yes BP10ESCCR 24
Total Volume (MSCF) 31680
Page 7 of 10
Liz M
From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com>
Sent: Wednesday, September 28, 2016 10:46 AM
To: AOGCC Reporting (DOA sponsored)
Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory,Bessler, Mark; AK, HSSEE Env
Adv East; AK, OPS FS3 Facility OTL, Glover, Robin; Buckbee, Rachel A; AK, OPS FS3 OSM;
Fortenberry, Christopher; Schinagl, Werner
Subject: Flaring Events at FS3
Follow Up Flag: Follow up
Flag Status: Flagged
To: AOGCC Reporting CC:
aogcc reoorting(.Walaska goy
Victoria Loepp, AOGCC
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 09/25/2016 00:01 and stopping at 09/25/2016 01:40 with a volume of 784
(MSCF). The event lasted for 99 minutes and was due to spin cooling of Turbine Compressor 1803 for water wash. The
flaring event stopped when spin cooling was completed.
A flaring event occurred at FS3 starting at 09/25/2016 08:31 and stopping at 09/25/2016 13:00 with a total volume of 282
(MSCF). The event lasted for 269 minutes and was due to depressurization of 7B, 7C, and 7D commonlines for DS7
shutdown. The flaring event stopped when depressurization was completed.
Thank you,
Jennifer Blake
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell (907) 830-6204
Jennifer.blake@bp.com
Liz M
From:
Sent:
AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com>
Thursday, September 22, 2016 10:11 AM
To:
AOGCC Reporting (DOA sponsored)
Cc:
Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Bessler, Mark; AK, HSSEE Env
Adv East; AK, OPS FS3 Facility OTL, Glover, Robin; Buckbee, Rachel A; AK, OPS FS3 OSM;
Subject:
Fortenberry, Christopher, Schinagl, Werner
Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
ao.qcc reoorting(alaskagov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 09/15/2016 00:50 and stopping at 09/15/2016 02:50 with a volume of 833
(MSCF). The event lasted for 120 minutes and was due to spin cooling Turbine Compressor 1806 for planned
maintenance. The flaring event stopped when spin cooling was completed.
A flaring event occurred at FS3 starting at 09/15/2016 03:00 and stopping at 09/16/2016 with a volume of 4473 (MSCF).
The event lasted for 1260 minutes and was due to STV/IP Compressor 1802 shutdown for planned maintenance. The
event continued into 9/16 as the compressor maintenance continued.
A flaring event occurred at FS3 starting at 09/16/2016 00:00 and stopping at 09/17/2016 with a volume of 5100 (MSCF).
The event lasted for 1440 minutes and was due to STV/IP Compressor 1802 shutdown for planned maintenance. The
event continued into 9/17 as the compressor maintenance continued.
A flaring event occurred at FS3 starting at 09/17/2016 00:00 and stopping at 09/18/2016 with a volume of 5100 (MSCF).
The event lasted for 1440 minutes and was due to STV/IP Compressor 1802 shutdown for planned maintenance. The
event continued into 9/18 as the compressor maintenance continued.
A flaring event occurred at FS3 starting at 09/18/2016 00:00 and stopping at 09/19/2016 with a volume of 5100 (MSCF).
The event lasted for 1440 minutes and was due to STV/IP Compressor 1802 shutdown for planned maintenance. The
event continued into 9/19 as the compressor maintenance continued.
A flaring event occurred at FS3 starting at 09/19/2016 00:00 and stopping at 09/19/2016 12:30 with a volume of 2656
(MSCF). The event lasted for 750 minutes and was due to STV/IP Compressor 1802 shutdown for planned maintenance.
The event stopped with the maintenance work was completed and the compressor restarted.
A flaring event occurred at FS3 starting at 09/20/2016 10:00 and stopping at 09/20/2016 11:15 with a volume of 500
(MSCF). The event lasted for 75 minutes and was due to spinning 1806 turbine compressor for water wash. The event
stopped when the water wash was completed.
Thanks,
Jennifer Blake
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell (907) 830-6204
Jennifer.blaket@bp.com
Link, Liz M
From:
Sent:
AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com>
To:
Tuesday, September 13, 2016 9:55 AM
AOGCC Reporting (DOA sponsored)
Cr
Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, Bessler, Mark; AK, HSSEE Env
Adv East; AK, OPS FS3 Facility OTL; Glover, Robin; Buckbee, Rachel A; AK, OPS FS3 OSM;
Fortenberry, Christopher, Schinagl, Werner
Subject:
Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aogcc reoorting(a)alaskagov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 09/03/2016 20:30 and stopping at 09/03/2016 23:59 with a volume of 2552
(MSCF). The event lasted for 209 minutes and was due to depressurization of the Artificial Lift (AL) pipeline from
DS6/13/14 to FS3 for the re -instatement of the AL system after the FS1/2 AL Pipeline Anchor remediation project. The
flaring event stopped when depressurization of the pipeline was completed for isolation.
A flaring event occurred at FS3 starting at 09/04/2016 22:30 and stopping at 09/04/2016 23:59 with a volume of 166
(MSCF). The event lasted for 89 minutes and was due to DS14 AL requiring re -depressurization due to pressure buildup
on the FS1/2 AL isolation. The flaring event stopped when depressurization was completed.
Thanks,
Jennifer Blake
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell(907)830-6204
Jennifer.blake2bo com
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY R9=Pn0T nr nil
Form 10-422 Rev. 5/2009
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - FS -3
GAS FLARING INCIDENT REPORT
October 2016
Not required for unplanned events <= 1 hr
TOTAL 0
events greater than
See attachments
TOTAL
0
Inned events less than or equal to 1 hour
DATE TIME VOLUME
10/10/2016
DESCRIPTION Of IN(
1100-1145
508 See attachments
TOTAL
508
Hoed events greater than 1 hour
508
DATE TIME VOLUME
DESCRIPTION OF INC
exceeding 5,000 MCF
See attachments
TOTAL
0
Unplanned Events < 1 Hour
TOTAL0
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
exceeding 5,000 MCF
508
Planned Events> 1 hour or
exceeding 5,000 MCF
0
Pilot Purge
35,740
Assist
5
TOTAL FLARED VOLUME
36,253
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 7
11/16/2016
5:13 PM
Flare Start Date 10/01/2016
Flare End Date 10/31/2016
Report FS3 Flare Report
Total Volume (MSCF) 508
Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
16-352 Controlled Blowdown 10/10/2016 11:00:00 am 11:45:00 am 45 min No
No Yes BMWELBORD 508
Determination Cause Commoned up 15B and 15D common lines and de -pressured lines to flare for 0815 shutdown
Action Taken Completed de -pressuring and shut in
Daily Volume (MSCF) 508
Total Volume (MSCF) 508
Generated 11/02/2016 4:05:39PM
Page 8 of 12
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY RFPnRT nG DDnnl lf%or%
Form 10-422 Rev. 512009
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT- FS -3
GAS FLARING INCIDENT REPORT
November 2016
events less than or equal to
Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr
TOTAL 0
events greater than 1 hour
See attachments
TOTAL 0
anned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF IN(
11/18/2016 1313-1331 463 See attachments
11/23/2016 0745-0840 283
11/23/2016 0745-0800 1
TOTAL 747
See attachments
TOTAL 0
Al IIUN TAKEN TO I
See attachments
See attachments
See attachments
Page 6
12/15/2016
12:31 PM
TOTAL
Unplanned Events < 1 Hour
0
Unplanned Events> 1 Hour
0
Planned Events < 1 hour and not
747
exceeding 5,000 MCF
Planned Events > 1 hour or
0
exceeding 5,000 MCF
Pilot Purge
34,630
Assist
584
TOTAL FLARED VOLUME
35,961
Al IIUN TAKEN TO I
See attachments
See attachments
See attachments
Page 6
12/15/2016
12:31 PM
Flare Start Date 11/01/2016
Flare End Date 11/30/2016
Report FS3 Flare Report
Total Volume (MSCF) 74-1
Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
16-421 Controlled Blowdown 11/18/2016 1:13:00 pm 1:31:00 pm 18 min No
No Yes BPi\DONATR 463
Determination Cause DS14 AL line depressured below 1000psig for welded sleeve install due to CUI PMP,
Action Taken Completed the depressurization of 14AL line.
Daily Volume (MSCF)
16435 Controlled BI
Owdown 11/23/2016 7:45:00 am 8:00:00 am 15 min No No
Yes
Determination Cause Normal Shutdown of 1802 STV/IP compressors to repair stripped boll from Turbine that was leaking air.
Action Taken Completed the Shutdown sequence.
16-435 Controlled Blowdowe 11/23/2016 7:45:00 am 8:40:00 am 55 min No No
Yes
Determination Cause Flared from the COSD/IP Sue. Scrubber due to 1802 Turbine being repaired.
Action Taken Restarted 1802 after repairs were made to the turbine air leak from the stripped bolt.
463
BP1\DONATR 1
BP1\DONATR 283
Daily Volume (MSCF) 284
Total Volume (MSCF) 747
Generated 12/15/2016 2:11:57PM
Page 7 of 12
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REP()RT rnG aQnni irCr% fl A Cl r.���.,�.�.....
Form 10-422 Rev, 5/2009 INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - FS -3
GAS FLARING INCIDENT REPORT
December 2016
than or equal to -1hour
Not required for unplanned events <= 1 hr
TOTAL 0
events greater than
See attachments
TOTAL 0
anned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INC
12/15/2016 1135-1145 1 See attachments
12/17/2016 0228-0238 1
TOTAL 2
12/4/2016 1317-1525
--"^•' .�caa.nir i lum OF IN
12/12/2016 0951-1644
401 See attachments
12/15/2016 1136-1240
2,187
12/17-24/2016 1428-0830
284
41,442
TOTAL
44,314
Unplanned Events < 1 Hour
TOTAL
0
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
exceeding 5,000 MCF
2
Planned Events > 1 hour or
exceeding 5,000 MCF
44,314
Pilot Purge
35,725
Assist
106,500
TOTAL FLARED VOLUME
186,541
Not required for unplanned events <= 1 hr
See attachments
See attachments
See attachments
Page 6
1/12/2017
2:11 PM
Link, Liz M
From:
Sent:
To:
Cc:
Subject:
AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com>
Wednesday, January 04, 2017 12:23 PM
AOGCC Reporting (DOA sponsored)
Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Bessler, Mark; AK, HSSEE Env
Adv East; AK, OPS FS3 Facility OTL, Glover, Robin; Buckbee, Rachel A; AK, OPS FS3 OSM;
Fortenberry, Christopher; Schinagl, Werner
Flaring Events at FS3
To: AOGCC Reporting CC: Victoria Loepp, AOGCC
aogcc reoorting(a)alaska gov
From: Jennifer Blake, GPB Production Optimization Team Leader
A flaring event occurred at FS3 starting at 12/04/2016 13:17 and stopping at 12/04/2016 15:25 with a volume of 401
(MSCF). The event lasted for 128 minutes and was due to depressurizing DS14's artificial lift system to install a sleeve on
a damaged section of line. The flaring event stopped when depressurization was completed.
A flaring event occurred at FS3 starting at 12/12/2016 09:51 and stopping at 12/12/2016 16:44 with a volume of 2187
(MSCF). The event lasted for 413 minutes and was due to idling STV/IP Compressor 1802 to make some cutovers for the
new STV/IP compressor and calibrate shutdown switches. The flaring event stopped when the cutover work was
completed and the compressor was reloaded.
A flaring event occurred at FS3 starting at 12/15/2016 11:36 and stopping at 12/15/2016 12:40 with a volume of 284
(MSCF). The event lasted for 64 minutes and was due to shutting down STV/IP compressor 1802 to repair a stripped bolt
from the turbine that was leaking air. The flaring event stopped when the work was completed and the compressor
reloaded.
A flaring event occurred at FS3 starting at 12/17/2016 14:28 and continuing into 12/18/2016 23:59 with a volume of 2577
(MSCF). The event lasted for 571 minutes and was due to startup testing of the new 1825 STV/IP compressor. The flaring
event continued into 12/18/2016.
A flaring event occurred at FS3 starting at 12/18/2016 00:00 and continuing into 12/19/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to startup testing of the new 1825 STV/IP compressor. The
flaring event continued into 12/19/2016.
A flaring event occurred at FS3 starting at 12/19/2016 00:00 and continuing into 12/20/2016 23:59 with a volume of 6500
(MSCF). The event lasted for 1439 minutes and was due to startup testing of the new 1825 STV/IP compressor. The
flaring event continued into 12/20/2016.
A flaring event occurred at FS3 starting at 12/20/2016 00:00 and continuing into 12/21/2016 23:59 with a volume of 6500
(MSCF). The event lasted for 1439 minutes and was due to startup testing of the new 1825 STV/IP compressor. The
flaring event continued into 12/21/2016.
A flaring event occurred at FS3 starting at 12/21/2016 00:00 and continuing into 12/22/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to startup testing of the new 1825 STV/IP compressor. The
flaring event continued into 12/22/2016.
A flaring event occurred at FS3 starting at 12/22/2016 00:00 and continuing into 12/23/2016 with a volume of 6500
(MSCF). The event lasted for 1440 minutes and was due to startup testing of the new 1825 STV/IP compressor. The
flaring event continued into 12/23/2016.
A flaring event occurred at FS3 starting at 12/23/2016 00:00 and continuing into 12/24/2016 with a volume of 4063
(MSCF). The event lasted for 1440 minutes and was due to startup testing of the new 1825 STV/IP compressor. The
flaring event continued into 12/24/2016.
A flaring event occurred at FS3 starting at 12/24/2016 00:00 and stopping at 12/24/2016 08:30 with a volume of 2302
(MSCF). The event lasted for 510 minutes and was due to startup testing of the new 1825 STV/IP compressor. The flaring
event stopped when startup testing was completed and 1825 was loaded and brought online.
Thank you,
Jennifer Bloke
EOC Production Optimization Team Lead
Office (907) 564-5926
Cell (907) 830-6204
Jennifer.blake@bp.com
Flare Start Date 12/01/2016
Flare End Date 12/31/2016
FS3 Flare Report
Report
Total Volume (MSCF)
44316
Numbs System Date Start Time Stop Time Duration Intermittent Bieck Smoke Planned Reported By
1 s-453 Controlled Blowdown 12104/2018 1:17:00 pm 3:25:00 pm 128 min No No Yes BPIIKLAWJJ
Determination Cause DS14 AL Depressured due to F -rank on line and line lift and sleeve location work
Action Taken Completed depressuring.
Volume
401
Daily Volume (MSCF)
16-458 Controlled Blowdown 12112/2016 9:51:00 am 4:44:00 pm 413 min No No Yes BPIIWELBORD
Determination Cause Idled 1802 T/C to make some cut overs for new compressor and calibrate shutdown switches.
Action Taken _ _ Completed cutover work and re -loaded compressor
401
2187
16-461 Controlletl Blowdown 12115/2016 11:35:00 am 1145:00 am 10 min No Daily Volume (MSCF)
No Yes BPIIDESCCR
Determination Cause Normal shutdown of 1802 STV/IP compressor to repair stripped bolt from turbine that was leaking air
Action Taken Completed Shutdown,
218
I
16-461 Controlletl Blowdown 12/15/2016 11:36:00 am 12:40:00 pm 64 min No --�--------
No
Determination Cause Flared from COSD/IP Suction Scrubber due to 1602 turbine being repaid
Action Taken Restarted 1802 after repairs were made to the turbine air leak from the stripped bolt
_---
Yes BPIIDESCCR
284
16-463 Controlled Blowdown 12/17/2016 2:28:00 pm 11:59:00 pm 571 min No No
Determination Cause Flared from COSD/IP Suction Scrubber for new 1825 compressor startup testing
Action Taken_ 1825 Startup testing in progress
Daily Volume (MSCF)
Yes BPIIDESCCR
285
2577
16463 Controlled Blowdown 12/17/2018 2:28:00 pm 2:38:00 pm 10 min No No
Normal Shutdown of 1802 STYes BPIIDESCCR
Determination Cause STWIP compressor for 1825 startup. Hopefully the last time this ever happens...
Action Taken Completed shutdown
1
16-465Daily
Controlled Blowdown 12118/2018 12:00:00 am 12:00:00 am 1440 min No No
Determination Cause Flared from COSD/IP Suction Scrubber for new 1825 compressor startup testing
Action Taken 1825 Startup testing in progress
Volume (MSCF)
Yes BPIIDESCCR
2578
6500
16-489 Controlled Slowdown 12/19/2018 12:00:00 am 11:59:00 pm 1439 min No No
Determination Cause 1802 STWIP Compressor shutdown for 1825 Compressor tasting. Flared from the COSD
Action Taken _ _ Continued testing the 1825 STV/IP Compressor.
Daily Volume (MSCF)
Yes BP7IDONATR
and IP Suction Scrubber.
6500
6500
Daily Volume (MSCF)
18470 Controlled Blowdown 12/20/2016 12:00:00 am 11:59:00 pm 1439 min No No Yes BPIIDESCCR
Determination Cause 1802 STWIP Compressor Shutdown for 1825 Compressor testing. Flared from the COSD and IP Suction Scrubber,
Action Taken _ Continuing testing of 1825 STWIP compressor
6500
6500
18471 Controlled Blowdown 12121/2016 12:00:00 am 12:00:00 am 1440 min No No
Determination Cause 1802 STV/IP Compressor Shutdown for 1825 STV/IP compressor testing.
Dally Volume (MSCF)
Yes BPIIDONATR
6500
6500
Action Taken Continued testing the 1825 compressor.
16-473 Daily Volume (MSCF)
Controlled Blowdown 12/22/2016 12:00:00 am 12:00:00 am 1440 min No No Yes BPIIDONATR
Determination Cause 1802 STVAP Compressor Shutdown for 1825 STWIP compressor testing. Flared from the COSD and IP Suction Scrubber
6500
6500
Generated 01/05/2017 1:53:26PM
Page 5 of 10
FlareStartDate 12/O V2016
Flare End Date 12/31/2016
Action Taken Continued test of 1825.
16-474 Controlled Blowdown 12/23/2016 12:00:00 am 12:00:00 am 1440 min No Daily Volume (MSCF) 6500
No Yes BP7IDONATR 4063
Determination Cause 1802 STWIP compressor shutdown for 1825 testing. We ran the 1825 compressorfor Ohre today. Flared from the COSD/IP Suc. Scrubber
Action Taken _ Continued testing on 1825 compressor.
16475 Controlled Blowdown 12/24/2016 12:00:00 am830:00 am 510 min No Daily Volume (MSCF) 4063
No Yes BP1\D0NATR 2302
Determination Cause Flared from COSD and IP Suction Scrubber while testing 1825 compressor.
Action Taken Completed the testing, and 1825 compressor is online.
Daily Volume (MSCF) 2302
Total Volume (MSCF) 44316
Generated 01/05/2017 1:53:26PM
Page 6 of 10