Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAbout213-1891. Type of Request: Abandon Plug Perforations Fracture Stimulate Repair Well Operations shutdown
Suspend Perforate Other Stimulate Pull Tubing Change Approved Program
Plug for Redrill Perforate New Pool Re-enter Susp Well Alter Casing Other: Convert to WAG
2.Operator Name: 4.Current Well Class:5.Permit to Drill Number:
Exploratory Development
3. Address:Stratigraphic Service
6. API Number:
7. If perforating:8. Well Name and Number:
What Regulation or Conservation Order governs well spacing in this pool?
Yes No
9. Property Designation (Lease Number): 10. Field:
11.
Total Depth MD (ft): Total Depth TVD (ft): Effective Depth MD: Effective Depth TVD: Junk (MD):
17,302'N/A
Casing Collapse
Conductor N/A
Surface 3,090psi
Production 5,410psi
Liner 8,100psi
Packers and SSSV Type: Packers and SSSV MD (ft) and TVD (ft):
12. Attachments: Proposal Summary Wellbore schematic 13. Well Class after proposed work:
Detailed Operations Program BOP Sketch Exploratory Stratigraphic Development Service
14. Estimated Date for 15. Well Status after proposed work:
Commencing Operations: OIL WINJ WDSPL Suspended
16. Verbal Approval: Date: GAS WAG GSTOR SPLUG
AOGCC Representative: GINJ Op Shutdown Abandoned
Contact Name:
Contact Email:
Contact Phone:
Authorized Title: Wells Manager
Conditions of approval: Notify AOGCC so that a representative may witness Sundry Number:
Plug Integrity BOP Test Mechanical Integrity Test Location Clearance
Other Conditions of Approval:
Post Initial Injection MIT Req'd? Yes No
APPROVED BY
Approved by: COMMISSIONER THE AOGCC Date:
Comm. Comm. Sr Pet Eng Sr Pet Geo Sr Res Eng
Baker Model S Hydro-Set Retainer Packer and N/A 14,760 MD/ 7,259 TVD and N/A
Ryan Lewis
ryan.lewis@hilcorp.com
303-906-5178
Perforation Depth MD (ft):
9.2 / L-80 / NSCT 14,798'
17,300'
See Schematic See Schematic 3-1/2"
80' 20"
9-5/8"
7"
7,310'
2-3/8"2,544'
14,947'
MD
N/A
7,700psi
5,750psi
7,240psi
4,482'
7,419'
7,495'
7,341'
14,976'
Length Size
Proposed Pools:
112' 112'
TVD Burst
MILNE POINT
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
APPLICATION FOR SUNDRY APPROVALS
20 AAC 25.280
ADL0025509, ADL0355017 & ADL0355018
213-189
3800 Centerpoint Dr, Suite 1400 Anchorage, AK 99503 50-029-22682-01-00
Hilcorp Alaska LLC
C.O. 816
AOGCC USE ONLY
Tubing Grade: Tubing MD (ft):Perforation Depth TVD (ft):
10/1/2024
Subsequent Form Required:
Suspension Expiration Date:
Will perfs require a spacing exception due to property boundaries?
Current Pools:
MPSP (psi): Plugs (MD):
17. I hereby certify that the foregoing is true and the procedure approved herein will not be deviated from without prior written approval.
Authorized Name and
Digital Signature with Date:
Tubing Size:
PRESENT WELL CONDITION SUMMARY
MILNE PT UNIT F-74A
KUPARUK RIVER OIL N/A
7,495' 17,300' 7,495' 2,471 N/A
No
Form 10-403 Revised 06/2023 Approved application valid for 12 months from date of approval.Submit PDF to aogcc.permitting@alaska.gov
By Grace Christianson at 8:09 am, Sep 30, 2024
Digitally signed by Taylor
Wellman (2143)
DN: cn=Taylor Wellman (2143)
Date: 2024.09.27 14:23:57 -
08'00'
Taylor Wellman
(2143)
324-562
SFD 10/2/2024
* Approved waiver to 20 AAC 25.265(f) - No gas injection check valve is required because no tubing
workover has been performed.
10-404
DSR-10/2/24MGR03OCT2024
* A well that was completed before December 3, 2010 that is subject to the requirements of (d) of this section and that is not
equipped with the functional hardware that would make a subsurface safety valve installation possible sooner,
must comply with the provisions of (d) of this section no later than the date that the well undergoes a tubing workover.
JLC 10/4/2024
Gregory Wilson Digitally signed by Gregory Wilson
Date: 2024.10.07 13:31:54 -08'00'
10/7/24
RBDMS JSB 100824
Well: MPF-74A
PTD: 312-189
API: 50-029-22682-01-00
Well Name:MP F-74A API Number:50-029-22682-01-00
Current Status:Injector Rig:LRS
Estimated Start Date:10/1/2024 Estimated Duration:1 days
Regulatory Contact:Tom Fouts Permit to Drill Number:213-189
First Call Engineer:Ryan Lewis (303) 906-5178 (M)
Second Call Engineer:Taylor Wellman (907) 777-8449 (O) (907) 947-9533 (M)
Current Bottom Hole Pressure: 3,191 psi @ 7,195’ TVD 12/14/2023 | 8.6 EMW, 8.8 KWF
Max Potential Surface Pressure: 2,471 psi Gas Column Gradient (0.1 psi/ft)
Max Angle:70°+ Sail Angle from 6,200’ MD
Brief Well Summary:
MPU F-74 was drilled in 1996 as a Kuparuk injection well. In 2014 was sidetracked to the East across a fault to
support the existing fault block and the adjacent fault block to support F-61 and F-65. We plan to convert this
well to a WAG injector.
Objectives:
Hilcorp is requesting a re-classification of this well to WAG Injector.
Notes Regarding Wellbore Condition:
Procedure (Non Sundried Work)
Fullbore
1. RU LRS, pressure test to 250psi low / 4,500psi high.
2. MIT- IA to 4,000 psi. Chart and record for 30 min.
3. RDMO.
7/16/24: Pre WAG MIT-IA 4000 psi, **Passed** 4.16 bbls diesel to pressure up, 15 min IA lost 38 psi, 30 min
IA lost 15 psi
Attachments:
Schematic
AOR Map
DATE REV. BY COMMENTS
Orig. RF elev. = 41.0' (N 22E)
Orig. GL. elev.= 11.80'
RT to tbg. spool = 28.60' (N 22E)
Tree:31/8"-5M
Wellhead:7 1/16" 5M FMC Gen. 5 Aw/
7 1/16" x 3.5"FMC Tbg. Hng. , 4.5
Acme Left Hand lift threads, 3 " CIW
"H" BPV profile
MILNE POINT UNIT
WELL F-74i
API NO: 50-029-22682
95/8",40#/ft,L-80 Btrc.
Perforation Summary
Size SPF Interval (TVD)
Hilcorp Alaska LLC
KOP @ 300'
Max. hole angle = 70° to 72°.
f/ 6,000' to 13,000'
Hole angle through perfs = 43°
20" 91.1 #/ft , H-40 csg.
MPU F-74A
112'
Stimulation Summary
01/29/97 - HPBD 6 stage, 3
gel three slick seawater, total
vol = 2344 bbls.
7" 26 3/ft , L-80, Btc Mod csg. ,
( drift ID = 6.151", cap. = 0.0383 bpf )
7" casing shoe
7" float collar (PBTD)
7,341'
RA Tag @ 14,743'
15,373'
15,292'
7/ 01/ 96 MDO Casing completion 22E
3.5" 9.3 ppf, L-80 NSCT tubing
ID = 2.992" DD = 2.876" = 0.0087 bpf
3.5" HES 'XN' npl.
(w/ 2.813" packing bore
w/ 2.80" no-go)
7" Baker 'SAB-3" Packer 14760'
Packer
Fluid
4 1/2 5 15000'-15012'
4 1/2 5 15020'-15044'
4 1/2 5 15050'-15114'
Perforated 32 G RDX Alpha-Jet 135/45Phasing (0.44", EHD = 32.1)
Ref Log: AWS SBT GR/CCL 7/8/96
14785'
(OLD)Completion PBTD = 15279' ELMD
7/21/96
Perforation Debris
7/22/96 DLH Initial Completion Polar Rig #1
350 bbl 10.1 ppg NaCl/NaBr
w/ 25gal/100bbl Cortex7726
60 bbl of Diesel
7439'-7447'
7453'-7471'
7476'-7523'
NOTE: Well requires the installation of
a SSSV during the next RWO.
42 deg. Milled window @ 14,976' ~14,981'
2-3/8 Deployment sleeve set
@, 14,757' (ID. 1.910")
26 jts 2-3/8 slotted liner 16,479 to 17,298
Lateral. 2~3/8" 4.7# L-80 Solid HYD 511 1.995"
16 jts 2-3/8 Solid liner 15,969 to 16,479
Completion PBTD =17,020 4/28/2014
38 jts 2-3/8 slotted liner 14,778 to 15,968
05/23/14 B.Kruskie Nordic 2 Coil Tub Drilling side track
Layed 17 ppg cement across
perfscement to target depth of 14748'MD
WhipStock set @14,976 4/28/14
Wells F-65, F-65L1, F-65L1-01, F-74, and F-74A appear to be adequately cemented. SFD
MEMORANDUM State of Alaska
Alaska Oil and Gas Conservation Commission
DATE:Tuesday, June 11, 2024
SUBJECT:Mechanical Integrity Tests
TO:
FROM:Sully Sullivan
P.I. Supervisor
Petroleum Inspector
NON-CONFIDENTIAL
Hilcorp Alaska, LLC
F-74A
MILNE PT UNIT F-74A
Jim Regg
InspectorSrc:
Reviewed By:
P.I. Suprv
Comm ________
JBR 06/11/2024
F-74A
50-029-22682-01-00
213-189-0
W
SPT
7259
2131890 1815
1779 1785 1780 1780
461 705 704 701
4YRTST P
Sully Sullivan
4/22/2024
Tested to 2500 for 500 psi DP
30 MinPretestInitial15 Min
Well Name
Type Test
Notes:
Interval P/F
Well
Permit Number:
Type Inj TVD
PTD Test psi
API Well Number Inspector Name:MILNE PT UNIT F-74A
Inspection Date:
Tubing
OA
Packer Depth
586 2532 2488 2479IA
45 Min 60 Min
Rel Insp Num:
Insp Num:mitSTS240423160309
BBL Pumped:2.6 BBL Returned:2.6
Tuesday, June 11, 2024 Page 1 of 1
CAUTION: This email originated from outside the State of Alaska mail system.
Do not click links or open attachments unless you recognize the sender and know
the content is safe.
From:Wallace, Chris D (OGC)
To:AOGCC Records (CED sponsored)
Subject:FW: NOT OPERABLE: MPF-74A (PTD# 2131890) Missed AOGCC Witnessed MIT-IA
Date:Wednesday, August 30, 2023 3:47:24 PM
From: Ryan Thompson <Ryan.Thompson@hilcorp.com>
Sent: Wednesday, August 30, 2023 2:36 PM
To: Wallace, Chris D (OGC) <chris.wallace@alaska.gov>; Regg, James B (OGC) <jim.regg@alaska.gov>
Cc: Taylor Wellman <twellman@hilcorp.com>
Subject: NOT OPERABLE: MPF-74A (PTD# 2131890) Missed AOGCC Witnessed MIT-IA
Mr. Wallace –
PWI well MPF-74A (PTD# 2131890) is currently shut in and will not be brought online for its
scheduled 4 year MIT-IA due this month. The well will now be classified as NOT OPERABLE and will
remain shut in. A witnessed MIT-IA will be scheduled once the well is returned to injection.
Please respond with any comments or concerns.
Thanks,
Ryan Thompson
Milne / Islands Well Integrity Engineer
907-564-5005
The information contained in this email message is confidential and may be legally privileged and is intended only for the use of theindividual or entity named above. If you are not an intended recipient or if you have received this message in error, you are herebynotified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, pleaseimmediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently deletethis message.
While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that the
onward transmission, opening, or use of this message and any attachments will not adversely affect its systems or data. No responsibility
is accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate.
MEMORANDUM
State of Alaska
Alaska Oil and Gas Conservation Commission
TO: Jim Regg 11��
P.I. Supervisor ' \"7 Z �`wl l (
DATE: Wednesday, August 28, 2019
SUBJECT: Mechanical Integrity Tests
11
Hilco p Alaska LLC
F -74A
FROM: Brian Bixby
MILNE PT UNIT F -74A
Petroleum Inspector
Src: Inspector
Reviewed B�.:'
P.I. SuprvJ
NON -CONFIDENTIAL
Comm
Well Name MILNE PT UNIT F -74A API Well Number 50-029-22682-01-00 Inspector Name: Brian Bixby
Insp Num: mitBDB190805065520 Permit Number: 213-189-0 Inspection Date: 8/1/2019
Rel Insp Num:
Packer Depth Pretest Initial IS Min 30 Min 45 Min 60 Min
Well F 74A - Type lnj I W -TVD 7259 - Tubing 1189 - _1289. ?a 1294
_I
PTD 2131890 - Type Test SPT (Test psi 1815 IA 416 2006 90 1953
BBL Pumped: 2 BBL Returned: 2 OA 241 445 - 443 - 444 -
Interval 4YRTST PIF 1, ✓
I Notes:
Wednesday, August 28, 2019 Page I of 1