STATE OF ALASKA
nin
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
103000001 7
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. Month/Year of Disposition
January -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
42,240
Pool Name Pool Code Percent
7. Reinjected
1,819,264
ALPINE 120100 56.9%
FIORD 120120 36.4%
8. Flared or vented 1 hour or less
2,019
NANUQ 120175 2.8%
NANUQ-KUPARUK 120100 3.0%
9. Flared or vented more than 1 hour (see instr.)
0
QANNIK 120180 0.9%
OTHER 120180 0.0%
10. Pilot and Purge
6,754
11, Assist Gas
00.0%
12. Fuel gas used in lease operations.
492,132
13. Other (see instructions)
Official Use Only
Authorization 11 hr
Safety
MCF
14. TOTAL VOLUME (ITEMS 6.73)
2,362.409
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Gas sold to Alpine Transportation Company = 27,922
Gas gifted to Village of Nuiqsut =14,318
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
AG(�
Signature: yY Li2G�l�C./P-2B Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60°F. Authority 20
AAC25.235.
Printed Name: Diane Hendrickson Phone: Date: February 20, 2017
Form 10-422 Rev. S/2009 INSTRUCrIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO.663
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Jan -17
Total Flare > 1 Hour 0
Total Flare <=1 Hour 2.019
Pilot aaU P.M. 6,754
Total Flare 8,773
STATE OF ALASKA
nin
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. Month/Vear of Disposition
February -17
Disposition
Volume MCF
20. Forproduction from multiple pools. list contribution of each pool as a percent of Total
Volume.
6. Sold
37,974
Pool Name Pool Code Percent
7. Reinjected
1.576,827
ALPINE 120100 56.87%
FIORD 120120 35.3%
8. Flared or vented 1 hour or less
1,663
NANUO 120175 3.0%
NANUO-KUPARUK 120100 3.6%
9. Flared or vented more than 1 hour (see instr.)
21,520
OANNIK 120180 1.4%
OTHER 120180 0.0%
10. Pilot and Purge
8,481
11. Assist Gas
00.0%
12. Fuel gas used in lease operations.
438,799
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
2 J 52-C
MCF
14. TOTAL VOLUME (ITEMS 6.13)
2,085,264
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
4-5-/
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Gas sold to Alpine Transportation Company = 24,388
Gas gifted to Village of Nuiqsut =13,586
1 hereby certify that the foregoing is true and correct to the best of my knov ledge.
nature: ��^Y%L^ Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60'F. Authority 20
AAC25.235.
rPrg,nted Name. Diane Hendrickson Phone: Date: March 20, 2017
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
✓TL
4/4117 -
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Feb47
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED MSCF DESCRIPTION OF FLARING EVENT
ACTION TAKEN TO MINIMIZE VOLUME
The TIC#33012-TB combustion system developed a leak requirvlg an
02/07/2017 13:37 02/08/2017 03:52 PLANNED 21261 emergency shutdown to inspect. Upon inspection, it was discovered The fuel gas noule assembly was repaired and reinstalled
the fuel gas noale had to be replaced.
The Low Pressure compressor tripped off line due to a faulty pressure Instrument technicians corrected the issue wfth me faulty
02/08/2017 2028 02/08/2017 21:41 PLANNED 259 transmitter while the facility was in late stages of a restart transmitter allowing the compressor to be returned to
service
2115e)
Toted Ram >1 Hour 21,520
Total Flare <=1 Hour 1863
Pilotam/Purge 8,481
Total Flare 31.664
Alpine Environmental
From: Alaska SCADA <AlaskaSCADA@cop.com>
Sent: Wednesday, February 08, 2017 3:55 AM
To: ALP SCADA Analyst; Alpine Lead Operators; NSK Env Coord Air Quality & Spill Plans;
Alpine Environmental; ALP Automation
Subject: # ALPINE SCADA: Reportable LP Flare Event
IP21 has recorded a reportable LP Flare event
Flare Event Number:
1634
Flare Event Started:
07 -FEB -17 13:47:00.0
Flare Event Ended:
08 -FEB -17 03:51:53.8
Flare Event Duration:
14 Hours, 4 Minutes, 53.8 Seconds
Flare Event Volume:
4501.09 (MSCF)
Go to IP21 Flare Event History display (FLAREHLP) for more details.
This email was generated by SQL: FLR_Event on 08 -FEB -17 03:54:28.2
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY: Alpine Central Facility AIR PERMIT NUMBER: AQ0489TVP02
GAS DISPOSITION
Date of Occurrence: 2/7/2017 dere ❑rent
Time of Occurrence:
00_0024100 HH,MM
(mm/dd/yy) (Check Selection)
From: 13:41 To: 00__00 = 10:13
Total Volume Flared or Vented: 4501 MSCF BELS
From: 00:00 To:. 52 = 03:52
Planned ❑+ Unplanned ❑
From: To:
From: To: -
Meter N0: 35012 (By Facility) Total Minutes Flared or Varied 845 minutes
(Includes
volume flared which generated black smoke. If applicable)
A. Description of Incident and Cause: (Check as many as needed to fully describe the Incident)
X S/D T/CH 33012 -TB for vee beim
Process upset In
TIC SD due to high exhaust temperature
section of facility
X EMERGENCY SHUTDOWN
Flaring for drillaile shutdown/startup
Electrical/ Instrumentation malfunction
Flare system testing
ExcessivalmauPieient inlet gas rates into nullity
Faulty shutdown on
SID on high vibration
Facility Maintenance
v
011ier:
Comments:
The T/Ca 33012 -Ta mmhuseon system tlevelopetl a ;a;:i en emsrgentysM1Ntlown W Paped. Upon inspallon, it was d'acovemtl the fuel0o noule hatl to De replaced.
B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
X Started 1 reatarted TIC # 33m2 -Ta
Stabilized facility process and operation
Com ressor/traindepressured
X Repaired equipment difficulties
X Redticetl t% increased Inlet gas rates
with fuel gas mules
Completed flare testing
Facility maintenance completed
Corrected E81 fluctuation / failure
Other.
Comments:
The fuel gas nozzle assembly was repaired and reinstalled.
C. Flaring or Venting was: (Check one)
necessary for facility operations, repairs, upgrades, or testing procedures
❑ an emergency that threatened life or property
❑ necessary to Eftent loss of ultimate recovery
Venting Incident
❑ No: ❑
(If Yes, complete form & contact Environmental immediately)
Was the volume over 1,000 mecf? Yes:
Flare =dent
TRUE
Did Incident last for longer than 1 hour? Yes [7 No ❑
If Yea, fax this report to Environmental within 24 hours at KRU-669-7712 or ALP at 670.45D7
Did event cause any smoke' > 5 minutes in 2 hr or 20% opacity for 6 consecutive minutes? Yes:
E]No: 0
If Yea, contact Envimmental Immediately KRU 669-7242 or ALP 670-4200 and fax this report to Env
at KRU- 659-7712 or ALP at 670.4607
(enter tag number and description)
Black smoke' emitted from source:
Date and time of black smoke' event: From: T°
MSCF
Volume flared which generated black smoke':
_BELS
Description of steps to minimize emissions: (Section B above)
Material flared: Gas: NGLs:
Other:
General Weather: Air Temperature: Wind Speed/Dlmction:
' Observation by Non -Certified Visible Emission Observer
Based on Information and belief formed after reasonable Inquiry, I certify that the statements and Information In and attached to this
document are true, accurate and complete..--,[p''',J/
Q
Date �, I
Facility Supervisor L- V —moi
1
cc: Alpine: Field Environmental Compliance Coordinators, n1838 or ALP -14
Kupamk: Field Environmental Compliance Coordlnaers, n1037 or NSK- 61
020717 LP Fbro GF end VR repwUh
2/8.1017
Alpine Environmental ` � � )
From: Alaska SCADA <AlaskaSCADA@cop.com>
Sent: Wednesday, February 08, 2017 3:54 AM
To: ALP SCADA Analyst; Alpine Lead Operators; NSK Env Coord Air Quality & Spill Plans;
Alpine Environmental; ALP Automation
Subject: # ALPINE SCADA: Reportable HP Flare Event
IP21 has recorded a reportable HP Flare event
Flare Event Number: 87
Flare Event Started: 07 -FEB -17 13:47:00.0
Flare Event Ended: 08 -FEB -17 03:51:53.8
Flare Event Duration: 14 Hours, 4 Minutes, 53.8 Seconds
Flare Event Volume: 16760.4 (MSCF)
Go to IP21 Flare Event History display (FLAREHHP) for more details.
This email was generated by SQL: FLR_Event on 08 -FEB -17 03:54:17.1
GAS FLARING or VENTING REPORT -CONOCOPHILLIPS ALASKA, INC.
FACILITY: Alpine Central FaClIlty AIR PERMIT NUMBER: AQD489TVP02
GAS DISPOSITION
Data of occurrence: 2812017 owne ❑yam Time of Occurrence:
00_00 24:00 HH:MM
(m ucia W) (Check Selection)
From: 13:47 To: 00:00 10:13
Total Volume Flared or vented: 16760_MSCF BELS From: 00:00 To: 03_52 = 03:52
Planned ❑+ Unplanned ❑ From: To: ,_.
From: To:
Meter No: 35011 By Facility) Total Minutes Flared or Vented = B45minulas
(Includes volume flared which generated black smoke, 9 applicable)
A. Description of Incident and Cause: (Check as many as needed to fully describe the Incident)
X SIO TIC# 3301?TB for see bebv: Process upset in
TIC SD due to high exhaust temperature section of facility
X EMERGENCY SHUTDOWN Flaring for ddllsite shutdown/startup
Elect ical I Instvnentalion mallunction Flare system testing
Excessrvelinsufgclenl inlet gas rates into facility Faulty shutdown on
SID on high vibration
Facility Maintenance
Other:
Comments:
Tne TICa 33012 -TB camIOU sllon system devebped a leak rewiring an emergency aeuttlown to In%pest. Upgn Mcpedlan, itwas tliscoveree 1M1e (uN gas norzla M1ad to be rcplaud.
E. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
X Started / restarted T/C R 33o1] -Te Stabilized facility process and operation
Compressor/ train depressured X Repaired equipment difficulties
X EI---_ with fuel gas nozzles
R -Wu- Increased inlet gas rales
Facility maintenance completed
Completed flare testing
Corrected E&I fluctuation / failure Other:
Comments:
The Fuel gas nozzle assemhly was repaired and reinstalled.
C. Flaring or Venting was: (Check one)
❑ an emergency that threatened fife or property
❑+ necessary for facility opera lons, repairs, upgrade&, or testing procedures
❑ necessary to prevent lose of ultimate recove
VeatlnD Incldent
❑ No: ❑ (If yes, complete form & contact Environmental Immediately)
Was the volume over 1,000 m9cf7 Yes:
Flare Incident TRUE
Did Incident last for longer than 1 hour? Yes ❑+ No ❑
If Yes, fax this report to Environmental within 24 hours at KRU- 669.7712 or ALP at 670-4607
Did event cause any smoke' > 5 minutes In 2 hr or 20% opacity for 6 consecutive minutes? Yes: ❑ No: ❑+
If Yes, contact E vin me tal Immediately KRU 659.7242 or ALP 870-4200 and fax this report to Env at KRU- 659-7712 or ALP at 670-4607
(enter tag number and description)
Black smoke' emitted from source:
T°
Date and time of black smoke' event. From:
MSCF
_RBCS
Volume tiered which generated black smoke':
Descriptlon of steps to minimize emissions: (Section B above)
Materiel flared: Gas; NGLs: Other:
General Weather: Air Temperature: Wind Speed/Direction:
• Observation by Non -Certified Visible Emission Observer
Based on Information and belief formed after reasonable inquiry. I certify that the statements and Information In and attached to this
document are true, accurate and complete. �.- ,r� ,-a 9 ,..
� Date G.1 `111 LI
Facility Supervisor �!`'�SL�/
oc: Alpine: Field Environmental Compliance Coordinators, n1838 or ALP -14
Kupeauk: Field Environmental Compliance Coordinators, nl037 or NSK-61
W0717 HP Flare OF erel VR repen.xis
bw2m7
STATE OF ALASKA
nin
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1 03 000001 7
12. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. Month/Year of Disposition
Manch-17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
42,909
Pool Name Pool Coda Percent
7. Reinjected
1,888,992
ALPINE 120100 62.9%
FIORD 120120 29.8%
8. Flared or vented i hour or less
47
NANUO 120175 2.6%
NANUO-KUPARUK 120100 3.1%
9. Flared or vented more than i hour (see Instr.)
0
OANNIK 120180 1.6%OTHER
120180 0.0%
10. Pilot and Purge
7,102
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
498,806
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6.13)
2,437,856
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Gas sold to Alpine Transportation Company = 28,617
Gas gifted to Village of Nuiqsut =14,292
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature: v �'a� ��� Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psis and to a
temperature of 60°F. Authority 20
AAC25.235.
Printed Name: Diane Hendrickson Phone: Date: April 20, 2017
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Mar -9
DATE
START
TIME
END
DATE
TIME
PLANNED
UNPLANNED
VOLUME
MSCF
DESCRIPTION OF FLARING EVENT
ACTION TAKEN TO MINIMIZE VOLUME
Total Flare = t Hour 0
Trial Flare <= f Hovr 47
Pilot And Pw,. 7,102
Total Flare 7,148
STATE OF ALASKA
nin
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator 5. Month/Year of Disposition
CONOCOPHILLIPS ALASKA, INC. April -17
Disposition
Volume MCF
20. For production hom multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
41,667
Pool Name Pool Code Percent
7. Reinjected
17792,238
ALPINE 120100 69.9%
FIORD 120120 22.4%
8. Flared or vented 1 hour or less
683
NANUO 120175 2.83%
NANUO-KUPARUK 120100 3.1%
9. Flared or vented more than 1 hour (see instr.)
0
QANNIK 120180 1.8%
OTHER 120180 0.0%
10. Pilot and Purge
8,048
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
460,148
13. Other (see instructions)
Official Use Only
Authorization >i hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-13)
2,302,784
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Gas sold to Alpine Transportation Company = 29,060
Gas gifted to Village of Nuigsut =12,607
1 hereby certify that the foregoing is two and correct to the best of my knowledge.
��
Signature: Ni Title: Revenue 8 Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60°F. Authority 20
AAC25.235.
Printed Name: Diane Hendrickson Phone: Date: May 20, 2017
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Apr -1T
Total Flare > 1 Hour
Total Flare — I Hour 683
Pilot and Pmge 8 M
Total Flare 8731
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
103000001 7
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator 5. Monthlyear of Disposition
CONOCOPHILLIPS ALASKA, INC. May -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
volume.
& Sold
40,400
Pool Name Pool Code Percent
7. Reinjected
7892,688
ALPINE 120100 72.9%
FIORD 120120 18.8%
8. Flared or vented 1 hour or less
10,112
NANUQ 120175 2.8%
NANUQ-KUPARUK 120100 3.6%
9. Flared or vented more Than 1 hour (see instr.)
0
QANNIK 120180 1.9%OTHER
Undefined 0.0%
10. Pilot and Purge
11,911
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
453,414
13. Other (see instructions)
Official Use Only
Authorization >l hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 611 3)
2,408.525
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
Date
18. Transferred to: (Express as a negative #)
19. Remarks: Gas sold to Alpine Transportation Company = 31,130
Gas gifted to Village of Nuiqsut =9,270
1 hereby certify that the foregoing is true and correct to the best of my knov4edge.
Signature: Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60°F. Authority 20
AAC25.235.
Printed Name: Diane Hendrickson Phone: Date: June 20, 2017
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
May4T
DATE
START
TIME
DATE
END
TIME
PLANNED
UNPLANNED
VOLUME
MSCF
DESCRIPTION OF FLARING EVENT
ACTION TAKEN TO
MINIMIZE VOLUME
Total Fkre> 1 Hour 0
Total Flare_ 1 Hour 10.112
Pilotanrt PuMe 11.911
Total Flare 22,023
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. Month/Year of Disposition
June -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
31,329
Pool Name Pool Code Percent
7. Reinjected
1,570,998
ALPINE 120100 73.3%
FIORD 120120 15.1%
8. Flared or vented 1 hour or less
10,461
NANUQ 120175 2.5%
NANUQ-KUPARUK 120100 6.9%
9. Flared or vented more than 1 hour (see insU.)
3,180
QANNIK 120180 2.2%
OTHER Undefined 0.0%
10. Pilot and Purge
13'948
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
383,396
13. Other (see instructions)
Official Use Only
Authorization 11 hr:
Safety
-3 /86
MCF
14. TOTAL VOLUME (ITEMS 8.13)
2,013,312
Lease Use
MCF
15. NGL Gas Equivalent - -
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
Commissioner J Date
18. Transferred to: (Express as a negative #)
19. Remarks: Gas sold to Alpine Transportation Company = 25,585
Gas gifted to Village of Nuiqsut =5,744
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
��� Note: All volumes must be corrected to
nature: %L Title: Revenue & Regulatory Analyst pressure of 14.65 psia and to a
temperature of 60'F. Authority 20
rPr9,7nt,dme:Diane Hendrickson Phone: Date: July 20, 2017 AAC25.235.
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
V TL'
IoII}(l'*
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Jun -17
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCFI DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
Total Flare> 1 Hour 3,188
Total Flare <=1 Hour 10,461
PllPtand Purge 13,948
Total Flare 27,589
LP Compressor suction meter instrument malfunction causing LP
Board operators notified instrument tech and discussed
06/14/2017
19:01
06/14/2017 20:26
UNPLANNED 409
Compressor to trip
compressor trip.Instrument tech cleaned and repaired
malfunctioning instrument and restarted.
06/15/2017
16:46
06/15/2017 18:01
PLANNED 410
LP compressor shutdown while transitioning power generation system
Restarted LP compressor
for facility maintenance
06/15/2017
2323
06/16/2017 0047
PLANNED
LP compressor shutdown while harshening power generation system
Restarted LP compressor
for facility maintenance
06/18/2017
21:29
06/18/2017 2341
UNPLANNED 2244
Alpine Facility was shut down for annual maintenance. Gas was flared
Total facility restart
during startup while transition to normal Operations
06/19/2017
01:22
06/19/2017 02:50
UNPLANNED 117
Alpine Facility was shut down for annual maintenance. Gas was flared
Total facility restart
during startup while transition to normal Operations
Total Flare> 1 Hour 3,188
Total Flare <=1 Hour 10,461
PllPtand Purge 13,948
Total Flare 27,589
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY: Alpine AIR PERMIT NUMBER: A00489TVPOI
GAS DISPOSITION
Date of Occurrence: 6/14/2017 Bert Time of Occurrence:
H.,Min
(mm/dd/yy) (Check Selection) 00:00 24_00
From: 19:01 To: 20:26 = 01:25
Total Volume Flared or Vented: 409.2 MSCF BBLS From: To:
ka,
Planned ❑ Unplanned yu From: To: _ _
From: To: _ _
Meter No: MTR-35g12 Total Minutes Flared or Vented is0126
(Includes volume Flared which generated Mack smoke. if applicable)
A. Description of Incident and Cause: (Check as many as needed to fully describe the incident)
SID TIC# for X Process upset in C3 Module LP Compressor
TIC SO due Nmics at teoperalure section of facility
Iogh
EMERGENCY SHUTDOWN Flaring for drillsile shutdown / startup
Electrical / Instrumentation manunclion Flare system testing
ExcessivernsumcleM Inlet gas rates Into facility Fealty shutdown an —
SID on high temperature
Facility Maintenance X Other: C-33012 LP Compreasor-High Temp SO
Comments:
LP Compressor suction meter instrument malfunction causing LP Compressor trip
B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted TIC # Stabilized facility process and operation
Compressor/ train depressured Repaired equipment difficulties
Reduced / increased inlet gas rates with
Completed flare testing Facility maintenance completed
X Corrected E&I fluctuation / failure Other:
Comments:
Board operators whfiad insWmenl tech and discussed conpressor trip. Instrument tech cleaned and repair malfunlianing instrument and restarted.
C. Flaring or Venting was: (Check one)
I] necessary for facility operations, repairs, upgrades, or testing procedures ❑ an emergency that threatened life or property
❑ necessa to even) lose of ultimate remve
Ventina Incident
❑ No: ❑ (If Yes, complete form & contact Environmental immediately)
Was the volume over 1,000 mscf7 Yes:
Flare Incident TRUE
Did incident last for longer than 1 hour? Yea 2 No ❑
If Yes, fax this report to Environmental within 24 hours at KRU- 669-7712 or ALP at 6704607
Did event cause black smoke' > 3 minutes in 1 hr or 6 consecutive minutes? Yes: ❑ No:
If Yes, contact Enviromental'mmediat d KRU 669-7242 or ALP 6704200 and fax this report to Env at KRU- 669-7712 or ALP at 6704507
(enter tag number and description)
Black smoke' emitted from source:
Date and time of black smoke event: From: To:
Volume Oared which generated black smoke': MSCF _BBLS
Description of steps to minimise emissions: (Section B above)
Material flared: Gas: X NGLs: Other:
General Weather: Air Temperature: SOF ambient Wind Speed/Direction: NE tOMPH
' Observation by Non -Certified Visible Emission Observer
Based on Information and belief formed after reasonable Inquiry, I certify that the statements and information in and attached to this
document are true, accurate and complete
Date
��
Facility Supervisor
cc: Alpine: Field Environmental plvmce Coordinators, ALP -14
Ku awk: Field Environmental Compliance Coordinators, NSK-61
LP Gas Flad,q Raped 061417-revl.As
6115/2017
Alpine Environmental
From: Alaska SCADA <AlaskaSCADA@cop.com>
Sent: Wednesday, June 14, 2017 8:28 PM
To: ALP SCADA Analyst; Alpine Lead Operators; NSK Env Coord Air Quality & Spill Plans;
Alpine Environmental; ALP Automation
Subject: # ALPINE SCADA: Reportable LP Flare Event
IP21 has recorded a reportable LP Flare event.
Flare Event Number: 3794
Flare Event Started: 14 -JUN -1719:01:00.0
Flare Event Ended: 14 -JUN -17 20:25:49.1
Flare Event Duration: 1 Hour, 24 Minutes, 49.1 Seconds
Flare Event Volume: 409.186 (MSCF)
Go to IP21 Flare Event History display (FLAREHLP) for more details.
This email was generated by SQL: FLR_Event on 14 -JUN -17 20:28:02.4
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY: Alpine AIR PERMIT NUMBER: AQ0489TVP01
GAS DISPOSITION
Date of Occurrence:6/15/2017 +fibre ❑yam Time of Occurrence:
(mm/dd/yy) (Check Selection) 00_00 24:00 RnM'n
From: To: _
Total Volume Flared or Vented: 93 MSCF BELS From: 23:23 To: 00_47 = 01:24
Planned ❑ Unplanned 0 From: To: _
From: To: _
Meter No: MTR-35012 Total Minutes Flared or Vented 0124
(includes volume flared which generated black smoke, if applicable)
A. Description of Incident and Cause: (Check as many as nestled to fully describe the Incident)
SID T/Ck Process upset In
T/C SD due to high exhaust temperature section o1 facility
EMERGENCY SHUTDOWN Flaring for dr ilsge shutdown I startup
Electrical I Instrumentation malfunction Flare system testing
Excessivelinsulficienl inlet gee rales into facility Faulty shutdown on
X Facility Maintenance
X Other: SD of Alpine production Facility
Comments:
Alpine maintenance shutdown activities resulted in flared gas to complete the shutdown and depressurize the facility
S. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted TIC M Stabilized facility process and operation
Compressor / train depressured Repaired equipment difficulties
X Reduced / increased inlet gas rates with
Completed flare testing Facility maintenance completed
Connected E&I fluctuation/failure Other.
Commands:
ting norther flare emmisslons for the malnlnenace activity.
7777=
C. Flaring or
❑+ necessary for facility operations. repairs, upgrades, or testing procedures ❑ an emergency that threatened life or property
❑ necessmy to prevent less of ultimate mcove
Venting Incident
❑ No: ❑ (If Yes, complete form & contact Environmental Immediately)
Was the volume over 1,000 mscf? Yes:
Flare Incident TRUE
Did incident last for longer than 1 hour? Yes ❑+ No ❑
I/ Yes, fax this report to Environmental within 24 hours at KRU- 669-7712 or ALP at 6704607
Did event cause black smoke-> 3 minutes In 1 hr or 6 consecutive minutes? Yes: ❑ No: ❑+
If Yea, contact Env romental immediately KRU 669-7242 or ALP 670-4200 and fax this report to Env at KRU- 669-7712 or ALP at 670.4507
(enter lag number and description)
Black smoke' emitted from source:
Dale and time of black smoke event: From: To:
Volume flared which generated black smoke': MSCF _BBLS
Description of steps to minimize emissions: (Section B above) Si all Producing "Is for the maintenance activity
Material (tared: Gas: 93 msof NGLs: Other:
General Weather: Air Temperature: 29F ambient Wind Speed/Direction: 10MPH NE
' Observation by Nan -Certified Visible Emission Observer —
Based on information and belief formed after reasonable Inquiry, I certify that the statements and information In and attached to this
document are hue, accurate and complete
Data (.Q 1 I l.e 1 v'7
Facility Supervisor
cm Alpine: Field Environmental Compliance Coordinators, ALP -14
Ku aruk: Field Environmental Compliance Coordinators, NSK-fit
LP Gas Flaring Repel 081517-2.ds
WINZD17
Alpine Environmental
From: Alaska SCADA <AlaskaSCADA@cop.com>
Sent: Friday, June 16, 2017 12:50 AM
To: ALP SCADA Analyst; Alpine Lead Operators; NSK Env Coord Air Quality & Spill Plans;
Alpine Environmental; ALP Automation
Subject: # ALPINE SCADA: Reportable LP Flare Event
IP21 has recorded a reportable LP Flare event
Flare Event Number: 3798
Flare Event Started: 15 -JUN -17 23:22:00.0
Flare Event Ended: 16 -JUN -1700:46:33.8
Flare Event Duration: 1 Hour, 24 Minutes, 33.8 Seconds
Flare Event Volume: 93.3699 (MSCF)
Go to IP21 Flare Event History display (FLAREHLP) for more details.
This email was generated by SQL: FLR_Event on 16 -JUN -17 00:49:32.5
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY: Alpine AIR PERMIT NUMBER: AQ0489TVP01
GAS DISPOSITION
Date of Occurrence: 6115/2017+�bm ❑- Time of Occurrence:
Hrs_MI"
(mmlddtyy) (Check Selection) RM24_00
From: 16:46 To: 16__01 = 0i 15
Total Volume Flared or Vented: 316 MSCF BELS From: To: _
Planned ❑ Unplanned 91 From: To: _
From: To: _
Meter No: MTR-35012 Total Minutes Flared or Vented = 01:15
(Includes volume flared which generated black smoke, if applicable)
A. Description of Incident and Cause: (Check as many as needed to fully describe the incident)
X S/DT/CM CF-C-32012 X Freese. upset in C3 Module LP Compressor
T/C SD due to high exhaust teap(saWre section of fadi ty
EMERGENCY SHUTDOWN Flaring for Wilsite shutdosin / atanup
X Electrical/ IreWmenlatian malfunction Flare systare testing
ExcessiverinsuMcient inlet gas rales Into facility Faulty shutdown on
Facility Maintenance
Other.
Comments:
LP Compressor shutdown while transitioning Power generation system for facility maintenance for event 16:46 to 78:07
B. Action Taken to Eliminate Cause and Prevent Recumence: (Check and describe as applicable)
facility process and operation
X Started y restarted T/C 9 CF-C-32012 Stabilized facility
Compressor/ train depressured Repaired equipment difficulties
Reduced I increased inlet gas rates with
Facility maintenance completed
Completed flare testing
X Connected E81 fluctuation / failure Other:
Comments:
Stabilized Power system and Restarted LP Compressor
C. Flaring or Venting Was: (Check one(
❑ an emergency that threatened life or property
0 necessary for facility operations, repairs, upgrades, or testing procedures
❑ necessmy to prevent loss of ultimate recovery
Venting Incident
❑ NO: ❑ (1f Yes, complete form a contact Environmental Immediately)
Was the volume over 1,000 meet? Yes:
Flare Incident TRUE
Did incident last for longer than l hour? Yes ❑+ No ❑
If Yea, fax this report to Environmental within 24 hours at KRU- 659-7712 or ALP at 670-4607
Did event cause black smoke > 3 minutes in 1 hr or 6 consecutive minutes? Yes: ❑ No: ❑+
IF Yes, contact Environmental Immediately KRU 669-7242 or ALP 670-4200 and fax this report to Env at KRU- 669-7712 of ALP at 670-4607
(enter tag number and description)
Black smoke' emitted from source:
Date and time of black smoke- event: From: To:
Volume flared which generated black smoke': MSCF _BELS
Description of steps to minimize emissions: (Section B above) Restarted necessary Power General rs f r tan' g the LP Compressor
Material flared: Gas: 316 men NGLs: Other:
General Weather: Air Temperalum: 29F ambient Wind Speed/Direction: 70MPH HE
' Observation by Non-Certified Visible Emission Observer
Based on information and belief formed after reasonable Inquiry, I certify that the statements and Information in and attached to this
document are true, accurate and ce
�1
Date
Facility Supervisor J Sly
L�
cc: Alpine: Field Environmental Compliance Coordinators, ALP-14
Ku arok: Field Environmental Compliance Coordinators, NSK- 61
LP Gas Fla rhV Re"d 0a16174.da
&1&2017
Alpine Environmental
From: Alaska SCADA <AlaskaSCADA@cop.com>
Sent: Thursday, June 15, 2017 6:03 PM
To: ALP SCADA Analyst; Alpine Lead Operators; NSK Env Coord Air Quality &Spill Plans;
Alpine Environmental; ALP Automation
Subject: # ALPINE SCADA: Reportable LP Flare Event
IP21 has recorded a reportable LP Flare event
Flare Event Number: 3797
Flare Event Started: 15 -JUN -1716:45:00.0
Flare Event Ended: 15 -JUN -17 18:00:05.8
Flare Event Duration: 1 Hour, 15 Minutes, 5.8 Seconds
Flare Event Volume: 316.509 (MSCF)
Go to IP21 Flare Event History display (FLAREHLP) for more details.
This email was generated by SQL: FLR_Event on 15 -JUN -17 18:03:04.6
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY: Alpine AIR PERMIT NUMBER: AQ20489TVP01
GAS DISPOSITION
Data of Occurrence: 6/111/2017 Flare Ellet
Time of Occurrence:
(mm/dd/yy) (Check Selection)
0000_DO 2400 HrsMin
From: 21:29 To: 20_41 = 0213
Total Volume Flared or Vented: M44 MSCF BELS
From: To: _ _
Planned ❑ Unplanned P1
From: To: _
From: To: _
Meter No: MTR-35032
Total Minutes Flared erVented 02:15
(Includes volume Cared which generated black smoke, 8 applicable)
A. Description of Incident and Cause: (Check as many as needed to ally desedbe the incident)
SID TIC# for -
Process upset in
TIC SO due to high exhaust Iemparalem
section or facility
EMERGENCY SHUTDOWN
X Flaring for Facillystertup
Electrical / Instrumentation scaguxtlen
Flare system testing
Excessive/insusmAent inlet gas rates into facility
Faulty shutdown on
FaciityMaintenance
X Other: Alpine Fac Startup after Maintenance
Comments:
Alpine Facility wee shut down for annual maintenance. Gas was flared during startup while transitioning to normal operations.
B. Action Taken to Ellmhude Cause and Prevent Recurrence: (Check and describe as applicable)
X Started / restarted TIC # C-33012 HP
X Stabilized facility process and operation
Compressor / train demsesured
Repaired equipment difficulties
Reduced / increased inlet gas Was
with
Completed flare testing
X Facility maintenance completed
Connected E&I fluctuadnn / failure
Other:
Comments:
Total Facility restart
C. Flaring or Venting was: (Check one)
R) necessary for facility operations, repairs, upgrades, or testing procedures
❑ an emergency that threatened Ile or property
❑ m cessa to prevent loss of ultimate recoveni
Venting Incident
Was the volume over 1,000 mscf? Yes: ❑ No: ❑
(If Yea, complete form & contact Environmental Immediately)
Flare Incident
TRUE
Did Incident last for longer than 1 hour? Yes 17 No ❑
It Yes, fax this report to Environmental within 24 hours at KRU- 669-7712 or ALP at 6704507
Did event cause black smoke'> 3 minutes in 1 hr or 6 consecutive minutes? Yes:
❑ No:
If Yes, contact EnAmmental Immediataly KRU 869.7242 or ALP 670.4200 and fax this report to Env
at KRU- 669.7712 or ALP at 6704607
Black smoke emitted from source:
(enter tag number and description)
Date and time of black smoke- event From: To:
Volume flared which generated black smoke':
MSCF _BBLS
Description of steps to minimize emissions: (Section B above)
Motorist flared: Gas: X NGLs:
Omer
General Weather: Air Temparatum: 40F ambient Wind Speed/Direefion: SAWN out of NE
' Observation by Non-Carlified Visible Emission Observer
Based on infoena0on and belief farmed after reasonable Inquiry, I certify that the statements and Information in and attached to this
document are true, accurate and complete.�Q/�fj�� �� /)
Data 4419
Facility Supervisor / 7"J<�'
cc: Alpine: Field Environmental Compliance Coordinators, ALP -14
Ku mk: Field Environmental Compliance Coordinators, NSK-61
LP Gas Flaring Repan 081811 sls
WIM017
Alpine Environmental
From: Alaska SCADA <AlaskaSCADA@cop.com>
Sent: Sunday, June 18, 2017 11:44 PM
To: ALP SCADA Analyst; Alpine Lead Operators; NSK Env Coord Air Quality & Spill Plans;
Alpine Environmental; ALP Automation
Subject: # ALPINE SCADA: Reportable LP Flare Event
Follow Up Flag: Follow up
Flag Status: Flagged
IP21 has recorded a reportable LP Flare event.
Flare Event Number: 3832
Flare Event Started: 18 -JUN -17 21:29:00.0
Flare Event Ended: 18 -JUN -17 23:41:32.2
Flare Event Duration: 2 Hours, 12 Minutes, 32.2 Seconds
Flare Event Volume: 2244.28 (MSCF)
Go to IP21 Flare Event History display (FLAREHLP) for more details.
This email was generated by SQL: FLR_Event on 18 -JUN -17 23:43:52.6
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY: Alpine AIR PERMIT NUMBER: AQ20489TVP01
GAS DISPOSITION
Date of Occurrence: 6/19/2017 Aare ❑/ant Time of Occurrence:
(1nm/cidlyt) (Check SelecOan) 0000 24:00 Hr In
From: 01:22 To: 0260 01:26
Total Volume Flared or Vented: 117 MSCF BBLS From: To: _
Planned ❑ Unplanned 10 From: To: _ _
From: To:
Meter No: MTR - 35012 Total Minutes Flared or vented 012e
(Includes volume flared which generated black smoke. if applicable)
A Description of Incident and Cause: (Check at many as needed to fully describe the Incident)
SAD T/C0 for Process upsets
TIC so a,e a hien..dv a,t temperature section of facility
EMERGENCY SHUTDOWN X Flaring for Facility$WUP
Electrical I Imleumenlaffan malfunction Flare system testing
Exeaealve7nsWficienf inlet gas mica intofacilily Faulty shutdown on
X Fsdlity Maintenance
X Other: Alpine Fac Startup after Maintenance
Comments:
Alpine Facility was shut down for annual malmnence. Gas was flared during startup while transiBoning W normal operations.
B. Action Taken to Eliminate Cauae and Prevent Recurrence: (Check and describe as applicable)
X Started / restarted T/C 6 C-32012 LP Compressor Stabilized facility process and operation
Compressor / train depressured Repaired equipment difficulties
Reduced/ Increased irdat gas rates with
Completed flare testing X Facility maintenance completed
Connoted E6l fluctuation/failure Other. _
Comments:
Total Facility restart
C. Flaring or Venting was: (Check one)
❑+ necessary for facility operations, repairs, upgrades, or testing procedures ❑ an emergency that threatened life or property
❑ necessary to prevent loss of ultimate recovery
Venting Incident
Was the volume over 1,000 meet? Yes: ❑ No: ❑ (If Yea, complete form A contact Environmental immediately)
Flare Incident TRUE
Did incident last for longer than 1 hour? Yes ❑+ No ❑
If Yes, fax this report to Environmental within 24 boom at KRU- 659.7712 or ALP at 6704607
Did event rause black smoke > 3 minutes In 1 or or 6 consecutive minutes? Yes: ❑ No: ❑'
If Yes, contact Environmental immediately KRU 659-7242 or ALP 670.4200 and fax this report to Env at KRU- 969-7712 or ALP at 6704607
Black smoke' emitted from source: (enter lag number and deacriplbn)
Dale and time of black smoke* event: From: TV..
Volume flared which generated black smoke': MSCF BBLS
Description of steps to minimize emissions: (Section B above)
Material flared: Gas: X NGLs: Other:
General Weather: Air Temperature: Wind Speed/Direction:
• Observation by Non -Certified Visible Emission Observer
Based on Information and belief farmed after reasonable inquiry, I certify that the statements and information in and attached to this
document ere true, accurate and complete.
Date
Facility Supervisor
cc: Alpine: Field Environmental Compliance Coordinators, ALP -14
Ku amk: Field Environmental Compliance Coordinators, NSK- 61
LP Fas Flaring Report 0a191].ds
Wig/2017
Alpine Environmental
From: Alaska SCADA <AlaskaSCADA@cop.com>
Sent: Monday, June 19, 2017 2:53 AM
To: ALP SCADA Analyst; Alpine Lead Operators; NSK Env Coord Air Quality & Spill Plans;
Alpine Environmental; ALP Automation
Subject: # ALPINE SCADA: Reportable LP Flare Event
IP21 has recorded a reportable LP Flare event
Flare Event Number: 3838
Flare Event Started: 19 -JUN -1701:22:00.0
Flare Event Ended: 19 -JUN -17 02:50:34.7
Flare Event Duration: 1 Hour, 28 Minutes, 34.7 Seconds
Flare Event Volume: 117.018 (MSCF)
Go to IP21 Flare Event History display (FLAREHLP) for more details.
This email was generated by SQL: FLR_Event on 19 -JUN -17 02:53:19.5
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. MonthNearof Disposition
July -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
volume.
6. Sold
33,454
Pool Name Pool Code Percent
7. Reinjected
1,706,782
ALPINE 120100 74.3%
FIORD 120120 16.5%
8. Flared or vented 1 hour or less
15,928
NANUQ 120175 2.13%
NANUQ-KUPARUK 120100 5.2%
9. Flared or vented more than 1 hour (see instr.)
0
QANNIK 120180 27;
OTHER Undefined 0.07/
10. Pilot and Purge
5,557
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
398,426
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6.13)
2,170,147
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
Commissioner Date
18. Transferred to: (Express as a negative #)
19. Remarks: Gas sold to Alpine Transportation Company = 28,678
Gas gifted to Village of Nuiqsut =4,776
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature: ✓ ��� Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 ° F. Authority 20
AAC25.235.
Printed Name: Diane Hendrickson Phone: Date: August 20, 2017
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
JUN]
Total Flare> 1 Hour
Total Flare <=1 Hour 15.928
Pilot and Purge 15.557
Total Flare 31.485
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. Mon#VYear of Disposition
August -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
38,680
Pool Name Pool Code Percent
7. Reinjected
1,817,152
ALPINE 120100 65.8%
FIORD 120120 15.9%
8. Flared or vented 1 hour or less
4,308
NANUO 120175 2.2%
NANUO-KUPARUK 120100 14.3%
9. Flared or vented more than 1 hour (see ins[r.)
0
QANNIK 120180 1.8%
OTHER Undefined 0.0%
10. Pilot and Purge
11,801
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
418,479
13. Other (see instructions)_
- -
Authorization >7 hr:
Official Use Only
Safety
MCF
14. TOTAL VOLUME (ITEMS6-13)
2,290,420
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste.
MCF
17. Transferred from:
Commissioner Date
18. Transferred to: (Express as a negative #)
19. Remarks: Gas sold to Alpine Transportation Company = 30,836
Gas gifted to Village of Nuiqsut =7,844
I hereby certify that the Foregoing is true and correct to the best of my knowledge.
9''� Note: All volumes must be corrected to
Signature: Z;)Zt /i.Q �/Jj Title: Revenue & Regulatory Analyst pressure of 14.65 psia and to a
temperature of 600F. Authority 20
Printed Name: Diane Hendrickson Phone: Date: September 20, 2017 AAC25.235.
Form 10-422 Rev. 5/2009 - INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Aug -17
DATE
START
TIME
DATE
END
TIME
PLANNED
UNPLANNED
VOLUME
MSCF
DESCRIPTION OF FLARING EVENT
ACTION TAKEN TO MINIMIZE VOLUME
Total Flare>1 Hour 0
Total Ftare<=1 Hour 4.308
PllotanAPur9e 11,801
Total Flare 16,109
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. MonthNear of Disposition
September -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
38,208
Pool Name Pool Code Percent
7. Reinjected
1.694,178
ALPINE 120100 66.5%
FIORD 120120 17.7%
8. Flared or vented 1 hour or less
2,396
Ni 120175 2.4%
NANUO-KUPARUK 120100 11.7%
9. Flared or vented more than 1 hour (see instr.)
0
QANNIK 120180 1.8%
OTHER Undefined 0.0%
10. Pilot and Purge
9,345
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
415,149
13. Other (see instructions)
Official Use Only
Authorization 11 hr:
Safety
MCF
14. TOTAL VOLUME (BEMs 6-13)
2,159,276
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
Commissioner Date
18. Transferred to: (Express as a negative #)
19. Remarks: Gas sold to Alpine Transportation Company = 29,725
Gas gifted to Village of Nuiqsut =8,483
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
j� Note: All volumes must be corrected to
Signature: ✓ �� ��� Title: Revenue & Regulatory Analyst pressure of 14.65 psia and to a
temperature of 60°F. Authority 20
Printed Name: Diane Hendrickson Phone: Date: October 20, 2017 AAC25.235.
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
SeP 1T
DATE
START
TIME
DATE
END
TIME
PLANNED
UNPLANNED
VOLUME
MSCF
DESCRIPTION OF FLARING EVENT
ACTION TAKEN TO MINIMIZE VOLUME
Total Flare> 1 Hour a
Total Flare e.1 Hour 2.396
Pilota.d Porge 9.345
Total Flare 11,741
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. Monthlyear of Disposition
October -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
39,410
Pool Name Pool Code Percent
7. Reinjected
1,682,603
ALPINE 120100 67.47/
FIORD 120120 15.031.
B. Flared or vented 1 hour or less
1,734
NANUO 120175 2.4%
NANUQ-KUPARUK 120100 13.5%
9. Flared or vented more than 1 hour (see instr.)
0
OANNIK 120180 1.8%OTHER0.0
Untlefinetl %
10. Pilot and Purge
9.920
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
442,946
13. Other (see instructions)
Official Use Only
Authorization>1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 613)
2,176,613
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Gas sold to Alpine Transportation Company = 30,500
Gas gifted to Village of Nuiqsut =8,910
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature: Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60°F. Authority 20
AAC25.235.
Printed Name: Diane Hendrickson Phone: Dale: November 20, 2017
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
On -1]
DATE
START
TIME
DATE
END
TIME
PLANNED
UNPLANNED
VOLUME
MSCF
DESCRIPTION OF FLARING EVENT
ACTION TAKEN TO
MINIMIZE VOLUME
Total Flare> 1 Hour
Total Flare <-1 Hour 1,734
Pilot and Purge 9,920
Total Flare 11,654
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1030000017
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. Month/Vear of Disposition
November -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
41,092
Pool Name Pool Cade Percent
7. Reinjected
1,511,047
ALPINE 120100 69.03%
FIORD 120120 13.4%
8. Flared or vented 1 hour or less
3,992
NANUQ 120175 2.2%
NANUQ-KUPARUK 120100 14.1%
9. Flared or vented more than 1 hour (see instr.)
0
QANNIK 120180 1.2%
OTHER Undefined 0.0%
10. Pilot and Purge
13,648
11. Assist Gas
100.0%
12. Fuel gas used in lease operations.
449,653
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6.13)
2,019,432
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Gas sold to Alpine Transportation Company = 29,729
Gas gifted to Village of Nuiqsut =11,363
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
tu: f/l.V/%/'j.Q. Q%�/1i Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psis and to a
temperature of 60°F. Authority 20
AAC25.235.
rPntd.dNarn,: Diane Hendrickson Phone: Date: December 20, 2017
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Nov -17
Total Flare> 1 Hour 0
Total Flare <=1 Hour 3,992
PilotanCPurge 13,648
Total Flare 17,640
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1 0 3000001 7
2. Facility Name
Colville River Unit Processing Facility
3. Field
Colville River Unit
4. Operator
CONOCOPHILLIPS ALASKA, INC.
5. MonthNear of Disposition
December -17
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
44,219
Pool Name Pool Code Percent
7. Reinjected
1,521,693
ALPINE 120100 71.2%
FIORD 120120 11.3%
8. Flared or vented 1 hour or less
1,182
NANUO 120175 2.4%
NANUO-KUPARUK 120100 14.2%
9. Flared or vented more than 1 hour (see instr.)
0
OANNIK 120180 0.9%
OTHER0.0%
Undefined
10. Pilot and Purge
14,575
11. Assist Gas
00.0%
12. Fuel gas used in lease operations.
468,985
13. Other (see instructions)
Official Use Only
Authorization>1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS &13)
2,050,654
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Gas sold to Alpine Transportation Company = 31,978
Gas gifted to Village of Nuiqsut = 12,241
1 hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature: �GCr.>+Z2 6��l1.8II1i Title: Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60°F. Authority 20
AAC25.235.
Printed Name: Diane Hendrickson Phone: Date: January20, 2018
Form 10-422 Rev. 5/2009 IN5TRUCFIONS ON REVERSE SIDE Submit in Duplicate
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Dea17
Total Flare > 1 Hour
Total Flare<=1 Hour Mu
Pilot and Purge 14,575
Total Flare 15.757