Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU GC 1 - BP Exploration (Alaska), Inc.State of Alaska AOGCC Gas Disposition Files Year: 2017 Facility: PBU GC 1 Operator: BP EXPLORATION (ALASKA) INC.     STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. FacilityNumber2. 0290000031 Facility Name PBU GC 1 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition I January -2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold O Pool Name Pool Code Percent 7. Reinjected O PRUDHOE 640150 97,39% LISBURNE 640144 0.26% 8. Flared or vented lhour or less 9 MIDNIGHT SUN 640158 0.08%,205 PT MCINTYRE 640180 2.27% 9. Flared or vented more than 1 hour (see instr.) 2,865 10. Pilot and Purge 53,809 11. Assist Gas 0 12. Fuel gas used in lease operations. 816,331 13. Other (see instructions) 0Authorization Official Use Only >1 hr: Safety 2 6 4� 5- MCF 14. TOTAL VOLUME (ITEMS 6-12) 882,210 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 3 Commissioner Date 18. Transferred to: (Express as a negative #) CGF -72,518,466 19. Remarks: I hereby certify thatth foregoing its true and correct to the best of my knowledge. (Cl'l ��'I Note: All volumes must be corrected Signature t,t r u �(G I Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date " AAC25.235. i Ti- )'? 1 P Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT January 2017 1/1/2017 0135-0207 410 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 1/1/2017 0829-0927 1,410 2,865 1/1/2017 2114-2139 1,060 exceeding 5,000 MCF 1/2/2017 0325-0405 1,740 0 1/15/2017 1059-1107 100 Pilot Purge 1/19/2017 0845-0847 4 0 1/21/2017 1614-1615 2 1/23/2017 1815-1858 4,479 TOTAL 9,205 Unplanned events greater than 1 hour DATE TIME 1/1/2017 VOLUME DESCRIPTION OF INCIDENT &CAUSE ACTION TAKEN TO ELIMINATE CAUSE 0105-2359 1,800 See attachments See attachments 1/2/2017 0333-2359 713 1/10/2017 1457-2245 166 1/29/2017 0830-1357 186 TOTAL 2,865 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See attachments See attachments TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See attachments See attachments TOTAL 0 Page 6 2/12/2017 5:13 PM TOTAL Unplanned Events < 1 Hour 9,205 Unplanned Events> 1 Hour 2,865 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 53,809 Assist 0 TOTAL FLARED VOLUME 65,879 Page 6 2/12/2017 5:13 PM Flare Start Date 01/01/2017 Flare End Date 01/31/2017 GCI Flare Report Total Volume (MSCF) 12070 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-2 Flare Relief 01/01/2017 1:05:00 am 11:59:00 pm 1374 min Yes No No BPIkLOTTTO 1800 Determination Cause High gas transit line pressure Action Taken WOA stopped bringing production rates up. reduced rates until Baring stopped. 17-5 Flare Relief 01/02/2017 3:33:00 am 11:59:00 pm 1226 min Yes No No BPIILOTTTO 713 Determination Cause High gas transit line pressure Action Taken No response taken as this was deemed to be of short duration. Daily Volume (MSCF) 2453 17-19 Flare Relief 01/10/2017 2:57:00 pm 10:45:00 pm 468 min Yes No No BPIISPRINGG 166 Determination Cause Unstable process Action Taken Process stabilized Daily Volume (MSCF) 166 Generated 02102/2017 11:09:42AM Page 5 of 8 Flare Start Date 01/01/2017 Flare End Date 01/31/2017 17-37 Flare Relief 01/29/2017 8:30:00 am 1:57:00 pm 327 min Yes No No BP1\SPRINGG 186 Determination Cause High gas transit line pressure Action Taken No response taken as this was deemed to be of short duration. Daily Volume (MSCF) 186 Total Volume (MSCF) 12070 Generated 02/02/2017 11:09:42AM Page 6 of 8 A flaring event occurred at GC1 starting at 01/01/2017 01:05 and stopping at 01/01/2017 23:59 with a volume of 1800 (MSCF). The event was intermittent, lasted for 1374 minutes, and was due to high transit gas pressure. The flaring event stopped when the gas transit pressure was lowered. A flaring event occurred at GC1 starting at 01/02/2017 03:33 and stopping at 01/02/2017 23:59 with a volume of 713 (MSCF). The event was intermittent, lasted for 1226 minutes, and was due to high transit gas pressure caused by CGF's 1&2 boosters tripping offline. The flaring event stopped when the gas transit pressure was lowered. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blake@bp.com Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Wednesday, January 04, 2017 12:29 PM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Schinagl, Werner, Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GCI Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GCI To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc. reportingt7a.alaska.gov Victoria. loepp(cbalaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring ev\tran rred at GC1 starting at 11/30/2016 11:04 and stopping at 11/30/2016 15:16 with a volume of 64 (MSCFvent lasted for 252 minutes and was due to high gas transit line pressure. The flaring event stopped when the gt pressure was lowered. A flaring event occurre4,at GC1 starting at 12/02/2016 08:06 and stopping at 12/02/2016 11:37 with a volume of 113 (MSCF). The event ted for 211 minutes and was due to large oil swings through the Annex. The flaring event stopped when rates stabilized. A flaring event occurred at GC1 starts at 12/07/2016 14:34 and stopping at 12/07/2016 16:24 with a volume of 750 (MSCF). The event lasted for 11 inutes and was due a shutdown of A Bank. The flaring event stopped when rates were reduced and A bank was restarte A flaring event occurred at GC1 starting at 12/12/ 16 14:06 and stopping at 12/12/2016 19:24 with a volume of 225 (MSCF). The event was intermittent, lasted for 318 rn utes, and was due to spurious actuation of the LP Flare Valve. The intermittent flaring event stopped without intervention and a work order was submitted to calibrate the high pressure switch controlling the valve.. A flaring event occurred at GCI starting at 12/13/2016 01:4 and stopping at 12/13/2016 13:11 with a volume of 128 (MSCF). The event was intermittent, lasted for 688 minutes, d was due to spurious activation of the LP Flare Valve. The intermittent flaring event stopped and the pressure switch was librated. A flaring event occurred at GC1 starting at 12/15/2016 21:20 and stppping at 12/15/2016 22:59 with a volume of 1450 (MSCF). The event lasted for 99 minutes and was due to flaring off the IP/HP gas system as a result of a Stop Production caused by a UPS power glitch. The flaring event stopped when the UP power was restored. A flaring event occurred at GC1 starting at 12/15/2016 21:29 and stopping*t 12/15/2016 23:03 with a volume of 128 (MSCF). The event lasted for 94 minutes and was due to intermittent flaring 6 the LP gas system as a result of a Stop Production caused by a UPS power glitch. The flaring event stopped when the PS power was restored. A flaring event occurred at GC1 starting at 12/19/2016 08:00 and stopping at 12/19 016 10:00 with a volume of 37500 (MSCF). The event lasted for 120 minutes and was due to the Annex reboiler shutdo n for combustion blower filter inspection. The flaring event stopped when the reboiler was placed back in service. A flaring event occurred at GC1 starting at 12/29/2016 04:17 and stopping at 12/29/2016 23:59 with a volume of 553 (MSCF). The event was intermittent, lasted for 1182 minutes, and was due to high transit gas pressure. The flaring event stopped when the gas transit pressure was lowered. A flaring event occurred at GC1 starting at 12/31/2016 00:34 and stopping at 12/31/2016 23:58 with'a volume of 1000 (MSCF). The event was intermittent, lasted for 1182 minutes, and was due to high transit gas pressur The flaring event stopped when the gas transit pressure was lowered. Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Tuesday, February 07, 2017 7:45 AM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, Schinagl, Werner; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc. reporting Qalaska.gov Victoria. IoeppCa.alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 01/29/2017 08:30 and stopping at 01/29/2017 13:57 with a volume of 186 (MSCF). The event was intermittent for the duration of 327 minutes. The event was due to high transit gas line pressure. The flaring event stopped when the ambient temperatures dropped and the transit gas line pressure reduced. A flaring event occurred at GC1 starting at 02/04/2017 04:45 and stopping at 02/04/2017 17:47 with a volume of 886 (MSCF). The event was intermittent for the duration of 782 minutes. The event was due to high transit gas line pressure. The flaring event stopped when the ambient temperatures dropped and the transit gas line pressure reduced. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blakePbp.com STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 0290000031 PBU GC 1 Disposition 3. Field PBU - WOA Volume MCF 4. Operator 5. MonlhNear of Disposition BP I February -2017 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold URMIDNIGHTSUN Pool Code Percent 7. Reinjected U 640150 97.64% 640144 0.25% 8. Flared or vented 1 hour or less U 640158 0.10% 640180 201% 9. Flared or vented more than 1 hour (see instr.) 24,857 10. Pilot and Purge 48,260 11, Assist Gas 0 12. Fuel gas used in lease operations. 733,474 13. Other (see instructions) 0 Official Use Only Authorization>1 hr Safety Z ^ `� f� J MCF 14. TOTAL VOLUME (ITEMS 6-12) $06,591 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 18. Transferred to: (Express as a negative #) CGF -66,554,400 Commissioner Date 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. �� Note: Ali volumes must be corrected Signature_ Title Manager Production Taxes and Ro alties Alaska to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date AAC25.235. V^ "TL� 4 / -1 1 (7 --- Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate TOTAL U BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT -GC -1 GAS FLARING INCIDENT REPORT February 2017 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr junplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 2/4/2017 0445-0547 886 See attachments See attachments 2/15/2017 1100-1300 100 2/25/2017 0203-0248 23,871 TOTAL 24,857 See attachments TOTAL 0 DESCRIPTION OF IN See attachments TOTAL 0 See attachments See attachments Page 8 3/15/2017 10:10 AM TOTAL Unplanned Events < 1 Hour 0 Unplanned Events 1 Hour 24,857 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events> 1 hour or 0 exceeding 5,000 MCF Pilot Purge 48,260 Assist 0 TOTAL FLARED VOLUME 73,117 See attachments See attachments Page 8 3/15/2017 10:10 AM Flare Start Date 02/012017 Flare End Date 02/28/2017 GCI Flare Report Total Volume (MSCF) 24857 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-39 Flare Relief 02/04/2017 4:45:00 am 5:47:00 pm 782 min Yes No No BPIISPRINGG 886 Determination Cause High gas transit line pressure Action Taken No response taken Daily Volume (MSCF) 886 17-50 Flare Relief 02/15/2017 11:00:00 am 1:00:00 pm 120 min Yes No No SP1\FUELMO 100 Determination Cause High transit gas pressure, caused intermittent flaring off of V-136 Action Taken Transit gas pressure taken down and intermittent flaring stopped. Daily Volume (MSCF) 100 17-62 Flare Relief 0225/2017 2:03:00 am 2:48:00 pm 765 min No No No BP1\SPRINGG 23871 Determination Cause Had a Power Supply Failure in SK -18 Action Taken Equipment was restarted Daily Volume (MSCF) 23871 Total Volume (MSCF) 24857 Generated 03/01/2017 3:11:04PM Page 8 of 9 Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Friday, February 24, 2017 3:00 PM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Schinagl, Werner; Barton, Kim; AK, HSSEE Env Adv West; AK, OPS GCI Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting(a)alaska.gov Victoria.loepp(a)alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 02/15/2017 11:00 and stopping at 02/15/2017 13:00 with a volume of 100 (MSCF). The event was intermittent over a 120 minutes duration and was due to high gas transit line pressure. The flaring event stopped when the gas transit pressure was lowered. Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell(907)830-6204 Jennifer.blake(@bp.com Link, Liz M (DOA) From: AKOpsProcIEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Thursday, March 16, 2017 1:49 PM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Schinagl, Werner; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Event at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc. reporting(a)alaska. gov Victoria. loepp(a)alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GCI starting at 02/25/2017 02:03 and stopping at 02/25/2017 14:48 with a volume of 23871 (MSCF). The event lasted for 765 minutes and was due to power supply failure in Skid 18, which is the LP/IP Compressor skid. The flaring event stopped when the equipment was repaired and the affected process was restarted. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blake Cdbp.com Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Tuesday, February 07, 2017 7:45 AM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Schinagl, Werner; Barton, Kim; AK, HSSEE Env Adv West; AK, OPS GCI Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GCI To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aoncc.reporting( alaska.gov Victoria. loepp(a)alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 01129/2017 08:30 and stopping at 01/29/2017 13:57 with a volume of 186 (MSCF). The event was intermittent for the duration of 327 minutes. The event was due to high transit gas line pressure. The flaring event stopped when the ambient temperatures dropped and the transit gas line pressure reduced. A flaring event occurred at GC1 starting at 02/04/2017 04:45 and stopping at 02/04/2017 17:47 with a volume of 886 (MSCF). The event was intermittent for the duration of 782 minutes. The event was due to high transit gas line pressure. The flaring event stopped when the ambient temperatures dropped and the transit gas line pressure reduced. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blake@bp.com STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000031 2. Facility Name PB GC 1 3. Field PBU - WOA 4. Operator BP 5. MonthlYear of Disposition March -2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6 Sold Pool Name Pool Code Percent 7. Reinjected O PRUDHOE 640150 97.62% LISBURNE 640144 0.25% 8. Flared or vented lhour or less 1897 MIDNIGHT SUN 640158 0,04%j,897 MCINTYRE 640180 2.09% 9. Flared or vented more than 1 hour (see instr.) 725 10. Pilot and Purge 53,594 11, Assist Gas 0 12. Fuel gas used in lease operations. 807,353 13. Other (see instructions) 0Official Use Only Authorization>1 hr: Safety —725— MCF Ij � 5-1/ 14. TOTAL VOLUME (ITEMS 6-12) 863,569 Lease Use MCF 15. NGL Gas Equivalent 0 ConservationMCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 O o �L 18. Transferred to: (Express as a negative #) CGF -72,462,316 Commissioner Date 19. Remarks: I hereby certify that th foregoing is true and correct to the best of my knowledge. �h� C44�(lQC Note: All volumes must be corrected Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psis and to a "temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT March 2017 junplanneo events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 3/15/2017 0452-0504 1,567 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 3/21/2017 1753-1832 40 TOTAL 1,607 3/30/2017 3/31/2017 0125-2210 0125-2010 TOTAL 568 See attachments 157 725 See attachments 3/1/2017 1705-1710 70 See attachments See attachments 3/7/2017 2054-2058 20 3/8/2017 0050-0054 120 3/26/2017 1334-1338 80 TOTAL 290 Planned events Qreater than 1 hour TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 0 TOTAL 1,607 725 290 0 53,594 0 56,216 See attachments See attachments Page 7 4/13/2017 10:32 AM Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Monday, April 10, 2017 11:09 AM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory, Schinagl, Werner; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL, AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting (a)alaska.gov Victoria. loepp(o)alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 03/30/2017 01:25 and stopping at 03/30/2017 22:10 with a volume of 568 (MSCF). The event lasted for 1245 minutes and was intermittent in nature. It was due to high gas transit line pressure. The flaring event stopped when the transit line pressure was reduced. A flaring event occurred at GC1 starting at 03/31/2017 01:25 and stopping at 03/31/2017 22:10 with a volume of 157 (MSCF). The event lasted for 1245 minutes and was intermittent in nature. It was due to high gas transit line pressure. The flaring event stopped when the transit line pressure was reduced. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer. bla ke@bp.com Flare Start Date 03/01/2017 Flare End Date 03/3112017 GC1 Flare Report Total Volume (MSCF) 2622 Report Numbe System Date StartTime Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-69 Flare Relief 03/01/2017 5:05:00pm 5:10:00 pm 5min No No Yes BP1\SPRINGG 70 Determination Cause Swapped GLT machines Action Taken No response taken as this was deemed to be of short duration. Daily Volume (MSCF) 70 17-77 Controlled Blowdown 03/07/2017 10:54:00 pm 10:58:00 pm 4 min No No Yes BP1\SPRINGG 20 Determination Cause Swapped GLT machines Action Taken swap complete Daily Volume (MSCF) 20 17-78 Controlled Slowdown 03/08/2017 12:50:00 am 12:54:00 am 4 min No No Yes BP1\SPRINGG 120 Determination Cause Depressured GLT3200 , Action Taken depressure complete Daily Volume (MSCF) 120 17-96 Controlled Blowdown 03/26/2017 1:34:00 pm 1:38:00 pm 4 min No No Yes BP1\SPRINGG 80 Determination Cause Swapped GLTmachines Action Taken depressured Daily Volume (MSCF) 80 17-100 Flare Relief 03/30/2017 1:25:00 am 10:10:00 pm 1245 min Yes No No BP1\SPRINGG 568 Determination Cause High gas transit line pressure Action Taken No response taken Daily Volume (MSCF) 568 17-101 Flare Relief 03/31/2017 1:25:00 am 10:10:00 pm 1245 min Yes No No BP1\SPRINGG 157 Determination Cause High gas transit line pressure Action Taken No response taken Daily Volume (MSCF) 157 Total Volume (MSCF) 2622 Generated 04/03/2017 4:36:08PM Page 6 of 7 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number2. 0290000031 Facility Name PBU GC 1 3. Field PBU - WOA 4. Operator BP 5. Month/Year of Disposition I April -2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected O PRUDHOE 640150 97.48% LISBURNE 640144 0.27% 8. Flared or vented 1 hour or less 168 MIDNIGHTSUN 640158 0.05% PT MCINTVRE 640180 2.20% 9. Flared or vented more than 1 hour (see insti.) 0 10. Pilot and Purge 50,695 11, Assist Gas 12. Fuel gas used in lease operations. 840,625 13. Other (see instructions) 0 Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 891,488 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 Commissioner Date 18. Transferred to: (Express as a negative #) CGF -69,580,070 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. /6P, Note: All volumes must be corrected Signature r"" u'c7 ,//,/"`�" Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date�Ah AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT April 2017 junplanneo events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 4/10/2017 0945-1000 120 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 4/17/2017 1454-1459 38 TOTAL 158 Page 7 5/14/2017 2:06 PM See attachments See attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 4/21/2017 1951-1953 10 See attachments See attachments TOTAL 10 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See attachments See attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 158 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 10 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 50,695 Assist 0 TOTAL FLARED VOLUME 50,863 Page 7 5/14/2017 2:06 PM Flare StartDate 04/0112017 Flare End Date 04/30/2017 GCI Flare Report Total Volume (MSCF) 166 Report Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-130 Controlled Blowdown 04/21/2017 7'.51:00 pm 7.53:00 pm 2 min No No Yes 3P1WRINGG 10 Determination Cause Started up GLT-3300 (purged) Action Taken No response taken as this was deemed to be of short duration. Daily Volume (MSCF) 10 Total Volume (MSCF) 166 Generated 05/02/2017 1.16.36PM Page 8 of 10 Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Tuesday, May 2, 2017 5:20 PM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Schinagl, Werner; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Event at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting[7c alaska.gov Victoria. loepp ccDalaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 05/01/2017 22:00 and stopping at 05/02/2017 00:00 with a volume of 110 (MSCF). The event lasted for 120 minutes and was due to spin cooling LPS compressor K-7000 for water wash. The flaring event stopped when the spin cooling was complete. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell(907)830-6204 Jennifer.blake@bp.com STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PROnLICFn me nicpnciTink, - 1. Facility Number 2. Facility Name 0290000031 PBU GC 1 Disposition --------- 3. Field PBU - WOA Volume MCF --.- -.V. VV, ..V.. 4. Operator 5. Monlh/Year of Disposition BP May -2017 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold U Pool Name Pool Code Percent 7, Reinjected 0 PRUDHOE 640150 97,19/ LISBURNE 640144 027% 8. Flared or vented 1 hour or less 9 850 MIDNIGHT SUN 640158 0,04%,850 MCINTYRE 640180 2.50% 9. Flared or vented more than 1 hour (see instr.) 5,037 10. Pilot and Purge 52,353 11. Assist Gas U 12. Fuel gas used in lease operations. 802,977 13. Other (see instructions) Q Official Use Only Authorization >1 hr: Safety JSl� 3 7 MCF :� 1,`)9) 14. TOTAL VOLUME (ITEMS 6-12) 870,217 Lease Use MCF 15, NGL Gas Equivalent U Conservation MCF 16. Purchased gas U Waste: MCF 17. Transferred from. n 18. Transferred to: (Express as a negative #) CGF -68,858,865 Commissioner Date 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. �'uJ (,l Note: All volumes must be corrected Signature_ Title Manager Production Taxes and Ro alties Alaska to pressure of 14.65 psia and to a Printed Name Diane Calle temperature of 60o F. Authority 20 Y Phone (907) 564-5775 Date AAC25.235. Form 10-422 Rev. 512009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate SP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT May 2017 5/3/2017 2000-2100 833 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 5/7/2017 1015-1020 90 5/9/2017 0746-0819 8,062 5/12/2017 1734-1744 5 5/13/2017 0522-0527 30 5/17/2017 1824-1837 150 5/26/2017 0756-0849 150 TOTAL 9,320 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5/14/2017 1548-1825 3,460 See attachments See attachments TOTAL 3,460 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5/3/2017 1048-1123 250 See attachments See attachments 5/5/2017 1055-1129 180 5/29/2017 0427-0433 90 5/29/2017 0731-0741 10 TOTAL 530 Planned events greater than i hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5/1/2017 2200-2400 110 See attachments See attachments 5/9/2017 1416-1601 1,467 TOTAL 1,577 TOTAL Unplanned Events < 1 Hour 9,320 Unplanned Events> 1 Hour 3,460 Planned Events < 1 hour and not 530 exceeding 5,000 MCF Planned Events> 1 hour or 1,577 exceeding 5,000 MCF Pilot Purge 52,353 Assist 0 TOTAL FLARED VOLUME 67,240 Page 6 6/14/2017 1'.58 PM Flare StartDate 05/01/2017 Flare End Date 05/3112017 GC1 Flare Report Total Volume (MSCF) 14887 Report Numbe System Date StartTime Stop Time Duration Intermittent Black Smoke Planned Reported By Volume t i -t 3fi Other 05/01/2017 10:00:00 pm 12:00:00 am 120 min Yes Determination Cause K-7000 spin cool for h2o wash Action Taken none, planned event 17-139 Flare Relief 05/03/2017 10:48:00 am 11:23:00 am 35 min No Determination Cause Use offuel gas to tum coppus for K-7000 water wash Action Taken Flaring stopped once the wash was done 17-140 Flare Relief 05/05/2017 10:55:00 am 11:29:00 am 34 min No Determination Cause Use of fuel gas to tum coppus for K-7001 water wash Action Taken Flaring sloped once water wash was done 17-151 Flare Relief 05/09/2017 2:16:00 pm 4:01:00 pm 105 min No Determination Cause Depressured Y/P-LDF through "B" Slugcatcher at GC1 for UDF repair. for Repair Action Taken Line was completed depressured allowing work to take place No Yes BP7\KIRSCHW 110 Daily Volume (MSCF) 110 No Yes BPt\SHELT1 250 No Yes BP1\SHELTI 180 No 17-172 Flare Relief 05/14/2017 3:48:00 pm 6:25:00 pm 157 min No No Determination Cause K-7000 shutdown on a gas sensor that malfunctioned. It was showing a high gas alar. Action Taken Flaring stopped once rates were cut Generated 06/0912017 2:22:08PM Daily Volume (MSCF) 180 Yes BP1\DELATI 1467 Daily Volume (MSCF) 9529 No BPI\SHELTI Daily Volume (MSCF) 3460 3460 Page 6 of 9 Flare StartDate 05/01/2017 Flare End Date 05/31/2017 High gas transit line pressure. Flared off D tat stage 17-185 Controlled Blowdown 05/29/2017 4:27:00 am 4:33:00 am 6 min No No Yes BP1I,SPRINGG 90 Determination Cause GLT compressor K-3300 shut down/depressured for H2o wash Action Taken depressured 17-185 Controlled Blowdl w 05/29/2017 7:31:00 pm 7:41:00 pm 10 min No No Yes BMSPRINGG 10 Determination Cause Started up GILT 3300 after watenvash (PURGE) Action Taken start-up complete Daily Volume (MSCF) 100 Total Volume (MSCF) 14887 Generated 06/09/2017 2:22:08PM Page 7 of 9 Link, Liz M (DOA) From: AKOpsProcIEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Thursday, May 18, 2017 12:08 PM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Schinagl, Werner; Barton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A; Dean, James A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc. reporting(o)alaska.gov Victoria. loepp()alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 05/09/2017 07:46 and stopping at 05/09/2017 08:19 with a volume of 8062 (MSCF). The flaring event was due to high gas transit pressure when CGF lost a booster compressor. The flaring event stopped when CGF restarted the booster compressor and gas transit pressures dropped. A flaring event occurred at GC1 starting at 05/09/2017 14:16 and stopping at 05/09/2017 16:01 with a volume of 1467 (MSCF). The event lasted for 105 minutes and was due to depressurizing Y/P LDF through the B Slug Catcher for planned LDF repair. The flaring event stopped when depressurization was completed. A flaring event occurred at GC1 starting at 05/14/2017 15:48 and stopping at 05/14/2017 18:25 with a volume of 3460 (MSCF). The event lasted for 157 minutes and was due to K-7000 compressor shutting down from a malfunctioning gas sensor. The flaring event stopped when rates were cut. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blake@bp.com FlareStartDate 05/01/2017 Flare End Date 05/31/2017 GCS Flare Report Total Volume (MSCF) 14887 Report Numbe System Date StartTime Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-136 Other 05/01/2017 10:00:00 pm 12:00:00 am 120 min Yes No Determination Cause K-7000 spin cool for h2owash Action Taken none, planned event 17-139 Flare Relief 05/03/2017 10:48:00 am 11:23:00 am 35 min No No Determination Cause Use of fuel gas to tum coppus for K-7000 water wash Action Taken Flaring stopped once the wash was done 17-140 Flare Relief 05/05/2017 105500 am 11:29:00 am 34 min No No Determination Cause Use of fuel gas to tum ceppus for K-7001 water wash Action Taken Flaring sloped once water wash was done 17-151 Flare Relief 05/09/2017 2:16:00 pm 4:01:00 pm 105 min No Determination Cause Depmssured Y/P-LDFthmugh"B" Slugcatcherat GCl for LDF repair. for Repair Action Taken Line was completed depressured allowing work to take place Yes BPl\KIRSCHW 110 Daily Volume (MSCF) 110 Yes BP1\SHELTI 180 Daily Volume (MSCF) 180 No Yes BPI\DELATI 1467 17-172 Flare Relief 05/14/2017 3:48:00 pm 6:25:00 pm 157 min No No Determination Cause K-7000 shutdown on a gas sensor that malfunctioned. It was showing a high gas alarm. Action Taken Flaring stopped once rates were cut Daily Volume (MSCF) 9529 No BP1\SHELTI 3460 Daily Volume (MSCF) 3460 Generated 06/09/2017 2:22:08PM Page 6 of 9 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000031 2. Facility Name PBU GC 1 3. Field PBU - WOA 4. Operator BP 5. Month/Year of Disposition I June -2017 Disposition Volume MCF 20. For production fmm multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected U PRUDHOE 640150 97.39% LISBURNE 640144 0.30% 8. Flared or vented 1 hour or less 700 MIDNIGHT SUN 640158 0.05°/PT MCINTYRE 640180 2.26% 9. Flared or vented more than 1 hour (see instr.) 3,910 10. Pilot and Purge 50,295 11. Assist Gas 0 12. Fuel gas used in lease operations. 810,847 13. Other (see instructions) U Official Use Only Authorization >11 hr: Safety 3 y, b MCF 14. TOTAL VOLUME (ITEMS 6-12) 865,752 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas UMCF Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #) CGF -65,270,288 Commissioner Date 19, Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. 9 1/A y)n Note: All volumes must be corrected Signature �(.Wf lk Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date AAC25.235. V TL /°!1il /t Form 10422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRU DHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT June 2017 unplanned events less than or equal to 1 hour 0452-0457 DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 6/4/2017 1252-1256 40 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 6/5/2017 1507-1513 60 6/20/2017 2159-2210 50 6/22/2017 0928-0933 80 6/23/2017 0850-0853 230 TIME TOTAL 460 DATE 6/23/2017 6/25/2017 6/25/2017 6/25/2017 0835-0955 0822-0945 0822-0945 6/25/2017 TOTAL AE DESCRIPTION OF IN 2,560 See attachments 402 53 270 3,285 ACTION TAKEN TO ELIMINATE See attachments 6/22/2017 0452-0457 60 See attachments See attachments 6/24/2017 0315-0321 70 6/25/2017 2044-2047 20 6/26/2017 2051-2059 90 TOTAL 240 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 6/3/2017 2100-2400 625 See attachments See attachments TOTAL 625 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME TOTAL 460 3,285 240 625 50,295 0 54,905 Page 8 7/18/2017 11:37 AM Flan; Start Data 06/01/2017 Flare End Date 06/30/2017 GC1 Flare Report Total Volume (MSCF) 4610 Report Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-193 Flare Relief 06/03/2017 9:00:00 pm 12:00:00 am 180 min No No Yes BP1\LEEJON 625 Determination Cause K-7001 SO and cool down for full function fire and gas PM Action Taken Closed fuel gas valve to K-7001 Daily Volume (MSCF) 625 17-212 Controlled Blowdown 06/22/2017 4:52:00 am 4:57:00 am 5 min No Determination Cause GLT compressor K-3300 shutdown due to isolating from east side. Action Taken depressured No Yes BP1\SPRINGG 60 17-217 Flare Relief 06/23/2017 8:35:00 am 95500 am 80 min Yes No No BPIGSPRINGG 2560 Determination Cause High gas transit line pressure caused by CCP compressor problems -SID Action Taken Flaring was permitted to continue while operations personnel attempted to restart the equipment. 17-220 Controlled Blowdown 06/24/2017 3:15:00 am 3:21:00 am 6 min No Determination Cause GLT compressor K-3200 shut down for line lifts - depressuretl Action Taken depressure done 17-224 Flare Relief 06/25/2017 8:22:00 am 9:45:00 pm 803 min Yes Determination Cause LP Flaring due to high ambient temperatures. Action Taken Ambient cooled down. 17-224 Other 06/25/2017 8:22:00 am 9:45:00 pm 803 min Yes Determination Cause LP Flaring Action Taken Stopped Flaring Generated 07/06/2017 2:44:22PM No Yes BP1lSPRINGG 70 Daily Volume (MSCF) 70 No No BPIUONESCC 402 No No BPIUONESCC 53 Page 8 of 10 Flare Start Date 06/01/2017 Flare End Date 06/30/2017 17-224 Flare Relief 06/25/2017 5:24:00 pm 10:42:00 pm 318 min Yes Determination Cause Spurious Stop Production Shutdown Action Taken Flow into plant isolated. 17-224 Controlled Slowdown 06/25/2017 8:44:00 pm 8:47:00 pm 3 min No Determination Cause Swapped T -bank HP ->LP -depressured Action Taken depressum complete 17-229 Controlled Blowdown 06/26/2017 8:51:00 pm 8:59:00 pm 8 min No Determination Cause Depressured GLT suction header - prep valves for TAR Action Taken depressure done Generated 07/06/2017 2:44:22PM No No BPIWONESCC 270 No Yes SP1\SPRINGG 20 Daily Volume (MSCF) 745 No Yes BPI\SPRINGG 90 Daily Volume (MSCF) 90 Total Volume (MSCF) 4610 Page 9 of 10 Link, Liz M (DOA) From: Blake, Jennifer J <Jennifer.Blake@bp.com> Sent: Wednesday, June 14, 2017 10:58 AM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Dean, James A; Borton, Kim; AK, HSSEE Env Adv West, AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Event at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting (a alaska.gov Victoria. loepp(d,)alaska.goy From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 06/03/2017 21:00 and stopping at 06/04/2017 with a volume of 625 (MSCF). The event lasted for 180 minutes and was due to spin cooling LPS compressor K-7001 for full function fire and gas PM. The flaring event stopped when the spin cooling was complete. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blake@bp.com Link, Liz M (DOA) From: Blake, Jennifer J <Jennifer.Blake@bp.com> Sent: Monday, July 3, 2017 10:44 AM To: AKOpsProdEOCTL; AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Starck, Jennifer L; Barton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting(a)alaska.gov Victoria. loeppanslaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 06/23/2017 08:35 and stopping at 06/23/2017 09:55 with a volume of 2560 (MSCF). The intermittent event lasted for 80 minutes and was due to high gas transit pressure caused by a CCP compressor trip. The flaring event stopped when the CCP compressor was reloaded and gas transit pressure was lowered. A flaring event occurred at GC1 starting at 06/25/2017 08:22 and stopping at 06/25/2017 21:45 with a volume of 402 (MSCF). The intermittent event lasted for 803 minutes and was due to LP flaring caused by high ambient temperatures. The flaring event stopped when ambient temperatures cooled down. A flaring event occurred at GC1 starting at 06/25/2017 08:22 and stopping at 06/25/2017 21:45 with a volume of 53 (MSCF). The intermittent event lasted for 803 minutes and was due to flaring LP assist gas. The flaring event stopped when the LP gas flaring event stopped. A flaring event occurred at GC1 starting at 06/25/2017 17:24 and stopping at 06/25/2017 22:42 with a volume of 270 (MSCF). The intermittent event lasted for 318 minutes and was due to a spurious Stop Production shutdown. The flaring event stopped when flow into the plant ceased (was isolated). A flaring event occurred at GCI starting at 07/03/2017 21:46 and stopping at 07/03/2017 23:59 with a volume of 22 (MSCF). The intermittent event lasted for 133 minutes and was due to low gas rates to the LP compressor, causing flaring off of Vessel V-1 20A. The flaring event stopped gas rates through the plant were increased. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blake@bp.com STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITInN 1. Facility Number 0290000031 2. Facility Name PBU GC 1 3. Field PBU - WOA 4. Operator . BP 5. MonthtYear of Disposition I July -2017 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total volume. 6. Sold O Pool Name Pool Code Percent 7. Reinjected PRUDHOE 640150 98.25% LISBURNE 640144 0.33% 8. Flared or vented 1 hour or less 0 MIDNIGHT SUN 640158 0.05% PTMCINTYRE 640180 1.37% 9. Flared or vented more than 1 hour (see instr.) 29,504 10. Pilot and Purge 35,178 11. Assist Gas 0 12. Fuel gas used in lease operations. 341,311 13. Other (see instructions) O Official Use Only Authorization >1 hr: Safety �ys�� MCF 1/7— 74. TOTAL VOLUME (ITEMS 8-12) 405,993 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: 014, fl—4 —17 Commissioner Date 18. Transferred to: (Express as a negative #) CGF -26,520,495 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. n ( A11h1P Note: All volumes must be corrected Signature Title Manager Production Taxes and Ro aloes Alaska to pressure of 14.65 psia and to a ' temperature of 60o F. Authority 20 Printed Name Diane Colle Phone (907) 564-5775 Date 114AAC25.235, 7-//-7%- Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate SP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT July 2017 TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE Not required for unplanned events <= 1 hr TOTAL 0 Not required for unplanned events <= 1 hr Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/3/2017 0001-1819 559 See attachments See attachments 7/3/2017 2146-2359 22 7/7/2017 1624-1726 14,583 TOTAL 15,164 DESCRIPTION OF IN See attachments See attachments TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/13-14/2017 0000-2359 14,340 See attachments See attachments TOTAL 14,340 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events> 1 Hour 15,164 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 14,340 exceeding 5,000 MCF Pilot Purge 35,178 Assist 0 TOTAL FLARED VOLUME 64,682 Page 10 8/13/2017 3:49 PM Flare Start Date 07/01/2017 Flare End Date 07/31/2017 GCI Flare Report Total Volume (MSCF) 29504 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-243 Controlled Blowdown 07/03/2017 12:01:00 am 6:19:00 pm 1098 min Yes No No BPI\SHELTI 559 Determination Cause LP compressor doesn't have enough gas rate to keep forr✓ard Flow and keeps recycling, causing V -120A to pressure up and relief to flare Action Taken Rates are being brought back into the plant from PM2 17-243 Controlled Blowdown 07/03/2017 9:46:00 pm 11:59:00 pm 133 min Yes No No BP1\SHELTI 22 Determination Cause LP compressor doesn't have enough gas rate to keep fonvard bow and keeps recycling, causing V -120A to pressure up and relief to Flare Action Taken Called PCC and discussed bringing more gas rate in. PM2 rates are being brought back up. Daily Volume (MSCF) 581 17-253 Flare Relief 07/07/2017 4:24:00 pm 5:26:00 pm 62 min No No No BP1\SHELTI 14583 Determination Cause High gas transit line pressurecaused by CGF compressor problems Action Taken PCC reduced production rates and shut-in wells to stop flaring Daily Volume (MSCF) 14583 17-299 Flare Relief 07/13/2017 12:00:00 am 11:59:00 pm 1439 min Yes No Yes BP7\FISHERCD 2720 Determination Cause TAR Prep Action Taken None Daily Volume (MSCF) 2720 17-265 Flare Relief 07/14/2017 12:00:00 am 11:59:00 pm 1439 min Yes No Yes BP1XIRSCHW 11620 Determination Cause tarblowdown Action Taken none planned Daily Volume (MSCF) 11620 Total Volume (MSCF) 29504 Generated 08/15/2017 1:28:23PM Page 14 of 15 Link, Liz M (DOA) From: Blake, Jennifer 1 <Jennifer.Blake@bp.com> Sent: Monday, July 3, 2017 10:44 AM To: AKOpsProdEOCTL; AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A, Arthur, Gregory; Starck, Jennifer L; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting(g alaska.gov Victoria. IoeppCcDalaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 06/23/2017 08:35 and stopping at 06/23/2017 09:55 with a volume of 2560 (MSCF). The intermittent event lasted for 80 minutes and was due to high gas transit pressure caused by a CCP compressor trip. The flaring event stopped when the CCP compressor was reloaded and gas transit pressure was lowered. A flaring event occurred at GC1 starting at 06/25/2017 08:22 and stopping at 06/25/2017 21:45 with a volume of 402 (MSCF). The intermittent event lasted for 803 minutes and was due to LP flaring caused by high ambient temperatures. The flaring event stopped when ambient temperatures cooled down. A flaring event occurred at GC1 starting at 06/25/2017 08:22 and stopping at 06/25/2017 21:45 with a volume of 53 (MSCF). The intermittent event lasted for 803 minutes and was due to flaring LP assist gas. The flaring event stopped when the LP gas flaring event stopped. A flaring event occurred at GC1 starting at 06/25/2017 17:24 and stopping at 06/25/2017 22:42 with a volume of 270 (MSCF). The intermittent event lasted for 318 minutes and was due to a spurious Stop Production shutdown. The flaring event stopped when flow into the plant ceased (was isolated). A flaring event occurred at GC1 starting at 07/03/2017 21:46 and stopping at 07/03/2017 23:59 with a volume of 22 (MSCF). The intermittent event lasted for 133 minutes and was due to low gas rates to the LP compressor, causing flaring off of Vessel V-1 20A. The flaring event stopped gas rates through the plant were increased. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 lennifer.blake@bp.com Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Friday, August 25, 2017 1:55 PM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Starck, Jennifer L; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting(a)alaska.gov Victoria. Ioepp(o)alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GC1 starting at 07/03/2017 00:01 and stopping at 07/03/2017 18:19 with a volume of 559 (MSCF). The intermittent event lasted for 1098 minutes and was due to low gas rates to the LP compressor, causing flaring off of Vessel V -120A. The flaring event stopped when gas rates through the plant were increased. A flaring event occurred at GC1 starting at 07/03/2017 21:46 and stopping at 07/03/2017 23:59 with a volume of 22 (MSCF). The intermittent event lasted for 133 minutes and was due to low gas rates to the LP compressor, causing flaring off of Vessel V-1 20A. The flaring event stopped when gas rates through the plant were increased. A flaring event occurred at GC1 starting at 07/07/2017 16:24 and stopping at 07/07/2017 17:26 with a volume of 14583 (MSCF). The event lasted for 62 minutes and was due to high transit gas line pressure caused by CGF compressor problems. The flaring event stopped when rates were reduced. A flaring event occurred at GC1 starting at 07/13/2017 00:00 and stopping at 07/13/2017 23:59 with a volume of 2720 (MSCF). The event lasted for 1439 minutes and was due to preparations for the upcoming Turn Around (TAR) . The flaring event stopped when preparation activities were completed. A flaring event occurred at GC1 starting at 07/14/2017 00:00 and stopping at 07/14/2017 23:59 with a volume of 11620 (MSCF). The event lasted for 1439 minutes and was due to blowing down the facility for TAR . The flaring event stopped when the blowdown was completed. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell(907)830-6204 Jennifer. blake@bp.com STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number2. 0290000031 Facility Name PBU GC 1 3. Field PBU - WOA 4. Operator BP 5. Month/Year of Disposition August -2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Q Pool Name PoolCode Percent 7. Reinjected O PRUDHOE 640150 98.42% LISBURNE 640144 0.34% 8. Flared or vented 1 hour or less 1,638 MIDNIGHT SUN 640158 0.08% PT MCINTYRE 640180 1,16% 9. Flared or vented more than 1 hour (see instr.) 50,779 10. Pilot and Purge 34,547 11. Assist Gas U 12. Fuel gas used in lease operations. 493,398 13. Other (see instructions) 0 Official Use Only Authorization>1 hr: Safety G MCF lr7Z 14. TOTAL VOLUME (ITEMS 6-12) 580,362 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner Date 18. Transferred to: (Express as a negative #) CGF -32,655,350 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. LNote: All volumes must be corrected Signature_ Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a / temperature of 60o F. Authority 20 Printed Name Diane Colleyate Phone (907) 564-5775 D Form 10422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate UATE TIME 8/25/2017 1537-1634 8/26/2017 1727-1752 ACTION TAKEN TO ELIMINATE CAUSE 8/27/2017 1530-1603 See attachments 8/30/2017 0345-0411 Planned events greater than 1 hour TOTAL BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT -GC -1 GAS FLARING INCIDENT REPORT August 2017 IE DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 800 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 208 240 380 1,628 DESCRIPTION OF INCIDENT See attachments ACTION TAKEN TO E See attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 8/10/2017 1821-1822 10 See attachments See attachments TOTAL 10 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 8/12-17/17 0729-2359 50,779 See attachments See attachments TOTAL 50,779 TOTAL Unplanned Events < 1 Hour 1,628 Unplanned Events> 1 Hour 0 Planned Events < 1 hour and not 10 exceeding 5,000 MCF Planned Events > 1 hour or 50,779 exceeding 5,000 MCF Pilot Purge 34,547 Assist 0 TOTAL FLARED VOLUME 86,964 Page 7 9/14/2017 4:31 PM Flare Start Date 08/01/2017 Flare End Date 08/31/2017 GC1 Flare Report Total Volume (MSCF) 52417 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-321 Flare Relief 08/10/2017 6:21:00 pm 6:22:00 pm 1 min No No Yes BP1 VONESCC 10 Determination Cause Depressured K-3320. Action Taken K-3320 depressured. Daily Volume (MSCF) 10 17-323 Flare Relief 08/12/2017 7:29:00 am 11:59:00 pm 990 min Yes No Yes BPIUONESCC 6920 Determination Cause Post TARwarm-up. Action Taken none Daily Volume (MSCF) 6920 17-349 Flare Relief 08/13/2017 12:01:00 am 11:59:00 pm 1438 min Yes No Yes BPITISHERCD 4680 Determination Cause Start-up after TAR Action Taken none Daily Volume (MSCF) 4680 17-327 Flare Relief 08/14/2017 12:00:00 am 11:59:00 pm 1439 min Yes No Yes 3P1\KIRSCHW 26000 Determination Cause tar Action Taken tar Daily Volume (MSCF) 26000 17-331 Flare Relief 08/15/2017 12:00:00 am 11:59:00 pm 1439 min Yes No Yes BPIIKIRSCHW 11600 Determination Cause start-up Action Taken planned start-up Daily Volume (MSCF) 11600 17-348 Flare Relief 08/16/2017 12:01:00am M59:00pm 1438 min Yes No Yes BPt\FISHERCD 790 Determination Cause Start-up activities after TAR Action Taken none Daily Volume (MSCF) 790 17-335 Flare Relief 08/17/2017 12:00:00 am 11:59:00 pm 1439 min Yes Yes Yes BPIIKIRSCHW 789 Determination Cause start-up Action Taken none start-up Generated 09/06/2017 4:06:25PM Daily Volume (MSCF) 789 Page 8 of 11 Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Thursday, September 14, 2017 9:30 AM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Starck, Jennifer L; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc reporting@alaska.gov Victoria. loepp(a alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GCI starting at 08/12/2017 07:29 and continuing on to the next day with a volume of 6920 (MSCF) on 08/12/2017. The event lasted for 990 minutes and was due to post TAR warm-up. The flaring even continued into 08/13/2017. A flaring event occurred at GCI continuing from the previous day, 08/12/2017, and continuing on into the next day 08/14/2017. Starting at 00:00 08/13/2017 and stopping at 23:59 08/13/2017 the volume for the day was 4680 (MSCF). The event lasted for 1439 minutes and was due to Start-up after TAR. The flaring event continued into the next day. A flaring event occurred at GCI continuing from the previous day, 08/13/2017, and carrying on to the following day. The volume for 08/14/2017 was 26000 (MSCF). The event lasted for 1439 minutes on 08/14/2017 and was due to re -pressurization and post TAR startup. The flaring event continued into the next day. A flaring event occurred at GCI continuing from the previous day, 08/14/2017, and carrying on to the following day. The volume for 08/15/2017 was 11600 (MSCF). The event lasted for 1439 minutes on 08/15/2017 and was due to post TAR startup. The flaring event continued into the next day. A flaring event occurred at GCI continuing from the previous day, 08/15/2017, and carrying on to the following day. The volume for 08/16/2017 was 790 (MSCF). The event lasted for 1439 minutes on 08/16/2017 and was due to post TAR startup. The flaring event continued into the next day. A flaring event occurred at GCI continuing from the previous day, 08/16/2017, and stopping at 08/17/2017 23:59 with a volume of 789 (MSCF). The event lasted for 1439 minutes and was due to post TAR startup. The flaring event stopped when post TAR startup activities were completed Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell(907)830-6204 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000031 2. Facility Name PBU GC 1 3. Field PBU - WOA 4. Operator BP 5. Month/Year of Disposition I Se tember-2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name PoolCode Percent 7. Reinjected O PRUDHOE 640150 96.997/6 LISBURNE 640144 0.37% 8. Flared or vented 1 hour or less 140 MIDNIGHT SUN 640158 0.09% PT MCINTYRE 640180 2.55% 9. Flared or vented more than 1 hour (see instr.) 699,139 10. Pilot and Purge 53,529 11. Assist Gas 0 12. Fuel gas used in lease operations. 676,091 13. Other (see instructions) 0 Official Use Only Authorization >1 hr �( Safety 6qa r3s MCF 14. TOTAL VOLUME (ITEMS 6-12) 1,428,899 Lease use MCF 15. NGL Gas Equivalent O Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: 0 P 3-1�-1'8 Commissioner Date 18. Transferred to: (Express as a negative # CGF ( p 9 ) -52,633,276 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. ,(% l///'''��I9lrL�,n�' Note: All volumes must be corrected Signature 'rV �-t c� Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psis and to a //11 temperature of 60o F. Authority 20 Printed Name Diane ColleyPhone (907) 564-5775 Data r/ Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate DATE 9/20/2017 9/6-13/17 9/13/2017 9/29/2017 9/3/2017 9/4/2017 DATE BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT September 2017 TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1315-1316 10 Not required for unplanned events <= 1 hr TOTAL 10 TIME 2043-2359 0520-2305 0911-1015 TOTAL 1943-1948 2043-2054 TOTAL TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 698,419 See attachments 660 60 699,139 70 See attachments 60 130 U TOTAL 10 699,139 130 0 53,529 0 752,808 DESCRIPTION OF INCIDENT See attachments Not required for unplanned events <= 1 hr See attachments See attachments See attachments Page 6 10/12/2017 2:33 PM Flare StartDate 09/01/2017 Flare End Date 09/30/2017 GC1 Flare Report Total Volume (MSCF) 699279 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-352 Flare Relief 09/03/2017 7:43:00 pm 7:48:00 pm 5 min No Determination Cause Startup K-7000 after water wash Action Taken Flaring stopped once compressor was online 17-353 Flare Relief 09/04/2017 8:43:00 pm 8:54:00 pm 11 min No Determination Cause Startup K-7001 after water wash Action Taken Flaring stopped once compressor was online 17-355 Flare Relief 09/06/2017 8:43:00 on 11:59:00 pm 196 min Yes Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaiting pans No Yes BP7\SHELT1 70 Daily Volume (MSCF) 70 No Yes BP1\SHELTI 60 Daily Volume (MSCF) 60 No No BP11SPRINGG 3760 Daily Volume (MSCF) 3760 17-356 Flare Relief 09/07/2017 12:00:00 am 12:00:00 am 1440 min Yes No No BP1 ZPRINGG 87150 Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaiting parts Daily Volume (MSCF) 87150 17-357 Flare Relief 09/08/2017 12:00:00 am 12:00:00 am 1440 min Yes No No BPIISPRINGG 172630 Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaiting parts 17-359 Flare Relief 09/09/2017 12:00:00 am 12:00:00 am 1440 min Yes Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaking parts Daily Volume (MSCF) 172630 No No 3P1\SPRINGG 181530 17-360 Flare Relief 09/10/2017 1200:00 am 12:00:00 am 1440 min Yes No Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaiting parts 17-362 Flare Relief 09/11/2017 12:00:00 am 12:00:00 am 1440 min Yes Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaiting parts Daily Volume (MSCF) 181530 No BP1\SPRINGG 116110 Daily Volume (MSCF) 116110 No No BP1\SPRINGG 86750 17-363 Flare Relief 09/12/2017 1200:00 am 3:30:00 pm 930 min Yes No Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaiting parts Daily Volume (MSCF) 86750 No BP1\SPRINGG 48010 Daily Volume (MSCF) 48010 17-365 Flare Relief 09/13/2017 12:00:00 am 11:59:00 pm 1439 min Yes Yes No BP1 WRINGG 2479 Determination Cause fouled TEG system causes condensate laden assist gas leading to black smoke events Action Taken repairing reboilers , lowered rates 17-365 Flare Relief 09/13/2017 5:20:00 am 11:05:00 pm 1065 min Yes No No BP1\SPRINGG 660 Generated 10/02/2017 2:13:02PM Page 4 of 8 Flare Start Date 09/01/2017 Flare End Date 09/30/2017 Determination Cause Fouled Odd/Even TEG regeneration system Action Taken None at this time -awaiting parts Daily Volume (MSCF) 3139 17-388 Flare Relief 09/29/2017 9:11:OOam 10:15:00am 84min No No No 8P7\SHELTI 80 Generated 10/02/2017 2:13:02PM Page 5 of 8 Flare Start Date 09/01/2017 Flare End Date 09/30/2017 Determination Cause Flared off V-136, due to K-108 going down on a high temp on the gas/gas exchanger Action Taken The other gas/gas exchanger was opened up to lower gas temperature, allowing K-108 to be put back online and stop nanng off V-136 Daily Volume (MSCF) 60 Total Volume (MSCF) 699279 Generated 10/02/2017 2:13:02PM Page 6 of 8 Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Wednesday, October 11, 2017 1:56 PM To: AOGCC Reporting (DOA sponsored) Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Starck, Jennifer L; Borton, Kim; Cc: AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; AK, HSSEE Env Adv West; Buckbee, Rachel A Subject: Flaring Events at GC1 Follow Up Flag: Follow up Flag Status: Flagged To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aoqcc.rel)orting@alaska.gov Victoria Ioepp(d)alaskagov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GCI starting at 09/06/2017 20:43 and continuing to 09/13/2017. Daily volumes and durations are summarized below. The event was due to fouling of the Odd and Even TEG regeneration systems. The event continued while the Operations and Maintenance teams were troubleshooting interim mitigations to the fouling while waiting for permanent repair parts. The flaring event stopped on 09/13/2017 when the odd reboiler fouling was cleared and throughput was kept at reduced rates while the even reboiler was waiting parts for permanent repair. • 09/06/2017: volume of 3760 (MSCF). Duration of 196 minutes. Start time 20:43 and continues through 09/12/2017 • 09/07/2017: volume of 87150 (MSCF). Du• ration of 1440 minutes. 09/08/2017: volume of 172630 (MSCF). Duration of 1440 minutes. • 09/09/2017: volume of 181530 (MSCF). Duration of 1440 minutes. 09/10/2017: volume of 116110 (MSCF). Duration of 1440 minutes. • 09/11/2017: volume of 86750 (MSCF). Duration of 1440 minutes. • 09/12/2017: volume of 48010 (MSCF). Duration of 930 minutes. Start time 00:00, stop time 15:30. • 09/13/2017: volume of 2479 (MSCF). The event lasted for 1440 minutes. The event started at 00:00 and ended at 23:59. A flaring event occurred at GCI starting at 09/29/2017 09:11 and stopping at 09/29/2017 10:15 with a volume of 60 (MSCF). The event lasted for 64 minutes and was due to the HP Compressor, K-108, tripping offline due to high temp on the gas/gas exchanger. The flaring event stopped when the second gas/gas exchanger was opened up to lower gas temperatures allowing K-108 to be restarted. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRMI IrFn me n1cDnQ1T1nK1 1. Facility Number 2. Facility Name 0290000031 PBU GC 1 Disposition 3. Field PBU - WOA Volume MCF WW ... Wils 4. Operator 5. MonthNear of Disposition BP October -2017 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Code Percent 7. Reinjected O 640150 97.10% 640144 0.28 % 8. Flared or vented l hour or less 6,499 WMIDNIGHTSUN640158 0.11% 640180 2.51% 9. Flared or vented more than 1 hour (see instr.) 4,280 10. Pilot and Purge 58,403 11. Assist Gas 0 12. Fuel gas used in lease operations. 736,970 13. Other (see instructions) Official Use Only Authorization 11 hr: P/0 Safety u 1� f MCF 14. TOTAL VOLUME (ITEMS 6-12) 806,152� Lease Use MCF MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: 0 Commissioner 7 Date 18. Transferred to: (Express as a negative #) CGF 4L:6:5.169,166 19, Remarks: I hereby cattily that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a Printed Name Diane Colley- temperature of 60o F. Authority 20 Phone (907) 564-5775 Date AAC25 2 Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate wor q mj ale lq•jaI!uuaf bOZ9-0£S (L06) IIaJ 9Z6S-b9S (L06) a:)IHO peal weal uo!lez!w!ldo uo!lonpoad 003 ar1e iaf!uuar `sTMq.L 'Ino sem uoilonpoid uagm paddols Juana 8ui.zeU 3141 'pie3 D -Id e ql[m paJetoosse malgozd a 3o asne0aq umop Outlings OOOL-N .lossaldmoD Sd7 of anp sem pue salnuim 06 IQJ palsel Juana aql '(JDSW) 000V 30 amnion e grim 0£ bi LIOZ/6Z/OI ie $utddols pue 00 £i LIOZ/6Z/OI le OUTLleIS 100 It paim000 Juana 8utieli d 'Ino sem umimpozd uogm paddols Iuana aq1 'amssa.id auil IisueiJ g2ig SuiltIon auill3o guiddiii `ZO8I `iossaadwoo .talsooq s, jgo of anp sem puu (dDSW) 0005 uegl jaiewO 3uml0n e peq Juana 3ql '(JDSW) 66b930 auznion e Pm Ob:00 L I OZ/£Z/O I it, 8uiddols pue 0000 L I OZ/£Z/0l It Outuels 109 it p3zzn00o Iuana 2UIJBO V 'pasea.loap amssawd auil J[sueal uagm paddols Juana 8utIeli aq1 'Jualltuzzalui sem Juana 8uiaeg agl aznssazd auil JisuezI g3iq of anp sem put solnuim b££ JOJ palsel Juana aql '(IDSW) 08Z 30 auznlon e glim LZ:9I LIOZ/ZI/OI ie 8uiddols pue £5:60 LIOZ/ZI/OI it Sufueis log ie pazin00o Juana $utzed V npeaZ meal uoilezimildo uotlonpozd gag `axelg ia31uuaf :moz3 A0b e>Isele ao1'euol0in no 'e>IseJe u!lao ar00 oV 00J0V'ddaoj euolo!n :00 6u!laodaa OOJOV Ol LDJ le sluan3 6uue13 :hafgns V la40ed'aagjOne :u!goa 'Janolg'WSO L09 SdO ')IV 'll0 41!1!Oed L D9 SdO ')IV 'lsaM APV ^u3 33SSH 'SIV :w!N 'uolJoa :3 JaI!uuaf'j:)jelS'tio6ajg 'anglJV :V ijeO'uosu98'(VOO) 1 eu0l0!A'ddao-1 (paaosuods Vo(]) 6u!liodaa »JOV :ol WV 90:8 LLOZ'LE aagol00'Aepsanl :luas <wo0'dgpn 310030JdSdO)IV> 11003poadsdo)IV :woz j Woo) W ziq ')lull BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT October 2017 Unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 10/23/2017 0000-0040 6,499 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr TOTAL 6,499 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 10/12/2017 0953-1527 280 See attachments See attachments 10/29/2017 1300-1430 4,000 TOTAL 4,280 events less than or equal to 1 hour I IML VOLUME DESCRIPTION OF IN See attachments TOTAL 0 TIME VOLUME DESCRIPTION OF INCIDENT & See attachments TOTAL 0 ACTION TAKEN TO ELIMINATE See attachments See attachments CAUSE Page 7 11/13/2017 9:27 AM TOTAL Unplanned Events < 1 Hour 6,499 Unplanned Events > 1 Hour 4,280 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 58,403 Assist 0 TOTAL FLARED VOLUME 69,182 ACTION TAKEN TO ELIMINATE See attachments See attachments CAUSE Page 7 11/13/2017 9:27 AM Flare Start Date 10/0112017 Flare End Date 10/3112017 GCI Flare Report Total Volume (MSCF) 10779 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-393 Flare Relief 10/12/2017 9:53:00 am 3:27:00 pm 334 min Yes No No 8PI6SPRMGG 280 Determination Cause High gastransit line pressure Action Taken No response taken as this was deemed to be of short duration Daily Volume (MSCF) 280 17417 Flare Relief 10/29/2017 1:00:00 pm 2:30:00 pm 90 min No No No BPIIDELATI 4000 Determination CaUSe LPS compressor K-7000 shut down because of a problem associated with PLC card Action Taken WOA reduced production rates and shut-in 7 wells equaling e5mmscfd. Wells were shut-in or choked back starting at 13:00houm. Daily Volume (MSCF) 4000 Total Volume (MSCF) 10779 Generated 11/03/2017 1:17:48PM Page 7 of 8 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000031 2 Facility Name PIB GC 1 3. Field PBU - WOA 4. Operator BP 5. Monlh/Year of Disposition November -2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected U PRUDHOE 640150 97.28% LISBURNE 640144 0.28% 8. Flared or vented l hour or less 293 MIDNIGHTSUN 640158 0.09% PT MCINTYRE 640180 2.35% 9. Flared or vented more than 1 hour (see instr.) 10 10. Pilot and Purge 54,787 11. Assist Gas 0 12. Fuel gas used in lease operations. 876,764 13. Other (see instructions) 0 Official Use Only Au Authorization hr 's a Safety MCF 14. TOTAL VOLUME (ITEMS 6.12) 931,854 Lease Use 10 MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 Commissioner[—µ— !Date 18. Transferred to: (Express as a negative #) CGF -63,200,411 19. Remarks: I hereby certify that thg foregoing is truecorrect to the best of my knowledge. /v( )lJ Note: All volumes must be corrected Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 Asia and to a Printed Name Diane Colley Phone (907) 584-5775 Date /W -7 temperature of 60o F. Authority 20 AAC25 235 Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -1 GAS FLARING INCIDENT REPORT November 2017 unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 11/2/2017 0653-0705 1 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 11/20/2017 1626-1636 42 TOTAL 43 See attachments See attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 11/3/2017 1950-2015 250 See attachments See attachments TOTAL 250 11/6/2017 1940-2400 TOTAL Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour and not exceeding 5,000 NICE Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME FLUME DESCRIPTION OF IN 10 See attachments 10 TOTAL 43 0 250 10 54,787 0 55,090 ACTION TAKEN TO I See attachments Page 6 12/13/2017 9:07 AM Flare Start Date 11/01/2017 Flare End Date 11/30/2017 GC1 Flare Report Total Volume (MSCF) 3C3 Report Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 17-419 Other 11/03/2017 7:50.00 pm 8:15:00 pm 25 min No Determination Cause Start-up GTRB-51-3220 Action Taken Sustained ignition. 17-421 Flare Relief 11/06/2017 7:40:00 pm 12:00:00 am 260 min Yes Determination Cause SwappedlPcompressomforPMwork Action Taken none No Yes BPIWONESCC 250 No Daily Volume (MSCF) 250 Daily Volume (MSCF) 10 Total Volume (MSCF) 303 Generated 12/06/2017 9:22:30AM Page 5 of 6 Link, Liz M (DOA) From: AKOpsProdEOCTL <AKOPSPCCEOCTL@bp.com> Sent: Monday, December 18, 2017 3:59 PM To: AOGCC Reporting (DOA sponsored) Cc: Loepp, Victoria T (DOA); Benson, Gary A; Arthur, Gregory; Starck, Jennifer L; Borton, Kim; AK, HSSEE Env Adv West; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; Glover, Robin; Buckbee, Rachel A Subject: Flaring Events at GC1 To: AOGCC Reporting CC: Victoria Loepp, AOGCC Aogcc.reporting (c)alaska.gov Victoria. loepp(o)alaska.gov From: Jennifer Blake, GPB Production Optimization Team Leader A flaring event occurred at GCI starting at 11/06/2017 19:40 and stopping at 11/07/2017 24:00 with a volume of 10 (MSCF). The event lasted for 260 minutes and was due to swapping IP compressors for PM work. The flaring event was intermittent. The flaring event stopped when the swap was completed. Thanks, Jennifer Blake EOC Production Optimization Team Lead Office (907) 564-5926 Cell (907) 830-6204 Jennifer.blake@bp.com STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FAMI ITV RDDnDT nr nmr%r%i Form 10-422 Rev, 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT- GC -1 GAS FLARING AND VENTING INCIDENT REPORT December 2017 ---u avcrnts less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CA75E 12/26/2017 0930-1007 210 Not required for events <= 1 hr TOTAL 210 Wt�LKIPTION OF INCIDENT & CAUSE 12/7-10/2017 2230-1440 1,825 "Cold Venting" when 42" flare line lost flame 12/14/2017 1225-2325 1,406 "Cold Venting" when 42" flare line lost flame TOTAL 3,231 12/3/2017 2216.2236 Ut INLIDENT & CAUSE 12/30/2017 750 Not required for events <= 1 hr 1950-1955 30 TOTAL 780 Hoed events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL 0 Unplanned Events < 1 Hour TOTAL 210 Unplanned Events > 1 Hour 3,231 Planned Events < 1 hour and not exceeding 5,000 MCF 780 Planned Events > 1 hour or exceeding 5,000 MCF 0 Pilot Purge 778,811 Assist 0 TOTAL FLARED VOLUME 783,032 Not required for events <= 1 hr Attempting to re -light flare and establish flame Attempting to re -light flare and establish flame Not required for events <= 1 hr See attachments Page 7 1/12/2018 9:58 AM