Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutKuparuk River CPF 3 - ConocoPhillips Alaska, IncSTATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
January 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
52904
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
30701
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
21004
11. Assist Gas
100.00%
12. Fuel gas used in lease operations
556147
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
660756
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
920448
Waste:
MCF
18. Transferred to: (Express as a negative #)
-671628
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is Oooguruk sales 0 Nikaitchuq sales 52,217, and Air Force Power generation sale 687. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature 7� 7404ff" Title Analyst, Production & Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10422 Rev. 5/2009
VOLUME
DATE TIME MSCF
1/31/2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
January-2019
PLANNED
ACTION TAKEN TO MINIMIZE
DESCRIPTION OF FLARING EVENT UNPLANNED VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
0
TOTAL OVER 1 HOUR
Planned > 1 Hour
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greater than 1 hour
0
Less than 1 hour
30,701
Continuous Assist
0
Pilot and Purge
21,004
TOTAL FLARED/VENTED 51,705
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
February 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
50024
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
10846
9. Flared or vented more than 1 hour (see instr.)
620
10. Pilot and Purge
18573
11. Assist Gas
100.00
12. Fuel gas used in lease operations
518107
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
598170
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MMCF
MCF
17. Transferred from:
793506
Waste:
18. Transferred to: (Express as a negative #)
-598119
—I/ g 1
14— Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is oguruk sales 0 Nikaitchuq sales 49,372, and Air Force Power generation sale 652. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature /� Title Analyst, Production 8 Revenue Accounting NOTE: Al volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
2/28/2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
February-2019
PLANNED
VOLUME ACTION TAKEN TO MINIMIZE
DATE TIME MSCF DESCRIPTION OF FLARING EVENT UNPLANNED VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
The ambient rose sustantially as well as the
12:46:00 PM - tie line pressure and prevented getting off
2/27/2019 02:32:00 PM 620 the flare.
TOTAL OVER 1 HOUR 620
Planned > 1 Hour
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greaterthan 1 hour
620
Less than 1 hour
10,846
Continuous Assist
0
Pilot and Purge
18,573
TOTAL FLARED/VENTED 30,039
N Reduced/increased inlet gas rates.
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. MonthNear of Disposition
March 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
58624
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
7039
9. Flared or vented more than 1 hour (see instr.)
687
10. Pilot and Purge
20577
11. Assist Gas
100.00
12. Fuel gas used in lease operations
609653
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
696580
Authorization >1 hr Of
Safety
MCF
15. NGL Gas Equivalent
0
l�
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
792314
Waste:
MCF
18. Transferred to: (Express as a negative #)
-621006
pI
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is OoodVuk sales 0 Nikaitchuq sales 58,043, and Air Force Power generation sale 581. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature 7SP746"W Title Analyst, Production & Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev.5/2009
3/31 /2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
March-2019
PLANNED
VOLUME
DATE TIME MSCF DESCRIPTION OF FLARING EVENT UNPLANNED
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
07:03:00 PM - High ambient temperatures caused FLC
3/24/2019 08:15:00 PM 687 inefficiencies IGOR was cut to compensate
TOTAL OVER 1 HOUR 687
Planned > 1 Hour 0
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greaterthan 1 hour 687
Less than 1 hour 7,039
Continuous Assist 0
Pilot and Purge 20,577
TOTAL FLARED/VENTED 28,303
ACTION TAKEN TO MINIMIZE
VOLUME
N changed inlet gas rates.
-ECEI"VED
JUN 07 2019
STATE OF ALASKA �����
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. MonthNear of Disposition
April2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
59226
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
6332
9. Flared or vented more than 1 hour (see instr.)
163
10. Pilot and Purge
21174
11. Assist Gas
100.00
12. Fuel gas used in lease operations
562688
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
649583
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
628432
Waste:
MCF
18. Transferred to: (Express as a negative #)
-520147
l
Commissioner Dale
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 i ooguruk sales 1,547 Nikaitchuq sales 57,148, and Air Force Power generation sale 531. Line 18 is Oooguruk returned gas
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature /� Title Analyst, Production 8 Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
May 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
57697
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
6027
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
26128
11. Assist Gas
100.00
12. Fuel gas used in lease operations
498889
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
587741
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
861321
Waste:
MCF
18. Transferred to: (Express as a negative #)
-602450
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is Oooguruk sales 0 Nikaitchuq sales 57,176, and Air Force Power generation sale 521. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature /� Title Analyst, Production R Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
5/31 /2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
May-2019
DATE TIME
VOLUME
MSCF
DESCRIPTION OF FLARING EVENT
PLANNED
UNPLANNED
ACTION TAKEN TO MINIMIZE
VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
Stripping gas flow has been added to the
09:47:00 PM -
Regen system which can cause the Slop Oil
5/3/2019 10:51:00 PM
0
flare to have higher than normal flow rates.
N
Corrected inlet gas rates
Event exceeded 1 hour by 34 seconds. Due
to facility maintenance, abnormal conditions
caused us to run to the Slop Oil Tank for a
period of time. While bringing the Slop Oil
back into the process, the flare was
08:54:00 AM -
triggered just long enough to exceed by 34
Stabilized facility process and
5/6/2019 09:54:00 AM
0
seconds.
N
operation
TOTAL OVER 1 HOUR 0
Planned > 1 Hour 0
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greater than 1 hour
0
Less than 1 hour
6,027
Continuous Assist
0
Pilot and Purge
25,128
TOTAL FLARED/VENTED 31,155
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
June 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
45143
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
7653
9. Flared or vented more than 1 hour (see instr.)
3985
W. Pilot and Purge
22938
11. Assist Gas
100.00
12. Fuel gas used in lease operations
560529
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6.13)
640248
Authorization >1
Safety
$
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
721317
Waste:
MCF
18. Transferred to: (Express as a negative #)
-584352
/ y,y�� ,Z
D G
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is Ooog ryk sales 0 Nikaitchuq sales 44,590, and Air Force Power generation sale 553. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature Title Analyst, Production & Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
6/30/2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
June-2019
PLANNED
VOLUME
DATE TIME
MSCF
DESCRIPTION OF FLARING EVENT
UNPLANNED
FLARING OR VENTING EVENTS GREATER THAN 1
HOUR
The ambient temperatures were climbing
very rapidly today which caused for high
pressures in the facility. The board operator
was constantly cutting gas during the fight
against rapids rise in ambient temperatures.
01:49:00 PM -
Right in the middle of all this B-GLC tripped
6/11/2019 03:40:00 PM
1,410
offline causing the facility to flare.
N
B-GLC tripped ona high temp of the HP
compressor bearing. Higher ambient temps
01:50:00 PM -
also affected the time to recover from the
6/20/2019 03:56:00 PM
2,575
loss of the GLC
N
TOTAL OVER 1 HOUR 3,985
Planned > 1 Hour 0
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greater than 1 hour
3,985
Less than 1 hour
7,653
Continuous Assist
0
Pilot and Purge
22,938
TOTAL FLARED/VENTED 34,576
ACTION TAKEN TO MINIMIZE
VOLUME
Once the machine tripped offline, we
immediately cut the L/G rates and tried
restarting the machine two times.
Once we could not get the GLC up; we
started shutting in wells until the
system quit flaring.
Cut gas rates and shut in multiple
wells
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
July 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
41196
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
11140
9. Flared or vented more than 1 hour (see instr.)
4430
10. Pilot and Purge
21881
11. Assist Gas
100.00
12. Fuel gas used in lease operations
365618
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
444265
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
768773
Waste:
MCF
18. Transferred to: (Express as a negative #)
-538430
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 i" ooguruk sales 0 Nikaitchuq sales 40,587, and Air Force Power generation sale 609. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoingistrue and correct to the best of my knowledge
Signature / Title Analyst, Production & Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
VOLUME
DATE TIME MSCF
7/31 /2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
July-2019
PLANNED
DESCRIPTION OF FLARING EVENT UNPLANNED
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
"B" GLC shut down because of bad RTD on
HP compressor thrust journal bearing.
12:36:00 PM - Flared while trying to repair RTD and restart
7/4/2019 04:12:00 PM 4,430 machine
TOTAL OVER 1 HOUR 4,430
Planned > 1 Hour 0
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greater than 1 hour
4,430
Less than 1 hour
11,140
Continuous Assist
0
Pilot and Purge
21 8881
TOTAL FLARED/VENTED 37,451
N
ACTION TAKEN TO MINIMIZE
VOLUME
Reduced inlet gas rates and stabilized
facility process and operation
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
August 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
34838
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
B. Flared or vented 1 hour or less
3181
9. Flared or vented more than 1 hour (see instr.)
8034
10. Pilot and Purge
15783
11. Assist Gas
100.00%
12. Fuel gas used in lease operations
371784
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
433620
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
497563
Waste:
MCF
18. Transferred to: (Express as a negative #)
-390108
Z3
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is 0y6guruk sales 5,264 Nikaitchuq sales 29,024, and Air Force Power generation sale 550. Line 18 is Oooguruk returned gas
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature Title Analyst, Production & Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
8/31 /2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
August-2019
PLANNED
VOLUME ACTION TAKEN TO MINIMIZE
DATE TIME MSCF DESCRIPTION OF FLARING EVENT UNPLANNED VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
Planned 3 year ESD and PM; Plant
shutdown at CPF3. Flare event included
06:17:00 AM -
controlled shutdown and plant blowdown as
8/9/2019 07:46:00 AM
7,971 per the planned PM. Y Facility maintenance completed
Approximately 50% (50 MSCF) of total
10:50:00 AM -
volume flared (113 MSCF) was N2 from
8/17/2019 12:06:00 PM
63 purging the gas system pre -start-up. Y Facility maintenance completed
TOTAL OVER 1 HOUR 8,034
Planned > 1 Hour 8,034
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greaterthan 1 hour
8,034
Less than 1 hour
3,181
Continuous Assist
0
Pilot and Purge
15,783
TOTAL FLARED/VENTED 26,998
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
September 2019
Disposition
Volume MCF
20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
32233
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
S. Flared or vented 1 hour or less
7055
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
17241
11. Assist Gas
100.00%
12. Fuel gas used in lease operations
468323
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
524852
Authorization >t hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
91MCF
MCF
17. Transferred from:
789009
Waste:
18. Transferred to: (Express as a negative #)
-617463
r
1 Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is Oooguruk sales 0 Nikaitchuq sales 31,788, and Air Force Power generation sale 445. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature Title Analyst, Production 8 Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
9/30/2019
CONSERVATION ORDER NO.219
GAS FLARING OR VENTING INCIDENTS
CPF #3
September-2019
PLANNED
VOLUME ACTION TAKEN TO MINIMIZE
DATE TIME MSCF DESCRIPTION OF FLARING EVENT UNPLANNED VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
0
TOTAL OVER 1 HOUR
Planned > 1 Hour
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greaterthan 1 hour
0
Less than 1 hour
7,055
Continuous Assist
0
Pilot and Purge
17,241
TOTAL FLARED/VENTED 24,296
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. MonthNear of Disposition
October 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
39804
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
4344
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
18515
11. Assist Gas
100.00
12. Fuel gas used in lease operations
521413
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
584076
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
714483
Waste:
MCF
18. Transferred to: (Express as a negative #)
-531677
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is Oooguruk sales 0 Nikaitchuq sales 39,804, and Air Force Power generation sale 0. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature Title Analyst, Production & Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
November 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
45175
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
5043
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
20116
11. Assist Gas
100.00
12. Fuel gas used in lease operations
426693
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
497027
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
757775
Waste:
MCF
18. Transferred to: (Express as a negative #)
-456278
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is Oooguruk sales 0 Nikaitchuq sales 44,670, and Air Force Power generation sale 505. Line 18 is Oooguruk returned gas.
I hereby certify that the foregoing is true and correct to the best of my knowledge
Signature _S Title Anatyst, Production & Revenue Accounting NOTE: All volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
STATE OFALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000023
2. Facility Name
CENTRAL PROCESSING FACILITY #3
3. Field
Kuparuk River Unit
4 Operator
CONOCOPHILLIPS COMPANY
5. Month/Year of Disposition
December 2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of Total Volume
6. Sold
42345
Pool Name
Pool Code
Percent
7. Reinjected
0
KUPARUKRIVER UNIT
490100
100.00%
8. Flared or vented 1 hour or less
8716
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
21234
11. Assist Gas
100.00
12. Fuel gas used in lease operations
594196
13. Other (see instructions)
0
Official Use Only
14. TOTAL VOLUMES (ITEMS 6-13)
666491
Authorization >1 hr
Safety
MCF
15. NGL Gas Equivalent
0
Lease Use
MCF
16. Purchased gas
0
Conservation
MCF
17. Transferred from:
731001
Waste:
MCF
18. Transferred to: (Express as a negative #)
-570620
Commissioner Date
19. Remarks: Reinjected vol does not include volumes of Oooguruk Gas production reflected on line 17. Line 6 is Oooguruk sales 0 Nikaitchuq sales 41,745, and Air Force Power generation sale 600. Line 18 is Oooguruk returned gas.
1 hereby certify that the foregoing is true and correct to the best of my knowledge
Signature Title Anayst, Production s Revenue Accounting NOTE: A[ volumes must be corrected to pressure of 14.65 psia
and to a temperature of 60 degrees F.
Printed Name Phone Authority 20 AAC25 235
Form 10-422 Rev. 5/2009
D3
VOLUME
DATE TIME MSCF
12/31 /2019
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #3
December-2019
PLANNED
ACTION TAKEN TO MINIMIZE
DESCRIPTION OF FLARING EVENT UNPLANNED VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
0
TOTAL OVER 1 HOUR
Planned > 1 Hour
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greaterthan 1 hour
0
Less than 1 hour
8,716
Continuous Assist
0
Pilot and Purge
21,234
TOTAL FLARED/VENTED 29,950