Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU FS 1 - BP Exploration (Alaska), Inc.STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DdSPnSITInN 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator • BP 5. Month ear of Disposition I Janua -2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 737 9. Flared or vented more than 1 hour (see instr.) 20,572 10. Pilot and Purge 31,714 11. Assist Gas 35,060 12. Fuel gas used in lease operations. 676,437 13. Other (see instructions) 0Official Use Only Authorization >1 hr: Safety 76 �-7Z- MCF 14. TOTAL VOLUME (ITEMS 6-12) 764,520 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: CGF 193,364 Commissioner Date 18. Transferred to: (Express as a negative #) CGF & CCP -73,624,524 19. Remarks: I hereby certify thaph<oregoing is true andco to the best of my knowledge. Note: All volumes must be corrected Signature — to Head of Control, BP Alaska to pressure of 14.65 psia and to a Printed Name David Knapp Phone (907) 564-5775 Date #Is temperature of 60o F. Authority 20 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SInF BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT January 2019 jUnplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 1/11/2019 0800-0900 342 Not required for events <= 1 hr Not required for events <= 1 hr 1/12/2019 0800-0830 171 TOTAL 513 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1/15/2019 1015-1200 20,572 See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments TOTAL 20,572 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 10/3/2019 1400-1405 100 Not required for events <= 1 hr Not required for events <= 1 hr 10/4/2019 1400-1405 124 TOTAL 224 Planned events greater than 1 hour DESCRIPTION OF INCIDE See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 513 Unplanned Events > 1 Hour 20,572 Planned Events < 1 hour and not 224 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 31,714 Assist 35,060 TOTAL FLARED VOLUME 88,083 ACTION TAKEN TO ELIMINATE CAUSE See Attachments Page 3 2/13/2019 12:55 PM Flare Start Date 01/01/2019 Flare End Date 01/31/2019 FS1 Flare Report Total Volume (MSCF) 21309 Report Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 19-23 Flare Relief 01/15/2019 10:15:00 am 12:00:00 pm 105 min No Determination Cause CGF S/D due to power outage Action Taken Shut in high GOR wells No No BP1\BELLZO 20572 Total Volume (MSCF) 21309 Generated 02/06/2019 9:23:02AM Page 3 of 8 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PROni inrn rAc niennerrir,wi Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SInF BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT February 2019 jUnplanned events less than or equal to 1 hour DATE 2/24/2019 TIME 0115-0145 VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 2/24/2019 3,021 Not required for events <= 1 hr Not required for events <= 1 hr 0415-0445 3,021 2/24/2019 0530-0545 1,511 2/25/2019 1900-2000 5,921 TOTAL 13,474 nned events greater than 1 hour ""' r I imt VOLUME DESCRIPTION OF INI See Attachments TOTAL 0 See Attachments Planned events less than or equal to 1 hour DATE TIME 2/16/2019 VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 0220-0245 395 Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 395 Planned events greater than 1 hour DATE TIME 2/5/2019 0800-1100 VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 1,000 See Attachments See Attachments TOTAL 1,000 TOTAL Unplanned Events < 1 Hour 13,474 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 395 exceeding 5,000 MCF Planned Events > 1 hour or 1,000 exceeding 5,000 MCF Pilot Purge 28,401 Assist 43,096 TOTAL FLARED VOLUME 86,366 Page 3 3/12/2019 3:34 PM Flare Start Date 02/01/2019 Flare End Date 02/28/2019 Report FS1 Flare Report Total Volume (MSCF) 14869 Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 19-30 Flare Relief 02/05/2019 8:00:00 am 11:00:00 am 180 min No No Yes BP1tLATTNEPJ 1000 Determination Cause 1825 shutdown for planned Shutdown to light 5th stage pilots. Action Taken Loaded STV/IP T/C, Generated 03/04/2019 2:5217PM Page 3 of 5 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED rAS n1Spn-qiT1nN 1. Facility Number 2. Facility Name 0290000028 PBU FS 1 Disposition 6. Sold 7. Reinjected 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 11. Assist Gas 12. Fuel gas used in lease operations. 13. Other (see instructions) 14. TOTAL VOLUME (ITEMS 6-12) 15. NGL Gas Equivalent 16. Purchased gas 17. Transferred from: CGF 18. Transferred to: (Express as a negative #) CGF & CCP 19. Remarks: I hereby certify that!t M-fgCgoing is truR and j;orrect to the best of my Printed Name David Kna 3. Field PBU - EOA Volume MCF- 7 0 30,459 41,838 602,049 0 Authori 674,346 0 Waste: 177,793 -61, 967, 362 Phone (907) 564-5775 Date 4. Operator 5. MonthNear of Disposition BP I March-2019 production from multiple pools, list contribution of each pool as a percent of Total Volume. Pool Name Pool Code Percent PRUDHOE 640150 100.00% Official Use Safety Lease Use Commissioner MCF MCF MCF MCF Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Form 10-422 Rev. 5/2009 wSTPI icTinNc nti RwGocc cinc: BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT March 2019 Lplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Unplanned events greater than 1 hour TOTAL 0 Planned events less than or equal to 1 hour DESCRIPTION OF IN See Attachments DESCRIPTION OF INCIDENT & CAUSE Not required for events <= 1 hr ACTION TAKEN TO ELIMINATE See Attachments ACTION TAKEN TO ELIMINATE CAUSI Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 30,459 Assist 41,838 TOTAL FLARED VOLUME 72,297 Page 4 4/14/2019 3:00 PM STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITI[)N 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator BP 5. MonthNear of Disposition I Aril-2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected O PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 17,267 10. Pilot and Purge 32,208 11. Assist Gas 88,937 12. Fuel gas used in lease operations. 627,768 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: / % / Safety /-7 Z67 l MCF 14. TOTAL VOLUME (ITEMS 6-12) 766,180 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: CGF 175,265 Commissioner Date 18. Transferred to: (Express as a negative #) CGF & CCP -68,225,665 19. Remarks: I hereby certify th foregoing is true and rrect to the best of my knowledge. � Note: All volumes must be corrected Signature Title Head of Control BP Alaska to pressure of 14.65 psia and to a Printed Name David Knapp Phone (907) 564-4694 Date temperature of 60o F. Authority 20 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SInF BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT April 2019 jUnplanned events less than or equal to 1 hour ^I11VIC vULUnnt MSCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 4/10/2019 1300-1530 17,267 See Attachments See Attachments TOTAL 17,267 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events > 1 Hour 17,267 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 32,208 Assist 88,937 TOTAL FLARED VOLUME 138,412 Page 4 5/ 11 /2019 11:54 AM Flare Start Date 04/01/2019 Flare End Date 04/30/2019 FS1 Flare Report Report Total Volume (MSCF) 17267 Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 19-81 Flare Relief 04/10/2019 1:00:00 pm 3:30:00 pm 150 min No No No BP1\SDFFWC 17267 Determination Cause High gas transit line pressure caused by CGF compressor problems due to 1802 Booster Action Taken _ Shut in wells, 15-08, 02-40, 15-28,02-09, 15-14, 18-11 and 15-22. Daily Volume (MSCF) 17267 Total Volume (MSCF) 17267 Generated 05/05/2019 2:12:32PM Page 6 of 12 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator BP 5. MonthNear of Disposition I Ma -2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected O PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 37,254 9. Flared or vented more than 1 hour (see instr.) 4,394 10. Pilot and Purge 34,166 11. Assist Gas 116,027 12. Fuel gas used in lease operations. 573,766 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: [/ Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 765,607/�I(� Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: CGF 168,957 Commissioner Date 18. Transferred to: (Express as a negative #) CGF 8 CCP -58,947,984 19. Remarks: I hereby certify t e foregoing is tr�e and correct to the best of my knowledge. („_, �_ , Note: All volumes must be corrected Signature "d"r—' Title Head of Control BP Alaska to pressure of 14.65 psia and to a Printed Name David Knapp Phone (907) 564-4694 Date temperature of 60o F. Authority 20AA 2 .2 35. Form 10-422 Rev. 5/2009 INSTRI Ir-TIr1NC OKI PP\/PPcG clnr BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT May 2019 jUnplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5/13/2019 1630-1700 4,688 Not required for events <= 1 hr Not required for events <= 1 hr 5/22/2019 1700-1800 27,250 5/30/2019 2015-2050 4,861 TOTAL 36,799 L nplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 (Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5/18/2019 1400-1500 455 Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 455 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5/10/2019 1215-1345 750 See Attachments See Attachments 5/14/2019 1255-1417 3,644 TOTAL 4,394 TOTAL Unplanned Events < 1 Hour 36,799 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 455 exceeding 5,000 MCF Planned Events > 1 hour or 4,394 exceeding 5,000 MCF Pilot Purge 34,166 Assist 116,027 TOTAL FLARED VOLUME 191,841 Page 3 6/10/2019 4:30 PM Flare Start Date 05/01/2019 Flare End Date 05/31/2019 FS1 Flare Report Total Volume (MSCF) 41648 Report Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 19-107 Other 05/10/2019 12:15:00 pm 1:45:00 pm 90 min No No Yes BP1\HUNTL2 750 Determination Cause T\C depressured for water wash Action Taken Completed Water Wash 19-111 Other 05/14/2019 12:55:00 pm 2:17:00 pm 82 min No Determination Cause T\C depressu red for water wash Action Taken Completed Water Wash No Yes BP1\HUNTL2 3644 Total Volume (MSCF) 41648 Generated 06/04/2019 9:21:23AM Page 3 of 7 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCM roS niSpn-Q1T1nti 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator BP 5. MonthNear of Disposition June-2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 5,519 9. Flared or vented more than 1 hour (see instr.) 10,000 10. Pilot and Purge 33,044 11. Assist Gas 118,774 12. Fuel gas used in lease operations. 556,955 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: r9*11 Safety I0 DOc) MCF 74. TOTAL VOLUME (ITEMS 6-72) 724,292 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: CGF 145,917 I Z Commissioner Date 18. Transferred to: (Express as a negative #) CGF & CCP -50,968,170 19. Remarks: I hereby certify tha oregoing is true and cgrrect to the best of my knowledge. Note: All volumes must be corrected Signature Title Head of Control, BP Alaska to pressure of 14.65 psia and to a I g, , Printed Name David Knapp Phone (907) 564-4694 Date temperature of 60o F. Authority 20AA 2 .2 35. Form 10-422 Rev. 5/2009 INRTRI irTinti z nni RFvr:occ cinc BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT June 2019 jUnplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT &CAUSE ACTION TAKEN TO ELIMINATE CAUSE 6/27/2019 1500-1545 985 Not required for events <= 1 hr Not required for events <= 1 hr 6/28/2019 1330-1400 534 TOTAL 1,519 jUnplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 (Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT &CAUSE ACTION TAKEN TO ELIMINATE CAUSE 6/23/2019 0500-0600 4,000 Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 4,000 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 6/23/2019 1530-1921 10,000 See Attachments See Attachments TOTAL 10 000 Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME TOTAL 1, 519 0 4,000 10,000 33,044 118,774 167,337 Page 3 7/15/2019 1:49 PM Flare Start Date 06/01/2019 Flare End Date 06/30/2019 Report FS1 Flare Report Total Volume (MSCF) 15519 Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 19-147 Flare Relief 06/23/2019 3:30:00 pm 7:21:00 pm 231 min No No Yes BP1\LYLEPE 10000 Determination Cause DS12 shut and depressured for planned maintenance. Action Taken Completed depressuring. Total Volume (MSCF) 15519 Generated 07/09/2019 4:06:38PM Page 3 of 8 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DiSPORITinN 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator BP 5. MonthNear of Disposition I Jul -2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 20,448 9. Flared or vented more than 1 hour (see instr.) 6,025 10. Pilot and Purge 34,517 11. Assist Gas 111,198 12. Fuel gas used in lease operations. 550,607 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety � OZS MCF 14. TOTAL VOLUME (ITEMS 6-12) 722,795 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: CGF 157,057� / Commissioner Date 18. Transferred to: (Express as a negative # CGF & CCP p g ) -38,118,142 19. Remarks: I hereby certify that the foregoing is true d correct to the best of my knowledge. Note: All volumes must be corrected Signature Title Manager Production Taxes and Rovalties Alaska to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Mark Littlefield Phone (907) 564-5775 Date 0 ( AAC25.235. Form 10-422 Rev. 5/2009 wcTPI irnntis nni QwGocG cinc: BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT July 2019 jUnplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/11/2019 1048-1145 7,917 Not required for events <= 1 hr Not required for events <= 1 hr 7/12/2019 1048-1145 4,363 TOTAL 12,280 jUnplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/22/2019 1202-1305 2,068 See Attachments See Attachments 7/30/2019 1130-1240 2,431 TOTAL 4,499 1131anned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/4/2019 1730-1830 74 Not required for events <= 1 hr Not required for events <= 1 hr 7/4/2019 1730-1830 203 7/12/2019 2247-2315 492 7/18/2019 1543-1407 3,007 7/22/2019 1433-1456 4,392 TOTAL 8,168 (Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/25/2019 0955-1125 1,526 See Attachments See Attachments TOTAL Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME TOTAL 12,280 4,499 8,168 1,526 34,517 111,198 172,188 Page 3 8/ 13/2019 3:14 PM 6 to y G6ed Wd9b Lb £ 61.0Z/LO/80 paleaauaE) £L179Z (3oSW) awnloq le;ol 1708L paPeol Pue pauelsaa uamel uol;ay alnpow awgjnl ayi w ainiejadwal lewiayi u6lq qj!m paleloosse walgwd a of anp uMopinys b08L Z)\1 asneC) uol;eulwja;ap L£bZ 3d31Al\Ld8 ON ON ON ulw 0l wd 00 Ob ZL we 00 0£ L L 6LOZ/0£/LO umopmo 18 PGllojluoo 61,Z-61, 6uunssaidep palaldwoo uajej u0143y ails llup epl amssaadap of 6uuell 'Goueualulew pauueld jol 4/S BLSIJ asneo uol;euma;aQ 9Z9 L 3d3lAl\ Ld8 sa k ON ON uiw 06 we 00 SZ L L We 00 99 6 6 LOZ/9Z/LO u-o mo P 18 PGllojlu03 L LZ-6 L ------------- C)03 jad se 'Pla!l ayi jol 6uuell palaldwoo ua)lel uollob a6eino iamod lueld leiol of anp swalgad jossaidwoo 3E)o Aq pasneo amssaid Gull llsue-ll se6 y61H 8sne3 uol;eulwja;aa 890Z 3d37lAl\I.d8 ON ON ON ww 89 wd 00 90 L wd 00 ZO ZL 6LOZ/ZZ/LO unno nno — P 18 PGllaiuo3 90Z-6 L awnloq AS papodaa pauueld 03lowS 313e19 ;uaMi.wa;ul uol;ejna awl1 3S awl do 1 jjeaS ale(] wa;sAS agwnry £L49Z (3OSlry) awnloq le;ol podab podab 9ael.1 TSB 6L0Z/L£/Lo a;ea pu3 ajel3 6LOZ/Lo/Lo a;ea jje;S ajel j STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DiSpnSiTinN 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator •r BP Mon Near of Disposition Au ust-2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold � Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 2,523 9. Flared or vented more than 1 hour (see instr.) 0 10. Pilot and Purge 35,010 11. Assist Gas 116,503 12. Fuel gas used in lease operations. 568,662 13. Other (see instructions) 0Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 722,698 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: CGF 174,910 Commissioner Date 18. Transferred to: (Express as a negative #) CGF & CCP -46,292,434 19. Remarks: I hereby certify that the foregoing is true and rrect to the st of my knowledge. Note: All volumes must be corrected Signature G� Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Mark Littlefield Phone (907) 564-5775 Date Zell AA 25.23 . Form 10-422 Rev. 5/2009 INSTRUCTIONS ON RFVFRSF ainF SP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT August 2019 jUnplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 8/5/2019 1000-1003 35 Not required for events <= 1 hr Not required for events <= 1 hr 8/7/2019 2131-2215 1,797 8/29/2019 1020-1110 387 TOTAL 2,219 junplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ^� ACTION TAKEN. TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 8/24/2019 1059-1131 304 Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 304 Planned events greater than 1 hour DATE TOTAL Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME VOLUME DESCRIPTION OF INCIDENT See Attachments 0 TOTAL 2,219 0 304 0 35,010 116,503 154,036 ALTIUN TAKEN TO ELIMINATE See Attachments Page 4 9/13/2019 10:26 AM STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator BP 5. MonthNear of Disposition Se tember-2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume, 6. Sold Pool Name Pool Code Percent 7. Reinjected O PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 1,428 9. Flared or vented more than 1 hour (see instr.) 18,794 10. Pilot and Purge 34,092 11. Assist Gas 103,009 12. Fuel gas used in lease operations. 554,578 13. Other (see instructions) 0Official Use Only Authorization >1 hr: Py��15. j Safety i l MCF 14. TOTAL VOLUME (ITEMS 6-12) 711,901 Lease Use MCF NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: T MCF 17. Transferred from: CGF 163,709cfv- Commissioner Date 18. Transferred to: (Express as a negative #) CGF & CCP -45,769,059 19. Remarks: I hereby certify that the foregoing is true arld correct to the best of my knowledge. 1 Note: All volumes must be corrected Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 Asia and to a temperature of 60o F. Authority 20 Printed Name Mark Littlefield Phone (907) 564-5775 Date O / 2v AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS nN RFVFRCF CIr1F BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT- FS-1 GAS FLARING AND VENTING INCIDENT REPORT September 2019 (Unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 9/23/2019 2255-2313 875 Not required for events <= 1 hr Not required for events <= 1 hr 9/24/2019 1520-1606 553 TOTAL 1,428 jUnplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 9/6/2019 1350-1605 14,905 See Attachments See Attachments 9/22/2019 2130-2240 3,889 TOTAL 18,794 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour E DESCRIPTION OF INi See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 1,428 Unplanned Events > 1 Hour 18,794 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 34,092 Assist 103,009 TOTAL FLARED VOLUME 157,323 CAUSE ACTION TAKEN TO E See Attachments Page 4 10/15/2019 10:03 AM Flare Start Date 09/01/2019 Flare End Date 09/30/2019 Report FS1 Flare Report Total Volume (MSCF) 20222 Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 19-282 Flare Relief 09/06/2019 1:50:00 pm 4:05:00 pm 135 min No No No BPIIHNL5C5 14905 Determination Cause Nigh gas transit line pressure caused by CGF compressor problems due to losing all Tandems Action Taken Shut in wells, 19-299 Flare Relief 09/22/2019 9:30:00 pm 10:40:00 pm 70 min No No No BP11OTTOKL 3889 Determination Cause LPS T\C 1804 shutdown because of IGV fault Action Taken Shut in wells, 5-23 18-27 2-15 5-27 2-20 18-3 2-19 Generated 10/08/2019 3:17:38PM Page 4 of 9 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator BP 5. MonthNear of Disposition I October-2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume, 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 21,086 9. Flared or vented more than 1 hour (see instr.) 10,481 10. Pilot and Purge 35,361 11. Assist Gas 94,971 12. Fuel gas used in lease operations. 556,008 13. Other (see instructions) 0Official Use Only Authorization >1 hr: d �,/ql I 1(/ /"/,/� Safety (O � ) I MCF 14. TOTAL VOLUME (ITEMS 6-12) 717,907 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: CGF 174,747 Commissioner Date 18. Transferred to: (Express as a negative #) CGF & CCP -55,905,313 19. Remarks: I hereby certify that the foregoing is tru nd c rrect to the best of my knowledge. Note: All volumes must be corrected Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a Printed Name Mark Littlefield Phone (907) 564-5775 Date temperature of 60o F. Authority 20 /� el . AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON RFVFRSF SInF BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT October 2019 junplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/5/2019 1435-1515 3,453 Not required for events <= 1 hr 10/20/2019 1223-1300 6,860 10/21/2019 0734-0814 4,166 10/21/2019 2016-2111 5,729 TOTAL 20,208 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/21/2019 0734-1200 1,293 See Attachments 10/22/2019 0215-0330 7,161 TOTAL 8,454 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/16/2019 1632-1654 878 Not required for events <= 1 hr TOTAL 878 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/14/2019 0148-0423 2,027 See Attachments TOTAL 7 n? TOTAL Unplanned Events < 1 Hour 20,208 Unplanned Events > 1 Hour 8,454 Planned Events < 1 hour and not 878 exceeding 5,000 MCF Planned Events > 1 hour or 2,027 exceeding 5,000 MCF Pilot Purge 35,361 Assist 94,971 TOTAL FLARED VOLUME 161,899 ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr ACTION TAKEN TO ELIMINATE CAUSE See Attachments AL I WIM I AKEN TO ELIMINATE CAUSE Not required for events <= 1 hr See Attachments CAUSE Page 4 11 /17/2019 1:15 PM Flare StartDate 10/01/2019 Flare End Date 10/31/2019 FS1 Flare Report Report Total Volume (MSCF) 31567 Numbe System Date Start Time Stop Time Duration intermittent Black Smoke Planned Reported By Volume 19-339 Flare Relief 10/14/2019 1:48:00 am 4:23:00 am 155 min No ----------------- No Yes BP1\HNL5C5 2027 Determination Cause 1803 spin cooling for water wash Action Taken Completed spin cooling. 19-355 Flare Relief 10/21/2019 7:34:00 am 12:00:00 pm 266 min No No No BP1\HUNTL2 1293 Determination Cause STV-IP T\C 1825 shutdown due to a problem associated with power outage Action Taken Loaded STV/IP T/C. 19-357 Flare Relief 10/22/2019 2:15:00 am 3:30:00 am 75 min No No No BP1\HNL5C5 7161 Determination Cause High gas transit line pressure caused by CGF low temperature separator problems. Action Taken Completed depressuring. Total Volume (MSCF) 31567 Generated 11/O8/2019 11:44:02AM Page 6 of 12 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REP[)RT fly pRnnl irCn f- A r,��+.,..�..�..... Form 10-422 Rev. 5/2009 INSTRI1CTlnnlc Ml orwroc� BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT November 2019 jUnplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 71 Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 11/22/2019 0506-0609 10,981 See Attachments See Attachments TOTAL 10,981 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events > 1 Hour 10,981 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 34,011 Assist 79,771 TOTAL FLARED VOLUME 124,763 Page 3 12/14/2019 3:48 PM Flare Start Date 11/01/2019 Flare End Date 11/30/2019 FS1 Flare Report Report Total Volume (MSCF) 10981 Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 19-401 Flare Relief 11/22/2019 5:06:00 am 6:09:00 am 63 min No No No BP1\MCCADJ 10981 Determination Cause High gas transit line pressure caused by CGF compressor problems Action Taken Shut in wells and/or CGF T/C restarted. Generated 12/03/2019 2:48:43PM Total Volume (MSCF) 10981 Page 4 of 9 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PROnl l[-Fn r,ec n1cDinc1T1lnK1 1. Facility Number 0290000028 2. Facility Name PBU FS 1 3. Field PBU - EOA 4. Operator BP 5. MonthNear of Disposition I December-2019 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 0 10. Pilot and Purge 34,870 11. Assist Gas 82,225 12. Fuel gas used in lease operations. 623,074 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 740,169 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: CGF 196,572 Commissioner Date 18. Transferred to: (Express as a negative #) CGF & CCP -66,398,351 19. Remarks: I hereby certify that the foregoing is true and cc 06ct to th b of my knowledge. Note: All volumes must be corrected Signature G Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a - temperature of 60o F. Authority 20 Printed Name Mark Littlefield Phone (907) 564-5775 Date / X, kwo AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON RFVFRSF cinF BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-1 GAS FLARING AND VENTING INCIDENT REPORT December 2019 Unplanned events less than or equal to 1 hour DESCRIPTION OF INCIDENT & CAUSE Not required for events <= 1 hr TOTAL 0 Unplanned events greater than 1 hour DATE ACTION TAKEN TO ELIMINATE CAUSI Not required for events <= 1 hr TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 34,870 Assist 82,225 TOTAL FLARED VOLUME 117,095 Page 3 1 /15/2020 2:45 PM