Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutPBU GC 3 - BP Exploration (Alaska), Inc.STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000033
2. Facility Name
PBU GC 3
3. Field
PBU - WOA
4. Operator
BP
5. MonthNear of Disposition
I Janua -2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
6,736
10. Pilot and Purge
23,435
11. Assist Gas
0
12. Fuel gas used in lease operations.
534,845
13. Other (see instructions)
0
Official Use Only
Authorization >1 hr:
/G! ��` ��
Safety
`
C
/
MCF
14. TOTAL VOLUME (ITEMS 6-12)
565,016
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
0
Waste:
MCF
17. Transferred from:
0
/
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-25,507,420
14
19. Remarks:
I hereby certify th oregomg is true and correct to the best of my knowledge.
Note: All volumes must be corrected
Signature Title Head of Control, BP Alaska to pressure of 14.65 psia and to a
Printed Name David Knapp Phone (907) 564-5775 Datemperature of 60o F. Authority 20
te Z �� AAC25.235.
Form 10-422 Rev. 5/2009 INCTRI Ir TIr1NC ON] RF\/FRCG crow
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
January 2019
jUnplanned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 0
Unplanned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
1/15/2019 1014-1151 6,736 See Attachments See Attachments
TOTAL 6,736
Planned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 0
Planned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
See Attachments See Attachments
TOTAL 0
TOTAL
Unplanned Events < 1 Hour 0
Unplanned Events > 1 Hour 6,736
Planned Events < 1 hour and not 0
exceeding 5,000 MCF
Planned Events > 1 hour or 0
exceeding 5,000 MCF
Pilot Purge 23,435
Assist 0
TOTAL FLARED VOLUME 30,171
Page 8
2/13/2019
12:55 PM
Flare Start Date 01/01/2019
Flare End Date 01/31/2019
GC3 Flare Report Total Volume (MSCF) 6736
Report
Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
riare Keuer 01/15/2019 10:14:00 am 11:51:00 am 97 min Yes No No BP1\MARTINJE 6736
Determination Cause High gas transit line pressure caused by CGF compressor problems due to power failure.
Action Taken _ PCC shut in wells and reduced chokes on wells to reduce rate here on WOA side of the field until CGF power was re -stored and
,-
Total Volume (MSCF) 6736
jenerated 02/06/2019 9:23:02AM
Page 8 of 8
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODIMM ro-qnicpnQ1TinK1
1. Facility Number 2. Facility Name
0290000033 PBU GC 3
Disposition
3. Field
PBU - WOA
Volume MCF
4. Operator 5. Month/Year of Disposition
BP Februa -2019
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
26,574
11. Assist Gas
0
12. Fuel gas used in lease operations.
482,072
13. Other (see instructions)
0
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-12)
508,646
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
0
Waste:
MCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-21,528,097
19. Remarks:
I hereby certify thA.14e foregoing is trVp a correct to the best of my knowledge.
Note: All volumes must be corrected
SignatureA Title Head of Control BP Alaska to pressure of 14.65 psia and to a
Printed Name David Knapptemperature of 60o F. Authority 20
Phone (907) 564-5775 Date AAC25.235.
Form 10-422 Rev, 5/2009 INSTRUCTIONS ON REVERSE SIDE
events less than or equal to 1 hour
nned events
neo events
DATE
nned events
TOTAL
Ater than 1— hour
TOTAL
in or equal to 1 hour
TOTAL
IMM-SROR--ho
than 1
TOTAL
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
February 2019
Not required for events <= 1 hr
3-
See Attachments
0
uca'-KIFU1ON OF INCIDENT— g,- CAVM
Not required for events <= 1 hr
0
See Attachments
0
TOTAL
0
0
0
0
26,574
0
26,574
Not required for events <= 1 hr
See Attachments
"J ranwINATE CAUSE
Not required for events <= 1 hr
See Attachments
Page 8
3/12/2019
`-IA n..
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000033
2. Facility Name
PBU GC 3
3. Field
PBU - WOA
4. Operator
BP
5. MonthNear of Disposition
I March-2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
680
10. Pilot and Purge
28,401
11. Assist Gas
0
12. Fuel gas used in lease operations.
532,754
13. Other (see instructions)
p
Official Use Only
Authorization >1 hr:
_/ G / /�
Safety
�
MCF
14. TOTAL VOLUME (ITEMS 6-12)
561,835
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
0
Waste:
MCF
17. Transferred from:
6
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-24,030,566
19. Remarks:
I hereby certify tha foregoing is true and correit to the best of my knowledge.
Note: All volumes must be corrected
SignatureTitle Head of Control BP Alaska to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
Printed Name David Knapp Phone (907) 564-5775 Date AAC25.235.
Form 10-422 Rev. 5/2009 INSTRI1CTInNC nKJ RF\/FRCP Ring
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
March 2019
jUnplanned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
Page 9
TOTAL
0
Unplanned events greater than 1 hour
DATE TIME
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
See Attachments
TOTAL
0
Planned events less than or equal to 1 hour
DATE TIME
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
Not required for events <= 1 hr
TOTAL
0
Planned events greater than 1 hour
DATE TIME
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
3/12/2019 0400-0545
680
See Attachments
See Attachments
TOTAL
680
TOTAL
Unplanned Events < 1 Hour
0
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
0
exceeding 5,000 MCF
Planned Events > 1 hour or
680
exceeding 5,000 MCF
Pilot Purge
28,401
Assist
0
TOTAL FLARED VOLUME
29,081
4/14/2019
3:00 PM
Flare Start Date 03/01/2019
Flare End Date 03/31/2019
GC3 Flare Report
Total Volume (MSCF)
680
Report
Numbe System
Date Start Time Stop Time Duration Intermittent
Black Smoke Planned Reported By
Volume
19-57 Flare Relief 03/12/2019 4:00:00 am 5:45:00 am 105 min Yes
No Yes BP1\MARTINJE
680
Determination Cause
Shutdown HP production to repair a leak in skid-4.
Action Taken
Repair completed.
Total Volume (MSCF)
680
Generated 04/02/2019 10:10:59AM
Page 5 of 5
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PROM mim [,oS n1cpnc1T1nK1
1. Facility Number 2. Facility Name
PBU GC 3
Disposition
- - -- - -
Id
PBU WOA
Volume MCF
--- -- -- - - _-...�@v
BPperator MonthNear of Disposition0290000033
5Aril-2019
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
120
9. Flared or vented more than 1 hour (see instr.)
1,800
10. Pilot and Purge
25,090
11. Assist Gas
0
12. Fuel gas used in lease operations.
434,444
13. Other (see instructions)
0Official
Use Only
Authorization >1 hr:
///�(�
Safety
� 0
r
MCF
14. TOTAL VOLUME (ITEMS 6-12)
461,454
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
0
Waste:
MCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-23,734,548
19. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
` Note: All volumes must be corrected
Signature Title Head of Control BP Alaska to pressure of 14.65 psia and to a
Printed Name David Knapp Phone (907) 564-4694 Date temperature of 60o F. Authority 20A 2 2
35.
Form 10-422 Rev. 5/2009 INSTRUCTinNs nKi RFVFRRF sing
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
April 2019
jUnplanned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
4/29/2019 1727-1800 120 Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 120
Unplanned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
See Attachments See Attachments
Page 9
TOTAL
0
Planned events less than or equal to 1 hour
DATE TIME
VOLUME DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
Not required for events <= 1 hr
TOTAL
0
Planned events greater than 1 hour
DATE TIME
VOLUME DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
4/3/2019 1325-1657
1,800 See Attachments
See Attachments
TOTAL
1,800
TOTAL
Unplanned Events < 1 Hour
120
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
0
exceeding 5,000 MCF
Planned Events > 1 hour or
1,800
exceeding 5,000 MCF
Pilot Purge
25,090
Assist
0
TOTAL FLARED VOLUME
27,010
5/11 /2019
11:54 AM
Flare Start Date 04/01/2019
Flare End Date 04/30/2019
Report GC3 Flare Report
Total Volume (MSCF) 1920
Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
19-75 Flare Relief 04/03/2019 1:25:00 pm 4:57:00 pm 212 min No
No Yes BP1\MARTINJE 1800
Determination Cause Spin to cool turbine for water wash
Action Taken Completed cool down
Daily Volume (MSCF) 1800
Total Volume (MSCF) 1920
Generated 05/05/2019 2:12:32PM
Page 12 of 12
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000033
2. Facility Name
PBU GC 3
3. Field
PBU - WOA
4. Operator
BP
5. MonthNear of Disposition
I Ma -2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
27,797
11. Assist Gas
0
12. Fuel gas used in lease operations.
531,541
13. Other (see instructions)
0
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-12)
559,338
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-25,444,106
19. Remarks:
I hereby certify that a foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected
Signature Title Head of Control. BP Alaska to pressure of 14.65 psia and to a
Printed Name David Knapp Phone (907) 564-4694 Date temperature of 60o F. Authority 20
AAC25.235.
Form 10-422 Rev. 5/2009 INRTRI IrtTIr)NS r)KI RFVCI7CC cinr-
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
May 2019
nplanned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
Not required for events <= 1 hr
ACTION TAKEN TO ELIMINATE CAUSI
Not required for events <= 1 hr
TOTAL p
Unplanned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
See Attachments See Attachments
TOTAL 0
Planned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 0
nned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF IN;
See Attachments
TOTAL 0
TOTAL
Unplanned Events < 1 Hour
0
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
0
exceeding 5,000 MCF
Planned Events > 1 hour or
0
exceeding 5,000 MCF
Pilot Purge
27,797
Assist
0
TOTAL FLARED VOLUME
27,797
CAUSE
ACTION TAKEN TO ELIMINATE
See Attachments
Page 8
6/10/2019
4:30 PM
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITI(W
1. Facility Number
0290000033
2. Facility Name
PBU GC 3
3. Field
PBU - WOA
4. Operator
BP
5. MonthNear of Disposition
June-2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
23,186
11. Assist Gas
0
12. Fuel gas used in lease operations.
501,978
13. Other (see instructions)
0
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-12)
525,164
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
0
Waste:
jMCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-24,301,116
19. Remarks:
I hereby certify oregoing Is true and orrect to the best of my knowledge.
�---� Note: All volumes must be corrected
Signature Title Head of Control BP Alaska to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
Printed Name David Knapp Phone (907) 564-4694 Date t 8 AA 2 .23 .
Form 10-422 Rev. 5/2009 INRTRI 1r.TinKj.q r1N RFVFacG cinr
nplanned events less than or equal to 1 hour
DATE TIME VOLUME
nplanned events
TOTAL
Iter than 1 our
TIME
TOTAL
anned events less than or equal to 1 hour
DATE TIME v
ned events
DATE
TOTAL
mnmw—m-w�
r than 1 hour
MNMMNw=wMMMwTIME
TOTAL
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
June 2019
utx KIPTION OF INCIDENT & CAUSE
Not required for events <= 1 hr
0
E DESCRIPTION OF INCIDENT & CAUSE
See Attachments
0
E DESCRIPTION OF INCIDENT & CAUSE
Not required for events <= 1 hr
0
VOLUME DESCRIPTION OF INI
See Attachments
0
TOTAL
0
0
0
0
23,186
0
23,186
AL ION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
ACTION TAKEN TO E
See Attachments
ACTION TAKEN TO ELIMINATE CAUSI
Not required for events <= 1 hr
Ht I ION TAKEN TOE
See Attachments
Page 8
7/15/2019
1:49 PM
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODL]CEn rAS ni.gPrnsiTinN
1. Facility Number
0290000033
2. Facility Name
PBU GC 3
3. Field
PBU - WOA
4. Operator
BP
5. MonthNear of Disposition
I Jul -2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
22,030
11. Assist Gas
12. Fuel gas used in lease operations.
493,084
13. Other (see instructions)
0Official
Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-12)
515,114
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: Ex ress as a negative # CGF
(Express 9 )
-19,498,462
19. Remarks:
I hereby certify that the foregoing is true and rect to t best of my knowledge.
��G, Note: All volumes must be corrected
Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psis and to a
Q temperature of 60o F. Authority 20
Printed Name Mark Littlefield Phone (907) 564-5775 Date Olt AAC25.235.
Form 10-422 Rev. 5/2009 a icTPJ irTinnic nni owCoec --
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
July 2019
jUnplanned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
Page 8
TOTAL
0
Unplanned events greater than 1 hour
DATE TIME
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
See Attachments
TOTAL
0
Planned events less than or equal to 1 hour
DATE TIME
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
Not required for events <= 1 hr
TOTAL
0
Planned events greater than 1 hour
DATE TIME
VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
See Attachments
TOTAL
0
TOTAL
Unplanned Events < 1 Hour
0
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
0
exceeding 5,000 MCF
Planned Events > 1 hour or
0
exceeding 5,000 MCF
Pilot Purge
22,030
Assist
0
TOTAL FLARED VOLUME
22,030
8/13/2019
3:14 PM
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PROni im=n rec n1cDnc1r1nK1
1. Facility Number 2. Facility Name
0290000033 PBU GC 3
Disposition
3. Field
PBU - WOA
Volume MCF
4. Operator 5. MonthNear of Disposition
BP Au ust-2019
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
15,611
10. Pilot and Purge
21,301
11. Assist Gas
0
12. Fuel gas used in lease operations.
434,163
13. Other (see instructions)
Official Use Only
Authorization>1 hr:
7 r
110,'Z��/�� %
safety
j v
2—( �
MCF
14. TOTAL VOLUME (ITEMS 6-12)
471,075
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
6
Commissioner Dater
18. Transferred to: (Express as a negative #) CGF
-20,949,897
19. Remarks:
I hereby certify that the foregoing is true and c rrect to e e of my knowledge.
Note: All volumes must be corrected
Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psis and to a
temperature of 60o F. Authority 20
Printed Name Mark Littlefield Phone (907) 564-5775 Date 9— 7 -Z,11 f AAC25.235.
Form 10-422 Rev. 5/2009 inicroi irrin is — --- -,--
Unplanned events less than or equal to 1 hour
DATE TIME Vol 1
TOTAL
Unplanned events greater than 1 hour
DATE TIME
8/1/2019 1000-1558
8/5/2019 0845-1822
TOTAL
Planned events less than or equal to 1 hour
DATE TIME
lanned events
DATE
8/24/2019
TOTAL
ter than 1 hour
TIME
0131-0430
TOTAL
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
August 2019
DESCRIPTION OF INCIDENT & CAUSE
Not required for events <= 1 hr
t7
Mt DESCRIPTION OF INCIDENT &
1,100 See Attachments
10,160
11,260
DESCRIPTION OF INCIDENT & CAUSE
Not required for events <= 1 hr
1
ME DESCRIPTION OF INCIDENT & CAUSE
4,351 See Attachments
4,351
TOTAL
0
11,260
0
4,351
21,301
0
36,912
ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
ACTION TAKEN TO ELIMINATE
See Attachments
ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
ACTION TAKEN TO E
See Attachments
Page 9
9/13/2019
10:26 AM
Flare StartDate 08/01/2019
Flare End Date 08/31/2019
GC3 Flare Report
Report
Total Volume (MSCF) 15611
Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume
19-224 Flare Relief 08/01/2019 10:00:00 am 3:58:00 pm 358 min Yes
No No BPIIMOORDV 1100
Determination Cause Shut in "C" pad so depressuring lines to plant
Action Taken No response taken as this was deemed to be of short duration.
19-227 Flare Relief 08/05/2019 8:45:00 am 6:22:00 pm 577 min Yes
NO No BPIIMOORDV 10160
Determination Cause Pressure testing "C" pad after S/D
Action Taken After pressure test was completed flare valve on "A" S/C put back to normal.
19-261 Flare Relief 08/24/2019 1:31:00 am 4:30:00 am 179 min No ---------------
No Yes BP1\MARTINJE 4351
Determination Cause Taking advantage of TAPS shutdown we de -pressured HP separator for maintenance and work.
Action Taken Completed de -pressuring HP.
Total Volume (MSCF) 15611
Generated 09/06/2019 9:55:18AM
Page 12 of 12
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY RFPnRT n1= PPnni InCr% f%— A 0
Form 10-422 Rev. 5/2009 INSTRI IrTir'%nfc nni
nplanned events less than or equal to 1 hour
DATE TIME VOLUME
TOTAL
Unplanned events greater than 1 hour
DATE TIME
9/26/2019 1359-1800
TOTAL
Planned events less than or equal to 1 hour
DATE TIME u
TOTAL
anned events greater than 1
DATE TO MR M,.M
TOTAL
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
September 2019
ut,SCRIPTION OF INCIDENT & CAUSE
Not required for events <= 1 hr
C
DESCRIPTION OF INi
60 See Attachments
60
utsCKIPTION OF INCIDENT & CAUSE
Not required for events <= 1 hr
n
E DESCRIPTION OF INCIDENT
See Attachments
I
Unplanned Events < 1 Hour
TOTAL0
Unplanned Events > 1 Hour
60
Planned Events < 1 hour and not
exceeding 5,000 MCF
0
Planned Events > 1 hour or
exceeding 5,000 MCF
0
Pilot Purge
21,293
Assist
0
TOTAL FLARED VOLUME
21,353
ACTION TAKEN TO ELIMINATE CAUSI
Not required for events <= 1 hr
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
ACTION TAKEN TO ELIMINATE CAUSI
Not required for events <= 1 hr
ACTION TAKEN TO ELIMINATE
See Attachments
Page 9
10/15/2019
10:03 AM
Flare StartDate 09/01/2019
Flare End Date 09/30/2019
GC3 Flare Report
Report Total Volume (MSCF) 60
Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported B
19-311 Flare Relief 09/26/2019 1:59:00 m 6:00:00 P p y Volume
P m 241 min Yes
Determination Cause HP separator "D" bank blow down for safe out. No No BPIIMOORDV 60
Action Taken Stopped after psi reached 0 psi.
Generated 10/08/2019 3:17:38PM
Page 9 of 9
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PROM M.Fn [,oS nicancrrinKi
1. Facility Number 2. Facility Name
0290000033 PBU GC 3
Disposition
3. Field
PBU - WOA
Volume MCF
4. Operator 5. Month/Year of Disposition
BP October-2019
20. Forproduction from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
25,137
11. Assist Gas
0
12. Fuel gas used in lease operations.
518,521
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-12)
543,658
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-21,639,205
19. Remarks:
I hereby certify that the foregoing is true and Korrect to he st of my knowledge.
Note: All volumes must be corrected
Signature �/ Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a
Printed Name Mark Littlefield temperature of 60o F. Authority 20
Phone (907) 564-5775 Date / 4J 2 G j AAC25.235_
Form 10-422 Rev. 5/2009 wcTPI 1rT1nn1c nni owcocc —,
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
October 2019
jUnplanned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 0
Unplanned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
See Attachments See Attachments
TOTAL 0
Planned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 0
Planned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
See Attachments See Attachments
TOTAL 0
TOTAL
Unplanned Events < 1 Hour 0
Unplanned Events > 1 Hour 0
Planned Events < 1 hour and not 0
exceeding 5,000 MCF
Planned Events > 1 hour or 0
exceeding 5,000 MCF
Pilot Purge 25,137
Assist 0
TOTAL FLARED VOLUME 25,137
Page 10
11 /17/2019
1:15 PM
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000033
2. Facility Name
PBU GC 3
3. Field
PBU - WOA
4. Operator
BP
15. Month/Year of Disposition
I November-2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
19,412
11. Assist Gas
0
12. Fuel gas used in lease operations.
546,171
13. Other (see instructions)
0Official
Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-12)
565,583
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-27,121,742
19. Remarks:
I hereby certify that the foregoing is true and corre o the best f m knowledge.
Note: All volumes must be corrected
Signature G < Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a
Printed Name Mark Littlefield Phone (907) 564-5775 Date temperature of 60o F. Authority 20 AA 2 .2
35,
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON RFVFRSF SinF
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
November 2019
Page 8
jUnplanned events less than or equal to 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
Not required for events <= 1 hr
TOTAL
0
Unplanned events greater than 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
See Attachments
TOTAL
0
Planned events less than or equal to 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr
Not required for events <= 1 hr
TOTAL
0
Planned events greater than 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
ACTION TAKEN TO ELIMINATE CAUSE
See Attachments
See Attachments
TOTAL
0
TOTAL
Unplanned Events < 1 Hour
0
Unplanned Events > 1 Hour
0
Planned Events < 1 hour and not
0
exceeding 5,000 MCF
Planned Events > 1 hour or
0
exceeding 5,000 MCF
Pilot Purge 19,412
Assist
0
TOTAL FLARED VOLUME 19,412
12/14/2019
3:48 PM
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
0290000033
2. Facility Name
PBU GC 3
3. Field
PBU - WOA
4. Operator
BP
15. Month/Year of Disposition
I December-2019
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
0
Pool Name
Pool Code
Percent
7. Reinjected
0
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.)
0
10. Pilot and Purge
18,603
11. Assist Gas
0
12. Fuel gas used in lease operations.
582,130
13. Other (see instructions)
0
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-12)
600,733
Lease Use
MCF
15. NGL Gas Equivalent
0
Conservation
MCF
16. Purchased gas
0
Waste:
JMCF
17. Transferred from:
0
Commissioner Date
18. Transferred to: (Express as a negative #) CGF
-29,634,225
19. Remarks:
I hereby certify that the foregoing is true and correctto the bes) of my knowledge.
i� Note: All volumes must be corrected
Signature Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
Printed Name Mark Littlefield Phone (907) 564-5775 Date AAC25.235.
Form 10-422 Rev. 5/2009 INSTRUCTIONS nN RFVFRSF CIr1F
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-3
GAS FLARING AND VENTING INCIDENT REPORT
December 2019
jUnplanned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 0
Unplanned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
See Attachments See Attachments
TOTAL 0
Planned events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
Not required for events <= 1 hr Not required for events <= 1 hr
TOTAL 0
Planned events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
See Attachments See Attachments
TOTAL 0
TOTAL
Unplanned Events < 1 Hour 0
Unplanned Events > 1 Hour 0
Planned Events < 1 hour and not 0
exceeding 5,000 MCF
Planned Events > 1 hour or 0
exceeding 5,000 MCF
Pilot Purge 18,603
Assist 0
TOTAL FLARED VOLUME 18,603
Page 9
1 /15/2020
2:45 PM