HomeMy WebLinkAbout218-022MEMORANDUM State of Alaska Alaska Oil and Gas Conservation Commission DATE:Tuesday, April 22, 2025 SUBJECT:Mechanical Integrity Tests TO: FROM:Guy Cook P.I. Supervisor Petroleum Inspector NON-CONFIDENTIAL Hilcorp Alaska, LLC F-110 MILNE PT UNIT F-110 Jim Regg InspectorSrc: Reviewed By: P.I. Suprv Comm ________ JBR 04/22/2025 F-110 50-029-23599-00-00 218-022-0 W SPT 4036 2180220 1500 496 501 499 497 REQVAR P Guy Cook 3/21/2025 MIT-IA every two years per AIO 10B.018. Mono-bore well, no OA. Testing was completed with a Little Red Services pump truck and calibrated gauges. 30 MinPretestInitial15 Min Well Name Type Test Notes: Interval P/F Well Permit Number: Type Inj TVD PTD Test psi API Well Number Inspector Name:MILNE PT UNIT F-110 Inspection Date: Tubing OA Packer Depth 433 1760 1688 1656IA 45 Min 60 Min Rel Insp Num: Insp Num:mitGDC250320215258 BBL Pumped:2.4 BBL Returned:2.4 Tuesday, April 22, 2025 Page 1 of 1 9 9 9 9 9 9 9 999 9 9 9 9 9 AIO 10B.018 James B. Regg Digitally signed by James B. Regg Date: 2025.04.22 14:52:47 -08'00' CAUTION: External sender. DO NOT open links or attachments from UNKNOWN senders. From:Wallace, Chris D (OGC) To:AOGCC Records (CED sponsored) Subject:FW: Operable - RE: Request to put Injector MPF-110 PTD #2180220 online for AOGCC MIT-IA Date:Wednesday, April 9, 2025 1:23:49 PM Attachments:MPF-110 30 day TIO.docx From: Ryan Thompson <Ryan.Thompson@hilcorp.com> Sent: Wednesday, April 9, 2025 1:22 PM To: Wallace, Chris D (OGC) <chris.wallace@alaska.gov>; Regg, James B (OGC) <jim.regg@alaska.gov> Cc: Taylor Wellman <twellman@hilcorp.com> Subject: Operable - RE: Request to put Injector MPF-110 PTD #2180220 online for AOGCC MIT-IA Mr. Wallace, PWI injector MPF-110 (PTD# 2180220) operates under AIO 10B.018 for known TxIA pressure communication. The well was placed back on injection following the 3/12/25 approval from AOGCC below. On 3/21/25 an AOGCC witnessed MIT-IA passed to 1656 psi. The well is now re-classified as Operable. The next 2 year MIT-IA per AIO 10B.018 will be due during March 2027. Attached is the 30 day TIO plot. Please respond with any questions. Thank you, Ryan Thompson Milne/Islands/WNS Well Integrity Engineer 907-564-5005 From: Wallace, Chris D (OGC) <chris.wallace@alaska.gov> Sent: Wednesday, March 12, 2025 2:20 PM To: Stephen Soroka <Steve.Soroka@hilcorp.com> Cc: jim.regg <jim.regg@alaska.gov>; Ryan Thompson <Ryan.Thompson@hilcorp.com>; Taylor Wellman <twellman@hilcorp.com>; Ryan Lewis <Ryan.Lewis@hilcorp.com> Subject: [EXTERNAL] RE: Request to put Injector MPF-110 PTD #218022 online for AOGCC MIT-IA Steve, Your request to put the well back online for monitoring and diagnostics including an AOGCC witnessed MITIA when stabilized is approved. CAUTION: This email originated from outside the State of Alaska mail system. Do not click links or open attachments unless you recognize the sender and know the content is safe. You don't often get email from steve.soroka@hilcorp.com. Learn why this is important AOGCC Industry Guidance Bulletin 10-01A Test Witness Notification AOGCC Industry Guidance Bulletin 10-02B Mechanical Integrity Testing Thanks and Regards, Chris Wallace, Sr. Petroleum Engineer, Alaska Oil and Gas Conservation Commission, 333 West 7th Avenue, Anchorage, AK 99501, (907) 793-1250 (phone), (907) 276-7542 (fax), chris.wallace@alaska.gov CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, contains information from the Alaska Oil and Gas Conservation Commission (AOGCC), State of Alaska and is for the sole use of the intended recipient(s). It may contain confidential and/or privileged information. The unauthorized review, use or disclosure of such information may violate state or federal law. If you are an unintended recipient of this e-mail, please delete it, without first saving or forwarding it, and, so that the AOGCC is aware of the mistake in sending it to you, contact Chris Wallace at 907-793-1250 or chris.wallace@alaska.gov. From: Stephen Soroka Sent: Wednesday, March 12, 2025 2:05 PM To: Wallace, Chris D (OGC) Cc: Regg, James B (OGC) ; Ryan Thompson ; Taylor Wellman ; Ryan Lewis Subject: Request to put Injector MPF-110 PTD #218022 online for AOGCC MIT-IA Mr. Wallace, PWI Injector MPF-110 (PTD #218022) was made Not Operable after failing an AGOCC MIT-IA on 5/18/24. Since then, a Tubing Tail plug was set, and an MIT-T Passed to 1622 psi on 6/7/24. On 3/11/25, an offline MIT-IA passed to 1854 psi. Hilcorp would like to place the well on injection to perform an AGOCC-witnessed MIT-IA after stabilization to see if there is an active leak when online and warm. Please respond at your earliest convenience. Steve Soroka Hilcorp Alaska LLC Field Well Integrity Steve.Soroka@hilcorp.com P: (907) 830-8976 The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are hereby notified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, please immediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently delete this message. While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that the onward transmission, opening, or use of this message and any attachments will not adversely affect its systems or data. No responsibility is accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate. The information contained in this email message is confidential and may be legally privileged and is intended only for the use of theindividual or entity named above. If you are not an intended recipient or if you have received this message in error, you are herebynotified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, pleaseimmediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently deletethis message. While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that theonward transmission, opening, or use of this message and any attachments will not adversely affect its systems or data. No responsibility is accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate. CAUTION: This email originated from outside the State of Alaska mail system. Do not click links or open attachments unless you recognize the sender and know the content is safe. You don't often get email from steve.soroka@hilcorp.com. Learn why this is important From:Wallace, Chris D (OGC) To:AOGCC Records (CED sponsored) Subject:FW: Request to put Injector MPF-110 PTD #218022 online for AOGCC MIT-IA Date:Wednesday, March 12, 2025 2:22:18 PM From: Wallace, Chris D (OGC) Sent: Wednesday, March 12, 2025 2:20 PM To: Stephen Soroka <Steve.Soroka@hilcorp.com> Cc: Regg, James B (OGC) <jim.regg@alaska.gov>; Ryan Thompson <Ryan.Thompson@hilcorp.com>; Taylor Wellman <twellman@hilcorp.com>; Ryan Lewis <Ryan.Lewis@hilcorp.com> Subject: RE: Request to put Injector MPF-110 PTD #218022 online for AOGCC MIT-IA Steve, Your request to put the well back online for monitoring and diagnostics including an AOGCC witnessed MITIA when stabilized is approved. AOGCC Industry Guidance Bulletin 10-01A Test Witness Notification AOGCC Industry Guidance Bulletin 10-02B Mechanical Integrity Testing Thanks and Regards, Chris Wallace, Sr. Petroleum Engineer, Alaska Oil and Gas Conservation Commission, 333 West 7th Avenue, Anchorage, AK 99501, (907) 793-1250 (phone), (907) 276-7542 (fax), chris.wallace@alaska.gov CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, contains information from the Alaska Oil and Gas Conservation Commission (AOGCC), State of Alaska and is for the sole use of the intended recipient(s). It may contain confidential and/or privileged information. The unauthorized review, use or disclosure of such information may violate state or federal law. If you are an unintended recipient of this e-mail, please delete it, without first saving or forwarding it, and, so that the AOGCC is aware of the mistake in sending it to you, contact Chris Wallace at 907-793-1250 or chris.wallace@alaska.gov. From: Stephen Soroka <Steve.Soroka@hilcorp.com> Sent: Wednesday, March 12, 2025 2:05 PM To: Wallace, Chris D (OGC) <chris.wallace@alaska.gov> Cc: Regg, James B (OGC) <jim.regg@alaska.gov>; Ryan Thompson <Ryan.Thompson@hilcorp.com>; Taylor Wellman <twellman@hilcorp.com>; Ryan Lewis <Ryan.Lewis@hilcorp.com> Subject: Request to put Injector MPF-110 PTD #218022 online for AOGCC MIT-IA Mr. Wallace, PWI Injector MPF-110 (PTD #218022) was made Not Operable after failing an AGOCC MIT-IA on 5/18/24. Since then, a Tubing Tail plug was set, and an MIT-T Passed to 1622 psi on 6/7/24. On 3/11/25, an offline MIT-IA passed to 1854 psi. Hilcorp would like to place the well on injection to perform an AGOCC-witnessed MIT-IA after stabilization to see if there is an active leak when online and warm. Please respond at your earliest convenience. Steve Soroka Hilcorp Alaska LLC Field Well Integrity Steve.Soroka@hilcorp.com P: (907) 830-8976 The information contained in this email message is confidential and may be legally privileged and is intended only for the use of theindividual or entity named above. If you are not an intended recipient or if you have received this message in error, you are herebynotified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, pleaseimmediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently deletethis message. While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that the onward transmission, opening, or use of this message and any attachments will not adversely affect its systems or data. No responsibilityis accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate. MEMORANDUM State of Alaska Alaska Oil and Gas Conservation Commission DATE:Monday, July 1, 2024 SUBJECT:Mechanical Integrity Tests TO: FROM:Austin McLeod P.I. Supervisor Petroleum Inspector NON-CONFIDENTIAL Hilcorp Alaska, LLC F-110 MILNE PT UNIT F-110 Jim Regg InspectorSrc: Reviewed By: P.I. Suprv Comm ________ JBR 07/01/2024 F-110 50-029-23599-00-00 218-022-0 W SPT 4036 2180220 1500 745 750 746 746 REQVAR F Austin McLeod 5/18/2024 Bump up from previous fail. AIO 10B.018. Two year. Monobore. S/I. 30 MinPretestInitial15 Min Well Name Type Test Notes: Interval P/F Well Permit Number: Type Inj TVD PTD Test psi API Well Number Inspector Name:MILNE PT UNIT F-110 Inspection Date: Tubing OA Packer Depth 1612 1737 1704 1680IA 744 45 Min 1658 60 Min Rel Insp Num: Insp Num:mitSAM240519180515 BBL Pumped:0.2 BBL Returned:1.6 Monday, July 1, 2024 Page 1 of 1             Resest failed on stabilization; total pressure loss > 2% see Insp Rpt # mitSAM240519180210 MEMORANDUM State of Alaska Alaska Oil and Gas Conservation Commission DATE:Monday, July 1, 2024 SUBJECT:Mechanical Integrity Tests TO: FROM:Austin McLeod P.I. Supervisor Petroleum Inspector NON-CONFIDENTIAL Hilcorp Alaska, LLC F-110 MILNE PT UNIT F-110 Jim Regg InspectorSrc: Reviewed By: P.I. Suprv Comm ________ JBR 07/01/2024 F-110 50-029-23599-00-00 218-022-0 W SPT 4036 2180220 1500 742 745 745 750 REQVAR F Austin McLeod 5/18/2024 AIO 10B.018. Two year. Monobore. Test bumped up. No bleed back. Bump up on separate report. 30 MinPretestInitial15 Min Well Name Type Test Notes: Interval P/F Well Permit Number: Type Inj TVD PTD Test psi API Well Number Inspector Name:MILNE PT UNIT F-110 Inspection Date: Tubing OA Packer Depth 775 1732 1674 1641IA 745 45 Min 1612 60 Min Rel Insp Num: Insp Num:mitSAM240519180210 BBL Pumped:1.9 BBL Returned: Monday, July 1, 2024 Page 1 of 1        (see Insp Rpt# mitSAM240519180515)  Test failed to stabilize; total loss > 2%   CAUTION: This email originated from outside the State of Alaska mail system. Do not click links or open attachments unless you recognize the sender and know the content is safe. From:Wallace, Chris D (OGC) To:AOGCC Records (CED sponsored) Subject:FW: MIT-IA for Milne Point well F-110 Date:Friday, May 24, 2024 3:36:26 PM Attachments:MIT MPU F-110 5-18-24 FAIL.xlsx From: Darci Horner - (C) <dhorner@hilcorp.com> Sent: Friday, May 24, 2024 3:29 PM To: Regg, James B (OGC) <jim.regg@alaska.gov>; Brooks, Phoebe L (OGC) <phoebe.brooks@alaska.gov>; Wallace, Chris D (OGC) <chris.wallace@alaska.gov> Cc: Ryan Thompson <Ryan.Thompson@hilcorp.com>; Taylor Wellman <twellman@hilcorp.com>; Alaska NS - Milne - Wells Foreman <AlaskaNS-WellsForeman@hilcorp.com>; Alaska NS - Milne - Wellsite Supervisors <AlaskaNS-Milne-WellsiteSupervisors@hilcorp.com>; Roger Allison <Roger.Allison@hilcorp.com>; Matthew Ross <Matthew.Ross@hilcorp.com>; Jess Hall <Jess.Hall@hilcorp.com>; Roger Allison <Roger.Allison@hilcorp.com>; Ryan Lewis <Ryan.Lewis@hilcorp.com>; Alaska NS - Milne - Field Operator Leads <AlaskaNS-Milne- FieldOperatorLeads@hilcorp.com> Subject: MIT-IA for Milne Point well F-110 All, Milne Point well F-110 (PTD # 2180220) failed an MIT-IA on May 24, 2024. The well has been classified as inoperable and a black lock has been installed. Please reach myself or Ryan Thompson (907-564-5280) with any questions. Regards, Darci Horner Technologist Office: (907) 777-8406 Cell: (907) 227-3036 Email: dhorner@hilcorp.com The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are herebynotified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, pleaseimmediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently deletethis message. While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that the onward transmission, opening, or use of this message and any attachments will not adversely affect its systems or data. No responsibility is accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate. Submit to: OPERATOR: FIELD / UNIT / PAD: DATE: OPERATOR REP: AOGCC REP: Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD 2180220 Type Inj W Tubing 742 745 745 750 745 Type Test P Packer TVD 4,027'BBL Pump 1.9 IA 775 1732 1674 1641 1612 Interval V Test psi 1500 BBL Return OA Result F Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD 2180220 Type Inj W Tubing 745 750 746 746 744 Type Test P Packer TVD 4,027'BBL Pump 0.2 IA 1612 1737 1704 1680 1658 Interval V Test psi 1500 BBL Return 1.6 OA Result F Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result Well Pressures:Pretest Initial 15 Min.30 Min.45 Min.60 Min. PTD Type Inj Tubing Type Test Packer TVD BBL Pump IA Interval Test psi BBL Return OA Result TYPE INJ Codes TYPE TEST Codes INTERVAL Codes Result Codes W = Water P = Pressure Test I = Initial Test P = Pass G = Gas O = Other (describe in Notes)4 = Four Year Cycle F = Fail S = Slurry V = Required by Variance I = Inconclusive I = Industrial Wastewater O = Other (describe in notes) N = Not Injecting Notes: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION Mechanical Integrity Test jim.regg@alaska.gov;AOGCC.Inspectors@alaska.gov;phoebe.brooks@alaska.gov chris.wallace@alaska.gov Notes: Notes: Notes: Hilcorp Alaska, LLC Milne Point / MPU / F Austin McLeod Derek Weglin 05/18/24 Notes:Monobore well, no OA. AIO 10B.018 requires MIT-IA every 2 years. Notes: Notes: Notes: F-110 F-110 Form 10-426 (Revised 01/2017)MIT MPU F-110 5-18-24 FAIL CAUTION: This email originated from outside the State of Alaska mail system. Do not click links or open attachments unless you recognize the sender and know the content is safe. From:Wallace, Chris D (OGC) To:AOGCC Records (CED sponsored) Subject:FW: NOT OPERABLE: MPF-110 (PTD# 2180220) - Failed MIT-IA Date:Tuesday, May 21, 2024 7:40:02 AM Attachments:MPF-110 90 day TIO plot.docx MPU F-110 schematic 5-16-22.pdf From: Ryan Thompson <Ryan.Thompson@hilcorp.com> Sent: Monday, May 20, 2024 2:17 PM To: Wallace, Chris D (OGC) <chris.wallace@alaska.gov>; Regg, James B (OGC) <jim.regg@alaska.gov> Cc: Taylor Wellman <twellman@hilcorp.com> Subject: NOT OPERABLE: MPF-110 (PTD# 2180220) - Failed MIT-IA Mr. Wallace, On 5/18/2024 PWI well MPF-110 failed an online state witnessed MIT-IA to 1732 psi. The well was shut in and freeze protected following the failing test. The well has operated under Administrative Approval since 6/2/2022, AIO 10B.018, for known Tubing x Inner Annulus communication. The well has been reclassified as Not Operable and will remain shut in until well barriers are restored. Attached is a well bore schematic and the 90 day TIO plot. Please respond with any questions. Thank you, Ryan Thompson Milne / Islands Well Integrity Engineer 907-564-5005 The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are hereby notified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, please immediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently delete this message. While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that the onward transmission, opening, or use of this message and any attachments will not adversely affect its systems or data. No responsibility is accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate. _____________________________________________________________________________________ CJD 4/9/2018 SCHEMATIC Milne Point Unit Well: MPU F-110 PTD: 218-022 API: 50-029-23599-00-00 TD = 11,550’(MD) / TD =4,029’(TVD) 20” KB Elev above MSL: 37.5’ 4-1/2” 2 9-5/8” 1 3/4 6 See ICD & Swell Packer Detail PBTD =11,545’ (MD) / PBTD =4,029’(TVD) 9-5/8” ‘ES’ Cementer @ 2,524’ 4-1/2” 5 CASING DETAIL Size Type Wt/ Grade/ Conn Drift ID Top Btm BPF 20" Conductor N/A / X-52 / Weld N/A Surface 107’ N/A 9-5/8" Surface 40 / L-80 / DWC/C 8.75” Surface 7,494’ 0.0758 4-1/2” Liner 13.5 / L-80 / Hyd 625 3.85” 7,322’ 11,550’ 0.0149 TUBING DETAIL 4-1/2" Tubing 12.6 / L-80 / TXP-SR 3.833” Surf 7,331’ 0.0152 JEWELRY DETAIL No Top MD Item ID Upper Completion 1 2,668’ X Nipple 3.813 2 6,339’ XN Nipple profile: 3.725” No Go / 3.813 Packing Bore 3 7,321’ 8.26” No-Go Locater on Tieback Assy ([4] - 1” Ported Seal Stem) 3.960 4 7,331’ Tieback Shoe 6.180 Lower Completion 4 7,322’ Liner Top Packer (TVD= 4,027’)- 5 11,545’ WIV (Ball on Seat/ Closed) PBTD - OPEN HOLE / CEMENT DETAIL 42" ~270 ft3 12-1/4"Stg 1 – 660 sx Lead / 400 sx Tail Stg 2 – 461 sx Lead / 270 sx Tail (258 bbl surface returns) 8-1/2” Cementless Injection Liner in 8-1/2” hole WELL INCLINATION DETAIL KOP @ 100’ Max Hole Angle = 94° @ 8,720’ MD TREE & WELLHEAD Tree Cameron 4 1/16" 5M w/ 4-1/16” 5M Cameron Wing Wellhead Cameron 11” 5K x sliplock bottom w/ (2) 2-1/16” 5K outs GENERAL WELL INFO API#: 50-029-23599-00-00 Completed by Innovation Depth MD Depth TVD ICD/Swell Packer Detail 7,602’ 4,054’ICD Halliburton (3) 0.125" / (0) 0.100" / (0) 0.075" Ports. SS ICD #7 - Hyd 521 12.6# 7,739’ 4,058’Swell Packer – Weatherford Genesis Swell Packer 8,053’ 4,063’ICD Halliburton (3) 0.125" / (0) 0.100" / (0) 0.075" Ports. SS ICD #6 - Hyd 521 12.6# 8,231’ 4,061’Swell Packer - Weatherford Genesis Swell Packer 8,668’ 4,063’ICD Halliburton (3) 0.125" / (0) 0.100" / (0) 0.075" Ports. SS ICD #5 - Hyd 521 12.6# 8,888’ 4,051’Swell Packer - Weatherford Genesis Swell Packer 9,118’ 4,043’ICD Halliburton (3) 0.125" / (0) 0.100" / (1) 0.075" Ports. SS ICD #4 - Hyd 521 12.6# 9,254’ 4,040’Swell Packer - Weatherford Genesis Swell Packer 10,104’ 4,024’ICD Halliburton (3) 0.125" / (0) 0.100" / (1) 0.075" Ports. SS ICD #3 - Hyd 521 12.6# 10,572’ 4,032’Swell Packer - Weatherford Genesis Swell Packer 10,720’ 4,035’ICD Halliburton (3) 0.125" / (1) 0.100" / (1) 0.075" Ports. SS ICD #2 - Hyd 521 12.6# 10,979’ 4,035’Swell Packer - Weatherford Genesis Swell Packer 11,409’ 4,031’ICD Weatherford (5) 0.125' Ports SS ICD #1 - Hyd 625 13# Box X Pin. MCX w/ .5"bean and equilizing sub install 5/06/2022 MEMORANDUM State of Alaska Alaska Oil and Gas Conservation Commission DATE:Friday, June 10, 2022 SUBJECT:Mechanical Integrity Tests TO: FROM:Guy Cook P.I. Supervisor Petroleum Inspector NON-CONFIDENTIAL Hilcorp Alaska, LLC F-110 MILNE PT UNIT F-110 Jim Regg InspectorSrc: Reviewed By: P.I. Suprv Comm ________ JBR 06/10/2022 F-110 50-029-23599-00-00 218-022-0 W SPT 4036 2180220 1500 757 760 757 757 OTHER P Guy Cook 5/10/2022 Seeking an AA for water injection only. Testing completed with a Little Red Services pump truck and calibrated gauges. 30 MinPretestInitial15 Min Well Name Type Test Notes: Interval P/F Well Permit Number: Type Inj TVD PTD Test psi API Well Number Inspector Name:MILNE PT UNIT F-110 Inspection Date: Tubing OA Packer Depth 32 1753 1683 1655IA 45 Min 60 Min Rel Insp Num: Insp Num:mitGDC220509164646 BBL Pumped:3 BBL Returned:3 Friday, June 10, 2022 Page 1 of 1 9 9 9 9 9 9 9 9 9 9 James B. Regg Digitally signed by James B. Regg Date: 2022.06.10 14:56:11 -08'00' CAUTION: This email originated from outside the State of Alaska mail system. Do not click links or open attachments unless you recognize the sender and know the content is safe. From:Wallace, Chris D (OGC) To:AOGCC Records (CED sponsored) Subject:FW: UNDER EVALUTATION: Produced Water Injector MPF-110 (PTD# 218-022) Date:Tuesday, May 17, 2022 11:28:49 AM Attachments:image001.png image002.png From: Jerimiah Galloway <Jerimiah.Galloway@hilcorp.com> Sent: Monday, May 16, 2022 3:22 PM To: Taylor Wellman <twellman@hilcorp.com>; William Kruskie <wkruskie@hilcorp.com>; Mark O'Malley <momalley@hilcorp.com>; Sean Haynes <shaynes@hilcorp.com>; Nick Fortney <nfortney@hilcorp.com>; Michael Wilkerson <mwilkerson@hilcorp.com>; Derek Weglin <Derek.Weglin@hilcorp.com>; Josh McNeal <jmcneal@hilcorp.com>; David Haakinson <dhaakinson@hilcorp.com>; Oliver Sternicki <Oliver.Sternicki@hilcorp.com>; Alaska IMS User <akimsuser@hilcorp.com>; Darci Horner - (C) <dhorner@hilcorp.com>; Nathan Williams <Nathan.Williams@hilcorp.com>; Jeffrey Jones - (C) <jjones@hilcorp.com> Cc: Wallace, Chris D (OGC) <chris.wallace@alaska.gov> Subject: RE: UNDER EVALUTATION: Produced Water Injector MPF-110 (PTD# 218-022) All, Per conversation with Chris Wallace, we are good to leave this well on injection until the AA is final. I will keep it on the Under Evaluation list for now and will update as soon as we get final approval back. Please let me know if you have any questions or concerns. Jerimiah Jerimiah Galloway MPU/Islands Well Integrity Engineer Email: jerimiah.galloway@hilcorp.com O: (907)564-5005 C: (828)553-2537 From: Jerimiah Galloway Sent: Monday, April 18, 2022 9:08 AM To: Taylor Wellman <twellman@hilcorp.com>; William Kruskie <wkruskie@hilcorp.com>; Mark O'Malley <momalley@hilcorp.com>; Sean Haynes <shaynes@hilcorp.com>; Nick Fortney <nfortney@hilcorp.com>; Michael Wilkerson <mwilkerson@hilcorp.com>; Derek Weglin <Derek.Weglin@hilcorp.com>; Josh McNeal <jmcneal@hilcorp.com>; David Haakinson <dhaakinson@hilcorp.com>; Oliver Sternicki <Oliver.Sternicki@hilcorp.com>; Alaska IMS User <akimsuser@hilcorp.com>; Darci Horner - (C) <dhorner@hilcorp.com>; Nathan Williams <Nathan.Williams@hilcorp.com>; Jeffrey Jones - (C) <jjones@hilcorp.com> Subject: FW: UNDER EVALUTATION: Produced Water Injector MPF-110 (PTD# 218-022) All, F-110 is now UNDER EVAL. Let’s move forward with an internal MIT-IA and discuss before we call the state out. MIT-IA Max pressure 2750 psi Target pressure 2500 psi Please let me know if you have any questions. Jerimiah Jerimiah Galloway MPU/Islands Well Integrity Engineer Email: jerimiah.galloway@hilcorp.com O: (907)564-5005 C: (828)553-2537 From: Jerimiah Galloway Sent: Monday, April 18, 2022 9:06 AM To: 'Wallace, Chris D (DOA)' <chris.wallace@alaska.gov> Cc: Regg, James B (CED) <jim.regg@alaska.gov>; David Haakinson <dhaakinson@hilcorp.com> Subject: UNDER EVALUTATION: Produced Water Injector MPF-110 (PTD# 218-022) Mr. Wallace, Produced Water Injector MPF-110 (PTD# 218-022) passed a witnessed MIT-IA to 1701 psi on 04/08/2022. Afterwards the inner annulus pressure saw a pressure increase which initially appeared to be thermally related and was bled. Inner annulus pressure has continued to show repressurization post bleed. The well is now classified as UNDER EVALUATION and is placed on a 28 day clock for further evaluation and diagnostics. Plan Forward: 1. PPPOT-T – Complete, Passed to 5000 psi 2. MIT-IA 3. AOGCC Witness MIT-IA (Pending) 4. Eng to evaluate further diagnostics/repair or AA Jerimiah Galloway MPU/Islands Well Integrity Engineer Email: jerimiah.galloway@hilcorp.com O: (907)564-5005 C: (828)553-2537 The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are hereby notified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, please immediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently delete this message. While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that the onward transmission, opening, or use of this message and any attachments will not adversely affect its systems or data. No responsibility is accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate. Kaitlyn Barcelona Hilcorp North Slope, LLC GeoTechnician 3800 Centerpoint Drive, Suite 1400 Anchorage, AK 99503 Tele: 907 564-4389 E-mail: kaitlyn.barcelona@hilcorp.com Please acknowledge receipt by signing and returning one copy of this transmittal Received By: Date: DATE: 5/10/2022 To: Alaska Oil & Gas Conservation Commission Natural Resource Technician 333 W 7th Ave Suite 100 Anchorage, AK 99501 DATA TRANSMITTAL MPU F-110 (PTD 218-022) Leak Point Survey 05/05/2022 Please include current contact information if different from above. PTD:218-022 T36591 Kayla Junke Digitally signed by Kayla Junke Date: 2022.05.11 10:03:11 -08'00' CAUTION: This email originated from outside the State of Alaska mail system. Do not click links or open attachments unless you recognize the sender and know the content is safe. From:Wallace, Chris D (OGC) To:AOGCC Records (CED sponsored) Subject:FW: UNDER EVALUTATION: Produced Water Injector MPF-110 (PTD# 218-022) Date:Monday, April 18, 2022 10:52:46 AM Attachments:image001.png image002.png From: Jerimiah Galloway <Jerimiah.Galloway@hilcorp.com> Sent: Monday, April 18, 2022 9:06 AM To: Wallace, Chris D (OGC) <chris.wallace@alaska.gov> Cc: Regg, James B (OGC) <jim.regg@alaska.gov>; David Haakinson <dhaakinson@hilcorp.com> Subject: UNDER EVALUTATION: Produced Water Injector MPF-110 (PTD# 218-022) Mr. Wallace, Produced Water Injector MPF-110 (PTD# 218-022) passed a witnessed MIT-IA to 1701 psi on 04/08/2022. Afterwards the inner annulus pressure saw a pressure increase which initially appeared to be thermally related and was bled. Inner annulus pressure has continued to show repressurization post bleed. The well is now classified as UNDER EVALUATION and is placed on a 28 day clock for further evaluation and diagnostics. Plan Forward: 1. PPPOT-T – Complete, Passed to 5000 psi 2. MIT-IA 3. AOGCC Witness MIT-IA (Pending) 4. Eng to evaluate further diagnostics/repair or AA Jerimiah Galloway MPU/Islands Well Integrity Engineer Email: jerimiah.galloway@hilcorp.com O: (907)564-5005 C: (828)553-2537 The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received thismessage in error, you are hereby notified that any dissemination, distribution, or copy of this email is strictly prohibited. If you have received this email in error, please immediately notify us by return email or telephone if the sender'sphone number is listed above, then promptly and permanently delete this message. While all reasonable care has been taken to avoid the transmission of viruses, it is the responsibility of the recipient to ensure that the onward transmission, opening, or use of this message and any attachments will not adversely affectits systems or data. No responsibility is accepted by the company in this regard and the recipient should carry out such virus and other checks as it considers appropriate.