Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAbout198-164 Pages NOT Scanned in this Well History File
XHVZE
This page identifies those items that were not scanned during the initial scanning project.
They are available in the original file and viewable by direct inspection.
/¢<~.../~/,(y/ File Number of Well History File
PAGES TO DELETE Complete
RESCAN
[] Color items - Pages:
~ Grayscale, halftones, pictures, graphs, charts -
Pages:
[] Poor Quality Original - Pages:
[] Other- Pages:
DIGITAL DATA
[] Diskettes, No.
[] Other, No/Type
OVERSIZED
E] Logs of various kinds
r~ Other
COMMENTS:
Scanned b~ildred Damth;'/Natb. ah Lowell
TO RE-SCAN
Notes:
/si
Re-Scanned by: Beverly Mildred Damtha~lathan ~_owell Date: Is'
MICROFILMED
7~30~02
DO NOT PLACE
ANY NEW MATERIAL
UNDER THIS PAGE
Saved as M:/weepie/microfilm marker.doc
~KA OIL AND GAS
CONSERVATION COMPlISSION
TONY KNOWLES, GOVERNOR
333 W. 7TM AVENUE, SUITE 100
ANCHORAGE, ALASKA 99501-3539
PHONE (907) 279-1433
FAX (907) 276-7542
Fritz Gunkel, Manager Drilling
BP Exploration (Alaska) Inc.
PO Box 196612
Anchorage AK 99519
Re: Cancelled or Expired PTD's.
Dear Gunkel:
September 6, 2001
The Alaska Oil and Gas Conservation Commission ("AOGCC") approved the following
referenced permit to drills. The AOGCC has a long-standing policy of releasing
cancelled or expired permits two years from the date the application was approved by the
AoGcc.
The following files are scheduled to be released October 1, 2001.
Permit to Drill No.'s:
97-047 98-019 99-002
97-056 98-050 99-009
97-082 98-135
..,
97-090 98-154
97-100 98-155
97-121 98-164
...
97-159 98-167
97-191 98-177
..
98-210
98-211
--
98-223
98-236
98-257
98-261
Sincerely,
Executive Secretary
Memorandum
State of Alaska
Oil and Gas Conservation Commission
To: Well File 198-164
DATE August 31, 2000
Re: Expired Permit Action
WELL: Prudhoe Bay Unit 07-07BXX API# 50- 029-20901-95
This memo will remain at the front of the subject well file.
Our adopted conventions for assigning APl numbers, permit numbers and well names did not
specifically address expired or cancelled permits. This omission has caused some inconsistencies in
the treatment of these kinds of applications for permit to drill. Operators have asked us to adopt formal
procedures for this class of permit application in order to prevent future database disparities.
If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain
unchanged. The APl number and in some instances the well name reflect the number of preexisting
redrills and or multilaterals in a well. In order to prevent confusing a cancelled or expired permit with
an active well or multilateral these case sensitive well identifiers will be changed for expired and
cancelled applications for permits to drill.
The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is -95.
The well number for a cancelled or expired permit is modified with an appended XX.
CANCELED PERMITS ARE RELEASABLE 2 years from the date on the letter received from the
operator requesting the permit canceled.. (Memorandum January 23, 1997 by Dave Johnston,
subject: Canceled and Expired Permits)
EXPIRED PERMITS ARE RELEASABLE 2 years from the date on the application was issued by
the commission, unless the operator ask for extended confidentiality.
AOGCC database has been changed to reflect these changes to this permit.
Statistical TechniCian
TONY KNOWLE$, GOVERNOR
ALASKA OIL AND GAS
CONSERVATION COMMISSION
3001 PORCUPINE DRIVE
ANCHORAGE, ALASKA 99501-3192
PHONE: (907) 279-1433
FAX: (907) 276-7542
August 31, 1998
Erin Oba
Engineering Supervisor
ARCO Alaska Inc.
P O Box 100360
Anchorage, AK 99510-0360
Re;
Prudhoe Bav Unit 7-07B
ARCO Alaska Inc.
Permit No. 98-164
Sur. Loc. 1347'SNL, 138"WEL, Sec. 33, T11N, R14E, UM
Btmnhole Loc. 5206'FNL, 387'FEL, Sec. 27, T11N, R14E, UM
Dear Ms Oba:
Enclosed is the approved application for permit to redrill the above referenced well.
The permit to redrill does not exempt you from obtaining additional permits required by law from
other governmental agencies, and does not authorize conducting drilling operations until all other
required permitting determinations are made.
Blowout prevention equipment (BOPE) must be tested in accordance with 20 AAC 25 035.
Sufficient notice (approximately 24 hours) must be given to allow a representative of the
Commission to witness a test of BOPE installed prior to drilling new hole. Notice may be given
by contacting the Commission petroleum field inspector on the North Slope pager at 659-3607.
·
Chairman
BY ORDER OF THE COMMISSION
dlffEnclosures
CCi
Department of Fish & Gmne, Habitat Section w/o encl.
Department of Environmental Conservation w/o encl.
-" -- RECEIVED
STATE OF ALASKA "
ALASKA OIL AND GAS CONSERVATION COMMISSION
PERMIT TO DRILL AUO 12 1998
20 AAC 25.005
la. Type of Work Drill_ Redrill ~ I lb. Type of Well Exploratory. Strati~!
...... ~e_.v_empment Oil _~X
Re-Entry__ Deepen -I Service_ Development Gas_ Single Zone ~ ~llUItUl~f~E~l~ple Zone_
2. Name of Operator 5.Datum Elevation (DF or KB) 10. Field and Pool
ARCO Alaska, Inc. RKB 70'
3. Address 6. Property Designation
P.O. Box 100360 Prudhoe Bay Field
Anchorage, AK 99510-0360 ADL 028309 Prudhoe Bay Oil Pool
4. Location of well at surface 7. Unit or property Name 11. Type Bond (see 20 AAC 25.025)
1347' SNL, 138' WEL, Sec 33, T11N, R14E, UM
Prudhoe Bay Unit Statewide
At top of productive interval 8. Well number Number
963' NSL, 3788' EWL, Sec 27, T11N, R14E, UM 7-07B #U-630610
At total depth 9. Approximate spud date Amount
(Proposed)
5206' FNL, 387' FEL, Sec 27, T11N, R14E, UM September, 1998 $200,000
12. Distance to nearest I 13. Distance to nearest well 14. Number of acres in property 15. Proposed depth (MD and TVD)
property line
No Close Approach 12079' MD / 8994' TVD
16. To be completed for deviated wells 17. Anticipated pressure (see 20 AAC 25.035(e)(2))
kickoff depth 10580' MD Maximum hole an~lle 97° Maximum surface 2500 psi,g At total depth (3'VD) 3379 psig @ 8800'
18. Casing program I Setting Depth
Size Specification Top Bottom Quantity of cement
Hole Casing Weight Grade Coupling Length MD TVD MD TVD (include stage data)
3-3/4" 3-3/16" 6.2 L-80 TC II 2459' 9620' 8128' 12079' 8994' 15 bbls
OR' "N
19. To be completed for Redr,l,, Re-entry, and Deepen Operations. I L~I ~ L
Present well condition summary
Total depth: measured 10950 feet Plugs(measured) Bottom tagged @ 10796' MD (7/03/97)
true vertical 9106 feet
Effective depth: measured 10796 feet Junk (measured)
true vertical 8999 feet
Casing Length Size Cemented Measured depth True Vertical depth
Conductor 110' 20" 470 Sx Arcticset II 80' 80'
Surface 2426' 13-3/8" 1600 Sx Fondu & 2496' 2496'
400 Sx PFC
Production 9853' 9-5/8" 500 Sx Class G & 50 bbls PFC 9923' 8331'
Liner 1324' 7" 400 Sx Class G 10945' 9102'
Perforation depth: measured 10638' - 10646'; 10723' - 10740'; 10756' - 10766'; 10772' - 10788'; 10802'- 10807'; 10810' - 10825';
10829' - 10838'.
true vertical 8860' - 8866'; 8927' - 8940'; 8953' - 8961'; 8966' - 8978'; 8989' - 8993'; 8996' - 9008'; 9011' - 9018'.
20. Attachments Filing fee ~ Property plat _ BOP Sketch _X Diverter Sketch _ Drilling program __x
Drilling fluid program __ Time vs depth pict _ Refraction analysis Seabed report -- 20 AAC 25.050 requirements _
21. I hereb,,v~rtifyth.at.,~oregoing is true and correct to the best of my knowledge Questions: Call Steve Ward @ 265-1305.
SignedV/,~/4~~ '~/ ~'~i/~('") Titlle En,cjineeringSupervisor Date
Commission Use Only Preparecfby Paul Rauf 263-4990
P e r m~l~c~m 'b,,~'~' "~"" I APl number
o,I ApPr°va'date~%~'//'f:L¢'¢ I See cover letter for
· - -- '" other requirements
Conditions of approval Samples required Yes "~No Mud Icg required _ Yes
Hydrogen sulfide measures ~Yes _ No Directional survey required .~Yes _ No
Required working pressure for DOPE _ 2M; _ 3M; _ 5M; _ 10M; _ 15M _'fk~500 psi for CTU
Other:
Original
David W. Johnston by order of
Approved by Commissioner the commission Date
Form 10-401 Rev. 7-24-89 Submit in Iriplicate
DS 7-7B
CT Sidetrack and Completion
Intended Procedure
Objective:
Set whipstock. Plugback existing wellbore. Directionally drill a horizontal well
from the existing wellbore. Complete with 3-3/16"cemented liner. Perforate
and produce.
Intended Procedure:
Set top of whipstock @ - 10575'. Cement squeeze the current
perforations and leave cement @ -- 10585' md.
NU BOPE and test. Mill window in 7" casing at ~-10580' md. Drill 10' of
formation and perform Leak off test to 9.4 ppg, 0.5 ppg above the highest
anticipated mud weight (8.9 ppg FloPro).
Directionally drill 4" x -1200' horizontal well to access Lower Romeo
reserves.
· Run 3-3/16" cemented liner to TD.
Perforate and return well to production.
Augustll, 1998
8500
8600
8700
8800
8900
I~ 9o00
I
9100
ANCO Alaska, Inc.
Structure : D.S. 7
Field : Prudhoe Bay
Well : 7-07a
Location : North Slope, Alaska
Created by planner
Dote plotted : lO-Aug-98
Plot Reference is 7-078 CT Sidetrack.
Coordinates ore in feet reference 7-07.
True Vertical Depths are reference Mean Sea Level.
--- Baker Hughes INTEQ ---
East (feet) ->
3900 4000 41 O0 4200 4300 4400 4500 4600 4700 4800 4900 5000 51 O0 5200 5300 5400
I I I I I I I I t I I I I I I I I I I I I I I I I I I I I I
Kick off Point
Tie on - 8696.50 Tvd, 2323.55 N, 4164.58 E
7-07bhs
7-07ihs
ie on - 39.16 Inc, 10500.00 Md, 8696.50 Tvd, 1202.89 Vs
4 5 6
7 07bhs 7-07ihs 7-07ohs
T.D. & End of Build/Turn - 96.84 Inc, 12078.85 Md, 8924.00 Tvd, 2452.06 Vs
7-07ohs
T.D. & End of Build - 8924.00 Tvd, 1421.00 N, 5028.00 E
I I I I I I I I I I I I I I I I I I I I I I I II I I I I I I I I I I I
~00 11 O0 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800
Vertical Section (feet) ->
Azimuth 156.25 with reference 0.00 N, 0.00 W from 7-07
2500
2400
2300
2200
2100
2000
1900
1800
1700
1600
1500
1400
1300
1200
1100
ARCO Alaska, Inc.
D.S. 7,7-07
Prudhoe Bay, North Slope, Ataska
Heasured Inc[in. Azimuth True Vert
Depth Degrees Degrees Depth
10500.00 39.16 73.03 8696.50
10580.00 38.54 73.36 8758.80
10600.00 42.03 70.34 8774.06
10695.87 59.50 60.00 8834.56
10700.00 59.76 60.91 8836.64
10800.00 67.74 81.49 8881.23
10900.00 77.99 99.57 8910.88
10999.00 89.19 116.11 8922.00
11000.00 89.t7 116.31 8922.01
11100.00 87.83 136.27 8924.66
11168.70 87.05 150.00 8927.74
11200.00 87.20 150.97 8929.31
11300.00 87.69 154.07 8933.76
11400.00 88.19 157.17 8937.35
11500,00 88.69 160,27 8940.07
11600.00 89.20 163.37 8941.91
11700.00 89.71 166.46 8942.86
11768.36 90.06 168.58 8943.00
11800.00 90.77 165.89 8942.77
11900.00 93.02 157.37 8939.45
12000.00 95.20 148.82 8932.27
12078.85 96.84 142.03 8924.00
RECTANGULAR
COORDINATES
2323.55 N 4164.38 E
2338.06 N 4212.42 E
2342.10 N 4224.70 E
2373.85 N 4291.32 E
2375.60 N 4294.42 E
2403.74 N 4378.79 E
2402.44 N 4473.75 E
2372.31 N 4566.87 E
2371.87 N 4567.77 E
2313.01 N 4647.94 E
2258.24 N 4689.02 E
2231.03 N 4704.42 E
2142.41 N 4750.51 E
2051.40 N 4791.75 E
1958.26 N 4828.02 E
1863.28 N 4859.21 E
1766.74 N 4885.23 E
1700.00 N 4900.00 E
1669.15 N 4906.99 E
1574.39 N 4938.45 E
1485.53 N 4983.54 E
1421.00 N 5028.00 E
PROPOSAL LISTING Page 1
Your ref : 7-07B CT Sidetrack
Last revised : lO-Aug-98
Dogleg Vert Tool
Deg/lOOft Sect Face
0.00 1202.89 161
0.82 1225.64 -30
20.00 1231.22 -28
20.00 1254.38 71
20.06 1255.25 71
20.06 1293.30 62
20.06 1359.92 56
20.06 1446.10 94
20.00 1447.04 94
20.00 1545.01 93
20.00 1612.98 81
3.14 1643.27 81
3.14 1739.15 80
3.14 1833.40 80
3.14 1925.75 80
3.14 2015.92 80
3.14 2103.63 80
3.14 2162.04 -75
8.80 2189.16 -75
8.80 2279.35 -75
8.80 2374.71 -76
8.80 2452.06 N/A
C T Drilling Wellhead Detail
~ CT Injector Head
~ Stuffing Box (Pack-Off), 10,000 psi Working Pressure
Methanol Injection ,~ I- 7'' Riser
I I
Otis 7" WLA Quick
Connect
I I
Annular BOP (Hydril),7-1/16" ID
5,000 psi working pressure
I I
Alignment Guide Flange _ ~
t= "
7-1/16;',Gate5M RamBOPEType Dual ~, ,~ ~
Fire Resistant ~
Flanged
Kelly Hose to Dual HCR Man
rial Vah
Choke Manifold
;-~.5") ..
~ ~utters or
' '--I Combination Cutter/Blinds
Slip/ Pipe rams
Manual Valves Drilling spool 7-1/16", 5M
by 7-1/16", 5M
Ram Type Dual Gate BO..~.PE 2" Pump-In
Hydraulic over Electric
7-1/16" ID with ~
Pipe/Slip Rams
Manual Master Valve
0.458' (5.5")
Hanger
Fire resistant Kelly Hose to
Flange by Hammer up 1/4 Turn
Valve on DS Hardline to Standpipe
manifold
9-5/8" Annulus
13-3/8" Annulus
R:I G
Alaska
LAYOUT
DS 7-7B Proposed CT
Sidetrack Horizontal
5-1/2" Tubing
Packer @ 9581'
7" Liner Top~
9621'
4-1/2" DB-6 Nipple
@ 9652'
Cement top in 7" 9800'
5-1/2" Camco Bal-O
Nipple @ 2130'
/2" Camco MMG
GLM's
9-5/8" Casing
shoe @ 9923'
Top of 3-3/16"
Liner in TT
Initial Perfs
7"Casing Shoe @ 10947'
Window cut in 7" at
~ 10580' - 10585'
4" Open hole
Current perforations
cement squeezed
3-3/16" liner
TD @ -,
12080'
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
APPLICATION FOR SUNDRY APPROVALS
1. Type of ~queat
Change a,Ol~OVed pro.am _
Abandon _X ,Suspe~3 _ Operaioa Shutdovm _
R .epair well_ Rugging _X '13me extension _
Pull lubing_ Variance_ Perforate_
Reenter s~spended we~l _
SlJmulate _
Oher _
2. Name of Operator.
ARCO Alaska, Inc.
3. Address:
P.O. Box 100360
Anchorage, AK 99510-0360
4. Location otwell at surface:
1347' SNL, 138' WEL, Sec 33, T11N, R14E, UM
At top of productive interval:
963' NSL, 3788' EWL, Sec 27. T11N, R14E, UM
At effective depth:
At total depth:
1128' NSL, 4267' EWE Sec 27, T11N, R14E, UM
12. Present well condition summary
Total Depth: measured 10950 feet
t.rue vertical 9106 feet
t5. Type of Well:
D~empment_X
Explo~al~y _
S~atagra~xc _
Selene _
6. Datum of eiavation ~DF or KB feet):
7O' RKB
'7. Unit or Property:
Prudhoe Bay Unit
8. Well nurrber:.
07-07A
9. Permit nurr~er.
83-13
10. APl number,
50-029-20901
1. Fie~d/Pool:
Prudhoe Bay Oil Pool
Plugs (measured) Bottom tagged @ 10796' MD (7/03/97)
Effective Depth: measured 10796 feet Junk (measured)
true ve~cal 8999 feet
'"~
Casing Length
Size Cemented Measured depth True vertical depth
Conductor 80'
Surface 2426'
Production 9853'
Liner 1324'
20" 470 Sx Arcticset II 80' 80'
13-3/8" toDD Sx Fondu & 400 2496' 2496'
4O0 Sx PFC
9-5/8" 500 Sx Class G & 9923' 8331'
50 bbls PFC
7' 400 Sx Class G 10945' 9102'
Perforation Depth
measured 10638'-10646'; 10723'-10740'; 10756'-10766'; 10772'-10788'; 10802'- 10807'; 10810'-10825'; 10829'-10838'.
true vertical 8860'- 8866'; 8927' - 8940'; 8953' - 8961'; 8966' - 8978'; 8989' - 8993'; 8996'- 9008'; 9011'- 9018'.
Tubing (size, grade, and measured depth) 5-1/'2", 17#, L-80, POT ~ 959Z MD; 4-1.r2", 12.6~, L-80, PCT ~9664' MD.
Packers and SSSV (type and measured depth) Baker 8AB Packer @ 9581' MD; 5-1/2" Camco Bal-O SSSV @ 2130' MD.
DUPLICATE
13. Atlachments
Description summary d proposal _X Detailed operations program _ BOP sketch _X
14. Estimated date for commencing operation 115. Status of well classification as:
I Oil_X Gas _
I Service
September, 1998
16. If proposalwas verbally approved
Name of approver . Date approved
17. I hereby certity thatT//going ~s/~/con'ect to the best of my knowledge.
Title: Engineering SupeMsor
Suspended _
Questions: Call Steve Ward at 265.1305.
FOR COMMISSION USE ONLY Prepared by Pau/Rauf263*~90
Conditions of approval: Notify tom.ion so representitive may witness
Plug integrety_ BOP test _ Loca~n clearance _
Mechanical integrety test _ Subsequent form required 10- ~
,~proved by order of the Commissioner
David W. Johnston
Commissioner
Form 10-403 Rev 06/15188 SUBMIT IN TRIPUCATE
· WELL PERMIT CHECKLIST
FIELD & POOL
ADMINISTRATION
COMPANY
INIT CLASS ~ //"',c>~! GEOL
ENGINEERING
D~TE
WELL NAME
1. Permit fee attached .......................
2. Lease number appropriate ...................
3. Unique well name and number ..................
4. Well located in a defined pool ..................
5. Well located proper distance from drilling unit boundary ....
6. Well located proper distance from other wells ..........
7. Sufficient acreage available in drilling unit ............
8. If deviated, is wellbore plat included ...............
9. Operator only affected party ...................
10. Operator has appropriate bond in force .............
11. Permit can be issued without conservation order ........
12. Permit can be issued without administrative approval ......
13. Can permit be approved before 15-day wait ...........
AREA
UNIT# ./'//~,~
PROGRAM: exp [] dev~ redrll~ serv [] wellbore seg El ann. disposal para req
ON/OFF SHORE
N
N
N
N
~N
N
(~)N
14. Conductor string provided ...................
15. Surface casing protects all known USDWs ...........
16. CMT vol adequate to circulate on conductor & surf csg .....
17. CMT vol adequate to tie-in long string to surf csg ........
18. CMT will cover all known productive horizons ..........
19. Casing designs adequate for C, T, B & permafrost .......
20. Adequate tankage or reserve pit .................
21. If a re-drill, has a 10-403 for abandonment been approved...
22. Adequate we,bore separation proposed .............
23. If diverter required, does it meet regulations ..........
24. Drilling fluid program schematic & equip list adequate .....
25. BOPEs, do they meet regulation ................
26. BOPE press rating appropriate; test to ~.5"'OCD psig.
27. Choke manifold complies w/APl RP-53 (May 84) ........
GEOLOGY
TE
28. Work will occur without operation shutdown ........... (:~ N
29. Is presence of H2S gas probable ................. (Y.) N
30. Permit can be issued w/o hydrogen sulfide measures .....
31. Data presented on potential overpressure zones .......
32. Seismic analysis .of shallow gas zones .............
33. Seabed condition survey (if off-shore) .............
34. Contact name/phone for weekly progress repods ...... ./// Y N
[exploratory only]
ANNULAR DISPOSAL 35.
APPR DATE
With proper cementing records, this plan
(A) will contain waste in a suitable receiving zone_; .......
(B) will not contaminate freshwater; or causing waste...
to surface; ~
(C) will not impair mechani~grity of the well used for disposal;
(D) will not damage pr.R~ng formation or impair recovery from a
pool; and
(E) will not circumvent 20 AAC 25.252 or 20 AAC 25.412.
Y N
Y N tO)A-' fi.bl ,IP-..6~U(:.,5"¢¢,~.~
Y N
Y N
Y N
GEOLDGY: ENGINEERING: UIC/Annular COMMISSION:
RNC ,
co ~ ~/~ -
Comments/Instructions:
M:chel~list rev 05~29~98
dlf, C:\msoffir.:r;\wordiart\dinua\chr~cMi,'-;t