Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU FS2 - BP and Hilcorp %43Jessie L. ChmielowskiDigitally signed by Jessie L. Chmielowski Date: 2021.09.16 07:47:09 -08'00' 2. Facility NamePBU FS 2Percent99.43%0.57%MCF19. Remarks:(346) 237-2244 Date 8/17/2020I hereby certify that the foregoing is true and correct to the best of my knowledge.SignatureTitleProduction Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235.Printed NameTommy HoangPhoneDateMCF15. NGL Gas Equivalent0ConservationMCF16. Purchased gas0Waste:17. Transferred from: CGF215,37618. Transferred to: (Express as a negative #) CGF-23,979,683Commissioner13. Other (see instructions)0Official Use OnlyAuthorization >1 hr:SafetyMCF14. TOTAL VOLUME (ITEMS 6-12)660,191Lease Use12. Fuel gas used in lease operations.636,69710. Pilot and Purge12,84411. Assist Gas09. Flared or vented more than 1 hour (see instr.)4,400PUT RIVER C&W LOBE 6401818. Flared or vented 1 hour or less6,2500290000029 PBU - EOA HILCORP July-2020Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionTTommy HoangForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate'65Jessie L. ChmielowskiDigitally signed by Jessie L. Chmielowski Date: 2021.09.16 08:00:53 -08'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTJuly 2020Unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hrNot required for events <= 1 hr7/12/20201254-13043,1257/15/20201632-16423,125TOTAL6,250Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee AttachmentsSee AttachmentsTOTAL0Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hrNot required for events <= 1 hrTOTAL0Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE7/31/20201030-15304,400See AttachmentsSee AttachmentsTOTAL4,400 TOTALUnplanned Events < 1 Hour6,250Unplanned Events > 1 Hour0Planned Events < 1 hour and not0exceeding 5,000 MCFPlanned Events > 1 hour or4,400exceeding 5,000 MCFPilot Purge12,844Assist0TOTAL FLARED VOLUME23,494 Flare Start Date 07/01/2020 Flare End Date 07/31/2020 FS2 Flare Report Total Volume (MSCF) 4400 Report Number System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 20-142 Controlled Blowdown 07/31/2020 10:30:00 am 3:30:00 pm 300 min No No Yes HEC- HOU\JO4497 4400 Plant shutdown for maintenance. Determination Cause Completed plant de-pressure Action Taken Daily Volume (MSCF) 4400 Total Volume (MSCF) 4400 Generated 08/03/2020 10:00:27AM Page 4 of 7 2. Facility NamePBU FS 2Percent100.00%MCF19. Remarks:-20,907,825Commissioner(346) 237-2244 Date 9/17/2020I hereby certify that the foregoing is true and correct to the best of my knowledge.SignatureTommy HoangTitleProduction AnalystNote: All volumes must be correctedto pressure of 14.65 psia and to atemperature of 60o F. Authority 20AAC25.235.Printed NameTommy HoangPhone12. Fuel gas used in lease operations.574,182DateMCF15. NGL Gas Equivalent0ConservationMCF16. Purchased gas0Waste:17. Transferred from: CGF199,79018. Transferred to: (Express as a negative #) CGF13. Other (see instructions)0Official Use OnlyAuthorization >1 hr:SafetyMCF14. TOTAL VOLUME (ITEMS 6-12)588,005Lease Use11. Assist Gas1789. Flared or vented more than 1 hour (see instr.)17810. Pilot and Purge13,4678. Flared or vented 1 hour or less00290000029 PBU - EOA BP August-2020Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate'65Jessie L. ChmielowskiDigitally signed by Jessie L. Chmielowski Date: 2021.09.16 08:05:46 -08'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTAugust 2020Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE8/3/2020 1700-2030 178 See Attachments See AttachmentsTOTAL178Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 178Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 13,467Assist 178TOTAL FLARED VOLUME 13,823 Flare Start Date 08/01/2020 Flare End Date 08/31/2020 FS2 Flare Report Total Volume (MSCF) 178 Report Number System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 20-145 Controlled Blowdown 08/03/2020 5:00:00 pm 8:30:00 pm 210 min No No No HEC-HOU\CH4 749 178 Plant startup flaring off slugcatchers.Determination Cause Started 1804Action Taken Daily Volume (MSCF)178 Total Volume (MSCF) 178 Generated 09/04/2020 12:14:32PM Pa ge 4 of 8 2. Facility Name PBU FS 2 Percent 100.00% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition 0290000029 PBU - EOA HILCORP September-2020 Disposition Volume MCF 20.For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code 7. Reinjected 0 PRUDHOE 640150 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.)0 10. Pilot and Purge 12,919 11. Assist Gas 2,377 13. Other (see instructions)0 Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-12)630,141 Lease Use 12. Fuel gas used in lease operations.614,845 Date MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: 17. Transferred from: CGF 211,835 18. Transferred to: (Express as a negative #) CGF -24,152,708 Commissioner (346) 237-2244 Date 10/14/2020 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Tommy Hoang Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235.Printed Name Tommy Hoang Phone Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate HILCORP ALASKA PRUDHOE BAY UNIT - FS-2 GAS FLARING AND VENTING INCIDENT REPORT September 2020 Unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 12,919 Assist 2,377 TOTAL FLARED VOLUME 15,296 2. Facility Name PBU FS 2 Percent 100.00% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition 0290000029 PBU - EOA HILCORP October-2020 Disposition Volume MCF 20.For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code 7. Reinjected 0 PRUDHOE 640150 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.)0 10. Pilot and Purge 13,334 11. Assist Gas 213 13. Other (see instructions)0 Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-12)660,991 Lease Use 12. Fuel gas used in lease operations.647,444 Date MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: 17. Transferred from: CGF 216,140 18. Transferred to: (Express as a negative #) CGF -24,176,485 Commissioner (346) 237-2244 Date 11/13/2020 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235.Printed Name Tommy Hoang Phone Tommy Hoang Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate HILCORP ALASKA PRUDHOE BAY UNIT - FS-2 GAS FLARING AND VENTING INCIDENT REPORT October 2020 Unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 13,334 Assist 213 TOTAL FLARED VOLUME 13,547 2. Facility Name PBU FS 2 Percent 100.00% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition 0290000029 PBU - EOA Hilcorp North Slope, LLC November-2020 Disposition Volume MCF 20.For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code 7. Reinjected 0 PRUDHOE 640150 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.)0 10. Pilot and Purge 12,408 11. Assist Gas 15 13. Other (see instructions)0 Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-12)692,303 Lease Use 12. Fuel gas used in lease operations.679,880 Date MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: 17. Transferred from: CGF 223,329 18. Transferred to: (Express as a negative #) CGF -23,334,409 Commissioner (346) 237-2244 Date 12/16/2020 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Tommy Hoang Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235.Printed Name Tommy Hoang Phone Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate HILCORP ALASKA PRUDHOE BAY UNIT - FS-2 GAS FLARING AND VENTING INCIDENT REPORT November 2020 Unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 12,408 Assist 15 TOTAL FLARED VOLUME 12,423 2. Facility Name PBU FS 2 Percent 100.00% MCF 19. Remarks: -25,131,194 Commissioner 346-237-2244 Date 1/15/2021 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Tommy Hoang Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235.Printed Name Tommy Hoang Phone 12. Fuel gas used in lease operations.727,951 Date MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: 17. Transferred from: CGF 234,618 18. Transferred to: (Express as a negative #) CGF 13. Other (see instructions)0 Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-12)745,382 Lease Use 11. Assist Gas 83 9. Flared or vented more than 1 hour (see instr.)0 10. Pilot and Purge 12,748 8. Flared or vented 1 hour or less 4,600 0290000029 PBU - EOA HILCORP NORTH SLOPE December-2020 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code 7. Reinjected 0 PRUDHOE 640150 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate HILCORP ALASKA PRUDHOE BAY UNIT - FS-2 GAS FLARING AND VENTING INCIDENT REPORT December 2020 Unplanned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 12/27/2020 0404-0440 4,600 Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 4,600 Unplanned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE Not required for events <= 1 hr Not required for events <= 1 hr TOTAL 0 Planned events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 4,600 Unplanned Events > 1 Hour 0 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 12,748 Assist 83 TOTAL FLARED VOLUME 17,431