Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutColville River - ConocoPhillips Alaska, Inc2. Facility Name1030000017Colville River Unit Processing FacilityJanuary-22Percent94.8%3.3%2.0%0.0%016,504100.0%COMMISSIONERComm. Comm.19. Remarks:Gas sold to Alpine Transportation Company = 17,990Gas gifted to Village of Nuiqsut = 15,372Gas sold to GMTU= 0Title:Authorized Name and Digital Signature with Date:1/20/202217. Transferred from:706,17618. Transferred to: (Express as a negative #)918-661-9722I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? 14. TOTAL VOLUME (ITEMS 6-13)3,023,680MCF15. NGL Gas EquivalentWaste: MCF16. Purchased gas0Reviewed by:Conservation: MCFLease Use:11. Assist Gas012. Fuel gas used in lease operations.538,084AOGCC Use OnlySafety: MCFAuthorization >1 hr:13. Other (see instructions)10. Pilot and Purge9. Flared or vented more than 1 hour (see instr.)8. Flared or vented 1 hour or less866 QANNIK 120180OTHERColville River Unit ConocoPhillips Alaska, Inc.Disposition Volume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. Sold33,362Pool Name Pool Code7. Reinjected2,434,864 ALPINE 120100NANUQ-NANUQ 120175STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionDate of Revision:Revenue AnalystNote: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60oF. Authority 20 AAC25.235.Contact Phone:Contact Email: cristina.huddleston@cop.com Cristina HuddlestonForm 10-422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov CONOCOPHILLIPS ALASKA, INCCONSERVATION ORDER NO. 443ALPINEALPINE PROCESSING FACILITYGAS FLARING INCIDENTSJan-22START END PLANNED VOLUMEDATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUMETotal Flare > 1 Hour0Total Flare <= 1 Hour866Pilot and Purge16,504Total Flare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acility Name1030000017Colville River Unit Processing FacilityApril-22Percent92.2%4.1%3.4%0.3%8,33423,197100.0%COMMISSIONERComm. Comm.19. Remarks:Gas sold to Alpine Transportation Company = 17,648Gas gifted to Village of Nuiqsut = 12,722Gas sold to GMTU= 0Title:Authorized Name and Digital Signature with Date:5/20/2022Date of Revision:Revenue AnalystNote: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60oF. Authority 20 AAC25.235.Contact Phone:Contact Email: cristina.huddleston@cop.com Cristina HuddlestonSTATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionColville River Unit ConocoPhillips Alaska, Inc.Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent of TotalVolume.6. Sold30,370Pool Name Pool Code7. Reinjected3,546,750 ALPINE 120100NANUQ-NANUQ 1201758.Flared or vented 1 hour or less516 QANNIK 120180OTHER9.Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist Gas012.Fuel gas used in lease operations.482,239AOGCC Use OnlySafety: MCFAuthorization >1 hr:13.Other (see instructions)14. TOTAL VOLUME (ITEMS 6-13)4,091,406MCF15.NGL Gas EquivalentWaste: MCF16.Purchased gas0Reviewed by:Conservation: MCFLease Use:17.Transferred from:2,000,28718.Transferred to: (Express as a negative #)918-661-9722I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? Form 10-422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov %43JLC 8/17/2023GCW 08/17/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.08.23 10:01:13 -08'00' CONOCOPHILLIPS ALASKA, INCCONSERVATION ORDER NO. 443ALPINEALPINE PROCESSING FACILITYGAS FLARING INCIDENTSApr-22START END PLANNED VOLUMEDATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME04/12/2022 02:03 04/12/2022 03:47U118Facility Oil and Gas Trains had to be shutdown due to identification of a cracked weld on the 2nd stage compressor balance line. The facility was brought down to allow repairs to lineRepaired cracked weld on balance line04/12/2022 16:59 04/12/2022 23:57U8210 Flaring for facility restart. Compressor train down for pipe repair.Started/restarted t/c # 33012 & 32012. Upon restart of gas compression train a mechanical safety valve failed and had to be repaired causing longer than normal start up.04/12/2022 16:59 04/12/2022 18:00U6 Flaring for facility restart. Compressor train down for pipe repair.Started/restarted t/c # HP C-33012. Upon restart of gas compression train a mechanical safety valve failed and had to be repaired causing longer than normal start up.Total Flare > 1 Hour8,334Total Flare <= 1 Hour516Pilot and Purge23,197Total Flare32,047 2. Facility Name1030000017Colville River Unit Processing FacilityMay-22Percent94.2%4.3%1.4%0.0%7,12623,475100.0%COMMISSIONERComm. Comm.19. Remarks:Gas sold to Alpine Transportation Company = 26,599Gas gifted to Village of Nuiqsut = 10,621Gas sold to GMTU= 0Title:Authorized Name and Digital Signature with Date:6/20/2022Date of Revision:Revenue AnalystNote: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60oF. Authority 20 AAC25.235.Contact Phone:Contact Email: cristina.huddleston@cop.com Cristina HuddlestonSTATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionColville River Unit ConocoPhillips Alaska, Inc.Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent of TotalVolume.6. Sold37,220Pool Name Pool Code7. Reinjected4,357,064 ALPINE 120100NANUQ-NANUQ 1201758. Flared or vented 1 hour or less7,326 QANNIK 120180OTHER9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist Gas012. Fuel gas used in lease operations.494,698AOGCC Use OnlySafety: MCFAuthorization >1 hr:13. Other (see instructions)14. TOTAL VOLUME (ITEMS 6-13)4,926,909MCF15. NGL Gas EquivalentWaste: MCF16. Purchased gas0Reviewed by:Conservation: MCFLease Use:17. Transferred from:2,633,02518. Transferred to: (Express as a negative #)918-661-9722I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? Form 10-422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov7126WCB 8-31-2023($8JLC 11/29/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.11.29 14:47:16 -09'00' CONOCOPHILLIPS ALASKA, INCCONSERVATION ORDER NO. 443ALPINEALPINE PROCESSING FACILITYGAS FLARING INCIDENTSMay-22START END PLANNED VOLUMEDATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME05/07/2022 11:12 05/07/2022 19:11U5392Facility Oil Train shutdown due to Fire Detect in A2 Module, resulting in all intrumnentation and equipment to go to Fail Safe postion which caused shutdown of Oil train, Produced Water Injection, and part of Gas section. Sections of facility that were shut down were then able to be returned to service after determined facility was in a safe starting state.Verified cause was eliminated. Open Flame Work outside module was the cause of fire detection when roll up garage door was opened to retrieve materials05/09/2022 09:30 05/09/2022 16:54U1734The Low Pressure compressor was having maintenance performed when logic from Mark6E tripped the compressor. Work was completed and attempt to restart 13.8 V electric driven compressor was initiated. Initiation failed and the compressor motor would not start. Troubleshooting resulted in identifiying a failed breaker. Electricians swapped out breakers to restore electircal power to the motor and the initaion of the low pressure compressorRepaired equipment, facility maintenance completed. These are large 13.8 Volt breakers that had to be changed out causing duration of restart to be delayedTotal Flare > 1 Hour7,126Total Flare <= 1 Hour7,326Pilot and Purge23,475Total Flare37,927 2. Facility Name1030000017Colville River Unit Processing FacilityJune-22Percent94.7%4.3%1.0%0.0%3,38620,986100.0%COMMISSIONERComm. Comm.19. Remarks:Gas sold to Alpine Transportation Company = 30,796Gas gifted to Village of Nuiqsut = 7,957Gas sold to GMTU= 0Title:Authorized Name and Digital Signature with Date:7/20/202217. Transferred from:2,285,09818. Transferred to: (Express as a negative #)918-661-9722I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? 14. TOTAL VOLUME (ITEMS 6-13)4,489,609MCF15. NGL Gas EquivalentWaste: MCF16. Purchased gas0Reviewed by:Conservation: MCFLease Use:11. Assist Gas012. Fuel gas used in lease operations.443,166AOGCC Use OnlySafety: MCFAuthorization >1 hr:13. Other (see instructions)10. Pilot and Purge9. Flared or vented more than 1 hour (see instr.)8. Flared or vented 1 hour or less4,437 QANNIK 120180OTHERColville River Unit ConocoPhillips Alaska, Inc.Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent of TotalVolume.6. Sold38,753Pool Name Pool Code7. Reinjected3,978,881 ALPINE 120100NANUQ-NANUQ 120175STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionDate of Revision:Revenue AnalystNote: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60oF. Authority 20 AAC25.235.Contact Phone:Contact Email: cristina.huddleston@cop.com Cristina HuddlestonForm 10-422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov3386WCB 8-31-2023($8JLC 11/29/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.11.29 15:01:23 -09'00' CONOCOPHILLIPS ALASKA, INCCONSERVATION ORDER NO. 443ALPINEALPINE PROCESSING FACILITYGAS FLARING INCIDENTSJun-22START END PLANNED VOLUMEDATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME06/16/2022 13:11 06/16/2022 14:26U205 Flare due to plant upset caused by warm ambient temperatureReduced/increased inlet gas rates, stablilized facility process and operation06/16/2022 14:30 06/16/2022 17:39U1444Due to low level in the gas condensate flash vessel, the stabilizer unit shutdown and the LP compressor started flaringReduced/increased inlet gas rates, stablilized facility process and operation06/25/2022 18:12 06/25/2022 19:38U985Flared due to plant upset cause by warm ambient temperature, upsetting C1 Gas compressor.Reduced/increased inlet gas rates, stablilized facility process and operation06/26/2022 16:18 06/26/2022 17:20U680Flared due to plant upset cause by warm ambient temperature, upsetting C1 Gas compressor.Reduced/increased inlet gas rates, stablilized facility process and operation06/28/2022 05:01 06/28/2022 11:27U53Flared for 2 hours 9 minutes from unknown Gas source leaking into the LP Flare header. Problem leak appeared to havecorrected itself and was unable to be identified. Flared again for 1 hour 28 minutes from unknown Gas source leaking into LP Flare header, again,problem leak appeared to correct itself and was unable to be identified.Operations could not source where the gas leak came from and problem appeared to correct itself.06/29/2022 23:46 06/30/2022 01:01U20Flared for 1 hours 15 minutes from unknown Gas source leaking into the LP Flare header.Operations identified the source from a from a malfunctioning valve to flare, PV-33033 and were able to isolate the leak. Work order was raised andequipment in the planning schedule for repairTotal Flare > 1 Hour3,386Total Flare <= 1 Hour4,437Pilot and Purge20,986Total Flare28,809 )DFLOLW\1DPH&ROYLOOH5LYHU8QLW3URFHVVLQJ)DFLOLW\-XO\3HUFHQW&200,66,21(5&RPP &RPP5HPDUNV*DVVROGWR$OSLQH7UDQVSRUWDWLRQ&RPSDQ\  *DVJLIWHGWR9LOODJHRI1XLTVXW  *DVVROGWR*078 7LWOH$XWKRUL]HG1DPHDQG'LJLWDO6LJQDWXUHZLWK'DWH'DWHRI5HYLVLRQ5HYHQXH$QDO\VW1RWH All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60oF. Authority 20 AAC25.235.&RQWDFW3KRQH&RQWDFW(PDLOFULVWLQDKXGGOHVWRQ#FRSFRP&ULVWLQD+XGGOHVWRQ67$7(2)$/$6.$$/$6.$2,/$1'*$6&216(59$7,21&200,66,21)$&,/,7<5(32572)352'8&('*$6',6326,7,21)DFLOLW\1XPEHU )LHOG 2SHUDWRU 0RQWK<HDURI'LVSRVLWLRQ&ROYLOOH5LYHU8QLW &RQRFR3KLOOLSV$ODVND,QF'LVSRVLWLRQ 9ROXPH0&)For production from multiple pools, list contribution of each pool as a percent of Total Volume.6ROG3RRO1DPH 3RRO&RGH5HLQMHFWHG $/3,1( 1$1841$184 )ODUHGRUYHQWHGKRXURUOHVV 4$11,. 27+(5)ODUHGRUYHQWHGPRUHWKDQKRXU VHHLQVWU 3LORWDQG3XUJH$VVLVW*DV)XHOJDVXVHGLQOHDVHRSHUDWLRQV$2*&&8VH2QO\6DIHW\ 0&)$XWKRUL]DWLRQ!KU2WKHU VHHLQVWUXFWLRQV 727$/92/80( ,7(06 0&)1*/*DV(TXLYDOHQW:DVWH 0&)3XUFKDVHGJDV5HYLHZHGE\&RQVHUYDWLRQ0&)/HDVH8VH7UDQVIHUUHGIURP7UDQVIHUUHGWR ([SUHVVDVDQHJDWLYH ,KHUHE\FHUWLI\WKDWWKHIRUHJRLQJLVWUXHDQGFRUUHFWWRWKHEHVWRIP\NQRZOHGJH5HYLVLRQ"&ŽƌŵϭϬͲϰϮϮZĞǀŝƐĞĚϭϬͬϮϬϮϭϮϬϮϱ͘Ϯϯϱ^ƵďŵŝƚŝŶW&ĨŽƌŵĂƚƚŽĂŽŐĐĐ͘ƌĞƉŽƌƚŝŶŐΛĂůĂƐŬĂ͘ŐŽǀ452WCB 8-31-2023($8JLC 11/29/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.11.29 15:10:01 -09'00' &212&23+,//,36$/$6.$,1&&216(59$7,2125'(512$/3,1($/3,1(352&(66,1*)$&,/,7<*$6)/$5,1*,1&,'(176-XO67$57 (1' 3/$11(' 92/80('$7( 7,0( '$7( 7,0( 813/$11(' 06&) '(6&5,37,212))/$5,1*(9(17 $&7,217$.(1720,1,0,=(92/80(   h)ODUHGXHWRSLJJLQJ&'SURGXFWLRQOLQHZKLFKFDXVHGIDFLOLW\LQVWDELOLW\6WDELOL]HGIDFLOLW\SURFHVVDQGRSHUDWLRQ UHGXFHGLQFUHDVHGLQOHWJDVUDWHVTotal Flare > 1 HourTotal Flare <= 1 HourPilot and Purge7RWDO)ODUH ConocoPhillips Alaska, Inc. P.O. Box 100360 Anchorage, Alaska 99510-0360 September 20, 2022 TO: Recipients of the Colville River Unit Participating Area Monthly Production Report of Gas Disposition Enclosed is the Produced Gas Disposition Report for August 2022 Please address any questions to Cristina Huddleston at (918) 661-9722. Sincerely, Cristina Huddleston Revenue Analyst Enclosures 2. Facility Name1030000017Colville River Unit Processing FacilityAugust-22Percent95.3%1.9%1.6%1.1%13,03526,421100.0%COMMISSIONERComm. Comm.19. Remarks:Gas sold to Alpine Transportation Company = 16,929Gas gifted to Village of Nuiqsut = 5,959Gas sold to GMTU= 0Title:Authorized Name and Digital Signature with Date:9/20/202217.Transferred from:2,036,83018.Transferred to: (Express as a negative #)918-661-9722I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? 14. TOTAL VOLUME (ITEMS 6-13)4,070,023MCF15.NGL Gas EquivalentWaste: MCF16.Purchased gas0Reviewed by:Conservation: MCFLease Use:11. Assist Gas012.Fuel gas used in lease operations.401,688AOGCC Use OnlySafety: MCFAuthorization >1 hr:13.Other (see instructions)10. Pilot and Purge9.Flared or vented more than 1 hour (see instr.)8.Flared or vented 1 hour or less2,917 QANNIK 120180OTHERColville River Unit ConocoPhillips Alaska, Inc.Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent of TotalVolume.6. Sold22,888Pool Name Pool Code7. Reinjected3,603,074 ALPINE 120100NANUQ-NANUQ 120175STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionDate of Revision:Revenue AnalystNote: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60oF. Authority 20 AAC25.235.Contact Phone:Contact Email: cristina.huddleston@cop.com Cristina HuddlestonForm 10-422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov74519074677WCB 10-2-2023($8JLC 11/29/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.11.29 15:19:26 -09'00' CONOCOPHILLIPS ALASKA, INCCONSERVATION ORDER NO. 443ALPINEALPINE PROCESSING FACILITYGAS FLARING INCIDENTSAug-22START END PLANNED VOLUMEDATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME08/14/2022 22:07 08/14/2022 23:51U1005A CPF2 automation download resulted in an inadvertent closure of the crude oil pipeline XV and shutdown of the crude oil shipping pumps. This then cascaded to an oil train shutdown.Reduced/increased inlet gas rates. Stabilized facility process and operation.08/22/2022 10:22 08/22/2022 18:31U6446Lost E9 power generator from faulty logic in control system. Caused a loadshed event which shut the plant down.Started S1 & S2 power generators to restore power in facility.08/25/2022 23:41 08/26/2022 07:58P888 Shut facility down for annual TAR compressor/train depressured08/26/2022 09:13 08/26/2022 10:28P19 Flared from annual failicty TAR maintenance activities compressor/train depressured08/29/2022 20:50 08/30/2022 05:43P4677 Flared for facility start-up post annual TAR Started C1 & C3 compressorsTotal Flare > 1 Hour13,035Total Flare <= 1 Hour2,917Pilot and Purge26,421Total Flare42,373 2. Facility Name 1030000017 Colville River Unit Processing Facility September-22 Percent 95.0% 3.2% 1.8% 0.0% 0 21,428 100.0% COMMISSIONER Comm. Comm. 19. Remarks:Gas sold to Alpine Transportation Company = 21,608 Gas gifted to Village of Nuiqsut = 9,015 Gas sold to GMTU= 0 Title: Authorized Name and Digital Signature with Date: 9/30/2022 17. Transferred from:2,219,853 18. Transferred to: (Express as a negative #) 918-661-9722 I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? 14. TOTAL VOLUME (ITEMS 6-13)4,832,976 MCF 15. NGL Gas Equivalent Waste: MCF 16. Purchased gas 0 Reviewed by: Conservation: MCFLease Use: 11. Assist Gas 0 12. Fuel gas used in lease operations.458,856 AOGCC Use Only Safety: MCF Authorization >1 hr: 13. Other (see instructions) 10. Pilot and Purge 9. Flared or vented more than 1 hour (see instr.) 8. Flared or vented 1 hour or less 3,818 QANNIK 120180 OTHER Colville River Unit ConocoPhillips Alaska, Inc. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 30,623 Pool Name Pool Code 7. Reinjected 4,318,251 ALPINE 120100 NANUQ-NANUQ 120175 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Date of Revision:Revenue Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235. Contact Phone: Contact Email: cristina.huddleston@cop.com Cristina Huddleston Form 10-422 Revised 10/2021 20 AAC 25.235 Submit in PDF format to aogcc.reporting@alaska.gov CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Sep-22 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME Total Flare > 1 Hour 0 Total Flare <= 1 Hour 3,818 Pilot and Purge 21,428 Total Flare 25,246 2. Facility Name 1030000017 Colville River Unit Processing Facility October-22 Percent 92.1% 3.3% 4.7% 0.0% 0 19,631 100.0% COMMISSIONER Comm. Comm. 19. Remarks:Gas sold to Alpine Transportation Company = 30,360 Gas gifted to Village of Nuiqsut = 10,696 Gas sold to GMTU= 0 Title: Authorized Name and Digital Signature with Date: 11/20/2022 Date of Revision:Revenue Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235. Contact Phone: Contact Email: patricia.grimm@contractor.conocop hillips.com Patty Grimm STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit ConocoPhillips Alaska, Inc. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 41,056 Pool Name Pool Code 7. Reinjected 3,977,034 ALPINE 120100 NANUQ-NANUQ 120175 8. Flared or vented 1 hour or less 911 QANNIK 120180 OTHER 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 11. Assist Gas 0 12. Fuel gas used in lease operations.484,708 AOGCC Use Only Safety: MCF Authorization >1 hr: 13. Other (see instructions) 14. TOTAL VOLUME (ITEMS 6-13)4,523,340 MCF 15. NGL Gas Equivalent Waste: MCF 16. Purchased gas 0 Reviewed by: Conservation: MCFLease Use: 17. Transferred from:1,857,324 18. Transferred to: (Express as a negative #) 918-661-9722 I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? Form 10-422 Revised 10/2021 20 AAC 25.235 Submit in PDF format to aogcc.reporting@alaska.gov CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Oct-22 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME Total Flare > 1 Hour 0 Total Flare <= 1 Hour 911 Pilot and Purge 19,631 Total Flare 20,542 2. Facility Name 1030000017 Colville River Unit Processing Facility November-22 Percent 93.3% 3.0% 3.7% 0.0% 0 20,944 100.0% COMMISSIONER Comm. Comm. 19. Remarks:Gas sold to Alpine Transportation Company = 18,241 Gas gifted to Village of Nuiqsut = 12,412 Gas sold to GMTU= 0 Title: Authorized Name and Digital Signature with Date: 12/20/2022 17. Transferred from:1,654,327 18. Transferred to: (Express as a negative #) 918-661-8638 I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? 14. TOTAL VOLUME (ITEMS 6-13)4,462,933 MCF 15. NGL Gas Equivalent Waste: MCF 16. Purchased gas 0 Reviewed by: Conservation: MCFLease Use: 11. Assist Gas 0 12. Fuel gas used in lease operations.498,272 AOGCC Use Only Safety: MCF Authorization >1 hr: 13. Other (see instructions) 10. Pilot and Purge 9. Flared or vented more than 1 hour (see instr.) 8. Flared or vented 1 hour or less 594 QANNIK 120180 OTHER Colville River Unit ConocoPhillips Alaska, Inc. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 30,653 Pool Name Pool Code 7. Reinjected 3,912,470 ALPINE 120100 NANUQ-NANUQ 120175 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Date of Revision:Revenue Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235. Contact Phone: Contact Email: patricia.grimm@contractor.conocop hillips.com Patty Grimm Form 10-422 Revised 10/2021 20 AAC 25.235 Submit in PDF format to aogcc.reporting@alaska.gov CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Nov-22 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME Total Flare > 1 Hour 0 Total Flare <= 1 Hour 594 Pilot and Purge 20,944 Total Flare 21,538 2. Facility Name1030000017Colville River Unit Processing FacilityDecember-22Percent94.8%2.3%2.9%0.0%50221,960100.0%COMMISSIONERComm. Comm.19. Remarks:Gas sold to Alpine Transportation Company = 18,861Gas gifted to Village of Nuiqsut = 14,738Gas sold to GMTU= 0Title:Authorized Name and Digital Signature with Date:January 20, 202317. Transferred from:1,273,52918. Transferred to: (Express as a negative #)918-661-8638I hereby certify that the foregoing is true and correct to the best of my knowledge.Revision? 14. TOTAL VOLUME (ITEMS 6-13)4,443,382MCF15.NGL Gas EquivalentWaste: MCF16.Purchased gas0Reviewed by:Conservation: MCFLease Use:11. Assist Gas012. Fuel gas used in lease operations.547,157AOGCC Use OnlySafety: MCFAuthorization >1 hr:13. Other (see instructions)10. Pilot and Purge9. Flared or vented more than 1 hour (see instr.)8. Flared or vented 1 hour or less1,784 QANNIK 120180OTHERColville River Unit ConocoPhillips Alaska, Inc.Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent of TotalVolume.6. Sold33,599Pool Name Pool Code7. Reinjected3,838,380 ALPINE 120100NANUQ-NANUQ 120175STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionDate of Revision:Revenue AnalystNote: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60oF. Authority 20 AAC25.235.Contact Phone:Contact Email: patricia.grimm@contractor.conocophillips.comPatty GrimmForm 10-422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov396106WCB 9-8-2023($8JLC 11/29/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.11.29 15:43:48 -09'00' CONOCOPHILLIPS ALASKA, INCCONSERVATION ORDER NO. 443ALPINEALPINE PROCESSING FACILITYGAS FLARING INCIDENTSDec-22START END PLANNED VOLUMEDATE TIME DATE TIME UNPLANNED (MSCF) DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME12/12/2022 11:33 12/12/2022 12:59U396 E9 tripped causing the LP compressor to load shed. Restarted E9 which allowed us to restart LP compressor12/29/2022 04:03 12/29/2022 01:03U106Operations was in the process of trying to bring on a well that was offlineWell was shut-in when it was apparent the compressor may not handle the rateTotal Flare > 1 Hour502Total Flare <= 1 Hour1,784Pilot and Purge21,960Total Flare24,246