Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU FS2 - Hilcorp North Slope, LLC2. Facility NamePBU FS 2Percent100.00%SafetyMCFLease MCFMCFWaste MCFReviewed by:Comm. Comm.19. Remarks:Authorized Name and Digital Signature with date:BethFarouse2/14/202316. Purchased gas017. Transferred from: CGF265,48518. Transferred to: (Express as a negative #) CGF-22,598,915Conservation12. Fuel gas used in lease operations.735,34415. NGL Gas Equivalent013. Other (see instructions)0Official Use Only14. TOTAL VOLUME (ITEMS 6-12)768,336Authorization >1 hr:11. Assist Gas3669. Flared or vented more than 1 hour (see instr.)19,38610. Pilot and Purge13,2408. Flared or vented 1 hour or less00290000029 PBU - EOA HILCORP NORTH SLOPE January-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionCOMMISSIONERI hereby certify that the foregoing is true and correct to the best of my knowledge.Revision?Date ofRevision:Contact Phone: (713)289-2627Note: All volumes must becorrected to pressure of 14.65 psiaand to a temperature of 60° F.Authority 20 AAC 25.235.Contact Email:bfarouse@hilcorp.comTitle: Production AnalystForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.02.15 14:59:25 -06'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 11:48:25 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTJanuary 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE1/26/2023 1315:1700 18,900 See Attachments See Attachments1/26/2023 1700:2035 486TOTAL19,386Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 19,386Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 13,240Assist 366TOTAL FLARED VOLUME 32,992         ()'*           !"## $   !   % $ >  & 8      2 9: .*69 #4  0 '$4 &'    4 $  &$ 4 $'$  #$&$4 3+4 $     6#4  9 &   !  % $  "%"  #  % $ >  & 8  9     2  98 9 6 $ 44 " $ '$   4 5 6 $ 7    9 6 $ $  $ %"  # 2$ 3, 4 5-6%7 :98 ()'* < $ ! 8  +-*$" & 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition0290000029 PBU - EOA HILCORP NORTH SLOPE February-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 6401508. Flared or vented 1 hour or less5,1009. Flared or vented more than 1 hour (see instr.)36010. Pilot and Purge11,88711. Assist Gas1,620MCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)680,994Conservation:12. Fuel gas used in lease operations.662,027AOGCC Use OnlyAuthorization >1 hr:Safety:MCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1238,277COMMISSIONER18. Transferred to: (Express as a negative #)-21,056,277Comm. Comm.bfarouse@hilcorp.comForm 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 3/16/2023Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.03.17 11:37:41 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 11:49:49 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTFebruary 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE2/22/2023 1700:1736 5,100 Not required for events <= 1 hr Not required for events <= 1 hrTOTAL 5,100Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE2/22/2023 1700:1830 360 See Attachments See AttachmentsTOTAL360Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 5,100Unplanned Events > 1 Hour 360Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 11,887Assist 1,620TOTAL FLARED VOLUME 18,967          )+'            !"## $    !  $ 5 <7  ( :( $          !99 :   ,%-#+%! &'   ' ( ) *  & %"  # <   ? ,%-#+% 1 23- '4", 56: )+' 8   $ $9"+. 7 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 4/20/202318. Transferred to: (Express as a negative #)-23,763,092Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1264,538COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)746,420Conservation:12. Fuel gas used in lease operations.733,200AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas1710. Pilot and Purge13,2039. Flared or vented more than 1 hour (see instr.)08. Flared or vented 1 hour or less00290000029 PBU - EOA HILCORP NORTH SLOPE March-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.04.18 16:10:46 -05'00'Beth Farouse(909) HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTMarch 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 13,203Assist 17TOTAL FLARED VOLUME 13,220 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 5/16/202318. Transferred to: (Express as a negative #)-22,706,491Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1255,496COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)710,192Conservation:12. Fuel gas used in lease operations.692,432AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas3,01810. Pilot and Purge12,8249. Flared or vented more than 1 hour (see instr.)1,7908. Flared or vented 1 hour or less1280290000029 PBU - EOA HILCORP NORTH SLOPE April-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.05.16 10:17:51 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 12:06:45 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTApril 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE4/16/2023 0240:0245 64 Not required for events <= 1 hr Not required for events <= 1 hr4/18/2023 0330:0336 64TOTAL 128Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE4/16/2023 0257:0515 833 See Attachments See Attachments4/16/2023 1516:1623 204/18/2023 0400:0608 6254/19/2023 0841:0956 312TOTAL1,790Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 128Unplanned Events > 1 Hour 1,790Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 12,824Assist 3,018TOTAL FLARED VOLUME 17,760         +),           !    "#$$ %    "  $        #          ! $ #    "! GGGG% .  /#% .  /'   (- &#   $  % % .  /- $      % %           ! $     "! GGGG% .  /3  ( &#   $  % % .  /-3  (. %  167 &890 :;# #     #  # #          ! $     "! GGGG% .  /#% . '   ( &#   $  % % .  /- 167 &890 :; #     $ # $           ! $     "! GGGG% .  / #  ( &#   $  % % .  /- 167 &890 :; +), >    $@9 @/$ ' 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 6/15/202318. Transferred to: (Express as a negative #)-23,500,362Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1265,173COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)754,188Conservation:12. Fuel gas used in lease operations.717,708AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas23,27710. Pilot and Purge13,1899. Flared or vented more than 1 hour (see instr.)08. Flared or vented 1 hour or less140290000029 PBU - EOA HILCORP NORTH SLOPE May-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by BethFarouse (909)DN: cn=Beth Farouse (909)Date: 2023.06.15 16:01:09 -05'00'Beth Farouse(909) HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTMay 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE5/14/2023 0805:0815 14 Not required for events <= 1 hr Not required for events <= 1 hrTOTAL 14Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 14Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 13,189Assist 23,277TOTAL FLARED VOLUME 36,480 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 7/18/202318. Transferred to: (Express as a negative #)-21,329,675Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1243,565COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)677,058Conservation:12. Fuel gas used in lease operations.656,157AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas8,03310. Pilot and Purge12,4319. Flared or vented more than 1 hour (see instr.)4378. Flared or vented 1 hour or less00290000029 PBU - EOA HILCORP NORTH SLOPE June-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by BethFarouse (909)DN: cn=Beth Farouse (909)Date: 2023.07.19 13:16:59 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 12:20:58 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTJune 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE6/3/2023 0900:1030 437 See Attachments See AttachmentsTOTAL437Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 437Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 12,431Assist 8,033TOTAL FLARED VOLUME 20,901         +(           !"## $   !   4  : '  ,  ,     B,6 6 $> > >480) ''  &  - '   - '' %C  +    2 & /; )@480> > >+%"  # . /0 &12345 6 +( 7   6 82 9- '6 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 8/17/202318. Transferred to: (Express as a negative #)-17,960,279Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1178,761COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)529,013Conservation:12. Fuel gas used in lease operations.507,687AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas3,37410. Pilot and Purge13,0859. Flared or vented more than 1 hour (see instr.)4,6258. Flared or vented 1 hour or less2420290000029 PBU - EOA HILCORP NORTH SLOPE July-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by BethFarouse (909)DN: cn=Beth Farouse (909)Date: 2023.08.17 16:48:48 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 12:26:30 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTJuly 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE7/11/2023 1221:1227 64 Not required for events <= 1 hr Not required for events <= 1 hr12/28/1905 0941:0946 50TOTAL 114Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE7/7/2023 0930:1100 3,996 See Attachments See Attachments7/22/2023 1330:1900 379TOTAL4,375Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE7/7/2023 0109:0113 64 Not required for events <= 1 hr Not required for events <= 1 hr7/7/2023 0835:0840 64TOTAL128Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE7/7/2023 0140:0340 250 See Attachments See AttachmentsTOTAL250 TOTALUnplanned Events < 1 Hour 114Unplanned Events > 1 Hour 4,375Planned Events < 1 hour and not 128exceeding 5,000 MCFPlanned Events > 1 hour or 250exceeding 5,000 MCFPilot Purge 13,085Assist 3,374TOTAL FLARED VOLUME 21,326         *(5  7 ( > '  "( "(       2"    $ #%&   '  ( (  ( +-7 (  ''/2 %"  # 7(+  3%&   +           9( ( 9         2" 99   7& 7(+  3;2   ;(        ' 7(+  3/%&   - %"  #        "9                  @2"#" 9   2 & ( F. &+  ( #"F./+     ( ('( + (+<'  , / &,( +% %"  #   ( F. &+  ( F./+    2( 34 &56/789 *(5 =  ( #" 9.6 .(, ' 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition0290000029 PBU - EOA HILCORP NORTH SLOPE August-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 6401508. Flared or vented 1 hour or less09. Flared or vented more than 1 hour (see instr.)010. Pilot and Purge12,53811. Assist Gas24MCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)676,608Conservation:12. Fuel gas used in lease operations.664,046AOGCC Use OnlyAuthorization >1 hr:Safety:MCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1249,338COMMISSIONER18. Transferred to: (Express as a negative #)-20,460,972Comm. Comm.bfarouse@hilcorp.comForm 10-422 Revised 10/2021Block 6: Gas equivalent of NGLs &Propane;Block 12 includes 303 MCF of Propane, Block 15 includes 303 MCF of Propane Block 18: Includes MI Gas to Pt.McIntyre = 1,279,638 mscfI hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 9/20/2023Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.09.20 10:12:22 -05'00'Beth Farouse (909) HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTAugust 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 12,538Assist 24TOTAL FLARED VOLUME 12,562 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 10/19/202318. Transferred to: (Express as a negative #)-18,721,905Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1222,105COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)584,109Conservation:12. Fuel gas used in lease operations.566,275AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas2,50310. Pilot and Purge12,2859. Flared or vented more than 1 hour (see instr.)2,7608. Flared or vented 1 hour or less2860290000029 PBU - EOA HILCORP NORTH SLOPE September-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.10.19 10:10:05 -05'00'Beth Farouse (909):&%*&:JLC 12/13/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.27 09:24:55 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTSeptember 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE9/29/2023 0448:0457 66 Not required for events <= 1 hr Not required for events <= 1 hr9/29/2023 1343:1409 1569/29/2023 2116:2124 64TOTAL 286Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE9/29/2023 0858:1044 640 See Attachments See Attachments9/29/2023 1745:2114 1,254TOTAL1,894Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE9/21/2023 0130:0449 866 See Attachments See AttachmentsTOTAL866 TOTALUnplanned Events < 1 Hour 286Unplanned Events > 1 Hour 1,894Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 866exceeding 5,000 MCFPilot Purge 12,285Assist 2,503TOTAL FLARED VOLUME 17,834         )(+*           !    "#$$ %    "                  ! 1 $    #! $/+   & '    , &#   $  ' ' +  (-       $$            !9?$     #! $' ,  (&   / &#   $  '   / (-       ' '           !9?$     #! $' ,  ( &#   $  ' ' ,  (- "56 +783 9:1 )(+* >    $$=8 2( & 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 11/16/202318. Transferred to: (Express as a negative #)-20,334,020Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1246,328COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)665,054Conservation:12. Fuel gas used in lease operations.650,480AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas99910. Pilot and Purge12,8059. Flared or vented more than 1 hour (see instr.)6408. Flared or vented 1 hour or less1300290000029 PBU - EOA HILCORP NORTH SLOPE October-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.11.17 14:56:34 -06'00'Beth Farouse (909):&%:08/16/2024JLC 8/15/2024 HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTOctober 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE10/5/2023 1500:1510 65 Not required for events <= 1 hr Not required for events <= 1 hr10/5/2023 2000:2010 65TOTAL 130Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE10/5/2023 0015:0200 640 See Attachments See AttachmentsTOTAL640Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 130Unplanned Events > 1 Hour 640Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 12,805Assist 999TOTAL FLARED VOLUME 14,574         +'            !"## $    !    %           49 7   $ #) - '  % %"  # )  % . 0 12 & 34+567 +' >   ##94 *. #' 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 12/15/202318. Transferred to: (Express as a negative #)-19,744,848Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1256,595COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)701,490Conservation:12. Fuel gas used in lease operations.679,315AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas5,22010. Pilot and Purge13,2939. Flared or vented more than 1 hour (see instr.)3,6628. Flared or vented 1 hour or less00290000029 PBU - EOA HILCORP NORTH SLOPE November-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.12.19 15:59:34 -06'00'Beth Farouse (909):&%*&:Jessie L. ChmielowskiDigitally signed by Jessie L. Chmielowski Date: 2024.09.30 20:16:02 -08'00' HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTNovember 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE11/9/2023 1900:0000 1,274 See Attachments See Attachments11/10/2023 0001:1420 2,388TOTAL3,662Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 3,662Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 13,293Assist 5,220TOTAL FLARED VOLUME 22,175         ))           !"## $   !  7 3 <9 ! 7&       E!7 7 3%& &   % ( #%  ( #$%    9- -,    2$%  & %)  % 9## *'C / *  (& *)?  ,%"  # ./0 %12 34 7 7 3 <9  & & !     E5-- ($ )%#&   % (=&    ,    6   #  A%& * %($ *)?  ,%"  # ./0 %12 34 -- )) ;    !56( 9! 2. Facility NamePBU FS 2Percent100.0%19. Remarks:Title:Form 10-422 Revised 10/2021=I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 1/16/202418. Transferred to: (Express as a negative #)-21,528,089Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS1285,731COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)757,994Conservation:12. Fuel gas used in lease operations.745,201AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge12,7939. Flared or vented more than 1 hour (see instr.)08. Flared or vented 1 hour or less00290000029 PBU - EOA HILCORP NORTH SLOPE December-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2024.01.18 09:51:53 -06'00'Beth Farouse (909) HILCORP ALASKAPRUDHOE BAY UNIT - FS-2GAS FLARING AND VENTING INCIDENT REPORTDecember 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 12,793Assist 0TOTAL FLARED VOLUME 12,793