Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU GC2 - Hilcorp North Slope, LLC2. Facility NamePBU GC 2Percent85.67%3.03%5.40%3.31%2.59%SafetyMCFLease MCFMCFWaste MCFReviewed by:Comm. Comm.19. Remarks:Authorized Name and Digital Signature with date:BethFarouse2/14/202316. Purchased gas017. Transferred from:018. Transferred to: (Express as a negative #) CGF-22,750,399Conservation12. Fuel gas used in lease operations.770,30815. NGL Gas Equivalent013. Other (see instructions)0Official Use Only14. TOTAL VOLUME (ITEMS 6-12)802,195Authorization >1 hr:11. Assist Gas09. Flared or vented more than 1 hour (see instr.)0POLARIS 64016010. Pilot and Purge31,887AURORA 6401208. Flared or vented 1 hour or less0BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE January-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionCOMMISSIONERI hereby certify that the foregoing is true and correct to the best of my knowledge.Revision?Date ofRevision:Contact Phone: (713)289-2627Note: All volumes must becorrected to pressure of 14.65 psiaand to a temperature of 60° F.Authority 20 AAC 25.235.Contact Email:bfarouse@hilcorp.comTitle: Production AnalystForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.02.15 15:00:10 -06'00'Beth Farouse(909) HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTJanuary 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 31,887Assist 0TOTAL FLARED VOLUME 31,887 2. Facility NamePBU GC 2Percent85.5%3.0%5.7%3.4%2.4%19. Remarks:Title:STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition0290000032 PBU - WOA HILCORP NORTH SLOPE February-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150AURORA 6401208. Flared or vented 1 hour or less0BOREALIS 640130ORION 6401359. Flared or vented more than 1 hour (see instr.)9,161POLARIS 64016010. Pilot and Purge28,83311. Assist Gas0MCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)757,521Conservation:12. Fuel gas used in lease operations.719,527AOGCC Use OnlyAuthorization >1 hr:Safety:MCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONER18. Transferred to: (Express as a negative #)-20,762,314Comm. Comm.bfarouse@hilcorp.comForm 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 3/16/2023Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.03.17 11:38:20 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 11:50:17 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTFebruary 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE2/24/2023 1012:1228 9,161See Attachments See AttachmentsTOTAL9,161Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 9,161Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 28,833Assist 0TOTAL FLARED VOLUME 37,994         &+&           !"## $   !   5 <7   ( :      !8$$: .&.    ( ' *')3 +* (  ( )'   ,21    B9 '*( '*     &'  =' .*71B &'   *& /)*/   .  & ' 1 %"  # 23- '4", 56 $: &+& 8   $ $9"+.: 7 2. Facility NamePBU GC 2Percent14.7%28.6%25.5%18.7%12.5%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 4/20/202318. Transferred to: (Express as a negative #)-22,509,972Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)829,734Conservation:12. Fuel gas used in lease operations.798,101AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge31,6339. Flared or vented more than 1 hour (see instr.)0POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less0BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE March-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.04.18 16:11:12 -05'00'Beth Farouse(909) HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTMarch 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 31,633Assist 0TOTAL FLARED VOLUME 31,633 2. Facility NamePBU GC 2Percent84.7%3.1%5.6%3.8%2.8%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 5/16/202318. Transferred to: (Express as a negative #)-20,096,453Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)730,463Conservation:12. Fuel gas used in lease operations.697,154AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge30,8009. Flared or vented more than 1 hour (see instr.)2,192POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less317BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE April-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse(909)DN: cn=Beth Farouse (909),ou=UsersDate: 2023.05.16 10:18:21 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 12:07:20 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTApril 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE4/9/2023 1128:1208 317 Not required for events <= 1 hr Not required for events <= 1 hrTOTAL317Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE4/8/2023 1641:1933 1,194See Attachments See Attachments4/9/2023 1839:2052 998TOTAL2,192 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 317exceeding 5,000 MCFPlanned Events > 1 hour or 2,192exceeding 5,000 MCFPilot Purge 30,800Assist 0TOTAL FLARED VOLUME 33,309         +,           !    "#$$ %    "  # : 5' # % %          !H $    3  (I &#   $ 3  (. % - 167 &890 :;$  : 5' $ $% #%          !H $$#    3  (I &#   $ 3  (. % - 167 &890 :;$$# +, >    $@9 @/ ' 2. Facility NamePBU GC 2Percent83.4%3.1%7.2%4.3%2.0%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 6/15/202318. Transferred to: (Express as a negative #)-21,407,435Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)804,956Conservation:12. Fuel gas used in lease operations.754,346AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge31,3139. Flared or vented more than 1 hour (see instr.)0POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less19,297BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE May-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by BethFarouse (909)DN: cn=Beth Farouse (909)Date: 2023.06.15 16:01:43 -05'00'Beth Farouse(909) HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTMay 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE5/5/2023 2045:2131 19,297 Not required for events <= 1 hr Not required for events <= 1 hrTOTAL19,297Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 19,297exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 31,313Assist 0TOTAL FLARED VOLUME 50,610 2. Facility NamePBU GC 2Percent84.2%2.9%5.7%5.1%2.1%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 7/18/202318. Transferred to: (Express as a negative #)-20,127,403Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)748,589Conservation:12. Fuel gas used in lease operations.686,113AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge30,3329. Flared or vented more than 1 hour (see instr.)32,144POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less0BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE June-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by BethFarouse (909)DN: cn=Beth Farouse (909)Date: 2023.07.19 13:17:26 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 12:22:47 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTJune 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE6/16/2023 0445:1003 32,144 See Attachments See AttachmentsTOTAL32,144Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 32,144Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 30,332Assist 0TOTAL FLARED VOLUME 62,476         (,++           !"## $   !   4  : '    $     7,6  E  '   ->  ))& % ( &  '('    )+      (  @  % ; '% &   +%"  # . /0 &12345  (,++ 7   6 82 9- '6 2. Facility NamePBU GC 2Percent84.6%2.5%5.4%5.5%2.1%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 8/17/202318. Transferred to: (Express as a negative #)-21,463,640Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)724,722Conservation:12. Fuel gas used in lease operations.693,556AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge31,0749. Flared or vented more than 1 hour (see instr.)92POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less0BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE July-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by BethFarouse (909)DN: cn=Beth Farouse (909)Date: 2023.08.17 16:49:17 -05'00'Beth Farouse(909):&%*&:JLC 12/7/2023Brett W. Huber, Sr.Digitally signed by Brett W. Huber, Sr. Date: 2023.12.11 12:26:51 -09'00' HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTJuly 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE7/29/2023 0200:0400 92 See Attachments See AttachmentsTOTAL92 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 92exceeding 5,000 MCFPilot Purge 31,074Assist 0TOTAL FLARED VOLUME 31,166                    !"## $   !       9 ( "(     >"9 . (  &  '.'     (  ( + <-    6(  ( + <+   ( '   :(+<  *+-%"  # 2( 34 &56/78 9  2. Facility NamePBU GC 2Percent85.5%1.6%5.1%5.7%2.1%19. Remarks:Title:STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition0290000032 PBU - WOA HILCORP NORTH SLOPE August-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150AURORA 6401208. Flared or vented 1 hour or less120BOREALIS 640130ORION 6401359. Flared or vented more than 1 hour (see instr.)0POLARIS 64016010. Pilot and Purge31,23811. Assist Gas0MCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)725,112Conservation:12. Fuel gas used in lease operations.693,754AOGCC Use OnlyAuthorization >1 hr:Safety:MCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONER18. Transferred to: (Express as a negative #)-21,859,067Comm. Comm.bfarouse@hilcorp.comForm 10-422 Revised 10/2021Block 6: Gas equivalent of NGLs &Propane;Block 12 includes 303 MCF of Propane, Block 15 includes 303 MCF of Propane Block 18: Includes MI Gas to Pt.McIntyre = 1,279,638 mscfI hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 9/20/2023Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.09.20 10:13:06 -05'00'Beth Farouse (909) HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTAugust 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE8/7/2023 0515:0535 120 Not required for events <= 1 hr Not required for events <= 1 hrTOTAL 120Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 120Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 31,238Assist 0TOTAL FLARED VOLUME 31,358 2. Facility NamePBU GC 2Percent78.0%2.3%8.6%8.7%2.5%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 10/19/202318. Transferred to: (Express as a negative #)-13,506,714Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)933,218Conservation:12. Fuel gas used in lease operations.586,559AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge30,1029. Flared or vented more than 1 hour (see instr.)0POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less316,557BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE September-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.10.19 10:10:45 -05'00'Beth Farouse (909) HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTSeptember 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL 0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE9/7/2023 0826:0925 316,557 Not required for events <= 1 hr Not required for events <= 1 hrTOTAL316,557Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 316,557exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 30,102Assist 0TOTAL FLARED VOLUME 346,659 2. Facility NamePBU GC 2Percent83.9%1.6%5.6%6.8%2.2%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 11/16/202318. Transferred to: (Express as a negative #)-19,468,506Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)676,464Conservation:12. Fuel gas used in lease operations.643,074AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge31,4639. Flared or vented more than 1 hour (see instr.)1,522POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less405BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE October-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.11.17 14:57:20 -06'00'Beth Farouse (909):&%Waste:08/16/2024JLC 8/15/2024 HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTOctober 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE10/29/2023 2311:2316 56 Not required for events <= 1 hr Not required for events <= 1 hr10/29/2023 2330:2359 16110/30/2023 0000:0030 188TOTAL405Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE10/7/2023 0327:0840 1,522 See Attachments See AttachmentsTOTAL1,522Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 405Unplanned Events > 1 Hour 1,522Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 31,463Assist 0TOTAL FLARED VOLUME 33,390         ,&**            !"## $    !   5  8  ' " " #          ,*-)  %&  @ -& ') @ -  %&   -& ( %"  # C&)     #%& ' -&  'A ( 0 12 & 34+56 ,&** >   ##94 *. ' 2. Facility NamePBU GC 2Percent84.4%1.3%5.8%5.9%2.6%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 12/15/202318. Transferred to: (Express as a negative #)-20,661,760Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)745,078Conservation:12. Fuel gas used in lease operations.711,043AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge30,6719. Flared or vented more than 1 hour (see instr.)0POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less3,364BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE November-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2023.12.19 16:00:05 -06'00'Beth Farouse (909) HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTNovember 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE11/6/2023 1100:1122 489 Not required for events <= 1 hr Not required for events <= 1 hr11/9/2023 1858:1925 2,25011/10/2023 0018:0030 625TOTAL3,364Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 3,364Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 30,671Assist 0TOTAL FLARED VOLUME 34,035 2. Facility NamePBU GC 2Percent85.2%1.5%6.0%4.9%2.3%19. Remarks:Title:Form 10-422 Revised 10/2021I hereby certify that the foregoing is true and correct to the best of my knowledge. Revision? Date of Revision:Authorized Name and Digital Signature with Date:Contact Phone:(713) 289-2627Note:All volumes must be corrected topressure of 14.65 psia and to a temperature of60° F. Authority 20 AAC 25.235.Contact Email:Production AnalystBeth Farouse 1/16/202418. Transferred to: (Express as a negative #)-21,728,309Comm. Comm.bfarouse@hilcorp.comMCF15. NGL Gas Equivalent0Waste: MCF16. Purchased gas0Reviewed by:17. Transferred from: CGF & FS10COMMISSIONERMCF13. Other (see instructions)0Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)760,756Conservation:12. Fuel gas used in lease operations.728,953AOGCC Use OnlyAuthorization >1 hr:Safety:11. Assist Gas010. Pilot and Purge31,8039. Flared or vented more than 1 hour (see instr.)0POLARIS 640160AURORA 6401208. Flared or vented 1 hour or less0BOREALIS 640130ORION 6401350290000032 PBU - WOA HILCORP NORTH SLOPE December-2023Disposition Volume MCF20.For production from multiple pools, list contribution of each pool as a percent ofTotal Volume.6. Sold0Pool Name Pool Code7. Reinjected0PRUDHOE 640150STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITION1. Facility Number 3. Field 4. Operator 5. Month/Year of DispositionForm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in DuplicateDigitally signed by Beth Farouse (909)DN: cn=Beth Farouse (909)Date: 2024.01.18 09:52:41 -06'00'Beth Farouse (909) HILCORP ALASKAPRUDHOE BAY UNIT - GC-2GAS FLARING AND VENTING INCIDENT REPORTDecember 2023Unplanned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Unplanned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0Planned events less than or equal to 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSENot required for events <= 1 hr Not required for events <= 1 hrTOTAL0Planned events greater than 1 hourDATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSESee Attachments See AttachmentsTOTAL0 TOTALUnplanned Events < 1 Hour 0Unplanned Events > 1 Hour 0Planned Events < 1 hour and not 0exceeding 5,000 MCFPlanned Events > 1 hour or 0exceeding 5,000 MCFPilot Purge 31,803Assist 0TOTAL FLARED VOLUME 31,803