Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAbout186-021Image Project Well History File Cover Page
XHVZE
This page identifies those items that were not scanned during the initial production scanning.
They are available in the original file, may be scanned during the rescan activity or are viewable
by direct inspection of the file.
...t ~:~ ~ - O ~. J Well History File Identifier
Organization (do.e) n
RESCAN
Color items:
Grayscale items:
Poor Quality Originals:
Other:
DIGITAL DATA
Diskettes, No.
Other, No/Type
O,A PAG S: I L.J- . NO ES.'
ORGANIZED BY: BEVERL~R. EI~E VINCENT SHERYL MARIA LOWELL
Project Proofing
OVERSIZED (Scannable)
[3 Maps:
Other items scannable by
large scanner
OVERSIZED (Non-Scannable)
Logs of various kinds
Other
DATE: ~)l I..~ I~__ /SI ~
illllilllllllllllll [] Staff Proof
By: Date:
PROOFED BY: BEVERLY BREN VINCENT SHERYL MARIA LOWELL DATE:
~si
PAGES: ] ~ (at the time of scanning)
SCANNED BY: BEVERLY BREN VINCEF~~MARIA
LOWELL
ReScanned (done)
RESCANNEDBY: BEVERLY BREN VINCENT SHERYL MARIA LOWELL
General Notes or Comments about this file:
DATE: la/
Quality Checked (done)
Rev1 NOTSc~noed.wpd
Memorandum
To: Well File:
Re:
State of Alaska
Oil and Gas Conservation Commission
Cancelled or Expired Permit Action
EXAMPLE: Point McIntyre P2-36AXX API# 029-22801-95
This memo will remain at the from of the subject well file.
Our adopted conventions for assigning APl numbers, permit numbers and well names did not
specifically address expired or cancelled permits. This omission has caused some inconsistencies in
the treatment of these kinds of applications for permit to ddil. Operators have asked us to adopt
formal procedures for this class of permit application in order to prevent future database disparities.
If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain
unchanged. The APl number and in some instances the well name reflect the number of preexisting
reddlls and or multilaterals in a well. In order to prevent confusing a cancelled or expired permit with
an active well or multilateral these case sensitive well identifiers will be changed for expired and
cancelled applications for permits to ddll.
The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95.
The well name for a cancelled or expired permit is modified with an appended xx.
These procedures are an addendum to the APl numbering methods described in AOGCC staff
memorandum "Multi-lateral (weilbore segment) Ddiling Permit Procedures, revised December 29,
1995.
AOGCC database has been changed to reflect these changes to this permit.
Statistical Technician
January 15, 1986
Mr. T. P. Oostermeyer
Regional Drilling Engineer
ARCO Alaska, Inc.
P. O. Box 100360
Anchorage, Alaska 99510-0360
Re: Prudhoe Bay Unit 4-19
ARCO Alaska, Inc.
Permit No. 86-21.
Sur. Loc. 916'FSL, 258'FWL, Sec. 26, TllN, R15E, IR,{.
Btmhole Loc. 1213'FNL, 2590'FWL, Sec. 23, TllN, R15E, UM.
Dear Mr. Oostermeyer:
Enclosed is the approved application for permit to drill the
above referenced well.
The permit to drill does not indemnify you from the probable need
to obtain additional permits required by law from other
governmental agencies prior to commencing operations at the well
site.
To aid us in scheduling field work, please notify this office 24
hours prior to commencing installation of the blowout prevention
equipment so that a representative of the Commission may be
present to witness testing of the equipment before the surface
casing shoe is drilled. Where a diverter system is required,
please also notify this office 24 hours prior to commencing
equipment installation so that the Commission may witness testing
before drilling below the shoe of the conductor pipe.
V~r~ruly yo~u?s,
C. V. ChattertOn~
Chairman of
Alaska Oil and Gas Conservation Commission
BY ORDER OF THE CO~ISSION
d!f
Enclosure
cc: Department of Fish & Game, Habitat Section w/o encl.
Department of Environmental Conservation w/o encl.
Mr. Doug L. Lowery
ARCO Alaska, Inc.
Post Office b,~x 100360
Anchorage, Alaska 99510-0360
Telephone 907 276 1215
January 10, 1986
Mr. C. V. Chatterton
Commissioner
State of Alaska
Alaska Oil & Gas Conservation
Commission
3001 Porcupine Drive
Anchorage, AK 99501
SUBJECT: DS 4-19, Permit to Drill
Dear Mr. Chatterton'
Enclosed are'
An application for Permit to Drill DS 4-19, along wi th
a $100 application fee
Diagrams showing the proposed horizontal and vertical
projections of the wellbore
o Proximity plots
A diagram and description of the surface hole diverter
system
o A diagram and description of the BOP equipment
Since we estimate spudding this well on January 22, 1986, your
earliest approval will be appreciated. If you have any questions,
please call Gregg Walz at 263-4541.
Sincerely,
K. M. Le
Regional Drilling Engineer (Acting)
KML/GSW/mh
PD2/L20
Enclosures
ARCO Alaska, Inc. is a Subsidiary of AtlanticRichfieldCompany
la. Type of work.
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION
PERMIT TO DRILL
20 AAC 25.005
2. Name of operator
ARCO Alaska, Inc.
I
DRILL [~ I lb. Type of well EXPLORATORY []
REDRILL [] I DEVELOPMENT OIL []
DEEPEN [] DEVELOPMENT GAS []
SERVi,,CF_~, r~I STRAT GRAPHIC
SINGLE ZONE
MULTIPLE ZONE
3. Address
P. 0. Box 100360, Anchorage, Alaska 99510
4. Location of well at surface
916' FSL, 258' FWL, Sec.26, T11N, R15E, UN
At top of proposed producing interval
1320' FNL, 2560' FWL, Sec.23, T11N, R15E, UN
At total depth
1213' FNL, 2590' FWL, Sec.23, T11N R15E, UN
5. Elevation in feet (indicate KB, DF etc.) 6. Lease designation and serial no.
RKB 62', PAD 22' GL ADL 28323 ALK 2321
12. Bond information (see 20AAC25.025) Federal Insurance Company
Type Statewide Surety and/or number #8088-26-27
9. Unit or lease name
Prudhoe Bay Unit
10. Well number
4-19
11.Fieldandpool
Prudhoe Bay Field
Prudhoe Bay 0il Pool
Amount $500,000
13. Distance and direction from nearest town
6 mi. NE of Deadhorse miles
16. Proposed depth (MD & TVD)
13143 'MD, 8743 ' TVD feet
19. If deviated (see 20 AAC 25.050)
KICK OFF POINT 1500 feet.
21
14. Distance to nearest property or lease line
1320' 8 Target feet
17. Number of acres in lease
2560
20. Anticipated pressures
MAXIMUM HOLE ANGLE 55 o (see 20AAC25.035(c) (2)
Proposed Casing, Liner and Cementing Program
15. Distance to nearest drilling or completed
4-24 well 30' @ 2250~ feet
18. Approximate spud date 01/22/86
2945 psig@_ 80°F Surface
3950 psig@ 8743 ft. TD (TVD)
SIZE
CASING AND LINER
SETTING DEPTH
QUANTITY OF CEMENT
Hole
30"
17-1/2"
12-1/4"
8-1/2"
Casing Weight
20" 91.5#
13-3/8" 68.0#
72.0#
9-5/8" 47.0#
7" 29.0#
Grade Cou
H-40
K-55
L-80
L-80
L-80
ARCO Alaska.
22. Describe proposed program:
piingI Length
Wel ~ 80 '
BTC/ 41 '
BTC/ 2496 '
BTC/ 12681 '
BTC/ 725 '
Inc., proposes
MD TOP TVD
40' I 40~
39' I 39'
80' I 80'
37' I 37
I
12418' I 8332
to drill thi
(include stage data)
MD BOTTOM TVD
120' I 120' 2000# Poleset
80' 80' 2500 sx CS III &
2535'I 2500' 400 sx Class G
' 12718' I 8502' 500 sx Class G
' 13143'I 8743' 300 sx Class G
s Sadlerochit injector well to 13,143'MD
(8743'TVD). Logs will be run across selected intervals. A string of 4-1/2", 12.6#, Lo80 tubing, packer, and
necessary provisions for subsurface safety equipment will be run. The packer will be set above the Sadlerochit.
A separate Sundry Notice will be submitted when the well is to be perforated. It is initially planned to pro-
duce the well for a period of time then convert it to its ultimate use as an injector. A 20", 2000 psi annular
diverter might not be used for the well. A waiver of the surface hole diverter system for Drill Site 4 has been
received from the AOGCC. A 13-5/8", 5000 psi, RSRRA BOP stack will be installed on the 13-3/8" surface pipe. It
will be tested to 5000 psi (3000 psi for annular) upon installation and weekly thereafter. Reserve pit fluids
will be disposed of down the 9-5/8" x 13-3/8" annulus. The annulus will be left with a non-freezing fluid during
any extended interruption in the disposal process. The annulus will be sealed with 300 sx of cement followed by
Arctic pack upon completion of the fluid disposal process. The following wells are within 200': DS 4-24 30' ~
2250'MD; DS 4-18 52' ~ 1550'MD; DS 4-23 112' @ 2643'MD; DS 4-22 145' ~ 2483'MD; DS 4-16 183' @ surface.
23. I hereby certify that the foregoing is true and correct to the best of my knowledge
SIGNED ~f' ,,~-~ TITLE Regional Drlg Engr.(Acting) DATE
The space below for Commission use
Samples required
I--lYES E~NO
Permit number
APPROVED BY
Form 10~,01
Rev. 7-1-80
CONDITIONS OF APPROVAL
Mud log required Directional Survey required I APl number
[]YES ~NO [~YES E~]NO [ 50- d'b~t- %/._5'-.T _3
Approval date
¢~'L..~l J, ~ 01/~5~86 SEE COVER LETTER FOR OTHER REQUIREMENTS
/~/~/~~MISSIONER DATE January 15, 1986
~ '. A ~ ~~~ bY order of the Commission
(GS~[ CD2/PD20~/--/ / ' Submit in triplicate
lOOO
2000
3OOO
4000
5000
8000
7000
8OOO
9000
10000
D84-19
0 tO00 2000 3000 4000 5000 6000 7000 8000 9000 10000
,'U- L;AS~IN(. I VL.) =
(OP T¥1D = 1500
ARC 3 AL, SKA, INC.
7.5
2000
17.5 SHL:916',FSL, 258'FW.,
22.! 5 13-3/8' ~ASONG TV ) -- 2500 I~ID = 2535 DEP -- 230 SEC.26, r11N, RI§E, U
'~5~5~/; ~ THL: 1320' :NL, 2§§O'F~"L,
~-~.-~ ~E~. 32_ 711N: RI.~F_ II d 3000
4-7.5
52.5
:.oC TvD---3386 MD =3715 DEP-989
~~ 4000
5000
N 15 DEG 28 MINE
8636 FT(TO TARGET)
~,VERAGE AI~ GEE :'
55 DEG 22 IV IN
'"- 7000
K-10 TVD = 7412 ME = 10800 r)EP = 6819 ~'~
-...
K-5 TVD ---- 7887 MD-- 1638 DEP =7507
8000
9-~.,/8" CASINI; TVD = 8502 MD = 1:!718 OEP = 8398 ~~;_.
TOP 3ADLEROCI~0T TVD ---- ~!512 MD -- 12735 DEP = 8412
~/O CONT/,CT TVD-- ~647 MD = 12973 DEF --8607
TAP,~I~T TV~ = 8~87 N~ = 13~)~8 ~P = 8~3~ ~ooo
aAS~ SADLEROI:HIT TVD = 8687 MD = 13043 D;!P = 8665
TD TVD '= 8743JVID = 13143 DI-'P = 8746
............................................................................................ !0000
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
VERTICF:tL SECTION
6000
...... E - kl C00ROINRTES ,--
o-2000 -1 log 0 1000 2000 . O 4000 5000
SEC.2§, T 1N, R1fE, Ol~
THL: 1320' :NL, 2560'FVIL,
SEC.23, T 1N, R15E, Ol~
DSC-t9
87 TARGET
TVD -- 81 167'
TMD -- 1," 008'
DEP -. 81~ 36'
N 8324
E 2302
2973
o
0
~0
0
0
-2000 -1000 0 1000 2000 3000 4000 5000
E - ~ COORDINRTES
-' P. - FI COORDINRTES ....
-2000 -1000 0 1000 2000 5~o0 4000 5000
0
0
0
BSA-
0
0
0
725
-2000 -1000 0 1000 2000 3000 4000 5000
F. - N COORO]NATES
E - W COOROINB~£S
-300 -200 - 100 0 1 O0 _,~: 200 300 400
' ' ' ' ' ' ' ' ' ' / I I I il I I I I ,' ' t , ,
_
.................. ~ 2731
_. · ,~ ~58
............ ,
'1
,JAr 1 0 '~'~'~
~ -, , t . , . ,,, ,
A~aska Oil & gas Cons, C~rtmission
, ,, ,, , ~
-dO0 -300 -200 - 1 O0 0 1 O0 200 300 400
E N oooROINFtTES
SURFACE
HOLE DIVERTER SYSTEM
ARCO ALASKA ]:NC'.
SCHEMATIC
Icus.]~. I
_1
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
IO" HYD. OPH. BALL VALVE
¥~LL ~ ISEE: I~IAI~!
IO" HYD. OPR. BALL VALVE:
ALL 90' TUI:~IS AHE: "TEE"
I~E S£HVE
PIT
NOTE-
FL(ill. I1~:
DH ILL lNG
RIIER
~O' 2C)0(:) PSI Ill)
NMUI. Ni
Valves on diverter
lines open automati-
cally when the annular
preventer is closed.
ILL lNG
~PIXL
20'
I0' t4YDI~UL IC
GP~A~D BALL
'DETAIL"
~)Z6010~03
,
10.
~cc~n~ator Capaci~' Tes~
1. Check and fill accumllator reservoir to proper
l~el ~:h ~~ic ~d.
2. ~s~e ~: ~~tor p~s~e is 3000 psi
1500 psi ~t~~ of ~ relator.
3. ~se~e t~, :~n close ail ~:s
~ ~d ~ ~ ~ ~ss~ r~~ ~er
all ~ts a~ clos~ ~ ~r~
is ~5 s~ clos~g t~ ~
p~s~.
175/8" ~P St~ Tes:
1. Fill ~P s~ ~ ~ld ~ a ~-~z~
g. ~ :~t all ~ld ~ ~
~k ~g jo~ ~ p~te~ pl~ seat~g
~. ~ test plug ~ ~1
~. ~ose ~~ p~enter ~ ~s~e~ vales.
~. ~i~ly ~es: ~s.
-5. -In e~ of ~ ~11~ :esM, fir~ ~ld a 250 psi
:e~ at ~ ~ ~s~.
6. I~~ ~s~ ~o ~000 psi
of 3~es. Bi~ ~es~ to ze~.
~. ~ ~ ~~er ~ clue ~ ~t of pi~
r~. I~ ~~ ~o 5000 psi ~ ~ld for at
8. ~o~ valves ~ly ~m of ~s ~ ~n
~s. I~~ ~s~ ~o 5000 psi ~ ~ld for
at le~ 3 ~s. Bl~~s~ ~o ze~.
~ ~ set of pi~ ~ ~ close
pi~ rm. ~e ~s~ ~o 5000 psi ~1~
Tes: ~g~es~ ~old valves
~ 50~ psi ~~ of v~ ~ ze~ p~s~e
BI~ ~s~ to ~. ~ ~
r~.
~ offf ~ jo~ ~~1 ~ o[ ~le. ~ose
bl~ ~ ~ :~ ~o 50~ psi
~es.
BI~ ~s~ o~ all ~~.
~ ~~ld ~ l~s ~
~z~ li~d ~ all v~ves ~ set m ~l~g
Test s:~i~ valVes :o 5000 psi.
Tes~ ~lly c~ ~ ~i~ ~P
~ ~ra:ion of
~m. Si~ ~ s~ ~o ~ill~g ~isor.
Pe~ ~lete ~ te~ ~ a ~k
:z.
14.
9
Ravised 2/21/8~
ARCO Alaska, Inc. ·
Post Office b~,~ 100360
Anchorage, A~aska 99510-0360
Telephone 907 276 1215
November 7, 1985
Mr. C. V. Chatterton
Commi ss i oner
State of Alaska
Alaska 0il & Gas Conservation
Commission
3001 Porcupine Drive
Anchorage, AK 99501
SUBJECT' Conductor As-Built Location Plat - DS 4
(Wells 19, 25 - 28, 33)
Dear Mr. Chatterton'
Enclosed is an as-built location plat for the subject wells.
you have any questions, please call me at 263-4944.
Sincerely,
J. Gruber
Associate Engineer
JG/tw
GRU12/L79
Enclosure
If
RECEIVED
A)aska Oi) & Gas Cons. Commission
AnchoF2F.)e
ARCO Alaska, )nc. is a Subsidiary o( AHanticRich(ie)dCompany
· I0
· 9
· 8
· ?
· 6
o 5
· 4
· 2
o I
20 ·
21 ·
22 ·
~4 ·
II ·
$0 o
TH
Grid North is 13°38'East
Cond ASP ZONE 4
COORD~ATES
19 Y = 5 952 791.73
X = 713 057. 60
33 Y = 5 952 558.46
X = 713 II4.53
2~ Y = 5.95~ 092.0~
X = 713 227. 65
26 Y:5 951 575.43
X'- 713 ~,,5.~9
'-X I T,.
I" = 4000'
VICINITY MAP
SECTION OFFSETS
WLO SLO
WITHIN SECTION 26
I. AT = 70° 16'264359' 254
LONG = 148°16'$5. 2442"
LAT = 70° 16'24.1266" 304
LONG = 148° 16' 33. 7795"
L.AT = 70o16, 19. 5094" 404
LONG = 148° 16' 30. 8718"
LAT = 70016, 18.3.552" 429
LONG = 148016' 30. J4,3,3"
913
678
208
91
WITHIN SECTION 35
27 Y :5 951 858', 74 LAT :70°16'17.2.001''
X: 715 284.2.5 LO/VG '-148°16'29 4172
28 Y :5 951 742.10 LAT= 70°16'16.0455
X = 7/3 312.58 LO,%'G=I48°I~'28.68~9
WLO NLO
453 26
478 144
CERTIFICATE OF SURVEYOR
I HEREBY CERTIFY THAT ! AM PROPERTY REGISTERED AND
LICENSED TO PRACTICE LAND SURVEYING IN THE STATE OF
ALASKA AND THAT THIS PLAT REPRESENTS A LOCATION
SURVEY MADE BY ME OR UNDER MY DIRECT SUPERVISION,
AND ALL DIMENSIONS AND OTHER DETAILS ARECOi~.~:~Tc
DA~'E w SURVEYOR
LEGEND
WLO ' WEST LINE OFFSET
SLO - SOUTH LINE OFFSET
NJ,,.~ ." NORTH LINE OFF:SET
Q~,
~ . THIS SURW_Y.
ARCO NO.
I
ARCO Alaska , Inc.
AS- BUILT
DRILL SITE 4 CONDUCTORS
LOCATED IN PROTRACTED
SECTIONS 26 & 35, TIIN, RI5E U.M.
PREPARED BY
LOUNSBURY 1~ ASSOCIATES~ INC.
723W6th AVF_~ ANCHORAGE,ALASKA
,DATE: 10/29/~5
CHKD. BY: GEL
I I"
SCALE: = 400'
FL D. BI(.: LHO 85'101
i~r
r '
Company /3 ~..
Lease & Well No.
ITEM APPROVE DATE
(1) Fee
(2) Loc
(3) Admin ~ /-/~ L 9.
(9 'thru 12) 10.
(10 and 1~2)/ 12.
(4) Casg ~Q-'~
(13 thru
,~zi ~'
(22 thrd 26)
Geology: En g ~b3ec~r in g:
WVA ~HJH ~ ~
JAL
rev: 03/13/85
6.011
1. Is the permit fee attached .........................................
2. Is well to be located in a defined pool ..........
4. Is. well located proper distance from other wells ...... · . .."
5. Is sufficient undedicated acreage available in this pool ....... ...
6. Is well to be deviated and is wellbore plat included. ..... ...''' i i
7. Is operator the only affected party ................. · .......
8. Can permit be approved before ten-day wait .........................
13.
14.
15.
16.
17.
18.
19.
20.
21.
YES NO
22.
23.
24.
25.
26.
27.
Does operator have a bond in force ..................................
Is a conservation order needed ......................................
Is administrative approval needed ...................................
Is the lease number appropriate .....................................
Is conductor string provided ...' ................... . .
Is enough cement used to circulate ~n cond~o~ and ;~fa~e'ii.i.il
Will cement tie in surface and intermediate or production strings .
Will cement cover all known productive horizons .............
Will surface casing protect fresh water zones .... i. iiii.i ....
Will all casing give adequate safety in collapse, tension and burst
Is this well to be kicked off from an existing wellbore ...........
Is old wellbore abandonment procedure included on 10-403 ..........
Is adequate wellbore separation proposed ...........................
Is a diverter system required .......................................
Are necessary diagrams of diverter and BOP equipment attached .......
Does BOPE have sufficient pressure rating - Test to ~/dr~ psig ..
Does the choke manifold comply w/API RP-53 (Feb.78) ..................
Is the presence of H2S gas probable .................................
Additional requirements .............................................
H ~ T -< u lZ,,V / 7'7"£ 0
INITIAL " GEO. UNIT ON/OFF
POOL CLASS STATUS AREA NO. SHORE
¸.