Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
HOME
EVENTS
DATA
Data List
Drilling
Production
Orders
Data Miner
Document Search
REPORTS
Reports and Charts
Pool Statistics
FORMS
LINKS
Links
Test Notification
Data Requests
Regulations
Industry Guidance Bulletins
How to Apply
ABOUT US
History
Staff
HELP
Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
185-298
Image Project Well History File Cover Page XHVZE This page identifies those items that were not scanned during the initial production scanning. They are available in the original file, may be scanned during the rescan activity or are viewable by direct inspection of the file. RESCAN DIGITAL DATA OVERSIZED (Scannable) n Color items: n Diskettes, No. n Maps: D Grayscale items: n Other, No/Type [] Other items scannable by large scanner [] Poor Quality Originals: OVERSIZED (Non-Scannable) ~' Other: [] Logs of various kinds Other TOTAL PAGES: ~CJ ORGANIZED BY; ~REN Project Proofing NOTES: VINCENT SHERYL MARIA LOWELL [] Staff Proof By: Date: PROOFED BY: BEVERLY E~REN VINCENT SHERYL MARIA LOWELL DATE: /si Scanned (done) PAGES: / SCANNED BY; (at the time of scanning) BEVERLY BREN VINCE~ARIA LOWELL RESCANNEDBY; BEVERLY BREN VINCENT SHERYL MARIA LOWELL General Notes or Comments about this file: /'O/~ -~/~ ~'- / PAGES: / ~ DATE: ~si Quality Checked (done) RevlNOTS~anned.wpd Memorandum To: Re: State of Alaska Cancelled or Expired Permit Action EXAMPLE: Point McIntyre P2-36AXX API# 029-22801-95 Oil and Gas Conservation Commission This memo will remain at the front of the subject well file. Our adopted conventions for assigning APl numbers, permit numbers and well names did not specifically address expired or cancelled permits. This omission has caused some inconsistencies in the treatment of these kinds of applications for permit to ddii. Operators have asked us to adopt formal procedures for this class of permit application in order to prevent future database disparities. If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain unchanged. The APl number and in some instances the well name reflect the number of preexisting reddlls and or multilaterais in a well. In order to prevent confusing a cancelled or expired permit with an active well or multilateral these case sensitive well identifiers will be changed for expired and cancelled applications for permits to ddll. The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95. The well name for a cancelled or expired permit is modified with an appended xx. These procedures are an addendum to the APl numbering methods described in AOGCC staff memorandum "Multi-lateral (weilbore segment) Ddlling Permit Procedures, revised December 29, 1995. AOGCC database has been changed to reflect these changes to this permit. e MCMains ' t Statistical Technician Unocal Oil & Gas Division Unocal Corporation P.O. Box 190247 Anchorage, Alaska 9951~-~,~,~7 Telephone (907) 276-7600 UNOCAL Enwronmental Group Alaska District February 6, 1986 Hr. C.V. Chatterton AK. Oil & Gas Conservation Comm. 300i Porcupine Drive Anchorage, Alaska 99501 Dear Mr. Chatterton: SUNDRY NOTICE INTENTIONS Attached for your approval are three (3) coples each of a Sundry Notice of Intention for KTU 42X-6, KBU 12X-8, Kenal Gas Fleld& D-29RD, Trading Bay Unlt. Work on D-29RD ls expected to commence as early and February 10th therefore, we would appreciate approval as soon as possible. Very truly yours, Roberts Environmental Specialist tj/O124n Attachments RECEIVED F E 8 0 6 1586 Alaska Oil & Gas Cons. L;ommlssion Anchorage STATE OF ALASKA ALASKA Olt_ AND GAS CONSERVATION C~MISSION SUNDRY NOTICES AND REPORTS ON WELLS 1. DRILLING WELLx COMPLETED WELL [] OTHER [] 2. Name of Operator 7. Permit No. UNION OIL COMPANY OF CALIFORNIA (UNOCAL) 85-298 3. Address 8. APl Number PO BOX 190247 ANCHORAGE AK 99519-0247 5o- 133-20386 9. Unit or Lease Name Kenai Beluga Unit 4. Location of Well 347' S & 783' W of NE Cor., Sec. 7, T4N, RllW, SM. 5. ElevatIon in feet (indicate KB, DF, etc.) 100' KB MSL 6. Lease Designation and Serial No. A-028142 10. Well Number KBU 12X-8 11 Field and Pool Kenai Gas Field 12. (Submit in Triplicate) Perforate L-~ Alter Casing [] Perforations Stimulate [] Abandon [] Stimulation Repair Well [] Change Plans [] Repairs Made Pull Tubing [] Other [] Pulling Tubing (Note Reportmultlplecompletlonson Form 10-407 with a submitted Form 10-407 for each completion.) Check Appropriate Box To Indicate Nature of Notice, Report, or Other Data NOTICE OF INTENTION TO: SUBSEQUENT REPORT OF: (Submit in Duplicate) [] Altering Casing [] Abandonment [] Other 13. Describe Proposed or Completed Operations (Clearly state all pertinent details and g~ve pertinent dates, ~ncluding estimated date of starting any proposed work, for Abandonment see 20 AAC 25.105-170). Drilling and Completion fluids will be disposed of down the 9-5/8" X 13-3/8" annulus; 2000' ~ below the 13-3/8" casing shoe. 14. I hereby certify that the foregoing ~s true and correct to the best of my knowledge. Signed Roberts 5 T,tle ENVIRONMENTAL SPECIALIST The space below for Commission use Date 02106/86 Conditions of Approval, ~f any. Approved by By Order of COMMISSIONER the Commission Date Form 10-403 Rev. 7-1-80 Submit "Intentions" m Triplicate and "Subsequent Reports" ~n Duplicate December 20, 1985 ~r. Roy D. Roberts Environmental Technician Union Oil Company of California P. O. Box 6247 Anchorage, Alaska 99502-0247 Re: Kenai Beluga Unit 12X-8 Union Oil Company of California Permit No. 85-298 Sur. Loc. 347'.S, 783'W of NE cr Sec. 7, T4N, R!IW, SM. Btmhole Loc. 2050'S, 250'E of ~-~,7 cr Sec. 8, T4N, R1].W, SM. Dear Mr. Roberts: Enclosed is the approved application for permit to drill the above referenced well. The permit to drill does not inderanify you from the probable need to obtain additional permits required by law from other governmental agencies prior to commencing operations at the well site. To aid us in scheduling field work, please notify this office 24 hours prior to commencing installation of the blowout prevention equipment so that a representative of the Commission may be present to witness testing of the equipment before the surface casing shoe is drilled. ~.Vhere a diverter system is required, please also notify this office 24 hours prior to commencing equipment installation so that the Commission may witness testing before drilling below the shoe of the conductor pipe. Ver~y? tru~~rs~: ~ C. V. Chttt~rffon Chairman of Alaska Oil and Gas Conservation Commission Eno losure cC: Department of Fish & Game, Habitat Section w/o encI. Department of Environmental Conservation w/o encl. Mr. Bill H. Lamoreaux Unocal Oil & Gas Divisio' Unocal Corporation ~ RO. Box 190247 Anchorage, Alaska 99519-0247 Telephone (907) 276-7600 UNOCAL Environmental Group Alaska District December 13, 1985 Mr. C.V. Chatterton Ak. Oil & Gas Conservation Commission ~001 Porcupine Drive Anchorage, Ak. 99501 Dear Mr. Chatterton' PERMIT TO DRILL KBU 12X-8 Attached, for your further handling, are three (3) copies of the revised first page of the permit to drill for KBU 12X-8. In reply to Mike Mender's question regarding the close proximity of wells, Union 0il will be running an MWD tool which will also be checked with single shot surveys until all existing wells are passed. In addition, for greater accuracy in the upper portion of the hole, a 1" = 50' scale directional map will be used rather than 1" = 200'. If you have any further Questions, please give me a call. Very truly yours, Environmental Department cwl attachment cc: Lucian Abernathy STATE OF ALASKA ALASKA-~,L AND GAS CONSERVATION Ct>-w~iMISSION I ERMIT TO DRILL 20 AAC 25.005 la. Type of work. DRILL [] lb. Type of well EXPLORATORY [] SERVICE [] STRATIGRAPHIC [] REDRILL [] DEVELOPMENT OIL [] SINGLE ZONE [] DEEPEN [] DEVELOPMENT GAS [] MULTIPLE ZONE [] 2. Name of operator UNION OIL COMPANY OF CALIFORNIA 3. Address PO BOX 6247, ANCHORAGE, ALASKA 99502 4. Location of well at surface 9. Unit or lease name 347'S & 783' W off NE Cor., Sec. 7, T4N, RllW, SM. Kenai Beluga Unit At top of proposed producing interval 10. Well number 1580'S & 20' E of NW Cor., Sec. 8, T4N, RllW, SM. KBU 12X-8 At total depth 11. Field and pool 2050'S & 250'E of NW Cor., Sec. 8, T4N, RllW, SM. 5. Elevat,on ,n feet (indicate KB. DF etc.) I 6. Lease designation and serial no. Kenai Gas Field 100' KB, MSLI A-028142 12. Bond,nformat,on (see 20 AAC 25,025) Natlonal Fire Insurance Company off Type Statewide Surety and/or number Hartford (B5534278~ Amount 13. D~stance and direction from nearest town 14. Distance to nearest pr~)perty or lease line 15. Distance to ne,~rest drilling Or completed ~ MilP_,_s_Sou~_cLf~ Kenaim'les -~-~nn ' feet wel~RII 1 -~_~R 900 ' feet 16. Proposed depth (MD & TVD) 17. Number of acres ~n lease 18. Approximate spud date 7300'MD & 6900'TVD feet 2560 Jan. 15, 1986 19. If deviated (see 20 AAC 25.050) 120. Anticipated pressures 2790 ps,g@ Surface KICK OFF POINI~00 ' feet. MAXIMUM HOLE ANGLE 20 oI (see 20 AAC 25.035 (c) (2) 3450 _ps,g@ ~c)l"10' ft. TD (TVD) 21 Proposed Casing, Liner and Cementing Program SIZE CASING AND LINER SETTING DEPTH QUANTITY OF CEMENT Hole Casing Weight Grade Coupling Length MD TOP TVD MD BOTTOM TVD (include stage data) 20" 94# K-55 ~elded 200' Surf I --- 200' i 200' Driven to refusal ' I ~ I ~ 200 ' .7-1/2"13-3/8" 61# K-55 ~utt 2000' Surf. ' .... .~100' I 2000' 1400 sxs cl "g" ,2-1/4" 9-5/8" 47# N-80 lutt 7300' Surf. ~ .... ~300' I 6900' 2200 sxs cl "G" I I 22. Describe proposed program: PROPOSED PROGRAM '1.)' Move i'n and rig dp on pad 41-7. 2.) Drive 20" casing to refusal ~ 200' MD & install 10" diverter lines. 3.) Drill 17 1/2" hole to 2100' MD. 4.) Run and cement 13 3/8" casing at 2100' MD (2000' TVD). ~ ~CF~ 5.) Install and test BOPE to 3000 psi. 6.) Drill 12 1/4" directional hole to 7300' MD. 7.) Run logs. 8.) Run and cement 9 5/8" casing to 7300' MD. Alaska 0ii & Gas 9.) Test the Beluga gas sands as directed. 10.) Complete well as a dual Beluga completion. ~ 23.1 hereby ce~~reg~j.~2~j.is~sue~j~rect to the best of my knowledge SIGNED _ Roy D~ Roberi~s ~.~ TITLE ENVIRONMENTAL SPECIALIST DATE 12/13/85 The space below for Commission use CONDITIONS OF APPROVAL Samples required Mud log required Directional Survey required I APl number OYES .JZ].N O []]YES "J~rN O [~YES •NOI 50-133-20386 Permit number Approval date 85-29~ ~ ....-'-) 1_2/20./8~ I SEECOVER LETTER FOROTHEP APPROVED OMMISSIONER DATE December 20. 1 ~k~-- 2 -/~ ~ ..'~//~~~ by order of the Commission Form 10401 :ate Rev. 7-1-80 Unocal Oil & Gas Divisiq .... Unocal Corporation ~. P.O. Box 190247 Anchorage, Alaska 99519-0247 Telephone (907) 276-7600 UNOCAL Environmental Group Alaska D~stnct December 4, 1985 Mr. C.V. Chatterton AK. Oil & Gas Association 3001 Porcupine Drive Anchorage, Alaska 99501 Dear Mr. Chatterton: Attached for your approval are 3 copies of the Permit to Drill application for KBU 12X-8, Kenai Gas Field along with check number 19386 to cover the required filing fee. Please return the approved Permit to the undersigned. Very truly yours, Lawrence O. Cutting ENVIRONNENTAL SPECIALIST tj/OO91n Attachments STATE OF ALASKA ALASKA ~- AND GAS CONSERVATION CC~_.MlSSlON PERMIT TO DRILL 20 AAC 25.005 la. Type of work. 2. Name o~perator DRILL REDRILL DEEPEN lb. Type of well EXPLORATORY [] DEVELOPMENT OIL [] DEVELOPMENT GAS.~ SERVICE [] STRATIGRAPHIC SINGLE ZONE [] MULTIPLE ZONE · PO BOX _62~_, ANCHORAGE, ALASKA 99502 jCl" -~] L o'~a t ~ o-n~ I a t ~r~-a~ ..... 19. Unit op-[~ase name +347 S & +78~ W of NE Cor., Sec. 7, T4N, Rll~, SN. ~ Ke~i Beluga Unit A~op of propose~produ~ng interval I 10. ~ell number +l~80'S & ~0' ~of N~ Cor., Sec. 8, T4N, Rll~, SN. ~ ~BU 12X-8 A~otaldepth -- ~ / 1~ Fleldand pool +2050'S & Z2_~g'E oP~ Cor., Sec. 8, T4N, RllW, SM. [/, ~~~e KB. DF etc:t 6. Lease designat,on and serial no. ~ Kenai Gas Field + z00, 'xl ~r~~© AAC 25,025~% National Fire Insurance Co~¢ny o~ TVp~ Statewide Sur.W~d/or.umb~r Hartford (B55~4278~ ' Amo..t $200,000.00 13. D,stanceanddlrectlon from nearest town I~ 14. Dlstanceto nearest propertyor leasCne 115. Distance to nearest drilling or completed mz s sou h orK~na~,,- I% // feet I well KBU 1~-8 ~00I feet ~ ~F~~D-~- I ~7. Number of acres in lease ~ 18. Approximate spud date +7300'ND & +6900'TVD feet I ~ 25~0 ." , [ 5an. 02, ~986 20. Anticip.~ted pressures KICK OFF POINT +500' feet. MAXIMUM HOLE ANGLE 20 o (see 20AAC25.035(c) (2) 19. If deviated (see 20 AAC 25.050) +2790 psig@ , Surface '~3ZI.50 psig@._.('2~_0_Q_$t. TD (TVD) Proposed Ca.~ng, Liner and Cementing Program SIZE CASING AND LINER ~ SETTING DEPTH QUANTITY OF CEMENT Hole I Casing We,ght Grade Coupl,ngI LengthX ~ TOP TVD MD BOTTOMTVD (include stage data) ~0" 94# K-55 Welde~ +20~ 7'SuCff! l, ___ +200''1 +200 Driven to refusal [ . I- % '.t." , - I e +200' . iT_] /~,,l~_z/~ ,, Ali;~ ~_~s I+?nn0'~ .A~r¢, ___- ~2ioo~ +200[ + 1400 sxs cZ "G" ]~_~)~,,-~_~,, ~ ~-~ ~(( ~ ~00; /~'rf., .... ~00~ %~90(' % 2200 sxs cl "G" 22. Describe propo~ I prog ~m: / ' ~ PROF QSE~ PROGR~M/ y'~ ~.; ~oQe &n an~ ~g up on p~d 4~-7. 2.) D~ve 20" cas&rig to =~usa~ e ~ 200' MD & &nsta~ &0" d~ve=te= ~&nes. 3.) B=&~ ~7 ~/2" ho~e ~¢ + 2~00' MD. 4.) Run and cement &3 3/8"~as&ng at + 2~00' MD (+ 2000' TVD). 5.) Znsta~ and test ~PE ~o_3000 ps&% -- 6..) Drill 12 1/4" di~ctional hole to_+ 7300"MD. r~. _ ~ .... 8.) Run and cement9 5/8" casing to + 7300' HD. 9.) Test the De.ga gas sands as directed. _ . ~C 0 ~ ~~_omp_Zete w~l as a dual Beluga comp~etion.~~ 23. I hereby ce~,fy that the forego,n.g~ and~$?.~he~st of my knowledge ~ r % ~.lMsk~ 0il & Gas Cons S,GNEDLawzence 0. ¢0~g ~" T,TLE ENVZRONNENTA'~ SPECZALZS~A¢¢ch°~02/85 Samples required E~YES ~NO Permit number CONDITIONS OF APPROVAL Mud log required []YES [~NO Approval date D~rect~onal Survey required ~YES I-lNG APl number SEE COVER LETTER FOR OTHER REQUIREMENTS APPROVED BY ,COMM ISSI ON ER DATE by order of the Commission Form 10401 Rev. 7-1-80 Submit in triplicate KU 43-6 , KTU 1325 KU 43 6X KU 41-7 , 3~~q~ ,f tX KU 24-5 KBU 12-X8 43-6A ·\Tvo 4783 KBU-23X-6 MD 6950 e~ TVD 64,4.5 KTU-4$-6X TMD 8370 K U - 43 .:'6'A TMD 5300 KTU - 13-5 TM D 8232 TVD 7824 3 2 8 KU -14- TD 15,047 · |URF LOC. FOR KDU-8 MD 4390 KBU-31-7~, TMD 7750'ThA- Orig. hole KDU-4 TMD 5540 ii / ~DI3U-"7'4~ R..~:~:~f~.~/(J~ I M D 10,8 I O~ KU-24-7 I TMD 5820 ~ I~U-I TMD 9950 RECEIVED KU-24-5 =~~TMD 5900 ./ TVD 4965 2 3 4- z KDU-2(21- ~ TM D 10~620 I<U-I I-8 · * TM O 5364 · · · ~ TARGET"A" · Q TOP BELUGA: · 5130~ MD '% 4730' VD '~) .... K S U _1__2 X-8_ BHL: 250~ FW.L. & 2050~ F.N.L. 7410' TMD .... 6900'TVD KBU-13-8 TM D 8770 KUH-1 {14X-8) 5 KU-43-7 ~-TMD 5700 TMD 14,72 I 13 T V D 14,403 KU-I 1-17 "~~T M D 5400 TVD 4856 1-18 (KUH-I) .IL i ii i i i ii ii ii ung®n Alaska District -- Alaska Oil & 6~s Cons, Coi~missi( 0 500 I00~ FEET KENAI GAS FIELD PROPOSED WELL LOCATION I% load KBU 12X-8 APRIL 17, 8'.. .'. ij//t~ ~ .~ / .J ~-, ~. ~'/ ~-~ ~ . ........................... j o VERTICAL SECTION ......................... '[ ......... IJNIOH OIL COMPANY OF CALIFORNIA 0.50 I-K. 0.~.--500', ~ ............ KSU ~2X-8 I ' i , ~ ~ ~ADIIJS OF CtJFtVATU~E BuJl'd 2.5j/~00' L ;~ELL PROPOSAL · t.oo W ......F ............. T ......: ........ i-'- I~ I J [ ' ~ SCALE : ~ inch ~. 50 ........................ ~ ......... ~ ........~ .... ....... r ....... [ ......... , ......... i ....... ; ................... r ............... ; J ' ' O' t ' I ', ~.oo ~ X ,Average~ng]~.~. ~_ .......... L ........... L ......... ~ ........ I 3. SO ~ .... ! : ......... ~ ...... ; ........... I 'T 4.oo ' ~ _ ....... : .......... L ........ T ~ D 4730 ~ ~ T.M.D. 4955 ~arget "A" ~ V 4.5o Dep. 1357 ToR Beluga F6rmati6n ...... , ........ ~ ........~ .................~ ............. ~ ............ D 5.00 ...................... ~ ................. x 5 50 ................................ L ........J ...................... tooo ) fi. 50 ............... t ................ ~ I TVD 6BO0~ / I T,D 7300.' I I ge . i2S' -1- 7.00 ~ .... ~--F ........ J ........ ~ .......... T ~ ............................... ' I · , I ' t B.O0 ~ ...................... : .............. : ................. -o.so o o.~o t.oo ~.so ~.oo ~.~o 3.00 3.so a.oo 4.~o 5.00 5.50 C_ Note.'; ' All valtl~.:, in fe~t. Depths shown ,3r~ T:/D. C!osurc: 2t25 ft ~t ~ 25 d~]~l 0 ~in E Bottom ho!e: TVD 6900 TMD 72.57 Magnetic de~l~nntion: 24 de~ 20 m~n g HOHiZONTAL VIEW 'UNION OIL COMPANY OF CALIFORNIA RADIU% OF GURVATURE WELL PROPOSAL SCALE ' 1 inch : 500 feet DRAWN · 6-27-85 PROPOSED WELL KBU 1 2X-8 DUAL 3 1/2",9.2-~,N-80 BUTTRESS "XA' SLEEVE TOP UPPER BELUGA +5130' MD, + 4730' VD. 20':,94-,~,K-55 DRIVEN TO -,.100' 13 3/8";68,~;K-55 BUTTRESS _+. 2000' MD DUAL PACKER 'XA' SLEEVE BLAST JOINTS TOP MIDDLE/LOWER BELUGA +- 58 70' MD. zl: 5380' VD. PLUG AT TD. "XA" SLEEVE SINGLE PACKER Ala~,a Ol~ &. Gas Cor~ .(.:(~..~;m~f~r,,, A~chora~e 9 5/8",47+,N-80 BUTTRESS ~7300' MD. -+6900' VD. CASING AND TUBING DESIGN WELL I?-X°8 FIELD ~£HA\ GAS CASING STR~NG BOROUGH k(' ~', STATE, 1. MUD WT. I ~,%- #/§% HYD GR. I d),~ psi/ft. MUD WT. II /~.0 f~/q. HYD. GR. II ~.$2_ psi/ft. MoS.Po ~?.90 psi. 2. INTERVAL DESCRIPTION CASING SIZE Bottom Top LENGTH Wt. Grade Thread 1. 2o ! Ioo o IoO -~r~: )c~s-' WEIGHT TENSION MINIMUM COLLAPSE COLLAPSE INTERNAL W/ 8F -top of STRENGTH PRESS. ~ RESIST. BURST HININUH ~/0 BF_~__ section TENSION bottom tension PRESSURE YIELD lbs-- lbs 1000 lbs TDF psi psi CDF psi psi B~ s,,.,,-oo ~,~.c~ /tiao /~7 ~-o~) 5"'zo ~.4- 5o ~o 4z.z CHOKE MANIFOLD SEE DRAWING HYDRAULIC VALVE GATE FLEX HOSE IF REQ. TO MUD PUMPS & CEMENT UNIT GATE ANGLED FILL UP LINE HYDRIL BLIND RAMS PIPE RAMS CHECK VALVE GATE GATE PIPE RAMS FROM MUD PUMP..c & CEMENT UNiT CONTRACTOR FURNISHED OPERA TOR FURNISHED WELL NAME: - - RIG CONTRACTOR: Rrink~.rhoff-Signal RIG: 54 STACK PRESSURE RATING: 5M CHOKE LINE SIZE & MSP; 3" 5tv1 NOTE: ALL CHANGES MUST HAVE WRITTEN APPROVAL BY THE DISTRICT DRILLING SUPERINTENDENT DEPT. APPROVAL DATE, 1 3 5/8' NOTES: 1. HYDRAULIC VALVES OPEN AUTOMATICALLY WHEN DIVERTER IS CLOSED. 2. FLEX HOSE IS TO BE USED AS NECESSARY. - ,_ RECEIVED Anchorage BOPE STACK 5M OR 1OM ALL OPERATIONS DnAWN BHE CKD. CCI% o APP'D. SCALE ,N 0 N E DATE 612618~ ii i 20" CONDUCTOR DIVERTER (LAND) ~¥ I 20", 2OOOpsi ~ ..~ ~:_ ' 10" HYDRAULIC VALVE ANNULAR ._.._.__.._.__~ ~-~ .... ~: [~;~¢ VALVE* 10" ~ ~ ~i' 10" 20", 2000p,i~~' ~ ~10" LOW TARGETED TURN VALVE ~ 20~ CO~HCTO~ AUTOMATICALLY WHEN ANNULAR '"'~ PREVENTER IS CLOSED. .~,n,:/, ~,~ - 0o/~,/~/~ BUTTERFLY VALVES TIED ..... .~3 TOGETHER SO THAT ONE IS OPEN AND ONE IS CLOSED. ' 3. TWO DIFFERENT DIRECTIONS DEPT. APPROVAL OF DIVERSION. NOTE: ALL CHANGES ~UST HAVEWRITTEN APPROVAL BY THE DISTRICT DRILLING SUPERINTENDENT. ~ O~TE - ! - CONDUCTOR DIVERTER (LAND) , ~ UNION OIL COMPANY OF CAL~'FORNIA , ~ ~-- ANCHORAGE, ALASKA 5MEETS ;SWEET , , , , FROM CHOKE LINE 3 , 5000+ VALVE (SIDE VIEW) 3 , 5000'~' VALVE / _J F- -1 WALl. OF__CHOKE HOUSE OUTSIDE OF CHOKE HOUSE L_ ~ /3", 5000psi TEE j3", 5000~' VALVE TO RESERVE PIT ' ~ o,,~. Co~~ ~~seio~O00 + VALVE TO RESERVE PIT RIG = 54 BRINKERHOFF UNION OIL ,-~OMPANY OF CALi~CPNIA p M.E.G. NONE 10/15/85 NOTE' ALL TURNS WILL BE TARGETED 90 DEGREES CHECK LIST FOR NEW WELL PERMITS ITEM APPROVE DATE , , (1) Fee (2) Loc (Z thru 8) (3) Admin (9' thru 12) (10 and 12) (4) Cas g~. ~.~, /~_/ (13 thru '2'1) (5) ~OPE~ /~_/~-.~,~- (22 thru 26) Company Lease & Well No. YES NO - _ 1. Is the permit fee attached ............................ .............y/M:~-~w -~. , , 2. Is well to be located in a defined pool ......................... 3. Is well located proper distance from property line .... 4. Is well located proper distance from other wells ...... 5. Is sufficient undedicated acreage available in this poo 6. Is well to be deviated and is wellbore plat included .. . 7. Is operator the only affected party ................... 8. Can permit be approved before ten-day wait ............ ' 9, 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. Does operator have a bond in force ........................ .......... Is a conservation order needed ...................................... Is administrative approval needed ................................... Is the lease number appropriate ..................................... Is conductor string provided ...................................... Is enough cement used to circulate on conductor and surface ....... Will cement tie in surface and intermediate or production strings . Will cement cover all known productive horizons ................... Will surface casing protect fresh water zones ..................... Will all casing give adequate safety in collapse, tension and burst Is this well to be kicked off from an existing wellbore ........... Is old wellbore abandonment procedure included on 10-403 .......... Is adequate wellbore separation proposed .......................... Is a diverter system required ............................... Are necessary diagrams of diverter and BOP equipment attached Does BOPE have sufficient pressure rating - Test to ~OgP~ Does the choke manifold comply w/API RP-53 (Feb.78) .......... Is the presence of H2S gas probable ......................... Additional requirements ............................................. ? Additional Rem, arks: ~ ~2,¢'~'.. ~' '.2~ / / 0 H o Geology: Eng~Re~rin~: ....... rev: 03/13/85 6.011 INITIAL GEO. UNIT ON/OFF ,, POOL CLASS STATUS AREA NO. SHORE