Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAbout2019-02-20_319-077STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION APPLICATION FOR SUNDRY APPROVALS 20 AAC 25.280 1. Type of Request: Abandon 0 Plug Perforations ❑ Fracture Stimulate L'l Repair Well LJ Operations shutdown LJ Suspend ❑ Perforate ❑ Other Stimulate ❑ Pull Tubing ❑ Change Approved Program ❑ Plug for Redrill ❑ Perforate New Pool ❑ Re-enter Susp Well ❑ Alter Casing ❑ Other: Testing 0 2. Operator Name: 4. Current Well Class: 5. Permit to Drill Number: ConocoPhilli s Alaska Inc. Exploratory El Development ❑ 218-146 3. Address: 6. API Number: Stratigraphic El Service ❑ P. O. Box 100360, Anchorage, Alaska 99510 50-103-20785-00-00 7, If perforating: 8. Well Name and Number: What Regulation or Conservation Order governs well spacing in this poc NIA Will planned perforations require a spacing exception? Yes ❑ No Tinmiaq 15 9. Property Designation (Lease Number): 10. Field/Pool(s): AA08181 a Exploratory 11. PRESENT WELL CONDITION SUMMARY Total Depth MD (ft): Total Depth TVD (ft) Effective Depth MD: Effective Depth TVD MPSP (psi): Plugs (MD): IJunk (MD): Casing Length Size MD TVD Burst Collapse Structural Conductor Surface Intermediate Production Liner Perforation Depth MD (ft): Perforation Depth TVD (ft): Tubing Size: Tubing Grade: Tubing MD {ft}: Packers and SSSV Type: Packers and SSSV MD (ft) and TVD (ft): 12. Attachments: Proposal SummarU.] Wellbore schematic❑ 13. Well Class after proposed work: Detailed Operations Program ❑ BOP Sketch ❑ Exploratory [Z Stratigraphic ❑ Development ❑ Service ❑ 14. Estimated Date for 15. Well Status after proposed work: Commencing Operations: 3/15/2019 OIL ❑ ❑ WINJ ❑ WDSPL Suspended ❑� 16. Verbal Approval: Date: GAS ❑ WAG ❑ GSTOR ❑ SPLUG ❑ Commission Representative: GINJ ❑ Op Shutdown ❑ Abandoned ❑ 17. 1 hereby certify that the foregoing is true and the procedure approved herein will not be deviated from without prior written approval. Authorized Name: Sandeep Pedam Contact Name: Sandeep Pedam Authorized Title: Staff Completions Engineer Contact Email: Sandeep.Pedam@conocophillips.com Contact Phone: (907) 263-4724 Authorized Signatu Dale: �fi� r COMMISSION USE ONLY Conditions of approval: Notify Commission so that a representative may witness Sundry Number: 0 1 Plug Integrity ❑ BOP Test ❑ Mechanical Integrity Test❑ Location Clearance ❑ Other: Post Initial Injection MIT Req't Yes ❑ No ❑ Spacing Exception Required? Yes ❑ No ❑ Subsequent Form Required: APPROVED BY Approved by: COMMISSIONER THE COMMISSION Date: Submit Form and Form 1p ap3 Revised 4/2017 Approved app nation is valid for 12 months from the date of approval. Attachments in Duoiicata From, Sandeep Pedam ConocoPhillips Alaska 700 G St, Anchorage, AK, 99502 To, Guy Schwartz Alaska Oil & Gas Conservation Commission 333 W 7t" Ave #100, Anchorage, AK 99501 Pursuant to regulation 20 AAC 25.283, ConocoPhillips would like to submit a request to hydraulically stimulate Tinmiaq 15. Stimulation will occur in accordance with regulations of the state and ConocoPhillips will ensure all Health, Safety, and Environmental regulations are adhered tn. Tinmiaq 15 is an exploration well, and ConocoPhillips would like to inform AOGCC that information contained herein is deemed confidential. Therefore, we request all the information in the sundry to be redacted. Regards, Sandeep Pedam Staff Completion Engineer TO THE ALASKA OIL AND GAS CONSERVATION COMMISSION Before the Commissioners of the } Alaska Oil and Gas Conservation ) Commission in the Matter of the } Request of ConocoPhiilips Alaska, Inc. for ) Hydraulic fracturing for the Tipmiaq 15 Well } under the Provisions ) of 20 AAC 25.280 } STATE OF ALASKA N THIRD JUDICIAL DISTRICT AFFIDAVIT OF Garrett B. Haag H Garrett B. Haag, being first duly sworn, upon oath, deposes and states as follows: My name is Garrett B. Haag. I am over 19 years old and have personal knowledge of the matters set forth herein. 2. 1 am Staff Landman for the well operator, ConocoPhiilips Alaska, Inc. CCPAI") 3. Pursuant to 20 AAC 25.283 (1) CPAI prepared the attached Notice of Operations ('Notice"). 4. On February 5, 2019, CPAI sent a copy of the Notice by certified mail to the last known address of all other owners, landowners, surface owners, and operators of record within a one-half mile radius of the current proposed well trajectory. Subscribed and sworn to this 51h day of February 2019. _ A -A e, Lk—� STATE OF ALASKA Garrett B. Haag } §§ THIRD JUDICIAL DISTRICT This instrument was acknowledged before me this 5t' day of February 2019, by Garrett B. Haag. r Notary u lic, to s of Alaska My Commission Expires: SLATE Of ALASKA NOTARY PUBLIC REBECCA SWENSEN CanmEssion Ex irss Au My . 27, 2Q2U. h_.Oncllcoph r s 1 ills Alaska February 4, 2019 To: Operator and Owners (shown on Exhibit 2) P. O. BOX 100360 ANCHORAGE, ALASKA 99510-0360 Garrett B. Haag, Staff Landman Land Department, ATO 1480 Phone (907) 265-6297 Fax (907) 2634966 Garrett.B.HaagQa eop.com VIA CERTIFIED MAIL Re: Notice of Operations pursuant to 20 AAC 25.283 (1) for Tirimiaq 15 BLM Serial No. AA-081810 Bear Tooth Unit, Alaska CPAI Contract ATo. 206223 CPAI Lease No. 932545 Dear Operator and Owners: ConocoPhilIips Alaska, Inc. ("CPAI") as Operator and on behalf of the Bear Tooth Unit, hereby notifies you that it intends to submit an Application for Sundry Approvals for stimulation by hydraulic fracturing pursuant to the provisions of 20 AAC 25280 ("Application") for the TiBmiaq 15 Well (the "Well"). The Application will be filed with the Alaska. Oil and Gas Conservation Commission on or about February 15, 2019. This Notice is being provided pursuant to subsection of 20 AAC 25.283. The Well is planned to be drilled as a straight hole on lease AA-081810 as depicted on Exhibit I with planned surface and bottomhole locations as follows: Location FNL FEL Surface 2,620' 10, Bottomhole 2,620' 10, Township + Range I Section Meridian ION I I W 111 9 Unliat ION 1 1 W 9 I Umiat Exhibit 1 shows the location of the Well and the lands that are within a one-half mile radius of the current proposed trajectory -of the Well, including the reservoir section ("Notification Area"). Exhibit,2 is a list of the names and addresses of all owners, landowners and operators of record of all properties within the Notification Area. Upon your request, CPAI will provide a complete copy of the Application. If you require any additional information, please contact the undersigned. Sincerely, �tT 4,— Garrett B. Haag Staff Landman Attachments: Exhibits I & 2 Notice of Operatiam,ptunumt +0 20 AAC 25:283 (1) fir 1'IUM' faq 15 l;0.brm'y 4, 2019 Exhibit l B Head Toolh 32 w A dA AA881740 A N 17 16 AA081809 28 21 ' ON.RI AA091823 11 2 i6 14 Drilled Well * Explorakn Well — — If2 mge.Buf[er ® Unit E3ourt[iVas CPAI Lease AA081807 � acGnRls 22 COnCKXftiIII Page 1 n__f 1 Notice of Operations pursuant to 20 AAC 25.283 (1) for Tigmiaq 15 February 4, 2019 Exhibit 2 List of the names and addresses of all owners, landowners and operators of aII properties within the Notification Area. Operator and Record Title Owner of Oil and Gas Leases: ConocoPhillips Alaska, Inc. 700 G Street, Suite ATO 2176 (Zip 99501) P.O. Box 100360 Anchorage, AK 99510-0360 Attention: Lorna Richmond, Alaska Exploration Manager Landowner: United States Department of Interior Bureau of Land Management Alaska State Office 222 West 7th Avenue, #13 Anchorage, Alaska 99513 Attn: Branch Chief, Energy and Minerals Surface Owner: United States Department of Interior Bureau of Land Management Alaska State Office 222 West 7th Avenue, #13 Anchorage, Alaska 99513 Attn: Branch Chief, Energy and Minerals Via Certified Mail No. 7016 1370 0000 0849 2411 Via Certified Mail No. 7016 1370 0000 0849 2411 Page I of 1 Section 1- Affidavit 10 AAC 25.283 (a)(1) Exhibit 1 is an affidavit stating that the owners, landowners, surface owners and operators within one- half mile radius of the current or proposed wellbore trajectory have been provided notice of operations in compliance with 20 AAC 25.283(a)(1) Affidavit Section 2 -- Plat 20 AAC 2 5.2 83 (a) (2) Plat 1: Wells within 0.5 mile Table 1: Wells within 0.5 mile Section 3 -Freshwater Aquifers 20 AAC 25.283(a) (3) There are no freshwater aquifers or underground sources of drinking water within one-half mile radius of the current or proposed wellbore trajectory. Section 4 - Plan for Baseline Water Sampling for Water Wells 20 AAC 25.283 (a) (4) There are no water wells located within one-half mile of the current or proposed wellbore trajectory and fracturing interval. A water well sampling plan is not applicable. Section 5 Detailed Cementing and casing information 20 AAC 25.283(a)(5) All casing is cemented in accordance with 20 AAC 25.030(b) and tested in accordance with 20 AAC 25.030 (e) when completed. This information is confidential and is therefore redacted Section 6 - Assessment of each casing and cementing operation to be performed to construct or repair the well 20 AAC 25.283(a)(6) This information is confidential and is therefore redacted Section 7 -- Pressure test information and plans to pressure test casing and tubings installed in the well 20 AAC 2 5.2 83 (a) (7) 20 AA!C 25,2, Hydraulic fracturing This information is confidential and is therefore redacted Section 8 - Pressure ratings and schematics for the Wellbore, Wellhead, BOPE and Treating head 20 AAC 25.283(a)(8) 20 AC 25.283. Hydraulic frac in (a) Before hydraulic fracturing, the operator must submit an Application for Sundry Approvals (Form 10- 403) under 20 AAC 25.280. Unless modified or altered by pool rules established under 2.0 AAC 25.520, the application must include (8) accurate pressure ratings and schematics for the wellbore, wellhead, ROPE, and treating head; This information is confidential and is therefore redacted Stimulation Surface Rig -Up A 7 a .5 ru I 5+ i C7 FraC P", sj • Min. press. Rating on all surface treating lines 10,000 psi • Main treating line PRV set to 95% of max. treating pressure • IA parallel PRV set to 3600 psi • Frac pump trip pressure setting staggered and set below main treating line PRV • Tree saver used on all fracs rated for 15,000 psi Purim Trudt ProcPcrt�p frod-ury Tree Saver With Wellhead r, OILS TAT S E Enargy &Ncss (Canada) Inc, QUOTEO; Maximum Allowable Pumping Rates DATE: PROPOSAL: CBG 112" E IQ Haric 1 .750 10 Ohnin 2.750 2.360 6 m1min 4 n0min 2 3-8 231811 1,000 1.000 2 r0min 3 1/16 & 41116 with tapared mandral 14 ihik-f;of Mandrel 50 4.000 3.010 4.790 24 Wimin sa LON nWA9 OM Ott mmato MIR 94 W-�ref Pressure rating: 15,000psi I t- " 4.*1'0AFx-' ^qtW'Vft nmtwTyl-% www.oaescanadaxam cf-cav:j? JAororom 74 T1 3. 'thl Wellhead 4tN r"IR'llm"04 — r-mo Nimim-1. —10R. FORP 0 LLCFMF�' S:W*4 AI,-.'OAQ PA %b if -Q� w 'Alm vo GRINTER-ATION 5 WELLHEAD int N m I flip, .2o.qw ;7:P Section 9 - Data for Fracturing zone and confining zones 20 AAC 25.283(a)(9) This information is confidential and is therefore redacted Section 10 - Location, Orientation and a Report on Mechanical Condition of Each Well that may Transect Confining Zone 20 AAC 25.283(a)(10) There are no wells within on -half mile radius of the proposed wellbore trajectory Section 11- Location of, Orientation of and Geological Data for Faults and Fractures that may Transect the Confining Zones 20 AAC 25.283(a)(11) This information is confidential and is therefore redacted Section 12 -- Proposed Hydraulic Fracturing Program 20 AAC 25.283(a)(12) This information is confidential and is therefore redacted Section 13 - Post -Fracture Wellbore Cleanup and Fluid Recovery Plan 20 AAC 25.283 (a) (13) This information is confidential and is therefore redacted II r S� S s S m m m m m m m = cm 0 3 m i 6 c n m m PO m aq a m01 ni E• m ®m m �E _ - 7 Y ry e�U u w Si (9ITi O m LL s` `s m m A. n � rcm ¢ 0 U z m [7 e a < 3F i V a a Z 3 CL m a a a E a A a C p p 2 � J w ~ o�� °F Ir f •. al� .A y � a @ m 'v a ° v � L •E �m d � $ a �d �y a m € C oe m m N •) d C b ° d d _ 6 Z' Q 'C d O m n �n 4 0 � d LL m B s �[do C •� C d ° n� s€ w� a oa a �g c � m a= Or �W �F �d 7 E 0 L�Bo m3a 9 BUJ NfnN � mr: ace � o LL L pa m� a •E ni UL m �rl . a a E a� 0 mN m E n - �.g1 80;