Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAbout185-128Image Project Well History File Cover Page
XHVZE
This page identifies those items that were not scanned during the initial production scanning.
They are available in the original file, may be scanned during the rescan activity or are viewable
by direct inspection of the file.
/~?J_¢~? Well History File Identifier
RESCAN DIGITAL DATA
[] Color items: [] Diskettes, No.
[3 Grayscale items: [] Other, No/Type
[] Poor Quality Originals:
[] Other:
To,^ PAGES; JJ .O,ES=
ORGANIZED BY: BEVERLY BREN VINCENT SHERYL MARIA LOWELL
DATE:
OVERSIZED (Scannable)
[] Maps:
[] Other items scannable by
large scanner
OVERSIZED (Non-Scannable)
[] Logs of various kinds
[] Other
IS~
Project Proofing
[] Staff Proof
By: Date:
PROOFED BY: BEVERLY BREN VINCENT SHERYL MARIA LOWELL DATE:
/s/
PAGES: // (at the time of scanning)
SCANNED BY: BEVERLY ~ VINCENT SHERYL MARIA LOWELL
DATE:
RESCANNED BY: BEVERLY BREN VINCENT SHERYL MARIA LOWELL
DATE:
Is~
General Notes or Comments about this file:
PAGES: // ~
Quality Checked (done)
Rev1 NOTScanned.wpd
Memorandum
To:
Re~
State of Alaska
Cancelled or Expired Permit Action
EXAMPLE: Point Mclntyre P2-36AXX AP1 # 029-22801-95
Oil and Gas Conservation Commission
This memo will remain at the front of the subject well file.
Our adopted con{/entions for assigning APl numbers, permit numbers and well names did not
specifically address expired or cancelled permits. This omission has caused some inconsistencies in
the treatment of these kinds of applications for permit to ddll. Operators have asked us to adopt
formal procedures for this class of permit application in order to prevent future database disparities.
If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain
unchanged. The APl number and in some instances the well name reflect the number of preexisting
reddlls and or multilaterais in a well. In order to prevent confusing a cancelled or expired permit with
an active well or multilateral these case sensitive well identifiers will be changed for expired and
cancelled applications for permits to ddll.
The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95.
The well name for a cancelled or expired permit is modified with an appended xx.
These procedures are an addendum to the APl numbering methods described in AOGCC staff
memorandum "Multi-lateral (weilbore segment) Ddiling Permit Procedures, revised December 29,
1995.
AOGCC database has been changed to reflect these changes to this permit.
e McMains - {
Statistical Technician
Telecopy No.
(907) 276-7542
December 8, 1988
David J Oryall
President
Alaskan Crude Corporation
P O Box 11-1187 ''
Anchorage, AK 99511
Re: .~Katella Wells KS-1 thr°ugh KS-10
·
Dear,Mr Oryall: .......
A sundry notice, approved 3/7/88, was submitted for welI KS-1 to
pull and re-run tubing with bottom hole p,,mp, and to evaluate the
well during 1988. If this work has been done, please report the . .
results on a Report of Sundry Well Operations, form 10-404.
.
_
This is a reminder that the 10-401 Drilling Permits for Katella
wells KS-2 through KS-10 expired in July of 1987 [per 20 AAC ~: ~-
25.005(h)]. If you wish to drill these wells, it will be
necessary to apply for new permits. :
If you have questions, please contact me or Lonnie Smith.
s t _n,c r y: f
.
C V Chatterton
Chairman
Jo/A.BEW.126
Telecopy No.
(907) 276-7542
November 21, 1988
David J Oryall
Vice President
Alaskan Crude Corporation
550 West 7th Ave, Suite 1600
Anchorage, AK 99501
Re~ Katella Wells KS-1 through KS-10
Dear Mr Oryall,
A sundry notice, approved 3/7/88, was submitted for well KS-1 to
pull and re-run tubing with bottom hole pump, and to evaluate the
well during 1988. If this work has been done, please report the
results on a Report of Sundry Well Operations, form 10-404.
This in a reminder that the 10-401 Drilling Permits for Katella
wells KS-2 through KS-10 expired in July of 1987 [per 20 AAC
25.005(h)]. If you wish to drill these wells, it will be
necessary to apply for new permits.
If you have questions, please contact me or Lonnie Smith.
C V Chatterton
Chairman
!
Jo/A.BEW.126
July 1, 1985
Mr. David J. Oryal!
Vice President
Alaskan Crude Corporation
550 W. Seventh Avenue, Suite 1600
Anchorage, Alaska 99501
Re: Katalla KS-5
Alaska Crude Corporation
Permit ~o. 85-128
Sur. LOC. 2030'~L, 2040'SI~ Sec. 36, T19S, R5E, CRM.
Btmhole Loc. S A M E
Dear Mr. Oryal!:
Enclosed is the approved application for permit to drill the
above referenced well.
If coring is conducted, a brief description of each core and a
one cubic inch size chip from each foot of recovered core is
required. Samples of drill cuttings and a mud log are not
required. An inclination survey is required as per 20 AAC
25.050(a)(2). If available, a tape containing the digitized log
information shall be submitted on all logs for copying except
experimental logs, velocity surveys amd dipmeter surveys.
Many rivers in Alaska and their drainage systems have been
classified as important for the spawning or migratiOn of
anadromous fish. Operations in these areas are subject to
AS 16.05.870 and the regulations promulgated thereunder (Title 5,
Alaska Administrative Code). Prior to commencing operations you
may be contacted by the Habitat Coordinator's Office, Department
of Fish and Game.
Pollution of any waters of the State is prohibited by AS 46,
Chapter 3, Article 7 and the regulations promulgated thereunder
(Title 18, Alaska Administrative Code, Chapter 70) and by the
Federal Water Pollution Control Act, as amended. Prior to
Mr. David J. OryalJ_
Kataila KS-5
-2- July t, 1985
commencing operations you may be contacted by a representative of
the Department of Environmental Conservation.
To aid us in scheduling field work, please notify this office 24
hours prior to commencing installation of the blowout prevention
equipment so that a representative of the Commission may be
present to witness testing of the equipment before the surface
casing shoe is drilled, k~ere a diverter system is required,
please also notify this office 24 hours prior to co~encing
equipment installation so that the Commission may witness testing
before drilling below the shoe of the conductor pipe.
In the event of suspension or abandop~ent, please give this
office adequate advance notification so that we may have a
witness present.
Ve?~y-.,t rul y y~o~rs,
· /' ~-., l/' . / .'
,., ,,.:- ;:- /: ,./ /'
z- : .? /.:"/--Z. // Z~
jr, ; . ! ,, . . ..m. / /~.. z.
......... . ........... / , / .- ~
C. V. ChattertOn
Chairman of
Alaska Oil and Gas Conservation Commission
be
Enclosure
CC:
Department of Fish & Game, Habitat Section w/o enct.
Department of Environmental Conservation w/o encl.
Mr. Bill H. Lamoreaux
06-12-85.1M6
Alaskan Crude Corporation
Hunt Building
550 West 7th Avenue, Suite 1600
Anchorage, Alaska 99501
(907) 388-6863
June 10, 1985
Alaska Oil and Gas Conservation
Commission
3001 Porcupine Drive
Anchorage, Alaska 99501
RE: Application for Permits to Drill
Alaskan Crude Corporation
Katalla-Stevens No. 1 through No. 10
Gentlemen:
Please find enclosed three copies each of our Application for Permit
to Drill for the Katalla-Stevens No. 1 through No. 10 exploratory
wells on Oil Claim No. 1 at Katalla. Included are the following docu-
ments:
I ·
2.
3.
4.
AOGCC Form 10-401
AOGCC Conservation Order-No. 179
Location Plat
Filing Fee of $100 per well
Thank you for your consideration of these applications. If you re-
quire additional information, pTease contact Mr. Kelly Goff at Alaskan
Crude.
Sincerely,
ALASKAN CRUDE CORPORATION
David J. Oryall
Vice President/Exploration
DJO/ra
Enclosures
RECEIVED
JUN 1 21 B5
Alaska Oil & Gas Cons. Commission
Anchorage
STATE OF ALASKA -
ALASKA OIL AND GAS CONSERVATION COMMISSION
PERMIT TO DRILL
20 AAC 25.00,5
la. Type of work.
DRILL
REDRILL
DEEPEN
lb. Type of well
E XPLORATORY'2~
DEVELOPMENT OIL []
DEVELOPMENT GAS I'-I
SERVICE [] STRATIGRAPHIC L_~
SINGLE ZONE [~]
MULTIPLE ZONE []
2. Name of operator
ALASKAN CRUDE CORPORATION
3. Address
550 W 7th Ave., Suite 1600 Anchor_a_g~_,_Alaska
4. Location1 '~-! ~ell 'at s~rlace -"
2030' WEL, 2040 SNL,
A! top of proposed producing interval
Same
At total depth
Same
' 5. Elevatio'-i~ feet {indicate K'B. DF etc.)
~ 85 f KB
12. Bond information {see 20 AAC 25.025!
Sec. 36, T19S, R5E, CRM
Oil Claim No. 1
CD #0100000452
99501
g. Unit or lease name
Katalla
10. Well number
KS-5
11. Field and po~i
Katalla Field
Katalla Pool
Type Blanket Su,e,v and/or numberRainier Bank A] aska
13.'O,stance and direction from nearest town 14. Distance ,o nearest property or lease1_.?0-~ 7
Cordova NW ~ 60 miles Property line 'to Nort~efi-
16. Propos~dd~pth (MD & TVD} 17. Number of acres in lease
1,800 fe~, 151· 17
19. If deviated (see 20 AAC 25.050)
KICK OF F POINT feet. MAXIMUM HOLE ANGLE
21
20. Anticipated pressures
{see 20 AAC 25.035 (c) (2)
Amount ~ 2 I") (').; 0 -~0; 0 0
15. Distance i'D nearest drilling or completed
well . n/a feet
18. Approxima'te spud date
July 22, 1985
30'0' psig~__ · _Surface
_ R 4 2_.___psig@~ft. TD {TVD)
Proposed Casing, Liner and Cementing Program
SIZE ....... CASING AND LINCh SETTING DEPTH hUANTITY bF CEMENT
, ,,
Hole '-~asi;~-- Weight Grade ~ou~li%%:~englh MD TOP TVD '~DBOTTOMTVD '' (incJudestagedatal
~ ~"-57~- ~6---~-'K55 "'8rd 80,--surfac~ 8.0,. I "80, to surface
"8 '~'/47 20#'. K5~ "8rd 350'.. surfac~''. 350' .1~50' ~' to surface '
· ... , 310 1800 I 1800 liner will not b~
:6 ¼ 4% 11 6# K55 8rd 1490' 310 ~ .....
i I cemented ,
..- ..... , .... , ......
............................... ~ _ . ....
22. Describe p,oposed program:.
The program will meet the conditions specified in conservation order
·
No. 179 dated April 28, 1982. AOGCC will be notified sufficiently in
advance to witness pressure tests of BOPE. Casing will be cemented
using Class G oilfield cement. 4%" liner will be both blank and
slotted and will not be cemented.
-':~§'.'i h-e;~--~-c-~rt' that the ~-~'(~' g'is * and corre t
..
The space below for Comae{ion use ~
the best of my knowledge~'-,c,,~ ?0;';::?.
TITLE Vice President DATE
.6/11/85
~'~r~) les required
[]YES ~'NO
'i58 .........
Fo,m 10401
Rev. 7- !-80
CONDITIONS OF APPROVAL
Mud log required I Directional Survey required ! APl number
_~¥E..?_ ...._~,NO I E]YES ~i, io 15°- 069-20006
Approval d
r°vaj~u~Je7/.,O 1/~5 I SEE COVER LETTER FOR OTHER REQUIREMENTS
'
/~ : .COMMISSIONER DATE July 1, 1985
Submit in triplicate
B
I10
26
· ' 'A-"4'60
25
.%90
·
56
4~$
425
4.82~
MS 599
t 5 I.l-~TO
599
1.533
i_ , ,
i ·
L i ,1
L ol EO' l O~2. ~. =-° "^'
Lon~ I.~.~'~5'41.254"'14/
~'/,.R NING,
THIS PLAT I$ THE BUREfiU'S RECORD OF 'TITLE AND SHOULD BE USED
ONLY AS A GRAPHIC DISPLAY OF TOWNSHIP SURVEY DATA. RECORDS
HEREON DO NOT REFLECT TITLE CHANGES WHICH MAY HAVE BEEN
EFFECTED BY LATERAL MOVEMENTS OF RIVERS OR OTHER BODIES
OF WATER REFEr, 'I'0 THE C/.,DASTRAL SURVEY FOR OFFICIAL SURVEY
INF ORMr. T ION.
CURRENT
TC ;FI~W
i
.>
./
RECEIVED
.,
RECEIVED
JUN 17
CHECK LIST FOR NM ~L P~ITS Company
IT~ APPROVE DATE ~ YES
(1) Fee /~.~ ~~Jf ~i. Is the permit fee attached .......................................... /~
thru 8) Is well located proper distance from property line .. 22 .
Is well located proper distance from other wells ...... ' .....
Lease & Well No.
NO REMAP~S
4.
5.
&.
(3) --~.'12--~---~ 10.
(ii} arid 12) 12.
(4) Casg. ~~. ~-~-~' 13.
('13 th~u 21) 14.
t5~
!6.
[8.
20~
2t.
(22 thru 26)
23.
25.
26.
Is sufficient Undedicated acreage available in this pool ............
Is well to be deviated and is wellbore plat included .............
Is operator the only affected party~. .................
Can permit be approved before ten-day wait ..... - .....................
Does~operator have~:a'bond in force .... - ............. ; ................
Is m conservation order-needed::..~...-..;..-..- .........................
Is administrative-approva~l needed ...................................
Is-the'lease number'-appropriate. ....................................
ts:conductor string~provided .... - ................................
Is anough cement used to circulate on conduct~ and ~u~face . ..~
Will:oeement tie in sur-face andcintermediate or production strings ...
~ill ~ement 'cover-all known productive horizons ................. . ....
Will surface casing protect fresh water zones .......................
Will-all casing give adequate safety in collapse, tension and burst..
Is this Well-to-be kicked:off-from an existing wellbore .............
'Is 01d~--wellbOre abandonment procedure included on 10-403 .... ~ .......
Is~ adequate w~libore separation proPosed ............................
Ista divertersystem required .... ; ..................................
Are~eeessary. diagrams of diverter and BOP equipment attached .......
Does BOPE'~ave-~sufficient pressure rating -'Test to ~'OO psig ..~
Does-the-choke manifold-complyw/API RP-53 (Feb.78) ..................
Is the presence of H2S gas probable .................................
Additionatsrequirements ................. ;.~, ............ -..~ .........
A~di.tional~ Remarks: ¥~--i~ ~,~,~W~.'q-~- ~ ~, L.~-.
Geology: Engineering
HWK LCS BEW~.~
rev: 03/13/85
6.011
-_ INITIAL GEO. UNIT ON/OFF
POOL CLASS STATUS AREA NO. SHORE