Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAbout218-032MEMORANDUM State of Alaska
Alaska Oil and Gas Conservation Commission
DATE:Friday, October 3, 2025
SUBJECT:Mechanical Integrity Tests
TO:
FROM:Josh Hunt
P.I. Supervisor
Petroleum Inspector
NON-CONFIDENTIAL
ConocoPhillips Alaska, Inc.
1H-117
KUPARUK RIV UNIT 1H-117
Jim Regg
InspectorSrc:
Reviewed By:
P.I. Suprv
Comm ________
JBR 10/03/2025
1H-117
50-029-23602-00-00
218-032-0
W
SPT
3669
2180320 1500
1024 1024 1024 1026
20 50 50 50
4YRTST P
Josh Hunt
8/22/2025
30 MinPretestInitial15 Min
Well Name
Type Test
Notes:
Interval P/F
Well
Permit Number:
Type Inj TVD
PTD Test psi
API Well Number Inspector Name:KUPARUK RIV UNIT 1H-117
Inspection Date:
Tubing
OA
Packer Depth
330 2020 1920 1905IA
45 Min 60 Min
Rel Insp Num:
Insp Num:mitJDH250822124837
BBL Pumped:1.1 BBL Returned:0.9
Friday, October 3, 2025 Page 1 of 1
TT RR AA NN SS MM II TT TT AA LL
FROM::Sandra D. Lemke, ATO-704 TO:: Meredith Guhl
ConocoPhillips Alaska, Inc. AOGCC
P.O. Box 100360 330 W. 7
th Ave., Suite 100
Anchorage AK 99510-0360 Anchorage, Alaska 99501
RE: Schlumberger Wireline Backlog – Kuparuk River Unit
DATE: 12/19/2023
Transmitted:
North Slope, Kuparuk River Unit
Via hard Drive data drop
1H-111 50-029-23581-00
217133_1H-111_IPROFWFL_03JUL2023
1H-114 50-029-23584-00
217136_1H-114_IPROF_17Oct23
1H-115 50-029-23605-00
218053_1H-115_IPROF RSTWFL_09May2022
1H-116 50-029-23594-00
218012_1H-116_IPROFWFL_05Jul2023
1H-117 50-029-23602-00
218032_1H-117_PPROF-WFL_06July23
218032_1H-117_WFL_18Oct23
1H-119 50-029-23591-00
217178_1H-119_WFL_07Jul2023
1J-102 50-029-23317-00
206110_1J-102_RPPG_18Jul2023
1J-107 50-029-23366-00
207107_1J-107_PPROF_10May2022
1J-162 50-029-23360-00
207080_1J-162_LDL_03May2022
1J-170 50-029-23310-00
206062_1J-170_Temp-Pres_11Jul2023
1J-176 50-029-23364-00
207099_1J-176_LDL_11May2022
4of 12
Transmittall instructions: please promptly sign, scan, and e-mail to Sandra.D.Lemke@conocophillips.com
Receipt: Date:
Alaska/IT-Support Services GGRE |ConocoPhillips Alaska |Office: 907.265.6947; Mobile 907.440.4512
T38340
T38341
T38342
T38344
T38343
T38345
T38346
T38347
T38348
T38349
T38350
2/29/2024
1H-117 50-029-23602-00
218032_1H-117_PPROF-WFL_06July23
218032_1H-117_WFL_18Oct23
Kayla
Junke
Digitally signed
by Kayla Junke
Date: 2024.02.29
11:34:11 -09'00'
WELL NAME API #SERVICE ORDER # FIELD NAMESERVICE DESCRIPTIONDELIVERABLE DESCRIPTION DATA TYPEDATE LOGGEDCOLOR PRINTS CDsCD5-1950103207600000 CRU WLSetting RecordFINAL FIELD3-Aug-21CD5-1950103207600000 CRU WLSetting RecordFINAL FIELD11-Aug-21CD5-9650103208110000 CRU WLPERFFINAL FIELD21-Jul-21CD2-31050103208260000 CRU WLDCSTFINAL FIELD16-Sep-21CD2-31050103208260000 CRU WLUSITFINAL FIELD24-Aug-21CD2-31050103208260000 CRU WLUSITFINAL FIELD25-Aug-21CD5-3150103208280000 CRU WLPERFFINAL FIELD27-May-21CD1-01A50103202990100 CRU WLRSTFINAL FIELD12-Sep-21MT7-0650103208310000 GMTU WLCORROSIONFINAL FIELD3-Oct-21MT6-0850103207720000 GMTU WLPSRFINAL FIELD14-Sep-21MT6-0850103207720000 GMTU WLPSRFINAL FIELD22-Oct-21MT7-0650103208310000 GMTU WLMECH CUTTERFINAL FIELD2-Sep-21MT7-0650103208310000 GMTU WLUSITFINAL FIELD12-Dec-21MT7-0650103208310000 GMTU WLUSITFINAL FIELD16-Dec-21MT7--0150103208320000 GMTU WLSCMTFINAL FIELD15-Nov-21MT7-0650103208310000 GMTU WLUSITFINAL FIELD19-Feb-21Lookout 150103203590000 GMTU WLRSTFINAL FIELD29-Mar-21Lookout 150103203590000 GMTU WLRSTFINAL FIELD2-Apr-21Delivery Receipt______ďďLJĞůů_____X_______________________________________Print Name Signature DatePlease return via courier or sign/scan and email a copy to Schlumberger.A Delivery Receipt signature confirms that a package (box, envelope, etc.) has been received. The package will be handled/delivered per standard company reception procedures. The package's contents have not been verified but should be assumed to contain the above noted SLB Auditor-Originated:PTS - PRINT CENTER600 E 57th Pl - Ste AAnchorage, AK 99518Delivered to:AOGCCATTN: Natural Resources Technician333 W. 7th Ave., Suite 100Anchorage, AK 99501-3539Transmittal Date:20-Dec-21Transmittal #:________________Signature12/21/2021Wd͗ϮϭϴϬϯϮϬͲ^Ğƚ͗ϯϲϮϲϳJRBy Abby Bell at 1:43 pm, Dec 21, 2021
1H-11950029235910000 KRU WLIPROFFINAL FIELD24-Jun-211H-11750029236020000 KRU WLIPROFFINAL FIELD16-Jun-213H-31A50103202050100 KRU WLCUTTERFINAL FIELD31-Jul-213S-61150103207740000 KRU WLCUTTERFINAL FIELD11-Oct-211R-10150029214040300 KRU WLSAMPLINGFINAL FIELD30-Jun-213H-3750103208220000 KRU WLGLSFINAL FIELD29-May-213F-0450029214490000 KRU WLIPROFFINAL FIELD23-Feb-211J-10150029232860000 KRU WLPPROFFINAL FIELD2-Mar-211D-0250029204290000 KRU WLIPROFFINAL FIELD17-Feb-21MP-150029205730000 KRU WLPERFFINAL FIELD18-Feb-21MP-150029205730000 KRU WLPERFFINAL FIELD20-Feb-21MP-150029205730000 KRU WLSCMTFINAL FIELD28-Mar-211G-0250029208130000 KRU WLIPROFFINAL FIELD1-Apr-211C-19050029231360000 KRU WLIPROFFINAL FIELD30-Oct-212L-31850103206810000 KRU WLIPROFFINAL FIELD24-Jul-21
MEMORANDUM State of Alaska
Alaska Oil and Gas Conservation Commission
TO:Jim Regg DATE: Friday, August 6, 2021
`�
P.I. Supervisor gn' �) 14Z�Zf SUBJECT: Mechanical Integrity Tests
ConocoPhillips Alaska, Inc.
1H-117
FROM: Bob Noble KUPARUK RIV UNIT 1H-117
Petroleum Inspector
Sre: Inspector
Reviewed By:
P.I. Supry—
NON-CONFIDENTIAL Comm
Well Name KUPARUK RIV UNIT 1H-1 17 API Well Number 50-029-23602-00-00 Inspector Name: Bob Noble
Permit Number: 218-032-0 Inspection Date: 8/2/2021
Insp Num: mitRCN210802132103
Rel Insp Num:
Packer Depth Pretest Initial
15 Min 30 Min 45 Min 60 Min
Well_ ---
1H-117
— - - — - - ---
Type Inj W - TVD 3669 Tubing 1075, 1075
1075- 1075
pTD
zlso32o
Type Test
SPT
Test psi,
1500
IA
490
1810 -
1730
1720-
BBL Pumped:
0.7 -,
BBL Returned:
0.7
OA
80
160.
160
160
Interval
4YRTST p/F L P ✓
Notes:
Friday, August 6, 2021 Page 1 of 1
Originated:Delivered to:8-Jan-21
Halliburton Alaska Oil and Gas Conservation Comm.
Wireline & Perforating Attn.: Natural Resource Technician
Attn: Fanny Haroun 333 West 7th Avenue, Suite 100
6900 Arctic Blvd.Anchorage, Alaska 99501
Anchorage, Alaska 99518
Office: 907-275-2605
FRS_ANC@halliburton.com
The technical data listed below is being submitted herewith. Please address any problems or
concerns to the attention of the sender above
WELL NAME API #SERVICE ORDER #FIELD NAME JOB TYPE DATA TYPE LOGGING DATE PRINTS #DIGITAL #
1 1A-01 50-029-20590-00 n/a Kuparuk River Packer Setting Record Field- Final 6-Dec-20 0 1
2 1A-01 50-029-20590-00 n/a Kuparuk River Packer Setting Record Field- Final 7-Dec-20 0 1
3 1C-25 50-029-22941-00 906866139 Kuparuk River Packer Setting Record Field- Final 15-Dec-20 0 1
4 1H-108B 50-029-23608-02 906811421 Kuparuk River Water Flow Record Field- Final 12-Nov-20 0 1
5 1H-109 50-029-23595-00 906810847 Kuparuk River Injection Profile Field & Processed 14-Nov-20 0 1
6 1H-111 50-02923581-00 906831134 Kuparuk River Injection Profile Field & Processed 21-Nov-20 0 1
7 1H-115 50-029-23605-00 906832402 Kuparuk River Injection Profile Field & Processed 23-Nov-20 0 1
8 1H-117 50-029-23602-00 906810277 Kuparuk River Injection Profile Field & Processed 20-Nov-20 0 1
9 1J-118 50-029-23337-00 906798402 Kuparuk River Plug Setting Record Field- Final 1-Nov-20 0 1
10 1Y-19 50-029-22391-00 906849383 Kuparuk River Leak Detect Log Field- Final 7-Dec-20 0 1
PLEASE ACKNOWLEDGE RECEIPT BY SIGNING AND RETURNING A COPY OF THE TRANSMITTAL LETTER TO THE ATTENTION OF:
Fanny Haroun, Halliburton Wireline & Perforating, 6900 Arctic Blvd., Anchorage, AK 99518
FRS_ANC@halliburton.com
Date:Signed:
Transmittal Date:
Received by the 01/08/2021
01/11/2021 Abby Bell
PTD: 2180320
E-Set: 34544
Originated:
Schlumberger
PTS - PRINT CENTER
6411 A Street
Anchorage, AK 99518
(907)273-1700 main (907)273-4760fax
Delivered to:
Y AOGCC
;,, ATTN: Natural Resources Technician II
` I— Alaska Oil & Gas Conservation Commision
* 333 W. 7th Ave, Suite 100
-y Anchorage, AK 99501
218032
31482
15 -Nov -19
15Nov19JW 03
Schlumberger -Private
Originated:
Schlumberger
PTS-PRINTCENTER
6411 A Street
Anchorage, AK 99518
(907)273-1700 main (907)273-4760fax
Delivered to:
AOGCC
ATTN: Natural Resources Technician II
Alaska Oil & Gas Conservation Commision
333 W. 7th Ave, Suite 100
j& Anchorage, AK 99501
:1 32
1 ' 86
7RANSMnTAL GATE
12JuII9 -10.
TRANSMITTALa
A Transmittal Receipt signature confirms that a package (box,
(J 6(/ envelope, etc.) has been received and the contents of the
X package have been verified to match the media noted above. -
Name Signature Date specific content of the CDs and/or hardcopy prints may or may
e return via courier or sign/scan and email a copy Schlumber er and CPAL not have been verified for correctness or quality level at this
g point.
a PTSPri ntCenter(cilslb com Tom Oste rkamoCo�conocoohillins com
SLB Auditor- --I--LT
Schlumberger -Private
SERVICE ORDER
DELIVERABLE
DESCRIPTION
DATA TYPE
DATELOGGED Prints
CD's
1A-25
30-11
3K-23
50-029.22116-00
50-029-21676-00
50-029-22771.00
EBNL-00028
EBNL-00029
_UB NL -00030
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
WL
WL
WL
PPROF
LDL
LDL
FINAL FIELD
FINAL FIELD
FINAL FIELD
21 -Jun -19
22 -Jun -19
23 -Jun -19
1
1
1
2V•02
1Y-14
1H-109
1H-113
1 H-117
3H -14B
50-029-21037-00
50-029-20910-00
50.029-23595.00
50-029-23588-00
50.029-23602-00
50.103-20092.02
EBNL-00034
EBNL-00035
_ENL -00036
EBNL-00037
EBNL-00038
EOSH-00062
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
WL
WL
WL
WL
WL
WL
]PROF
(PROF
IPROF
(PROF
[PROF
LDL
FINAL FIELD
FINAL FIELD
FINAL FIELD
FINAL FIELD
FINAL FIELD
FINAL FIELD
27 -Jun -19
28 -Jun -19
29 -Jun -19
30 -Jun -19
1 -Jul -19
3 -Jul -19
1
1
1
1
1
1
2G -14A
1B -O6
18-09
3G-03
1R -22A
50.029.21161-01
50.029-20603.00
50.029-20655-00
50.103-20245.00
50-029.22206-01
EOSH-00064
EOSH-00065
EOSH-00066
EOSH-00067
EOSH-00048
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
KUPARUK RIVER
WL
WLJul•19
WL
WL
WL
LDL
PPROF
IPROF
PPROF
LDL
FINAL FIELD
FINAL FIELD
FINAL FIELD
FINAL FIELD
FINAL FIELD
5-
6 -Jul -19
7 -Jul-19
8 -Jul -19
8 -Jul -19
1
1
1
1
1
G LE 01
1
JUL 12 2pj---
14
A Transmittal Receipt signature confirms that a package (box,
(J 6(/ envelope, etc.) has been received and the contents of the
X package have been verified to match the media noted above. -
Name Signature Date specific content of the CDs and/or hardcopy prints may or may
e return via courier or sign/scan and email a copy Schlumber er and CPAL not have been verified for correctness or quality level at this
g point.
a PTSPri ntCenter(cilslb com Tom Oste rkamoCo�conocoohillins com
SLB Auditor- --I--LT
Schlumberger -Private
ConocoPhillips
Alaska
P.O. BOX 100360
ANCHORAGE, ALASKA 99510-0360
May 6; 2019
Commissioner Hollis French
Alaska Oil & Gas Commission
333 West P Avenue; Suite 100
Anchorage, AK 99501
Commissioner Hollis French:
CR iY-03a
MAY 0 S 2019
A®CCC
Enclosed please find a spreadsheet with a list of wells from the Kuparuk field (KRU). Each of
these wells was found to have a void in the conductor. These voids were filled with cement if
needed and corrosion inhibitor, engineered to prevent water from entering the annular space. As
per previous agreement with the AOGCC, this letter and spreadsheet serves as notification that
the treatments took place and meets the requirements of form 10-404, Report of Sundry
Operations. The attached spread sheet presents the well name, top of cement depth prior to filling
and volumes used on each conductor.
Please call Roger Winter or Roger Mouser at 907-659-7506, if you have any questions.
Sincerely,
Roger Winter
ConocoPhillips Well Integrity Field Supervisor
ConocoPhillips Alaska Inc.
Surface Casing by Conductor Annulus Cement, Corrosion inhibitor, Sealant Top -off
Report of Sundry Operations (10.404)
Kuparuk Field
Date 6/6/2019 11 & 1H
Well Name
API #
PTD #
Initial top of
cement
Vol. of cement
pumped
Final top of
cement
Cement top off
date
Corrosion
inhibitor
Corrosion
inhibitor/
sealant date
ft
bbls
ft
al
U-180
50029233290000
2061500
20'9"
2.80
1'5"
5/4/2019
5
5/5/2019
1H-101
50029235850000
2171380
2'10"
0.70
9"
5/4/2019
2.2
5/5/2019
1H-102
50029235800000
2170970
2'9"
0.65
8"
5/4/2019
1.7
5/5/2019
1H-103
50029235930000
2180030
2'2.5"
0.45
9"
5/4/2019
2.2
5/5/2019
11-1-104
50029236100000
2180840
2'.5"
0.40
9"
5/4/2019
2.2
5/5/2019
1H-1086
50029236080200
2180820
3'8"
0.80
10"
5/4/2019
2.5
5/5/2019
1H-109
50029235950000
2180130
2'3"
0.40
9"
5/4/2019
2.2
5/5/2019
1H-110
50029236010000
2180310
2'6.5"
0.65
8.5"
5/4/2019
2
5/5/2019
1 H-111
50029235810000
2171330
2'
0.35
9"
5/4/2019
2.2
5/5/2019
11-1-113
50029235880000
2171680
2'1"
0.40
8"
5/4/2019
1.7
5/5/2019
1H-114
50029235840000
2171360
1111"
0.25
7.5"
5/4/2019
1.8
5/5/2019
11-1-115
50029236050000
2180530
22.5"
0.35
8.5"
5/4/2019
2
5/5/2019
1H-116
50029235940000
2180120
17"
0.25
7"
5/4/2019
1.7
5/5/2019
1H-117
50029236020000
2180320
1111"
0.35
7"
5/4/2019
1.7
5/5/2019
1H-118
50029235780000
2170840
2'4"
0.50
8.5"
5/4/2019
2
5/5/2019
IH -119
50029235910000
2171780
3'
0.80
8"
5/4/2019
1.8
5/5/2019
WELL PERMIT CHECKLIST Field & Pool KUPARUK RIVER, WEST SAK OIL - 490150
Well Name: I( RARUK RIV UNIT 1H-117 Program SER Well bore seg ❑
PTD#:2180320 Company CONOCOPHILLIPS ALASKA INC. _ Initial Class/Type
SER! PEND GeoArea 890 Unit 11160 On/Off Shore On Annular Disposal ❑
Administration
17
Nonconven, gas conforms to AS31,05.0300. 1.A),(j.2.A-D) _ _ _ _ _
NA
________ _________
1
Permit fee attached_ _ .. _ _ _ .
NA
-
2
Lease number appropriate.. _ _ .. _ _ _ _ _ _ ......
Yes
_ _ _ ADL0025639, entire wellbore. . .............
3
Unique well. name and number _ _ _
Yes
KRU 1H-117
4
Well located in.a_defiined pool- - - - - - - - - - - - - _
Yes
_ _ KUPARUK RIVER,. WEST SAK OIL-- 490150,_ governed by Conservation Order No. 406C.
5
Well located proper distance, from drilling unit boundary. _ _ ..
Yes
_ _ CO 406C contains no spacing restrictions withrespect to drilling unit boundaries.. - - -
6
Well located proper distance from other wells- - - - - _
Yes
_ _ _ _ CO 406C has no interwell spacing restrictions, - - - - - - .. _ ..
7
Sufficient acreage available in drilling unit... _ _ _
Yes
8
If deviated, is wellbore plat included _ _ _ _ _ _ _ ..
Yes
9
Operator only affected party..
Yes
Wellbore.will be more than 500' from an external property line where ownership or landownership changes.
10
Operator has appropriate bond in force _ _ _
Yes
Appr Date
11
Permit can be issued without conservation order. _
Yes
PKB 3/27/2018
12
Permit can be issued without administrative approval _ _
Yes
13
Can permit be approved before 15-day wait. _ _ _ _ _ _ _ _ _ _
Yes
14
Well located within area and strata authorized by Injection Order # (put. 10# in.comments). (For.
Yes _
_ AI0.2C.
15
All wells.within 1/4 mile area of review identified (For service well only)___ _ _ _ _ _ _ _ _ _ _ _
Yes _
.... KRU 11-1-101, 1H-05._ 111-U. IH-07A, 11-1-14.
16
18
Pre-produced injector. duration of pre production less than 3 montha(For service well only) - .
Conductor stringprovided........ _ _ . . . ............
No......
Yes . _
Ben Tolman.(3/27/18) ....
_ _ _ 80' conductor set
Engineering
19
Surface casingprotects all. known USDWs .. _ _ _ _ _ _ .. _
Yes
_ _ Surface casing set to 1826' MD
20
CMT. vol adequate. to circulate on conductor & surf csg . . . ......... . . . . . . .
Yes _
_ _ 1M. excess cement
21
CMT. vol adequate to tie-in long string to surf csg_ _ _____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
No.
22
CMT. will cover all known productive horizons . . . . . . . . . ........
No
_ _ Productiveintervalwill be cemented. and perforated - -
23
Casing designs adequate for C,. T, B & permafrost . . . . . . . ............... .
Yes
24
Adequate tankage or reserve pit _
Yes _
_ Rig has steel tanks; all. waste. to approved disposal wells
25
If a re-drill, has a 10-403 for abandonment been approved .. _
NA
26
Adequate wellbore separation proposed _ _ _ _ _ _ _
Yes
And-collision analysis complete; 1 H-05 fails major risk and is P&A'd
27
if diverter required, does it meet regulations. _ _ _ _ ...
Yes
_ _ Diverter route and design meets regulations.
Appr Date
X28
Drilling fluid program schematic & equip list adequate_ _ _ _ _ _ _ _ _
Yes
Max formation pressure is 1750 psig(8.6 ppg EMW ); will drill w/. 8.8-10.0 ppg -EMW ....
VTL 4/19/2018
'29
BOPEs, do they meet regulation - - - - - - - - _ ... _ _
Yes
30
BOPE.press rating appropriate; test to (put prig in comments). _ _ _
Yes
MPSP is 1359 psig; will test BOPs to 3500_psig
31
Choke manifold complies w/API RP-53 (May 84).. .... _ _
Yes
32
Work will occur without operation shutdown- _ _ _ _ _ _ _ _ _
Yes
_ _ _ _ _ _ _ _ ...... . . . . . .... . . . . _ .... _
33
Is presence of H2S gas probable _ ___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Yes
_ H2S measures required
34
Mechanical_ condition of wells within AOR verified (For service well only) ..........
Yes
_ _ _ . 1H-07A;. WSak below SC shoe; Gas injection not approved at this time.
35
Permit can be issued w/o hydrogen sulfide measures _ _ _ _ _ _ _ _ _ _ _
No.
H26 measures required. - - - - - _ _ _ _ _
Geology
36
Data presented on potential overpressure zones ..
Yes
.....
Maximum potential. reservoir pressure is 8.6 ppg EMW; will be drilled using 8.8 to 10.0 ppg mud.
Appr Date
37
Seismic analysis of shallow gas zones_ _ _ ..... _ . . ...........
NA
PKB 3/27/2018
38
Seabed condition survey off-shore) ...
------------- --------------- �
NA _ _
_ _ _ _ _ _________
- - .. ---- ---
39
Contact name/phone for weekly-prograss reports_ [exploratory only] ......... _ _ _
NA _ _
_ _ Onshore service well to be drilled........
Geologic Engineering Public
Commissioner: Dat m' loner: atemissio y�to
4e �lzs),�