Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAbout218-032MEMORANDUM State of Alaska Alaska Oil and Gas Conservation Commission DATE:Friday, October 3, 2025 SUBJECT:Mechanical Integrity Tests TO: FROM:Josh Hunt P.I. Supervisor Petroleum Inspector NON-CONFIDENTIAL ConocoPhillips Alaska, Inc. 1H-117 KUPARUK RIV UNIT 1H-117 Jim Regg InspectorSrc: Reviewed By: P.I. Suprv Comm ________ JBR 10/03/2025 1H-117 50-029-23602-00-00 218-032-0 W SPT 3669 2180320 1500 1024 1024 1024 1026 20 50 50 50 4YRTST P Josh Hunt 8/22/2025 30 MinPretestInitial15 Min Well Name Type Test Notes: Interval P/F Well Permit Number: Type Inj TVD PTD Test psi API Well Number Inspector Name:KUPARUK RIV UNIT 1H-117 Inspection Date: Tubing OA Packer Depth 330 2020 1920 1905IA 45 Min 60 Min Rel Insp Num: Insp Num:mitJDH250822124837 BBL Pumped:1.1 BBL Returned:0.9 Friday, October 3, 2025 Page 1 of 1            TT RR AA NN SS MM II TT TT AA LL FROM::Sandra D. Lemke, ATO-704 TO:: Meredith Guhl ConocoPhillips Alaska, Inc. AOGCC P.O. Box 100360 330 W. 7 th Ave., Suite 100 Anchorage AK 99510-0360 Anchorage, Alaska 99501 RE: Schlumberger Wireline Backlog – Kuparuk River Unit DATE: 12/19/2023 Transmitted: North Slope, Kuparuk River Unit Via hard Drive data drop 1H-111 50-029-23581-00 217133_1H-111_IPROFWFL_03JUL2023 1H-114 50-029-23584-00 217136_1H-114_IPROF_17Oct23 1H-115 50-029-23605-00 218053_1H-115_IPROF RSTWFL_09May2022 1H-116 50-029-23594-00 218012_1H-116_IPROFWFL_05Jul2023 1H-117 50-029-23602-00 218032_1H-117_PPROF-WFL_06July23 218032_1H-117_WFL_18Oct23 1H-119 50-029-23591-00 217178_1H-119_WFL_07Jul2023 1J-102 50-029-23317-00 206110_1J-102_RPPG_18Jul2023 1J-107 50-029-23366-00 207107_1J-107_PPROF_10May2022 1J-162 50-029-23360-00 207080_1J-162_LDL_03May2022 1J-170 50-029-23310-00 206062_1J-170_Temp-Pres_11Jul2023 1J-176 50-029-23364-00 207099_1J-176_LDL_11May2022 4of 12 Transmittall instructions: please promptly sign, scan, and e-mail to Sandra.D.Lemke@conocophillips.com Receipt: Date: Alaska/IT-Support Services GGRE |ConocoPhillips Alaska |Office: 907.265.6947; Mobile 907.440.4512 T38340 T38341 T38342 T38344 T38343 T38345 T38346 T38347 T38348 T38349 T38350 2/29/2024 1H-117 50-029-23602-00 218032_1H-117_PPROF-WFL_06July23 218032_1H-117_WFL_18Oct23 Kayla Junke Digitally signed by Kayla Junke Date: 2024.02.29 11:34:11 -09'00' WELL NAME API #SERVICE ORDER # FIELD NAMESERVICE DESCRIPTIONDELIVERABLE DESCRIPTION DATA TYPEDATE LOGGEDCOLOR PRINTS CDsCD5-1950103207600000 CRU WLSetting RecordFINAL FIELD3-Aug-21CD5-1950103207600000 CRU WLSetting RecordFINAL FIELD11-Aug-21CD5-9650103208110000 CRU WLPERFFINAL FIELD21-Jul-21CD2-31050103208260000 CRU WLDCSTFINAL FIELD16-Sep-21CD2-31050103208260000 CRU WLUSITFINAL FIELD24-Aug-21CD2-31050103208260000 CRU WLUSITFINAL FIELD25-Aug-21CD5-3150103208280000 CRU WLPERFFINAL FIELD27-May-21CD1-01A50103202990100 CRU WLRSTFINAL FIELD12-Sep-21MT7-0650103208310000 GMTU WLCORROSIONFINAL FIELD3-Oct-21MT6-0850103207720000 GMTU WLPSRFINAL FIELD14-Sep-21MT6-0850103207720000 GMTU WLPSRFINAL FIELD22-Oct-21MT7-0650103208310000 GMTU WLMECH CUTTERFINAL FIELD2-Sep-21MT7-0650103208310000 GMTU WLUSITFINAL FIELD12-Dec-21MT7-0650103208310000 GMTU WLUSITFINAL FIELD16-Dec-21MT7--0150103208320000 GMTU WLSCMTFINAL FIELD15-Nov-21MT7-0650103208310000 GMTU WLUSITFINAL FIELD19-Feb-21Lookout 150103203590000 GMTU WLRSTFINAL FIELD29-Mar-21Lookout 150103203590000 GMTU WLRSTFINAL FIELD2-Apr-21Delivery Receipt______ďďLJĞůů_____X_______________________________________Print Name Signature DatePlease return via courier or sign/scan and email a copy to Schlumberger.A Delivery Receipt signature confirms that a package (box, envelope, etc.) has been received. The package will be handled/delivered per standard company reception procedures. The package's contents have not been verified but should be assumed to contain the above noted SLB Auditor-Originated:PTS - PRINT CENTER600 E 57th Pl - Ste AAnchorage, AK 99518Delivered to:AOGCCATTN: Natural Resources Technician333 W. 7th Ave., Suite 100Anchorage, AK 99501-3539Transmittal Date:20-Dec-21Transmittal #:________________Signature12/21/2021Wd͗ϮϭϴϬϯϮϬͲ^Ğƚ͗ϯϲϮϲϳJRBy Abby Bell at 1:43 pm, Dec 21, 2021 1H-11950029235910000 KRU WLIPROFFINAL FIELD24-Jun-211H-11750029236020000 KRU WLIPROFFINAL FIELD16-Jun-213H-31A50103202050100 KRU WLCUTTERFINAL FIELD31-Jul-213S-61150103207740000 KRU WLCUTTERFINAL FIELD11-Oct-211R-10150029214040300 KRU WLSAMPLINGFINAL FIELD30-Jun-213H-3750103208220000 KRU WLGLSFINAL FIELD29-May-213F-0450029214490000 KRU WLIPROFFINAL FIELD23-Feb-211J-10150029232860000 KRU WLPPROFFINAL FIELD2-Mar-211D-0250029204290000 KRU WLIPROFFINAL FIELD17-Feb-21MP-150029205730000 KRU WLPERFFINAL FIELD18-Feb-21MP-150029205730000 KRU WLPERFFINAL FIELD20-Feb-21MP-150029205730000 KRU WLSCMTFINAL FIELD28-Mar-211G-0250029208130000 KRU WLIPROFFINAL FIELD1-Apr-211C-19050029231360000 KRU WLIPROFFINAL FIELD30-Oct-212L-31850103206810000 KRU WLIPROFFINAL FIELD24-Jul-21 MEMORANDUM State of Alaska Alaska Oil and Gas Conservation Commission TO:Jim Regg DATE: Friday, August 6, 2021 `� P.I. Supervisor gn' �) 14Z�Zf SUBJECT: Mechanical Integrity Tests ConocoPhillips Alaska, Inc. 1H-117 FROM: Bob Noble KUPARUK RIV UNIT 1H-117 Petroleum Inspector Sre: Inspector Reviewed By: P.I. Supry— NON-CONFIDENTIAL Comm Well Name KUPARUK RIV UNIT 1H-1 17 API Well Number 50-029-23602-00-00 Inspector Name: Bob Noble Permit Number: 218-032-0 Inspection Date: 8/2/2021 Insp Num: mitRCN210802132103 Rel Insp Num: Packer Depth Pretest Initial 15 Min 30 Min 45 Min 60 Min Well_ --- 1H-117 — - - — - - --- Type Inj W - TVD 3669 Tubing 1075, 1075 1075- 1075 pTD zlso32o Type Test SPT Test psi, 1500 IA 490 1810 - 1730 1720- BBL Pumped: 0.7 -, BBL Returned: 0.7 OA 80 160. 160 160 Interval 4YRTST p/F L P ✓ Notes: Friday, August 6, 2021 Page 1 of 1 Originated:Delivered to:8-Jan-21 Halliburton Alaska Oil and Gas Conservation Comm. Wireline & Perforating Attn.: Natural Resource Technician Attn: Fanny Haroun 333 West 7th Avenue, Suite 100 6900 Arctic Blvd.Anchorage, Alaska 99501 Anchorage, Alaska 99518 Office: 907-275-2605 FRS_ANC@halliburton.com The technical data listed below is being submitted herewith. Please address any problems or concerns to the attention of the sender above WELL NAME API #SERVICE ORDER #FIELD NAME JOB TYPE DATA TYPE LOGGING DATE PRINTS #DIGITAL # 1 1A-01 50-029-20590-00 n/a Kuparuk River Packer Setting Record Field- Final 6-Dec-20 0 1 2 1A-01 50-029-20590-00 n/a Kuparuk River Packer Setting Record Field- Final 7-Dec-20 0 1 3 1C-25 50-029-22941-00 906866139 Kuparuk River Packer Setting Record Field- Final 15-Dec-20 0 1 4 1H-108B 50-029-23608-02 906811421 Kuparuk River Water Flow Record Field- Final 12-Nov-20 0 1 5 1H-109 50-029-23595-00 906810847 Kuparuk River Injection Profile Field & Processed 14-Nov-20 0 1 6 1H-111 50-02923581-00 906831134 Kuparuk River Injection Profile Field & Processed 21-Nov-20 0 1 7 1H-115 50-029-23605-00 906832402 Kuparuk River Injection Profile Field & Processed 23-Nov-20 0 1 8 1H-117 50-029-23602-00 906810277 Kuparuk River Injection Profile Field & Processed 20-Nov-20 0 1 9 1J-118 50-029-23337-00 906798402 Kuparuk River Plug Setting Record Field- Final 1-Nov-20 0 1 10 1Y-19 50-029-22391-00 906849383 Kuparuk River Leak Detect Log Field- Final 7-Dec-20 0 1 PLEASE ACKNOWLEDGE RECEIPT BY SIGNING AND RETURNING A COPY OF THE TRANSMITTAL LETTER TO THE ATTENTION OF: Fanny Haroun, Halliburton Wireline & Perforating, 6900 Arctic Blvd., Anchorage, AK 99518 FRS_ANC@halliburton.com Date:Signed: Transmittal Date: Received by the 01/08/2021 01/11/2021 Abby Bell PTD: 2180320 E-Set: 34544 Originated: Schlumberger PTS - PRINT CENTER 6411 A Street Anchorage, AK 99518 (907)273-1700 main (907)273-4760fax Delivered to: Y AOGCC ;,, ATTN: Natural Resources Technician II ` I— Alaska Oil & Gas Conservation Commision * 333 W. 7th Ave, Suite 100 -y Anchorage, AK 99501 218032 31482 15 -Nov -19 15Nov19JW 03 Schlumberger -Private Originated: Schlumberger PTS-PRINTCENTER 6411 A Street Anchorage, AK 99518 (907)273-1700 main (907)273-4760fax Delivered to: AOGCC ATTN: Natural Resources Technician II Alaska Oil & Gas Conservation Commision 333 W. 7th Ave, Suite 100 j& Anchorage, AK 99501 :1 32 1 ' 86 7RANSMnTAL GATE 12JuII9 -10. TRANSMITTALa A Transmittal Receipt signature confirms that a package (box, (J 6(/ envelope, etc.) has been received and the contents of the X package have been verified to match the media noted above. - Name Signature Date specific content of the CDs and/or hardcopy prints may or may e return via courier or sign/scan and email a copy Schlumber er and CPAL not have been verified for correctness or quality level at this g point. a PTSPri ntCenter(cilslb com Tom Oste rkamoCo�conocoohillins com SLB Auditor- --I--LT Schlumberger -Private SERVICE ORDER DELIVERABLE DESCRIPTION DATA TYPE DATELOGGED Prints CD's 1A-25 30-11 3K-23 50-029.22116-00 50-029-21676-00 50-029-22771.00 EBNL-00028 EBNL-00029 _UB NL -00030 KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER WL WL WL PPROF LDL LDL FINAL FIELD FINAL FIELD FINAL FIELD 21 -Jun -19 22 -Jun -19 23 -Jun -19 1 1 1 2V•02 1Y-14 1H-109 1H-113 1 H-117 3H -14B 50-029-21037-00 50-029-20910-00 50.029-23595.00 50-029-23588-00 50.029-23602-00 50.103-20092.02 EBNL-00034 EBNL-00035 _ENL -00036 EBNL-00037 EBNL-00038 EOSH-00062 KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER WL WL WL WL WL WL ]PROF (PROF IPROF (PROF [PROF LDL FINAL FIELD FINAL FIELD FINAL FIELD FINAL FIELD FINAL FIELD FINAL FIELD 27 -Jun -19 28 -Jun -19 29 -Jun -19 30 -Jun -19 1 -Jul -19 3 -Jul -19 1 1 1 1 1 1 2G -14A 1B -O6 18-09 3G-03 1R -22A 50.029.21161-01 50.029-20603.00 50.029-20655-00 50.103-20245.00 50-029.22206-01 EOSH-00064 EOSH-00065 EOSH-00066 EOSH-00067 EOSH-00048 KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER KUPARUK RIVER WL WLJul•19 WL WL WL LDL PPROF IPROF PPROF LDL FINAL FIELD FINAL FIELD FINAL FIELD FINAL FIELD FINAL FIELD 5- 6 -Jul -19 7 -Jul-19 8 -Jul -19 8 -Jul -19 1 1 1 1 1 G LE 01 1 JUL 12 2pj--- 14 A Transmittal Receipt signature confirms that a package (box, (J 6(/ envelope, etc.) has been received and the contents of the X package have been verified to match the media noted above. - Name Signature Date specific content of the CDs and/or hardcopy prints may or may e return via courier or sign/scan and email a copy Schlumber er and CPAL not have been verified for correctness or quality level at this g point. a PTSPri ntCenter(cilslb com Tom Oste rkamoCo�conocoohillins com SLB Auditor- --I--LT Schlumberger -Private ConocoPhillips Alaska P.O. BOX 100360 ANCHORAGE, ALASKA 99510-0360 May 6; 2019 Commissioner Hollis French Alaska Oil & Gas Commission 333 West P Avenue; Suite 100 Anchorage, AK 99501 Commissioner Hollis French: CR iY-03a MAY 0 S 2019 A®CCC Enclosed please find a spreadsheet with a list of wells from the Kuparuk field (KRU). Each of these wells was found to have a void in the conductor. These voids were filled with cement if needed and corrosion inhibitor, engineered to prevent water from entering the annular space. As per previous agreement with the AOGCC, this letter and spreadsheet serves as notification that the treatments took place and meets the requirements of form 10-404, Report of Sundry Operations. The attached spread sheet presents the well name, top of cement depth prior to filling and volumes used on each conductor. Please call Roger Winter or Roger Mouser at 907-659-7506, if you have any questions. Sincerely, Roger Winter ConocoPhillips Well Integrity Field Supervisor ConocoPhillips Alaska Inc. Surface Casing by Conductor Annulus Cement, Corrosion inhibitor, Sealant Top -off Report of Sundry Operations (10.404) Kuparuk Field Date 6/6/2019 11 & 1H Well Name API # PTD # Initial top of cement Vol. of cement pumped Final top of cement Cement top off date Corrosion inhibitor Corrosion inhibitor/ sealant date ft bbls ft al U-180 50029233290000 2061500 20'9" 2.80 1'5" 5/4/2019 5 5/5/2019 1H-101 50029235850000 2171380 2'10" 0.70 9" 5/4/2019 2.2 5/5/2019 1H-102 50029235800000 2170970 2'9" 0.65 8" 5/4/2019 1.7 5/5/2019 1H-103 50029235930000 2180030 2'2.5" 0.45 9" 5/4/2019 2.2 5/5/2019 11-1-104 50029236100000 2180840 2'.5" 0.40 9" 5/4/2019 2.2 5/5/2019 1H-1086 50029236080200 2180820 3'8" 0.80 10" 5/4/2019 2.5 5/5/2019 1H-109 50029235950000 2180130 2'3" 0.40 9" 5/4/2019 2.2 5/5/2019 1H-110 50029236010000 2180310 2'6.5" 0.65 8.5" 5/4/2019 2 5/5/2019 1 H-111 50029235810000 2171330 2' 0.35 9" 5/4/2019 2.2 5/5/2019 11-1-113 50029235880000 2171680 2'1" 0.40 8" 5/4/2019 1.7 5/5/2019 1H-114 50029235840000 2171360 1111" 0.25 7.5" 5/4/2019 1.8 5/5/2019 11-1-115 50029236050000 2180530 22.5" 0.35 8.5" 5/4/2019 2 5/5/2019 1H-116 50029235940000 2180120 17" 0.25 7" 5/4/2019 1.7 5/5/2019 1H-117 50029236020000 2180320 1111" 0.35 7" 5/4/2019 1.7 5/5/2019 1H-118 50029235780000 2170840 2'4" 0.50 8.5" 5/4/2019 2 5/5/2019 IH -119 50029235910000 2171780 3' 0.80 8" 5/4/2019 1.8 5/5/2019 WELL PERMIT CHECKLIST Field & Pool KUPARUK RIVER, WEST SAK OIL - 490150 Well Name: I( RARUK RIV UNIT 1H-117 Program SER Well bore seg ❑ PTD#:2180320 Company CONOCOPHILLIPS ALASKA INC. _ Initial Class/Type SER! PEND GeoArea 890 Unit 11160 On/Off Shore On Annular Disposal ❑ Administration 17 Nonconven, gas conforms to AS31,05.0300. 1.A),(j.2.A-D) _ _ _ _ _ NA ________ _________ 1 Permit fee attached_ _ .. _ _ _ . NA - 2 Lease number appropriate.. _ _ .. _ _ _ _ _ _ ...... Yes _ _ _ ADL0025639, entire wellbore. . ............. 3 Unique well. name and number _ _ _ Yes KRU 1H-117 4 Well located in.a_defiined pool- - - - - - - - - - - - - _ Yes _ _ KUPARUK RIVER,. WEST SAK OIL-- 490150,_ governed by Conservation Order No. 406C. 5 Well located proper distance, from drilling unit boundary. _ _ .. Yes _ _ CO 406C contains no spacing restrictions withrespect to drilling unit boundaries.. - - - 6 Well located proper distance from other wells- - - - - _ Yes _ _ _ _ CO 406C has no interwell spacing restrictions, - - - - - - .. _ .. 7 Sufficient acreage available in drilling unit... _ _ _ Yes 8 If deviated, is wellbore plat included _ _ _ _ _ _ _ .. Yes 9 Operator only affected party.. Yes Wellbore.will be more than 500' from an external property line where ownership or landownership changes. 10 Operator has appropriate bond in force _ _ _ Yes Appr Date 11 Permit can be issued without conservation order. _ Yes PKB 3/27/2018 12 Permit can be issued without administrative approval _ _ Yes 13 Can permit be approved before 15-day wait. _ _ _ _ _ _ _ _ _ _ Yes 14 Well located within area and strata authorized by Injection Order # (put. 10# in.comments). (For. Yes _ _ AI0.2C. 15 All wells.within 1/4 mile area of review identified (For service well only)___ _ _ _ _ _ _ _ _ _ _ _ Yes _ .... KRU 11-1-101, 1H-05._ 111-U. IH-07A, 11-1-14. 16 18 Pre-produced injector. duration of pre production less than 3 montha(For service well only) - . Conductor stringprovided........ _ _ . . . ............ No...... Yes . _ Ben Tolman.(3/27/18) .... _ _ _ 80' conductor set Engineering 19 Surface casingprotects all. known USDWs .. _ _ _ _ _ _ .. _ Yes _ _ Surface casing set to 1826' MD 20 CMT. vol adequate. to circulate on conductor & surf csg . . . ......... . . . . . . . Yes _ _ _ 1M. excess cement 21 CMT. vol adequate to tie-in long string to surf csg_ _ _____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ No. 22 CMT. will cover all known productive horizons . . . . . . . . . ........ No _ _ Productiveintervalwill be cemented. and perforated - - 23 Casing designs adequate for C,. T, B & permafrost . . . . . . . ............... . Yes 24 Adequate tankage or reserve pit _ Yes _ _ Rig has steel tanks; all. waste. to approved disposal wells 25 If a re-drill, has a 10-403 for abandonment been approved .. _ NA 26 Adequate wellbore separation proposed _ _ _ _ _ _ _ Yes And-collision analysis complete; 1 H-05 fails major risk and is P&A'd 27 if diverter required, does it meet regulations. _ _ _ _ ... Yes _ _ Diverter route and design meets regulations. Appr Date X28 Drilling fluid program schematic & equip list adequate_ _ _ _ _ _ _ _ _ Yes Max formation pressure is 1750 psig(8.6 ppg EMW ); will drill w/. 8.8-10.0 ppg -EMW .... VTL 4/19/2018 '29 BOPEs, do they meet regulation - - - - - - - - _ ... _ _ Yes 30 BOPE.press rating appropriate; test to (put prig in comments). _ _ _ Yes MPSP is 1359 psig; will test BOPs to 3500_psig 31 Choke manifold complies w/API RP-53 (May 84).. .... _ _ Yes 32 Work will occur without operation shutdown- _ _ _ _ _ _ _ _ _ Yes _ _ _ _ _ _ _ _ ...... . . . . . .... . . . . _ .... _ 33 Is presence of H2S gas probable _ ___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Yes _ H2S measures required 34 Mechanical_ condition of wells within AOR verified (For service well only) .......... Yes _ _ _ . 1H-07A;. WSak below SC shoe; Gas injection not approved at this time. 35 Permit can be issued w/o hydrogen sulfide measures _ _ _ _ _ _ _ _ _ _ _ No. H26 measures required. - - - - - _ _ _ _ _ Geology 36 Data presented on potential overpressure zones .. Yes ..... Maximum potential. reservoir pressure is 8.6 ppg EMW; will be drilled using 8.8 to 10.0 ppg mud. Appr Date 37 Seismic analysis of shallow gas zones_ _ _ ..... _ . . ........... NA PKB 3/27/2018 38 Seabed condition survey off-shore) ... ------------- --------------- � NA _ _ _ _ _ _ _ _________ - - .. ---- --- 39 Contact name/phone for weekly-prograss reports_ [exploratory only] ......... _ _ _ NA _ _ _ _ Onshore service well to be drilled........ Geologic Engineering Public Commissioner: Dat m' loner: atemissio y�to 4e �lzs),�