Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAbout183-150 ge Project Well History File~er Page XHVZE This page identifies those items that were not scanned during the initial production scanning phase. They are available in the original file, may be scanned during a special rescan activity or are viewable by direct inspection of the file. ~ g -,~- _~ ~{~ Well History File Identifier RESCAN DIGITAL DATA OVERSIZED (Scannable) [] Color items: [] Diskettes, No. [3 Maps: [] Grayscale items: [] Other, No/Type [] Other items scannable by large scanner [] Poor Quality Originals: OVERSIZED (Non-Scannable) [] Other: -' ,,~ Logs of various kinds NOTES: [] Other BY: BEVERLY BREN VINCENT SHERYL MARIA LOWELL DATE: /S/ Project Proofing BY: BEVERLY BREN VINCENT SHERYL MARIA LOWELL DATE: /S/ Scanning Preparation x 30 = + = TOTAL PAGES PAGE COUNT FROM SCANNED FILE: PAGE COUNT MATCHES NUMBER IN SCANNING PREPARATION: '~ YES Stage 2 IF NO IN STAGE 1, PAGE(S) DISCREPANCIES WERE FOUND: YES BY: BEVERLY BREN VINCEN~ MARIA LOWELL (SCANNING I$ COMPLETE AT THIE POINT UNLESS SPECIAL ATTENTION 18 REQUIRED ON AN INDIVIDUAL PAGE BASIS DUE TO QUALITY. GRAYSCALE OR COLOR IMAGES) Production Scanning Stage 1 NO NO RESCANNEDBY; BEVERLY BREN VINCENT SHERYL MARIA LOWELL DATE: /S/ General Notes or Comments about this file: Quality Checked (do.el Memorandum To: Re: State of Alaska Cancelled or Expired Permit Action EXAMPLE: Point McIntyre P2-36AXX API# 029-22801-95 Oil and Gas Conservation Commission This memo will remain at the front of the subject well file. Our adopted conventions for assigning APl numbers, permit numbers and well names did not specifically address expired or cancelled permits. This omission has caused some inconsistencies in the treatment of these kinds of applications for permit to ddll. Operators have asked us to adopt formal procedures for this class of permit application in order to prevent future database disparities. If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain unchanged. The APl number and in some instances the well name reflect the number of preexisting reddlls and or muitilaterals in a well. In order to prevent confusing a cancelled or expired permit with an active well or multilateral these case sensitive well identifiers will be changed for expired and cancelled applications for permits to ddll. The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95. The well name for a cancelled or expired permit is modified with an appended xx. These procedures are an addendum to the APl numbering methods described in AOGCC staff memorandum "Multi-lateral (wellbore segment) Ddlling Permit Procedures, revised December 29, 1995. AOGCC database has been changed to reflect these changes to this permit. Statistical Technician SOHIO ALASKA PETROLEUM COMPANY 3111 "C" STREET ANCHORAGE, ALASKA TELEPHONE (907) 276-5111 MAIL: POUCH 6-612 ANCHORAGE, ALASKA 99502 November 2, 1983 Alaska Oil & Gas ConserVation Cc~mission 3001 Porcupine Drive Anchorage, Alaska 99502 Attn: Mr. C. V. Chatterton Gentlemen: W~',T'; K-5 '(14-04-.11-14)' PBU Permit No..83-150 Sur. Loc. 2146'SNL, 504'~{L, Sec. 4, TllN, R14E, UPM Btmhole Loc. 829 'NSL, 1222 '~, Sec. 4 , TllN, R14E, UPM Pursuant to our conversation this date, this is to advise that the above-named permitted Well K-5 will not be drilled and we wish to cancel thiS permit. If you have any questions, please call Ted Stagg at 263-5173. Very truly yours, District Drilling Engineer cc: Well File #17 Geology October 12, 1983 Mr. R. H. Retley District Drilling Engineer Sohio Alaska Petroleum Company Pouch 6-612 Ancl~orage, Alaska '99502 Re ~ Prudhoe Bay Unit K-5 Sohio Alaska Petroleum Company Permit No. 83-150 Sur. Loc. 2146'SNL, 504'EWL, Sec. 4, TllN, ~.14E, UPM. Btmhole Loc. 829'NSL, 1222'EWL, Sec. 4, TllN, R14E, Dear Mr. Reiley~ Enclosed is the approved application for permit to drill the above, referenced well. If coring is conducted, a one cubic inch chip from each foot of recovered core is required. Samples of well cuttings and a mud log are not required. A.continuous directional survey is required as per 20 AAC 25.050(b)(5). If available, a tape containing the digitized log information shall be submitted om all logs for copying except experimental logs, velocity surveys and dtpmeter surveys. Many rivers in Alaska and their drainage systems have been classified as important for the spa~ming or migration of anadromous fish. Operations in these areas are subject to AS 16.05.870 and the regulations promulgated thereunder (Title 5, Alaska Administrative Code). Prior to com~encin~ operations.you may be contacted by the Habitat Coordinator's Office, Departmeht of Fish and Game. Pollution of any waters of the State is prohibited by AS 46, ~apter 3, Article 7 and the regulations promulgated thereunder (Title 18, Alaska Administrative Code, Chapter 70) and by the Federal [~ater Pollution Control Act, as amended. Prior to c~]encing operations you may be contacted by a representative of the Department of Environraental Conservation. To aid us in scheduling field work, please notify this office 24 hours prior to commencing installation of the blowout ~ir. R. H. Reiley Prudhoe Bay Unit K-5 -2- October 12, 1983 prevention equipment so that a representative of the Con~nission may be present to witness testing of the equipment before the surface casing shoe is drilled. ~ere a diverter system is required, please also notify this office 24 hours prior to c~mencing equipment installation so that the Commission ~y witne~ testing befo~ drilling below the shoe of the conductor pipe. In th~ event of suspension or abandonment, please give this office adequate advance notification ~o that we may have a ~i thews present. Very truly y~s, C V. Chatterton ~airman of Alaska Oil and Gas COnservation Co~ission . be:6..H/A Enclosure cc~ Department of Fish & Game, Habitat Section w/o encl. Department of Environmental Conservation w/o encl. SOHIO ALASKA PETROLEUM COMPANY 3111 "C" STREET ANCHORAGE, ALASKA TELEPHONE (907) 276-5111 MAIL: POUCH 6-612 ANCHORAGE, ALASKA 99502 October 7, 19 83 Alaska Oil & Gas Conservation Co~mission 3001 Porcupine Drive Anchorage, Alaska 99501 Attn: Mr. C. V. Chatterton Gentlemen: WELL K-5 (14-04-11-14) PBU Enclosed are the following documents, in triplicate, along with our check for $100.00 to cover the permit filing fee. 1. Application for Permit to Drill; 2. Proposed Blowout Prevention Diagram; 3. Surveyor's plat showing well location; 4. Proposed drilling program outline; 5. Directional map. If you have any questions, please call Ted Stagg at 263-5173. Yours very truly, District Drilling Engineer RHR: MCM: ckg encs cc: Well File ~17 STATE OF ALASKA ALASKA ~.,L AND GAS CONSERVATION CC.:.,MISSION PERMIT TO DRILL 20 AAC 25.005 la. Type of work. DRILL REDRILL DEEPEN lb. Type of well EXPLORATORY [] DEVELOPMENT OIL IX] DEVELOPMENT GAS [] SERVICE [] STRATIGRAPFIIC [] SINGLE ZONE :~] MULTIPLE ZONE [] 2. Name of operator Sohio Alaska Petroleum Company 3. Address Pouch 6-612, Anchorage, Alaska 99502 4. Location of well at surface 2146' SNL, 504' EWL, Sec. 04, TllN, R14E, UPM Attopofproposedproducinginterval (target) 900' NSL, 1200' EWL, Sec. 04, TllN, R14E, UPM At total depth 829' NSL, 1222' EWL, Sec. 04, TllN, R14E, UPM 5. Elevationinfeet(indicateKB, DFetc.) Est. KBE = 60' AMSL I 6. Lease designation and serial no. AD% 28303 9. Unit or lease name Prudhoe Bay Unit 10. Well number K~5 (14-04-11-14) PBU 11. Field and pool Prudhoe Bay Prudhoe Oil Pool 12. Bondinformation(see20AAC25.025) Type Blanket Suretyand/ornumber Safeco Ins. 2975387 Amount $200~000.00 13. Distance and direction from nearest town NW of Deadhorse 10miles t6. Proposed depth (MD & TVD) 9366' MD- 8882 TVDfeet 14. Distance to nearest property or lease line East of ADL 28304 - 1200feet 17. Number of acres in lease 2560 19. If deviated (see 20 AAC 25.050) 23° 17' 120. Anticipated pressures KICK OFF POINT 2800 feet. MAXIMUM HOLE ANGLE I (see 20 AAC 25'035 (c) (2) 15. Distance to nearest drilling or completed SE well E-17 2100 feet 18. Approximate spud date November 15 ¢ 1983 3300 psig@ Surface 4390 psig@8800 ft./¢¢ (TVD) 21 Proposed Casing, Liner and Cementing Program SETTING DEPTH QUANTITY OF CEMENT SIZE Hole Casing % 13 3/8 12¼ 9 5/8 8% 7 Weight Insulat 72# CASING AND LINER Grade Coupling :ed Con( uctor L-80 Butt L-80 Butt L-80 Butt 47# 26# 22. Describe proposed program: Length 8O 2650 8536 1050 MD TOP TVD Surf&ce Surf4ce Surface I 8316 I 7917 i MD BOTTOM TVD 1101 110 26801 2680 85661 8147 I 936611 8882 (include stage data) 8 cu.¥ds, concrete 3746 cu.ft. PF E & PF 1893 cu.ft. Class G; 130 cu.ft. Permafros' 302 cu.ft. Class G w/18% salt See attached proposed drilling and completion program. 23. I hereby certify that the foregoing isJ, r./~ and correct to the best of my knowledge ~ '1 ~ A ~ ) _ ~ District,° 7 Drilling Engineer ~IhGeNspEaDc f~2C ~ R~. H. Reiley TITLE DATE e,ow o . CONDITIONS OF APPROVAL Samples required I-lYES '~0 Permit number Form 10-401 Mud log required []YES ~10 Approval date Rev. 7-1-80 Directional Survey required ~.¥ ES [-]NO SEE COVER LETTER FOR OTHER REQUIREMENTS ,COMMISSIONER DATE October 12, 1983 by order of the Commission Submit in triplicate s II C B.O.P. ~TACK CONFIGURA-TION IL · 15 5/8" TRIPLE RAM STACK i 5000 PSi WP DRILLING ANNULAR PREVENTER PIPE RAMS BLIND RAMS CHECK KILL LINE HAND GATE DRILLING SPOOL GATE GATE PIPE RAMS CHOKE LINE B.O.P.~-STACK CONFIGUR,~.~TION i 5/8" TRIPLE RAM STACK 5000 PSI WP DRILLING I ANNULAR PREVENTER PIPE RAMS BLIND RAMS 2" KILL LINE DRILLING SPOOL CHECK GATE GATE GATE L PIPE RdMS I I CHOKE LINE HYDR. ASST. GATE . ~ ~ '~ I II . III II I I I I i~ I lo' ..... +,1 ....... -' ...... +-', -- -~o° ....... '~--+o° o'll ..... ~ . ~ _ 80 . ·_ . , 104I m I II [~ (Proposed)- ~ I ~]~W~LL K~(AS ~TAKED) -- I : ' ' - t~ ~ ~ LAT= 70°gO'~l.ll'' i ' I I ~~ LONG=I48° 00' I ~ ~ X= 671,350 { Pr o~sedF 02 I OI I I iL_ ! 2oo'_ K: 1, iT_._(?r°F°sed) + PAD DETAIL SCALE: I": 500' PORTION OF ~T. II ~ 12 N.,R. 14 E.,U.M SCALE: I" : I/2 MILE SURVEYOR'S CERTIFICATE I HEREBY CERTIFY THAT i AM PROPERLY REGISTERED AND LICENSED TO PRACTICE LAND SURVEY!NG IN THE STATE OF ALASKA, THAT THIS PLAT REPRESENTS A LOCATION SURVEY OF THE WELLPAD SHOWN AND THE WELLS THEREON. THIS SURVEY WAS MADE BY ME OR UNDER MY DIRECT SUPERVISION, AND ALL DIMENSIONS AND OTHER DETAILS ARE CORRECT. BOTTOM HOLE LOCATIONS ARE FURNISHED BY OTHERS. DATE _--.-~""'~_/..~L./~'_ 3. REGISTRATION NO. __L REGISTERED LAI(I~ SURVEY~)R REVISE K-5 ADDED BHL REVISE K- 3 ADD ,' .:,:_,~,.;¥r7~ 9/l 2 /83 REVISE K-4 ADDED BHL ~,-,~9/12/85 REVISE K-3 ADD K-ZA REVISE K-2 ADO PROPOSED BHL ?-- 8/18/83 REVISE K-I SURFACE LOC. FROM PROPOSED TO AS-STAKED. REVISE K-I BHL. (AS-STAKED) PAD "K" Located In NW I/4 PROTRA. CTED SEC.: ..4~T.. IIN.,R.14E.,UMIAT MER.,ALA__S. KA Surveyed for SOHIO ALASKA PETROLEUM CO, Surveyed by OCEAN TECHNOLOGY LTD. LAND & HYDROGRAPHIC SURVEYOt~S 2502 West N0rfhern Llghtm,B0ulevord Anchorage, Alaska A:12847- I IO ~o ~ 3o 4G ~_ IO ~o 3o 4o $ IO -- i 40 + K-II ..... t- ' I .... : ..... - ......... i'*' ~- .......... (P~.~)p~-s~'~ ...... (Proposed) 1°2: I I i : I i I "--oa / I ' ~ ' I ~ ~ ~' I ..~ ,, , ,,, ,,,,, 02 I I 00' ! ~: "~ X= I . ' ~ t O~ I I~ I ~ K~-5 04 I b~ (ProposedJ ' ~: PAD DETAIL ol I I -! ....... 1 I o2 ! I o$ I I I I I SCALE: I''= 500' o~PORTION OF I T. II 8~ 12 N.,R. 14 E.,U.M SCALE: I : I/2 MILE SURVEYOR'S CERTIFICATE ! HEREBY CERTIFY THAT ! AM PROPERLY REGISTERED AND LICENSED TO PRACTICE LAND. SURVEYING IN THE STATE OF ALASKA, THAT THIS PLAT I~IEPRESENTS A LOCATION SURVEY OF THE WELLPAD SHOWN AND THE WELLS THEREON. THIS SURVEY WAS MADE BY ME OR UNDER MY DIRECT SUPERVISION, AND ALL DIMENSIONS AND OTHER DETAILS' ARE CORRECT, BOTTOM HOLE LOCATIONS ARE FURNISHED BY OTHERS. REVISE K-5 ADDED BHL REVISE K-3 ADD REVISE K-4 ADDED BHL REVISE K-:5 ADD K-ZA REVISE K-3 ADDED BHL REVISE K-2 ADD PROPOSED BHL REVISE K- I SURFACE LOC. FROM PROPOSED TO AS-STAKED. REVISE K- I BHL. I III -- II II I I II I Ii (AS-STAKED) PAD "K" Located In NW I/4 PROTRACTED SEC. 4 UMIAT mER. Surveyed for SOHIO ALASKA PETROLEUM CO. Surveyed by OCEAN TECHNOLOGY LTD. LAND & HYDROGRAPHIC SURVEYORS 2502 West Northern Lights.Boulevard Anchoroge, Alaska A~12847- 83 PROPOSED DRILLING AND CO>~PI~E'i'ION ]'RO(:RAM WELL K-5 (14-04-11-14) PBU Install and cement 80' of 20" x 30" insulated conductor to surface. Drill 17 1/2" bole to 2700' TVD and cement 13 3/8" 72# L-80 Buttress casing to surface. Install blowout prevention equipment consisting of 5000 psi W.P. pipe rams, blind rams, and annular preventer. Maximum possible bottomhole pressure is 4390 psi at 8800' TVDss based on original reservoir pressure. possible surface pressure is 3330 psi based on a gas column to surface from 8600' TVDss and an oil column to 8800' TVDss. Directionally drill 12 1/4" bole to +100' R~VD above the Sag River Sandstone. Run 9 5/8" 47# L-80 Buttress casing t--o within 5' of 12 1/4" TD and cement in two stages: First stage using Class G cement around the 9 5/8" shoe and a second stage using Arctic Pack followed by 130 cu.ft, permafrost cement dis- placed through a D.\~. packer collar set 80' above the 13 3/8" shoe. Directionally drill 8 1/2" hole to TD. Run 7" liner from TD to 250' inside 9 5/8'~ casing shoe and cement using Class G cement with 18% salt. Clean out to 7'2 float equipment. Change over to 9.6 ppg. NaC1 completi, on fluid. Test casing and lap to 3000 psi, Run CBL, " Run 9 5/8" production packer on internal plastic coated tubing with gas lift mandrels and a sliding sleeve. Set packer_+50' above top of liner. A sub- surface safety walve witI5 dual control lines will be placed +--50' below base of permafrost. Install and test %~as tree. Displace tubing to diesel, Set and test' packer. Suspend well for perforation subsequent to rig release. Tubing Size; 4 1/2" 12.6f! L-80 AB-mod. Butt. IPC (potential straddle-pack completion) PROI'OSED DRILl. lNG AND CO>I]'].E'J']ON ]'ROb:RAM WELL K-5 (14-04-11-1/L)~_ PBU Install and cement 80' of 20" x 30" insulated cond,ctor to surface. Drill 17 1/2" hole to 2700' R~VD and cement 13 3/8" 72# L-80 Buttress casing to surface. Install blowout prevention equipment consisting of 5000 psi W.P. pipe rams, bl~nd rams, and annular preventer. Ma~,imum possible bottomhole pressure is 4390 psi at 8800' TVDss based on original reservoir pressure. possible surface pressure is 3330 psi based on a gas coltish to surface from 8600' TVDss and an oil column to 8800' TVDss. Directionally drill 12 1/4" hole to +100' RnTD above the Sag River Sandstone. Run 9 5/8" 47# L-80 Buttress casing to within 5' of 12 1/4" TD and cement in two stages: First stage using Class G cement around the 9 5/8" shoe and a second stage using Arctic Pack followed by 130 cu. ft. permafrost cement dis- placed through a D.¥. packer collar set 80' above the 13 3/8" shoe. Directiona]ly drill 8 1/2" hole to TD. Run 7" l~ner from TD to 250' inside 9 5/8" casing shoe and cement using Class G cement with 18% salt. Clean out to 7" float equipment. Change over to 9.6 ppg. NaC1 completion fluid. Test casing and lap to 3000 psi. Run CBL, Run 9 5/8" production packer on interna.1 p]a. stic coated tubing with gas lift mandrels and a sliding sleeve. Set packer +--50' above top of liner. A sub- surface safety ~alve witB dual control lines will be placed +--50' below base of permafrost. Install and test ]irnas tree. Displace tubing to diesel, Set and test' packer. Suspend well for perforation subsequent to rig release. Tubing Size; 4 1/2" 12.6# L-80 AB-mod. Butt. IPC ~potential straddle-pack completion) ')' ITEM'i' APPROVE DATE · (1). Fee /'0-!'"~ · /{2 thru 8) . Lease &.Well No. 1. Is the permit fee attached ............. ' ........... 2. Is well to be located in a defined pool ......... '. . 3. Is Well located proper distance from property line . 4. Is well located proper distance from other wells ......... 5. Is sufficient undedicated acreage available in this pool . 6. Is well'to be deviated'and is well bore plat inclu'ded ..'.. '7. Is operator the only affected party ...................... 8. Can permit be approved before ten-day wait ...... ~ ........ YES NO eeeoee®®e®® eeeeeeeleee ®eeeeeeeeee (3) Ad.min~11) (4) Casg ~x~ (12 thru 2.0) 9~ 10. 11. 12~ 13. 14. 15. 16. 17. 18. 19. 20. Does oPerator have a bond in fOrce ........................... Is conservation order needed' ~ a .................................... administrative approval needed Is conductor string provided ........ ~ ....................... ~ ...... Is enOugh cement used to circulat, e on conductor and surface ..... ~... Will cement' tie in surface' and intermediate or production strings .. Will cement cover a%l ,knoWn productive horizons ........... ~''''~ii'' Will surface casing protect fresh water zones ................... Will all casing give adequate safety in collapse, tension and burst. Is this well to be kicked off from an existing wellbore ............. Is old wellbore abandonment procedure included on 10-403 ...... , ..... Is adequate well bore separation proposed ........................... (5) BOPE ~'~ (21 thru 24) 21. 22. 23. 24. Is a diverter system required ....................................... Are necessary diagrams of diverter and BOP equipment attached ....... ~. Does BOPE have sufficient pressure rating - Test to ~z~ psig .. Does the choke manifold comply w/API RP-53 (Feb.78) .................. (6) Add /~'z~,d /~ /! ,.~3 25 Additional requirements ' e° ~ -- · eeeee®eeee®emeeeoemmme®eoeee®oeeooe®e®eeeeeee · g. '/c a REMARKS 0 ~Z ~-~ o Additional Remarks: Geology: Engine .~y ing: ~-VA _~ JK~ HJH rev: 12/06/82 INITIAL GEO'. UNIT ON/OFF POOL CLASS STATUS AREA NO. SHORE