Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutKuparuk River CPF 1 - ConocoPhillips Alaska, IncPercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDispositionVolume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool NamePool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety:MCF13. Other (see instructions)Lease Use:MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation:MCF15. NGL Gas EquivalentWaste:MCF16. Purchased gas1. Facility Number 2. Facility Name3. Field4. Operator5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form 10‐422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov0290000021 Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 01/20251,4832,406,79911016,21223,53069,75102,517,78701,399,8840(467,864)Line 18 Transferred to is volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT490100100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com406/03/2025
PercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDisposition Volume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool Name Pool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety: MCF13. Other (see instructions)Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation: MCF15. NGL Gas EquivalentWaste: MCF16. Purchased gas1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form10Ͳ422Revised10/2021 20AAC25.235SubmitinPDFformattoaogcc.reporting@alaska.gov0290000021Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 01/20251,4832,406,79911016,21223,530-398,11302,049,923001,399,8840 Reinjected vol does not include volumes of PBU fuel gas reflected on line 17. Transferred From = PBU 1,399,884 mcf fuel gas. Line 18 Transferred to is volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT 490100 100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
1/31/2025CONSERVATION ORDER NO. 219GAS FLARING OR VENTING INCIDENTSCPF #1January-2025PLANNEDDATE TIMEVOLUME MSCF DESCRIPTION OF FLARING EVENT UNPLANNEDACTION TAKEN TO MINIMIZE VOLUMEFLARING OR VENTING EVENTS GREATER THAN 1 HOUR0TOTAL OVER 1 HOUR 0Planned > 1 Hour0PLANNED EVENTS LESS THAN 1 HOURFlare or Vent Volumes:Greater than 1 hour 0Less than 1 hour 11Continuous Assist 23,530Pilot and Purge 16,212TOTAL FLARED/VENTED 39,754
March 19, 2025
To: Recipients of Kuparuk River Unit Gas Disposition Reports
Enclosed are copies of the Gas Disposition Reports for KRU CPF1, CPF2 and CPF3
Facilities during February 2025, along with any Gas Flaring or Venting Incident Reports
for volumes flared over one hour.
If you have any questions, please contact Laurie Beavers at (918) 661-8373.
Sincerely,
Laurie Beavers
Laurie Beavers, Analyst
Production & Revenue Accounting
Enclosures
ConocoPhillips
315 Johnstone Avenue
Bartlesville, OK 74004
PercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDispositionVolume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool NamePool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety:MCF13. Other (see instructions)Lease Use:MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation:MCF15. NGL Gas EquivalentWaste:MCF16. Purchased gas1. Facility Number 2. Facility Name3. Field4. Operator5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form 10‐422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov0290000021 Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 02/20259242,195,848170015,26630,61773,58102,316,40601,436,4420(578,427)Line 18 Transferred to is volume transferred to CPF2 437,655 and CPF3 140,772. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT490100100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com406/03/2025
PercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDispositionVolume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool NamePool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety:MCF13. Other (see instructions)Lease Use:MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation:MCF15. NGL Gas EquivalentWaste:MCF16. Purchased gas1. Facility Number 2. Facility Name3. Field4. Operator5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form 10‐422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov0290000021 Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 02/20259242,195,848170015,26630,617-504,59301,738,232001,436,442(253) Reinjected vol does not include volumes of PBU fuel gas reflected on line 17. Transferred From = PBU 1,436,442 mcf fuel gas. Line 18 Transferred to is volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT490100100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
2/28/2025
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #1
February-2025
PLANNED
DATE TIME
VOLUME
MSCF DESCRIPTION OF FLARING EVENT UNPLANNED
ACTION TAKEN TO MINIMIZE
VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
0
TOTAL OVER 1 HOUR 0
Planned > 1 Hour 0
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greater than 1 hour 0
Less than 1 hour 170
Continuous Assist 30,617
Pilot and Purge 15,266
TOTAL FLARED/VENTED 46,053
PercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDispositionVolume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool NamePool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety:MCF13. Other (see instructions)Lease Use:MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation:MCF15. NGL Gas EquivalentWaste:MCF16. Purchased gas1. Facility Number 2. Facility Name3. Field4. Operator5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form 10‐422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov0290000021 Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 03/20258462,493,628310016,03735,58484,57502,630,98001,614,2600(692,264)Line 18 Transferred to is volume transferred to CPF2 495,953 and CPF3 196,311. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT490100100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com406/03/2025
PercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDisposition Volume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool Name Pool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety: MCF13. Other (see instructions)Lease Use: MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation: MCF15. NGL Gas EquivalentWaste: MCF16. Purchased gas1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form10Ͳ422Revised10/2021 20AAC25.235SubmitinPDFformattoaogcc.reporting@alaska.gov0290000021Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 03/20258462,493,628310016,03735,584-111,73502,434,670001,614,260(2,322) Reinjected vol does not include volumes of PBU fuel gas reflected on line 17. Transferred From = PBU 1,614,260 mcf fuel gas. Line 18 Transferred to is volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT 490100 100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
3/31/2025CONSERVATION ORDER NO. 219GAS FLARING OR VENTING INCIDENTSCPF #1March-2025PLANNEDDATE TIMEVOLUME MSCF DESCRIPTION OF FLARING EVENT UNPLANNEDACTION TAKEN TO MINIMIZE VOLUMEFLARING OR VENTING EVENTS GREATER THAN 1 HOUR0TOTAL OVER 1 HOUR 0Planned > 1 Hour0PLANNED EVENTS LESS THAN 1 HOURFlare or Vent Volumes:Greater than 1 hour 0Less than 1 hour 310Continuous Assist 35,584Pilot and Purge 16,037TOTAL FLARED/VENTED 51,931
May 20, 2025
To: Recipients of Kuparuk River Unit Gas Disposition Reports
Enclosed are copies of the Gas Disposition Reports for KRU CPF1, CPF2 and CPF3
Facilities during April 2025, along with any Gas Flaring or Venting Incident Reports for
volumes flared over one hour.
If you have any questions, please contact Laurie Beavers at (918) 661-8373.
Sincerely,
Laurie Beavers
Laurie Beavers, Analyst
Production & Revenue Accounting
Enclosures
ConocoPhillips
315 Johnstone Avenue
Bartlesville, OK 74004
PercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDispositionVolume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool NamePool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety:MCF13. Other (see instructions)Lease Use:MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation:MCF15. NGL Gas EquivalentWaste:MCF16. Purchased gas1. Facility Number 2. Facility Name3. Field4. Operator5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form 10‐422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov0290000021 Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 04/20255272,366,020476015,93834,46490,27502,507,70101,621,2090(749,749) Line 18 Transferred to is volume transferred to CPF2 - 432,279 and CPF3 - 317,470. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT490100100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
4/30/2025
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #1
April-2025
PLANNED
DATE TIME
VOLUME
MSCF DESCRIPTION OF FLARING EVENT UNPLANNED
ACTION TAKEN TO MINIMIZE
VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
0
TOTAL OVER 1 HOUR 0
Planned > 1 Hour 0
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greater than 1 hour 0
Less than 1 hour 476
Continuous Assist 34,464
Pilot and Purge 15,938
TOTAL FLARED/VENTED 50,879
July 16, 2025
To: Recipients of Kuparuk River Unit Gas Disposition Reports
Enclosed are copies of the Gas Disposition Reports for KRU CPF1, CPF2 and CPF3
Facilities during June 2025, along with any Gas Flaring or Venting Incident Reports for
volumes flared over one hour.
If you have any questions, please contact Laurie Beavers at (918) 661-8373.
Sincerely,
Laurie Beavers
Laurie Beavers, Analyst
Production & Revenue Accounting
Enclosures
ConocoPhillips
315 Johnstone Avenue
Bartlesville, OK 74004
0290000021Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 05/20253582,743,958672,44516,82935,54691,44402,890,64601,705,6670(806,993)Reinjected vol does not include volumes of PBU Fuel Gas reflected on line 17. Transferred From = PBU 0 mcf fuel gas. Line 18 Transferred tois volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT 490100 100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
5/31/2025CONSERVATION ORDER NO. 219GAS FLARING OR VENTING INCIDENTSCPF #1May-2025PLANNEDDATE TIMEVOLUME MSCF DESCRIPTION OF FLARING EVENT UNPLANNEDACTION TAKEN TO MINIMIZE VOLUMEFLARING OR VENTING EVENTS GREATER THAN 1 HOUR5/9/202510:59:00 AM - 12:29:00 PM 2,391Overpressure protection from gas lift compressor tripNShut in 28 wells and IGOR cut5/18/202501:04:00 PM - 02:11:00 PM 12Placing T-2201 back into service, needed to purge prevent O2 infiltration to VRUs due to explosionYAllowed enough time to purge O2 from system5/18/202502:31:00 PM - 06:34:00 PM 42Placing T-2201 back into service, needed to purge prevent O2 infiltration to VRUs due to explosionNAllowed enough time to purge O2 from systemTOTAL OVER 1 HOUR 2,445Planned > 1 Hour12PLANNED EVENTS LESS THAN 1 HOURFlare or Vent Volumes:Greater than 1 hour 2,445Less than 1 hour 67Continuous Assist 35,546Pilot and Purge 16,829TOTAL FLARED/VENTED 54,886
PercentComm.Comm.STATE OF ALASKAALASKA OIL AND GAS CONSERVATION COMMISSIONFACILITY REPORT OF PRODUCED GAS DISPOSITIONDispositionVolume MCF20. For production from multiple pools, list contribution of each pool as a percent of Total Volume.6. SoldPool NamePool Code7. Reinjected8. Flared or vented 1 hour or less12. Fuel gas used in lease operationsAOGCC Use OnlyAuthorization >1 hr:9. Flared or vented more than 1 hour (see instr.)10. Pilot and Purge11. Assist GasSafety:MCF13. Other (see instructions)Lease Use:MCF14. TOTAL VOLUME (ITEMS 6-13)Conservation:MCF15. NGL Gas EquivalentWaste:MCF16. Purchased gas1. Facility Number 2. Facility Name3. Field4. Operator5. Month/Year of DispositionReviewed by:COMMISSIONERAuthorized Name and Digital Signature with date:I hereby certify that the foregoing is true and correct to the best of my knowledge.Contact Phone:Contact Email:Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60° F. Authority 20 AAC 25.235.Revision? Date of Revision:Title:19. Remarks:17. Transferred from:18. Transferred to: (Express as a negative #)Form 10‐422 Revised 10/2021 20 AAC 25.235Submit in PDF format toaogcc.reporting@alaska.gov0290000021 Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 06/2025802,769,222328016,51034,55277,42302,898,11601,671,0730(817,036) Reinjected vol does not include volumes of PBU Fuel Gas reflected on line 17. Transferred From = PBU 0 mcf fuel gas. Line 18 Transferred to is volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT490100100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
6/30/2025
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #1
June-2025
PLANNED
DATE TIME
VOLUME
MSCF DESCRIPTION OF FLARING EVENT UNPLANNED
ACTION TAKEN TO MINIMIZE
VOLUME
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
0
TOTAL OVER 1 HOUR 0
Planned > 1 Hour 0
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes:
Greater than 1 hour 0
Less than 1 hour 328
Continuous Assist 34,552
Pilot and Purge 16,510
TOTAL FLARED/VENTED 51,391
0290000021Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 07/20253,2292,413,6797923,82517,59829,119401,82002,870,0620658,8130(252,505)Reinjected vol does not include volumes of PBU Fuel Gas reflected on line 17. Transferred From = PBU 0 mcf fuel gas. Line 18 Transferred tois volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT 490100 100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
7/31/2025CONSERVATION ORDER NO. 219GAS FLARING OR VENTING INCIDENTSCPF #1July-2025PLANNEDDATE TIMEVOLUME MSCF DESCRIPTION OF FLARING EVENT UNPLANNEDACTION TAKEN TO MINIMIZE VOLUMEFLARING OR VENTING EVENTS GREATER THAN 1 HOUR7/19/202509:28:00 AM - 11:17:00 AM 2,371 Overpressure protectionNPlant shut in and they needed to get rid of gas. 7/28/202506:12:00 PM - 07:12:00 PM 602 Overpressure protectionNCut wells7/28/202507:47:00 PM - 09:00:00 PM 762 Overpressure protectionNCut wells7/30/202508:19:00 AM - 10:03:00 AM 90 1E-126 caused plant upset.N1E-126 was shut in to prevent emulsions causing PWTOTAL OVER 1 HOUR 3,825Planned > 1 Hour0PLANNED EVENTS LESS THAN 1 HOURFlare or Vent Volumes:Greater than 1 hour 3,825Less than 1 hour 792Continuous Assist 29,119Pilot and Purge 17,598TOTAL FLARED/VENTED 51,334
0290000021Central Processing Facility #1Kuparuk River Unit CONOCOPHILLIPS 08/20255862,346,89475152317,21635,40660,52402,461,90001,472,6860(648,273)Reinjected vol does not include volumes of PBU Fuel Gas reflected on line 17. Transferred From = PBU 0 mcf fuel gas. Line 18 Transferred tois volume transferred to CPF2. Line 6 is gas sold to KTC.KUPARUKRIVER UNIT 490100 100.00KUPARUK RIVER UNIT WEST SAK4901500.00Analyst, Production & Revenue Accounting (918) 661-8373laurie.beavers@cop.com
8/31/2025CONSERVATION ORDER NO. 219GAS FLARING OR VENTING INCIDENTSCPF #1August-2025PLANNEDDATE TIMEVOLUME MSCF DESCRIPTION OF FLARING EVENT UNPLANNEDACTION TAKEN TO MINIMIZE VOLUMEFLARING OR VENTING EVENTS GREATER THAN 1 HOUR8/11/202503:20:00 PM - 04:31:00 PM 523Overpressure protection. A-GLC 1st stage recycle valve coupling came apart. NWells at CPF1 were shut in to manage flare while valve was repaired. TOTAL OVER 1 HOUR 523Planned > 1 Hour0PLANNED EVENTS LESS THAN 1 HOURFlare or Vent Volumes:Greater than 1 hour 523Less than 1 hour 751Continuous Assist 35,406Pilot and Purge 17,216TOTAL FLARED/VENTED 53,896
0
\
I
0
0
\<
5�
<$
§z
//
<
\)
k
<
/
$
CO
<
[
B
ƒ
/
\
-
7
�
}
}
f
£
o
It
CD
2?
00
N
m
\§
3
N
}\
2
2
7
It
o
7
q
o
n
n
£Nt
)
CN
CN
_
§
§
!
)
)
\
/
}
\
\
\
\
\
\
\
7
w
�
�
N
F
m z
w
N ❑
p U
z z
a (!) N
W z
❑ O
F
�o ZIt
LU
z a E
O
0 U w
c
> O m
Z N
W
N
z g
O LL
U N
Q
W
N
i
z
O w
�- M
Z D
J
Q O
F
z
O
U
Q
n
❑ z
w z
z g
z LL
g z
IL D
z
z
W
w
0
z
g
LL
O
z
O
a_
K
U
fA
w
O
w
H
W
a
0
O O O
0
O
w
W
0
J
F
0
IL
0
O
2
z
Q
2
F
U)
U)
W
J
M
z
z
W
W
w
z
z
o�ovn o
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
River Unit
6.
Sold
994
7.
Reinjected
2,495,172
8.
Flared or vented 1 hour or less
1,164
9.
Flared or vented more than 1 hour (see inslr.)
0
10.
Pilot and Purge
0
18,681
11.
Assist Gas
35,461
12.
Fuel gas used in lease operations
53,463
13.
Other (see instructions)
0
TOTAL VOLUME (ITEMS 6-13) 2,604,936
NGL Gas Equivalent 0-
Purchased gas 1,431,359
Transferred from: 0
Transferred to: (Express as a negative#) (534,724)
CONOCOPHILLIPS
Total Volume.
10/2025
-ach Dool as a
AOGCC Use Only
Authorization 51 hr:
Safety:
MCF
Lease Use:
MCF
Conservation:
MCF
Waste:
MCF
Reviewed by:
COMMISSIONER
Comm. lComm.
Reinjected vol does not include volumes of PBU Fuel Gas reflected on line 17. Transferred From = PBU 0 mcf fuel gas. Line 18 Transferred to is volume transferred to
CPF2. Line 6 is gas sold to KTC.
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Revision? Date of Revision:
Title: Analyst, Production &Revenue Accounting
❑
Authorized Name and Digital Signature with date: (���`/1 ^17��_����
DoeuSigned by: Contact Phone: Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
------- Contact Email: lau rie. beaverslWCop. COM 60°F. Authority 20 AAC 25.235.
Submit in PDF format to
Form10-422 Revised10/2021 20AAC25.235 aogcc.reporting@alaska.gov
1013112025
CONSERVATION ORDER NO. 219
GAS FLARING OR VENTING INCIDENTS
CPF #1
October-2025
VOLUME
DATE TIME MSCF DESCRIPTION OF FLARING EVENT
FLARING OR VENTING EVENTS GREATER THAN 1 HOUR
TOTAL OVER 1 HOUR
Planned > 1 Hour
PLANNED EVENTS LESS THAN 1 HOUR
Flare or Vent Volumes
Greaterthan 1 hour 0
Less than 1 hour 1,164
Continuous Assist 35,461
Pilot and Purge 18,681
TOTAL FLARED/VENTED 55,307
PLANNED
ACTION TAKEN TO MINIMIZE
UNPLANNED VOLUME