Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAbout176-033Memorandum State of Alaska Oil and Gas Conservation Commission Re.' Cancelled or Expired Permit Action EXAMPLE: Point Mclntyre P2-36AXX API# 029-22801-95 This memo will remain at the from of the subject well file. Our adopted conventions for assigning APl numbers, permit numbers and well names did not specifically address expired or cancelled permits. This omission has caused some inconsistencies in the treatment of these kinds of applications for permit to ddil. Operators have asked us to adopt formal procedures for this class of permit application in order to prevent future database disparities. If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain unchanged. The AP! number and in some instances the well name reflect the number of preexisting reddlls and or muitilaterals in a well. In order to prevent confusing a cancelled or expired permit with an active well or multilateral these case sensitive well identifiers will be changed for expired and cancelled applications for permits to ddll. The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95. The well name for a cancelled or expired permit is modified with an appended xx. These procedures are an addendum to the APl numbering methods described in AOGCC staff memorandum "Multi-lateral (welibore segment) Ddlling Permit Procedures, revised December 29, 1995. AOGCC database has been changed to reflect these changes to this permit. e McMains ' ~ Statistical Technician ~rch 15, 1976 Trading Bay Unit State G-10 Rd. Union Oil Company of California State Permit No. 76-33 )~obert T. Anderson District Land Mana~r Union Oil Company of California P. O. Box 6247 FLnchorage, Alaska 99502 Dear Sir: Enclosed is the approved application for permit to drill the above referenced welt at a location in Section 31, Township 9N, Range 13W, S.M. Well samples, core chips anda mud log are not required. A directional survey is required. Pollution of any waters of the State is prohibited by AS 46, Chapter 03, Article 7 and the regulations prolmulgated thereunder (Title 18, Alaska Administrative Code, Chapter 70} and by the Federal ~Iater Pollution Control Act, as amended. Prior to commencin~ operations you may be contacted by a representative of the Department of Environmental Conservation. Pursuant to AS 38.40, Local Hire. Under State Leases, the Alaska Department of Labor is being~ notified of the issuance of this permit to drill. To aid u~ in schedulino field work, we would appreciate your notifyin~ this office within 48 hours~after the. well is spudded. We would also ltke"'to be notified so that a representative of the Division may be present to witness testing of blowout preventer equipment before surface casing shoe is drilled. Ro~rt T. Anderson -2- March 15, 1976 In the event of suspension or abandonment please give this office adequate advance notification so that we may have a witness present. Very truly yours, O. K. Gi lbreth, ar .... Chairman Alaska Oil and Gas Conservation Comnittee Enclosure CC: Department of Fish and Game, Habitat Section w/o encl. Department of Envtronnental Conservation w/o encl. Department of Labor, Supervisor, Labor Law Compliance Division w/o encl. Form tO REV. I--I--71 STATE OF ALASKA OIL AND GAS CONSERVATION COMMITTEE' SU'F1MIT IN 'rRIt: (Other instruction_ reverse side) PERMIT TO DRILL OR DEEPEN API# 50-133-20094-01 5. 6, [~,~SE D~i~;IGNATION AI~D S]~LLAL NO. ADL-17594 8. UNIT FARM O}{ LEASE N~NIE Trading Bay Unit 9 WELL NO. State G-10 Rd. (14-29) Ii&. TYPi~ OF WOI~K DRILL ~ (Redrill) DEEPEN b. TYPg 0F W~LL Wtr. Inj. 2 NAME OF ©PE2q~TOR UNION OIL COMPANY OF CALIFORNIA 3. ADDRE'S~ C~ OP~TOR ZONg P. O. Box 6247, Anchorage, Alaska 99502 4. LOCATION .Q~ %VEI~L . S~ At surfaceL, oncluctor 22, Leg 4: 1829'N & 1483'W from corner. Section 29: T9N, R13W, S. M. ^t ~.:o~e~ ~. ~ Hemlock Oil Pool ~ approximately 10,720'MD & · 9575'VD. Distanc~ out 4600' ~ S55°W. 13. DISTANCE IN ~IILES AND DIRECTION FROM NEAREST TOWN OR POST OFFICE' Approximately 22 air miles north of Ken~_i~~ Alaska 14. BOND INFORMATION: United Pacific Insurance Co. B-553~2 15. DISTANCE FROM PROPOSED' [18. NO, OF ACR~ IN L~ASE ~oc~o~ ~o ~.~s~ ~o~z~ on ~s~ umw. ~. 4, ~80 ' 5,120 (A13o to nearest drig, unit, if any) 18. DISTANCE FROM PROPOSED LOCA~ON* ~. PRO~OS~ D~ TO NEAREST WELL DRILLING, COMPLeTe, OR APPLIED FOR, ~,5oo' I 11 · ,640'TMD 10,240'T\ 21. ELEVATIONS (Show whether DF, IRT, C-R, etc.) ~9'RT above MSL PROPOSED CASING AND CEMENTING PROGRAM 10. FIELD AND POOL, OR WILDCAT McArthur River Field-Hemlock SEC., T., R.. M., CBOTTOM HOLE OBJECTIVE} Section 31: T9N, R13W, S. M ~-o~ $100,000 17. NO. ACRES ASSIGNED TO THiS WELL 80 ~0. I~OTARY OR CABLE TOOLS 'D Rotary 22. APPROX. DATE WORK WILL START* May 15, 1976 _ SlZE O_~H.OLE , :SIZE OF CASING ..... W~.I?HT ]PER IrOO~ 1_ ~RADE $~"TING D~ quantity of cement 22" ,, !6" 75~ J-55 "',643", ......... Preyi°h'~tf ..... set W/1000 iX cmt '~/? 18" 13,,,3/8" .... 61~ J:55 3120' ~reviousl%.set w/900, sx + 1600 ............... additives. . ............... i~ 1/4''i 9 5/8" '40;~43.5f47~. _ N80LPll0_ . 10.257'. ...... '{Previou~iv, Set w/.1500, sx w/ a, ddit .... ~'5~8'"'_~::in~,,.510,0'-5~140' (~st. KOP ~ 510{"~ ............. ladditiv 8 1/2" 7" 29# N-80 4800'-11,640' -.. Plan of Procedure enclosed. w / :ives IN ABOV~E SPACE DE~C'PABE I=~OPOSE~ PROGRAM: Ii ~I is to dee~n give ~ on present p~uctive zone ~d pro~ new preclusive zone. ~~l is ~ drill or O~n dwe~[onally, give ~rtment ~' on s~bsu~ace ~t~ ~d meas.~d ~d ve~ical dept. Give blo~ut P~e~eBter- p~g~am. 24, I hereby cer'ttfy that thj~ore~oing Is True an~ Co~t $!GNL_~~.~.f~._~.~..~,,---,~i,~..~,r~/ March 3, 1976 SAMPL~ AND CORE CHIPS R~UI~ } MilD LdO m~mN~L su~wY am~ a.~.n mc~ CO~ ~ v~ D NO _ _ _ ~r~Dist. Land Mgr. 50-133-20094-01 P'm~ZrNO .7~2q -- *z ~ A-PPP. OVALDA%I~: : Marrh lB ]976 ~ ':~'~Z~2~~~ Chairman ~p~om ~~.~-~~-<~ '7~~ =~ .............. ~xx March 15, 1976 TBUS O-10 Rd. (14-29) PERMIT TO DRILL -2- Ma. vch 3, ]976 PLAN OF P!4OCEDURE: 1. Skid rig #55 over well TBUS G-10 & RU. 2. Kil]. well w/ gel-polymer mud. Remove x-mas tree. Install & test BOPE. · 3. Plxll. & laY dwn. 3 1/2" dual tbg, strings & accessories. 4. Abandon Hemlock Injection intervals from 10,336'-10,963' Abandon 7" liner lap @ 10,018' 5. Mill window in 9 5/8" csg. from +5100 to +5140' Underream window to 15" & lay cmt. plug. 6. Run DD & kick off welt @ +5107' Drill 8 1/2" directional hole to 1],640'+TMD, 7. Log well as required. 8. Run 7" 29# N-80 liner from +4800' to +11,640? & cmt. '9. Complete well as a dual Hemlock injector as determined from Acidize the }temlock Zone i.f required. ESTIMATED OPERATING TIME- Abandon present wellborc & ~"ecl~'il]. time. Complet [,-)n Ti m e TOTAL ESTIMATED TIME Forty-Two (42) Days Fifty-Seven (57) Days Interval 4800'-1] , 640' (10,240'TVD) 6840' 7" LINER. DESIGN 29# N-80 Buttress 198,360 Acc. Wi:. l. 98 , 360 3.4 1.37 .o o · ,o VE/~ T ' . · ' ,BUBBSE. T~/.'K OR hO.::£ /,NDE D£G,qSSER L.P o. ,o · __f L. P I//~LV£T ~ · · · · o · . · · / Prop Y/Hemlock o ' / TMD I0 /'20 ' Vr 9 575' G-lO (41x-$~' Prop.B H L. / TMD I 1,640' / TV O 10,240' ( 0-11 G 9 "-. JG - h .N - MAC4 A THO~i ' / UN ION O'L COMPANY OF CA IFORNIA ALASKA ~STPICT WELL LOCATION MAP UN'ON OIL CO OPERATOR I TRADING BAY STATE UN IT--- (5- I0 RD I ( 4~ x - ~' DATE: Jon. J S C A L E I": 2 0 0 EI:r'%71 CHECK LIST FOR NEW WELL PERMITS Company ~/,~iO~ Yes No Remarks 1. Is the.permit fee attached ...................... ~ Lease & Well No. 2. Is well to be located in a defined pool ............... ~ 3. Is a registered survey plat attached ................ 4. Is well located proper distance from property line ........ /~K 5. Is well located proper distance from other wells ........... ~ 6. Is sufficient undedicated acreage'available in this pool ...... 7. Is well to be deviated ........................ ~/~J~ 8. Is operator the only affected party ................. ~ 9. Can permit be approved before ten-day wait ............. ~<~ 10. Does operator have a bond in force ................ II. Is a conservation order needed ................... 12. Is administrative approval needed .................. 13. Is conductor string provided .............. 14. Is enough cement used to circulate on conductor and surface ..... 15. Will cement tie in surface and intermediate or production strings $. Will cement cover all known productive horizonS ........... 17. Will surface casing protect fresh water zones ............ 18 Will all casing give adequate safety in collapse tension & burst 19. Does BOPE have sufficient pressure rating ............... Additional Requirements' Approval Recommended' Geol oQy~\ Engi neeri nq' TRM ~ HWK ~/~ OKG ~I HHH JAL ~i~ .... LCS~ ~,/; JCM Revised 1/15/75