Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAbout179-101Memorandum To: Re: State of Alaska Cancelled or Expired Permit Action EXAMPLE: Point Mclntyre P2-36AXX AP1 # 029-22801-95 Oil and Gas Conservation Commission This memo will remain at the front of the subject well file. Our adopted conventions for assigning APl numbers, Permit numbers and well names did not specifically address expired or cancelled permits. This omission has caused some inconsistencies in the treatment of these kinds of applications for permit to ddil. Operators have asked us to adopt formal procedures for this class of permit application in order to prevent future database disparities. If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain unchanged. The APl number and in some instances the well name reflect the number of preexisting reddlls and or multilaterals in a well. In order to prevent confusing a cancelled or expired permit with an active well or multilateral these case sensitive well identifiers will be changed for expired and cancelled applications for permits to ddll. The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95. The well name for a cancelled or expired permit is modified with an appended xx. These procedures are an addendum to the APl numbering methods described in AOGCC staff memorandum "Multi-lateral (wellbore segment) Ddlling Permit Procedures, revised December 29, 1995. AOGCC database has been changed to reflect these changes to this permit. Statistical Technician November 30, 1979 Res West Sak 25602 Well No. 18 Atlantic Richfield Company Per. it No. 79-101 Sur. Loc.~ 1700t FNL, 900t FWL, ( Proposed ) · Bottomhole Loc. ~ same as above Mr. P. A. VanDu'en District Drilling Engineer Atlantic Richfield cOmpany Anchorage, Alaska 995: Dear Mr. VanDusen~ Enclosed is the above referenced Well samp tional the di~iti for dipmeter .cation for to drill the \ and a m~ lo~ required. A direc- If 1able, a tape containing on logs shall be submitted :imental , velocity surveys and Many 16. 870 a Alask of .n Alaska and .r drainage systems have been important the spawning or migration of sh. in these areas are subject to AS ations promulgated thereunder (Title 5, Code). Prior to commencing operations by the Habitat Coorflinator~s office, and Game. apter Fedel any waters of the State is prohibited by AS 46, Article 7 and the regulations promulgated thereunder , Alaska Administrative Code, Chapter 70) and by the Water Pollution Control Act, as amended. Prior to Mr. P. A. VanDusen West Sak 25602 Well No. 18 -2- November 30, 1979 commencing operations you may be contacted by a representative of the Department of Environmental Conservation. Pursuant to AS 38.40, Local Hire Under State Leases, the Alaska Department of Labor is being notified of the issuance of this permit to drill. To aid us in scheduling field work, we would appreciate your notifying this office within 48 hours .after the well is spudded. We would also like to be notified so that a repre- -.'sentative of the commission may be present to witness testing of blowout preventer equipment before surface casing shoe is drilled. In the event of suspension or abandonment, please, give this office adequate advance notification so that we may have a witness present. Very truly yours, ~arry~ W. Kug~er Commissioner Alaska O31 & Gas Conservation Commission ~'nclosure cc~ Department of Fish & Game, ~abitat Section w/o eno1. Department of Environmental Conservation w/o/enc1. Department of Labo.r~ Supervisor, Labor Law Compliance Division w/o eno1. ARCO Oil and Ga~**~mpany North Alas~ District Post Office Box 360 Anchorage, Alaska 99510 Telephone 907 277 5637 November 28, 1979 Mr. Hoyle Hamilton State of Alaska Department of Natural Resources Division of Oil and Gas 3001 Porcupine Drive Anchorage, AK 99501 Subject: West Sak 25602 No. 18 Dear Sir: Enclosed herewith, is our Application for Permit to Drill West Sak 25602 No. 18, a sketch of the surface diverter system, and a $100.00 filing fee. An as-built survey will be sent as soon as it is available. -Very truly yours, P. A. VanDusen District Drilling Engineer PAV:mb Enclosure ARCO Oil and Gas Company is a Division of AtlanticRichfieldCompany Form 10-401' REV. 1-1-71 STATE OF ALASKA OIL AND GAS CONSERVATION COMMITTEE PERMIT TO DRILL OR DEEPEN OTHER la. TYPE OF WORK DRILL b. TYPE OF WELL OIL GAS WELL [] WELL SUBMIT IN T .~ATE (Other instructions on reverse side) 2. NAME OF OPERATOR Atlantic Richfield Co. DEEPEN ['-'] 3. ADDRESS OF OPERATOR P.O. Box 360, Anchorage, Alaska 99510 4. LOCATION OF WELL SINGLE ZONE MULTIPLE At surface 1700'FNL, 900'FWL, Sec. 13, T10N, R7E, DM (Proposed) At proposed prod. zone 13.' DISTANCE IN MILES AND DIREL~ION FROM NEAREST TOWN OR POST OFFICE* 18. DISTANCE FROM PROPOSED LOCATION TO NEAREST WELL DRILLING, COMPLETED, OR APPLIED FOR, FT. 37,960 21. ELEVATIONS (Show whether DF, RT, CR, etc.) Approx 85' GL (Not surveyed) 23. PROPOSED CASING AND CEMENTING PROGRAM ADL 25602 ?. IF INI)IAN, ALLOTII~E OR TRIBE NAME 8. UNIT FARM OR LEASE NAME West Sak 25602 9. WELL NO. 18 10. FIELD AND POOL, OR WILDCAT Kuparuk Ri ver 11. SEC., T., R., M., (BOTTOM HOLE OBJECTIVE) Sec. 13, T10N, R7E, UM 12. 43 miles west of Deadhorse, Alaska 14. BOND INFORMATION: r~E Statewidm~etyand/orNo. 0ii & Gas Bond #8011-38-40 (Federal In ~CoOun;: 15. DISTANCE FROM'PROPOSED * [ 16. No. OF ACRES IN LEASE LOCATION TO NEAREST · PROPERTY OR LEASE LINE, FT. 900' 2560 (Also to nearest drig, unit, if any) 19. PROPOSED DEPTH 7000' $1 '00: 000 17. NO.ACRES ASSIGNED TO THIS WELL 160 20. ROTARY OR CABLE TOOLS Rotary 22. APPROX. DATE WORK WILL START Feb 80' SIZE OF HOLE SIZE OF CASING : WEIGHT PER FOOT , GRADE , SETTING DEFrH ' Quantity of'cement ': 32" 16" 65. H-40 85"GL' Cmt'to surf ' approx~350"ft3 13-3/4" 10--~/4" a~ .~ K-55 e?nn, rm~r fn :,,~ . ann~n¥ ~nnn ......... · . ~, -rr ........ , · 9-77~" 7" 26 K-55 7-rlr¥1' Cmt tn st, w* - anp~ny'l?Rn f, ' i,~ -''1 Arctic Pak from 2000 to surf The Atlant'ic Richfield C'o . propoSes to drill a Kuparuk River exploratory well 'co approximatel3 7000' Selected intervals will be logged, cored, and tested. A 20" x 2000 psi annular divert( will ~e installed on 16" conductor while drilling surface hole as" per Division of 0ii and Gas requirements. A 13-5/8" x 5000 psi BOP stack consisting of one annular preventer, one blind "' preventer and two pipe ram preventers will be installed and tested on the wellhead for the remainder of the drilling and testing. The BOP stack will be tested to 3000 psi weekly during the course of the well. The well will be completed with 3-1/2" N~80 tubi-fig. Non-freezing flui will be left in any uncemented annuli thru the permafrost area. Permafrost is estimated to be not below 1650 ft. A certified survey plat will be submitted before spudding. IN ABOVE SPACE DESCRIBE PROPOSED PROGRAM: If proposal is to deepen give data on present productive zone and proposed new productive zone. If proposal is to drill or deepen directionally, give pertinent data on subsurface locations and measured and true vertical depths. Give blowout preventer program. Si24~ ,e~,e~tTat thFf~ect DATE /t/~g'e,,~er Z,~ /¢~q TITLE Dist. Drlg. Engr. (This space for State office use) CONDITIONS OF APPROVAL, IF ANY: OTHER REQUIREMENTS: ISAMPLES AND CORE CHIPS REQUIRED ~S [] NO DIRECTIONAL SURVEY REQUIRED [] YES ~NO MUD LOG ~[YES [] NO A.P.I. NUMERICAL CODE ,S'b-/03- ~.~,~/.~'~ PERMITNO.. 7 ~-10 / APPROVAL DATE November 30, 1979 APPOVED BY ~--~'~-~-~ /~'x } ~.,.~/~ TITLEcCEIIlis siGner DATE 11-30-79 _',. / ~-' -/V'-' *See Instruction On Reverse Side SURF ACE DI ' '~' b ~ E.,TE., SYSTEi'.I · · t ': .o". .... -. '.:" .' . " .-. '- .. ' ~': ......~ ?: ~ - . ': ....."~.~._ ,'. "' '"'".' "='_:::-"'";" ' ...;. --....".. ....;:::. · . .. .-. · 2. 3. 16'""x' 20" X-over 20" 2090 psi drilling spool 20" 2000 psi annular preventer 6" butter, fly valves CI4J~CK LIST FOR NEW ~ELL PERMITS Ca~pany Yes [ the permit fee ttached · ~ . Is a .......................................... ~.. Is v,~ll to be located in a defined pool ............................. _ ~"_~/_ ,/ 3~. Is a registered sxkrvey plat attached ................................ ~ / ~. Is %~11 located proper distance frc~ property line ............. , .... ~_~ 5. Is well located proper distance frcm other wells ....../qp4, / 6. Is sufficient underdicated acreage available in this pool ...... ' .....~. / 7. Is well to be deviated .............................................. e 8. Is operator the only affected party ............................... '-- / Can permit be approved before ten-day ~ait ............ ' ............. Does ooerator have a bond in force ............. , .................... / I.. Is a conservation order needed ...................................... No Remarks 2. Is administrative approval needed .................................... 3. Is conductor string provided ........................................ ~__ ~4. Is enough cement used to circulate on conductor and surface ......... ~ .5. Will cement tie in surface and intermediate or production strings ... ~ Lease & Well No. ~j~ Jv/~- ~ ~ Item~ Approve Date (1) Fee <7~')--. ~- z~- ? (2) Loc. (3) Admin. ~~__ //-%9,-?/4 .6. Will cement cover all known productive horizons ..................... ~ .7. ¥7ill surface casing protect fresh water zones ....................... ~ .8. Will all casing give adequate safety in collapse, tension and barst.. ~_ L9. DOes BOPE have sufficient pressure rating - Test to ~% psig .. ~ Approval Reccmme~: (5) ~%dditional Requirements: Geology: dAL Engin ~ering: rev: 06/21/7