Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAbout179-101Memorandum
To:
Re:
State of Alaska
Cancelled or Expired Permit Action
EXAMPLE: Point Mclntyre P2-36AXX AP1 # 029-22801-95
Oil and Gas Conservation Commission
This memo will remain at the front of the subject well file.
Our adopted conventions for assigning APl numbers, Permit numbers and well names did not
specifically address expired or cancelled permits. This omission has caused some inconsistencies in
the treatment of these kinds of applications for permit to ddil. Operators have asked us to adopt
formal procedures for this class of permit application in order to prevent future database disparities.
If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain
unchanged. The APl number and in some instances the well name reflect the number of preexisting
reddlls and or multilaterals in a well. In order to prevent confusing a cancelled or expired permit with
an active well or multilateral these case sensitive well identifiers will be changed for expired and
cancelled applications for permits to ddll.
The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95.
The well name for a cancelled or expired permit is modified with an appended xx.
These procedures are an addendum to the APl numbering methods described in AOGCC staff
memorandum "Multi-lateral (wellbore segment) Ddlling Permit Procedures, revised December 29,
1995.
AOGCC database has been changed to reflect these changes to this permit.
Statistical Technician
November 30, 1979
Res West Sak 25602 Well No. 18
Atlantic Richfield Company
Per. it No. 79-101
Sur. Loc.~ 1700t FNL, 900t FWL,
( Proposed )
· Bottomhole Loc. ~ same as above
Mr. P. A. VanDu'en
District Drilling Engineer
Atlantic Richfield cOmpany
Anchorage, Alaska 995:
Dear Mr. VanDusen~
Enclosed is the
above referenced
Well samp
tional
the di~iti
for
dipmeter
.cation for
to drill the
\
and a m~ lo~ required. A direc-
If 1able, a tape containing
on logs shall be submitted
:imental , velocity surveys and
Many
16. 870 a
Alask
of
.n Alaska and .r drainage systems have been
important the spawning or migration of
sh. in these areas are subject to AS
ations promulgated thereunder (Title 5,
Code). Prior to commencing operations
by the Habitat Coorflinator~s office,
and Game.
apter
Fedel
any waters of the State is prohibited by AS 46,
Article 7 and the regulations promulgated thereunder
, Alaska Administrative Code, Chapter 70) and by the
Water Pollution Control Act, as amended. Prior to
Mr. P. A. VanDusen
West Sak 25602 Well No. 18
-2-
November 30, 1979
commencing operations you may be contacted by a representative
of the Department of Environmental Conservation.
Pursuant to AS 38.40, Local Hire Under State Leases, the Alaska
Department of Labor is being notified of the issuance of this
permit to drill.
To aid us in scheduling field work, we would appreciate your
notifying this office within 48 hours .after the well is
spudded. We would also like to be notified so that a repre-
-.'sentative of the commission may be present to witness testing
of blowout preventer equipment before surface casing shoe is
drilled.
In the event of suspension or abandonment, please, give this
office adequate advance notification so that we may have a
witness present.
Very truly yours,
~arry~ W. Kug~er
Commissioner
Alaska O31 & Gas Conservation Commission
~'nclosure
cc~ Department of Fish & Game, ~abitat Section w/o eno1.
Department of Environmental Conservation w/o/enc1.
Department of Labo.r~ Supervisor, Labor Law Compliance
Division w/o eno1.
ARCO Oil and Ga~**~mpany
North Alas~ District
Post Office Box 360
Anchorage, Alaska 99510
Telephone 907 277 5637
November 28, 1979
Mr. Hoyle Hamilton
State of Alaska
Department of Natural Resources
Division of Oil and Gas
3001 Porcupine Drive
Anchorage, AK 99501
Subject: West Sak 25602 No. 18
Dear Sir:
Enclosed herewith, is our Application for Permit to Drill West Sak 25602
No. 18, a sketch of the surface diverter system, and a $100.00 filing
fee. An as-built survey will be sent as soon as it is available.
-Very truly yours,
P. A. VanDusen
District Drilling Engineer
PAV:mb
Enclosure
ARCO Oil and Gas Company is a Division of AtlanticRichfieldCompany
Form 10-401'
REV. 1-1-71
STATE OF ALASKA
OIL AND GAS CONSERVATION COMMITTEE
PERMIT TO DRILL OR DEEPEN
OTHER
la. TYPE OF WORK
DRILL
b. TYPE OF WELL
OIL GAS
WELL [] WELL
SUBMIT IN T .~ATE
(Other instructions on
reverse side)
2. NAME OF OPERATOR
Atlantic Richfield Co.
DEEPEN ['-']
3. ADDRESS OF OPERATOR
P.O. Box 360, Anchorage, Alaska 99510
4. LOCATION OF WELL
SINGLE
ZONE
MULTIPLE
At surface
1700'FNL, 900'FWL, Sec. 13, T10N, R7E, DM (Proposed)
At proposed prod. zone
13.' DISTANCE IN MILES AND DIREL~ION FROM NEAREST TOWN OR POST OFFICE*
18. DISTANCE FROM PROPOSED LOCATION
TO NEAREST WELL DRILLING, COMPLETED,
OR APPLIED FOR, FT.
37,960
21. ELEVATIONS (Show whether DF, RT, CR, etc.)
Approx 85' GL (Not surveyed)
23. PROPOSED CASING AND CEMENTING PROGRAM
ADL 25602
?. IF INI)IAN, ALLOTII~E OR TRIBE NAME
8. UNIT FARM OR LEASE NAME
West Sak 25602
9. WELL NO.
18
10. FIELD AND POOL, OR WILDCAT
Kuparuk Ri ver
11. SEC., T., R., M., (BOTTOM
HOLE OBJECTIVE)
Sec. 13, T10N, R7E, UM
12.
43 miles west of Deadhorse, Alaska
14. BOND INFORMATION:
r~E Statewidm~etyand/orNo. 0ii & Gas Bond #8011-38-40 (Federal In ~CoOun;:
15. DISTANCE FROM'PROPOSED * [ 16. No. OF ACRES IN LEASE
LOCATION TO NEAREST
· PROPERTY OR LEASE LINE, FT. 900' 2560
(Also to nearest drig, unit, if any)
19. PROPOSED DEPTH
7000'
$1 '00: 000
17. NO.ACRES ASSIGNED
TO THIS WELL
160
20. ROTARY OR CABLE TOOLS
Rotary
22. APPROX. DATE WORK WILL START
Feb 80'
SIZE OF HOLE SIZE OF CASING : WEIGHT PER FOOT , GRADE , SETTING DEFrH ' Quantity of'cement ':
32" 16" 65. H-40 85"GL' Cmt'to surf ' approx~350"ft3
13-3/4" 10--~/4" a~ .~ K-55 e?nn, rm~r fn :,,~ . ann~n¥ ~nnn
......... · . ~, -rr ........ , ·
9-77~" 7" 26 K-55 7-rlr¥1' Cmt tn st, w* - anp~ny'l?Rn f,
' i,~ -''1
Arctic Pak from 2000 to surf
The Atlant'ic Richfield C'o . propoSes to drill a Kuparuk River exploratory well 'co approximatel3
7000' Selected intervals will be logged, cored, and tested. A 20" x 2000 psi annular divert(
will ~e installed on 16" conductor while drilling surface hole as" per Division of 0ii and Gas
requirements. A 13-5/8" x 5000 psi BOP stack consisting of one annular preventer, one blind "'
preventer and two pipe ram preventers will be installed and tested on the wellhead for the
remainder of the drilling and testing. The BOP stack will be tested to 3000 psi weekly during
the course of the well. The well will be completed with 3-1/2" N~80 tubi-fig. Non-freezing flui
will be left in any uncemented annuli thru the permafrost area. Permafrost is estimated to be
not below 1650 ft. A certified survey plat will be submitted before spudding.
IN ABOVE SPACE DESCRIBE PROPOSED PROGRAM: If proposal is to deepen give data on present productive zone and proposed
new productive zone. If proposal is to drill or deepen directionally, give pertinent data on subsurface locations and measured and true
vertical depths. Give blowout preventer program.
Si24~ ,e~,e~tTat thFf~ect
DATE /t/~g'e,,~er Z,~ /¢~q
TITLE Dist. Drlg. Engr.
(This space for State office use) CONDITIONS OF APPROVAL, IF ANY:
OTHER REQUIREMENTS:
ISAMPLES AND CORE CHIPS REQUIRED
~S [] NO
DIRECTIONAL SURVEY REQUIRED
[] YES ~NO
MUD LOG
~[YES
[] NO
A.P.I. NUMERICAL CODE
,S'b-/03- ~.~,~/.~'~
PERMITNO.. 7 ~-10 / APPROVAL DATE November 30, 1979
APPOVED BY ~--~'~-~-~ /~'x } ~.,.~/~ TITLEcCEIIlis siGner DATE 11-30-79
_',. / ~-' -/V'-' *See Instruction On Reverse Side
SURF ACE DI ' '~' b
~ E.,TE., SYSTEi'.I
·
· t ': .o". .... -. '.:" .' . " .-. '- .. ' ~': ......~ ?: ~ -
.
': ....."~.~._ ,'. "' '"'".' "='_:::-"'";" ' ...;. --....".. ....;:::.
· .
..
.-.
·
2.
3.
16'""x' 20" X-over
20" 2090 psi drilling spool
20" 2000 psi annular preventer
6" butter, fly valves
CI4J~CK LIST FOR NEW ~ELL PERMITS
Ca~pany
Yes
[ the permit fee ttached · ~
. Is a ..........................................
~.. Is v,~ll to be located in a defined pool ............................. _ ~"_~/_
,/
3~. Is a registered sxkrvey plat attached ................................ ~
/
~. Is %~11 located proper distance frc~ property line ............. , .... ~_~
5. Is well located proper distance frcm other wells ....../qp4,
/
6. Is sufficient underdicated acreage available in this pool ...... ' .....~.
/
7. Is well to be deviated ..............................................
e
8. Is operator the only affected party ............................... '--
/
Can permit be approved before ten-day ~ait ............ ' .............
Does ooerator have a bond in force ............. , ....................
/
I.. Is a conservation order needed ......................................
No Remarks
2. Is administrative approval needed ....................................
3. Is conductor string provided ........................................ ~__
~4. Is enough cement used to circulate on conductor and surface ......... ~
.5. Will cement tie in surface and intermediate or production strings ... ~
Lease & Well No. ~j~ Jv/~- ~ ~
Item~ Approve Date
(1) Fee <7~')--. ~- z~-
?
(2) Loc.
(3) Admin. ~~__ //-%9,-?/4
.6. Will cement cover all known productive horizons ..................... ~
.7. ¥7ill surface casing protect fresh water zones ....................... ~
.8. Will all casing give adequate safety in collapse, tension and barst.. ~_
L9. DOes BOPE have sufficient pressure rating - Test to ~% psig .. ~
Approval Reccmme~:
(5)
~%dditional Requirements:
Geology:
dAL
Engin ~ering:
rev: 06/21/7