Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAbout170-038Memorandum State of Alaska Oil and Gas Conservation Commission Cancelled or Expired Permit Action EXAMPLE: Point McIntyre P2-36AXX API# 029-22801-95 This memo will remain at the front of the subject well file. Our adopted conventions for assigning APl numbers, permit numbers and well names did not specifically address expired or cancelled permits. This omission has caused some inconsistencies in the treatment of these kinds of applications for permit to ddll. Operators have asked us to adopt formal procedures for this class of permit application in order to prevent future database disparities. If a permit expires or is cancelled by an operator, the permit number of the subject permit will remain unchanged. The APl number and in some instances the well name reflect the number of preexisting redrills and or multilaterals in a well. In order to prevent confusing a cancelled or expired permit with an active well or multilateral these case sensitive well identifiers will be changed for expired and cancelled applications for permits to ddll. The APl number for this cancelled or expired permit is modified so the eleven and twelfth digits is 95. The well name for a cancelled or expired permit is modified with an appended xx. These procedures are an addendum to the APl numbering methods described in AOGCC staff memorandum "Multi-lateral (wellbore segment) Drilling Permit Procedures, revised December 29, 1995. AOGCC database has been changed to reflect these changes to this permit. McMains ' t Statistical Technician ea~ l:Mpa~t~en~ of~ ~ ami ~ erie earl ~cae~c of Labor v/o enr. t. l~orm P--1 ' ~ SUBMIT IN TRIPL~ (O~her instructions reverse side) STATE OF ALASKA OIL AND C-AS CONSERVATION ,COMMITTEE APPLICATION FOR PERMIT TO DRILL~ DEEPEN~ OR PLUG BACK DRILL [] DEEPEN l---I PLUG BACK OIL ~ GA8 [~] 8INGLE ~ MUI,TIPI,EF_] WELl, WELL OTHI[R ZON~ ZONE 2. NAME OF OPERATOR * Union Oil Company of California 3, ADDRESS O~ OPF-,RATOR 2805 Denali Street, Anchorage, Alaska 4. LOCATION OF WELL At'sur,ace 759.21 FSL, 1218.4' FWL Sec. 6, TSN, R13W, S.M. Cond. 5, Leg A-1 ^tP"°~°sedpr°d'z°"e Top of "G" Zone - 750' FSL, 450' FWL Sec. T8N, R13W, SH .-. DISTANCE IN MILES AND DIRECT!ON FAOM NEAREST TOWN OR POST OFFICE* 21 miles NW of Kenai, Alaska 6. L,E~Sw- DIESIGNATION AND SI/RIAL NO~ ADL-1 8729 FILE . . ~ ~. IF INDIAN, ALJ.,OTTEE OR TRIBE NA2~E 8. UNIT, FARM OR LEASE NAME Trading Bay Unit 9. WELL NO. D-33 (14X-5) 10. FIELD AND POOL. OR WILDCAT McArthur River Middle Kenai iiGii SEC.. T., R., M., (BOTTOM HOLE OBJECTIVE) Sec. 5, T8N, R13W, SM 14. BOND INFORMATION: TYPE Statewide surety and/or No. UnJted Pacific Insurance Co B-55502 15. DISTANCE FROM PROPOSED* I18. NO. OF ACRF_~ IN LEASE LOCATION TO NEAREST ' PROPERTY OR LEASE LINE, FT. 4,530' ] 3085 (Al~o to nearest drig, unit, if any) 18. DISTANCE FROM PROPOSED LOCA'I'ION' i 19. PR'6POS~D DEPTH TO NEAREST WELL DRILLING, COMPLETED, I OR APPLIED FOR, FT. 1,000I I 9,3501 VD, 10 ,603' MD A~o,,-t $100,000.00 17. NO. ACRES ASSIGNED TO THiS WELL 160 20. ROTARY OR CABLE TOOLS Rotary 21. ELEVATIONS (Show whether DF, RTl CH. etc.~ 22. APPROX. DATE WORK W]I,I, ~TART* 106.00 R.T. Mean Sea Level August 6, 1970 23. PROPOSED CASING AND CEMENTING i°ROGRAM ,,,, SIZE OF HOLE sIZE OF CASING~ WEIGHT PER FOO~ GRADt~ ' SET~G DEPTH Q[;iNTIT! OF ~7~" 13e3/8" 61~ , 'K'-55 2,500 1800 Sacks 12~" 9-5/8" '40~ N-80 4,20,0 12~" ~-5/8" ~ ~,5~ N-80 6,400 2~00 sacks 12~~l ;.}~- ~/8~! ~7~ N-80~ ,7 ,~00 .... 12~" 9-5/8,, ~7~ ,S-95 10,6~0 Blowout Preventer Program: Install 20" 2000// hydril atop 33" Conductor through 20" 600 Series riser. Test kill line & choke manifold with 2000 psig. Install & test 13-5/8" 500 psig Cameron Type U double gate, 5000 psig choke manifold & kill line, with 3000 psi after 13-3/8" is set. Same BOP hookup for 9-5/8" &.test with 5000 psig for complet ion operations. RE:C'E!VED *Suboperator: Marathon 0il Company - Dolly Va'rden Platform Bottom Hole Location: 743' FSL, 861' FWL Sec. 5, T8N, R13W, SM JUN IN ABOVE SPACE DESCRIBE FROPOSED PROGRAM: If propo~ml i~ to deepen or plug back, give data on presenO[hqxt/H~%O~b~tL~D GAS proposed- r~ew productive zol~e. If proposal is to drill or deepen direc~'.onally,, give pertinent data on s~bsurfaee locations true vertical depths. Give blowout preven~t~r program. 24. I her~W~if3~hat t.~..he Foregoing is True2and~/0rre~t S!O'~~~_,''~'~'~' ~----~'~:"~"' ~'.~/'~ '/" ~"'"~_ ...... DATE' ,June 25 , 1970 T,','~ Landman (This space for State office use) CONDITIONS O~ APPI~¥A~ Ir ANY: t A.P.I. ~CAL CODE 1 I D-II :. /m (~4-32) / / / UN~O N-MA RATH( DOLLY ~2 . ~G-30 D-32 ).-31 ...0 (~2X-5) (32-6) e" D-3~''' (42-6) 2-~--~--'----- 22-5) D-14 (44 -7) \ \ \ PPSS b-8 (24-8) ADL 18729 ADL 17579 ~ D-22 ,,~(~x-18) (12X-17) \ \ D-21 (24X-17) T9N R 13W · , i i G-14A r- D-lO (44 -5) RECE!VFD JUN 2~ 1970 DIVISION OF OIL AND OAS ANCHORAGE · N UNION WELL LOCATION MAP MARATHON SUB-OPERATOR TRADING BAY STATE UNIT D,~33 (14X-5) . SCALE: I"- 2000' ~ . .JUNE ~2L ,o TSN RI3W , ---o...._ _TD 11,281' ~ D-19 ~ (22-4) CHECK LIST FOR NEW WELL PERMITS . ' ~ · - .... Yes No Remarks · _ ~ , · Is well to be locate~ in a defined pool ..... . ........... kc ~ ..' Do statewide rules a~ly ..... ' ' - . ttached t. Is a registered sur~/ plat a . . .'~' - · e e · · · · · · · · · · · · ~. Is well located prmper distance from property line , . . . .- .. '. i. Is well located proper distance from other wells-. ........... i Is: sufficient~'undeClJCated acreage available'in'thiS pool . . '. . . .-. ..: ~....,:-..,:_ · . :? ,:;..','~ :~' ';:::: :; -. , ;: .. '.'. ~ ~ well to be dermal'"-" :':?;- -.- ..-.....~"-.- .... .~;......, ......... . ' P befo ), 'Can Permit be a .promed re ten-day wat ::'"' ' :':'"-~'..."'. -'- .. ' ' .-::'-i' .'"'~'-~':: :: ..... __in___f~rce"-:' ' :::~:' ' I0. Does operator have a bond . . . ...-.~..... ............ Il. Is conductor string l~vided ...... - .................. I~. Is enough cement us~l to circulate on conductor and surface- . .... 13. Will-cement tie in serface and intermediate or production strings . . . 14. Will cement cover all possible productive horizons , .- .......... /~:;~ . 15. Will surface casing cover all fresh water zones ............ 16. Will surface csg. imternal burst equal .5 psi/ft, to next string 17. Will all casing give adequate safety in collapse and tension ...... 18. Does BOPE have sufficient pressure rating ............... ~.~ Additional Requirements: Approval Recon~ended: TRM REL KLV ~ ,///~/' OKG HWK ~d~ · LCS ~---~'-.,,