Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAbout218-005p7 -D 2l 8—D 05- Loepp, Victoria T (DOA) From: Hallford, Kelsey <Kelsey.Hallford@conocophillips.com> Sent: Friday, March 23, 2018 11:11 AM To: Loepp, Victoria T (DOA) Cc: Bearden, 1 Daniel; Brunswick, Scott A Subject: RE: [EXTERNAL]KRU 11-1-103 L1, L2, L3 (PTD 218-004, 005, 006) FIT Waiver Follow Up Flag: Follow up Flag Status: Flagged Thank you. Kelsey From: Loepp, Victoria T (DOA) [mailto:victoria.loepp@alaska.gov] Sent: Friday, March 23, 2018 11:00 AM To: Hallford, Kelsey <Kelsey.Hallford@conocophillips.com> Cc: Bearden, J Daniel <J.Daniel. Bearden@ conocophillips.com>; Brunswick, Scott A <Scott.A.Brunswick@conocophillips.com> Subject: [EXTERNAL]KRU 1H-103 Ll, L2, L3 (PTD 218-004, 005, 006) FIT Waiver Kelsey, A waiver is granted to eliminate FIT/LOT testing on the next three laterals (218-004, 218-005, 218-006) on KRU 1H-103 L1-L3 laterals, and conduct the final planned FIT on the shallowest lateral (PTD 218-007) KRU 11-1-1031-4. Victoria Victoria Loepp Senior Petroleum Engineer State of Alaska Oil & Gas Conservation Commission 333 W. 7th Ave Anchorage, AK 99501 Work: (907)793-1247 Victoria Loeooriilalaska aov CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, contains information from the Alaska Oil and Gas Conservation Commission (AOGCC), State of Alaska and is for the sole use of the intended recipient(s). It may contain confidential and/or privileged information. The unauthorized review, use or disclosure of such information may violate state or federal law. If you are an unintended recipient of this e-mail, please delete it, without first saving or forwarding it, and, so that the AOGCC is aware of the mistake in sending it to you, contact Victoria Loepp at (907)793-1247 or Victoria Loeoo®alaska aov From: Hallford, Kelsey <Kelsey. Hallford(cDconocoohillios com> Sent: Friday, March 23, 2018 10:41 AM To: Loepp, Victoria T (DOA) <victoria.loeooCa alaska eov> Cc: Bearden, J Daniel <J.Daniel Bearden( a�conoconhilIips co m>; Brunswick, Scott A <Scott.A.BrunswickC�conocoohillios com> Subject: RE: [EXTERNAL]RE: PTD# 218-004, 005, 006 FIT Waiver Good morning Victoria, The TOC is assuming 40% washout at 3565' MD/ 2802' TVD. The top of pool is the base of the Ugnu Sands/Top of the N sands at 5802' MD / 3562' TVD. These are noted on the attached schematic showing as drilled formation tops, casing points, and current drilled depth. Please let me know if there is additional information you would like to see. Kelsey Hallford From: Loepp, Victoria T (DOA) [mailto:victoria.loepp@alaska.gov] Sent: Thursday, March 22, 2018 1:26 PM To: Hallford, Kelsey <Kelsey.Hallford@conocophillips.com> Cc: Bearden, J Daniel <J.Daniel.Bearden@conocophillips.com> Subject: RE: [EXTERNAL]RE: PTD# 218-004, 005, 006 FIT Waiver What is TOC assuming 30% washout? From: Loepp, Victoria T (DOA) Sent: Thursday, March 22, 2018 1:24 PM To: 'Hallford, Kelsey' <Kelsev.Hallford@conocophillips.com> Cc: Bearden, J Daniel (J. Daniel. Bearden@conocophillips.com) <J.Daniel.Bearden@conocophillips.com> Subject: RE: [EXTERNAL]RE: PTD# 218-004, 005, 006 FIT Waiver Please send current schematic and cement job pump chart. Also, identify TOC(md/tvd) and pool top. Thanx, Victoria Victoria Loepp Senior Petroleum Engineer State of Alaska Oil & Gas Conservation Commission 333 W. 7th Ave Anchorage, AK 99501 Work: (907)793-1247 Victoria. LoeooCcDalaska coy CONFIDENTIALITY NOTICE: This e-mail message, including any attachments, contains information from the Alaska Oil and Gas Conservation Commission (AOGCC), State of Alaska and is for the sole use of the intended recipient(s). It may contain confidential and/or privileged information. The unauthorized review, use or disclosure of such information may violate state or federal law. If you are an unintended recipient of this e-mail, please delete it, without first saving or forwarding it, and, so that the AOGCC is aware of the mistake in sending it to you, contact Victoria Loepp at (907)793-1247 or Victoria Loeoo@alaskayov From: Hallford, Kelsey <Kelsev.Hallford@conocophillips.com> Sent: Thursday, March 22, 20181:16 PM To: Loepp, Victoria T (DOA) <victoria.loeppCn@alaska.gov> Cc: Bearden, J Daniel <J Daniel Bearden@conocophillips com>; Brunswick, Scott A <Scott.A. Brunswick @conocophiIIi ps.com> Subject: RE: [EXTERNAL]RE: PTD# 218-004, 005, 006 FIT Waiver Sorry about that, here it is: From: Loepp, Victoria T (DOA)[mailto:victoria.loepp@alaska.gov] Sent: Thursday, March 22, 20181:15 PM To: Hallford, Kelsey <Kelsey.Hallford@conocophillips.com> Cc: Bearden, J Daniel <J.Daniel.Bearden@conocophillips.com>; Brunswick, Scott A <Scott.A.Brunswick@conocophillips.com> Subject: [EXTERNAL]RE: PTD# 218-004,005,006 FIT Waiver No attachments From: Hallford, Kelsey <Kelsey.Hallford@conocophillips.com> Sent: Thursday, March 22, 2018 12:20 PM To: Loepp, Victoria T (DOA) <victoria.loepp@alaska.gov> Cc: Bearden, J Daniel <J. Daniel. Bearden@conocophillips.com>; Brunswick, Scott A <Scott.A.Brunswick@conocoph i l lips.com> Subject: FW: PTD# 218-004, 005, 006 FIT Waiver Victoria, Approved permits to drill (218-004, 218-005, 218-006) on KRU 11-1-103 1-1-1-3 laterals require a copy of the intermediate cement job report to be submitted for an FIT waiver consideration for the middle 3 laterals of the penta-lateral; all within the West Sak sand. A FIT was conducted on the parent lateral (PTD 218-003) KRU 11-1-103 to the maximum required target of 13ppg EMW. As such, we plan to eliminate FIT/LOT testing on our next three laterals, and conduct the final planned FIT on the shallowest lateral (PTD 218-007) KRU 1H-1031-4. Attached you will find the requested 7-5/8" intermediate cement job report on KRU well 11-1-103. • Full returns throughout cement job • Casing was reciprocated • Cement plugs bumped and floats held • Casing was pressure tested to 3500 psi • 250 bbls of cement was pumped to cover 250' TVD above Ugnu C Please advise, Kelsey Hallford Senior Drilling Engineer ConocoPhillips, Alaska 1 H-103 — West Sak A2, A3, A4, B and D Sand Producer A2 Lateral Notes MDfrVD Geo Tops Casing/Cement Hole/Casing Comments MD'/ TVD Size 13-1/2" X 10-3/4" 45.5# L80 Hydril 563 Surf. Shoe 1850/1741 1677' 1771' Top of Top of Cement: 3565' MDI 2802' TVD Cement Top of cement corresponds to: 760' TVD above West Salk Pool 345' TVD above Hydrocarbons 9 7/8" 250' TVD above Ugnu C X 7-5/8" 29.7# 4145/3052 L80 -.....- . Hydri1563 Ugnu C 4442/3147 ......................... Hydrocarbons 5121/3360 5405/3447 Ugnu B ......................... Ugnu A Top of Pool: 5802' MD / 3562' TVD Top of Pool 15802/3562 N - 6837/3806 7215/3897 WestSak , 7365/3934 ......................... WestSak - 8 7557/3981 WestSak - A4 7929/4070 ........................ WestSak-A3. Int. Shoe 8112 / 4087 811 40 WestSa Currently drilling 6-'/." Hole @ 11000' MD Cement ConocoPhillips 1H-103 Intermediate Casing Cement Cement Details Deseription Cementing Start Date Cementing nd ate WNlbore Name Intermediate Casing Cement &212D189945 3+21201804:9? 14-103 " GCS.. i_4JaM1fi_t; SSEi' _ Cement Stages Stage R 1 escripaon bjeedve '.op DepO (flael jiloftoc Depm ( ) Intermediate Casing Cement Intermediate 3.585.D 8.112.: .. ._ ._ Cement casing r beitmin - ump ma"obR. imp A,; (c0" .^tp F'�a"e5" +';5 • z :. _ :.. iot - Fipe RPA lrpmj .-.. .mE T:- 0•n: 7utDiareter lint n*s- Cetaent Fluids i Additives Fluid Fluid Description _on ,Dt Ez'. E _ .. .,. .. _ .'rz -. -•Pe stip, E. Pater I 1 a -'p'sts 1 Ips,: Additives Fluid Dinicripton 11ij Additives rrC .il -ar. iaPs Page 11 Report Printed: 3/27/2018