HomeMy WebLinkAbout219-163DATA SUBMITTAL COMPLIANCE REPORTAPI No. 50-103-20811-60-00Well Name/No. COLVILLE RIV UNIT CD5-96L1Completion Status1-OILCompletion Date1/27/2020Permit to Drill2191630Operator ConocoPhillips Alaska, Inc.MD24463TVD7457Current Status1-OIL4/20/2020UICNoWell Log Information:DigitalMed/FrmtReceivedStart StopOH /CHCommentsLogMediaRunNoElectr DatasetNumberNameIntervalList of Logs Obtained:GR/ResNoNoYesMud Log Samples Directional SurveyREQUIRED INFORMATION(from Master Well Data/Logs)DATA INFORMATIONLog/DataTypeLogScaleC2/5/20202436 14140 Electronic Data Set, Filename: CPAI_CD5-96L1_Scope_Service_RM_LWD002_.las32022EDDigital DataC2/5/202014051 15207 Electronic Data Set, Filename: CPAI_CD5-96L1_Scope_Service_RM_LWD003_.las32022EDDigital DataC2/5/202015146 26635 Electronic Data Set, Filename: CPAI_CD5-96L1_Scope_Service_RM_LWD004_.las32022EDDigital DataC2/5/202013470 13880 Electronic Data Set, Filename: CPAI_CD5-96L1_Scope_Service_RM_LWD005_.las32022EDDigital DataC2/5/202013766 20654 Electronic Data Set, Filename: CPAI_CD5-96L1_Scope_Service_RM_LWD006_.las32022EDDigital DataC2/5/202020594 24462 Electronic Data Set, Filename: CPAI_CD5-96L1_Scope_Service_RM_LWD007_.las32022EDDigital DataC2/5/202067 24462 Electronic Data Set, Filename: CPAI_CD5-96L1_Scope_Service_RM_Well_Composite_.las32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD001.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD001.html32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD002.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD002.html32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD003.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD003.html32022EDDigital DataMonday, April 20, 2020AOGCCPage 1 of 4CPAI CD5-,_96L1_Scope_Service_RM_Well_Composite_.las
DATA SUBMITTAL COMPLIANCE REPORTAPI No. 50-103-20811-60-00Well Name/No. COLVILLE RIV UNIT CD5-96L1Completion Status1-OILCompletion Date1/27/2020Permit to Drill2191630Operator ConocoPhillips Alaska, Inc.MD24463TVD7457Current Status1-OIL4/20/2020UICNoC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD004.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD004.html32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD006.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD006.html32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD007.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD007.html32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD008.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_LWD008.html32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_Well_Composite_.dlis32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_Well_Composite_.html32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_2MD.Pdf32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_2TVD.Pdf32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_5MD.Pdf32022EDDigital DataC2/5/2020 Electronic File: CPAI_CD5-96L1_Scope_Service_RM_5TVD.Pdf32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD27 EOW Compass Surveys.pdf32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD27 EOW Compass Surveys[Canvas].txt32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD27 EOW Compass Surveys[Macro].txt32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD27 EOW Compass Surveys[Petrel].txt32022EDDigital DataMonday, April 20, 2020AOGCCPage 2 of 4
DATA SUBMITTAL COMPLIANCE REPORTAPI No. 50-103-20811-60-00Well Name/No. COLVILLE RIV UNIT CD5-96L1Completion Status1-OILCompletion Date1/27/2020Permit to Drill2191630Operator ConocoPhillips Alaska, Inc.MD24463TVD7457Current Status1-OIL4/20/2020UICNoWell Cores/Samples Information:ReceivedStart Stop CommentsSentSample SetNumberNameIntervalINFORMATION RECEIVEDCompletion ReportProduction Test InformationGeologic Markers/TopsY Y / NAYMud Logs, Image Files, Digital DataComposite Logs, Image, Data Files Cuttings SamplesY / NAYY / NADirectional / Inclination DataMechanical Integrity Test InformationDaily Operations SummaryYY / NAYCore ChipsCore PhotographsLaboratory AnalysesY / NAY / NAY / NACOMPLIANCE HISTORYDate CommentsDescriptionCompletion Date:1/27/2020Release Date:11/27/2019C2/5/2020 Electronic File: CD5-96L1 NAD27 EOW Compass Surveys[Surveys].txt32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD83 EOW Compass Surveys.pdf32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD83 EOW Compass Surveys[Canvas].txt32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD83 EOW Compass Surveys[Macro].txt32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD83 EOW Compass Surveys[Petrel].txt32022EDDigital DataC2/5/2020 Electronic File: CD5-96L1 NAD83 EOW Compass Surveys[Surveys].txt32022EDDigital Data0 0 2191630 COLVILLE RIVER UNIT CD5-96L1 LOG HEADERS32022LogLog Header ScansMonday, April 20, 2020AOGCCPage 3 of 4
DATA SUBMITTAL COMPLIANCE REPORTAPI No. 50-103-20811-60-00Well Name/No. COLVILLE RIV UNIT CD5-96L1Completion Status1-OILCompletion Date1/27/2020Permit to Drill2191630Operator ConocoPhillips Alaska, Inc.MD24463TVD7457Current Status1-OIL4/20/2020UICNoComments:Compliance Reviewed By:Date:Monday, April 20, 2020AOGCCPage 4 of 4M. Guhl4/20/2020
DLB 04/16/2020
From:Beat, Andrew T
To:Loepp, Victoria T (CED)
Subject:RE: [EXTERNAL]Re: CD5-96 (219-163) BOP Use
Date:Wednesday, January 22, 2020 8:20:33 AM
Ah yes! I forgot about the reporting template. I will send another email following the bulletin.
Thanks,
Andrew
(303) 378-8881
From: Loepp, Victoria T (CED) <victoria.loepp@alaska.gov>
Sent: Wednesday, January 22, 2020 7:32 AM
To: Beat, Andrew T <Andrew.T.Beat@conocophillips.com>
Subject: [EXTERNAL]Re: CD5-96 (219-163) BOP Use
Andrew,
Please see AOGCC bulletin 10-003 for guidance on reporting BOP use. Components used must be
tested next time TOOH.
Thanx,
Victoria
Sent from my iPhone
On Jan 22, 2020, at 7:10 AM, Beat, Andrew T <Andrew.T.Beat@conocophillips.com>
wrote:
Victoria,
Yesterday (1/21) when we got on bottom for a cleanout run inside casing, we had a
little gas breakout at surface on bottoms up. We shut in the annular to divert fluid to
the gas buster. No pressure was observed and the well was static before and after
circulating. We are about to lay down our cleanout assembly and will retest the annular
at that point.
Let me know if you have any questions.
Thanks,
Andrew
(303) 378-8881
From:Beat, Andrew T
To:DOA AOGCC Prudhoe Bay
Cc:Loepp, Victoria T (CED); Hobbs, Greg S; Doyon 25 Company Man; Alexa, Kurt J; Njoku, Johnson
Subject:BOPE Use Report - Doyon 25 on CD5-96L1 (219-163)
Date:Wednesday, January 22, 2020 8:39:23 AM
Good morning,
CD5-96L1 (219-163)
At 7:30 AM on 1/21/20, Doyon 25 closed its annular to divert fluid through the gas buster. After
getting to bottom with a casing cleanout BHA, a gas bubble was observed at surface after circulating
a bottoms up. Once the bubble was circulated out of the annulus a flow check was performed and
the well was static. We will retest the annular to 2500 psi once the rig is out of hole with the
cleanout BHA. The BOPE was last tested on 1/18/2020.
Please let me know if you have any questions.
Thank you,
Andrew Beat
Senior Drilling Engineer
ConocoPhillips Alaska
(303) 378-8881 cell
(907) 265-6341 office
WELL PERMIT CHECKLIST Field & Pool COLVILLE RIVER, ALPINE OIL - 120100
Well Name: COLVILLE_RIVER UNIT_CD5-96L1 Program DEV_ — Well bore seg �/❑
PTD#:2191630 Company ConocoPhillips Alaska, Inc. _ — _- _ Initial Class/Type —_
DEV / PEND ___GeoArea 890 Unit 50360 On/Off Shore On — Annular Disposal ❑
Administration
1
Permit fee attached
NA
2
Lease number appropriate
Yes
3
Unique well name and number
Yes
4
Well located in -a defined -pool
Yes
5
Welllocatedproper distancefromdrilling unit boundary -
Yes
6
Welllocatedproper distance from other wells-
Yes
7
Sufficient acreage available in drilling unit
Yes
8
If deviated, iswellboreplat included -
No -
;9
Operator only affected party - -
Yes
10
Operator has appropriate bond in force
Yes -
- -
11
Permit -can be issued without conservation order_ -
Yes
Appr Date
12
Permit can be issued without administrative approval
Yes
DLB 11/18/2019
13
Can permit be approved before 15 -day wait
Yes
14
Well located within area and -strata authorized by Injection Order# (put 10# in comments) (For
NA
15
All wellswithin1/4-mile-area of review identified (For service well only) - - -
NA
16
Pre -produced injector: duration -of pre -production less than 3 months (Forservicewell only)
NA- -
17
Nonconven. gas conforms to AS31.05.0300.1.A),0.2.A-D)
NA
18
Conductor stringprovided- -
NA
Second lateral from existing wellbore -
Engineering
19
Surface casing protects all known- USDWs -
NA
Second lateral from existing wellbore
20
CMT vol- adequate_ to circulate on conductor -& surf csg
NA
Second lateral from existing wellbore
21
CMT -vol adequate -to tie-in long string to surf csg
NA
Second lateral from existing wellbore, plop and drop slotted liner lateral -
22
CMT will cover all known productive horizons- - -
NA
Second lateral from existing wellbore, plop and drop slotted liner lateral -
23
Casing designs adequate for C, -T-, B & permafrost
Yes
24
Adequate tankage or reserve pit
Yes
Doyon 25 has good truck support and adequate tankage -
25
If a re -drill, has a 10-403 for abandonment been approved
NA
26
Adequate wellbore separation proposed
Yes
Directional -plan passes CPAI separation criteria
127if-diverter
required, does it meet regulations
NA
Second lateral from existing wellbore, -plop and drop slotted liner lateral
Appr Date
28
Drilling fluid program schematic &- equip list adequate
Yes
All fluids overbalanced to pore pressure -
MGR 11/27/2019
29
BOPEs, do they meet regulation
Yes
3 ram, 1 annular tested to 3500 psi
30
BOPE press rating appropriate; test to -(put psig in comments)
Yes
5000 psi stack - -
31
i
Choke manifold complies w/API RP -53 (May 84)-
Yes
32
Work will occur without operation shutdown
Yes
33
Is presence -of H2S gas probable -
No
34
-Mechanical-condition of wells within AOR verified (For service well only) - -
NA-
This well is a producer
Geology
35
Permit can be issued w/o hydrogen sulfide measures
Yes
H2S not encountered in offset wells.- However, rig will be equipped with operational sensors/alarms.
36
Data presented on potential overpressure zones
Yes
Appr Date
37
Seismic analysis of shallow gas -zones
NA-
DLB 11/18/2019
',38
Seabed condition survey -(if off -shore)
NA
I39
Contact name/phone for weekly -progress reports- [exploratory only] - - - - - - - -
NA
Geologic Engineering Public
Com
Date: Date Date
Commissioner: Commissioner: � si