Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutO 090INDEX OTHER ORDER NO. 90 SCU 42B-04 1. February 8, 2013 Hilcorp Alaska, LLC's (HAK) application to AOGCC regarding a spacing exception for SCU 42B-04 2. February 13, 2013 HAK's revised application to AOGCC regarding a spacing exception for SCU 42B-04 INDEX OTHER ORDER NO. 90 SCU 42B-04 Colombie, Jody J (DOA) From: Colombie, Jody J (DOA) Sent: Thursday, March 13, 2014 4:08 PM To: 'Kevin Tabler' Subject: RE: 2/8/13 Spacing Exception Application SCU 4213-04 Thank you! Jody From: Kevin Tabler [mailto:ktablerCa)hilcorp.com] Sent: Thursday, March 13, 2014 4:06 PM To: Colombie, Jody J (DOA) Cc: David Duffy Subject: 2/8/13 Spacing Exception Application SCU 4213-04 Jody: On February 8, 2013, Hilcorp Alaska, LLC submitted an application for spacing exception for the SCU 426-04 well. With the Commission's issuance of Conservation Order No. 12313, dated August 28, 2013, we would like to formally withdraw our application for said well. Kevin Kevin A. Tabler Land Manager, Alaska Hilcorp Alaska, LLC 3800 Centerpoint Drive, Suite 100 Anchorage, Alaska 99503 Office: 907 777-8300 Direct: 907 777-8379 Fax: 907 777-8580 Email: ktabler@hilcorp.com 1 FEB 15 2013 February 13, 2013 9 • Hilcorp Alaska, LLC Cathy Foerster, Chair Alaska Oil and Gas Conservation Commission 333 West 7"' Avenue, Suite 100 Anchorage, Alaska 99501 Post Office Box 244027 Anchorage, AK 99524-4027 3800 Centerpoint Drive Suite 100 Anchorage, AK 99503 Phone:907/777-8300 Fax: 907/777-8301 RE: REVISED Application for Administrative Spacing Exception per C.O. 123A for the Swanson River Field, Soldotna Creek Unit (Proposed Well SCU 4213-04) Dear Commissioner Foerster, On February 8, Hilcorp Alaska, LLC ("Hilcorp") requested administrative approval of an exemption to Rule 5 of Conservation Order 123A for proposed well SCU 4213-04. Since that date, Hilcorp has surveyed the location of the proposed well, and hereby submits updated information on the well's location: Surface Location: • Federal Lease A028997 2036' FNL, 361' FWL, Sec 3, T7N, R9W, SM, AK pre -survey statement: 1972' FNL, 355' FWL, Sec 3, T7N, R9W, SM, AK) Top of (Potential) Productive Horizon • Federal Lease A028997 • 1883' FNL, 10' FWL, Sec 3, T7N, R9W, SM, AK • pre -survey statement: 1843' FNL, 4' FWL, Sec 3, T7N, R9W, Seward Meridian, AK Projected Bottom Hole Location: • Federal Lease A028997 1513' FNL, 1234' FEL, Sec 4, T7N, R9W, SM, AK pre -survey statement: 1577' FNL, 1251' FEL, Sec 4, T7N, R9W, Seward Meridian, AK Nearest Location where Property Ownership Changes: • 4927' FEL of Federal Lease A028997 • pre -survey statement: 4920' FEL of Federal Lease A028997 As evident from the above -stated figures, the post -survey location of the proposed well do not differ significantly from Hilcorp's original location estimates. If you require additional information regarding this request, please contact Mr. Luke Keller, Drilling Engineer, at 777- 8395, or you may contact the undersigned at 777-8414. Sincerely, David W. Duffy CC: BLM #1 • RECEIVED February 8, 2013 Hilcorp Alaska, LLC Cathy Foerster, Chair Alaska Oil and Gas Conservation Commission 333 West 7 h Avenue, Suite 100 Anchorage, Alaska 99501 • Post Office Box 244027 Anchorage, AK 99524-4027 3800 Centerpoint Drive Suite 100 Anchorage, AK 99503 Phone:907/777-8300 Fax: 907/777-8301 RE: Application for Administrative Spacing Exception per C.O. 123A for the Swanson River Field, Soldotna Creek Unit (Proposed Well SCU 42B-04) Dear Commissioner Foerster, Hilcorp Alaska, LLC ("Hilcorp"), as Operator of the Swanson River Field, hereby requests administrative approval of an exemption to Rule 5 of Conservation Order 123A, which limits the number of oil wells in the Swanson River Field to two (2) wells per governmental quarter section! The location of proposed well SCU 42B-04 and relationship to adjoining properties and wells is depicted on attached Exhibit A, and is further summarized below: Surface Location: • Federal Lease A028997 • 1972' FNL, 355' FWL, Sec 3, T7N, R9W, Seward Meridian, AK Top of (Potential) Productive Horizon • Federal Lease A028997 • 1843' FNL, 4' FWL, Sec 3, T7N, R9W, Seward Meridian, AK Projected Bottom Hole Location: • Federal Lease A028997 • 1577' FNL, 1251' FEL, Sec 4, T7N, R9W, Seward Meridian, AK Nearest Location where Property Ownership Changes: • 4920' FEL of Federal Lease A028997 Based on seismic and subsurface data available to Hilcorp, this well is necessary to maximize the recovery of oil from the Hemlock Oil Pool. The proposed well targets un-drained reserves that cannot be reached by existing wells conforming to applicable spacing rules. If successful, this deviated well will be drilled to approximately 9,300' MD / 10,805' TVD. Hilcorp anticipates spudding this well in May 2013. Pursuant to Rule 5, a spacing exemption is required because SCU 4213-04's well path falls within the NE 1/4 of Section 4, Township 8 North, Range 8 West, which in turn contains two other wells ' C.O. 123A, Rule 7 (Administrative Approval) provides that "[u]pon request of the Operator and showing that all affected parties have been notified of such request, the Committee may authorize any operation reasonably designed to further the progress of the project and maximize the recovery of oil from the Hemlock Oil Pool in the Swanson River Field. Soldotna Creek Unit SCU 42B-04 Spacing Exception Application February 8, 2013 Page 2 of 3 (SCU 332-04 and SCU 42-04), both of which are capable of producing from the Hemlock within the same quarter section. See Exhibit A.2 The correlative rights of all affected owners, landowners and operators will be protected by approval of the requested exception. Hilcorp, as Operator, owns a 100% working interest in the Swanson River Field. The Bureau of Land Management owns the mineral interests associated with federal lease A A028997 and adjacent lease segments, and there are no other affected owners, landowners or operations within a'/2 mile radius of the proposed well. At the date of this mailing, a copy of this application was sent by certified mail to the only affected owner/landowner, the Bureau of Land Management. Also enclosed is an affidavit stating the undersigned is acquainted with the facts and verifying that all facts asserted herein are true. If you require additional information regarding this request, please contact Mr. Luke Keller, Drilling Engineer, at 777-8395, or you may contact the undersigned at 777-8414. Sincerely, David W. Duffy Hilcorp Alaska, LLC Enclosures: Affidavit, Exhibit A (map); certified mailing receipts. 2 Note: A portion of SCU 21-04's well path also passes through the NE'/4 of Section 4, but this well is not capable of producing within the same pool. Soldotna Creek Unit SCU 42B-04 Spacing Exception Application February 8, 2013 Page 3 of 3 VERIFIATION OF APPLICATION FOR SPACING EXCEPTION COOK INLET ALASKA SOLDOTNA CREEK UNIT Well 4213-04 I, DAVID W. DUFFY, Landman, Hilcorp Alaska, LLC, do hereby verify the following: I am acquainted with the application submitted for the drilling of the SCU 4213-in the Soldonta Creek Unit, Swanson River Oil Field. I have reviewed the application submitted for the exception to Rule 5 of Conservation Order 123A and assert that all the facts therein are true. I have reviewed the plat attached to said application and it correctly portrays the pertinent and required data for the Commission to take action on this request. DATED at Anchorage, Alaska this 9 day of February, 2013. I P-� Davi W. Duffy, Landm Hilcorp Alaska, LLC STATE OF ALAKSA ) ) ss THIRD JUDICIAL DISTRICT ) SUBSCRIBED TO AND SWORN before me this 18a' day of September, 2012 STATE OF A.SA�, &4X� NOTAREY NOVtIRY PUBLIC IN AND FOR Zelma M. CIar1.e T STATE OF ALSKA IM COrtrt4SSjon E)#u Nw 10, 2015 1 My Commission expires: j o ,;2o / (y El U.S. Postal Servicei,, CERTIFIED MAIL,. RECEIPT ru ru (Domestic Mail Only;urance Coverage Provided) N N � C Offin. M. Imam ti ti m m r-1 r --17pomae Postage $ ..0 .II rtified Fee O O Postmark C3 0Returnoeipt Fee Here 0 0 Required) O Delivery Fee O L7 Required) _n —0e & Fees r-1 ra Wayne M. Svejnoha, Branch Chief ru u sent Energy and Minerals N o o Pec Bureau of Land Management 222 West Seventh Avenue, #13 Anchorage, AK 99513-7504 • I SCU 13-34 B� I t h I• I I 9 A028399 SCU 33-33 BHL i S008NO09W ED SRU 24-33 BHL SCU-44-33 prop BHL SCU 21A404 BHL !SCU 21 SCU 42B-04 Bottom Hole Location (TD) / SCU 42-04 BHL SCU 12- SCU 332-04 BHL SCU 22-04 BHL,, SCU 22-04PB BHL F S007NO09W A021 SCU 43-04 BHL; SCU 43A-04 BHL° SCU 1 M 14 Hilcorp Alaska, LLC SCU 44-04 BHL SCU 41B-09 BHL SCU 41-09 BHL i` SCU 41A-09 Exhibit A Spacing Exception Soldotna Creek Unit SCU 42B-04 �34] SCU 24-34 BHL SCU 42B-04 Potential Top of Production Horizon SCU 12A-03 BHL BHL SCU 42B-04 Surface Hole Location SCU 236-03 BHL SCU 23A-03 BHL �} - -- - - - - 7� SCU 23-03 BHL `V Legend —�` • SCU 42B-04 SHL 314-03 BHL * X SCU 42B-04 TPH (G2) SCU 42B-04 BHL (TD) • Other Surface Well Locations 0 Other Bottom Hole Locations ---- Well Paths Q SRF Unit Boundary ■ 0 1,000 2,000 Feet N Alaska State Plane Zone 4, NAD27 Map Date: 2/7/2013