Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutDIU Endicott / BP ExplorationSTATE OF ALASKA AOGCC GAS DISPOSITION FILES 2005 FACILITY: DIU Endicott OPERATOR: BP EXPLORATION (ALASKA) INC STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION. COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Jan-2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Sold 6 144 668 Total Volume. . , Pool Name Pool Code Percent 7 Reinjected 11 182 997 Endicott 220100 99.74% . , , Sa Delta 220150 0.00% 8 Flared or vented 1 hour or less 1 064 Eider 220165 0.26°!0 . , 9 Flared or vented more than 1 hour (see instr ) 0 . . 10 Pilot and Purge 10 199 . , 11 Used for lease operations (specify in Remarks) 1 095 295 . , , 12 Other (see instructions) ~ Official Use Only . Authohzaflon >1 hr: MCF 13 TOTAL VOLUME (ITEMS 6-12) 12 434 223 Safety . , , MCF 14 NGL Gas Equivalent 128 377 Lease Use . , MCF 15 Purchased gas Conservation . Waste: MCF 16. Transferred from: 17 Transferred to: (Express as a negative #) Commissioner Date . i8. Remarks: Block 6. 16,291 mscf fuel gas sold; 128,377 mscf NGL gas equivalent sold Block 11. 22,383 mscf assist gas; 1,072,912 mscf fuel gas. I hereby certify that the foregoing is true a d cor o theist of my knowledge. ' Manager, Production Taxes and Royalties Note: All volumes must be Signature -~ Tine Alaska corrected to pressure of 14.65 psia ~ and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date ' L ~~ 2/4/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Jan-2005 Unplanned Events less than or equal to 1 hour .',DATE '-.TIME ? VOLUME ' DESCRIPTION OF INCIDENT &CAUSE ACTION'TAKENTO ELIMINATE CAUSE TOTAL 1,060 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour .;DATE TIME VOLUME DESCRIPTION OF INCIDENT &CAUSE ACTION TAKEN T fNATE CAUSE 0 TOTAL 0 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf '.DATE TIME `'VOLUME DESCRIPTION OF INCIDENT'&CAUSE ' ACTION'TAKEN TO ELIMINATE CAUSE'. ....... 1/22/2005 1833-1834 4 Well 3-35 POP Adj. gas TOTAL 4 Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE 'TIME ' VOLUf11lE _ DESCRIPTION OF INCIDENT&CAUSE ACTION'TAKEN TO ELIMINATE CAUSE 0 TOTAL 0 TOTAL EIDR SDN '' ENDICOTT Volume flared less than 1 hr 1,064 3 0 1,061 Volume flared greater than 0 0 0 0 1 hr Pilot Purge 10,199 26 0 10,173 Assist Gas 22.383 ~ Q 22,326 TOTAL FLARED VOLUME 33,646 86 0 33,560 1of1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Feb-2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 123 747 Total Volume. 6. Sold , Pool Name Pool Code Percent 1 4 Endicott 220100 99.99% 7. Reinjected 0, 48,900 Sa Delta 220150 0.01 512 Elder 220165 0.00% 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 212 9 10. Pilot and Purge , 1 006 767 11. Used for lease operations (specify in Remarks) , , 0 Official Use Only 12. Other (see instructions) Authorization >1 hr: Safet MCF 11 138 589 y 13. TOTAL VOLUME (ITEMS 6-12) , , L s U MCF G G i 137 108 ea e se 14. N L as Equ valent , Cons rvati n MCF 1 P h e o urc 5. ased gas Waste: MCF 16. Transferred from: f i Commissioner Date 17. Trans erred to: (Express as a negat ve #) 18. Remarks: BIOCk 6. 15,610 mscf fuel gas sold; 108,137 mscf NGL gas equivalent sold Block 11. 20,449 mscf assist gas; 986,318 mscf fuel gas. I hereby certify that the f regoing is true nd ct to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be signature Title. Alaska corrected to pressure of 14.65 psia and to a temperature of 60o F. Printed Name Bernard a~n Phone (907)564-5028 Date 3/8/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Feb-2005 Unplanned Events less than or equal to 1 hour .DATE TIME ' 'VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE,CAUSE TOTAL 512 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE TIME ~ VOLUME DESCRIPTION OF'INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 0 TOTAL 0 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE _0 TOTAL 0 Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf .'DATE ' TIME VOLUME DESCRIPTION' OF'INCIDENT & CAUSE ACTION TAKEN' TO ELIMINATE'CAUSE 0 TOTAL 0 TOTAL EIDR SDN ENDICOTT Volume flared less than 1 hr 512 0 0 512 Volume flared greater than 0 0 0 0 1 hr Pilot Purge 9,212 0 1 9,211 Assist Gas 20,449 Q ~ 20,446 TOTAL FLARED VOLUME 30,173 0 4 30,169 1 of 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION M~~ 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition -2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of l 129 435 Total Volume. 6. So d , Pool Name Pool Code Percent i d 11 164 890 Endicott 220100 99.97% 7. Re njecte , ' Sa Delta 220150 0.03% 496 Eider 220165 0.01 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 0 10. Pilot and Purge 10,199 k i if i R 344 1 091 11. Used for lease operat ons (spec y n emar s) , , i i ~ Official Use Only 12. Other (see nstruct ons) Authorization >1 hr: Safet MCF TOTAL VOLUME ITEMS 6 12 12 396 364 y ( ) 13. - , , Lea e U MCF l t NGL G E i 112 393 s se en 14. as qu va , ti C MCF onserva on 15. Purchased gas Waste: MCF 16. Transferred from: ti Commissioner Date 17. Transferred to: (Express as a nega ve #) 1s. Remarks: Block 6. 17,042 mscf fuel gas sold; 112,393 mscf NGL gas equivalent sold Block 11. 22,781 mscf assist gas; 1,068,563 mscf fuel gas. I hereby certify that the foregoing is true a rect to a best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be signature Title Alaska corrected to pressure of 14.65 psia _ ~ and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date Y 4/6/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Mar-2005 Unplanned Events less than or equal to 1 hour DATE - TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO,ELIMINATE CAUSE TOTAL 496 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OFUNCIDENT & CAUSE ACTION TAKEN TO ELIMINATE'CAUSE' 0 TOTAL 0 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf rDATE TIME'.. VOLUME DESCRIPTION OF INCIDENT,&,CAUSE ACTION TAKEN TO ELIMINATE CAUSE 0 TOTAL 0 Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT &'CAUSE ACTION TAKEN<TO ELIMINATE CAUSE 0 TOTAL 0 TOTAL ' EIDR SDN ' ENDICOTT Volume flared less than 1 hr 496 0 0 496 Volume flared greater than 0 0 0 0 1 hr Pilot Purge 10,199 1 3 10,195 Assist Gas 22,781 2 ~ 22,773 TOTAL FLARED VOLUME 33,476 3 9 33,464 1 of 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition A r-2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of ld s 125 943 Total Volume. s. o , Pool Name Pool Code Percent i t R d 10 619 022 Endicott 220100 99.97% njec 7. e e , , Sa Delta 220150 0.01 Fl t d 1 h l 8 d 1 333 Eider 220165 0.02% are or ven our or ess . e , t 9 Fl d t d th 1 h i 419 r.) . are or ven e more an our (see ns Pil t 10 d P 9 870 an . o urge , if k 11 d f l ti i R U 1 043 046 y . se or ease opera ons (spec n emar s) , , Oth i t ti 12 ~ Official Use Only er (see ruc ons) . ns Authorization >1 hr: f t S MCF 13 TOTAL VOLUME ITEMS 6 12 11 799 633 y a e ~ t ~ ( ) . - , , L U MCF 14 E i l t NGL G 109 690 ease se . qu va en as , ti C MCF P 15 h d onserva on urc . ase gas Waste: MCF 16. Transferred from: ,~ ~~ ~' i ~ ~ ~~~~ 17 f ed t E ti # T Commissioner Date . rans err xpress as a nega ve ) o: ( is. Remarks: Block 6. 16,253 mscf fuel gas sold; 109,690 mscf NGL gas equivalent sold Block 11. 22,596 mscf assist gas; 1,020,450 mscf fuel gas. I hereby certify that the foregoing is true and correct to the best of my knowledge. / Manager, Production Taxes and Royalties Note: All volumes must be signature L~~l.f.1,L ~iVia~ Title. Alaska corrected to pressure of 14.65 psis and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date ~8 rj ~~~- 5/6/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Apr-2005 Unplanned Events less than or equal to 1 hour DATE TIME' VOLUME DESCRIPTION OF INCIDENT & CAUSE ' ACTION TAKEN'TO ELIMfNATE CAUSE TOTAL 973 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE 'TIME VOLUME ' DESCRIPT[ON' OFJNCIDENT & CAUSE ACTION TAKEN TO'ELIMINATE CAUSE 4/7/2005 0255-1127 380 Plant shut down and start-up Plant on production 4/9/2005 0421-0535 18 Plant swinging Adjusted wells 4/30/2005 1308-1454 21 Ambient rising Adjust Auto Choke TOTAL 419 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME' VOLUME ... DESCRIPTION OF INCIDENT & CAUSE ACTION'TAKEN TO ELIMINATE CAUSE 360 TOTAL 360 Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf ~ 'DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE . ACTION'TAKEN'TO ELIMfNATE CAUSE 0 TOTAL 0 TOTAL' EIDR 8DN ENDICOTT Volume flared less than 1 hr 1,333 0 0 1,333 Volume flared greater than 419 0 0 419 1 hr Pilot Purge 9,870 2 1 9,867 Assist Gas 22,596 ~ $ 22,588 TOTAL FLARED VOLUME 34,218 7 4 34,207 1 of 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Ma -2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 12 12 Total Volume. 6. Sold 8,8 Pool Name Pool Code Percent 1 7 024 Endicott 220100 99.90°/0 7. Reinjected 70, 0, Sa Delta 220150 0.00 /o 1 7 Eider 220165 0.10% 8. Flared or vented 1 hour or less 0,87 4 9. Flared or vented more than 1 hour (see instr.) ,808 10 199 10. Pilot and Purge , 1 71 212 11. Used for lease operations (specify in Remarks) ,0 , 0 Official Use Only 12. Other (see instructions) Authorization >1 hr: Safet MCF 11 2 y 4' ~~ 13. TOTAL VOLUME (ITEMS 6-12) ,995,93 Lease Use MCF 1 1 14. NGL Gas Equivalent 1 3,5 2 Conservation MCF 15. Purchased gas Waste: MCF 16. Transferred from: (~~~~ g~Z~~,t~~ G ommission r Date 17. Transferred to: (Express as a negative #) 1s. Remarks: Block 6. 15,300 mscf fuel gas sold; 113,512 mscf NGL gas equivalent sold Block 11. 23,054 mscf assist gas; 1,048,158 mscf fuel gas. I hereby certify that the foregoing is true a correc o the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be signature Title Alaska corrected to pressure of 14.65 psia (~ and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date '~ ~r~J Jr~ 6/6/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT May-2005 Unplanned Events less than or equal to 1 hour :DATE TIME VOLUME DESCRIPTION OF INCIDENT &CAUSE AGTION TAKEN TO ELIMINATE CAUSE TOTAL 4,931 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 Hour DATE <TIME '' '.VOLUME DESCRIPTION OF INCIDENT &CAUSE ACTION TAKEN TO ELIMINATE CAUSE 5/7/2005 1524-1908 83 P1907 SD Assist gas to keep flare clean 5/27/2005 2040-0000 3057 B Main tripped Reduced plant rates 5/28/2005 0000-0340 186 Booster down, C3 sts, & assist C3 comer. started, Booster on 5/28/2005 1836-2001 51 A Booster tripped, assist gas Started B Booster TOTAL 3,377 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf .:DATE TIME VOLUME DESCRIPTION!OF INCIDENT &CAUSE ACTIONTTAKEN''TOIELIMINATE CAUSE TOTAL 5,946 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE ' ' TIME VOLUME `DESCRIPTION,',OF INCIDENfi&CAUSE' ACTION TAKEN TO ELIMINATE CAUSE 5/15/2005 1604-1719 494 MI compressor startup 5/16/2005 1728-2255 163 MI Troubleshooting 5/17/2005 1000-1313 217 MI Turbine troubleshooting 5/17/2005 1337-1750 475 MI Turbine troubleshooting 5/17/2005 2037-2207 82 MI Turbine troubleshooting TOTAL 1,431 TOTAL ' EIDR' SDN, _ _ ENDICOTT Volume flared less than 1 hr 10,877 11 0 10,866 Volume flared greater than 4,808 4 0 4,804 1 hr Pilot Purge 10,199 10 0 10,189 Assist Gas 23.054 2~ 1 23,030 TOTAL FLARED VOLUME 48,938 48 1 48,889 1of1 RE: DIU Subject: RE: DIU From: "Fiedler-, Anne ~1" <:Fic~IIcAM@BP.com> Date: Fri, 15 Jul ?Ui)> 1 ~:1~: ~ 1 -(}800 To: Stephen Mcmains -"ste~c mc~~ai ls~;"u;.~~dn~in state.~ik.us~=~ Hello Steve, May was an unusually high month for flaring at Endicott. I talked to the board operator this afternoon, who looked in the log book, and provided some more details. If you and Jim still need more information, please call the Production Coordinator, Melody Broacha, at 564-4712 next week. (I'm heading on vacation tomorrow.) The largest flare events were caused by a variety of problems with the B main compressor. On May 19, a power supply was replaced. On 5/27, B main tripped off and was safed out on 5/28. There were multiple attempts to restart it on 5/29 and on 5/30 there was work on the anti-surge valve. Also, MI injection resumed in May 2005, for the first time since May 2004. Getting this compressor going again involved multiple starts while troubleshooting. Anne Fiedler Volume Accounting BP Exploration (Alaska) Inc. 907/564-5826 907/564-4094 (fax) f iedleam~wbp . com -----Original Message----- From: Stephen Mcmains [mailto:steve mcmainsi~~admin.state.ak.us] Sent: Friday, July 15, 2005 10:53 AM To: Fiedler, Anne M Subject: DIU Ann, In reviewing May Gas Disposition report for DIU, Jim noticed a volume flared or vented more than an hour or less has more than doubled the highest volume we seen in 5 years. Please research and provide an explanation for this higher than usual volume. Thanks Steve I of 1 7/18/2005 7:08 AM STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition June-2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 6 S ld 105 793 Total Volume. . o , Pool Name Pool Code Percent 9 078 509 Endicott 220100 99.95% 7. Reinjected , , Sa Delta 220150 0.00% t d 1 h l i Fl d 2 874 Elder 220165 0.05% our or ess or ven e t . are , th 1 h i t t d 9 Fl d 1 635 ns e more an our (see r.) . are or ven , i d 9 870 Purge 10. P lot an , if ti i R k 11 d f l U 948 809 ease opera ons (spec y n emar . se or s) , 12. Other (see instructions) 0 ~ Authorization >t hr: Offlcial,U9e'Ohly S f ~,w„. ' ] ~ ~~ MCF ITEMS 6 12 13 TOTAL VOLUME 10 147 490 a e ty ~ ( - ) . , , L U MCF i l t 14 NGL G E 91 697 ease se qu va en . as , C ti MCF 15 P h d onserva on urc gas . ase Waste: MCF 16. Transferred from: //"n/ ~-g-oS ti 1 d t E # T f ' C mission r Date ve o: ( xpress as a nega ) 7. rans erre 1t3. Remarks: Block 6. 14,096 mscf fuel gas sold; 91,697 mscf NGL gas equivalent sold Block 11. 22,259 mscf assist gas; 926,550 mscf fuel gas. I hereby certify that the f regoing is true an ect to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be Signature Tine Alaska corrected to pressure of 14.65 psis 7 ~ ~~ ~ and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907 564-5028 Date ~~ 7/8/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Jun-2005 ~Unpianned Events less than or equal to 1 hour DATE" TIME °<_VOLUME _ __ DESCRIPTION,OF INCIDENT.& CAUSE ACTION TAKEN TO ELIMINATE.CAUSE TOTAL 1,786 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour `DATE ' TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 6/19/2005 0524-0754 93 MI depressureing Assist gas 6/21/2005 0906-1204 1504 Lifted PSV while starting MGC Isolate PSV 6/25/2005 1007-1142 38 Wells slugging Adjust Choke TOTAL 1,635 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf "DATE' 'TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE' ACTION TAKEN TO ELIMINATE CAUSE TOTAL 1,088 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME' `DESCRIPTION OFJNCIDENT &'CAUSE ACTION TAKEN TO ELIMINATE CAUSE 0 TOTAL 0 Volume flared less than 1 hr Volume flared greater than 1 hr Pilot Purge Assist Gas TOTAL FLARED VOLUME TOTAL EIDR 2,874 2 1,635 1 SDN 0 0 ENDICOTT 2,872 1,634 9,870 5 0 9,865 22,25 12 Q 22.242 36,638 20 0 36,618 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Jul -2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 115 889 Total Volume. 6. Sold , Pool Name Pool Code Percent 10 042 736 Endicott 220100 99.95% 7. Reinjected ' Sa Delta 220150 0.03% Flared or vented 1 hour or less 8 759 1 ~ Eider 220165 0.02% . , h 1 h i t 4 699 an our (see ns r.) 9. Flared or vented more t , / 10 199 '~ 10. Pilot and Purge , if i k R 1 033 230 emar 11. Used for lease operations (spec y n s) , , ~ Official Use Only 12. Other (see instructions) Authorization >1 hr. f t S ~ /{ r MCF TEMS 6 12 O OLU E 11 208 512 y a e ~ j f b - ) 13. T TAL V M (I , , L U MCF G G i 101 560 ease se 14. N L as Equ valent , ti C MCF P h d onserva on 15. urc ase gas Waste: MCF 16. Transferred from: /-,~~ (~,/~_~ ~--r" d f'L 7 / ti # 1 f d t E T Commissio ner Date ve ) rans erre xpress as a nega 7. o: ( 18. Remarks: Block 6. 14,329 mscf fuel gas sold; 101,560 mscf NGL gas equivalent sold Block 11. 22,504 mscf assist gas; 1,010,726 mscf fuel gas. I hereby certify that the foregoing is true and co ect to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be Signature Title Alaska corrected to pressure of 14.65 psis ,D~ and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone 907)564-5028 Date ~~ 8/3/2005 BP EXPLORATION (ALASKA) tNC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Jul-2005 Unplanned Events less than or equal to 1 hour DATE''' TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ',ACTION TAKEN TO ELIMINATE CAUSE TOTAL 1,589 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE ' ?IME VOLUME DESCRIPTION OF INCIDENT & CAUSE 'ACTION TAKEN TO ELIMINATE CAUSE 7/9/2005 1501-2017 121 SDI shutdown. Assist gas to flare Restarted plant 7/10/2005 0523-0649 24 Plan! Upset Adj. Gas 7/24/2005 0712-1939 4554 Starting Bmain B main on TOTAL 4,699 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE' "TIME ' VOLUME DESCRIPTION OFJNCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 170 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 'DATE TIME ' VOLUME ' DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 0 TOTAL 0 TOTAL EIDR SDN ' `ENDtCOTT Volume flared less than 1 hr 1,759 0 0 1,759 Volume flared greater than 4,699 1 1 4,697 1 hr Pilot Purge 10,199 2 3 10,194 Assist Gas 2,04 `~ ~ ~~ TOTAL FLARED VOLUME 39,161 8 10 39,143 1of1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Au -2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 123 335 Total Volume. 6. Sold - , Pool Name Pool Code Percent Endicott 220100 99.57% 7. Rein ected ~ 9 795 533 Sa Delta 220150 0.04% 2 115 Eider 220165 0.39% 8. Flared or vented 1 hour or less , / i 265 ~ nstr.) 9. Flared or vented more than 1 hour (see ^ 1 199 10. Pilot and Purge 0, k i if i R 1 072 865 emar 11. Used for lease operat ons (spec y n s) , , 0 Official Use Only 12. Other (see instructions) Authorization >1 hr: Safet ~ .- MCF 312 11 004 y ~ ~ 13. TOTAL VOLUME (ITEMS 6-12) , , Le s e U MCF 1 4 a e s 14. NGL Gas Equivalent 08, 68 Conservation MCF 15. Purchased gas Waste: MCF 16. Transferred from: /~ ~ 7,(0 -DS~ mmission r Date 17. Transferred to: (Express as a negative #) 18. Remarks: Block 6. 14,867 mscf fuel gas sold; 108,468 mscf NGL gas equivalent sold Block 11. 22,293 mscf assist gas; 1,050,572 mscf fuel gas. I hereby certify that the foregoing is true an correct to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be signature Title Alaska corrected to pressure of 14.65 psis _~~ and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date J~~`--- 9/6/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Aug-2005 Unplanned Events less than or equal to 1 hour DATE " TIME ' VOLUME DESCRIPTION OF INCIDENT &CAUSE ACTION TAKEN TO ELIMINATE CAUSE''' TOTAL 2,014 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE TIME' VOLUME DESCRIPTION! OF INCIDENT &CAUSE ACTION TAKEN' TO ELIMINATE CAUSE 8/8/2005 1817-2001 185 "A" booster compressor shutdown/High ambient temp Restarted "B" after cooldown/assist gas 8/13/2005 0532-0656 80 Booster comp S/D Adj. Gas TOTAL 265 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION' OF INCIDENT &CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 101 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME '' DESCRIPTION'OFJNCIDENT'&.CAUSE ACTION TAKEN'TO ELIMINATE CAUSE 0 TOTAL 0 TOTAL EIDR' SDN END[CATT Volume flared less than 1 hr 2,115 8 1 2,106 Volume flared greater than 265 1 0 264 1 hr Pilot Purge 10,199 40 4 10,155 Assist Gas 22,2 $$ $ 22,197 TOTAL FLARED VOLUME 34,872 137 13 34,722 1 of 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Se -2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 124 223 Total Volume. 6. Sold , Pool Name Pool Code Percent Endicott 220100 98.86% 7. Reinjected 9,990,860 Sa Delta 220150 0.04% 1 629 Eider 220165 1.10% 8. Flared or vented 1 hour or less , i n 21 1 nstr.) 1 hour (see 9. Flared or vented more tha 8 10. Pilot and Purge 70 9, k 037 992 1 s) 11. Used for lease operations (specify in Remar , , 0 Official Use Only 12. Other (see instructions) Authorization >1 hr: Safet MCF 1 1 1 4 y Z) 13. TOTAL VOLUME (ITEMS 6-12) , ,785 6 Lease Use MCF 101 960 14. NGL Gas Equivalent , Conservation MCF 15. Purchased gas Waste: MCF 16. Transferred from: l~ /~ ,~j # f E i Commissioner Date ) 17. Trans xpress as a negat ve erred to: ( 18. Remarks: Block 6. 14,274 mscf fuel gas sold to EPC; 7989 mscf fuel gas sold to Badami; 101-,960 mscf NGL gas equivalent sold. Block 11. 21,760 mscf assist gas; 1,016,232 mscf fuel gas. I hereby certify that the foregoing is tr and corr t the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be Signature Title Alaska corrected to pressure of 14.65 psia ^Dr and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date 0" `~`.~ r 10/13/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Sep-2005 Unplanned Events less than or equal to 1 hour DATE' TIME' VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 1,588 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE '' 'TIME-' "VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 9/26/2005 1619-2226 211 Booster compressor down. Flare smoky. Add assist gas. TOTAL 211 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE' "TIME VOLUME DESCRIPTION O'F'1NCIDENT & CAUSE ACTION TAKEN TO'ELIMINATE'CAUSE TOTAL 41 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE'. TIME' VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 0 TOTAL 0 TOTAL EIDR SDN ENDICOTT Volume flared less than 1 hr 1,629 17 1 1,611 Volume flared greater than 211 2 0 209 1 hr Pilot Purge 9,870 109 4 9,757 Assist Gas 21,260 2~ ~ ~-~ TOTAL FLARED VOLUME 33,470 367 14 33,089 ~F , STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Oct-2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 779 109 Total Volume. 6. Sold , Pool Name Pool Code Percent 10 798 30 Endicott 220100 99.22 % 7. Reinjected , , 9 Sa Delta 220150 ° 0.04 /° 84 1 Eider 220165 0.74% 8. Flared or vented 1 hour or less ,0 9. Flared or vented more than 1 hour (see instr.) 63 199 10 10. Pilot and Purge , 299 1 093 11. Used for lease operations (specify in Remarks) , , 0 Official Use Only 12. Other (see instructions) Authorization >1 hr: Safet MCF 12 12 7 y ~ 3 13. TOTAL VOLUME (ITEMS 6-12) ,0 , 33 Lease Use MCF 1 1 14. NGL Gas Equivalent ,960 0 Conservation MCF 15. Purchased gas Waste: MCF 16. Transferred from: ~ /2 ~/3 ^~ '~C/ i Co missione Date ve #) 17. Transferred to: (Express as a negat i8. Remarks: Block 6. 14,811 mscf fuel gas sold to EPC; 623 mscf fuel gas sold to Badami; 94,345 mscf NGL gas equivalent sold. Block 11. 22,828 mscf assist gas; 1,070,471 mscf fuel gas. I hereby certify that the foregoing is tru and correct to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be Signature Title Alaska corrected to pressure of 14.65 psia D and to a temperature of 60o F. Printed Name Bernard . Ha'n Phone (907)564-5028 Date rTF,~ 11 /6/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Oct-2005 Unplanned Events less than or equal to 1 hour DATE- TIME" VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 337 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE TUNE 'VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 10/9/2005 1311-1705 24 Booster Flaring due to TA work Assist Gas has been added TOTAL 24 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION-TAKEN TO ELIMINATE CAUSE TOTAL 747 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME" VOLUME DESCRIPTION'AF'INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 10/8/2005 1123-1719 39 Water wash turbine Turbine stopped TOTAL 39 TOTAL ' EIDR SDN ENDICOTT Volume flared less than 1 hr 1,084 9 0 1,075 Volume flared greater than 63 0 0 63 1 hr Pilot Purge 10,199 76 4 10,119 Assist Gas ~.,$2_$ ~ `~ 22,650 TOTAL FLARED VOLUME 34,174 254 13 33,907 1 of 1 Y f ^ STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Nov-2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 673 116 Total Volume. s. sold , Pool Name Pool Code Percent 11 206 932 Endicott 220100 96.370% 7. Reinjected , , Sa Delta 220150 0.03 /° l 2 914 Eider 220165 3.60% ess 8. Flared or vented 1 hour or , i 1 h t h 224 ns r.) an our (see 9. Flared or vented more t 870 9 '~ 10. Pilot and Purge , if i R k 1 081 778 y emar n s) 11. Used for lease operations (spec , , 0 Official Use Only 12. Other (see instructions) Authorization >1 hr: Safet ~ / MCF 12 12 418 391 y ~ ~ 'r ) 13. TOTAL VOLUME (ITEMS 6- , , Lease Use MCF 102 510 14. NGL Gas Equivalent , Conservation MCF 15. Purchased gas Waste: MCF 16. Transferred from: ~ /~., C'~~ ti # Co missioner Date ve ) 17. Transferred to: (Express as a nega 18. Remarks: Block 6. 14,163 mscf fuel gas sold to EPC; 0 mscf fuel gas sold to Badami; 102,510 mscf NGL gas equivalent sold. Block 11. 22,338 mscf assist gas; 1,059,440 mscf fuel gas. I hereby certify that the foregoing is true d orrect to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be Signature Title Alaska corrected to pressure of 14.65 psia '1 !, and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date ~ ~ / ids ~~~ f ~ ~ 12/6/2005 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Nov-2005 Unplanned Events less than or equal to 1 hour -- DATE 'TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 2,705 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE .TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN. TO ELIMINATE CAUSE 11/18/2005 1110-1311 20 Plant upset Assist gas to flare 11/20/2005 1715-1827 58 "B" booster compressor shutdown Assist gas to flare 11/24/2005 1209-1814 28 Flare assist gas ~ LC~LSe (,,{~ 11/25/2005 1204-1354 12 LP gas to flare. Assist gas added. 11/26/2005 1415-1912 93 LP Flare from 1st stage MI Added Assist Gas 11/29/2005 1109-1254 9 booster psv leak assist gas added 11/30/2005 1335-1525 4 Well swing Adjust Well TOTAL 224 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE' TOTAL 209 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf -DATE TIME VOLUME DESCRIPTION-0F INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 0 Volume flared less than 1 hr Volume flared greater than 1 hr Pilot Purge Assist Gas TOTAL FLARED VOLUME TOTAL EIDR SDN ENDICOTT 2,914 105 1 2,808 224 8 0 216 9,870 355 3 9,512 $ $~ ~ ~~ 35,346 1,271 11 34,064 1of1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator BP 5. Month/Year of Disposition Dec-2005 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of 114 520 Total Volume. 6. Sold , Pool Name Pool Code Percent 10 982 557 Endicott 220100 % 96.65° 7. Reinjected , , Sa Delta 220150 ° 0.04 /° l 2 084 Eider 220165 3.31 ess 8. Flared or vented 1 hour or , i 270 nstr.) 9. Flared or vented more than 1 hour (see 199 10 % 10. Pilot and Purge , , i i R k 1 053 960 n emar 11. Used for lease operations (spec fy s) , , Official Use Only 12. Other (see instructions) 0 Authorization >1 hr: Safet MCF y ZO ~ 13. TOTAL VOLUME (ITEMS 6-12) 12,163,590 Lease Use C r MCF v 14. NGL Gas Equivalent 100,485 Conservation MCF 15. Purchased gas Waste: MCF 16. Transferred from: ///'''~~~ ~ 1~ / ~ D ` aie Co missione 17. Transferred to: (Express as a negative #) i8. Remarks: Block 6. 14,035 mscf fuel gas sold to EPC; 0 mscf fuel gas sold to Badami; 100,485 mscf NGL gas equivalent sold. Block 11. 23,193 mscf assist gas; 1,030,767 mscf fuel gas. I hereby certify that the foregoing is true an orrect to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be Signature Title Alaska corrected to pressure of 14.65 psia {~~ and to a temperature of 60o F. Printed Name Bernard W. Ha'n Phone (907)564-5028 Date ~" ~~~ 1 /5/2006 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL N0.202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Dec-2005 DATE TIME VOLUME '.'.DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 1,902 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION DFINCIDENT&OAUSE ACTION TAKEN TO ELIfVIINATE CAUSE 12/19/2005 1244-1741 45 Assist gas 12/29/2005 0834-1924 209 Plant upset Adjustments 12/30/2005 1246-1807 16 Assist gas TOTAL 270 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION'OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE, TOTAL 182 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME .'.'DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL 0 TOTAL EIDR SDN ENDICOTT Volume flared less than 1 hr 2,084 69 1 2,014 Volume flared greater than 270 9 0 261 1 hr Pilot Purge 10,199 338 4 9,857 Assist Gas 23,].93 ZC~$ ~ 22,416 TOTAL FLARED VOLUME 35,746 1,184 14 34,548 1of1