Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutPrudhoe Bay Unit GC 1 / BPSTATE OF ALASKA
AOGCC
GAS DISPOSITION FILES
YEAR: 2006
FACILITY: PBU GC 1
OPERATOR: BP EXPLORATION
t. Facility Number
0290000031
2 Facility Name
PBU GC 1
3 Field
4. Opera Month/Year of Diepdagdn
BP January
PBU - WOA
Disposition
Volume MCF
/
V
20. For production from multiple pods, list conbibutbn of eadl pod s • paona of
Total Volume.
e. Sow
0
Pod Name
Pod Code
Percent
7�
0
PRUDHOE
640150
98.07%
LISBURNE
640144
0.00%
9 Flared or vented1 nw or less
20738
MIDNIGHT SUN
640158
0.51%
PT MCINTVRE
640180
1.42%
9 Flared or vented more than 1 hour (see nstr.)
15,625
10. Rot and Rigs
51,453 •
11. Used for bas operations (specify in Remarks)
938,032
12. Other (see nstnktlonS)
0
Authorization >1 hr.
safety
ISp62 —
MCF
13. TOTAL VOLUME (REMS 6-12)
1,025,848
Leas Use
MCF
14. NGL Gas Equivalent
0
Coneenation
MCF
15. Purchased gas
0
Waste:
MCF
16. TratWsned fmrm
°
/
� S�0 -i0
/ Commissioner Debt
(Express as 17. Transferred to: (Expre a negative at CGF
- 62,637,413
1 8. Remarks: Block I L Fuel Gas = 938,032 rnscf and Assist Gas = 0 rnscf
I hereby celery that the foregoing
its
Signature
is true and correct to the best of my knowledge.
/�
rata Manager, Production Taxes and Royalty
corrected to pressure of 14.65 psis
horcity ity 20 AAC 25235. Note: AB volumes must be
and s 0 F.
Authority AC5.
ll dC.,, vv��
/
Printed Narne Bernard W. Hajny Phone (907)564 -5028 Date 1 2.-•"" j c — O /,ta
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Form 10-422 Rev. 1/2004
Submit in Duplicate
20,738
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
January 2006
1
(Unplanned Events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
1/18/2006 0110 -0208 1,208 Not required for unplanned events which
1/18/2006 0116 -0159 1,792 are less than or equal to 1 hour
1/18/2006 2336 -2359 80
1/21/2006 0026 -0045 1,319
1/21/2006 0412 -0419 243
1/21/2006 0653 -0658 1,910
1/22/2006 1625 -1640 2,208
1/22/2006 2049 -2112 3,194
1/26/2006 1319 -1418 8,194
1/26/2006 2211 -2218 73
1/28/2006 1132 - 1158 361
1/29/2006 2107 -2122 156
TOTAL
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
'Unplanned Events greater than 1 hour
1
TIME „,„. VOLUME DESCRIPTION OF INCIDENT & CAUSE. .<.".
DATE
1/1/2006 0001 -2400 5,996 See attachments
1/2/2006 0001 -2400
1/3/2006 0001 -1050
1/10/2006 1838 -2020
1/19/2006 0000 -0330
5,996
2,704
200
729
TOTAL 15,625
ACTION TAKEN TO ELIMINATE CAUSE .. r .
See attachments
Pape 1
2/8/2006
9:34 AM
!Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
1
DATE
DATE
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
TIME. , _ . . VOLUME., DESCRIPTION OF INCIDENT & CAUSE r ,,, ; , �,,. ACTION TAKEN TO EUMINATE CAUSE....,,,
See attachments See attachments
TOTAL
(Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
!
TIME
TOTAL
VOLUME
0
0
TOTAL
Unplanned Events c 1 Hour 20,738
Unplanned Events > 1 Hour 15,625
Planned Events c 1 hour and not 0
exceeding 5,000 MCF
i 51453! ✓
87,816
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
January 2006
DESCRIPTION OF INCIDENT & CAUSE.
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
2/8/2006
9:34 AM
6
FACILITY: GC1
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:01 24:00 23 Hrs 59Mins ❑ ❑ ❑ 5,996 MSCF
TOTAL VOLUME 5,996 MSCF
First Determination of Cause:
1. Annex flare knock out repair.
REPORT NO: 06 -0001
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 01 .Jan 2006
Action Taken to Stop Flaring:
1. Repairng ASAP to return to normal gas rates. Any clarification needed contact GC1 area manager.
Monday, January 23 2006 Page 1 of 1
FACILITY: GC1 DATE: 02 Jan 2006
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
First Determination of Cause:
1. Annex flare knock out repair
REPORT NO: 06 -0003
BPXA FLARE REPORT
PRUDHOE BAY
1. Flare/Relief Valve 00:01 24:00 23 Firs 59Mins ❑
❑ ❑ 5,996 MSCF
TOTAL VOLUME 5,996 MSCF
Action Taken to Stop Flaring:
1. Repairng ASAP to return to normal gas rates. Any clarification needed contact GC1 area manager.
Monday, January 23, 2006 Page 1 of 1
15
FACILITY: GC1 DATE: 03 Jan 2006
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:01 10:50 10Hrs 49Mins ❑ ❑ ❑ 2,704 MSCF
TOTAL VOLUME 2,704 MSCF
First Determination of Cause:
1. Annex flare knock out repair.
BPXA FLARE REPORT
PRUDHOE BAY
REPORT NO: 06-0006
Action Taken to Stop Flaring:
1. Repairng ASAP to return to normal gas rates. Any clarification needed contact GC1 area manager.
Monday, January 23, 2006 Page 1 of 1
D
FACILITY: GC1 DATE: 10 Jan 2006
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 18:38 20:20 1 Hrs 36Mins 0 ❑ ❑ 200 MSCF
TOTAL VOLUME 200 MSCF
First Determination of Cause:
1. Depressure F -pad HP flowlines.
BPXA FLARE REPORT
PRUDHOE BAY
Action Taken to Stop Flaring:
1. No response taken as this was deemed to be of short duration.
REPORT NO: 06 -0017
Monday, January 23, 2006 Page 1 of 1
FACILITY: GC1 DATE: 19 Jan 2006
BPXA FLARE REPORT
PRUDHOE BAY
REPORT NO: 06 -0040
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:00 03:30 3 Hrs 30 Mins ] ❑ ❑ 729 MSCF
TOTAL VOLUME 729 MSCF
First Determination of Cause:
1. Sk -18 IP compressor losing bite due to controtinstrumentation failure.
Action Taken to Stop Flaring:
1. No response was taken initially as this was deemed to be of short duration. EOA and WOA had to
eventually cut wells equaling 100 MMSCFD to stop the flaring.
Monday, January 23, 2006 Page 1 of 1
• FW: GPB Flaring
Subject: FW: GPB Flaring
From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com>
Date: Wed, 04 Jan 2006 09:42:53 -0900
To: steve_mcmains@admin.state.ak.us
CC: "Kurz, John" <john.kurz@BP.com >, "GPB, GCl Area Mgr" <GPBGClTL@BP.com>, "GPB, Environ TL" <GPBEnvironTL@BP.com>,
"GPB, Environ Advisor West" <GPBEnvironAdvisorWest@BP.com >, "Fiedler, Anne M" <Anne.Fiedler @BP.com >, "Benson, Gary A"
<Gary.Benson @BP.com>,7Pfeiffer, Jim A" <Jim.Pfeiffer@BP.com> , "Bolkovatz, Mike J;_ <BolkovMJQa BP.co -
To:
Steve McMains, AOGCC
steve mcmains @admin.state.ak.us
907 - 793 -1241, fax 907- 276 -7542
From: Hal Tucker, GPB Production Optimization Team Leader
GC1 annex flare knockout drum work was completed and oil rate increased
sufficiently to allow GC1 IP /LP compressors to load up at 10 :50 AM on
January 3. Total flare duration was 12.5 days. Total flare volume was
approximately 75.5 MMSCF.
If you require additional information, please don't hesitate to call me.
Hal Tucker
GPB Production Optimization TL
(907) 659 -4472
From. GPB, Optimization Engr
Sent: Friday, December 23, 2005 8:10 PM
To: ' steve mcmainsradmin.state_ak.ud
Cc: Kurz, John; GPB, GC1 Area Mgr; GPB, Environ TL; GPB, Environ
Advisor West; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A;
Bolkovatz, Mike J; Tucker, Hal E
Subject: GPB Flaring
To:
Steve McMains, AOGCC
steve mcmains@admin.state.ak.us
907 - 793 - 1241, fax 907- 276 -7542
From: Dwight Warner, Field Optimization Engineer (907 659 - 4382) for
1 of 2
14/2006 10:51 AM
FW: GPB Haring
Mike Bolkavatz, Prod Optimization Team Leader (907- 659 -5566)
On December 21 during routine corrosion inspection of the HP knock out
vessel V -9904 at GC1 -GHX a corrosion tattle tail on the boot connected
to the vessel developed a leak. An engineering inspection determined
that the equipment must be shut down for repair. The GHX plant was
shutdown at 21:00 on December 21. The GC1 plant stayed on line with
limited production at -50 mbpd and a gas rate of 1045 mmscfd the
normal through put is approximately 100 mbpd and 2.5 bcfpd. This shut
down resulted in a lack of IP /LP available gas for compressors K - 105
and K -107 which resulted in back pressure in V -136 which is relieving
to the LP system resulting in a clean vertical flare of approximately
6 mmscfd.
All potential and controllable options to reduce flare volume have
been taken into consideration and acted upon.
There are two crews working 24 hours a day to repair the vessel as
soon as possible. This requires a safe out and entry into the vessel
to inspect the welds that make up the water boot to the vessel. We
will not know the duration of the incident until the vessel has been
entered and inspected.
If you require additional information, please don't hesitate to call
me.
Dwight Warner - - Acting Prod Optimzation Team Lead
GPB Field Optimization Engineer
659 -4382
2 of 2 1/4/2006 10:51 AM
Question re GC -I Pilot Purge increase & "WHR"
Subject: Question re GC -1 Pilot Purge increase & "WHR"
From: "Benson, Gary A" <Gary.Benson @bp.com>
Date: Tue, 11 Apr 2006 10:18:35 -0800
To: Stephen Mcmains < steve _mcmains @admin.state.ak.us>, James Regg
jim_regg@admin.state.ak.us?
Steve & Jim,
I got this response from the GC-1 Ops Lead regarding the GC -1 pilot purge increase: ::;
"No Flare work was done. The pilot gas was increased due to black smoke, wisping. We are currently
max scale, above 480 mscfd. We are reducing that rate down to 400 mscfd immediately. The Rover is
aware of this situation and will be monitoring. The plant will also be surveyed to see if we have any
PSV's leaking."
WHR means "waste heat recovery".
Let me know if you need more information.
Gary Benson
Volume Accounting
Greater Prudhoe Bay
BP Exploration (Alaska)
(907) 564-4604
(907) 564 -4094 fax
bensongatbp.com
From: Stephen Mcmains [ mailto: steve _mcmains @admin.state.ak.us]
Sent: Tuesday, April 11, 2006 7:38 AM
To: Benson, Gary A
Subject: Re: PBU GC-1 Pilot Purge Increase
Gary,
What have you found out about this problem. CG -I pilot purge increase in January 2006 and the
acronyn for W FIR? We need to complete this ASAP.
Steve
Benson, Gary A wrote:
Thanks for the clarification Jim. I think it was the reference to the July to December 2005 period
that threw me off, whereas the flare tip was replaced August 2004.
Will get back to you ASAP with a response or to put you in contact with appropriate engineering
personnel.
1 of3 4/11/2006 10:41 AM
Question re GC -I Pilot Purge increase & "WHR"
Gary
From: James Regg (mailto:jim regq@admin.state.ak.usl
Sent: Wednesday, February 01, 2006 2:10 PM
To: Benson, Gary A; Steve McMains
Subject: Re: PBU GC -1 Pilot Purge Increase
Concern is the trend (continuing increase) of pilot purge gas usage as shown on the plot we
attached. If this increasing trend is linked to something specific - e.g., the flare tip changeout -
then it would be helpful to know what the usage volume will stabilize at (most other facilities
show stabilized rate for pilot -purge gas); if there are other reasons for the increasing trend. we
would like to know what they are.
Not sure if you were involved in the discussions at FS -3 but it turned out the increasing
volumes being reported were finally attributed to leakage past PSVs and the apparent lack of
testing and maintenance of those valves. Took some investigating/reviews to get to the real
cause. We want to make sure this or similar circumstances are not the case here.
Thank you for looking into this; if you prefer, I am available to discuss directly with appropriate
facility /engineering personnel.
Jim Regg
AOGCC
Benson. Gary A wrote:
Steve & Jim,
I've sent a note to the Slope requesting an explanation of the increased
pilot purge. Just to clarify, the volume has been in the 44- 45,000 mcf
per month range for 2005 until October when it jumped to about 50,000
mcf. So that's a 5 -6,000 mcf per month increase since October, not a
10,000 mcf per month increase since July. Or am I misunderstanding your
note below?
Gary
Original Message
From: James Regg [mailto:jim regq @admin.state.ak.ual
Sent: Tuesday, January 31, 2006 9:07 AM
To: Stephen Mcmains
Cc: Benson, Gary A
Subject: Re: PBU GC -1 Flaring Increase
Here's a graphic illustrating what Steve mentions below; note
that this pilot -purge
Jim Regg
AOGCC
Stephen Mcmains wrote:
2of3 4/11/200610:41 AM
Question re GC-1 Pilot Purge increase & "WHR"
3 of 3
Gary,
Please check this problem with the engineers on the slope.
PBU GC -1 flaring from July thru December 2005 shows a large volume
increase, an upward trend of over 10,000 mcf for the
period. Why the
large increase? Does this increase have anything to do
with flare tip
change out and if it does, what would the future target rate be for
the pilot purge at GC -1?
Looking back over the recent history (beginning April 2002
thru June
2005), it appears flaring increase 10,000 mcf in a 3 year
period and
recently there has been that much of an increase again. They had
flare tip change out last Summer.
Please provide an explanation of the increase flare for
this duration
and what BP will do to mitigate the problem leading to
larger volume
flared at GC -1.
Steve
4/I1/2006 10:41 AM
1. Facility Number
0290000031
2. Facility Name
PBU GC 1
3. Field
PBU - WOA
4. Operator 5. MontM'nr of Disposition
'BP February
Disposition
Volume MCF
> > 1 1
20. For production from multiple pools, list contribution of each pool as • percent of
Total Vokxne.
6. Sold
0
Pax Name
Pool Code
Percent
7 Reinjected
0
PRUDHOE
640150
98.21%
LISBURNE
640144
0.04%
e. Fixed or vented 1 hour or leas
15,119
MIDNIGHT SUN
640158
0.53%
PT MCINTYRE
640180
1.22%
9. Flared or vented more Man 1 how (see Fehr.)
4,979
to. Pilot and Purge
46,050
1 1. Used for base operations (specify fn Remarks)
759,734
Authorization >1 hr
Seb 7
4 171
1 !9
MCF
12. Other (see instructions)
0
13. TOTAL VOLUMEQTEM36 -12)
825,882
Lease Use
MCF
14. NGL Gas Equivalent
0
Consovation
MCF
15. Purchased gas
0
Waste:
MCF
18. Transferred Iran:
0
( ! t
�� /��/ " / t'�/ co migione oats
17. Transferred to: (Express as a negative 5) CGF
- 61,953,548
t e. Remarks: Block I I : Fuel Gas = 759 734 mscf and Assist Gas = 0 mscf
1 hereby certify that the • egoirg is true a • • • • : (0 1he best of my knowledge.
Signature Milo*
_ Sm.. Tide Manager, Production Taxes and Royalty
Note: All volumes must be
corrected to pressure of 14.65 psla
a ut a temperature
Authority 0 AAA 5. 60o F.
Authnrltv20AAf;M5.235.
.
Printed Nan Bernard . Hajny Phone (907)564 - 5028 Date -/ > �7
? l�! /�n
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
Hour
1
(Unplanned Events less than or equal to 1
VOLUME
338
163
92
33
535
8,750
496
1,757
2,955
DATE
2/3/2006
2/6/2006
2/6/2006
2/20/2006
2/20/2006
2/21/2006
2/21/2006
2/21/2006
2/27/2006
DATE
2/27/2006
2/28/2006
DATE
TIME
0051-0118
2201 -2219
2304 -2326
1721 - 1725
1730 -1744
1842 - 1924
1925 -1959
2124 -2146
0248-0323
TOTAL
TOTAL
TIME
TOTAL
TIME
TOTAL
Unplanned Events e 1 Hour
Unplanned Events > 1 Hour
Planned Events e 1 four and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Piet Pug.
Assist
TOTAL FLARED VOLUME
15,119
1
`Unplanned Events greater than 1 hour
TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE r2,r. . „�. ACTION TAKEN TO ELIMINATE CAUSE ,,,_,� y
2235 -2400 4,604 See attachments
0001 -0149 375
4,979
1
'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
VOLUME DESCRIPTION OF INCIDENT 6 CAUSE
See attachments
0
1
`Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
VOLUME DESCRIPTION OF INCIDENT & CAUSE.. . . ACTION TAKEN TO ELIMINATE CAUSE
TOTAL
15,119
4,979
0
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
February 2006
DESCRIPTION OF INCIDENT & CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
See attachments
Page 1
3/7/2006
10:17 AM
bp
FACILITY: GC1 DATE: 27 Feb 2006
TIME OF FLARING
SYSTEM Start Stop Duration Intermittent
1. Flare/Relief Valve 02:46 03:23 0 Hrs 37Mins
2. Flare/Relief Valve 22:35 24:00 1 Hrs 25Mins
Tuesday, February 28, 2006
REPORT t40:
BPXA FLARE REPORT
PRUDHOE BAY
Black
Smoke Planned
❑ ❑
❑ ❑
First Determination of Cause:
1. LPS compressor K -7000 & K -7001 shut down due to a problem associated with PLC.
2. LPS compressor K -7000 & K -7001 shut down due to a problem associated with PLC.
06 -0104
VOLUME
2,955 MSCF
4,604 MSCF
TOTAL VOLUME 7,559 MSCF
Action Taken to Stop Flaring:
1. WOA reduced production rates and shut -in 65 wells equaling 310 mmsctd. Wells were shut -in or
choked back starting at 0230 hours. Compressors restarted 0 0307 hours.
2. WOA reduced production rates and shut -in 65 wells equaling 310 mmscld. Wells were shut -in or
choked back starting at 2236 hours.
Page 1 of 1
et
FACILITY: GC1 DATE: 28 Feb 2006
BPXA FLARE REPORT
PRUDHOE BAY
REPORT NO: 06 -0105
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:01 01:49 1 Hrs 48Mins ❑ ❑ ❑ 375 MSCF
TOTAL VOLUME 375 MSCF
First Determination of Cause:
1. LPS compressor K -7000 & K -7001 shut down due to a problem associated with PLC.
Action Taken to Stop Flaring:
1. WOA reduced production rates and shut -in 78 wells equaling 400 mmscfd. Wells were shut -in @
2326 hours on 2/27. Leak by from HP to LP diverts on dual mode pads is cause for flaring after all
LP wells were shut -in.
Monday, March 06, 2006 Page 1 of 1
1. Facility Number
0290000031
2. Facility Name
PBU GC 1
3. Field
14 Operator
BP
5. MonftWear d Disposition
March - 2006
PBU - WOA
Disposition
Volume MCF
20. For production from multiple pods, list contribution of each pool as • percent of
Total Volume.
8. Sole
0
Pod Name
Pod Code
Portent
7 Reinjected
0
PRUDHOE
840150
98.41%
LISBURNE
640144
0.17%
9. Flared a vented 1 hour a less
a735
MIDNIGHT SUN
640158
0.38 °A
PT MCINTYRE
640180
1.01%
e. Flared
1 bar (see instil
5,322 v./
BOREALIS
640130
0.03%
vented more an
or ro
10. Pilot and Purge
50,888 ✓
11. Used to lease operations (specify in Remarks)
843,336
12. Other (see Instructions)
0
Authorization >I hr
Safety
S 3ZL
r
MCF
13. TOTAL VOLUME (ITEMS 612)
903,281
Lease Use
MCF
It NGL Gas Equivalent
0
Conservation
MCF
15. Prchasedgas
0
Waste:
MCF
16. Transferred front
0
J7 4- -- 8 40 0,6
Commissioner Date
17. Transferred to: (Express as • negative e1 CGF
- 74 587 938
It Remarks: Block I l: Fuel Gas = 843,336 inset and Assist Gas = 0 nisei
I hereby certify that the foregoing is tru M coned to the best of myu� rowledge.
I Note:
signature "Zfle roe Manager Production Taxes and Ro ally
All volumes must be
corrected to pressure of 14.65 psis
and to a temperature of 600 F.
Authority 20 AAC25.235.
Printed Name Bernard . Hajny Pne I90715e4 -502e
//
4
/
C`�
Data
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
1
(Unplanned Events less than or equal to 1 hour
TIME .. VOLUME DESCRIPTION OF INCIDENT & CAUSE
2301 -2333 1,111 Not required for unplanned events which
0420-0428 278 are Tess than or equal to 1 hour
DATE
3/11/2006
3/12/2006
3/12/2006
3/13/2006
3/13/2006
3/28/2006
3/31/2006
DATE
3/2/06 to 3/3/06
3/3/2006
3/31/2006
2237- 2256 264
1049 - 1138 442
1958 -2032 472
1528 -1532 139
2231 -2328 1,029
TOTAL
2202-0021
0338 -0530
1647 -2224
TOTAL
3,735
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC-1
GAS FLARING INCIDENT REPORT
February 2006
'Unplanned Events greater than 1 hour
VOLUME DESCRIPTION OF INCIDENT & CAUSE
3,122 See attachments
933
1,267
5,322
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
ACTION TAKEN TO EUMU4ATE CAUSE
See attachments
1
1
'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
VOLUME- DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO EUMINATE CAUSE ,
DATE
1
'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
TIME „;. VOLUME DESCRIPTION OF INCIDENT & CAUSE ....... ... ACTION TAKEN TO ELIMINATE CAUSE ..,
See attachments
Unplanned Events c 1 Hour
Unplanned Events > 1 Hour
Assist
TOTAL FLARED VOLUME
TIME
TOTAL
TOTAL
0
0
TOTAL
3,735
5,322
Planned Events c 1 Foam and not 0
exceeding 5,000 MCF
Planted Events > 1 hour or 0
exceeding 5,000 MCF
Pita Purge
IMPS MASS
0 '
59.945
See attachments
See attachments
See attachments
Pags 1
4/26/2008
10:22 AM
GPB Flaring
Subject: GPB Flaring
From: "GPB, Prod Opt TL" <GPBProdOptTL(a3BP.com>
Date: Sun, 05 Mar 2006 13:46:50 -0900
To sieve mcmains @admin.statak.us
CC: "Kurz, John" <john.karz@a BP.conP, "GPB, Environ TL" <GPBEnv ronTL@BP.com>, "GPB, ,Envi
Advisor West" <GPBEnvironAdvisorWest@a BP.com>, "Fiedler, Anne. M" .<Anne.Fiedier@BP.com>,
''Benson, Gary A" <Gary.Benson®BP com>, "Pfeiffer, Jim A" 4im.Pfeiff P.com >, "GPB, GCJ
To : Steve McMains, AOGCC
steve mcmainsOadmin.state.ak.us
907 - 793 -1241, fax 907 - 276 -7542
From: Hal Tucker, Prod Optimization Team Leader (907- 659 -4472)
Two extended flaring events occurred at GC1 last week. Both events
resulted from problems with GC1 process automation. The first event
began at 22:35 on February 27 and lasted for 3 hours and 13 minutes.
Total volume for this event was 4,979 MSFC. The second event began at
22:02 on March 2 and lasted for 2 hours 19 minutes, this event was
closely followed with a full plant shut down that caused a 1 hour and 52
minute flare event. Total volume for the second event series was 5,055
MSCF. After the first event, the process automation techs changed out a
bad power supply on an I/O processor. The second event resulted in a
change out of a data highway that was associated with the previously
worked on I/O processor.
An extended flare event is in progress at GC2. The event began at 0700
on March 2 when GC2 was shut down due to a leak in the oil transit line.
2 MMSCFD of stripping gas and water tank purge gas is being maintained
to keep the plant warm. We intend to maintain this condition until the
plant can be restarted. Likely duration of the shut down is unknown at
this time.
If you require additional information, please don't hesitate to call me.
Hal Tucker
GPB Production Optimization Team Leader
bp Exploration AK, Inc
(907) 659 -4472
1 of 1 3/6/2006 6:55 AM
C�
FACILITY: GC1 DATE: 02 Mar 2006
BPXA FLARE REPORT
PRUDHOE BAY
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 22:02 22:42 0 Hrs 4OMins ❑ ❑ ❑ 2,778 MSCF
2. Flare/Relief Valve 22:42 24:00 1 Hrs 18Mins ❑ ❑ ❑ 271 MSCF
TOTAL VOLUME 3,049 MSCF
First Determination of Cause:
1. LPS compressor K -7000 & K -7001 shut down due to a problem associated with PLC.
2. LPS compressor K -7000 & K -7001 shut down due to a problem associated with PLC.
REPORT NO: 06 -0106
Action Taken to Stop Flaring:
1. WOA reduced production rates and shut -in all LP wells equaling 400 mmscfd. Wells were shut -in
0 2242 hours.. Leak by from HP to LP diverts on dual mode pads is cause tor flaring after all LP
wells were shut -in.
2. WOA reduced production rates and shut -in all LP wells equaling 400 mmscfd. Wells were shut -in
2242 hours. Leak by from HP to LP diverts on dual mode pads is cause for flaring after all LP
wells were shut -in.
Monday, March 27, 2006 Page 1 of 1
r
6P
FACILITY: GC1 DATE: 03 Mar 2006
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:00 00:21 0 Hrs 21 Mins ❑ ❑ ❑ 73 MSCF
2. Flare/Relief Valve 03:38 05:30 1 Hrs 52Mins ❑ ❑ ❑ 933 MSCF
TOTAL VOLUME 1,006 MSCF
First Determination of Cause:
1. LPS compressor K -7000 & K -7001 shut down due to a problem associated with PLC.
2. Stop Production shut down due to PLC problem.
REPORT NO: 06-0108
BPXA FLARE REPORT
PRUDHOE BAY
Action Taken to Stop Flaring:
1. WOA reduced production rates and shut -in all LP wells equaling 400 mmscfd. Wells were shut -In
2242 hours. Leak by from HP to LP diverts on dual mode pads is cause for flaring after all LP
wells were shut -in.
2. Completed GC shut down. Flare was due to flare assist gas.
Monday, March 27, 2006 Page 1 of 1
FACILITY: GC1 DATE: 31 Mar 2006
BPXA FLARE REPORT
PRUDHOE BAY
REPORT NO:
Action Taken to Stop Flaring:
1. Normal plant start up, not enough gas to run LP and IP compressors.
2. WOA reduced production rates and shut -in 17 wells equaling mmscfd. Wells were shut -in or
choked back starting at 2235 hours.
06 -0174
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 16:47 22:24 5 Hrs 4Mins 0 ❑ ❑ 1,267 MSCF
2. Flare/Relief Valve 22:31 23:28 0 Hrs 57Mins ❑ ❑ ❑ 1,029 MSCF
TOTAL VOLUME 2,296 MSCF
First Determination of Cause:
1. Hardware problems with data highway. Total plant shut down, started flaring from LP 100 with
assist gas.
2. While bringing production rates up following K -7000 LPS compressors would not load up and
discharged to flare.
Tuesday, April 04, 2006 Page 1 of 1
1, Facility Number
2. Facility Name
PBU GC 1
3- Field
4. Opsralar 5. Ma16Ww d Disposition
1 BP April-2008
PBU - WOA
Disposition
Volume MCF
20. For production from multiple pools, ask oOnMWtlon of oath pod as • percent of
Total Volume.
9. Sold
0
Pod Name
Pool Code
Percent
7 Reinjected
0
PRUDHOE
640150
97.47%
LISBURNE
640144
0.18%
8. Flared or vented t Inure less
15,567
MIDNIGHT SUN
640158
0.44%
PT MCINTYRE
840180
1.73%
9. Flared a vented m (amine.) Man 1 hour (a i e.)
0
BOREALIS
640130
0.079'0
AURORA
640120
0.11%
10. Pilot and Purge
44,164
I 1. Used for lease operations (specify In Remarks)
799,121
12. Omer (see instructions)
0
•. —.
Autlwma0orr >7 hr.
Safety
MCF
13. TOTAL VOLUME (ITEMS 6-12)
858,852
Lease Use
MCF
14. NOL Gas Equivalent
0
Conservation
MCF
15. Purchased gas
0
Waste:
MCF
18. Tanshrred from:
0
Cammsa/3w Dab
17. Transferred to: (Express as a negative s) CGF
-70,855,202
18. Remarks: Block I I: Fuel Gas =799,121 mscf and Assist Gass 0 Duct
I hereby certify that mewing
is true a correct ol my k nowledge.
The Manager, Production Taxes and Royalty
Note: All volumes must be
corrected to pressure of 14.65 psis
and to a temperature of 60o F.
Authorlty 20 AACe5235.
Signature /
Primed Nana Bernard W. Hajny Phone (907)564 4028 Date V/
Form 10-422 Rev. 1 /2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
1
!Unplanned Events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
4/1/2006 0234 -0239 347 Not required for unplanned events which
4/2/2006 1032 -1121 170 are less than or equal to 1 hour
4/8/2006 0033-0106 688
4/8/2006 0406-0418 250
4/13/2006 2335 -2342 243
4/14/2006 0751-0757 417
4/16/2006 1118-1127 63
4/17/2008 1230-1327 13,063
4/17/2006 2107 -2114 243
4/18/2006 0706-0712 83
TOTAL 15,567
!Unplanned Events greater than 1 hour
1
DATE
1Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
1
DATE .,,, ..
DATE ._._..
TOTAL
TOTAL
VOLUME
TIME
TOTAL
VOLUME,
!Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
1
, VOLUME
TOTAL
Unplanned Events < 1 Hour 15,567
Unplanned Everts> 1 Hour 0
Planned Events < 1 hour and not 0
exceeding 5,000 MCF
Planned Everts > 1 hour or 0
exceeding 5,000 MCF
Pilot Purge ® 44,164
Assist O
TOTAL FLARED VOLUME 59,731
0
0
0
SP EXPLORATION (ALASKA) INC.
PRUDHOE SAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
April 2006
DESCRIPTION OF INCIDENT • CAUSE„ - _
See attachments
DESCRIPTION OF INCIOEHT & CAUSE ...
See attachments
DESCRIPTION OF INCIDENT & CAUSE ,, .,.,,:.
See attachments
ACTION 'TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
ACTION TAKEN TO ELIMINATE CAUSE , r ,,,,.�,,,�„„
See attachments
ACTIN TAKEN TO ELIMINATE CAUSE,
See attachments
ACTION TAKEN TO ELIMINATE CAUSE, ;w ",7
See attachments
Page 1
6/ar2oo6
10:16 AM
1 Facility Number
0290000031
I Facility
12. F Name
PBU GC 1
3. Field
4. Operator
IBP
Ww
15. Monlr of D eposita'
May - 2006
PBU - WOA
Disposition
Volume MCF
20. For producton from multiple pools. list contribution of sect pool as percam of
Total Vohrme
e. Sold
0
Pod Name
Pod Code
Percent
7 Reinjected
0
PRUDHOE
640150
96.78%
LISBURNE
640144
0.18%
9. Flared or vented t hour or less
MIDNIGHT SUN
640158
0.57%
PT MCINTYRE
640180
2.47%
s Flared or vented more than 1 hour (see duo.)
0
BOREALIS
640730
0.00%
AURORA
640120
0.00%
10. Pilot and Purge
44,099
11. Used for lease operations (specify Si Remarks)
843,896
12. Other (see kubudi0m)
0
Authorization >1 hr.
Sam
MCF
13. TOTAL VOLUME (ITEMS 612)
888,030
Lease Use
MCF
14. NGt. Gas Equivalent
0
Conservation
MFG
15. Purchased gas
0
Waste:
MCF
18. Transferred from:
0
Commissioner Date
17. Transferred to: (Express as a negative 0) CGF
- 62,397,294
te. Remarks: Block 11: Fuel Gas = 843,896 mscf and Assist Gas = 0 mscf
1 hereby certify that the to gdnq is true an coin o the test of my knowledge.
Signature rite Manager,
Production Taxes and Royalty
Date is -�
4
4
Note: All volumes must be
corrected to pressure of 14.65 psis
an d to a temperature of 60o F.
Atrthnety 70 A4C25 095.
Printed Name Bernard W. Hajny Phone (907)564 -5028
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
1
'Unplanned Events Tess than or equal to 1 hour
DATE .. TIME ,,:. VOLUME , DESCRIPTION OF INCIDENT & CAUSE
5/12/2006 1750 -1755
(Unplanned Events greater than 1 hour
1
DATE,„ ,
DATE , , , - ,,
TOTAL
TIME
TOTAL
1
(Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
DESCRIPTION OF INCIDENT & CAUSE ,, ACTION TAKEN TO ELIMINATE
See attachments See attachments
TOTAL
(Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
1
TOTAL
Unplanned Events c 1 Hour
Unplanned Events • 1 Hour
Planned Events c 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
VOLUME,,,,; DESCRIPTION OF INCIDENT & CAUSE,,,,, .,
See attachments
VOLUME
VOLUME
35 Not required for unplanned events which
are less than or equal to 1 hour
35
0
0
0
TOTAL
35
0
0
0
MINE 44149
0
44,134
BP EXPLORATION (ALASKA) INC.
PRUDHOE SAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
May 2006
DESCRIPTION OF INCIDENT & CAUSE,,
See attachments
� "; , ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
r ACTION TAKEN TO ELIMINATE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE , ,,,tl, i gnyty
See attachments
Pape 1
8/8/2006
1:48 PM
GPB Flaring
Subject: GPB Flaring
From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com>
Date: Tue, 09 May 2006 14:43:20 -0800
To: sieve mcmains @admin.state.ak.us
GC: "Kurz, John" <john-kurz@BP.com >, "GPB, Environ TV' <GPBEnvironTL@BP.com>, "GPB,
Advisor West" <GPBEnvironAdvisorWest@BP.com >, "Fiedler, Anne M"
<Anne.Fiedler@BP.com >, "Benson, Gary A" <Gary.Benson@BP.com >, "Pfeiffer, Jim A "
;Ciim.Pf P.coaP% "GPB,'GC1 Ant Mir" ..<GPBGC1 QFP: S
To: Steve McMains, AOGCC
steve_mcmains @admin.state.ak.us
907 - 793 -1241, fax 907 - 276 -7542
From: Michael Bolkovatz, Prod Optimization Team Leader (907- 659 -5566)
An extended flaring event occurred at GC1 from April 30 to May 7. During this period, the ambient
temperature increased from -5 to +20 deg. The GC1 LP /IP compressor bundles were originally designed
to pump a heavier mole weight gas and these machines are scheduled to be rewheeled this summer
due to their inability to handle leaner gas now coming from the reservoir. The combination of increasing
ambients and the inability of the GC1 LP /IP compressors to pump leaner gas resulted in intermittent
flaring. Gas production from GC1 has been reduced to prevent this condition from continuing.
Intermittent flaring occurred over 34 hrs and 53 minutes, total volume flared was 10,174 MSCF
If you require additional information, please don't hesitate to call me.
Michael Bolkovatz
GPB Production Optimization Team Leader
bp Exploration AK, Inc
(907) 659-5566
i,of 1 5/21/2006 9:13 AM
1 Facility Number
0290000031
2. Facility Name
PBU GC 1
3. Field
I BP
4. Operator 5. Mgn Year ol Dbpatiticn
June - 2006
PBU - WOA
Disposition
Volume MCF
/
20. For production from multiple pooh. Bat contribution of each pod as a potent W
Total Volume.
8. Sold
0
Pod Name
Pod Code
Percant
7. Re reined
0
PRUDHOE
640150
95.42%
LISBURNE
640144
0.23%
8. Flared or yarned 1 hour or !ass
11,101 Y
MIDNIGHT SUN
640158
0.77%
PT MCINTYRE
640180
3.58%
m
9. Flared or vented more an 1 how (see Instr.)
29,832 J
BOREALIS
640130
0.00%
AURORA
640120
0.00%
10. Pitt and Purge
42,415 1
11. Used for lease operations (specify in Remarks)
710,569
12. Omer (see Instructions)
0
Authorization >1 hr.
Safety
2-9 8.32°-
r
MCF
13. TOTAL VOLUME (ITEMS 8-12)
793,917
Lease Use
MCF
14. NGL Gas Egtavalem
0
Conaervauon
MCF
15. Purchased gas
0
Waste:
MCF
16. Transferred from:
0
/ Q 0 /� _ -04
£Z4 P m a�l i . Date
17. Transferred to: (Express as a negative r) COIF
- 47,371,255
it Bemen: Block 11: Fuel Gas = 710,569 mscf and Assist Gast 0 mscf
I hereby certify that the foregoing is true and -. to . best of my knowledge.
Signature _ ` Title Manager, Production Taxes and Royalty
Note: All volumes must be
corrected to pressure of 14.65 psis
and to a temperature of 60o F.
Authority 20 AAC25.235.
Printed Name Bemard W. Hajny Phone (907)564-5028 Date 7"t/C'& 7
Form 10 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
(Unplanned
Events less than
or equal to 1 hour
1
DATE
6/1/2006
6/22/2006
6/22/2006
6/23/2006
6/24/2006
6/25/2006
6/27/2006
6/28/2006
6/28/2006
6/28/2006
6/29/2006
6/29/2006
6/29/2006
6/29/2006
DATE
6/2/2006
6/21/2006
6/22/2006
6/22/2006
6/22/2006
6/22/2006
6/23/2006
TIME :u
2308 -2350
1538 -1635
2150 -2220
1639 -1700
1011 -1024
0254 -0340
0913 -0921
1024 -1040
1202 -1212
1346 -1404
0909 -0928
1438 -1501
1527 -1550
1642 -1656
TOTAL
TIME „
0555 -0710
2009 -2400
0000 -0130
0225 -0415
1250 -1410
1652 -1840
0000 -1308
TOTAL
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
June 2006
VOLUME DESCRIPTION OF INCIDENT & CAUSE
8,750 Not required for unplanned events which
396 are less than or equal to 1 hour
417
131
54
192
67
1,000
14
25
13
16
16
10
11
VOLUME DESCRIPTION OF INCIDENT & CAUSER.
15,313 See attachments
4,000
1,500
1,146
556
750
6,567
29,832
xu ACTION TAKEN TO EUMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
'Unplanned
Events greater than 1 hour
1
ACTION TAKEN TO EUMINATE
See attachments
Page 1
7/12/2006
9:54 AM
(Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
DATE„,„,,,„„, TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO EUMINATE CAUSE„, ,, I
See attachments
TOTAL
0
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT • GC -1
GAS FLARING INCIDENT REPORT
June 2006
See attachments
$Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
DATE „ amn TIME. m , VOLUME „p DESCRIPTION OF INCIDENT & CAUSE.,,,,,..„ „,„,,,, ACTION TAKEN TO EUMINATE CAUSE, „„„„
See attachments See attachments
TOTAL
Pilot Purge
Assist
TOTAL FLARED VOLUME
0
TOTAL
Unplanned Events c 1 Hour 11,101
Unplanned Events > 1 Hour 29 832
Planned Events c 1 hour and not 0
exceeding 5,000 MCF
Planned Events > 1 hour or 0
exceeding 5,000 MCF
42,41&
0
83,348
Page 2
7/12/2006
9:54 AM
FACILITY: GC1 DATE: 02 Jun 2006
BPXA FLARE REPORT
PRUDHOE BAY
REPORT NO: 06-0264
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 05:55 07:10 1 Hrs 15Mins ❑ ❑ ❑ 15,313 MSCF
TOTAL VOLUME 15,313 MSCF
First Determination of Cause:
1. High gas transit line pressure caused by CGF compressor problems due to both boosters S/D due
to instrument problems. GC -1 opened annex flare valve to flare 300mm.
Action Taken to Stop Flaring:
1. WOA reduced production rates and shut -in 41 wells equaling 278 mmscfd. Wells were shut -in or
choked back starting at 0555 hours.
Friday, June 30, 2006 Page 1 of 1
FACILITY: GC1 DATE: 21 Jun 2006
BPXA FLARE REPORT
PRUDHOE BAY
TIME OF FLARING
SYSTEM Start Stop Duration
1. Flare/Relief Valve 20:09 24:00 3 Hrs 51 Mins ❑
First Determination of Cause:
1. Plant shutdown - insufficient gas to load LP compressor. Assist gas added to prevent black smoke
Action Taken to Stop Flaring:
1. restarting plant
REPORT NO: 06-0294
Black
Intermittent Smoke Planned VOLUME
❑ ❑ 4,000 MSCF
TOTAL VOLUME 4,000 MSCF
Friday, June 30, 2006 Page 1 of 1
FACILITY: GC1
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
3. Flare/Relief Valve
4. Flare/Relief Valve
5. Flare/Relief Valve
6. Flare/Retief Valve
DATE: 22 Jun 2006
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke
00:00
02:25
12:50
15:38
16:52
21:50
01:30
04:15
14:10
16:35
18:40
22:20
1 Hrs 30Mins
1 Hrs 50Mins
1 Hrs 20Mins
0 Hrs 57Mins
1 Hrs 48Mins
0 Hrs 30 Mins
First Determination of Cause:
1. Continued - insufficient gas to load LP compressor. Assist gas added to prevent black smoke
2. Insufficient gas to load Sk -18 LP compressor. Assist gas added to prevent black smoke
3. reason unknown
4. Plant shutdown - insufficient gas to load LP compressor. Assist gas added to prevent black smoke
Action Taken to Stop Flaring:
1. Continued ramping up until compressors loaded
2. Continued ramping up until compressors loaded
3.
4.
Friday, June 30, 2006
REPORT NO:
BPXA FLARE REPORT
PRUDHOE BAY
❑
0
TOTAL VOLUME
06 -0295
Planned VOLUME
❑ 1,500 MSCF
❑ 1,146 MSCF
❑ , 556 MSCF
❑ 396 MSCF
❑ 750 MSCF
❑ 417 MSCF
4,765 MSCF
Page 1 of 1
FACILITY: GC1 DATE: 23 Jun 2006
REPORT NO: 06 -0299
BPXA FLARE REPORT
PRUDHOE BAY
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:00 13:08 13Hrs 8Mins W ❑ ❑ 6,567 MSCF
2. Flare/Relief Valve 16:39 17:00 0 Hrs 21 Mins ❑ ❑ ❑ 131 MSCF
TOTAL VOLUME 6,698 MSCF
First Determination of Cause:
1. Plant shut down and startup. Not enough gas for IP /LP compressors to operate.
2. Plant shut down and startup. Not enough gas for IP /LP compressors to operate.
Action Taken to Stop Flaring:
1. Continue to bring up rate to the point where the LP /IP compressors have enough gas to operate.
Opened flare valve oft V-136 to keep Clare clean.
2. Continue to bring up rate to the point where the LP /IP compressors have enough gas to operate.
Opened flare valve off V -136 to keep flare clean.
Friday, June 30, 2006 Page 1 of 1
FW: GPB Flaring
Subject: FW: GPB Flaring
From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com>
Date: Fri, 23 Jun 2006 18:37:03 -0800
To: steve_mcmains @admin.state.ak.us
CC: "Kurz, John" <jobn.kurz@BP.com>, "GPB, Environ TL" <GPBEnvironTL@BP.com >, "GPB,
Environ Advisor East" <GPBEnvironAdvisorEast@BP.com >, "Fiedler, Anne M"
<Anne.Fiedler@BP.com >, "Benson, Gary A" <Gary.Benson @BP.com >, "Pfeiffer, Jim A"
<Thu PfeifTer@BP.com >, "GPB, FS1 /S1Y %STP Area Mgc"; > <GPBFS1TL@BP.com >, "GPB, GPMA
Ai Mgrt<GPBGPMATI n BP.corn' , "GPB,'GC1 r MM gr ,„}-GPBGC1TL@BII.com*t
To: Steve McMains, AOGCC
steve_mcmains@admin.state.ak.us
907-793-1241, fax 907 - 276 -7542
From: Hal Tucker, Prod Optimization Team Leader (907 - 659 -4472)
Extended flaring events occurred at GPB in the last week. The events occurred at GC1 (6/21 -23),
GPMA (6/21 & 22), and FS1 (6/21).
The GC1 flare event began after a full plant shut down at (1830 6/21) caused by an automation glitch.
Due to the combination of low oil rates as the plant was coming back on and high ambient temperatures,
the IP and LP compressors failed to load up. A second automation glitch knocked the plant back down
at 2115 on 6/23. Flaring continued intermittently across both events until sufficient oil rate was brought
on to enable the LP and IP compressors to load up. Duration of intermittent flaring was 40 hours and 58
minutes, total volume flared was 15,323 MSCF.
Two extended flaring events occurred at GPMA. The first event was a shut down of the STV /IP
compressor 1801 due to bad exhaust stack temperature switch. Restart of 1801 was hampered due to a
bad fire eye. Duration of the event was 3 hours and 12 minutes of intermittent flaring. Total volume was
778 MSCF. A second event occurred at 1306 on June 22 when STV /IP compressor 1800 shut down due
to high discharge temperature which was a result of high ambient temperatures. 185 MSCF was flared
during the 61 minute intermittent event.
On June 21 at FS1, a planned depressuring of the A -HP separator, scrubber and liquid pot for blinding
occurred. Duration was 3 hours and 30 minutes, total volume flared was 128 MSCF.
If you require additional information, please don't hesitate to call me.
Hal Tucker
GPB Production Optimization Team Leader
bp Exploration AK, Inc
(907) 659 -4472
1 of 1 6/25/2006 9:1 I AM
12 Facility Number 2 Facility Name
3. Field
PBU - WOA
4 Operator
IBP
S Month/Year N Disposition
July -2006
0290000031 PBU GC 1
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pooi as • percent of
Total Volume.
8. 80M
0
Pool Nan*
Pool Code
Percent
7 Reinjected
0
PRUDHOE
640150
95.21%
LISBURNE
640144
0.21%
II Flared or vented 1 hour or less
678 1. 7
MIDNIGHT SUN
640158
0.60%
PT MCINTYRE
640180
3.98%
w Nee
9. Flared or vented more aten 1 hour kratr.)
6,676 v
BOREALIS
640130
0.00%
AURORA
640120
0.00%
10. Paw and Purge
23,405 1
11. Used for lease operations (specify in Remarks)
370,223
= i ' : .....
Authorization >1 hr
• -.
Safely
447‘
t
MCF
12. Other (see Mstruceom)
0
13. TOTAL VOLUME (ITEMS 5.12)
400,962
Lease Use
MCF
14. NGL Gas Equivalent
0
Conservation
MCF
15. Purchased gas
0
Waste.
MCF
18. Transferred Iran:
0
,'� (�(��(/J�� %J /1
`J —3 � (9
- Cun' issione Moo (9‘
�'/t�
17. Transferred rc: (Express as a negative a) CGF
- 24,011,380
7
18. Remarks. Block I I: Fuel Gas = 370,223 mscf and Assist Gas= 0 mscf
I hereby certify tat the foregoing is true and correct to the best of my knowledge.
/ lJ�
Signature (.J..,.w 4, rise Manager, Production Taxes and Royalty
Note: M volumes must be
corrected to pressure of 14.65 psla
and to a temperature of 60o F.
Authority 20 AAC25.235.
/
Printed Nam Bernard Name Be W. Hajny Pirate (907)554 -502e Ewe Si f Sic 6
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
J�
hour
1
'Unplanned Events Tess than or equal to 1
VOLUME
24
117
14
104
370
49
DATE
7/1/2006
7/4/2006
7/9/2006
7/11/2006
7/11/2006
7/14/2006
DATE TIME
7/1/2006 0802 -1308
7/15/2006 0035 -0610
DATE
DATE
7/15/2006
TIME
0255 -0330
1220 -1234
1810 -1820
0558 -0604
0840 -0900
0302 -0312
TOTAL
TOTAL
TIME
TOTAL
TIME
1225-2340
TOTAL
Assist
TOTAL FLARED VOLUME
678
5,046
0
1,630
TOTAL
Unplanned Events < 1 Hour 878
Unplanned Events> 1 Hour 5,048
Planned Events < 1 hour and not 0
exceeding 5,000 MCF
Planned Events > 1 hour or 1.830
exceeding 5,000 MCF
Pilot Purge
. 23,41161
0,
30,759
8P EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
July 2006
DESCRIPTION OF INCIDENT & CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
(Unplanned Events greater than 1 hour
VOLUME DESCRIPTION OF INCIDENT & CAUSE
2,338 See attachments
2,708
(Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
VOLUME _ DESCRIPTION OF INCIDENT & CAUSE
attachments
Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
VOLUME DESCRIPTION OF INCIDENT • CAUSE
1,630 See attachments
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
1
ACTION TAKEN TO ELIMNATE CAUSE , ._-
See attachments
1
ACTION TAKEN TO EUMINATE CAUSE
attachments
1
ACTON TAKEN TO EUMINATE CAUSE
See attachments
Page 1
8/9/ 2006
2.00 PM
FACILITY: GC1 DATE: 01 Jul 2006
REPORT NO: 06 -0314
BPXA FLARE REPORT
PRUDHOE BAY
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 02:55 03:30 OHrs 35Mins ❑ ❑ ❑ 24 MSCF
2. Flare/Relief Valve 08:02 13:08 5 Hrs 6Mins ❑ ❑ ❑ 2,338 MSCF
TOTAL VOLUME 2,362 MSCF
First Determination of Cause:
1. Due to PLC cable failure, in LPS section of plant. GC -1 and the Annex S/D.
2. GC -1 start -up following plant shutdown (PLC problem). Flared gas off V -136 until enough gas for
Skid 18 IP/LP compressors.
Action Taken to Stop Flaring:
1. LPS PLC cable repaired.
2. Finally had enough gas for Skid 18 IP /LP compressors, loaded IP /LP compressors.
Monday, July 31, 2006 Page 1 of 1
1
C>
FACILITY: GC1 DATE: 15 JUI 2006
BPXA FLARE REPORT
PRUDHOE BAY
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:35 06:10 5Hrs 25Mins ® ❑ ❑ 2,708 MSCF
2. Flare/Relief Valve 12:25 23:40 11 Hrs 15Mins ❑ ❑ ® 1,630 MSCF
TOTAL VOLUME 4,338 MSCF
First Determination of Cause:
1. Sk -18 LP compressor surging because of a problem associated with reducing rates for ESD test.
2. Depressuring well pad flowlines for shut down work
Action Taken to Stop Flaring:
1. continuous tweeking of micon to minimize flaring.
2. Still depressuring
REPORT NO: 06-0330
Monday, July 31, 2006 Page 1 of 1
FW: GPB Flaring
To: Steve McMains, AOGCC
steve_mcmains@admin.state.ak.us
907 - 793 -1241, fax 907 - 276 -7542
From: Hal Tucker, Prod Optimization Team Leader (907 - 659 -4472)
If you require additional information, please don't hesitate to call me.
Hal Tucker
GPB Production Optimization Team Leader
bp Exploration AK, Inc
(907) 659-4472
Subject: FW: GPB Flaring
From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com>
Date: Tue, 18 Jul 2006 09:56:52 - 0800
To: steve_mcmains @admin.state.ak.us
CC: "Kurz, John" <john.kurzi@BP.com >, "GPB, Environ TL" <GPBEnvironTL@BP.com>, "GPB,
Environ Advisor East" <GPBEnvironAdvisorEast@BP.coin>, "GPB, Environ Advisor West"
GPBEnvimnAdvisorWest@BP.com>, "Fiedler, Anne M" <Anne.Fiedler@BP.com >, "Benson, Gary
A" <Gary.Benson@BP.com>, "Pfeiffer, Jim A" <Jim.Pfeiffer@BP.com >, "GPB, GC1 Area Mgr" .. ;
ftaBGCITL.BP
Extended flaring events occurred at GC1 beginning July 15 at 00:35. In preparation for the GC1
turn - around, rate was reduced to perform a full plant ESD test. With the reduced rate, there was
insufficient oil rate to allow the IP /LP compressors to bite. Duration of the event was 5 hours and 25
minutes of intermittent flaring, total flared volume was 2,708 MSCF. The event ended when the ESD test
was performed. Following the ESD test, the plant and associated equipment required depressuring for
safe -out activities. Depressuring for safe -outs continued for 11 hours and 15 minutes, with a total
volume of 1,630 MSCF.
1 of 1 7/18/2006 10:44 AM
1 Facilir Number
0290000031
2 Facih Name
N
� PBU GC 1
3. FiaW
4 razor
Ope
BP
5. MontlWSar d DispoeNlon
August - 2006
PBU - WOA
Disposition
Volume MCF
/
✓
20. For production from mutllple pools, list conmbution of each pod as a pemea of
Total Volume
6. Stxd
0
Pod Name
Pad Code
Percent
T Reinjected
0
PRUDHOE
640150
99.62%
LISBURNE
640144
0.07%
8. flared or vented llttxdorless
2,513
MIDNIGHT SUN
640158
0.23%
PT MCINTYRE
640180
0.08%
1 hour (see krsv.)
7500
BOREALIS
640130
0.00%
d
9. Flared or vented more than
AURORA
640120
0.00%
10. Pilot and Purge
41 832
11. Used for lease operations (specify in Remarks)
527,442
12. Other (see instruction)
0
Authorization >1 hr
Se
Safety
7 500
MCF
13. TOTAL VOLUME (fTEMS 8-12)
579,287
Lease Use
MCF
14. NGL Gas Equivalent
0
Conservation
MCF
15. Pvdtased gas
0
Waste:
MCF
16. Transferred from:
0
_ //_ /�
/ miaar" Date
17. Transferred b: (E�ress as a mitigative e) CGF
- 45,729,756
18. Remarks Block 11: Fuel Gas = 527.442 mscf and Assist Gas c 0 mscf
I hereby oetily
Signs ,-,
is true a
best of my knowledge.
Tate Manager, Production Taxes and Royalty
Note: All volumes must be
corrected to pressure of 14.65 psis
and to a temperature of 60o F.
Authority 20 AAC25.235.
Printed Name Berner W. Rainy
G
Phone (907)564 -5028 Date f �f U�
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
hour
1
'Unplanned Events less than or equal to 1
TIME VOLUME
1108-1115
1335 -1504
0900 -1000
0001 -0026
0253 - 0301
1030
DATE
8/6/2006
817/2006
8/9/2006
8/11/2006
8/16/2006
8/19/2006
TOTAL
75
297
1,000
2
1,111
28
2,513
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
August 2006
DESCRIPTION OF INCIDENT 8 CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
1
Unplanned Events greater than 1 hour
VOLUME DESCRIPTION OF INCIDENT & CAUSE
7,260 See attachments
30
210
DATE
8/4/2006
8/10/2006
8/11/2006
TIME
0000 -1015
1652 -2359
0730-0911
TOTAL
7.500
1
'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
VOLUME DESCRIPTION OF INCIDENT 8 CAUSE
See attachments
DATE
TIME
TOTAL
1
`Planned Events Exceeding 1 Hour OR Exceeding 5000 Mot
TIME .. .., VOLUME DESCRIPTION OF INCIDENT & CAUSE -, M1 ,,.._ ACTION TAKEN TO ELIMINATE CAUSE,,,,,,, .,,,,,,,,,, r ,
See attachments
TOTAL
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events c 1 four and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
0
0
TOTAL
2,513
7,500
0
0
MIMI 41,832
O
51,845
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
ACTION TAKEN TO ELIMINATE CAUSE,
See attachments
ACTION TAKEN TO EUMINATE CAUSE
attachments
Pega
1/8/2008
4:57 PM
t�
FACILITY: GC1 DATE: 04 Aug 2006
First Determination of Cause:
1. GC1 start -up after turnaround
Action Taken to Stop Flaring:
1. Started K -7001
BPXA FLARE REPORT
PRUDHOE BAY
REPORT NO: 06 -0376
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:00 10:15 10Hrs 15Mins [ ❑ ❑ 7,260 MSCF
TOTAL VOLUME 7,260 MSCF
Monday, August 28, 2006 Page 1 of 1
FACILITY: GC1 DATE: 10 Aug 2006
BPXA FLARE REPORT
PRUDHOE BAY
REPORT NO: 06 -0400
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 16:52 23:59 71-Irs 7Mins Q ❑ ❑ 30 MSCF
TOTAL VOLUME 30 MSCF
First Determination of Cause:
1. Depressure PM2 to GC -1 line due to road sluffing off and Drilling Rig almost falling onto line.
Depressured line to safely remove Rig from location near line and back onto firm road bed.
Action Taken to Stop Flaring:
1. Once PM2 line was depressured flare valves wer closed.
Monday, August 28, 2006 Page 1 of 1
Cis
FACILITY: GC1 DATE: 11 Aug 2006
2. Depressured line to 49# and proceeded to inspect.
REPORT NO: 06-0401
BPXA FLARE REPORT
PRUDHOE BAY
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:01 00:26 0 Hrs 25Mins ❑i ❑ ❑ 2 MSCF
2. Flare/Relief Valve 07:30 09:11 1 Hrs 41 Mins l] ❑ ❑ 210 MSCF
TOTAL VOLUME 212 MSCF
First Determination of Cause:
1. Depressure PM2 to GC -1 line due to road sluffing off and Drilling Rig almost falling onto line.
Depressured line to safely remove Rig from location near line and back onto firm road bed.
2. Operator found Point Mac line off of VSM, Depressured line to B -S /C that is out of service.
Action Taken to Stop Flaring:
1. Stopped depressuring tine when it was at a safe pressure to move rig back onto firm section of road.
Monday, August 28, 2006 Page 1 of 1
1. Fatuity Number
0290000031
2. Facility Name
PBU GC 1
3 Field
PBU - WOA
14. Operator
IBP
15. MaeM/Nr of Disposition
I September -2006
Disposition
Volume MCF
20. For production from multiple pools. list contribution of each Paean • pematt of
Total Volume
8. Sold
0
Pod Name
Pool Code
Penent
0
PRUDHOE
640150
96.02%
LISBURNE
640144
0.164E
e. Flared a vented 1 (tote a bus
7 596
MIDNIGHT SUN
640158
0.28%
PT MCINTYRE
640180
3.54%
m
9. Flared or vented more an 1 hour (sea Instr.)
0
BOREALIS
640130
0.00%
AURORA
640120
0.00%
10 Pad and Purge
41,329
11. Used for lease operations (specify in Remarks)
712,676
12. Other (see instructions)
0
Authorization >7 hr
Safety
MCF
13. TOTAL VOLUME (ITEMS 6
761,601
Lease Uee
MCF
14. NM Gas Equivalent
0
Conservation
' ,
is. Purchased gas
0
Waste:
MCF
16. Transferred ham:
0
Commfaeioner Date
17. Transferred to: (Express as a negative e) CGF
- 70,854,548
18. Remarks: Block t 1: Fuel Gas = 712,676 mscf and Assist Gas = 0 mscf
I hereby certify that the °going is true a ad to the best of my knowledge
Signature J Tine Manager, Production Taxes and Royalty
Note: All volumes must be
corrected to pressure of 14.65 pule
and to a temperature of 60o F.
Authority 20 AAC25.235.
Printed Name Bernard W. Hajny Phone (907)564 -50213 Dare %Q //-o6
1
Forrn 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
J
I
'Unplanned Events less than or equal to 1 hour
VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE
347 Not required tor unplanned events which Not required for unplanned events which
486 are less than or equal to 1 hour are less than or equal to 1 hour
DATE TIME
9/6/2006 1213 -1218
9/8/2006 0019 -0026
9/9/2006 1624 -1632
9/9/2006 2023 -2029
9/9/2006 2207-2214
9/10/2006 2250 - 2257
9/11/2006 0029 -0036
9/11/2006 0050 - 0057
9/15/2006 0655 -0720
9/15/2006 0738 -0746
9/15/2006 0937 -0943
9/24/2006 2118-2124
9/27/2006 2029 -2040
9/29/2006 1617 -1651
TOTAL
'Unplanned Events greater than 1 hour
1
TIME VOLUME._,,. DESCRIPTION OF INCDENT & CAUSE
See attachments
TOTAL
556
417
486
486
486
486
1,736
556
417
417
130
590
7,596
0
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
September 2006
1
Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
VOLUME .. DESCRIPTION OF INCIDENT &
See attachments
DATE
TIME
TOTAL
0
1
(Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
VOLUME DESCRIPTION OF INCIDENT & CAUSE
See anachments
DATE
TIME
TOTAL
Unplanned Events <1 Hour
Unplanned Events> 1 Hour
Plamed Events <1 hour and not
exceeding 5,000 MCF
Palmed Events > 1 (sour Or
exceedtg 5600 MCF
Pod Purge
Assist
TOTAL FLARED VOLUME
0
TOTAL
_._. -.. 7,596
0
0
0
WIPS 4t,32S
48,925
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE .
..........
See attachments
P50e
1011/2008
1:34 PM
GC2 Flaring
Subject: GC2 Flaring
From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com>
Date: Sun, 20 Aug 2006 16:45:35 -0800
To: steve_mcmains @admin.state.ak.us
To: Steve McMains, AOGCC
steve mcmains @admin.state.ak.us
907 - 793 -1241, fax 907 - 276 -7542
From: Hal Tucker, Prod Optimization Team Leader (907 - 659-4472)
1) shut in all HP production to reduce 2nd stage gas volume
2) shut in produced water sweep gas to reduce 3rd stage gas volumes
3) added overhaul resources to ensure 24 hour per day maintenance on K207
4) leaving LPS production on line to reduce restart duration
total duration and total flared volume once K207 is back on line and loaded.
If you require additional information, please don't hesitate to call me.
Hal Tucker
GPB Production Optimization Team Leader
CC: "GPB, Environ TL" <GPBEnvironTL@BP.com>, "GPB, Environ Advisor East" < GPBEnvironAdvisorEast@BP.com >, "GPB. Environ,
Advisor West" <GPBEnvironAdvisorWest @BP.com >, "Fiedler, Anne M" <Anne,Fiedler@BP.com >, "Benson, Gary A"
<Gary.Benson @BP.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer @BP.com >, "GPB, GC2 Area Mgr" <GPBGC2TL@BP.com >, "GPB, GC2 OTL"
<gpbec2otl @BP.com >, "Kurz, John" <john.kurz@BP.com >, "GPB, Optimization Engr" <GPBOptimizationEngn@BP.cone>„ "GPB, GC2
Plant Engineer" <GPBGC2P1antEngineer@BP.com>,," GPB, GC2 AMS "<GPBGC2AMS@BP. onnt? -'' r u
-50 - 60 mbd of oil is required to provide enough 2nd and 3rd stage gas to load up the IP and LP machines
LPS production is predominately gas lifted and takes more time to kick these wells off
Shutting in LPS production will require restarting K7000 and K7001 (the copus starting motor sends gas to flare)
An extended flaring event is in progress at GC2. IP compressor K207 experienced a seal leak on Aug 19 and requires a new seal. The spare IP j
machine (K208) has a short in the motor, requiring the motor to be replaced and therefore is unavailable at this time. Due to the current
circumstances at GPB, we have determined that leaving the plant partially running during the K207 maintenance is the most prudent course of
action at this time. We have taken the following actions to minimize the total flare volume:
4$ K 70F
We are anticipating completion of the work and K207 restart late Tuesday - early Wednesday, Aug 23. We will send you a follow up note with
1 of 2 8212006 7 :55 AM
GC2 Flaring
2 of 2
bp Exploration AK, Inc
(907) 659-4472
8/21/2006 7:55 AM
1 Facility Number
0290000031
2. Facility Name
PBU GC 1
3 Field
PBU • WOA
4. Operator 5. Month/Year d Diepoelton
BP October -2006
Disposition
Volume MCF
20. For production from multiple pods. fist contribution of nob pool as • percent a
Tool Yawn.
8. Sold
0
Pool Name
Pod Code
Percent
T ho
0
PRUDHOE
640150
95.43%
LISBURNE
640144
0.16%
8. Flared or vented 1 hour or
4,514
MIDNIGHT SUN
640158
0.69%
PT MCINTYRE
640180
3.72%
9. Fed or vented more than 1 hour (see katr.)
Flared
45,698 ,/
BOREALIS
640130
0.0054
AURORA
640120
0.0096
10. Pad and Purge
40,941
11. Used for lease aperatbm (specify in Remain)
783,245
12. Other (see Instructions)
0
Authorization ,, ht
safety
4-5, l
X9
MCF
13. TOTAL VOLUME (ITEMS 5.12)
874,398
tease Use
MCF
1s. NOL Gas Equivalent
0
Conservation
MCF
15. Purchased gas
0
Waste:
MCF
18. Transferred from:
0
��� 1 '► ( �` / ' / /// / �� /� DL
Com sslorar /t -fS Deb
17. Transferred to: (Express u a negative e) CGF
- 58,076,645
18. Remarks: Block 11: Fuel Gas = 783,245 inset and Assist Gas =0 mscf
I hereby certify that the foregoing S true and Z /,y/J�t1e best a my knowledge.
- / /��� /
Signature i�I rroe Manager, Production Taxes and Royalty
Note: All pressure f 14.65 5
c orrected to praswro of 14.65 pale be
and to a temperature of 60o F.
Authorttv 20 AAC25.235.
.
//--
Punted Name Bemard W. Hajny Phone (907')584 -5028 oat.* Cp ��eL'
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
�R-
1
'Unplanned Events Tess than or equal to 1 hour
VOLUME DESCRIPTION OF INCIDENT & CAUSE
222 Not required for unplanned events which
188 are less than or equal to 1 hour
258
1,111
903
764
24
3
417
208
208
208
DATE
10/12/2006
10/13/2006
10/13/2006
10/15/2006
10/15/2006
10/18/2006
10/20/2006
10/23/2006
10/26/2006
10/26/2006
10/27/2006
10/30/2006
TIME
1128 -1200
0001 -0028
1509 -1540
1650 -1706
1828 -1841
1716 -1727
0227 -0232
0929 -0934
1235 -1247
1235 -1247
1328 -1334
1702 -1708
TOTAL
4,514
1
'Unplanned Events greater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
10/10/2006 0300 -0716 33,244 See attachments
10/13/2006 1210 -1454 655
10/13/2006 1600 -2400 1,667
10/14/2006 0001 -2250 9,507
10/30/2006 0918 -1058 625
DATE
TOTAL.
TIME
TOTAL
45,698
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
October 2006
'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mc1
VOLUME ,n;4 DESCRIPTION OF INCIDENT & CAUSE
See attachments
0
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are Tess than or equal to 1 hour
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
r ACTION TAKEN TO ELIMINATE CAUSE,,, „,. ,,,, - „.,
See attachments
Page 1
1
11/9/2006
11:18 AM
Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
DESCRIPTION OF INCIDENT & CAUSE , n n ACTION TAKEN TO ELIMINATE CAUSE ,. ,
See attachments See attachments
DATE. TIME
TOTAL
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
VOLUME
0
TOTAL
4,514
45,698
0
0
1111111
91,153
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
October 2006
Page 2
11/9/2006
11:18 AM
06-87 Flare Relief
Flare Start Date 10/1/2006
Flare End Date 10/31/2006
Time Of Flaring
Report Number Date Start Time
Volume (MSCF)
System
Generated 11/2/2006
GC1 Flare Report
Stop Time Duration Intermittent
Black Smoke
Total Volume
MSCF)
50212
Planned Reported By
06.76 Flare Relief 10/10/2006 3:00:00 AM 7:16:00 AM 2 minutes No No No BP1 \CLARKTL
Determination Cause GC Shut down and lost air pressure due to CPS power failure.
Action Taken Shut dovmatiseepa'-
-�- Daily Volume (MSCF) 33244
06-85 Flare Relief 10/12/2008 11:28:00 PM 12:00:00 AM 32 minutes No No No 8P1\MESSERTD 222
Determination Cause Equilizing pressure around perimeters for starting GC -1.
Action Taken No response taken as this was deemed to be of short duration.
Daily Volume (MSCF) 222
06-87 Flare Relief 10/13/2006 12:01:00 AM 12:28:00 AM 27 minutes No No No BP7 \MESSERTD 188
Determination Cause Equalizing pressure around perimeters for starting GC -1.
Action Taken No response taken as this was deemed to be of start duration.
10/13/2006 12:10:00 PM 2:54:00 PM 164 minutes No No No BP1\MESSERTD 888
Determination Cause Equilizing pressure around perimeters for starting GC -1.
Action Taken GC Start up.
06-87 Flare Retlet -- 10/13/2008 3:09:00 PM- - 3:40:00 PM -- 31 minutes No No No BP1 \MESSERTD 258
Determination Cause Starting K - 7000
Action Taken No response taken as this was deemed to be of short duration.
Page 2 of 5
33244 �
Flare Start Date 10/1/2006
Flare End Date 10/31/2006 - _
06.87— Flare Relief 10/13/2006 4:00:00 PM 12:00:00 AM 480 minutes- No No No BPI\MESSERTD
Determination Cause Plant start up, not enough gas to run LP and IP compressors.
Action Taken Continued to bring on rates for compressors.
06.93 Flare Reliet 10/14/2006 12:01:00 AM 10:50:00 PM 1369 minutes No No No BPI\ MESSERTD
Determination Cause GC -1 On start up, problems with Odd reboiler and Annex reboller, can
not produce enough gas to operate LP and IP gas compressors
Action Taken
Hold cunent gas rates and let operations/maint. trouble shoot
reboders and LP and IP compressors.
06 Flare Relief 10/15/2006 4:50:00 PM 5:08:00 PM 18 minutes No No No BP1\MESSERTD
Determination Cause The Carry Over Prevention System initiated LPS flare valve opening to
prevent contactor flooding/TEG carryover when gas rates exceeded
the OP on contactor.
Action Taken
Action Taken
06 Flare Relief 10/18/2006 5:16:00 PM 5:27:00 PM 11 minutes No
Action Taken
WOA reduced production rates and shut -in 3 wells equaling 50
mmsdd. Welts were shut-in or choked back starting at 1851 hours.
06-98 Flare Relief 10/15/2006 6:28:00 PM 6:41:00 PM 13 minutes No No No 8P1 \MESSERTD
Determination Cause The Carry Over Prevention System initiated LPS flare valve opening to
prevent contactor flooding/TEG carryover when gas rates exceeded
the DP on contactor.
WOA reduced production rates and shut -in 3 wells equaling 25
mmacfd. Wells were shut -in or Baked beck starting at 1829 hours.
No No BP1\MOMAMD
Determination Cause The Carry Over Prevention System initiated LPS flare valve opening to
prevent contactor flooding/TEG carryover when gas rates exceeded
the 1000 mmsdd operability limit.
PCC moved rate to Annex Odd rebolier Is showing a Hi DP at 1000
mmacfd .
1867
Daily Volume (MSCF) 2768
9507
Daily Volume (MSCF) 9507
903
Daily Volume (MSCF) 2014
784
Generated 11/2/2008 Page 3 of 5
Flare Start Date 10/1/2006
Flare End Date 10/31/2006
6-c
06 Flare Relief 10(30/2006 9:18:00 AM 10:58:00 AM 100m61utes?, No No No 5P1UACKSOWM
Determination Cause IP compressors lost suction and vented to flare while depressuring
Test Separator for LP testing
Action Taken
Finished depressuring
06-130 Pare Relief 10/30/2006 5:02:00 PM 5:08:00 PM 6 minutes No No No BPIUACKSOWM
Determination Cause The Carry Over Prevention System Initiated LPS flare valve opening to
prevent contactor flooding/TEG carryover when gas rates exceeded
the 1140 mmsctd operability limit due to the LPS compressor recycle
Action Taken valve sticking.
LPS compressor repaired and stablized rates
Daily e (MSCF) 206
825
208
Daily Volume (MSCF) 833
Total Volume 50212
MSCF)
Generated 1 1/1!2008 Page 5 of 5
It G. ( G:u flaring InciJcm
Subject: RE: GPB Gas Flaring Incident
From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com>
Date: Fri, 13 Oct 2006 13:09:00 - 0800
To: "sieve mcmains @admin.state.ak.us" <' sieve _mcmains@admin.state.ak.us'>, "GPB, Environ TL" <GPBEnvironTL@BP.com>, "GPB,
Environ Advisor East" <GPBEnvironAdvisorEast @BP.com >, "Fiedler, Anne M" <Anne.Fiedler@BP.com >, "Benson, Gary A"
<Gary.Benson @BP.com >, "Pfeiffer, Jim A" <Jim.Pfeifer @BP.com >, "GPB, FS3 Area Mgr" <GPBFS3TL@BP.com >, "GPB, FS3 Ops
Lead" <GPBFS3OpsLead @BP.com >, "GPB, GC1 Area Mgr" <GPBGCITL@BP.com >, "GPB, GC1 Ops Lead"
<GPBGCI OpsLead @BP.com >, "GPB, Environ Advisor West" <GPBEnvironAdvisorWest @BP.com >, "GPB, FS1 /SIP /STP Area Mgr"
<GPBFSITL@BP.com >, "GPB, FS1 Ops Lead" <GPBFS1OpsLead @BP.com >, "GPB, Gas Plants Area Mgr"
<GPBGasPlantsTL@BP.com>, "GPB, CGF Ops Lead" <GPBCGFOpsLead@BP.com>
CC: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com >; •
To: Steve McMains, AOGCC
steve_mcmains@admin.state.ak.us
907 - 793 -1241, fax 907 - 276 -7542
From: Dwight Warner, GPB Field Optimization Engineer
for Hal Tucker /Mike Bolkovatz GPB Prod Optimization Team Leaders
Flaring events related to field wide shutdown from power outage.
• CGF event occurred on October 10th starting at 08:30 and lasted 1 hr 0 mins, total volume flared was 1005
MSCF. P -203 Res gas to flare header.
• FS1 event occurred on October 10th starting at 02:53 and lasted 21 hrs 6 mins, total volume flared was 7,190
MSCF. 1801 compressor unloading most of the day.
• FS3 event occurred on October 10th starting at 02:50 and lasted 2 hrs 27 mins, total volume flared was 43,942
MSCF. Field wide power outage lost 1802/03 tandem compressors and 1804 TN.
• GC1 event occurred on October 10th starting at 03:00 and lasted 4 hr 16 mins, total volume flared was 33,244
MSCF. GC shut down and lost air pressure due to power outage.
• FS1 event occurred on October 11th starting at 00:01 and lasted 23 hrs 58 mins, total volume flared was 7,150
I of 2 10/13/2006 1:23 PI
RE: 61 Gas Flaring Incident
201
MSCF. 1801 tandem compressor unloading due to low rates.
• FS3 event occurred on October 11th starting at 00:01 and lasted 4 hrs 6 mins, total volume flared was 741
MSCF. 1802 tandem compressor controls problem where it would not load.
• CGF event occurred on October 12th starting at 17:07 and lasted 4 hrs 38 mins, total volume flared was 86
MSCF. Intermittent flaring of MI as facility was restarted after complete field power outage.
• FS1 event occurred on October 12th starting at 00:01 and tasted 13 hrs 4 mins, total volume flared was 3,873
MSCF. 1801 tandem compressor unloading due to low gas rates.
If you require additional information, please don't hesitate to call me.
Dwight Warner
GPB Field Optimization Engineer
(907) 659 -4382
for
Hal Tucker /Mike Bolkovatz
GPB Prod Optimization Team Leader
(907)- 659 - 4472/5566
10/13/2006 123 Pt
ti I'Il ( las Flaring Incidents
Subject: GPB Gas Flaring Incidents
From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com>
Date: Thu, 19 Oct 2006 13:34:57 -0800
To: "steve_mcmains@admin.state.ak.us" <'steve _mcmains @admin.state.ak.us' >, "GPB, Environ TL" <GPBEnvironTL@BP.com >, "Fiedler,
Anne M" <Anne.Fiedler @BP.com >, "Benson, Gary A" <Gary.Benson @BP.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer@BP.com >, "GPB, GC1
Area Mgr" <GPBGC LTL @BP.com >, "GPB, GC3 Area Mgr" <GPBGC3TL@BP.com >, "GPB, Environ Advisor West"
<GPBEnvironAdvisorWest BP.com>
To: Steve McMains. AOGCC
steve_mcmains @admin.state ak us
907 - 793 -1241, fax 907 - 276 -7542
From: Michael Bolkovatz GPB Prod Optimization Team Leader
• GC3 event occurred on October 13th starting at 11:47 and lasted
MSCF. Depressured X Pad for LDF repairs.
• GC3 event occurred on October 13th starting at 13:24 and lasted
MSCF. Plant start up, not enough gas to run LP and IP compress
• GC1 event occurred on October 13th starting at 12:10 and lasted
MSCF. Equalizing pressure around perimeter valves for starting G
• GC1 event occurred on October 13th starting at 16:00 and lasted
MSCF. Plant start up, not enough gas to run LP and IP compress
• GC 1 event occurred on October 14th starting at 00:00 and lasted
MSCF. Plant start up, not enough gas to run LP and IP compress
• GC1 event occurred on October 14th starting at 12:10 and lasted
MSCF. Equalizing pressure around perimeter valves for starting G
• GC3 event occurred on October 15th starting at 21:00 and lasted
MSCF. Depressured X Pad for LDF repairs.
1 hr 6 mins, total volume flared was 300
7 hrs 18 mins, total volume flared was 9,000
ors.
2 hrs 44 mins, total volume flared was 655
C -1.
8 hrs 0 mins, total volume flared was 1,667
ors.
22 hrs 49 mins, total volume flared was 9,507
ors.
2 hrs 44 mins, total volume flared was 655
C -1.
3 hr 0 mins, total volume flared was 300
1 of 2 10119/2006 2:36 PM
Gay flaring Incidents
2of2
If you require additional information, please don't hesitate to call.
Michael Bolkovatz
GPB Production Optimization TL
(907) 659 - 4472/5566
10/19/2006 2:36 PN
Facility Number
0290000031
I1. 2. Facility Facility Name
PBU GC 1
3. FFink, f
PBU - WOA
4. OpBoperator operator
BP
5. Ma18WNr of Disposition
November - 2006
Disposition
Volume MCF
20. For production from multiple pods, list Contribution at each pool as a percent of
Total Volume
e. Sod
0
Pod Name
Pod Code
Percent
7 Reinjected
0
PRUDHOE
640150
95.65%
LISBURNE
640144
0.21%
8. Flared or vented 1 tour or less
4,467
MIDNIGHT SUN
640158
0.51%
PT MCINTYRE
640180
3.63%
1 hour (see Instr.)
0
BOREALIS
640130
0.00%
9 Flared or vented more than
AURORA
640120
0.00%
le Pilot and Purge
38,233
11. Used for lease operations (specify in Remarks)
878,846
12. Other (see instructions)
0
Aotflodntion >1 hr.
Safely
MCF
13. TOTAL VOLUME (ITEMS 8.12)
921,546
Lease Use
MCF
14. NGL Gas Equivalent
0
Conservation
MCF
15. Ptrchased gas
0
Waste:
MCF
18. Transferred from:
0
Commissioner ale
17. Transferred to: (Express as a negative s) CGF
- 53,431,326
B. Remarks: Block 11: Fuel Gas = SJS S46 mscf and Assist Gas = 0 rtscf
I hereby certify that the toregoino b true and carne
Signature
the hest of my knovAedge.
Title Manager, Production Taxes and Royalty
Note: All volumes must be
corrected to pressure of 14.65 pale
and to a
Authority 20ro F.
AAC25.235.
Printed Name Bemard
W. Hajny
Phone (907)564-5028 Dare /0 — /- 5-- "C " &'
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
SNP
DATE
11/1/2006
11/1/2006
11/9/2006
11/17/2006
11/17/2006
11/17/2006
11/22/2006
11/22/2006
11/23/2006
11/30/2006
0556 -0641
1142-1155
1812 -1821
2343 -2350
2142-2152
TOTAL
215
903
69
53
694
4,467
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
November 2006
!Unplanned
Events less than or equal to 1 hour
TIME � VOLUME DESCRIPTION OF INCIDENT & CAUSE
1534 -1548 972 Not required for unplanned events which
1608 -1617 625 are less than or equal to 1 hour
0858 -0904 417
0240-0304 200
0350-0436 319
1
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
(Unplanned Events greater than 1 hour
1
, DATE
TIME: VOLUME DESCRIPTION OF INCIDENT & CAUSE. ACTION TAKEN TO EUMINATE CAUSE
See attachments See attachments
TOTAL
0
!Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
DATE : - ..,� . TIME �__ VOLUME,_ DESCRIPTION OF INCIDENT & CAUSE . g , g , s , ACTION TAKEN TO ELIMINATE CAUSE i
See attachments See attachments
TOTAL
0
(Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf
1
DATE f , -u •, TIME . < , VOLUME_ DESCRIPTION OF INCIDENT A CAUSE , - - -, ACTION TAKEN TO EUMINATE CAUSE @�,,,.,,
See attachments See attachments
TOTAL
Unplanned Events c 1 Hour
Unplanned Events> 1 Hour
Planned Events c 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Piot Purge
Assist
TOTAL FLARED VOLUME
0
TOTAL
4,467
0
0
0
SSW
42
Page 1
12/10/2006
4:37 PM
Facility Number
0290000031
11. 2. Facility Noma
PBU GC 1
3. Field
PBU - WOA
a_ Operator
BP
5. MonthN ar d Oispositlm
December - 2006
Disposition
Volume MCF
✓
J
20. For production from multiple pods, flat contribution of each pool as a percent of
Total Volume
6. Sold
0
Pod Name
Pool Code
Percent
7. Reinpicted
0
PRUDHOE
840150
94.65%
LISBURNE
640144
0.22%
s. Flared or vented lhour or less
13,500 „f'
MIDNIGHT SUN
640158
0.76%
PT MCINTYRE
640180
4.37%
9. Flared or vented more than 1 dour (see Intr.)
667
BOREALIS
640130
0.00%
AURORA
640120
0.00%
10. Wdand Purge
39,567 ,/
1 t. Used for leasee operations (specify In Remarks)
959,769
12. oe,er lase lnetiuclloru)
0
Authorization >1 hr
Safety
b ��
MCF
13. TOTAL VOLUME (ITEMS 612)
1,013,503
Lease Use
MCF
14. NGL Gas Equivalent
0
Conservation
MCF
IS Purchased gas
0
Waste
MCF
t6. TmetMled from:
0
Co�✓ ,2�5-07
�f; e Q
c / ' / ' , ^�'J Date
17. Transferred to: (Ewress as a negative a) CGF
- 71,928,228
1e. Remarsa: Black 11: Fuel Gas = 959,769 msc( and Assist Gas = 0 mscf
loaf the fue the • d knowledge.
1 hereby certify that n c my
Sipr arse 4L....... � nue Manager, Production Taxes and Royalty
Note: All volumes must be
corrected to pressure of 14.65 psis
and to a temperature of 60o F.
Authority 20 AAC25.235.
Printed Name Bemard W. Hajny Phone (907).564-5026 Dare //S --d?
4
Form 10-422 Rev. 1/2004
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Submit in Duplicate
(Unplanned Events Tess than or equal to 1 hour
1
DATE
12/3/2006
12/8/2006
12/16/2006
12/17/2006
12/25/2006
TIME
1603 -1614
1357 -1408
2321 -2334
1606 -1640
0858 -0909
TOTAL
VOLUME DESCRIPTION OF INCIDENT & CAUSE _
764 Not required for unplanned events which
764 are less than or equal to 1 hour
90
11,806
76
13,500
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - GC -1
GAS FLARING INCIDENT REPORT
December 2006
1
(Unplanned Events greater than 1 hour
VOLUME DESCRIPTION OF INCIDENT & CAUSE
667 See attachments
DATE TIME
12/30/2006 0326 -0726
TOTAL
667
, ACTION TAKEN TO EUMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
ACTION TAKEN TO EUMINATE CAUSE..,,. ,
See attachments
1
(Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf
TIME.....,.,. VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE lonsgarm
See attachments See attachments
DATE
TOTAL
..sz DATE TIME
TOTAL
Unplanned Events < 1 Hour
Unplanned Events > 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events > 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME
0
(Planned Events Exceeding 1 Hour OR Exceeding 5000 Mef
1
VOLUME DESCRIPTION OF INCIDENT & CAUSE
See attachments
0
xm TOTAL
13,500
687
0
0
39,567;
0
53.734
ACTION TAKEN TO EUMNATE CAUSE ...�...,«
See attachments
Page 1
1/12/2007
10:24 AM
Flare Start Date 12/1/2006
Flare End Date 12/31/2006
GC1 Flare Report
Time Of Flaring
Report Number Date Start Time Stop Time Duration Intermittent / Black Smoke / Planned Reported By Volume (MSCF)
06228 Flare Relief 12/30/2006 328:00 AM 7:26:00 AM 240 minutes No No No BP1\CLARKTL 667
Determination Cause Problem associated with vent valve on X•106.
Action Taken Flaring was permitted to continue while GC operations personnel
attempted to reseat vent valve.
GPB Gas Flaring Incident
Subject: GPB Gas Flaring Incident
From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com>
Date: Sun, 31 Dec 2006 13:28:49 -0900
To: stcve_mcmains @adnin.state.ak.us
CC: "GPB, Environ TL" <GPBEnvironTL @BP.com >, "GPB, Environ Advisor West"
<GPBEnvironAdvisorWest@BP.com >, "Fiedler, Anne M" <Anne.Fiedler@BP.com >, "Benson, Gary
A" <Gary.Benson @BP.com>, "Pfeiffer, Jim A" <Jim.Pfeiffer@BP.com >, "GPB, FS2/COTU Area ?a�
Mgt" GPBFS2TL@BP.cotrt > „b
To: Steve McMains, AOGCC
steve mcmains @admin.state.ak.us
907 - 793 -1241, fax 907- 276 -7542
From: Dwight Warner, GPB Field Optimization Engineer for
Hal Tucker, GPB Prod Optimization Team Leader
An extended flaring event occurred at GPB on December 30, 2006.
GC1 compressor K -106 flared due to a problem with the vent valve. Flaring
occurred while operations reseated the valve. Flaring occurred from 0326 to
0726 (240 minutes) and a total of 667 MSCF was flared.
If you require additional information, please don't hesitate to call me.
Dwight Warner, GPB Field Optimization Engineer