ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 01/2002
Disposition Volume MCF*
1. Sold 2,155,810
2. Reinjected 218,566,695
/'
3. Flared or vented less than 1 hour. 1,079
4. Flared or vented greater than 1 hour 186 ~
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 33,018
6. Used for lease operations Fuel 5,665,754
Assist 0
7. Other Lift Gas, Off Field 0
,/
TOTAL items 1 - 7 226,422,542
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 245,306,770
11. Transferred to: CGF 20,942,789
Remarks:
I hereby cer; rr t~ foregoing i~:rue and correct to the best of my knowledge.
Signature: . 1 ~ .... " Title: SUPERVISOR
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
)~~
MCF
3. Conserv. Purposes
MCF
[p;~ {Mivl !fw~ 3J~ /o:r
Commissi~er Date
~ L~ L
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
Form 10-422 (Revised 4/95)
SP EXPLORATION (ALASKA) INC.
PRUDHOE SAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
JANUARY, 2002
Page 1
Iunplanned Events less than or equal to 1 hour
DATE . .. TIME·· VOLUME· ··DESCRIPTION OF INCIDENT & CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
. ACTION TAKEN TOELfMINA TE CAUSE ......
Not required for unplanned events whic
are less than or equal to 1 hour
I
TOTAL
o
lunPlanned Events greater than 1 hour
DATE TIME· . VOLUME DESCRIPTION OF INCIDENT & CAUSE
1/21/2002 1130-1905 186 See attachments
TOTAL 186
I
ACTION TAKEN TOELfMINATE CAUSE
See attachments
Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
DATE· . TIME VOLUME . DESCRIPTiON OF INCIDENT & CAUSE
1/15/2002 0030-0035 156 See attachments
1/15/2002 0105-0110 35
1/15/2002 0130-0140 141
1/24/2002 0730-0737 141
1/25/2002 0108-0113 141
1/26/2002 1550-1555 45
1/27/2002 1445-1455 420
TOTAL 1,079
Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mct
·DA TE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
See attachments
TOTAL 0
ACTION TAKEN TO ELIMINATE CAUSE .
See attachments
I
I
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour & not
exceeding 5,000 MCF
Planned Events> 1 hour and
exceeding 5,000 MCF
Pilot Purge
Assist
o
186
1,079
o
TOTAL FLARED VOLUME
REPORT NO: 02-0025
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 15 Jan 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Controlled Blowdow 00:30 00:35 o Hrs 5Mins D D ~ 156 MSCF
2. Controlled Blowdow 01:05 01:10 o Hrs 5Mins D D ~ 35 MSCF
3. Controlled Blowdow 01:30 01:40 OHrs 10 Mins D D ~ 141 MSCF
TOTAL VOLUME 332 MSCF
First Determination of Cause:
1. Normal shutdown/blowdown for turbine overhaul TIC 1811 /
2. esd test tic 1811
3. 1802 tic shutdown (ESD test inititated) for control system maintenance
Action Taken to Stop Flaring:
1. None necessary (normal blowdown for unit shutdown)
2.
3.
Monday, January 28, 2002
Page 1 of 1
REPORT NO: 02-0032
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 21 Jan 2002
SYSTEM
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
11 :30 19:05 7 Hrs 35Mins ~ D D 186 MSCF
TOTAL VOLUME 186 MSCF
1. Flare/Relief Valve
First Determination of Cause: )
1. Flaring due to Electrical/lnstrumentation malfunction during start up attempts after maint.on TIC
1802.
Action Taken to Stop Flaring:
1. Instrumentation determined inability to start. Ceased start attempts until maint. repair completed.
Monday, January 28, 2002
Page 1 of 1
REPORT NO: 02-0065
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 24 Jan 2002
TIME OF FLARING Black
SYSIEM______mStarLm~top.--nu[ation---lntermittenL..--Smoke
1. Controlled Blowdow 07:30 07:37 0 Hrs 7 Mins D D
Planned_)lOLUME_
~ 141 MSCF
TOTAL VOLUME
141 MSCF
First Determination of Cause: ./
1. TIC 1806 SID for nozzle maintenance.
Action Taken to Stop Flaring:
1. TIC depressured.
Wednesday, January 30, 2002
Page 1 of 1
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 25 Jan 2002
TIME OF FLARING
Start Stop Duration
1. Controlled Blowdow 01 :08 01: 13 0 Hrs 10 Mins
SYSTEM
First Determination of Cause:
1. Shut down TIC 1802 for maintenance repairs.
Action Taken to Stop Flaring:
1.
Monday, January 28, 2002
Black
Intermittent Smoke
D D
REPORT NO: 02-0048
Planned VOLUME
~ 141 MSCF
TOTAL VOLUME
141 MSCF
J
Page 1 of 1
REPORT NO: 02-0051
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 26 Jan 2002
SYSTEM
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
15:50 15:55 o Hrs 5Mins D D ~ 45 MSCF
TOTAL VOLUME 45 MSCF
1. Controlled Blowdow
First Determination of Cause: ./
1. TIC 1802 was pressure checked after maintenance repairs, shut down to repair valve stem leak.
Depressured to 50 psi.
Action Taken to Stop Flaring:
1. Turbine compressor train depressured for maint. TIC restarted.
Monday, January 28, 2002
Page 1 of 1
REPORT NO: 02-0056
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 27 Jan 2002
TIME OF FLARING
Start Stop Duration
1. Controlled Blowdow 14:45 14:55 0 Hrs 10 Mins
SYSTEM
Black
Intermittent Smoke
D D
Planned VOLUME
~ 420 MSCF
TOTAL VOLUME
420 MSCF
First Determination of Cause: j
1. Turbine Compressor 1876 shut down and depressured to repair low stage compressor seals.
Action Taken to Stop Flaring:
1.
Monday, January 28, 2002
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 02/2002
Disposition Volume MCF*
1. Sold 1,956,392
2. Reinjected 206,424,524
3. Flared or vented less than 1 hour. 1,352
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 29,736
6. Used for lease operations Fuel 5,291,035
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 213,703,039
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 232,155,027
11. Transferred to: CGF 19,899,206
Remarks:
I hereby ce(J, that t~fOregOingo~ true and correct to the best of my knowledge.
Signature: ,n. ..Å '^....a 'I. Title: SUPERVISOR
Form 10-422 (Revised 4/95)
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
Page 1
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
FEBRUARY, 2002
~Unplanned Events less than or equal to 1 hour
·········D.i¥:rEnt/············/:·/;;tt;rlJII~··················;·;;,,~~p:JII~;n/·······DIi!SCI'UP:rIONtOFINCIDEN:rt~C.i¥uSIi!/·... .. ·~~;rl~NnJI~IÇJ;fiI[~~~!JIIIN~I!;·Ç~p:ª~;t.;/
2/1/2002 0525-0531 93 Not required for unplanned events which Not required for unplanned events whi
2/1/2002 1125-1131 93 are less than or equal to 1 hour are less than or equal to 1 hour
2/1/2002 1315-1324 156
2/1/2002 1340-1346 93
2/1/2002 1415-1500 186
2/3/2002 0037-0047 91
2/3/2002 1230-1240 51
2/4/2002 2215-2225 135
2/4/2002 2343-2348 8
TOTAL 906
~Unplanned Events greater than 1 hour
... . DATE ..... · TIME·· ··VOLUMEDESCRIPTIONOFINCIDENT&CAUSE. .... ACTION TAKEN TO ELIMINATE CAUSE
See attachments See attachments
TOTAL 0
~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
;nD.i¥,,J;t;/. ...... ·/.n''lfIIJ;n;;c··· . ···VOLUME; ·DeScfllp:rl~f'.It~F/I~!DEN:r~tcAºSE~CTlPf'.IT~KEf'4T~el.L!fIIlf'.I~''eC~IJ$e
2/1/2002 0400-0403 3 See attachments See attachments
2/3/2002 0030-0035 59
2/3/2002 1200-1210 91
2/3/2002 1430-1440 51
2/3/2002 1755-1805 93
2/4/2002 0530-0535 8
2/13/2002 0045-0050 141
TOTAL 446
Planned Events Exeeedin 1 Hour OR Exeeedin 5000 Met
See attachments
TOTAL
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
o
446
o
TOTAL FLARED VOLUME
31,088
REPORT NO: 02-0077
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 01 Feb 2002
TIME OF FLARING Black
SYSTEM Start Stop DjJ[~ttent Smoke Planned VOLUM.E.-
1. Controlled Blowdow 04:00 04:03 OHrs 3Mins 0 0 ~ 3 MSCF
2. Flare/Relief Valve 05:25 05:31 OHrs 6Mins 0 D 0 93 MSCF
3. Flare/Relief Valve 11:25 11 :31 OHrs 6Mins 0 D 0 93 MSCF
4. Flare/Relief Valve 13:15 13:24 OHrs 9Mins 0 D D 156 MSCF
5. Flare/Relief Valve 13:40 13:46 OHrs 6Mins D 0 0 93 MSCF
6. Controlled Blowdow 14:15 15:00 OHrs 45 Mins ~ D 0 186 MSCF
TOTAL VOLUME 624 MSCF
First Determination of Cause:
1. Venting TIC 1811 in preparation for valve sequence, 50# to 0#.
2. TIC 1811, oil leak on sweet seal oil drain line.
3. ESD'D TIC 1811 for oil leak on sweet seal oil line sight glass.
4. TIC tripped, cause obscure.
5. ESD'D TIC 1811 gas leak in compressor skid area.
6. Pressure/Depressure of compressor for equipment failure investigation.
Action Taken to Stop Flaring:
1. Closed flare valve.
2. Compressor depressured.
3. TIC depressured.
4. TIC depressured.
Tuesday, February 26, 2002
Page 1 of 2
FACILITY: CCP
8. TIC depressured.
9. Investigation complete.
Tuesday, February 26, 2002
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 01 Feb 2002
REPORT NO: 02-0077
Page 2 of 2
REPORT NO: 02-0088
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 03 Feb 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration IntermittenL-Smo.ktL....PJa~'lOLU~
1. Controlled Blowdow 00:30 00:35 OHrs 5Mins D D ~ 59 MSCF
2. Flare/Relief Valve 00:37 00:47 OHrs 10 Mins D D D 91 MSCF
3. Controlled Blowdow 12:00 12:10 OHrs 10 Mins D D ~ 91 MSCF
4. Flare/Relief Valve 12:30 12:40 OHrs 10 Mins D D D 51 MSCF
5. Controlled Blowdow 14:30 14:40 OHrs 10 Mins D D ~ 51 MSCF
6. Controlled Blowdow 17:55 18:05 OHrs 10 Mins D 0 ~ 93 MSCF
TOTAL VOLUME 436 MSCF
First Determination of Cause:
1. TIC 1811 - Depressuring from 2300psi to 500psi. Pressure testing after a major
overhauVcompressor rebuild. Ready to start.
2. TIC 1811 tripped during startup due to starting turbine bog down
3. TIC 1809 SID in preparation of engineering test
4. TIC 1809 tripped due to gear box high axial position.
5. TIC 1809 manually shut down to install test probes
6. TIC 1809 manually shut down to check gearbox pattern
Action Taken to Stop Flaring:
1. Closed vent valves.
2. TIC depressured.
3. TIC depressured.
4. TIC depressured
Tuesday, February 26, 2002
Page 1 of 2
bp
FACILITY: CCP
8. TIC depressured
9. TIC depressured.
Tuesday, February 26, 2002
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 03 Feb 2002
REPORT NO: 02-0088
Page 2 of 2
REPORT NO: 02-0096
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 04 Feb 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME_
1. Controlled Blowdow 05:30 05:35 OHrs 5Mins D D ~ 8 MSCF
2. Flare/Relief Valve 22:15 22:25 OHrs 10 Mins D 0 0 135 MSCF
3. Controlled Blowdow 23:43 23:48 OHrs 5Mins D D D 8 MSCF
TOTAL VOLUME 151 MSCF
First Determination of Cause:
1. TIC 1806 manual stop from valve sequence. Depressures from 100psi to 50psi
2. TIC 1805 tripped due to instrument problem
3. TIC 1805 manually depressured to holding pressure after attempting a restart
Action Taken to Stop Flaring:
1. TIC depressured to holding pressure
2. TIC depressured.
3. TIC depressured to holding pressure
Tuesday, February 26, 2002
Page 1 of 1
REPORT NO: 02-0103
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 13 Feb 2002
SYSTEM
1. Flare/Relief Valve
TIME OF FLARING Black
-5tart Stop Dur.a~--.lntermitten!...-S~anned
00:45 00:50 0 Hrs 5 Mins 0 0 ~
TOTAL VOLUME
First Determination of Cause:
1. Shut-Down TIC 1801 For Maint.
Action Taken to Stop Flaring:
1. System depressured
Tuesday, February 26, 2002
VOLUME
141 MSCF
141 MSCF
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 03/2002
Disposition Volume MCF*
1. Sold 3,244,636
2. Reinjected 226,473,879
3. Flared or vented less than 1 hour. 1,292
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 32,396
6. Used for lease operations Fuel 5,953,682
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 235,705,885
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS 1, FS2, FS3, GC1, GC2, GC3 254,484,207
11. Transferred to: CGF 21,397,925
Remarks:
I hereby ce~ Öt t~e fOregOin.~is true and correct to the best of my knowledge.
Signature: . . A '''.^ 11 Title: SUPERVISOR
Form 1 0-422 (Revised 4/95)
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
Page 1
SP EXPLORATION (ALASKA) INC.
PRUDHOE SAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
MARCH, 2002
tun planned Events less than or equal to 1 hour
DATE TIME VOLUME· DESCRIPTION OF INCIDENT & CAUSE
3/8/2002 0615-0620 135 Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
135
tun planned Events greater than 1 hour
DATE TIME· VOLUME
DESCRIPTION OF INCIDENT & CAUSE
See attachments
o
TOTAL
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events whi
are less than or equal to 1 hour
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
tPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
.. . DATE· .. . .. ..... . TIME . ...... .... VOLUME . DESCRIPTION OF INCIDENT & CAuSE
3/12/2002 1735-1800 650 See attachments
3/28/2002 0800-0805 135
3/30/2002 0520-0525 135
3/30/2002 1305-131 0 135
3/30/2002 1425-1430 51
3/31/2002 1840-1845 51
TOTAL
1,157
tPlanned Events Exceeding 1 Hour OR Exceedin~ 5000 Mct
DATE TIME· VOLUME DESCRIPTION OF INCIDENT & CAUSE .
See attachments
TOTAL 0
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
135
o
1,157
o
TOTAL FLARED VOLUME
33,688
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
bp
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0192
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 12 Mar 2002
TIME OF FLARING
Start Stop Duration
17:35 18:00 0 Hrs 25Mins
Black
Intermittent Smoke
Planned
D D
~
TOTAL VOLUME
First Determination of Cause:
1. Repairing flare lines in flare pit.
Action Taken to Stop Flaring:
1. Recommissioning flare system after flare subsidence, using P37 A V to supply purge gas.
Tuesday,ApnI02,2002
VOLUME
650 MSCF
650 MSCF
Page 1 of 1
bp
REPORT NO: 02-0180
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 28 Mar 2002
TIME OF FLARING
SYSTEM Start Stop Duration
1. Controlled Blowdow 08:00 08:05 0 Hrs 5 Mins
Black
Interm ittent Smoke
Planned
D D
~
VOLUME
135 MSCF
135 MSCF
TOTAL VOLUME
First Determination of Cause:
1. TIC 1805 shut down for spring water wash.
Action Taken to Stop Flaring:
1. Planned operational shut down of TIC 1805 for spring water wash depressured to 50 PSIG case
pressure.
Tuesday, April 02,2002
Page 1 of 1
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0184
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 30 Mar 2002
TIME OF FLARING
Start Stop Duration
05:20 05:25 0 Hrs 5Mins
Black
Intermittent Smoke
D D
TOTAL VOLUME
~
First Determination of Cause:
1 . TIC 1805 leak test.
Action Taken to Stop Flaring:
1. Pressure testing TIC PSV for leaks. Depressured to 50PSIG
Tuesday,ApnI02,2002
Planned
VOLUME
135 MSCF
135 MSCF
Page 1 of 1
bp
REPORT NO: 02-0185
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 30 Mar 2002
SYSTEM
1. Flare/Relief Valve
TIME OF FLARING
Start Stop Duration
13:05 13:10 OHrs 5Mins
Black
Intermittent Smoke
Planned
o D
~
VOLUME
135 MSCF
135 MSCF
TOTAL VOLUME
First Determination of Cause:
1. TIC 1801 shut down for spring water wash.
Action Taken to Stop Flaring:
1. Planned operational shut down of 1801 spring water wash depressured to 50 PSIG case pressure.
Tuesday, April 02, 2002
Page 1 of 1
bp
REPORT NO: 02-0186
BPXA FLARE REPORT
PRUDHOE BAY
FACILlTY:CCP
DATE: 30 Mar 2002
SYSTEM
1. Flare/Relief Valve
TIME OF FLARING
Start Stop Duration
14:25 14:30 0 Hrs 5 Mins
Black
Intermittent Smoke
Planned
o 0
~
VOLUME
51 MSCF
51 MSCF
TOTAL VOLUME
First Determination of Cause:
1. TIC 1801 shut down while spin cooling.
Action Taken to Stop Flaring:
1. Planned operational shut down of TIC 1801 spring water wash depressure to zero ·0· PSIG case
pressure.
Tuesday,ApriI02,2002
Page 1 of 1
bp
REPORT NO: 02-0187
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 31 Mar 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve OHrs OMins 0 D D o MSCF
2. Flare/Relief Valve OHrs Mins 0 0 0 o MSCF
3. Flare/Relief Valve OHrs Mins 0 0 0 o MSCF
4. Flare/Relief Valve 18:40 18:45 OHrs 5Mins D D ~ 51 MSCF
TOTAL VOLUME 51 MSCF
First Determination of Cause:
1.
2. TIC 1801 shut down after water wash
Action Taken to Stop Flaring:
1. .
2. Planned operational flare shut down TIC 1801 for water wash. Depressured to zero ·0" PSIG case
pressure.
Tuesday, April 02. 2002
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 04/2002
Disposition Volume MCF*
1. Sold 2,939,423
2. Reinjected 206,928,335
3. Flared or vented less than 1 hour. 4,354
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 31,812
6. Used for lease operations Fuel 5,596,003
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 215,499,927
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 232,469,777
11. Transferred to: CGF 19,751,333
Remarks:
I hereby cerJ.. () ~h~OregOing is t~e and correct to the best of my knowledge.
Signature: . . Å ~ /\.0"\11 A .A Title: SUPERVISOR
Form 1 0-422 (Revised 4/95)
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 MC 25.235.
Page 1
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
April 2002
'Unplanned Events less than or equal to 1 hour
DATE .. TIME· VOLUME . DESCRIPTION OF INCIDENT & CAUSE
4/8/2002 0130-0140 408 Not required tor unplanned events which
4/8/2002 0200-0205 109 are less than or equal to 1 hour
4/8/2002 0210-0220 408
4/8/2002 0545-0550 8
4/8/2002 2345-2350 135
4/18/2002 0045-0050 408
ACTION TAKEN TO ELIMINATE CAUSE.
Not required tor unplanned events whi'
are less than or equal to 1 hour
TOTAL
1,476
Unplanned Events reater than 1 hour
See attachments
o
See attachments
TOTAL
'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
DATE .......... ·····TIMEV .. ·¥OLUME· ···ºEªjÇflPJ'Iº~ºI7I~ClDE~Tr8<ç~ºªE
4/2/2002 Intermittent 496 See attachments
4/3/2002 Intermittent 721
4/4/2002 Intermittent 704
4/5/2002 Intermittent 96
4/6/2002 Intermittent 560
4/8/2002 0002-0007 109
4/8/2002 0400-0405 141
4/8/2002 0750-0755 51
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
TOTAL
2,878
~Planned Events Exeeedin~ 1 Hour OR Exeeedin~ 5000 Mef
. DATE TIME VOLUME . DESCRIP.TlON OF INCIDENT & CAUSE
See attachments
TOTAL 0
. .. ACTION TAKEN TO ELIMINATE CAUSE ...
See attachments
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
o
2,878
o
TOTAL FLARED VOLUME
36,166
REPORT NO: 02-0196
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 02 Apr 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:01 00:06 OHrs 5 Mins 0 D ~ 135 MSCF
2. Flare/Relief Valve 00:30 00:35 OHrs 5Mins 0 0 ~ 156 MSCF
3. Flare/Relief Valve 04:00 04:05 OHrs 5Mins 0 0 ~ 35 MSCF
4. Flare/Relief Valve 05:53 05:58 OHrs 5Mins 0 0 ~ 14 MSCF
5. Flare/Relief Valve 22:15 22:20 OHrs 5Mins 0 0 ~ 156 MSCF
TOTAL VOLUME 496 MSCF
First Determination of Cause:
1. Shutdown TIC 1808 for PSV's/Maintenance/Water wash
2. Shutdown TIC 1809 for PSV's/Maintenance/Water wash
3. TIC 1809 spincooling stopped.
4. TIC 1808 spincooling stopped.
5. Shutdown TIC 1811 for PSV's/Maintenance/Water wash
Action Taken to Stop Flaring:
1. TIC 1808 Depressured
2. TIC 1809 Depressured
3. TIC 1809 Depressured
4. TIC 1808 Depressured
5. TIC 1811 Depressured
Tuesday, April 30, 2002
Page 1 of 1
bp
REPORT NO: 02-0195
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 03 Apr 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:25 00:30 OHrs 5Mins D D ~ 45 MSCF
2. Flare/Relief Valve 03:15 03:20 OHrs 5Mins D 0 ~ 135 MSCF
3. Flare/Relief Valve 04:30 04:35 OHrs 5Mins D D ~ 35 MSCF
4. Flare/Relief Valve 07:55 08:00 OHrs 5Mins 0 0 ~ 51 MSCF
5. Flare/Relief Valve 08:55 09:00 OHrs 5Mins 0 0 ~ 91 MSCF
6. Flare/Relief Valve 10:50 10:55 OHrs 5Mins 0 0 ~ 32 MSCF
7. Flare/Relief Valve 12:40 12:45 OHrs 5Mins 0 D ~ 156 MSCF
8. Flare/Relief Valve 16:00 16:05 OHrs 5Mins 0 D ~ 35 MSCF
9. Flare/Relief Valve 20:45 20:50 OHrs 5Mins 0 D ~ 141 MSCF
TOTAL VOLUME 721 MSCF
First Determination of Cause:
1. Pressure testing TIC 1808 after PSV PM's.
2. TIC 1802 shutdown for PSV/MaintenancelWater wash
3. TIC 1811 spincooling stopped
4. ESD 1802 from Local Control Room.
5. Shut down 1811 from local control room.
6. Gave 1811 a stop command from local control room.
7. Gave TIC 1810 a stop from the local control room. Spring water wash.
8. ESDed T/C1810 a stop from the local control room. Spring water wash.
9. TIC 1806 SID using F95AV value out of postion trip from local control room. Spring water wash.
Tuesday,Apnl30,2002
Page 1 of 2
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 03 Apr 2002
Action Taken to Stop Flaring:
1. TIC 1808 depressured.
2. TIC 1802 depressured to 50 PSIG.
3. TIC 1811 depressured to 50 PSIG.
4. TIC 1802 depressured to zero PSIG case pressµre.
5. TIC 1811 depressured to 50 PSIG case presssure
6. Stop command given after water wash. Depressured case to 50 PSIG.
7. Depressured compressor case to 50 PSIG.
8. Depressured compressor case to 0 psig.
9. Depressured compressor case to 50 PSIG.
Tuesday,April30,2002
REPORT NO: 02-0195
Page 2 of 2
bp
REPORT NO: 02-0200
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 04 Apr 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 01:25 01:30 OHrs 5Mins D 0 ~ 51 MSCF
2. Flare/Relief Valve 09:45 09:50 OHrs 5Mins D 0 ~ 156 MSCF
3. Flare/Relief ~alve 13:40 13:45 OHrs 5Mins D 0 ~ 35 MSCF
4. Flare/Relief Valve 16:20 16:25 OHrs 5Mins D D ~ 135 MSCF
5. Flare/Relief Valve 16:20 16:25 OHrs 5Mins 0 0 ~ 135 MSCF
6. FlarelRelief Valve 17:30 17:35 OHrs 5Mins 0 0 ~ 141 MSCF
7. Flare/Relief Valve 21:35 21:40 OHrs 5Mins 0 0 ~ 51 MSCF
TOTAL VOLUME 704 MSCF
First Determination of Cause:
1. TIC 1806 ESD after spin cooling for water wash
2. TIC 1812 SID from the local control room. F33AV valve out of position. Spring water wash.
3. TIC 1812 taken of spin cool by local control room ESD button.
4. TIC 1813 SID local control. Valve out of position F95AV. Spring water wash.
5. TIC 1813 sid from local control room. F95AV valve out of position. Spring Water wash.
6. TIC 1813 was pressured up to suction pressure 509 PSlg. ESDed from the CCP main control room.
7. TIC 1813 ESD AFTER SPIN COOLING FOR WATER WASH.
Action Taken to Stop Flaring:
1. Depressured case to zero "0" PSIG.
2. Depressure the comprssor case to 50 PSIG.
Tuesday,Apri/30,2002
Page 1 of 2
bp
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 04 Apr 2002
9. Depressure compressor case to 0 PSIG.
10. Depressured compressor case to 50 PSIG.
11. Depressured the compressor case to 50 PSIG.
12. Depressured compressor case to 0 PSIG.
13. TIC 1813 BLOCKED IN.
Tuesday,ApriI30,2002
REPORT NO: 02-0200
Page 2 of 2
bp
REPORT NO: 02-0204
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 05 Apr 2002
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
11:35 11:40 OHrs 5Mins 0 0 ~ 45 MSCF
12:56 13:01 OHrs 5Mins D 0 ~ 51 MSCF
TOTAL VOLUME 96 MSCF
First Determination of Cause:
1. TIC 1813 SID from local conrol room.
2. TIC 1813 ESD from local control during a starting attempt due to turbine fuel control valve
malfunctioning.
Action Taken to Stop Flaring:
1. Depressured compressor case to 50 PSIG.
2. Depressure compressor case to 0 PSIG.
Tuesday,Apnl30,2002
Page 1 of 1
REPORT NO: 02-0207
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 06 Apr 2002
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
00:40 00:50 OHrs 10 Mins 0 D ~ 408 MSCF
04:00 04:05 OHrs 5Mins 0 D ~ 152 MSCF
TOTAL VOLUME 560 MSCF
First Determination of Cause:
1. TIC 1878 NORMAL STOP FOR WATER WASH & MAINT
2. TIC 1878 ESD'D FROM LCR AFTER SPIN COOLING
Action Taken to Stop Flaring:
1. TIC 1878 VENT VALVES CLOSED
2. TIC 1878 DEPRESSURED
Tuesday,ApriI30,2002
Page 1 of 1
bp
REPORT NO: 02-0212
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 08 Apr 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:02 00:07 OHrs 5Mins 0 0 ~ 109 MSCF
2. Flare/Relief Valve 01:30 01:40 OHrs 10 Mins D 0 D 408 MSCF
3. Flare/Relief Valve 02:00 02:05 OHrs 5Mìns 0 D 0 109 MSCF
4. Flare/Relief Valve 02:10 02:20 OHrs 10 Mins D D D 408 MSCF
5. Flare/Relief Valve 04:00 04:05 OHrs 5Mins D D ~ 141 MSCF
6. Flare/Relief Valve 05:45 05:50 OHrs 5Mins D 0 D 8 MSCF
7. Flare/Relief Valve 07:50 07:55 OHrs 5Mins D 0 ~ 51 MSCF
8. Flare/Relief Valve 23:45 23:50 OHrs 5Mins 0 0 D 135 MSCF
TOTAL VOLUME 1 ,369 MSCF
First Determination of Cause:
1. TIC 1878 NORMAL STOP FOR PLYWOOD REMOVAL AFTER WATER WASH
2. TIC 1876 TRIPPED BECAUSE OF TIC RELIEVING TO TO BAD RELIEF VALVE, CAUSING LO
TEMP ON FLARE HEADER. (TEMP SENSOR FOUND BAD)
3. TIC 1876 TRIPPED ON RESTART DUE TO BAD TEMP SWITCH ON FLARE HEADER
4. TIC 1878 NORMAL STOP TO REPAIR BAD RELIEF VALVE
5. TIC 1813 TRIPPED BY CLOSING OUTLET VALVE FOR WATER WASH
6. TIC 1803 TRIPPED WHILE CRANKING FOR SPIN COOLING?
7. TIC 1803 coming off spin cooling. ESDed from local control room.
8. TIC 1803 TRIPPED, HYDRAULIC PROBLEMS
Action Taken to Stop Flaring:
1. VENT VALVES CLOSED
Tuesday,April30,2002
Page 1 of 2
bp
FACILITY: CCP
11. VENT VALVES CLOSED
12. VENT VALVES CLOSED
13. VENT VALVES CLOSED
14. VENT VALVES CLOSED
15. VENT VALVES CLOSED
16. Depressured to 0 psi.
17. VENT VALVES CLOSED
Tuesday, April 30. 2002
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 08 Apr 2002
REPORT NO: 02-0212
Page 2 of 2
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) MonthlYear of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU OS/2002
Disposition Volume MCF*
1. Sold 2,127,814
2. Reinjected 207,778,716
3. Flared or vented less than 1 hour. 290
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 33,302
6. Used for lease operations Fuel 5,361,879
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 215,302,001
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 232,569,334
11. Transferred to: CGF 21,275,362
Remarks:
I hereby ce71that th~ and correct to the best of my knowledge.
Signature: .0. Title: SUPERVISOR
Form 10-422 (Revised 4/95)
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
May 2002
Page 1
~Unplanned Events less than or equal to 1 hour
DATE TIME VOLUME DE.SCRIPTIONOF]NCIDENT&CAUSE
5/7/2002 0300-0305 14 Not required for unplanned events which
5/7/2002 1217-1227 135 are less than or equal to 1 hour
5/12/2002 1600-1605 141
ACTION TAKEN TO ELIMIN,ÄTfE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
290
~Unplanned Events greater than 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
See attachments
o
. ACTION TAKEN TO ELIMINATE CAUSE .. .
See attachments
TOTAL
'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE.
See attachments
ACTION TAKEN TO EUMINATE CAUSE· .
See attachments
TOTAL
o
~Planned Events Exceeding 1 Hour OR Exceeding 5000 Met
.DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
See attachments
TOTAL 0
.ACTION TAKEN TO EUMINATECAUSE
See attachments
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
o
o
o
TOTAL FLARED VOLUME
33,592
6/6/2002
12:57 PM
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) MonthlYear of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 06/2002
Disposition Volume MCF*
1. Sold 2,116,109
2. Reinjected 195,055,253
3. Flared or vented less than 1 hour. 0
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 32,245
6. Used for lease operations Fuel 5,193,657
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 202,397,264
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 216,683,972
11. Transferred to: CGF 18,296,760
Remarks:
I hereby ceë) that t~ fOregOin~ds true and correct to the best of my knowledge.
Signature: Q. 1 · J'\ - JA Title: SUPERVISOR
Form 10-422 (Revised 4/95)
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
June 2002
Page 1
Iunplanned Events less than or equal to 1 hour
. DATE TIME .. . VOLUME. .. DESCRIPTION OF INCIDENT& CAUSE·
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
o
~Unplanned Events greater than 1 hour
... DATE . TIME . VOLUME
DESCRIPTION OF INCIDENT & CAUSE
See attachments
o
TOTAL
'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
. DATE. . TIME . VOLUME . DESCRIPTION OFINCIDENT & CAUSE
See attachments
. .. ACTION TAKEN TOELIMINATS CAuse ... .
Not required for unplanned events which
are less than or equal to 1 hour
AcnONTAKENTO ELIMINATE CAUSE..·
See attachments
TOTAL
o
~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mct
. ·.DATE TIME . VOLUME DESCRIPTION. OF INCIDENT & CAUSE
See attachments
TOTAL 0
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
o
o
o
o
TOTAL FLARED VOLUME
32,245
. ACTION TAKEN TO ELIMINATE CAUSE. .
See attachments
ACTION TAKEN TO .ELlMINATE CAUSE·
See attachments
7/9/2002
11:06AM
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 07/2002
Disposition Volume MCF*
1. Sold 2,803,382
2. Reinjected 176,046,562
3. Flared or vented less than 1 hour. 1,297
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 28,954
6. Used for lease operations Fuel 5,124,167
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 184,004,362
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 194,733,868
11. Transferred to: CGF 13,781,681
Remarks;
I hereby ce12êr tr:::.egOing ~e and correct to the best of my knowledge.
Signature: ~. J ^ -^ A Title: SUPERVISOR
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
Form 10-422 (Revised 4/95)
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
July 2002
Page 1
Unplanned Events less than or equal to 1 hour
7/23/2002
7/24/2002
7/25/2002
7/26/2002
7/26/2002
7/26/2002
7/27/2002
7/27/2002
7/28/2002
7/29/2002
7/30/2002
7/30/2002
7/30/2002
1027-1033
2220-2225
2030-2035
0810-0820
1115-1120
2325-2330
0015-0020
0220-0225
2045-2055
1300-1305
1010-1015
1520-1525
1620-1625
135 Not required for unplanned events which
135 are less than or equal to 1 hour
135
156
35
135
8
8
156
14
8
8
8
TOTAL
941
~Unplanned Events greater than 1 hour
....... >DA,.TE· ....... .. . .··.iIME ....... ··.V9I..UME ... .DE$ºR\~TIONOFINº'DJ;Ni.t..CA,U$IL·
See attachments
TOTAL 0
Not required for unplanned events which
are less than or equal to 1 hour
I
· . ..... . .... A,CTIQNTA{E:NT,qEtlMIHA113ºAQ$J;¡~è· ... ... .
See attachments
Planned Events Less Than or Equal 1 Hour AND Not Exeeedin 5000 Met
7/16/2002
7/16/2002
7/23/2002
7/31/2002
0003-0013
0300-0305
2230-2235
0800-0805
TOTAL
135 See attachments
14
51
156
356
See attachments
Planned Events Exeeedin 1 Hour OR Exeeedin 5000 Met
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
See attachments
o
TOTAL
o
356
o
TOTAL FLARED VOLUME
30,251
See attachments
8/8/2002
2:15 PM
bp
REPORT NO: 02-0452
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 16 Jut 2002
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
00:03 00:13 OHrs 10 Mins D D ~ 135 MSCF
03:00 03:05 OHrs 5Mins D D ~ 14 MSCF
TOTAL VOLUME 149 MSCF
First Determination of Cause:
1. TURBINE SHUTDOWN FOR PLANNED MAINTENANCE.
2. TURBINE SHUTDOWN FROM SPINCOOL FOR PLANNED MAINTENANCE.
Action Taken to Stop Flaring:
1.
2.
Thursday, August 01, 2002
Page 1 of 1
REPORT NO: 02-0462
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 23 Jul2002
TIME OF FLARING
SYSTEM Start Stop Duration
1. Controlled Blowdow 10:27 10:33 0 Hrs 6 Mins
2. Controlled Blowdow 22:30 22:35 0 Hrs 5Mins
Black
Intermittent Smoke Planned VOLUME
0 D 0 135 MSCF
0 D ~ 51 MSCF
TOTAL VOLUME 186 MSCF
First Determination of Cause:
1. TIC 1813 tripped due to bog-down caused by dirty oil filters affecting fuel valve.
2. TIC 1813 depressured after spin cooling.
Action Taken to Stop Flaring:
1. TIC depessured.
2. TIC depessured.
Thursday, August 01, 2002
Page 1 of 1
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0505
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 31 Jul 2002
TIME OF FLARING
Start Stop Duration
08:00 08:05 0 Hrs 5 Mins
First Determination of Cause:
1. work on f-57av
Action Taken to Stop Flaring:
1. tic done flaring
Thursday, August 01, 2002
Black
Intermittent Smoke
o 0
Planned
TOTAL VOLUME
~
VOLUME
156 MSCF
156 MSCF
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s)
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU
ear of Disposition
08/2002
Disposition Volume MCF*
1. Sold 2,574,121
2. Reinjected 190,219,593
3. Flared or vented less than 1 hour. 1,125
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 28,954
6. Used for lease operations Fuel 5,381,090
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 198,204,883
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 211,447,507
11. Transferred to: CGF 16,635,853
Remarks:
I hereby cet:!. to t~egOing t true and correct to the best of my knowledge.
Signature: ..A ~ . A .h Title: SUPERVISOR
Form 10-422 Revised 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 MC 25.235.
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
August 2002
lunplanned Events less than or equal to 1 hour .1
...........~~¡t¡I:;...................... ······!JiII1ðI:;J····· ·····················¥~fE!!Il1ðJ;y;;jªJ;~~f.t.!¡!¡t¡IØf1l¡~;II'1i!I~~;¡~;~!!I~;Y···F.Y·Jt~~~Øf1lj¡t¡~~'ª'I1!¡~!·§!.f,!I1ðIM1'Ë!~~f«~Jª;;j!t!Jit··
8/1/2002 1445-1450 135 Not required for unplanned events which Not required for unplanned events which
8/2/2002 1320-1325 135 are less than or equal to 1 hour are less than or equal to 1 hour
8/6/2002 2124-2129 135
8/7/2002 1205-1210 135
8/7/2002 1230-1235 135
8/9/2002 0520-0525 135
8/14/2002 1925-1930 135
Page 1
TOTAL
945
~Unplanned Events greater than 1 hour
.··.·DATETIME. ·YOLUMEÐESCRP.TION~FINClÅ“Nr;&CA!!ISE..· ·AC:TløNrAKENTOELlMINA1Ǻ~I,J$E:.· ...
See attachments See attachments
TOTAL 0
~..~.~~..~.~.~.~....~.~.~.~~.~....~.e~~...~~~.~~~...E.~~.~I..1~.~.~.r.~~.[:).~~t.:~~.~~~i~.~.5~~~ ...~~t..................
i~ATE..TIIIIIE·¥::;)"'ºME·i.y·DESCR¡!T!~N;~Jfi!NC!DgNT;~¡'CA!;Jset···;;;A~ØN;¡t¡A~E.l1!n¡t¡Ø;E.!¥IMIM~ºAI~;·¡·:;;;
8/1/2002 1603-1608 45 See attachments See attachments
8/1/2002 2105-2110 45
8/2/2002 1135-1140 45
8/2/2002 1553-1558 45
TOTAL
180
~Planned Events Exeeedin\l 1 Hour OR Exeeedin~ 5000 Met. . .. ..
. DATE ... .. ... . TIME . . ... . . ... VOLUME.DESCRI¡!TlONOFIN.CIDENH<CAUSE
See attachments
TOTAL 0
I
.. ... ACTI::;)NTAKEN TO EUI1ðINATE'CAUSE ........
See attachments
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour 0
Planned Events < 1 hour and not 180
exceeding 5,000 MCF
Planned Events> 1 hour or 0
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME 30,079
9/11/2002
3:20 PM
REPORT NO: 02-0507
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 01 Aug 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 14:45 14:50 OHrs 5Mins D D D 135 MSCF
2. Flare/Relief Valve 16:03 16:08 OHrs 5Mins D 0 ~ 45 MSCF
3. Flare/Relief Valve 21:05 21:10 OHrs 5Mins D D ~ 45 MSCF
TOTAL VOLUME 225 MSCF
First Determination of Cause:
1. TIC 1813 tripped due to vibration(?)
2. Attempted to start TIC 1813
3. Attempted to start TIC 1813.
Action Taken to Stop Flaring:
1. Depressured to holding pressure of 50 psi
2. Depressured to holding pressure of 50 psi
3. Depressured to holding pressure of 50 psi
VVednesday, August 21, 2002
Page 1 of 1
REPORT NO: 02-0510
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 02 Aug 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 11:35 11:40 OHrs 5Mins 0 D ~ 45 MSCF
2. F/are/Relief Valve 13:20 13:25 OHrs 5Mins D 0 0 135 MSCF
3. Flare/Relief Valve 15:53 15:58 OHrs 5Mins D 0 ~ 45 MSCF
TOTAL VOLUME 225 MSCF
First Determination of Cause:
1. Gave TIC 1813 a STOP command after a valve sequence during troubleshooting session.
2. TIC 1813 tripped - reason not determined
3. TIC 1813 given a STOP command. Ratchet pump wouldn't run. Had to put it on crank to prevent
shaft from bowing.
Action Taken to Stop Flaring:
1. Depressured compressor
2. Depressured compressor
3. Depressured compressor
VVednesday, August 21, 2002
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 09/2002
Disposition Volume MCF* *Indicate contribution of each pool to total.
1. Sold 2,346,600 Pool Name Code Percent
2. Reinjected 177,494,409 PRUDHOE 640150 99.75%
3. Flared or vented less than 1 hour. 4,299 PBU Midnight Sun Undefined 640158 0.25%
4. Flared or vented greater than 1 hour 827 /
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 32,724
6. Used for lease operations Fuel 5,187,600
Assist 0
7. Other Lift Gas, Off Field 0 . - >
.........>.....
TOTAL items 1 - 7 185,066,459 1. Safety <32- 7 MCF
8. NGL gas equivalent produced 0 2. Lease Use MCF
9. Purchased gas 0 3. Conserv. Purposes MCF
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 198,163,929 b~'~ /1 .
;y-{ ð~
Date
11. Transferred to: CGF 15,944,874
Remarks: N~te: All volumes must be correllnl U:l'!' IT
pSla and to a temperature of 60 ... p~ fìl4JM>Y
the 20th of the month following the month of disposition.
I hereby ce(j'.that th~fOregOingpS true and correct to the best of my knowledge. Authority 20 AAC 25.235. OCT 1 5 2002
Signature: .Ct ( .Å A JI.IIA 1J.. Title: SUPERVISOR
..-
0ßt3-
Form 10-422 (Revised 4/95)
AncDoraaø
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
September 2002
Page 1
,unplanned Events less than or e9ual to 1 hour
DÄTS ... . .. . tIMS· ... VOL.UME PEScãIÞtIPNPIPINcIPSNt8.CÄUSS
9/6/2002 1745-1750 141 Not required for unplanned events which
9/6/2002 1845-1850 8 are less than or equal to 1 hour
9/6/2002 2120-2125 45
9/7/2002 0015-0025 135
9/7/2002 0330-0335 14
9/7/2002 0445-0455 135
9/7/2002 0845-0850 8
9/7/2002 1150-1155 8
9/7/2002 1405-1415 135
9/7/2002 1630-1635 8
9/8/2002 0010-0020 135
9/8/2002 0325-0330 14
9/8/2002 1405-1410 8
9/8/2002 2330-2335 8
~Õ2 0045=6T10 30~
9/10/2002 0030-0035 51
9/10/2002 1700-1705 135
9/11/2002 0045-0050 91
9/11/2002 0120-0125 91
9/11/2002 0430-0435 135
9/11/2002 1710-1715 14
9/11/2002 2330-2335 91
9/20/2002 0100-0110 159
9/20/2002 1830-1835 32
9/20/2002 2100-2105 32
9/20/2002 2150-2155 32
9/23/2002 1700-1710 135
9/24/2002 0405-0415 156
9/24/2002 0645-0655 32
9/24/2002 0830-0840 32
9/27/2002 1530-1538 135
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
2,185
~unplanned Events ~reater than 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE
9/9/2002 0030-0945 159 Intermittent - See attachments
9/24/2002 0900-1120 455 Intermittent
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
TOTAL
614
10/15/2002
1:41 PM
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
September 2002
~Planned Events Less Than or Equal 1 Hour AND Not Exeeedin~ 5000 Met
.DATe TIMe VOLI.J.Me DEsCRIPTIONOFINcIDeNT&:cAI.J.SE
9/6/2002 0006-0011 135 See attachments
9/6/2002 0006-0011 156
9/6/2002 0330-0335 14
9/6/2002 0400-0405 35
9/9/2002 1705-1710 156
9/9/2002 2025-2030 35
9/9/2002 2100-2105 141
9/11/2002 0755-0800 14
9/11/2002 1212-1217 156
9/11/2002 1440-1445 135
9/11/2002 1630-1635 32
9/11/2002 1820-1825 14
9/12/2002 2320-2325 8
9/13/2002 0030-0035 8
9/13/2002 0430-0435 8
9/13/2002 0850-0858 408
9/13/2002 1215-1220 109
9/15/2002 2315-2320 14
9/15/2002 0510-0515 109
9/15/2002 0840-0845 109
9/15/2002 1011-1016 109
9/16/2002 0010-0015 45
9/16/2002 1215-1220 8
9/28/2002 0605-0610 156
TOTAL 2,114
Page 2
ACTION TAKEN TO EUMINATE CAUSE
See attachments
~Planned Events Exeeedin~ 1 Hour OR Exeeedin~ 5000 Met
DATE TIME VOLUME DESCRIPTION OF INCIDENT" CAUSE
9/9/2002 1130-1545 149 See attachments
9/9/2002 1200-1430 64
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
TOTAL
213
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
614
2,114
213
TOTAL FLARED VOLUME
37,850
10/15/2002
1:41 PM
REPORT NO: 02-0625
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 06 Sep 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:06 00:11 OHrs 5Mins D D ~ 135 MSCF
2. Flare/Relief Valve 00:06 00:11 OHrs 5Mins D D ~ 156 MSCF
3. Flare/Relief Valve 03:30 03:35 OHrs 5Mins D D ~ 14 MSCF
4. Flare/Relief Valve 04:00 04:05 OHrs 5Mins D 0 ~ 35 MSCF
5. FlarelRelief Valve 17:45 17:50 OHrs 5Mins D D D 141 MSCF
6. Flare/Relief Valve 18:45 18:50 OHrs 5Mins D D D 8 MSCF
7. Flare/Relief Valve 21:20 21:25 OHrs 5Mins D D D 45 MSCF
TOTAL VOLUME 534 MSCF
First Determination of Cause:
1. tc 1803 shutdown for fall waterwash
2. tc 1812 shutdown for fall waterwash.
3. esd tc 1803 after spin cooling
4. esd tc 1812 after spin cooling
5. esd tc 1813 insturmentation problem
6. tc 1813 insturmentation problem
7. tc 1813 instrmentation problem found while unit was pressureing up
Action Taken to Stop Flaring:
1. depressured tc
2. depressured tc
Wednesday, September 25,2002
Page 1 of 2
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 06 Sep 2002
'3 .A: depressured tc
<j J« depressured tc
.ç ,}t. depressered unit,repaired t-9 controller
b ~. deperessered unit, repaired problem
7 ~. depressured unit, repaired problem
Wednesday, September 25,2002
REPORT NO: 02-0625
Page 2 of 2
bp
REPORT NO: 02-0635
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 09 Sep 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:30 09:45 9Hrs 15 Mins ~ 0 0 159 MSCF
2. Flare/Relief Valve 00:45 01:10 OHrs 25 Mins ~ 0 0 30 MSCF
3. Flare/Relief Valve 11:30 15:45 4Hrs 15 Mins ~ 0 ~ 149 MSCF
4. Flare/Relief Valve 12:00 14:30 2Hrs 30 Mins ~ 0 ~ 64 MSCF
5. Flare/Relief Valve 17:05 17:10 OHrs 5Mins D D ~ 156 MSCF
6. Flare/Relief Valve 20:25 20:30 OHrs 5Mins D 0 ~ 35 MSCF
7. Flare/Relief Valve 21:00 21:05 OHrs 5Mins D 0 ~ 141 MSCF
TOTAL VOLUME 734 MSCF
First Determination of Cause:
1. intermittent flaring due to instrumentation problems tic 1801
2. intermittent flaring due to instrumentation problem tic 1807
3. intermittent flaring for water wash tic 1804
4. intermittent flaring for water wash tic 1812
5. shutdown tic 1809 for water wash
6. esd tic 1809 for water wash
7. esd tic 1808 for spin cool
Action Taken to Stop Flaring:
1. corrected problem
2. corrected problem
Thursday, October 03, 2002
Page 1 of 2
FACILITY: CCP
S -< depressured unit
~ ~depressured unit
S jJ-; depressured unit
~ jp( depressured unit
7 ..rs: depressured unit
Thursday, October 03, 2002
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 09 Sep 2002
REPORT NO: 02-0635
Page 2 of 2
REPORT NO: 02-0640
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 11 Sap 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:45 00:50 OHrs 5Mins 0 D 0 91 MSCF
2. Flare/Relief Valve 01:20 01:25 OHrs 5Mins 0 0 0 91 MSCF
3. Flare/Relief Valve 04:30 04:35 OHrs 5Mins 0 0 0 135 MSCF
4. Flare/Relief Valve 07:55 08:00 OHrs 5Mins 0 0 ~ 14 MSCF
5. Flare/Relief Valve 12:12 12:17 OHrs 5Mins 0 D ~ 156 MSCF
6. Flare/Relief Valve 14:40 14:45 OHrs 5Mins 0 0 ~ 135 MSCF
7. Flare/Relief Valve 16:30 16:35 OHrs 5Mins 0 0 ~ 32 MSCF
8. Flare/Relief Valve 17:10 17:15 OHrs 5Mins 0 D D 14 MSCF
9. Flare/Relief Valve 18:20 18:25 OHrs 5Mins 0 0 ~ 14 MSCF
10. Flare/Relief Valve 23:30 23:35 OHrs 5Mins 0 0 D 91 MSCF
TOTAL VOLUME 773 MSCF
First Determination of Cause:
1. TC 1809 tripped
IGV relay card malfunction
2. TC 1809 tripped
No speed indication in MCR
3. TC 1802 shut down for water wash
4. tic 1802 esd for water wash
5. shut down tic 1810 for water wash
6. tic 1813 shut down for water wash
7. tic 1810 off of spin cool
8. tic 1813 tripped off spin cool
Thursday, October 03, 2002
Page 1 of 2
bp
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 11 Sep 2002
4 .~tlc 1813 shut down after spin cool
1'f TC 1810 tripped
I () Instrumentation problem?
Action Taken to Stop Flaring:
1. Depressured unit
2. Depressured unit
3. Depressured unit
4. depressured unit
5. depressured unit
6. depressured unit
7. depressured unit
8. depressured unit
9. depressured unit
10. Depressured unit
Thursday, October 03, 2002
REPORT NO: 02-0640
Page 2 of 2
bp
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0644
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 12 Sap 2002
TIME OF FLARING
Start Stop Duration
23:20 23:2Jf.. 0 Hrs 5 Mins
5'
First Determination of Cause:
1. TIC 1802 valve sequence prior to start up.
Action Taken to Stop Flaring:
1. Depressured and started TIC
Wednesday, September 25,2002
Black
Intermittent Smoke
D 0
Planned
TOTAL VOLUME
Iill
VOLUME
8 MSCF
8 MSCF
Page 1 of 1
bp
REPORT NO: 02-0646
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 13 Sep 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 00:30 00:35 OHrs 5Mins 0 0 ~ 8 MSCF
2. Flare/Relief Valve 04:30 04:35 OHrs 5Mins 0 0 ~ 8 MSCF
3. Flare/Relief Valve 08:50 08:58 OHrs 8Mins 0 D ~ 408 MSCF
4. Flare/Relief Valve 12:15 12:20 OHrs 5Mins D D ~ 109 MSCF
TOTAL VOLUME 533 MSCF
First Determination of Cause:
1. tic 1802 gave tic a stop. Mark 6 w. w. system did not work.
2. tic 1802 gave tic a stop. Finished water washing.
3. tic 1876 gave tic a stop for sched. Maint.
4. tic 1876 gave tic a stop. After spin cooling.
Action Taken to Stop Flaring:
1. depressured compo To 50#.
2. depressured compo To 50#
3. depressured compo To 175#
4. depressured compo
Wednesday, September 25,2002
Page 1 of 1
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0653
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 15 Sep 2002
TIME OF FLARING
Start Stop Duration
23:15 23:20 OHrs 5Mins
First Determination of Cause:
1. tic 1876 valve seq. for leak test
Action Taken to Stop Flaring:
1. stopped valve seq. Tic 1876
Wednesday, September 25,2002
Black
Intermittent Smoke
D 0
Planned
TOTAL VOLUME
~
VOLUME
14 MSCF
14 MSCF
Page 1 of 1
bp
REPORT NO: 02-0649
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 15 Sep 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 05:10 05:15 OHrs 5Mins 0 0 ~ 109 MSCF
2. Flare/Relief Valve 08:40 08:45 OHrs 5Mins 0 0 ~ 109 MSCF
3. Flare/Relief Valve 10:11 10:16 OHrs 5Mins 0 D ~ 109 MSCF
TOTAL VOLUME 327 MSCF
First Determination of Cause:
1. tic 1876 pressure test compo After psv p.m.s
2. tic 1876 water washed turbine
3. tic 1876 gave tic a stop. Finished water wash.
Action Taken to Stop Flaring:
1. depressured tic 1876 to 175#
2. tic 1876 depressured compo To 175#
3. depressured compo To 175#
Wednesday. September 25,2002
Page 1 of 1
bp
REPORT NO: 02-0654
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 16 Sep 2002
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
00:10 00:15 OHrs 5Mins D D ~ 45 MSCF
12:15 12:20 OHrs 5Mins D D ~ 8 MSCF
TOTAL VOLUME 53 MSCF
First Determination of Cause:
1. tic 1813 valve seq.
2. TIC 1813 shut down after water wash.
Action Taken to Stop Flaring:
1. completed valve seq. Tic 1813. Depressured to 50#.
2. Depressured unit.
Wednesday, September 25,2002
Page 1 of 1
bp
REPORT NO: 02-0667
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 24 Sep 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 04:05 04:15 OHrs 10 Mins 0 0 D 156 MSCF
2. Flare/Relief Valve 06:45 06:55 OHrs 10 Mins 0 D 0 32 MSCF
3. Flare/Relief Valve 08:30 08:40 OHrs 10 Mins 0 D 0 32 MSCF
4. Flare/Relief Valve 09:00 11:20 2Hrs 20 Mins ~ D D 455 MSCF
TOTAL VOLUME 675 MSCF
First Determination of Cause:
1. TIC 1811 normal stop for Turbine oil leak repair
2. TC 1811 shut down from spin cool to repair oil leak.
3. TC 1811 tripped on turbine vibration.
4. TC 1811 tripped on low seal oil DP 5 times. Each trip flared 91 mscf for a total of 455mscf. Each trip
flared for 10 minutes.
Action Taken to Stop Flaring:
1. unit depressured to 50 psig
2. Depressured to 50 psìg
3. Depressured to 50 psìg
4. Depressured to 50 psig on each trip.
Wednesday, September 25, 2002
Page 1 of 1
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0680
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 28 Sep 2002
TIME OF FLARING
Start Stop Duration
06:05 06: 10 0 Hrs 5 Mins
First Determination of Cause:
1. Tic 1811 was stutdown for maintence.
Action Taken to Stop Flaring:
1.
Tuesday,October01,2002
Black
Intermittent Smoke
o D
Planned
TOTAL VOLUME
~
VOLUME
156 MSCF
156 MSCF
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 10/2002
Disposition Volume MCF*
1. Sold 2,403,752
2. Reinjected 210,210,275
3. Flared or vented less than 1 hour. 557
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 33,254
6. Used for lease operations Fuel 6,110,927
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 218,758,765
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 233,915,144
11. Transferred to: CGF 18,353,985
Remarks:
I hereby ce~ that t~ foregoinvis true and correct to the best of my knowledge.
Signature: . Q. J.. lA Title: SUPERVISOR
Form 10-422 (Revised 4/95)
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
SP EXPLORATION (ALASKA) INC.
PRUDHOE SAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
October 2002
Page 1
IUnplanned Events less than or equal to 1 hour
DATE· TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
10/6/2002 . 1315-1325 408 Not required for unplanned events which
are less than or equal to 1 hour
ACTION.TAKEN.TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
408
~Unplanned Events ~reater than 1 hour
DATE TIME· VOLUME.
DESCRIPTION OF INCIDENT & CAUSE
See attachments
ACTION. TAKEN TO EUMINATE CAUSE.
See attachments
TOTAL
o
~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
DATE TIME·. VOLUME· . DESCRÞTIONOFINCIDENT&CAUSE
10/29/2002 0125-0130 135 See attachments
10/29/2002 0350-0355 14
. ACTION TAKEN TO ELIMINATE CAUSE .
See attachments
TOTAL
149
~Planned Events Exceedin~ 1 Hour OR Exceedin!ilSOOO Met
. DATE TIME· VOLUME· DESCRIPTION OF INCIDENT & CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
TOTAL
o
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
408
o
149
o
TOTAL FLARED VOLUME
33,811
11/7/2002
3:15PM
REPORT NO: 02-0746
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 29 Oct 2002
SYSTEM
1. FJare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
01:25 01:30 OHrs 5Mins 0 D ~ 135 MSCF
03:50 03:55 OHrs 5Mins D 0 ~ 14 MSCF
TOTAL VOLUME 149 MSCF
First Determination of Cause:
1. tic 1805 shut down for sched. Maint. Tic major overhaul and mark 6.
2. tic 1805 esd machine after spin cool.
Action Taken to Stop Flaring:
1. depressured tic 1805
2. depressured tic 1805
Thursday, October 31,2002
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 11/2002
Disposition Volume MCF*
1. Sold 2,255,110
2. Reinjected 190,562,421
3. Flared or vented less than 1 hour. 1,513
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 32,217
6. Used for lease operations Fuel 6,160,364
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 199,011,625
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 214,391,068
11. Transferred to: CGF 17,829,514
Remarks:
I hereby cefj, Õ.t~ fOregOin~~S true and correct to the best of my knowledge.
Signature: , . ..A -f/,.- h Title: SUPERVISOR
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
Form 10-422 (Revised 4/95)
BP EXPLORATION (ALASKA) INC.
PRUDHOE BAY UNIT· CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
November 2002
Page 1
lunp'anned Events less than or equal to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
11/30/2002 1745-1750 135 Not required for unplanned events which
11/30/2002 1805-1810 45 are less than or equal to 1 hour
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
180
Junp'anned Events ~reater than 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
TOTAL
o
~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met
DATE TIME VOLUME DE$CRIPTlONiOFINCIPENT&CAU$E
11/3/2002 1630-1635 135 See attachments
11/3/2002 1930-1935 14
11/3/2002 2230-2235 159
11/4/2002 1735-1740 135
11/5/2002 0130-0135 135
11/5/2002 0950-0955 159
11/14/2002 1915-1920 135
11/15/2002 1815-1820 135
11/24/2002 1810-1818 135
11/24/2002 2100-2105 14
11/25/2002 0840-0845 14
11/25/2002 0930-0935 14
11/28/2002 1 020-1 025 135
11/28/2002 1305-1310 14
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
TOTAL
1,333
IPlanned Events Exceeding 1 Hour OR ExceedinS! 5000 Met
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
TOTAL 0
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour 0
Planned Events < 1 hour and not 1,333
exceeding 5,000 MCF
Planned Events> 1 hour or 0
exceeding 5,000 MCF
Pilot Purge
Assist
TOTAL FLARED VOLUME 33,730
12/9/2002
11:10AM
REPORT NO: 02-0764
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 03 Nav 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve 16:30 16:35 OHrs 5Mins D 0 ~ 135 MSCF
2. Flare/Relief Valve 19:30 19:35 OHrs 5Mins 0 0 ~ 14 MSCF
3. Flare/Relief Valve 22:30 22:35 OHrs 5Mins D 0 ~ 159 MSCF
TOTAL VOLUME 308 MSCF
First Determination of Cause:
1. shut down tic 1803 for maintainance work
2. esd tic 1803 for maintainance work
3. esd tic 1810 for maintainance work
Action Taken to Stop Flaring:
1. depressured unit
2. depressured unit
3. depressured unit
Tuesday,November26,2002
Page 1 of 1
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0768
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 04 Nav 2002
TIME OF FLARING
Start Stop Duration
17:35 17:40 0 Hrs 5 Mins
First Determination of Cause:
1. shutdown tic 1807 for maintainance work
Action Taken to Stop Flaring:
1. depressured unit
Tuesday, November 26, 2002
Black
Intermittent Smoke
D D
Planned
TOTAL VOLUME
~
VOLUME
135 MSCF
135 MSCF
Page 1 of 1
REPORT NO: 02-0770
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 05 Nav 2002
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
01:30 01:35 OHrs 5Mins D 0 ~ 135 MSCF
09:50 09:55 OHrs 5Mins D 0 ~ 159 MSCF
TOTAL VOLUME 294 MSCF
First Determination of Cause:
1. tic 1806 shut down for maintainance
2. esd tic 1811 not needed
Action Taken to Stop Flaring:
1. depressured unit
2. depressured unit
Tuesday, December 03, 2002
Page 1 of 1
bp
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0803
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 14 Nov 2002
TIME OF FLARING
Start Stop Duration
19:15 19:20 0 Hrs 5Mins
First Determination of Cause:
1. Shut Down TIC 1805 for Maint.
Action Taken to Stop Flaring:
1. Depressured Gas Train
Tuesday,November26,2002
Slack
Intermittent Smoke
D 0
Planned
TOTAL VOLUME
~
VOLUME
135 MSCF
135 MSCF
Page 1 of 1
FACILITY: CCP
SYSTEM
1. Flare/Relief Valve
REPORT NO: 02-0807
BPXA FLARE REPORT
PRUDHOE BAY
DATE: 15 Nov 2002
TIME OF FLARING
Start Stop Duration
18:15 18:20 OHrs 5Mins
First Determination of Cause:
1. TIC 1805 shut down for maint.
Action Taken to Stop Flaring:
1. Depressured Gas Train
Tuesday,November26,2002
Black
Intermittent Smoke
o D
Planned
TOTAL VOLUME
~
VOLUME
135 MSCF
135 MSCF
Page 1 of 1
bp
REPORT NO: 02-0828
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 24 Nov 2002
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
18:10 18:18 OHrs 8Mins 0 0 ~ 135 MSCF
21:00 21:05 OHrs 5Mins 0 0 ~ 14 MSCF
TOTAL VOLUME 149 MSCF
First Determination of Cause:
1. Oil leak at back end of turbine. Shutdown to repair leak.
2. Put TIC 1805 on spin cool so maint. Could safely work on bulls ass oil leak
Action Taken to Stop Flaring:
1. Depressured TIC 1805
2. stopped cranking machine after exhaust temp was safe for maint. Work
Tuesday, November 26, 2002
Page 1 of 1
REPORT NO: 02-0832
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP DATE: 25 Nav 2002
TIME OF FLARING Black
SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME
1. Flare/Relief Valve OHrs OMins 0 0 D o MSCF
2. Flare/Relief Valve 08:40 08:45 OHrs 5Mins D 0 ~ 14 MSCF
3. Flare/Relief Valve 09:30 09:35 OHrs 5Mins 0 0 ~ 14 MSCF
TOTAL VOLUME 28 MSCF
First Determination of Cause:
1. SID TIC 1805 due to unusual noise in exhaust plenum
2. Depressured TIC 1805 after spin cooling
Action Taken to Stop Flaring:
1. Depressured unit
2. Depressured unit
Tuesday,November26,2002
Page 1 of 1
REPORT NO: 02-0836
BPXA FLARE REPORT
PRUDHOE BAY
FACILITY: CCP
DATE: 28 Nov 2002
SYSTEM
1. Flare/Relief Valve
2. Flare/Relief Valve
TIME OF FLARING Black
Start Stop Duration Intermittent Smoke Planned VOLUME
10:20 10:25 OHrs 5Mins 0 0 ~ 135 MSCF
13:05 13:10 OHrs 5 Mins 0 0 ~ 14 MSCF
TOTAL VOLUME 149 MSCF
First Determination of Cause:
1. Shut down tic 1805 for maintainance
2. esd tic 1805 for maintainance
Action Taken to Stop Flaring:
1. Depressured unit
2. Depressured unit
Monday,December02.2002
Page 1 of 1
Facility
CENTRAL COMPRESSOR PLANT
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator Field(s) Month/Year of Disposition
BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 12/2002
Disposition Volume MCF*
1. Sold 2,767,184
2. Reinjected 230,123,144
3. Flared or vented less than 1 hour. 0
4. Flared or vented greater than 1 hour 0
(Supplemental report required - See 20 AAC 25.235)
5. Pilot and Purge 28,954
6. Used for lease operations Fuel 6,224,444
Assist 0
7. Other Lift Gas, Off Field 0
TOTAL items 1 - 7 239,143,726
8. NGL gas equivalent produced 0
9. Purchased gas 0
10. Transferred from: FS1, FS2, FS3, GC1, GC2, GC3 256,264,290
11. Transferred to: CGF 20,207,701
Remarks:
I hereby cer¿that tt fOregOin~rUe and correct to the best of my knowledge.
Signature: Iì, Å~ "'dl ~ Title: SUPERVISOR
Form 10-422 (Revised 4/95)
*Indicate contribution of each pool to total.
Pool Name Code Percent
PRUDHOE 640150 99.75%
PBU Midnight Sun Undefined 640158 0.25%
1. Safety
MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
Commissioner
Date
Note: All volumes must be corrected to pressure of 14.65
psia and to a temperature of 60 degrees F. Report due by
the 20th of the month following the month of disposition.
Authority 20 AAC 25.235.
SP EXPLORATION (ALASKA) INC.
PRUDHOE SAY UNIT - CENTRAL COMPRESSOR PLANT
GAS FLARING INCIDENT REPORT
December 2002
Page 1
~Unplanned Events less than or e9ual to 1 hour
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
TOTAL
o
JUnplanned Events greater than 1 hour
DATE TIME VOLUME
DESCRIPTION OF INCIDENT & CAUSE
See attachments
TOTAL
o
Jplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct
DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE
See attachments
TOTAL
o
~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mct
DATE: TIME: VOLUME: DE:SCRIPTION OF INCIDENT & CAUSE
See attachments
TOTAL
o
Unplanned Events < 1 Hour
Unplanned Events> 1 Hour
Planned Events < 1 hour and not
exceeding 5,000 MCF
Planned Events> 1 hour or
exceeding 5,000 MCF
Pilot Purge
Assist
o
o
o
o
TOTAL FLARED VOLUME
28,954
ACTION TAKEN TO ELIMINATE CAUSE
Not required for unplanned events which
are less than or equal to 1 hour
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
ACTION TAKEN TO ELIMINATE CAUSE
See attachments
f
~
~
1/10/2003
3:28 PM