Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU FS 2 / BP Exploration STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2002 FACILITY: PBU FS 2 OPERATOR: BP EXPLORATION (ALASKA) INC Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 01/2002 FLOW STATION 2 Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 180 4. Flared or vented greater than 1 hour 0 ,/ (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 19,696 6. Used for lease operations Fuel 829,023 Assist 8 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 848,907 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 403,551 11. Transferred to: CCP 21,336,631 Remarks: I hereby ce¡¿,të1 therregOing iSr[Ue and correct to the best of my knowledge. Signature: .. . 1.. A "'^~: 1. Title: SUPERVISOR Form 1 0-422 (Revised 4/95) 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date If) Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT JANUARY, 2002 Page 1 t lunPlanned Events less than or equal to 1 hour p1¥¡ra;........ '.' ························¡rfME:( ···································/V(;)L'uME:···············PE$Cftlf?'I1I(;)N/O!::iifNCJPENT/&:ß'AUSe 1/9/2002 1703-1804 77 Not required for unplanned events which 1/10/2002 1325-1327 3 are less than or equal to 1 hour 1/17/2002 1000-1002 2 1/17/2002 1006-1008 2 1/17/2002 1030-1032 1 1/21/2002 0743-0745 5 1/23/2002 1034-1037 30 1/23/2002 1040-1046 60 TOTAL 180 Iunplanned Events greater than 1 hour DATE TfME . . VOLUME DESCRIPTION OF INCIDENT&: CAUSE See attachments o TOTAL . ACTION TAKEN TO ELlMINATECAU$E ..' Not required for unplanned events whil are less than or equal to 1 hour , ACTION TAKEN TO ELIMINATE cAUSE See attachments Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met See attachments o TOTAL See attachments Planned Events Exceeding 1 Hour OR Exceeding 5000 Met See attachments o TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour & not exceeding 5,000 MCF Planned Events> 1 hour and exceeding 5,000 MCF Pilot Purge Assist o o o TOTAL FLARED VOLUME See attachments Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) I BP EXPLORATION, ALASKA I EASTERN OPERATING AREA-PBU FLOW STATION 2 Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 728 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 17,344 6. Used for lease operations Fuel 727,667 Assist 4 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 745,743 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 364,907 11. Transferred to: CCP 19,634,826 Remarks: I hereby ceV,L3t t~ foregoiI true and correct to the best of my knowledge. Signature: , . J . --^ '» Title: SUPERVISOR Form 1 0-422 (Revised 4/95) Month/Year of Disposition I 02/2002 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT FEBRUARY, 2002 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 2/1/2002 1334-1401 270 Not required for unplanned events which 2/4/2002 1117-1129 120 are less than or equal to 1 hour 2/4/2002 1131-1138 70 2/4/2002 1140-1157 170 2/7/2002 0809-0815 30 2/7/2002 0831-0833 16 2/18/2002 1118-1121 10 2/18/2002 1150-1153 15 2/18/2002 1232-1233 5 2/18/2002 2238-2240 6 2/19/2002 1043-1045 4 2/19/2002 1046-1051 10 2/19/2002 1058-1059 2 TOTAL 728 Page 1 lunplanned Events greater than 1 hour DATE TIME VOLUME ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events whic are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments j DESCRIPTION OF INCIDENT 8< CAUSE' See attachments o TOTAL , ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met DATE TIME VOLUM,E DESCRIPTION OF INCIDENT 8c CAUSE See attachments TOTAL 0 ACTION TAKEN TO ELIMINATE CAUSE See attachments ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL 0 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o 18,076 ~ ACTION TAKEN TO ELIMINATE CAUSE See attachments Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 03/2002 Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 134 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 19,284 6. Used for lease operations Fuel 822,488 Assist 152 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 842,058 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 402,900 11. Transferred to: CCP 20,966,498 Remarks: I hereby ce(J that thTIoregoing li~ true and correct to the best of my knowledge. Signature: . a . 1 j~.. ,. Title: SUPERVISOR Form 10-422 (Revised 4/95) 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT MARCH, 2002 Page 1 Unplanned Events less than or equal to 1 hour 3/17/2002 3/17/2002 3/18/2002 3/20/2002 3/21/2002 1147-1203 2138-2142 0028-0035 1740-1755 1406-1414 21 Not required for unplanned events which 8 are less than or equal to 1 hour 40 50 15 TOTAL 134 I Junplanned Events greater than 1 hour DATE TIME 'VOLUME', DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL 0 ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME' DESCRIPTION OF INCIDENT & CAUSE ' See attachments TOTAL 0 Not required for unplanned events whi, are less than or equal to 1 hour ACTIONTAIŒN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE , " See attachments I Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Met DATE TIME' 'vOLUME 'DESCRIPTIONOFINCIDENT &: CAUSE See attachments TOTAL 0 ACTION TAKEN TO ELIMINATE CAUSE See attachments I Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist 134 o o o TOTAL FLARED VOLUME 19,570 Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 04/2002 FLOW STATION 2 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 1,045 4. Flared or vented greater than 1 hour 322 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,801 6. Used for lease operations Fuel 783,146 Assist 226 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 803,540 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 391,828 11. Transferred to: CCP 20,408,119 Remarks: I hereby ce~t the f~9 is true and correct to the best of my knowledge. Signature: Þ ""-- Title: 8UrCnVI800 ~. ~ Form 10-422 (Revisetf 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety :3 z- -z.. MCF ~ 2. Lease Use MCF 3. Conserv. Purposes MCF ~ Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT April 2002 Page 1 tunPlanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 4/13/2002 0027-0034 15 Not required for unplanned events which 4/18/2002 0946-0958 120 are less than or equal to 1 hour 4/18/2002 1002-1009 70 4/18/2002 1013-1018 50 4/18/2002 1020-1220 200 Intermittent 4/23/2002 1727-1736 90 4/25/2002 1109-1133 240 4/26/2002 1805-1838 290 4/28/2002 1042-1059 170 TOTAL 1,245 IUnplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 4/26/2002 1315-1630 122 See attachments '-f f l 8/,;). ao 2... .;400 I I TOTAL ~ 3~Á.. Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist o ~3~ TOTAL FLARED VOLUME 20,394 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events whic are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments I bp REPORT NO: 02-0233 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 18 Apr 2002 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 09:46 09:58 OHrs 12 Mins ~ 0 0 120 MSCF 2. Flare/Relief Valve 10:02 10:09 OHrs 7Mins ~ 0 0 70 MSCF 3. Flare/Relief Valve 10:13 10:18 OHrs 5Mins ~ 0 0 50 MSCF 4. F/are/Relief Valve 10:20 12:20 2Hrs OMins ~ 0 0 200 MSCF TOTAL VOLUME 440 MSCF First Determination of Cause: 1. Backed out by gas transit system. 2. As Above 3. Depressured B-train HP seperator to do maintenance on the level control valve, L 14V. Action Taken to Stop Flaring: 1. Gas cuts made across the field by EOC. Cut wells 11-24, 3-24, and 11-18 at FS-2. 2. As above 3. Completed depressurization. Tuesday, April 30, 2002 Page 1 of 1 bp REPORT NO: 02-0260 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 26 Apr 2002 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 13:15 16:30 3 Hrs 15Mins Black Intermittent Smoke Planned o 0 ~ VOLUME 122 MSCF 122 MSCF TOTAL VOLUME First Determination at Cause: 1. Depressured 11 D commonline to fix leaking thermowell. Action Taken to Stop Flaring: 1. Completed depressure and performed maintenance. Calculations on file based upon start pressure of 600psig/120f and ending 0 psig/120f. Tuesday.ApnI30.2002 Page 1 of 1 Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU OS/2002 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 2,421 4. Flared or vented greater than 1 hour 378 / (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 20,288 6. Used for lease operations Fuel 701,666 Assist 440 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 725,193 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 341,045 11. Transferred to: CCP 18,881,494 Remarks: I hereby cert~ thõ ~hX foregoing is ;rue and correct to the best of my knowledge. Signature: . . ~ ~ "~A 1 Title: SUPERVISOR Form 1 0-422 (Revised 4/95) 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety ~78 MCF..::.Jl?L- 2. Lease Use MCF 3. Conserv. Purposes MCF ~~ Commiss~ner l 'C/1/ùr Date Note: All volumes must be corrected to pressure of 14.65 psia. and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· FS-2 GAS FLARING INCIDENT REPORT May 2002 Page 1 'unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCFlIPTIONOFINCIDENT8cCAUSE 5/5/2002 1321-1337 160 Not required for unplanned events which 5/6/2002 1221-1308 470 are less than or equal to 1 hour 5/8/2002 1432-1446 19 5/11/2002 1758-1822 10 5/11/2002 2059-2118 10 5/11/2002 2136-2156 7 5/16/2002 0822-0827 35 5/16/2002 0846-0901 104 5/24/2002 0030-0115 420 5/24/2002 0300-0400 328 5/24/2002 1120-1133 328 5/24/2002 1300-1330 350 5/24/2002 1400-1440 170 TOTAL 2,411 ~Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION ()F INCIDENT & CAUSE, See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DI;SCRIPTIOtfOF INCIDENT& CAUSE , 5/10/2002 2056-2111 10 See attachments TOTAL 10 ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mct , DATE TIME VOLUME DESCRIPTION OF INCIDENT &, CAUSE 5/29/2002 1700-1920 378 See attachments TOTAL 378 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o 10 378 23,527 ACTI,ONTA.KENTO'.ELIMINATE.CA.USE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKENTOELIMINATE,CAUSE ' See attachments 6/6/2002 1:00 PM bp REPORT NO: 02-0289 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 10 May 2002 TIME OF FLARING SYSTEM Start Stop Duration 1. Controlled Slowdow 20:56 21:11 OHrs 15Mins Black Intermittent Smoke o 0 TOTAL VOLUME ~ First Determination ot Cause: 1. SLOWDOWN OF TC-1804 PRIOR TO A WATERWASH IN THE A.M. Action Taken to Stop Flaring: 1. COMPLETED DEPRESSURING THE MACHINE ONLY Tuesday, May 28, 2002 Planned VOLUME 10 MSCF 10 MSCF Page 1 of 1 bp FACILITY: FS2 SYSTEM 1. Flare/Relief Valve REPORT NO: 02-0338 BPXA FLARE REPORT PRUDHOE BAY DATE: 29 May 2002 TIME OF FLARING Start Stop Duration 17:00 19:20 2 Hrs 20 Mins Black Intermittent Smoke Planned ~ 0 ~ TOTAL VOLUME First Determination of Cause: 1. Depressure of A train gas train for vessel repair and State required recertification. Action Taken to Stop Flaring: 1. Completed maintenance required for above. Sunday, June 02, 2002 VOLUME 378 MSCF 378 MSCF Page 1 of 1 FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 06/2002 Facility Disposition Volume MCF' 'Indicate contribution of each pool to total. 1. Sold o Pool Name Code Percent 2. Reinjected o PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 1,707 o 5. Pilot and Purge 20,119 6. Used for lease operations Fuel Assist 664,915 17 7. Other Lift Gas, Off Field o TOTAL items 1 - 7 686,758 1. Safety MCF 8. NGL gas equivalent produced o 2. Lease Use MCF 9. Purchased gas o 3. Conserv. Purposes MCF 10. Transferred from: CGF 20,189 Commissioner Date 11. Transferred to: CCP 18,458,613 Remarks: Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. I hereby ce BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· FS-2 GAS FLARING INCIDENT REPORT June 2002 Page 1 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 6/4/2002 2339-2356 150 Not required for unplanned events which 6/7/2002 2232-2235 10 are less than or equal to 1 hour 6/13/2002 1702-1719 111 6/13/2002 1722-1742 139 6/13/2002 2243-2255 83 6/14/2002 1136-1154 125 6/15/2002 1546-1559 83 6/25/2002 1311-1404 1 ,006 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL 1,707 ~Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist o o o TOTAL FLARED VOLUME 7/9/2002 11:07 AM 21,843 Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 07/2002 FLOW STATION 2 Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 316 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 19,837 6. Used for lease operations Fuel 733,865 Assist 12 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 754,030 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 175,251 11. Transferred to: CCP 18,489,443 Remarks: I hereby ceo. that tltforegOing ~, true and correct to the best of my knowledge. Signature: (} .J. .A '~11 Title: SUPERVISOR Form 10-422 (Revised 4/95) 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT July 2002 Page 1 Unplanned Events less than or equal to 1 hour 7/2/2002 7/10/2002 7/11/2002 7/23/2002 7/23/2002 7/27/2002 1947-2002 1128-1131 0956-1008 2012-2015 2221-2227 0730-0800 104 Not required for unplanned events which 21 are less than or equal to 1 hour 83 13 25 70 Not required for unplanned events which are less than or equal to 1 hour TOTAL 316 See attachments See attachments TOTAL o Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met See attachments See attachments TOTAL o Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist See attachments See attachments TOTAL o 316 o o o 8/8/2002 2:16 PM TOTAL FLARED VOLUME 20,165 Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 2,263 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 19,308 6. Used for lease operations Fuel 745,494 Assist 35 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 767,100 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 335,740 11. Transferred to: CCP 20,523,841 Remarks: I hereby certil?:5he tregOing is ~ue and correct to the best of my knowledge. Signature: .. . ~ J ....... 'ß. Title: SUPERVISOR Form 10-422 (Revised 4/95) ear of Disposition 08/2002 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT August 2002 Page 1 ~Unplanned Events less than or equal to 1 hour ."'/.];º~"!t!!;;...;. """""""';"';;:+"!tIMIË""""" , , """"':!tØ¡;;!iJ.MI;!,,;ºI;!~~j;{II1í! fIØI!J:Ø!?tl!!l~I~!!;l\tm:c~t~~~·++':,''," 8/4/2002 0106-0412 550 Not required for unplanned events which 8/4/2002 0625-0634 90 are less than or equal to 1 hour 8/4/2002 1320-1354 70 8/4/2002 2323-2332 90 8/5/2002 2211-2224 41 8/10/2002 0550-0608 180 8/13/2002 0744-0752 80 8/18/2002 2014-2017 15 8/21/2002 1944-1953 90 8/22/2002 1155-1208 130 8/23/2002 1009-1059 330 8/25/2002 1225-1238 130 8/25/2002 1503-1551 440 8/30/2002 1526-1553 27 TOTAL 2,263 ,',·ACTIi:)I\ITAKEIltT()E"'II\IItI\tATl;!þA!iJ.$E ;;" ' Not required for unplanned events which are less than or equal to 1 hour J ~Unplanned Events 9reater than 1 hour DATE '," TIME , ' , , VClLUME DESCRIPTIClNOFINCI )I;NT~CAUSE, See attachments , "'ACTIONTAKI;N TOI;LIMINA'TE9AUSE See attachments """" ,I TOTAL o Iplanned Events Less Than or Equal 1 Hour AND Not Exeeedin!¡J 5000 Met ...., . DArE " ";' .';; TIME;;; "", VOLUME; ."DESCÐIPTlON OF]NCIDEtfrli Ç'A'USE. Y'; ....,,'.. ." ,; .'... ,.AÇTlONTAKEI!J);OElJMINA'!£!.,CA'ü!ilE;,..,',' See attachments See attachments ...-..,-....-......,....,""',.....,..,.."... TOTAL o 1~1~,~~ed~v~~~.~xcee~i~~1~~ur~~~x~ee~ing 500~ "Met, '..""', "'" ",,; "I ·',',"""·DATIi;.':TIME'" """ : ',¥ClL i.!MI;' "',º~ÇBIP'TION'QJS"'NÇI!;i!eNT';~cAUSI;"'" ·"'·,+'·';AÇIl()I!J;."I"~~eNim!I()yt;1J \IIIf\I~m!I~.~A'I;1$e·.;·' See attachments See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o 21 ,606 9/11/2002 3:57 PM Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 09/2002 Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 616 4. Flared or vented greater than 1 hour 2,327 V (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,945 6. Used for lease operations Fuel 714,075 Assist 9 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 735,972 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 349,482 11. Transferred to: CCP 18,570,872 Remarks: I hereby cert~that th~e and correct to the best of my knowledge. Signature: ..Q. -'-- Title: SUPERVISOR Form 10-422 (Revised 4/95) 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety L( 'Jz 7 MCF (]Bte- 2. Lease Use MCF 3. Conserv. Purposes MCF ~~~/ ( ~';Y(()J- Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT September 2002 Page 1 Unplanned Events less than or equal to 1 hour 9/7/2002 9/8/2002 9/17/2002 9/17/2002 9/20/2002 9/23/2002 9/29/2002 Not required for unplanned events which are less than or equal to 1 hour 1607-1613 0539-0542 1525-1547 1659-1725 0117-0129 0401-0412 0925-0942 21 Not required for unplanned events which 10 are less than or equal to 1 hour 220 260 70 11 24 TOTAL 616 Unplanned Events greater than 1 hour 9/3/2002 9/3/2002 9/4/2002 9/4/2002 0441-0757 1945-2215 0237 -0411 1530-1920 681 See attachments 521 326 799 See attachments TOTAL 2,327 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mef See attachments See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist See attachments See attachments TOTAL o 2,327 o o 10/7/2002 1 :30 PM TOTAL FLARED VOLUME 21,897 bp REPORT NO: 02-0606 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 03 Sep 2002 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 04:41 07:57 3Hrs 16 Mins 0 0 0 681 MSCF 19:45 22:15 2 Hrs 30 Mins 0 0 0 521 MSCF TOTAL VOLUME 1 ,202 MSCF First Determination of Cause: 1. Spin cool 1804 for water wash and maintenance. 2. Spin cool 1803 for water wash and maintenance Action Taken to Stop Flaring: 1. Completed cooldown. Volume based upon 5mmscfd = 3472 per minute x 196 mins. 2. Completed cooling. Volume based upon 5mmscfd = 3472 x 150 mins. Wednesday, September 25, 2002 Page 1 of 1 bp REPORT NO: 02-0611 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 04 Sep 2002 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 02:37 04:11 1 Hrs 34Mins D D D 326 MSCF 15:30 19:20 3 Hrs 50 Mins D D D 799 MSCF TOTAL VOLUME 1,125 MSCF First Determination of Cause: 1. SPIN COOLING TC-1803 TO PREP FOR MAINTENANCE 2. SPIN COOLING TC-1804 TO PREP FOR MAINTENANCE Action Taken to Stop Flaring: 1. COMPLETED COOLING PERIOD 2. COMPLETED COOLING PERIOD Wednesday, September 25,2002 Page 1 of 1 Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 10/2002 Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 354 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 19,658 6. Used for lease operations Fuel 778,466 Assist 5 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 798,483 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 372,601 11. Transferred to: CCP 20,413,222 Remarks: I hereby celL that t fOr~!g is true and correct to the best of my knowledge. Signature: .0..Jvt ~ Title: SUPERVISOR Form 10-422 (Revised 4/95) 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· FS-2 GAS FLARING INCIDENT REPORT October 2002 Page 1 Iunplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OFINCIDENT&; CAUSE 10/1/2002 1937 -1941 8 Not required for unplanned events which 10/19/2002 0805-0809 40 are less than or equal to 1 hour 10/24/2002 1122-1206 306 , ACTION T.AKENTOELlMINATECAUSE ' Not required for unplanned events which are less than or equal to 1 hour ~ TOTAL 354 'Unplanned Events ~reater than 1 hour , , DATE ' TIME ' . VOLUME DESCRIPTION OF INCIDENT &;CAUSE See attachments " ACTION TAKEN TO ELIMINATE CAUSE See attachments ~ TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met DATE ' TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE, See attachments ,ACTION TAKEN TO ELfMINA Te CAUSE See attachments TOTAL o ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf , , DATE TIME ' , VOLUME DESCRIPTION OF INCIDENT 8c CAUSE, See attachments ACTIOþ, TAKEN TO ELIMINATE CAUSE See attachments I TOTAL 0 Unplanned Events < 1 Hour 354 Unplanned Events> 1 Hour 0 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events> 1 hour or 0 exceeding 5,000 MCF Pilot Purge Assist 1117/2002 3:16 PM TOTAL FLARED VOLUME 20,017 FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 11/2002 Facility Disposition Volume MCF' 'Indicate contribution of each pool to total. 1. Sold o Pool Name Code Percent 2. Reinjected o PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 1,804 4. Flared or vented greater than 1 hour (Supplemental report required - See 20 AAC 25.235) 837 5. Pilot and Purge 18,284 6. Used for lease operations Fuel Assist 722,011 44 7. Other Lift Gas, Off Field o TOTAL items 1 - 7 742,980 1. Safety 837 MCF OS~ 8. NGL gas equivalent produced o 2. Lease Use MCF 9. Purchased gas o 3. Conserv. Purposes MCF 10. Transferred from: CGF 334,732 -/ f,t1-/ù~ Date 11. Transferred to: CCP 19,383,708 I hereby cerJilr ~t th Signature: k·l1. Form 10-422 (Revised 4/95) true and correct to the best of my knowledge. Title: SUPERVISOR Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Remarks: SP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT· FS-2 GAS FLARING INCIDENT REPORT November 2002 Page 1 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTlONiOFINCIOENT:&:CAuSE 11/6/2002 2238-2304 181 Not required for unplanned events which 11/11/2002 0552-0606 97 are less than or equal to 1 hour 11/15/2002 0733-0742 90 11/15/2002 2234-2245 110 11/16/2002 0635-0643 80 11/16/2002 1148-1218 300 11/16/2002 1455-1548 290 11/16/2002 2234-2245 110 11/17/2002 2339-2355 160 11/18/2002 0900-0927 195 11/21/2002 2102-2118 111 11/22/2002 11 00-11 08 80 TOTAL 1,804 ~Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 11/3/2002 1422-1600 837 See attachments TOTAL 837 ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL 0 Unplanned Events < 1 Hour Unplanned Events> 1 Hour 837 Planned Events < 1 hour and not 0 exceeding 5.000 MCF Planned Events> 1 hour or 0 exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 20.969 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 12/9/2002 11:28AM REPORT NO: 02-0763 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 03 Nov 2002 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 14:22 16:00 1 Hrs 38 Mins Black Intermittent Smoke Planned o 0 o VOLUME 837 MSCF 837 MSCF TOTAL VOLUME First Determination ot Cause: 1. LEAKING GREASE FITTING AT DS3. DEPRESSURED 3C COMMONLlNE. BASED UPON 170 PSIG AT 150 deg 1. Action Taken to Stop Flaring: 1. shutin after finishing flaring Tuesday, November 26, 2002 Page 1 of 1 REPORT NO: 02-0809 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 15 Nov 2002 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 04:10 04:15 OHrs 5Mins Slack Intermittent Smoke Planned o 0 ~ VOLUME 3 MSCF 3 MSCF TOTAL VOLUME First Determination ot Cause: 1. Normal stop of 1802 T/C due to completion of hours required for a 4000 hour inspection. 1801 T/C was already on line. Action Taken to Stop Flaring: 1. 1802 T/C completed depressuring and is in a SIB mode. Tuesday,November26,2002 Page 1 of 1 Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 12/2002 Disposition Volume MCF' 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour 600 ,./ (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,655 6. Used for lease operations Fuel 830,644 Assist 8 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 849,907 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 378,253 11. Transferred to: CCP 21,512,689 Remarks: I hereby certiV~õ ~~ foregoing 1-< true and correct to the best of my knowledge. Signature: " À J AN\ l' Title: SUPERVISOR Form 10-422 (Revised 4/95) 'Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety bOO MCF ::}ßR 2. Lease Use MCF 3. Conserv. Purposes MCF ~~.* d/tO/05 Commi ioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT December 2002 Page 1 JUnplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL o IUnplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE 12/12/2012 0946-1117 600 See attachments TOTAL 600 ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE See attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o 600 o o 19,263 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 1/10/2003 3:32 PM FACILITY: FS2 SYSTEM 1. Flare/Relief Valve REPORT NO: 02-0867 BPXA FLARE REPORT PRUDHOE BAY DATE: 12 Dee 2002 TIME OF FLARING Start Stop Duration 09:46 11 :17 1 Hrs 31 Mins Black Intermittent Smoke Planned o 0 o TOTAL VOLUME First Determination ot Cause: 1. 16-1801 T/C shut down due to commpressor seal oil pump failure. Action Taken to Stop Flaring: 1. Restarted 1801 T/C. Note, delay in start up was due to fuel gas control valve problems. Thursday, December 26, 2002 VOLUME 600 MSCF 600 MSCF Page 1 of 1