Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU GC 2 / BP Exploration STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2002 FACILITY: PBU GC 2 OPERATOR: BP EXPLORATION (ALASKA) IN C GATHERING CENTER 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION perator ield(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 01/2002 acUity Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 766 4. Flared or vented greater than 1 hour 0 (Supplemental report reauired - See 20 AAC 25.235) 5. Pilot and Purge 23,372 6. Used for lease operations Fuel 678,694 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 702,832 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 21,632,946 Remarks: I hereby ce~at th~gOing is tX:::::d corQ to the best of my knowledge. Signature: . .. n._ R.", D.Qritle: SUPERVISOR Form 1 0-422 (Revì~ 4/95) v *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Date J';:7 Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Reþort due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-2 GAS FLARING INCIDENT REPORT JANUARY, 2002 Page 1 Iunplanned Events less than or equal to 1 hour . DATE .... TIME · VOLUME DESCRIPTION OF INCIDENT & CAUSE 1/24/2002 1128-1221 552 Not required for unplanned events which 1/26/2002 0117-0121 33 are less than or equal to 1 hour 1/26/2002 0427 -0432 49 1/26/2002 0634-0646 83 1/26/2002 0735-0742 49 ACTION TÄKEN TOpEL.lMINATECAUSE Not required for unplanned events which are less than or equal to 1 hour I TOTAL 766 IUnplanned Events greater than 1 hour DATE· .. TIME . VOLUME DESCRIPTION OF INCIDENT & CAUSE . See Attachments o . ACTION TAKEN TO ELlMINATISCAUSE See Attachments I TOTAL Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct See Attachments o See Attachments TOTAL Planned Events Exceeding 1 Hour OR Exceeding 5000 Mct See Attachments o See Attachments TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour & not exceeding 5,000 MCF Planned Events> 1 hour and exceeding 5,000 MCF Pilot Purge Assist 766 o o o TOTAL FLARED VOLUME Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 0212002 GATHERING CENTER 2 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 3,022 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 20,723 6. Used for lease operations Fuel 619,335 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 643,080 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 20,726,792 Remarks: I hereby cert()t~ðthìtregOing iSIÖ~e and correct to the best of my knowledge. Signature: .. ..Á.......A  Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-2 GAS FLARING INCIDENT REPORT FEBRUARY, 2002 Page 1 'unplanned Events less than or equal to 1 hour .. DATE.·.·.·· ···TIME· P VOLUME ....... DESCRIPTION OF INCIDENT & CAUSE· 2/1/2002 1335-1345 417 Not required for unplanned events which 2/4/2002 1115-1157 2,167 are less than or equal to 1 hour 2/4/2002 2113-2132 396 2/19/2002 0140-0144 42 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ~ TOTAL 3,022 IUnplanned Events greater than 1 hour ··.DATI!: . ... . TIME . ... VOLUMEDESCRIP.TIONOFUlCIDENT ~CAUSE . ...... See Attachments TOTAL 0 ~CTIONTAKi5N T(,l1;LlMtNATE CAUSE ......... See Attachments I Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct See Attachments o See Attachments TOTAL 'planned Events Exceeding 1 Hour OR Exceeding 5000 Mct .....1 . ...DATE .... . .... TIME .... .... . VOLUME . Di5SCRIPTIONOFINCIDENT& CAUSE .... . ... ACTION TAKEtI rOELlMItI ATE CAU~I!: See Attachments See Attachments TOTAL 0 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o 23,745 Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 03/2002 GATHERING CENTER 2 Disposition Volume MCF" 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 6,948 / 4. Flared or vented greater than 1 hour 10,694 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 24,179 6. Used for lease operations Fuel 669,517 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 . 7 711,338 / 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 22,193,068 Remarks: I herebY::~ð atæe fOregOi~ is true and correct to the best of my knowledge. Signature: . . 1 A 1\ '"'* ' I J Title: SUPERVISOR Form 10-422 (Revised 4/95) "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety 1(:) &FJt.f MCF IIJGA 2. Lease Use MCF 3. Conserv. Purposes MCF <l1~ /0 ð- Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-2 GAS FLARING INCIDENT REPORT MARCH, 2002 IUnplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 0301-02 1707-1719 58 Not required for unplanned events which 3/1/2002 1729-1755 181 are less than or equal to 1 hour 3/7/2002 2118-2150 375 3/14/2002 2334-2359 5,417 3/15/2002 0206-0227 146 3/16/2002 0937-0947 49 3/16/2002 2115-2118 15 3/17/2002 0322-0331 63 3/18/2002 1206-1226 56 3/21/2002 1633-1645 42 3/21/2002 2009-2017 56 3/22/2002 1621-1625 14 3/22/2002 2058-2105 49 3/22/2002 2314-2329 260 3/24/2002 0947-0951 167 Page 1 TOTAL 6,948 lunplanned Events greater than 1 hour DATE TIME 3/15/2002 0000-0117 VOLUME DESCRIPTION OF INCIDENT & CAUSE 10,694 See Attachments Intermittent 10,694 TOTAL ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See Attachments Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL 0 Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL 0 ACTION TAKEN TO ELIMINATE CAUSE See Attachments Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5.000 MCF Planned Events> 1 hour or exceeding 5.000 MCF Pilot Purge Assist TOTAL 6.948 10.694 o o TOTAL FLARED VOLUME 41,821 ACTION TAKEN TO ELIMINATE CAUSE See Attachments REPORT NO: 02-0144 BPXA FLARE REPORT PRUDHOE BAY FACILITY: GC2 DATE: 15 Mar 2002 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 00:00 01:17 1 Hrs 17 Mins 0 0 0 10,694 MSCF 02:06 02:27 OHrs 21 Mins 0 0 0 146 MSCF TOTAL VOLUME 10,840 MSCF First Determination ot Cause: 1. lPS compressor K-7000 shut down because of control/instrumentation failure associated with the seal oil differential pressure switch. 2. lPS compressor K-7000 shut down because of control/instrumentation failure associated with the seal oil differential pressure switch. Action Taken to Stop Flaring: 1. WOA reduced production rates and shut-in lP wells equaling 266mmscfd. Wells were shut-in or choked back starting at 00:00 hours. 2. WOA reduced production rates and shut-in lP wells equaling 10 mmscfd. Wells were shut-in or choked back starting at 02:06 hours. Thursday, March 28, 2002 Page 1 of 1 GPB Flaring incident Subject: GPB Flaring incident Date: Mon, 18 Mar 200215:43:14 -0600 From: "Bolkovatz, Mike J" <BolkovMJ@BP.com> To: "'Steve McMains (E-mail)...<steve_mcmains@admin.state.ak.us> CC: "Fiedler, Anne M" <FiedleAM@BP.com>, "Benson, Gary A" <BensonGA@BP.com>, "Pfeiffer, Jim A" <PfeiffJA@BP.com>, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast@BP.com> > To: > > > > From: > > This note is to inform you of a flaring incident which occurred on March > 15, 2002. At midnight, GC2 started flaring > because LPS compressor K-7000 shutdown due to an instrumentation failure > associated with the seal oil differential pressure switch. 266 MM/D gas was immediately shutin to reduce the slugcatcher pressure below its flare limit. The flare valve did not reseat for 1 hr and 17 minutes, and a total of 10,694 MSCF was flared. > Please don't hesitate to call me with any questions. > > > > > Steve McMains, AOGCC steve mcmains@admin.state.ak.us 907-793-1241, fax 907-276-7542 Michael Bolkovatz, GPB Prod Optim Team Leader, 907-659-5566 Michael Bolkovatz GPB Production Optimization TL 659-5566 1 of 1 3/18/02 12:47 PM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 04/2002 GATHERING CENTER 2 Form 10-422 (Revised 4/95) "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety ~ 33 MCF -...J.ßI'Z-- Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 2,135 /' 4. Flared or vented greater than 1 hour 833 ./ (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 22,685 6. Used for lease operations Fuel 521,777 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 547,430 / 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 17,419,930 Remarks: I hereby certC!.hñ the tregOing is tr and correct to the best of my knowledge. Signature:. .Á . A .^. h Title: SUPERVISOR 2. Lease Use MCF 3. Conserv. Purposes MCF (~~. t;,L.-A/Gi' Commissi~er 0 (P!iO 10 ;r Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-2 GAS FLARING INCIDENT REPORT April 2002 Page 1 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT &. CAUSE 4/8/2002 1114-1122 250 Not required for unplanned events which 4/11/2002 1500-1505 69 are less than or equal to 1 hour 4/13/2002 0432-0450 625 4/13/2002 0734-0833 1,024 4/26/2002 1546-1551 56 TOTAL 2,024 ~Unplanned Events greater than 1 hour DATE TIME 4/8/2002 2136-2336 VOLUME DESCRIPTION OF INCIDENT &. CAUSE 833 See Attachments Intermittent 833 TOTAL ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT &. CAUSE 4/2/2002 1225-1442 111 See Attachments ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See Attachments TOTAL 111 IPlanned Events Exceeding 1 Hour OR Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT &. CAUSE See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist 833 111 o TOTAL FLARED VOLUME 25,653 ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments bp FACILITY: GC2 SYSTEM 1. Flare/Relief Valve REPORT NO: 02-0191 BPXA FLARE REPORT PRUDHOE BAY DATE: 02 Apr 2002 TIME OF FLARING Start Stop Duration 12:25 14:42 0 Hrs 16Mins Black Intermittent Smoke ~ 0 Planned TOTAL VOLUME ~ First Determination of Cause: 1. LPS compressor K-7000 shut down for exhaust stack repair Action Taken to Stop Flaring: 1. All LP wells to GC-2 cut back to minimum Tuesday,ApriI30,2002 VOLUME 111 MSCF 111 MSCF Page 1 of 1 REPORT NO: 02-0213 BPXA FLARE REPORT PRUDHOE BAY FACILITY: GC2 DATE: 08 Apr 2002 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 11:14 11:22 OHrs 8Mins D D D 250 MSCF 21:36 23:36 2Hrs OMins ~ D D 833 MSCF TOTAL VOLUME 1,083 MSCF First Determination of Cause: 1. High ambient temperature swings resulted in flaring and required cuts in production. Ambient temperature increased by 7°F. 2. LPS compressor K-7001 shut down due to a problem associated with seal oil leakage. Action Taken to Stop Flaring: 1. WOA reduced production rates and shut-in 6 wells equaling 25 mmscfd. Wells were shut-in or choked back starting at 1115 hours. 2. WOA stopped bringing production rates up until wells unloaded and flaring was ceased. 3 intermittent incidents. 2136 to 2148 2149 to 2204 2312 to 2336 all about the same rate. Tuesday, April 30, 2002 Page 1 of 1 Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU GATHERING CENTER 2 Disposition Volume MCF" 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 2,479 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 22,325 6. Used for lease operations Fuel 621,002 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 645,806 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 19,996,337 Remarks: I hereby certi~t~Qtheloregoing i~drue and correct to the best of my knowledge. Signature: . ..A. .A .. A""'. 1. I Title: SUPERVISOR Form 10-422 (Revised 4/95) ear of Disposition OS/2002 "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 1 00.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BA V UNIT - GC-2 GAS FLARING INCIDENT REPORT May 2002 Page 1 Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 5/9/2002 0245-0306 292 Not required for unplanned events which 5/12/2002 0312-0334 139 are less than or equal to 1 hour 5/12/2002 0358-0408 69 5/16/2002 0422-0447 260 5/24/2002 1436-1441 56 5/24/2002 1519·1528 106 5/24/2002 1657·1702 52 5/24/2002 1730-1832 285 Intermittent - 41 minutes 5/29/2002 1741-1826 938 5/31/2002 0015-0102 83 5/31/2002 0705·0807 199 Intermittent· 26 minutes TOTAL 2,479 'Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments Intermittent o TOTAL ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments Planned Events Less Than or Equal 1 Hour AND Not Exceedln 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o ACTION TAKEN TO ELIMINATE CAUSE See Attachments Planned Events Exceedln 1 Hour OR Exeeedin 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME TOTAL 2,479 o o o 24,804 6/6/2002 1:03 PM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 06/2002 GATHERING CENTER 2 Disposition Volume MCF" 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 1,152 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 20,295 6. Used for lease operations Fuel 601,944 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 623,391 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 19,726,877 Remarks: I hereby certify that Re fOregOin1iS true and correct to the best of my knowledge. Signature: 0·0. ..Á. A A .J\.L J, Title: SUPERVISOR Form 10-422 (RevIsed 4/95) "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-2 GAS FLARING INCIDENT REPORT June 2002 Page 1 ¡unplanned Events less than or equal to 1 hour [)~II: . TIME···· . "QLUM.EPIË$¢RIP"'I()I\I()FIN¢IPf:I\I, "~¢At.J$lËi 6/1/2002 0722-0727 31 Not required for unplanned events which 6/4/2002 1056-1246 258 are less than or equal to 1 hour 6/15/2002 1 036-1126 400 6/20/2002 0339-0344 35 6/23/2002 0833-0841 78 6/24/2002 0755-0802 68 6/25/2002 0338·0404 126 6/25/2002 1527-1543 156 TOTAL 1,152 ¡unPlanned Events greater than 1 hour .·DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE· See Attachments Intermittent o TOTAL ACTIONTAI<EN TQ .ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE· . See Attachments ¡Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct . . DATE TIME VOLUME.· DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mct . DATE .. TIME . . VOLUME . DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 1,152 o o o 21,447 ACTION TAKEN TO ELIMINATE CAUSE. See Attachments . . ACTION TAKEN TO ELIMINATE CAUSE . See Attachments 7/9/2002 10:50 AM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU GATHERING CENTER 2 Disposition Volume MCF" 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 258 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 19,345 6. Used for lease operations Fuel 551,082 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 570,685 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 20,368,137 Remarks: I hereby ce~ t}~ tr fOregOin~oS true and correct to the best of my knowledge. Signature:. 1.J..... 0 J Title: SUPERVISOR Form 10-422 (Revised 4/95) Month/Year of Disposition 07/2002 "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT· GC·2 GAS FLARING INCIDENT REPORT July 2002 Page 1 Unplanned Events less than or equal to 1 hour 7/4/2002 7/26/2002 7/26/2002 1556-1600 0646-0655 2149-2201 28 Not required for unplanned events which 63 are less than or equal to 1 hour 167 Not required for unplanned events which are less than or equal to 1 hour TOTAL 258 See Attachments Intermittent o See Attachments TOTAL Planned Events Less Than or Equal 1 Hour AND Not Exceedin See Attachments See Attachments TOTAL o Planned Events Exceeding 1 Hour OR Exceedin See Attachments See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 258 o o o 19,603 8/12/2002 2:43 PM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU GATHERING CENTER 2 Disposition Volume MCF" 1. Sold 2. Reinjected o o 3. Flared or vented less than 1 hour. 3,595 4. Flared or vented greater than 1 hour (Su lemental report required - See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations 7. Other 8. NGL gas equivalent produced 9. Purchased gas 10. Transferred from: 11. Transferred to: CCP Remarks: 394 20,391 Fuel Assist 590,132 o Lift Gas, Off Field o TOTAL items 1 - 7 614,512 o o o 20,731,435 I hereby cert' Signature: Form 10-422 (Revised 4/95) Title: SUPERVISOR "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety .3t4» MCF ~ 2. Lease Use MCF 3. Conserv. Purposes MCF ~.~ \/2(,,/0 :>- Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUOHOE BAY UNIT - GC-2 GAS FLARING INCIOENT REPORT August 2002 Page 1 ual to 1 hour 8/3/2002 8/5/2002 8/6/2002 8/7/2002 8/8/2002 r&/9/2002 U8/10/2OO2 8/10/2002 8/10/2002 8/14/2002 8/16/2002 8/16/2002 8/19/2002 8/20/2002 8/20/2002 8/27/2002 8/30/2002 8/31/2002 8/31/2002 181 Not events which 69 are less than or equal to 1 hour 125 33 63 140 50r 270 150 260 106 229 139 84 700 347 250 52 156 191 Not for events are less than or equal to 1 hour 1034-1054 2314-2332 0915-0919 0243-0252 0136-0156 -:z358:2400 0001-0033 0202-0224 0458-0537 1638-1655 0157-0219 1737-1757 1427-1438 1356-1432 1742-1832 0927-0948 1135-1140 1012-1021 1235-1246 ¡"Sl.~ß''c~.j- "~,~~-\O ck.\er-;'~I\t ~F ~ ~ I <:;I~ ~'€t t:-: j'Ç 5." ~ì..;~,.kv Iøi:' ir'\C(..u.;leg r.{ç (- 1412- ~ Úß12- TOTAL 3,595 IUnplanned Events greater than 1 hour '".O)\Te· '·TI",e ',V9lUME ·1>ej;C/JfPTJØN'Of"lNeJO~&ç:AUSe· 8/15/2002 0433-0544 394 See Attachments Intermittent TOTAL 394 ·ÄÇTlON TAtœ.f:I TpeWMIItATj;'Ci\,USE; ."". See Attachments IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Met , '·DATE . TIME .. u 'u:VQlUMS·, P!~RIPT!()Jj};~!"!I!I:CII,),I!t"'FIiR~US¡:¡" /'CA,CTIOII TAKEII TI)'ELJMINATECAUSE':uU See Attachments See Attachments TOTAL o ¡Planned Events Exceeding 1 Hour OR Exceedin~ 5000 Met , DATE ·u .,. uTIME..' "VOlUM! DI!SCRII'fION:OF'INCI¡¡!NHi:CAUSI;,u See Attachments Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME .,. /!..CTlON'TA~EN TOEl;lMINATJi;CAtJS!., . See Attachments I TOTAL o 394 o o 24,380 9/1112002 3:01 PM REPORT NO: 02-0554 BPXA FLARE REPORT PRUDHOE BAY FACILITY: GC2 DATE: 15 Aug 2002 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 04:33 05:44 1 Hrs 11 Mins Black Intermittent Smoke Planned o 0 o VOLUME 394 MSCF 394 MSCF TOTAL VOLUME First Determination of Cause: 1. High gas transit line pressure, ambient air temperature 48 degrees, too much gas for current ambient air temperature. Action Taken to Stop Flaring: 1. WOA reduced production rates and shut-in 6 wells equaling 100 mmscfd. Wells were shut-in or choked back starting at 04:34 hours. EOA shut-in 100 mmscfd at 05:31 hrs. VVednesday, August 21, 2002 Page 1 of 1 OPB Flaring Incident Subject: GPB Flaring Incident Date: Fri, 16 Aug 2002 21 :41 :30 -0500 From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com> To: 'steve _ mcmains@admin.state.ak.us' CC: "Fiedler, Anne M" <Fied1eAM@BP.com>, "Benson, Gary A" <BensonGA@BP.com>, "Pfeiffer, Jim A" <PfeiffJA@BP.com>, "GPB, Environ Advisor West" <GPBEnvironAdvisorWest@BP.com> > > > > > > Leader, 907-659-4472 > > > > > > > > > > > > > > > > To: Steve McMains, AOGCC steve mcmains@admin.state.ak.us 907-793-1241, fax 907-276-7542 From: Michael Bolkovatz, GPB Prod Optim Team This note is to inform you of an extended flaring incident at GC2. On August 15, starting at 04:33, the ambient temperature starting increasing at a higher than normal rate. This caused a higher than allowable gas transit line pressure and GC2 flare valve opened. Wells totaling 100 MSCFPD were immediately SI on the WOA, and an additional 100 MMSCFPD was SI on the EOA at 05:31 when the flare valve did not reseat. This was enough rate cut/pressure decrease to reseat the flare valve at GC2 at 05:44. A total of 394 MSCF was flared over this 1 hr, 11 min period. If you require additional information, please don't hesitate to call me. Michael Bolkovatz GPB Production Optimization TL 659-5566, 659-4472 1 of 1 8/19/20027:26 AM GATHERING CENTER 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 09/2002 Facility Disposition Volume MCF" "Indicate contribution of each pool to total. 1. Sold o Pool Name Code Percent 2. Reinjected o PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 3,047 4. Flared or vented greater than 1 hour (Supplemental report required - See 20 AAC 25.235) o 5. Pilot and Purge 18,202 6. Used for lease operations Fuel Assist 353,710 o 7. Other Lift Gas, Off Field o TOTAL items 1 - 7 374,959 1. Safety MCF 8. NGL gas equivalent produced o 2. Lease Use MCF 9. Purchased gas o 3. Conserv. Purposes MCF 10. Transferred from: o Commissioner Date 11. Transferred to: CCP 11 ,304,169 I hereby certi?í that t Signature: 1<.. I Form 10-422 (Revised 4/9 ) foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Remarks: Title: SUPERVISOR BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· GC-2 GAS FLARING INCIDENT REPORT September 2002 Page 1 IUnplanned Events less than or equal to 1 hour DATE TIM ¡ VoLUME DESC¡:UPTIONOF INCIDEN'J1 8< CAUsE 9/2/2002 1241·1250 63 Not required for unplanned events which 9/4/2002 0917-0933 111 are less than or equal to 1 hour 9/4/2002 0939-0954 94 9/4/2002 1500-1556 417 9/4/2002 1619-1640 146 9/5/2002 0250-0306 111 9/5/2002 1 028-1 044 133 9/5/2002 1245-1258 90 9/5/2002 1341-1416 243 9/512002 1930-1935 17 9/5/2002 2233·2240 24 9/6/2002 0000-0019 264 9/6/2002 1307-1326 198 9/7/2002 0545-061 0 521 9/7/2002 1128-1134 63 9/7/2002 11 49-1204 156 9/10/2002 0835-0856 292 9/12/2002 1016-1031 104 TOTAL 3,047 IUn¡>lanned Events greater than 1 hour DATE TIME VOLUME ACTION TAKEN TO· ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour DESCRIPTION OF INCIDENT 8< CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments TOTAL o ACTION TAKEN TO ELIMINATE CAUSE See Attachments IPlanned Events Less Than or Equal 1 Hour AND Not ExeeedinQ 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o ACTION TAKEN TO ELIMINATE CAUSE See Attachments ¡Planned Events Exeeedin\l1 Hour OR Exeeedin~ 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5.000 MCF Planned Events> 1 hour or exceeding 5.000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o 21,249 10/412002 2:31 PM GATHERING CENTER 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 10/2002 Facility Disposition Volume MCF" "Indicate contribution of each pool to total. 1. Sold o Pool Name Code Percent 2. Reinjected o PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 1,087 4. Flared or vented greater than 1 hour (Supplemental report required - See 20 AAC 25.235) 5,165 5. Pilot and Purge 24,124 6. Used for lease operations Fuel Assist 629,336 o 7. Other Lift Gas, Off Field o TOTAL items 1 - 7 659,712 1. Safety 5;16S MCF .y~_ 8. NGL gas equivalent produced o 2. Lease Use MCF 9. Purchased gas o 3. Conserv. Purposes MCF 10. Transferred from: o ~~ tD..J.,,¡: !fi,t" CommisGoner \~L ?> \ 0 .)- Date 11. Transferred to: CCP 19,666,777 I ~erebY cerpty V\at Signature: K U, Form 10-422 (Revised 4/95) is true and correct to the best of my knowledge. Title: SUPERVISOR Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Remarks: BP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT - GC-2 GAS FLARING INCIDENT REPORT October 2002 lunplanned Events less than or equal to 1 hour DATE TIME VOLuME DESCRIPTIONOFINCIDENrllrCAUSE 10/1/2002 1842-1847 35 Not required for unplanned events which 10/1/2002 2217-2222 17 are less than or equal to 1 hour 10/2/2002 0458-0502 28 10/6/2002 2141-2150 88 10/7/2002 0504-0528 267 10/7/2002 2133-2145 125 10/7/2002 2158-2208 125 10/8/2002 0417-0424 58 10/9/2002 0142-0152 69 10/23/2002 1307-1316 94 10/30/2002 2319-2332 181 Page 1 TOTAL 1,087 lunplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/3/2002 0740-0847 5,165 See Attachments TOTAL 5,165 Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTlONOflNCIOENT & CAUSE See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME TOTAL 1,087 5,165 o o 30,376 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments 11/13/2002 2:16PM REPORT NO: 02-0694 BPXA FLARE REPORT PRUDHOE BAY FACILITY: GC2 DATE: 03 Oct 2002 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 0140 0&41 1 Hrs 7Mins Black Intermittent Smoke o 0 Planned VOLUME o 5,165 MSCF TOTAL VOLUME 5,165 MSCF First Determination of Cause: 1. K-7000 LPS compressor sid. Action Taken to Stop Flaring: 1. Choked all LP wells that could be choked back remotly. Friday, October 25, 2002 Page 1 of 1 Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION perator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 11/2002 GATHERING CENTER 2 Disposition Volume MCF" 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 6,030 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 26,483 6. Used for lease operations Fuel 582,500 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 615,013 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 19,058,340 Remarks: I hereby cert~.thðte tregOing isp~e and correct to the best of my knowledge. Signature: . , .J A../7\ h Title: SUPERVISOR Form 10-422 (Revised 4/95) "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-2 GAS FLARING INCIDENT REPORT November 2002 Page 1 lunPlanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION .OFHNCIDENT&CAUSE 11/1/2002 1935-1955 486 Not required for unplanned events which 11/6/2002 1439-1517 3,958 are less than or equal to 1 hour 11/6/2002 2129-2136 15 11/7/2002 1548-1615 206 11/9/2002 1610-1700 417 11/10/2002 0240-0248 78 11/10/2002 0344-0356 117 11/16/2002 1157-1214 177 11/17/2002 0815-0843 311 11/24/2002 1449-1455 63 11/24/2002 1639-1704 174 Intermittent 11/25/2002 1755-1759 28 TOTAL 6,030 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour lunplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o ACTION TAKEN TO ELIMINATE CAUSE See Attachments IPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT.,. CAUSE See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o 32,513 ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments 12/9/2002 11:10AM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA WESTERN OPERATING AREA-PBU 12/2002 GATHERING CENTER 2 Disposition Volume MCF" 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 1,612 4. Flared or vented greater than 1 hour 2,813 /' (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 24,877 6. Used for lease operations Fuel 676,525 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 705,827 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: 0 11. Transferred to: CCP 21,107,311 Remarks: I hereby ceU~athe fOregO~g is true and correct to the best of my knowledge. Signature: J . ..... a.. Title: SUPERVISOR Form 10-422 (Revised 4/95) "Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety :; ß 13 MCF <YiJ2- 2. Lease Use MCF 3. Conserv. Purposes MCF d/¡ð!o3 Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC-2 GAS FLARING INCIDENT REPORT December 2002 Page 1 lunplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTJON OFJNCIDENT& CAUSE 12/7/2002 2306-2311 35 Not required for unplanned events which 12/8/2002 0246-0253 97 are less than or equal to 1 hour 12/15/2002 2341-2400 1,319 12/23/2002 1442-1448 42 12/24/2002 0454-0502 28 12/24/2002 1817·1834 56 1225-02 2223-2228 35 TOTAL 1,612 IUnplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 12/16/2002 0000-0121 2,813 See Attachments TOTAL 2,813 Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See Attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTIONOFfNCIDENT & CAUSE See Attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL 1,612 2,813 o o TOTAL FLARED VOLUME 29,302 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments ACTION TAKEN TO ELIMINATE CAUSE See Attachments 1/10/2003 3:18 PM REPORT NO: 02-0875 BPXA FLARE REPORT PRUDHOE BAY FACILITY: GC2 DATE: 16 Dee 2002 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 00:00 01 :21 1 Hrs 21 Mins Black Intermittent Smoke D D Planned VOLUME D 2,813 MSCF TOTAL VOLUME 2,813 MSCF First Determination of Cause: 1. LPS compressor K-7000 shut down because of control/instrumentation failure associated with a faulty power supply. Action Taken to Stop Flaring: 1. WOA reduced production rates and shut-in 34 wells equaling 250mmscfd. Wells were shut-in or choked back starting at 23:42 hours.(12/15) Thursday, December 26, 2002 Page 1 of 1