Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutBadami / BP Exploration STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2003 FACILITY: Badami OPERATOR: BP EXPLORATION (ALASKA) IN C · ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Field(s) Badami Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 333,590 3. Flared or vented less than 1 hour 415 4. Flared or vented greater than 1 hour 1,823 ¡/ (Supplemental report required-oSee 20 AAC 25.235) 5. Pilot and Purge 403 6. Used for lease operations Assist 0 Fuel 38 828 7. Other TOTAL items 1-7 375,059 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: is true and correct to the best of my knowledge. Title Me. tl -r A)( Date 2/,..1/03 Form 1 0-422 Rev. 4/95 Month/Year of Disposition Jan-03 *Indicate contribution of each pool to total. Pool Name voae Percent 60100 1 . Safety q b(p MCF 5ßp- $567 MCF 2. Lease 3. Conserv. Purposes MCF /L¿~/ ~__P4-~ ó5(~/a; Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 2/13/2003 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - BADAMI January-03 .. Page 1 Unplanned Events less than or equal to 1 hour TOTAL 378 Not required for unplanned events which are less than or equal to 1 hour Not required for unplanned events which are less than or equal to 1 hour 1/16/2003 62 Excessive gas flashed off gas boot separator due to low temperatures restarting plant after pipeline SID. 1542-1648 TOTAL 62 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf Pipeline asket job, vent line Flared depressuring 1GB for safeout. Flared depressuring 1GB for safeout. 1/15/2003 Pipeline gasket job, vent line De-pressure sales oil pipeline after leak testing with gas following gasket replacement. De-pressuring the Badami pipeline after leak checking the flange gaskets that had been recently replaced 0000-0730 554 -L TOTAL 1,~ I1Q <:1 ßf!- Volume flared less than 1 hour 4.1-5 "5l5' ¡J.e-- 1~ /2A3 56!!- Volume flared greater than 1 hour Pilot Purge 403 Assist Gas º TOTAL FLARED VOLUME 2,641 Turned on Production Heater and brought on warmer wells. De-pressure pipeline Per procedure IG is depressured to flare. Per procedure IG is depressured to flare. De-pressure pipeline Planned maintenance flaring Pipeline completely de-pressured ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 104,462 3. Flared or vented less than 1 hour 168 4. Flared or vented greater than 1 hour 0 (Supplemental report required-oSee 20 AAC 25.235) 5. Pilot and PurQe 364 6. Used for lease operations Assist 0 Fuel 33 555 7. Other TOTAL items 1-7 138,549 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: I hereby certi"that the f regoing is true and correct to the best of my knowledge. Signature (l O. Title M,,(2..-rA)C Date 3/'-40). Form 10-422 Rev. 4/95 MonthlY ear of Disposition Feb-03 *Indicate contribution of each pool to total. Pool Name lioae Percent 60100 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 3/5/2003 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - BADAMI February-03 Page 1 (unPlanned Events less than or equal to 1 hour . DATE TIME VOLUME ... TOTAL 166 [)ESCRIPTlON OF INCIDENT & CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELlMINAl'Ë CAUSE Not required for unplanned events which are less than or equal to 1 hour lunplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE TOTAL o Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf 2/27/2003 2006-2012 TOTAL 2 2 Bled IG compressor down for maintenance Repairs to compressor complete. Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf TOTAL o Volume flared less than 1 hour 168 Volume flared greater than 0 1 hour Pilot Purge 364 Assist Gas º TOTAL FLARED VOLUME 532 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Disposition 1. Sold 2. Reinjected 3. Flared or vented less than 1 hour 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations 7. Other TOTAL items 1-7 8. NGL gas equivalent produced 9. Purchased gas 10. Transferred from: 11. Transferred to: Operator BP Exploration (Alaska) Inc. Field(s) Badami Volume MCF* Fuel NGL o o 554,361 238 551 403 Assist Fuel o 48 825 604,378 o o from Endicott included in above dis ositions Signature Title (Yt 6 fL, ¡A X Date Y, 0 Form 1 0-422 Rev. 4/95 MonthlYear of Disposition Mar-03 *Indicate contribution of each pool to total. Pool Name 0 e 60100 Percent 1 . Safety 551 MCF 3ßß- 2. Lease MCF 3. Conserv. Purposes MCF ~~~~ S(~IO) Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 4/7/2003 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - BADAMI March-03 Page 1 ~Unplanned Events less than or equal to 1 hour DATE .... . TIME VOLUME ..' . ... TOTAL 210 ·DESCRIÞTIONOF INCIDENT &iCAUSE ... Not required for unplanned events which are less than or equal to 1 hour . ACTION TAKEN TO EUMINATECAU$E Not required for unplanned events which are less than or equal to 1 hour 3/9/2003 1024-1942 551 VRU compressor Shutdown due freezing in the cooling bays Thawed cooling bay with indirect fired heater and re- resulting in unit shutdown. started VRU TOTAL 551 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf 3/31/2003 3/23/2003 1412-1424 0906-0912 TOTAL 27 1 28 Shut IG-B shut. Depressured to flare for maintenance. VRU shut down for Maintenance Repairs done, IG-B back on line Performed maintenace and restarted. Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE · '.' TIME . VOLUME ." DËSCRIPl'lON OF INCIDENT & CAUSE . .. ACTION TAKEN TOELlMINAl'E CAUSE ..... .....".........,.,........."....__nn_........"".,',,._......._,...........,_.,.__._,.,_,_,........'_._n..._._.............'.._._n_._............,.._.__._.__._........ TOTAL o Volume flared less than 1 hour 238 Volume flared greater than 551 1 hour Pilot Purge 403 Assist Gas º TOTAL FLARED VOLUME 1,192 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Field(s) Badami Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 572,773 3. Flared or vented less than 1 hour 427 4. Flared or vented greater than 1 hour 116 ./ (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 390 6. Used for lease operations Assist 0 Fuel 47812 7. Other TOTAL items 1-7 621,518 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: Signature Title YJ1.6CL "'fA-x Date Form 1 0-422 Rev. 4/95 *Indicate contribution of each pool to total. Pool Name llioae Percent 60100 1. Safety {I¥' MCF :J~ 2. Lease MCF 3. Conserv. Purposes MCF ;f.c¥ '-4..~ - /)3 Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. 5/12/2003 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - BADAMI April-03 Page 1 IUnplanned Events less than or equal to 1 hour DATE TIME VOLUME TOTAL 427 DESCRIPTION OF INCIDENT & CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour lunplanned Events greater than 1 hour DATE TIME VOLUME 4/8/2003 0624-0854 116 TOTAL 116 DESCRIPTION OF INCIDENT & CAUSE Plant shut down in process of starting back up ACTION TAKEN TO EUMINATE CAUSE Restart plant and pertinent equipment Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO EUMINATE CAUSE TOTAL o Volume flared less than 1 hour 427 Volume flared greater than 116 1 hour Pilot Purge 390 Assist Gas º TOTAL FLARED VOLUME 933 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Operator BP Exploration Alaska) Inc. Field(s) Badami 3. Flared or vented less than 1 hour 123 *Indicate contribution of each pool to total. Pool Name llioae Percent 60100 Disposition Volume MCF* 1. Sold Fuel NGL o o 576,178 2. Reinjected 4. Flared or vented greater than 1 hour (Supplemental report required--See 20 AAC 25.235) 522 5. Pilot and Purge 403 6. Used for lease operations Assist Fuel o 50 250 1. Safety o?z.-z- MCF SfM'- 7. Other 2. Lease MCF TOTAL items 1-7 627,476 3. Conserv. Purposes MCF 8. NGL gas equivalent produced o 9. Purchased gas o from Endicott included in above dis ositions 10. Transferred from: 11. Transferred to: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature (2. Title Y'I1,ú iZ., í A)(' Date CQ 110 (C) "). Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. Form 10-422 Rev. 4/95 , > . 6/5/2003 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - BADAMI May-03 Page 1 Unplanned Events less than or equal to 1 hour TOTAL 123 Not required for unplanned events which are less than or equal to 1 hour Not required for unplanned events which are less than or equal to 1 hour 5/14/2003 2100-2236 TOTAL 522 522 Plant shutdown due to spurious input signal Re-start Plant Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf TOTAL o Planned Events Exceeding 1 Hour OR Exceeding 5000 Mef TOTAL o Volume flared less than 1 hour 123 Volume flared greater than 522 1 hour Pilot Purge 403 Assist Gas º TOTAL FLARED VOLUME 1,048 .. .. ..- " ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Operator BP Exploration Field(s) Badami MonthlYear of Disposition Jun-03 Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold Fuel NGL o o 584,758 Pool Name 0 e 60100 Percent 2. Reinjected 3. Flared or vented less than 1 hour 606 4. Flared or vented greater than 1 hour (Supplemental report required-oSee 20 AAC 25.235) 52 1. Safety 6" 7-MCF .3Brz- 5. Pilot and Purge 390 6. Used for lease operations Assist Fuel o 46 949 7. Other 2. Lease MCF TOTAL items 1-7 632,755 8. NGL gas equivalent produced o MCF 9. Purchased gas o from Endicott included in above dis ositions 7!?/þ ate 10. Transferred from: 11. Transferred to: I hereby certify that t e foregoing is true and correct to the best of my knowledge. Signature f1 0. Title I1A tJL 7~ Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. Î 1(0 Form 10-422 Rev. 4/95 ... BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - BADAMI June-03 - " 7/14/2003 ,4 Page 1 Unplanned Events less than or equal to 1 hour TOTAL 606 Not required for unplanned events which are less than or equal to 1 hour Not required for unplanned events which are less than or equal to 1 hour ~Unplanned Events greater than 1 hour . DATê . TIME VOLUMê 6/17/2003 1036-1148 52 DESCRIPTION OF INCIDENT & CAUSE An unknown PSV was leaking into flare causing a smoky flare. TOTAL 52 ACTION TAKEN TO ELIMINATE CAUSE Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME' DESCRIPTION OF INCIDENT & CAUSE TOTAL o ACTION TAKEN TO ELIMINATE CAUSE ~Planned Events Exceeding 1 Hour OR Exceedin~ 5000 Mcf DATE' TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE TOTAL o Volume flared less than 1 hour 606 Volume flared greater than 52 1 hour Pilot Purge 390 Assist Gas º TOTAL FLARED VOLUME 1,048 ACTION TAKEN .TO ELIMINATE CAUSE ... Assist gas being used to keep flare from being smoky. Source is trying to be identified. ...."''''' ~;"~ ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Field(s) Badami Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 556,108 3. Flared or vented less than 1 hour 839 4. Flared or vented greater than 1 hour 6,562 / (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 403 6. Used for lease operations Assist 0 Fuel 42 580 7. Other TOTAL items 1-7 606,492 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Q~ Title 111c,1l... ~k' Date Ô/IS'/d"J. Form 10-422 Rev. 4/95 MonthlYear of Disposition Jul-03 *Indicate contribution of each pool to total. Pool Name lioae Percent 60100 1. Safety MCF :jefl/ 65'6 2. Lease MCF 3. Conserv. Purposes MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. t{>- ... . 8/12/2003 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT· BADAMI July-03 Page 1 lunPlanned Events less than or equal to 1 hour DATE TIME VOLUME TOTAL 827 DESCRIPTION OF INCIDENT & CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour IUnplanned Events greater than 1 hour DATE TIME VOLUME 7/2/2003 0512-0624 102 7/27/2003 1130-1324 55 TOTAL 157 DESCRIPTION OF INCIDENT & CAUSE Plant SID due to spurious fire alarm in Module 500 VRU went down on High temp Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 7/5/2003 0836-0842 4 IG-A depressure for safe out 7/29/2003 0442-0448 3 Pipe line De-pressure 7/29/2003 0530-0536 2 Pipe line De-pressure 7/29/2003 0612-0618 1 Pipe line De-pressure 7/29/2003 0800-0806 2 Pipe line De-pressure TOTAL 12 ACTION TAKEN TO ELIMINATE CAUSE Re-started plant Re-started VRU ACTION TAKEN TO ELIMINATE CAUSE Make repair on 4th Stage cooler NA NA NA NA Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 7/27/2003 1636-0000 1,007 De-inventory Pipeline 7/28/2003 0000-1418 2,342 Depressuring the pipeline 7/28/2003 1600-0000 379 Venting the Pipline as it is filled from Endicott 7/29/2003 0000-0330 154 Pipe line De-pressure 7/31/2003 0048-0000 2,523 Venting the Pipline as it is filled from Endicott TOTAL 6,405 Volume flared less than 1 hour TOTAL 839 Volume flared greater than 1 hour 6,562 Pilot Purge 403 Assist Gas º TOTAL FLARED VOLUME 7,804 ACTION TAKEN TO ELIMINATE CAUSE NA NA NA NA NA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Field(s) Badami DiSposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold Fuel NGL o o 80,863 Pool Name 60100 ercent 2. Reinjected 3. Flared or vented less than 1 hour 331 5. Pilot and Purge 403 4. Flared or vented Qreater than 1 hour (Supplemental report requlred--See 20 AAC 25.235) 2,490 6. Used for lease operations Assist Fuel o 7646 1. Safety MCF 7. Other 2. Lease '2'.4íO MCF -.:1ß~ TOTAL items 1-7 91,733 3. Conserv. Purposes MCF 8. NGL gas equivalent produced o 31'3/ c¡ . I Date 9. Purchased ç¡as o from Endicott included in above dis ositions 10. Transferred from: 11. Transferred to: I hereby certify that the f regoing is true and correct to the best of my knowledge. Title M,l...II. -r~X Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month folowing the month of disposition. Authority 20 AAC 25.235. Signature Form 10-422 Rev. 4/95 9/3/2003 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - BADAMI August-03 Page 1 Un lanned Events less than or e ual to 1 hour DATE TIME VOLUME TOTAL 316 DESCRIPTION OF INCIDENT 8tCAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour Iunplanned Events greater than 1 hour DATE TIME VOLUME 8/1/2003 0000-0230 8/3/2003 0724-1212 8/3/2003 1354-0000 8/4/2003 0000-2000 8/6/2003 0724-2200 TOTAL 119 184 339 1,280 568 2,490 DESCRIPTION OF INCIDENT & CAUSE VRU Upset VRU Upset VRU Upset VRU Upset VRU upset ACTION TAKEN TO ELIMINATE CAUSE Started VRU De-inventory Facility for shut down De-inventory Facility for shut down Re-started VRU Shutdown the production facility Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 8/8/2003 0324-0336 5 Depressurizing process flowlines 8/8/2003 1336-1354 8 Depressurizing process flowlines 8/8/2003 1418-1424 2 Depressurizing process flowlines TOTAL 15 ACTION TAKEN TO ELIMINATE CAUSE None None None ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE TOTAL o Volume flared less than 1 hour TOTAL 331 Volume flared greater than 1 hour 2,490 I Pilot Purge 403 Assist Gas º TOTAL FLARED VOLUME 3,224 ACTION TAKEN TO ELIMINATE CAUSE ,. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Field(s) Badami Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 0 3. Flared or vented less than 1 hour 7 4. Flared or vented greater than 1 hour 0 (Supplemental report required--See 20 AAC 25.235) 5. Pilot and Purge 390 6. Used for lease operations Assist 0 Fuel 842 7. Other TOTAL items 1-7 1,239 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: NOTE: THERE WAS NO GAS PRODUCED BY BADAMI THIS MONTH. THE GAS USED WAS PREVIOUSLY PRODUCED BY BADAMI AND STORED IN THE UTILITY PIPELINE. I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature átuv .~~ Title 'V()\..Å"<.t. Date t{) 03 Form 1 0-422 Rev. 4/95 MonthlYear of Disposition Sep-03 *Indicate contribution of each pool to total. Pool Name liode Percent 60100 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Operator BP Exploration (Alaska) Inc. Field(s) Badami Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 0 3. Flared or vented less than 1 hour 2 4. Flared or vented greater than 1 hour 0 (Supplemental report required-oSee 20 AAC 25.235) 5. Pilot and Purge 403 6. Used for lease operations Assist 0 Fuel 107 7. Other TOTAL items 1-7 512 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: Title 1Vt&tL-TAX Date Z/-z '{Ioy Form 1 0-422 Rev. 4/95 MonthlYear of Disposition Oct-03 REV 1 *Indicate contribution of each pool to total. Pool Name ,-,oae Percent 60100 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Alaska) Inc. Field(s) Badami Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 0 3. Flared or vented less than 1 hour 0 4. Flared or vented Qreater than 1 hour 0 (Supplemental report required-oSee 20 AAC 25.235) 5. Pilot and Purge 390 ** 6. Used for lease operations Assist 0 Fuel 69 7. Other TOTAL items 1-7 459 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature 0 Q a_),../'..~ Title Mgr, State Taxes & Royalty Date z("?l/fù y Form 10-422 Rev. 4/95 MonthlYear of Disposition Nov-03 REV 1 *Indicate contribution of each pool to total. Pool Name voae Percent 60100 1 . Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Badami Disposition Volume MCF* 1. Sold Fuel 0 NGL 0 2. Reinjected 0 3. Flared or vented less than 1 hour 0 4. Flared or vented greater than 1 hour 0 (Supplemental report required-oSee 20 AAC 25.235) 5. Pilot and Purge 403 ** 6. Used for lease operations Assist 0 Fuel 64 7. Other TOTAL items 1-7 467 8. NGL gas equivalent produced 0 9. Purchased gas o from Endicott included in above disDositions 10. Transferred from: 11. Transferred to: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signaw'e (2 Q. Au -r1 t ~ Title Mg'. Slate T a<os & Royally Date zj ¡vb y Form 10-422 Rev. 4/95 MonthlYear of Disposition Dec-03 REV 2 *Indicate contribution of each pool to total. Pool Name voae Percent 60100 1. Safety MCF 2. Lease MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235.