Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU FS 2 / BPP Exploration STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2003 FACILITY: PBU FS 2 OPERATOR: BP EXPLORATION (ALASKA) INC FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 01/2003 Facility Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 81 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,994 6. Used for lease operations Fuel 829,077 Assist 9 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 848,161 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 382,907 11. Transferred to: CCP 21,416,168 Remarks: I hereby ceotat ~e fOregOi~ is true and correct to the best of my knowledge. Signature: .0,. J. ;.11...... .I. Title: SUPERVISOR *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Form 10-422 (Revised 4/95) BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT January 2003 Page 1 tunplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1/31/2003 1059-1129 81 Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL 81 Unplanned Events reater than 1 hour See attachments See attachments TOTAL o Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Iplanned Events Exceedin~ 1 Hour OR Exceeding 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 81 o o o 19,084 2/7/2003 9:29 AM Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 10perator IField(S) I BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU IMonthNear of Disposition I 02/2003 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 91 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 17,199 6. Used for lease operations Fuel 750,271 Assist 1 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 767,562 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 337,348 11. Transferred to: CCP 20,901,762 Remarks: I hereby ceQ~Qt Re foregoi1 is true and correct to the best of my knowledge. Signature: ,.1. 1, IV1'\. 1. Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT February 2003 Page 1 IUnplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 2/9/2003 0726-0815 32 Not required for unplanned events which 2/20/2003 1630-1647 59 are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour , TOTAL 91 lunplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o IPlanned Events Less Than or Equal 1 Hour AND Not Exceedin9 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ~ TOTAL o rPlanned Events Exceedin~ 1 Hour OR Exceedin~ 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist 91 o o o TOTAL FLARED VOLUME 17,291 3/10/2003 4:31 PM Facility FLOW STATION 2 Disposition 1. Sold 2. Reinjected 3. Flared or vented less than 1 hour. ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 03/2003 Volume MCF* *Indicate contribution of each pool to total. o Pool Name Code Percent o PRUDHOE 640150 100.00% 351 4. Flared or vented greater than 1 hour (Su plemental report re uired - See 20 AAC 25.235) 5. Pilot and Purge 6. Used for lease operations 7. Other TOTAL items 1 -7 8. NGL gas equivalent produced 9. Purchased gas 10. Transferred from: CGF 11. Transferred to: CCP Remarks: Fuel Assist 516 18,876 809,044 14 Lift Gas, Off Field o 828,801 1. Safety 51& MCF J]P- o 2. Lease Use MCF t o 3. Conserv. Purposes MCF 356,345 ~ ~d- A- Commissioner .j1,!o ~ Date 23,180,714 Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 MC 25.235. Signature: Form 10-422 (Revised 4/95) is true and correct to the best of my knowledge. Title: SUPERVISOR BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT March 2003 Page 1 ~Unplanned Events less than or e9ual to 1 hour PATE TIME VOLUME ·OESCRIPTIONOF INCIÐEN¡ &CAUSE¡ 3/3/2003 0353-0409 160 Not required for unplanned events which 3/14/2003 1151-1210 66 are less than or equal to 1 hour 3/17/2003 0852-0916 83 3/17/2003 1517-1529 42 TOTAL 351 ~Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 3/5/2003 1945-2110 516 See attachments , . ACTION TAKEN TOELlMINATE,CAUSE ...... Not required for unplanned events which are less than or equal to 1 hour TOTAL 516 ~Planned Events Less Than or E9ual1 Hour AND Not Exeeedin~ 5000 Met DATE TIME· VOLUME·· DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o Iplanned Events Exceedin~ 1 Hour OR ExeeedinQ 5000 Mct DATE TIME VOLUME ... D.EScRIPT'ON.OFINCID.ENT&CAUSE.·· See attachments TOTAL o t Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 516 o o 19,757 ACTIONTAK.ENTO ELIMINATE CAUSE See attachments ACTION TAKEN TO EUMINATE CAUSE See attachments ACtiON TAI(E'" TO ELIMINATE CAUEiE . See attachments 4/8/2003 11:16AM REPORT NO: 03-0116 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 05 Mar 2003 SYSTEM 1. FlarelRelief Valve TIME OF FLARING Start Stop Duration 19:45 21:10 1 Hrs 25Mins Black Intermittent Smoke Planned o 0 o VOLUME 516 MSCF 516 MSCF TOTAL VOLUME First Determination of Cause: 1. 16-1801 TIC shut down due to seal oil pump instrumentation problem. Note: Stand-by 16-1802 TIC is out of service because of a gas leak on the fuel gas manifold. Action Taken to Stop Flaring: 1. Instrumentation problem resolved, restarted 16-1801 TIC. Monday, March 31, 2003 Page 1 of 1 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 667 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,085 6. Used for lease operations Fuel 753,057 Assist 792 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 772,601 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 322,805 11. Transferred to: CCP 23,011,020 Remarks: I hereby Ce()t¡hat th{ foregoing is true and correct to the best of my knowledge. Signature: (/ I (\ A ¡ /\All I Title: SUPERVISOR . Facility FLOW STATION 2 Form 10-422 (Revised 4/95) ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 04/2003 *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - F5-2 GAS FLARING INCIDENT REPORT April 2003 Junplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 4/12/2003 1552-1607 150 Not required for unplanned events which 4/17/2003 1755-1804 31 are less than or equal to 1 hour 4/18/2003 0135-0157 76 4/26/2003 0735-0821 410 Page 1 TOTAL 667 Junplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceedin~ 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist 667 o o o TOTAL FLARED VOLUME 19,544 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 5n /2003 4:09 PM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU OS/2003 FLOW STATION 2 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 817 4. Flared or vented greater than 1 hour 6,865 ./ (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,515 6. Used for lease operations Fuel 623,983 Assist 1,784 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 651,964 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 285,719 11. Transferred to: CCP 16,314,234 Remarks: I hereby certifr.:¿at thrOregOi] is true and correct to the best of my knowledge. Signature: a,..A A...... 11 Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety -bßb5 MCF ~ , 2. Lease Use MCF 3. Conserv. Purposes MCF 7/31 )_5 Date Commissioner Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT May 2003 Page 1 5/13/2003 5/17/2003 5/18/2003 5/25/2003 5/26/2003 1948-2031 0245-0320 2000-2058 1930-2007 1402-1428 119 Not required for unplanned events which 350 are less than or equal to 1 hour 115 139 94 Not required for unplanned events which are less than or equal to 1 hour TOTAL 817 Unplanned Events greater than 1 hour 5/13/2003 5/20/2003 0618-0931 1602-1731 10 Intermittent (see attachments) 578 See attachments TOTAL 588 Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist 5/9/2003 5/9/2003 See attachments See attachments TOTAL o 0330-0440 0455-0645 See attachments ~c~k M¡'s':.t~ 0ls.¿ 1/1 ~lò3 TOTAL 6,277 588 o 6,277 TOTAL FLARED VOLUME 27,981 6/9/2003 11:33 AM bp REPORT NO: 03-0285 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 09 May 2003 TIME OF FLARING SYSTEM Start Stop Duration 1. Controlled Blowdow 03:30 04:40 1 Hrs 10 Mins 2. Controlled Blowdow 04:55 06:45 1 Hrs 50 Mins Black Intermittent Smoke Planned VOLUME 0 0 ~ 4,293 MSCF 0 0 ~ 1,984 MSCF TOTAL VOLUME 6,277 MSCF First Determination of Cause: 1. CONTROLLED DEPRESSURING OF ALL COMMON LINES FOR A SHUT DOWN. 2. CONTROLLED BLOW DOWN OF GAS VESSELS AND TRAINS FOR A SHUT DOWN Action Taken to Stop Flaring: 1. COMPLETED DEPRESSURING 2. COMPLETED DEPRESSURING Friday, May 23, 2003 Page 1 of 1 REPORT NO: 03-0302 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 13 May 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 06:18 09:31 3Hrs 13 Mins ~ 0 0 10 MSCF 19:48 20:31 o Hrs 43 Mins 0 0 0 119 MSCF TOTAL VOLUME 129 MSCF First Determination of Cause: 1. GAS LEAK BY AROUND TREATER BACK PRESSURE CONTROLLERS DURING PLANT REPRESSURIZA TION. 2. FLARING OFF BOTH SIC'S DURING AL WARM-UP Action Taken to Stop Flaring: 1. BLOCKED GAS OUTLETS ON TREATERS. 2. COMPLETED WARM-UP Friday, May 23, 2003 Page 1 of 1 FACILITY: FS2 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0329 BPXA FLARE REPORT PRUDHOE BAY DATE: 20 May 2003 TIME OF FLARING Start Stop Duration 16:02 17:31 1 Hrs 29Mins First Determination of Cause: 1. 1801 turbine shutdown on mechanical problem. Flare volume based upon 89 min x (9243mscfD) Black Intermittent Smoke o 0 Planned TOTAL VOLUME o Action Taken to Stop Flaring: 1. after attempting to start 1801 decision was made to start 1802. Friday, May 23, 2003 VOLUME 578 MSCF 578 MSCF Page 1 of 1 Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 06/2003 FLOW STATION 2 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 616 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,234 6. Used for lease operations Fuel 801,182 Assist 4 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 820,036 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 367,848 11. Transferred to: CCP 20,711,897 Remarks: I hereby certtZt~troregOing Ö true and correct to the best of my knowledge. Signature: - . .A 11 ^A~ 1.t Title: SUPERVISOR - I Form 10 422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· FS-2 GAS FLARING INCIDENT REPORT June 2003 Page 1 6/2/2003 6/4/2003 6/9/2003 6/22/2003 0912-0942 1929-1940 0855-0909 0906-0945 250 Not required for unplanned events which 76 are less than or equal to 1 hour 140 150 Not required for unplanned events which are less than or equal to 1 hour TOTAL 616 Un lanned Events greater than 1 hour Intermittent (see attachments) See attachments TOTAL o Planned Events Less Than or Equal 1 Hour AND Not Exceedin 5000 Mcf See attachments See attachments TOTAL o See attachments See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o 18.854 7/9/2003 2:14 PM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) I BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU Month/Year of Disposition I 07/2003 FLOW STATION 2 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,662 6. Used for lease operations Fuel 824,989 Assist 8 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 843,659 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 375,164 11. Transferred to: CCP 22,354,130 Remarks: I hereby cert()~hat thecgOing ijUe and correct to the best of my knowledge. Signature: . (1. A ~ I t Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT July 2003 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE Not required for unplanned events which are less than or equal to 1 hour Page 1 TOTAL o ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ~Unplanned Events greater than 1 hour DATE TIME VOLUME TOTAL DESCRIPTION OF INCIDENT & CAUSE Intermittent (see attachments) o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mef DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o o o 18,670 ACTION TAKEN TO ELIMINATE CAUSE See attachments 8/11/2003 1:15 PM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 08/2003 FLOW STATION 2 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 192 4. Flared or vented greater than 1 hour 712 ..,,/ (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,673 6. Used for lease operations Fuel 786,754 Assist 10 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 806,341 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 350,175 11. Transferred to: CCP 19,334,072 Remarks: I hereby cert~hat the ~Oing i:te and correct to the best of my knowledge. Signature: ~ (1. AA't 'h Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety 7 ( 2--- MCF -.::J8r--- 2. Lease Use MCF 3. Conserv. Purposes MCF ~~~ Commissioner I '/ ~I D.:J Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Page 1 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - F5-2 GAS FLARING INCIDENT REPORT August 2003 ¡unPlanned Events less than or equal to 1 hour . DATE TIME VOLUME DESCRIPTION OF INCIDENT It CAUSE 8/8/2003 1640-1717 192 Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL 192 8/16/2003 1053-1418 712 See attachments See attachments TOTAL 712 Jplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT It CAUSE See attachments . ACTION TAKEN TO ELIMINATE CAUSE See attachments , TOTAL o Planned Events Exceedin 1 Hour OR Exceeding 5000 Mcf See attachments See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist 192 712 o o TOTAL FLARED VOLUME 19,587 9/9/2003 9:04 AM FACILITY: FS2 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0487 BPXA FLARE REPORT PRUDHOE BAY DATE: 16 Aug 2003 TIME OF FLARING Start Stop Duration 10:53 14:18 3Hrs 25Mins Black Intermittent Smoke D D TOTAL VOLUME D First Determination of Cause: 1. TC-1802 SID DUE TO AN OVERHEATED ELECTRICAL BREAKER Action Taken to Stop Flaring: 1. THE'13HEAKER WASREPtA'CEDcANDTHE"MACHINE RESTARTED Thursday, August 21, 2003 '. Planned VOtUME 712 MSCF 712 MSCF Page 1 of 1 Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 09/2003 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,094 6. Used for lease operations Fuel 760,595 Assist 0 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 778,689 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 337,611 11. Transferred to: CCP 19,310,229 Remarks: I hereby ceÕ. that t~ fOregO)s true and correct to the best of my knowledge. Signature: .0. A A /VI" OA Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT September 2003 Page 1 IUnplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT It CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL o tunplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT It CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT It CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT It CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist o o o o TOTAL FLARED VOLUME 18,094 10/7/2003 10:28 AM FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 10/2003 Facility Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold o Pool Name Code Percent 2. Reinjected o PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 1,180 4. Flared or vented greater than 1 hour (Supplemental report required - See 20 AAC 25.235) 18,961 5. Pilot and Purge 18,614 6. Used for lease operations Fuel Assist 790,730 20 7. Other Lift Gas, Off Field o TOTAL items 1 - 7 829,505 1 . Safety l<at'1"( MCF ~ 8. NGL gas equivalent produced o 2. Lease Use MCF 9. Purchased gas o 3. Conserv. Purposes MCF 10. Transferred from: CGF 350,434 1.1þi¿ Date 11. Transferred to: CCP 20,631,465 foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 MC 25.235. Remarks: Signature: Form 10-422 (Revised 4/95) Title: SUPERVISOR BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT October 2003 Page 1 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/11/2003 0200-0300 328 Not required for unplanned events which 10/12/2003 1500-1515 76 are less than or equalto 1 hour 10/12/2003 2300-2340 156 10/25/2003 1311-1317 60 10/25/2003 2047-2057 100 10/27/2003 0904-0935 310 10/29/2003 0018-0033 150 TOTAL 1,180 lunplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 10/11/2003 0400-0700 416 See attachments 10/12/2003 1000-1200 416 10/12/2003 1500-1830 729 10/12/2003 1800-1930 17,400 TOTAL 18,961 Iplanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 18,961 o o 38,775 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 11/7/2003 1:54PM REPORT NO: 03-0576 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 11 Oct 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Start Stop Duration 02:00 03:00 1 Hrs Black Intermittent Smoke Planned 04:00 07:00 3 Hrs OMins o o o o o o VOLUME 328 MSCF 416 MSCFJ OMins TOTAL VOLUMEc744MSGF First Determination of Cause: 1. Depressured "A" Gas Conditioning Train for TEG replacement and maintenance. 2. Spin cool 16-1803 for water wash and maintenance Action Taken to Stop Flaring: 1. Depressure complete. 2. Completed cooldown. Volume based on 5mmscf/d or 3472 per/min x 120 mins. Tuesday, October 21,2003 Page 1 of 1 REPORT NO: 03-0577 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 12 Oct 2003 TIME OF FLARING SYSTEM Start Stop Duration Intermittent 1. Flare/Relief Valve 10:00 12:00 2Hrs OMins 0 2. Flare/Relief Valve 15:00 18:30 3Hrs 30Mins 0 3. Flare/Relief Valve 15:00 15:15 OHrs 15Mins 0 4. Flare/Relief Valve 18:00 19:30 1 Hrs 30Mins 0 5. Flare/Relief Valve 23:00 23:40 OHrs 40Mins 0 Black Smoke Planned VOLUME 0 0 416 MSCF / 0 0 729 MSCF ./ 0 0 76,MSCF 0 0 17,400 MSCF I 0 0 156 MSCF TOTAL VOLUME 18,777 MSCF First Determination of Cause: 1. Water washed 16-1803, semi-annual pm/maint. 2. spin cool 1804 for maint. Based upon 3472scfd x 210 mins. 3. Shut down 16-1804 for water wash/inspection 4. 1803 Ips shutdown on high level on suction scrubber. HAD NO LPS COMPRESSION.aueto1804 down for maint. Rate based on 280mmscfd -~"---,".,-., ' 5. waterwash 1804 based upon 3472scfd x 45 minutes Action Taken to Stop Flaring: 1. shut down water wash. Volume based on 5mmscf/d or 3472scf x 120 minutes. 2. stopped spin cooling 3. 16-1804 LPS train depressured. 4. lowered level and solved instrumentation problems 5. stopped waterwash Tuesday, October 21, 2003 Page 1 of 1 " Facility FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 11/2003 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 3,443 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 18,273 6. Used for lease operations Fuel 783,706 Assist 2 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 805,424 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 340,162 11. Transferred to: CCP 22,312,681 Remarks: I hereby ce(2,(j.t le fOregOin~ is true and correct to the best of my knowledge. Signature: ' . L_. ~ Á Title: SUPERVISOR ( Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. o , BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-2 GAS FLARING INCIDENT REPORT November 2D03 'Unplanned Events less than or equal to 1 hour DATE TIME .vOLUME DESCRII1T Ott;OFdNCIDENT'8<iCAIJSE 11/4/2003 0300-0344 380 Not required for unplanned events which 11/5/2003 2140-2152 120 are less than or equal to 1 hour 11/6/2003 0013-0033 200 11/8/2003 1335-1353 180 11/9/2003 0236-0245 90 11/9/2003 0303-0318 150 11/9/2003 0326-0351 250 11/9/2003 0358-0421 230 11/9/2003 2158-2213 150 11/9/2003 2328-2359 310 11/10/2003 0003-0017 140 11/10/2003 0409-0413 40 11/10/2003 1341-1356 150 11/10/2003 2144-2201 170 11/11/2003 1313-1329 160 11/15/2003 1413-1423 63 11/20/2003 0403-0420 170 11/20/2003 0656-0712 160 11/20/2003 1110-1114 40 11/23/2003 1417-1428 110 11/27/2003 0355-0405 100 11/29/2003 0240-0248 80 TOTAL 3,443 Page 1 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour 'Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o ACTION TAKEN TO ELIMINATE CAUSE See attachments 'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mct DATE TIME VOLUME· DESCRII1TION OF INCIDENT 8< CAUSE See attachments TOTAL o ACTION TAKEN TO ELIMINATE CAUSE See attachments IPlanned Events Exceedinl/ 1 Hour OR Exceedin!i 5000 Mct DATE TIME VOLUME DESCRII1T10N OF INCIDENT 8< CAUSE See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist o o o TOTAL FLARED VOLUME 21,718 12/5/2003 10:22 AM FLOW STATION 2 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) MonthNear of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 12/2003 Facility Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold o Pool Name Code Percent 2. Reinjected o PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 20,292 4. Flared or vented greater than 1 hour (Supplemental re ort required - See 20 AAC 25.235) 16,875 5. Pilot and Purge 19,102 6. Used for lease operations Fuel Assist 819,887 11 7. Other Lift Gas, Off Field o TOTAL items 1 - 7 8. NGL gas equivalent produced o 1. Safety 11£75' MCF ~ I 2. Lease Use MCF 3. Conserv. Purposes MCF 876,167 9. Purchased gas o 10. Transferred from: CGF 352,097 11. Transferred to: CCP 22,171,062 Remarks: Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - F5-2 GAS FLARING INCIDENT REPORT December 2003 12/6/2003 12/13/2003 12/15/2003 12/16/2003 12/18/2003 12/20/2003 12/21/2003 12/24/2003 0851-0856 1947-2021 1614-1624 0935-1 030 0930-0940 1603-1614 1144-1146 1302-1321 TOTAL 50 Not required for unplanned events which 7,555 are less than or equal to 1 hour 100 12,222 50 110 20 185 20,292 Unplanned Events greater than 1 hour 12/19/2003 0910-1040 TOTAL 16,875 See attachments 16,875 Planned Events Less Than or Equal 1 Hour AND Not Exceedin 5000 Mcf See attachments TOTAL o Page 1 Not required for unplanned events which are less than or equal to 1 hour See attachments See attachments Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME See attachments o 16,875 o o 56,280 See attachments 1/6/2004 3:44 PM REPORT NO: 03-0670 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS2 DATE: 19 Dec 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 09:10 10:40 1 Hrs 30Mins 0 0 0 16,875'MSCF TOTAL VOLUME 16,875 MSCF First Determination of Cause: 1. Trubine 1804 was shutdown, by 24 volt ground fault, while doing an FCC of new de-mister. Action Taken to Stop Flaring: 1. reported'ffl6iØent"oIeared shutdown alarms","Made Wéü shut in list, 50 min. into incident began restart of machine. 1804 came up on one start load machine'and flare went out. Monday, December22,2003 Page 1 of 1