Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU FS 3 / BP Exploration STATE OF AIASKA AOGCC GAS DISPOSITION FILES YEAR: 2003 FACILITY: PBU FS 3 OPERATOR: BP EXPLORATION (AIASKA) IN C FLOW STATION 3 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 01/2003 Facility Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold o Pool Name Code Percent 2. Reinjected o PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 24 4. Flared or vented greater than 1 hour (Su plemental report required - See 20 AAC 25.235) 2,257 5. Pilot and Purge 20,315 6. Used for lease operations Fuel Assist 1,018,472 1 ,402 7. Other Lift Gas, Off Field o TOTAL items 1 - 7 1,042,470 1 . Safety "2( 257 MCF ::::SSp- 8. NGL gas equivalent produced o 2. Lease Use MCF 9. Purchased gas o 3. Conserv. Purposes MCF 10. Transferred from: CGF 1,038,787 ((o.-k; L~~ ~ Commissioner 7(tlo] , Date 11. Transferred to: CCP 28,888,682 Remarks: Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Signature: Form 10-422 (Revised 4/95) Title: SUPERVISOR BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS·3 GAS FLARING INCIDENT REPORT January 2003 Page 1 'unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1/16/2003 1935-1940 3 Not required for unplanned events which are less than or equal to 1 hour TOTAL 3 JUnplanned Events ~reater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1/4/2003 1400-1508 660 See attachments 1/14/2003 1935-2100 546 TOTAL 1,206 ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1/16/2003 0840-0845 3 See attachments 1/16/2003 1410-1415 3 1/16/2003 2210-2215 3 1/17/2003 1950-1955 3 1/26/2003 1730-1735 3 1/27/2003 1555-1600 3 1/27/2003 1650-1655 3 TOTAL 21 'planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1/11/2003 0145-0300 83 See attachments 1/11/2003 0300-0415 83 1/11/2003 0345-0500 885 TOTAL 1,051 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist 1,206 21 1,051 TOTAL FLARED VOLUME 23,998 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 217/2003 9:28 AM REPORT NO: 03-0006 BPXA FLARE REPORT PRUDHOE SAY FACILITY: FS3 DATE: 04 Jan 2003 SYSTEM 1. Other TIME OF FLARING Start Stop Duration 14:00 15:08 1 Hrs 8 Mins Black Intermittent Smoke Planned ~ 0 o VOLUME 660 MSCF 660 MSCF TOTAL VOLUME First Determination of Cause: 1. Power supply failure on Flare Valve Staging Panel. Power supply fuse blew causing staging valves to open which opened the Assist Gas valves to the STV Flare valves. Volume found on Meter 373. Action Taken to Stop Flaring: 1. Replaced blown fuse on power supply and reset valve panel. Monday, January 20, 2003 Page 1 of 1 REPORT NO: 03-0021 SPXA FLARE REPORT PRUDHOE SAY FACILITY: FS3 DATE: 11 Jan 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Controlled 810wdow 01:45 03:00 1 Hrs 15 Mins 0 0 ~ 83 MSCF 2. Controlled 810wdow 03:00 04:15 1 Hrs 15 Mins 0 0 ~ 83 MSCF 3. Controlled 810wdow 03:45 05:00 1 Hrs 15 Mins 0 0 ~ 885 MSCF TOTAL VOLUME 1,051 MSCF First Determination of Cause: 1. Normal depressure of 60 from LPS pressure to flare for maintenance at OS6 2. Normal depressure of 68 from LPS pressure to flare for maintenance at OS6 3. Normal depressure of 6C/138 from LPS pressure to flare for maintenace at OS6 Action Taken to Stop Flaring: 1. Completed de-pressuing the 60 common line 2. Completed depressure of 68 common line 3. Completed depressure of 6C/138 common line Monday, January 20, 2003 Page 1 of 1 REPORT NO: 03-0025 SPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 14 Jan 2003 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 19:35 21 :00 1 Hrs 25 Mins Black Intermittent Smoke Planned o 0 o VOLUME 546 MSCF 546 MSCF TOTAL VOLUME First Determination of Cause: 1. 1801 T/C BEGAN SURGING. COULD NOT DETERMINE THE CAUSE SO NORMAL STOPPED IT. SOME SMOKE IN THE MODULE, SO A WORK REQUEST HAS BEEN TURNED IN FOR REPAIRS. Action Taken to Stop Flaring: 1. STARTED 1802 T/C AFTER TWO STARTS. Monday, January 20, 2003 Page 1 of 1 REPORT NO: 03-0028 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 16 Jan 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 08:40 08:45 OHrs 5Mins 0 0 ~ 3 MSCF 2. Flare/Relief Valve 14:10 14:15 OHrs 5Míns 0 0 ~ 3 MSCF 3. Flare/Relief Valve 19:35 19:40 OHrs 5Mins 0 0 0 3 MSCF 4. Flare/Relief Valve 22:10 22:15 OHrs 5Mins 0 0 ~ 3 MSCF TOTAL VOLUME 12 MSCF First Determination of Cause: 1. 1802 T /C shutdown while attempting to manually slowdown to idle. 1801 T/C was previously brought online and loaded. 2. 1801 T/C shutdown for maintenance work. 3. 1801 T/C shutdown while attempting to idle on high vibration std. 4. 1801 T/C shutdown for maintenance work. Action Taken to Stop Flaring: 1. 1802 normal shutdown. 2. Normal compressor/piping blowdown volume. 3. Normal compressor/piping blowdown volume. 4. Normal compressor/piping blowdown volume. Monday, January 20, 2003 Page 1 of 1 FACILITY: FS3 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0031 BPXA FLARE REPORT PRUDHOE BAY DATE: 17 Jan 2003 TIME OF FLARING Start Stop Duration 19:50 19:55 0 Hrs 5 Mins First Determination of Cause: 1. SID 1802 tic and returned to standby. Action Taken to Stop Flaring: 1. Normal compressor piping blowdown volume. Monday, January 20, 2003 Black Intermittent Smoke o 0 Planned TOTAL VOLUME ~ VOLUME 3 MSCF 3 MSCF Page 1 of 1 FACILITY: FS3 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0062 BPXA FLARE REPORT PRUDHOE BAY DATE: 26 Jan 2003 TIME OF FLARING Start Stop Duration 17:30 17:35 OHrs 5Mins First Determination of Cause: 1. SID 1802 Vc and returned to standby after test run. Action Taken to Stop Flaring: 1. Normal compressor and piping blowdown volume. Tuesday, January 28, 2003 Black Intermittent Smoke o 0 Planned TOTAL VOLUME ~ VOLUME 3 MSCF 3 MSCF Page 1 of 1 REPORT NO: 03-0064 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 27 Jan 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 15:55 16:00 OHrs 5Mins 0 0 ~ 3 MSCF 16:50 16:55 OHrs 5Mins 0 0 ~ 3 MSCF TOTAL VOLUME 6 MSCF First Determination of Cause: 1. 1802 T /C Normal shutdown from idle. Troubleshooting NPT speed fluctuations. 2. 1802 T /C Normal shutdown from idle. More troubleshooting speed fluctuations. Action Taken to Stop Flaring: 1. Normal shutdown. 2. Normal shutdown. Tuesday, January 28, 2003 Page 1 of 1 FLOW STATION 3 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION IOperator I Field(s) I BP EXPLORATION, ALASKA JEASTERN OPERATING AREA-PBU I MonthlY ear of Disposition I 02/2003 Facility Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 168 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 22,521 6. Used for lease operations Fuel 930,089 Assist 622 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 953,400 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 952,610 11. Transferred to: CCP 28,989,916 Remarks: I hereby ceQ. that t~ foregOingptrue and correct to the best of my knowledge. Signature: w' a . Å À ....~ i J Title: SUPERVISOR *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Form 10-422 (Revised 4/95) BP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT - FS-3 GAS FLARING INCIDENT REPORT February 2003 Page 1 lunplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 2/17/2003 1355-1420 153 Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour i TOTAL 153 ,unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 2/14/2003 1630-1635 3 See attachments 2/14/2003 2220-2225 3 2/16/2003 1600-1605 3 2/16/2003 1745-1750 3 2/19/2003 1720-1725 3 ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL 15 ~ ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments TOTAL 0 Unplanned Events < 1 Hour Unplanned Events> 1 Hour 0 Planned Events < 1 hour and not 15 exceeding 5,000 MCF Planned Events> 1 hour or 0 exceeding 5,000 MCF Pilot Purge Assist 3/10/2003 TOTAL FLARED VOLUME 23,311 4:31 PM REPORT NO: 03-0089 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 14 Feb 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 16:30 16:35 OHrs 5Mins 0 0 ~ 3 MSCF 22:20 22:25 OHrs 5Mins 0 0 ~ 3 MSCF TOTAL VOLUME 6 MSCF First Determination of Cause: 1. 1802 T/C Shutdown from idle during maintenance trouble-shooting. 2. 1802 T /C Shutdown after maintenance trouble-shooting. Action Taken to Stop Flaring: 1. Normal shutdown. 2. Normal shutdown. Unit returned to Standby Mode. Monday, February 24, 2003 Page 1 of 1 REPORT NO: 03-0091 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 16 Feb 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve .TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 16:00 16:05 OHrs 5Mins 0 0 ~ 3 MSCF 17:45 17:50 OHrs 5Mins 0 0 ~ 3 MSCF TOTAL VOLUME 6 MSCF First Determination of Cause: 1. shut down 1802 tJc for more maintenance 2. shut down 1802 tJc for more maintenance Action Taken to Stop Flaring: 1. normal compressor and piping blowdown volume 2. normal compressor and piping blowdown volume Monday, February 24, 2003 Page 1 of 1 FACILITY: FS3 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0094 BPXA FLARE REPORT PRUDHOE BAY DATE: 19 Feb 2003 TIME OF FLARING Start Stop Duration 17:20 17:25 OHrs 5Mins First Determination of Cause: 1. Shutdown 1801 Vc, returned to standby. Action Taken to Stop Flaring: 1. Normal compressor and piping blowdown volume. Monday, February 24, 2003 Black Intermittent Smoke o 0 Planned TOTAL VOLUME ~ VOLUME 3 MSCF 3 MSCF Page 1 of 1 FLOW STATION 3 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s Month/Year of isposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 03/2003 Facility Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 2,170 4. Flared or vented greater than 1 hour 0 (Supplemental report reauired - See 20 AAC 25.235) 5. Pilot and Purge 37,620 6. Used for lease operations Fuel 1,015,444 Assist 1,442 7. Other Lift Gas, Off Field 0 TOTAL items 1 -7 1,056,676 8. NGL gas equivalent produced 0 9. Purchased gas 0 , 10. Transferred from: CGF 1,053,064 11. Transferred to: CCP 31,442,775 Remarks: I hereby cet({)t ~e fore~is true and correct to the best of my knowledge. Signature: . . .A . J, Title: SUPERVISOR Form 10-422 Revised 4795 *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· FS-3 GAS FLARING INCIDENT REPORT March 2003 IUnplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 3/11/2003 0746·0810 633 Not required for unplanned events which 3/11/2003 1047-1100 341 are less than or equal to 1 hour 3/11/2003 1121-1206 1,181 3/23/2003 1005-1008 3 3/23/2003 1115-1118 3 3/23/2003 1430-1433 3 3/23/2003 1520-1523 3 3/24/2003 1630-1633 3 Page 1 TOTAL 2,170 AC.TlON TAI<ENTOELIMINATECAUSE Not required for unplanned events which are less than or equal to 1 hour ~Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION.OF INCIDENT& CAUSE See attachments TOTAL o ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL 0 , TOTAL 2,170 0 0 0 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 41,232 ACTION TAKEN TO ELIMINATE CAUSE See attachments 4/8/2003 11:20AM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 04/2003 FLOW STATION 3 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 633 4. Flared or vented greater than 1 hour 422 ,/ (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 40,756 6. Used for lease operations Fuel 917,093 Assist 3,180 7. Other Uft Gas, Off Field 0 TOTAL items 1 - 7 962,084 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 957,849 11. Transferred to: CCP 25,090,899 Remarks: I hereby ceL¿ that It fOregO~~ is true and correct to the best of my knowledge. Signature: .0 J.. A A^ Å. Title: SUPERVISOR Form 10-422 Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety ~2Z- MCF Gßf2- 2. Lease Use MCF 3. Conserv. Purposes MCF fier jß{þ3 Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-3 GAS FLARING INCIDENT REPORT April 2003 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT 8< CAUSE 4/11/2003 1500-1555 281 Not required for unplanned events which 4/14/2003 1500-1543 239 are less than or equal to 1 hour Page 1 TOTAL 520 ~Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exeeedin~ 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 4/2/2003 0807-0810 107 See attachments 4/6/2003 2050-2110 3 4/15/2003 1400-1405 3 TOTAL 113 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Met DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 4/6/2003 0530-0700 422 See attachments TOTAL 422 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o 113 422 44,991 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 5/7/2003 4: 10 PM REPORT NO: 03-0167 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 02 Apr 2003 TIME OF FLARING SYSTEM Start Stop Duration 1. Controlled Blowdow 08:07 08:10 OHrs 3 Mins Black Intermittent Smoke Planned o 0 ~ VOLUME 107 MSCF 107 MSCF TOTAL VOLUME First Determination of Cause: 1. DEPRESSURED "A" HIGH PRESSURE SERARATOR AND GAS SCRUBBER AFTER OIL TRAIN SHUT DOWN FOR REGENERATOR SKID WORK Action Taken to Stop Flaring: 1. VESSEL DEPRESSURED AND ISOLATED. Wednesday, April 30, 2003 Page 1 of 1 REPORT NO: 03-0182 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 06 Apr 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 05:30 07:00 1 Hrs 30 Mins 0 0 ~ 422 MSCF 20:50 21:10 OHrs 20 Mins 0 0 ~ 3 MSCF TOTAL VOLUME 425 MSCF First Determination of Cause: 1. De pressured 15B and 150 for work on 15B corrosion cupon and divert valve changes at DS15. 2. DEPRESSURED PIPING INSIDE OF DRILL SITE MANIFOLD BUILDING FOR MAINTENANCE. Action Taken to Stop Flaring: 1. Completed de pressuring common lines 15B and 150. 2. FINISHED DEPRESSURING AND ISOLATED GAS SOURCE VVednesday, Apñl30, 2003 Page 1 of 1 REPORT NO: 03-0220 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 15 Apr 2003 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 14:00 14:05 0 Hrs 5 Mins Black Intermittent Smoke Planned o 0 ~ VOLUME 3 MSCF 3 MSCF TOTAL VOLUME First Determination of Cause: 1. Shut down and returned tic 1802 to standby after repairs to tic 1801 completed, started and loaded. Action Taken to Stop Flaring: 1. Normal compressor and piping blowdown volume. VVednesday,Apri/30,2003 Page 1 of 1 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 1,891 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 42,148 6. Used for lease operations Fuel 880,470 Assist 24,586 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 949,095 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 922,618 11. Transferred to: CCP 25,923,598 Remarks: I hereby ceo.tat t fOreg~~ is true and correct to the best of my knowledge. Signature: 0 .A . '1. Title: SUPERVISOR Facility FLOW STATION 3 Form 10-422 (Revised 4/95) ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU OS/2003 *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT - FS-3 GAS FLARING INCIDENT REPORT May 2003 Page 1 'unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION'OF'INCIDENT&'CAUSE 5/4/2003 1530-1540 155 Not required for unplanned events which 5/4/2003 1600-1610 155 are less than or equal to 1 hour 5/4/2003 1630-1640 155 5/4/2003 1650-1655 155 5/19/2003 2110-2115 40 TOTAL 660 ~unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o JPlanned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTIONOFINCIDENT&CAUSE 5/2/2003 0120-0130 240 See attachments 5/9/2003 1715-1725 240 5/10/2003 1515-1520 155 5/10/2003 1555-1600 155 5/12/2003 1055-1100 155 5/17/2003 0040-0045 60 5/17/2003 0225-0300 26 5/17/2003 0751-0820 20 5/19/2003 1915-1920 40 5/22/2003 0115-0130 60 5/22/2003 2210-2230 80 TOTAL 1,231 Iplanned Events Exceeding 1 Hour OR Exceedin9 5000 Mct DATE TIME VOLUME DESCRIPTION OFJNCIDeNT & CAUSE See attachments TOTAL o TOTAL 660 o 1,231 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist o TOTAL FLARED VOLUME 68,625 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 6/9/2003 11:35 AM FACILITY: FS3 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0267 BPXA FLARE REPORT PRUDHOE BAY DATE: 02 May 2003 TIME OF FLARING Start Stop Duration 01 :20 01 :30 0 Hrs 10 Mins Black Intermittent Smoke o 0 TOTAL VOLUME ~ First Determination of Cause: 1. Normal stop 1806 AL compressor for a spring water wash. Action Taken to Stop Flaring: 1. Normal depressuring completed. Friday, May 23, 2003 Planned VOLUME 240 MSCF 240 MSCF Page 1 of 1 FACILITY: FS3 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0286 BPXA FLARE REPORT PRUDHOE BAY DATE: 09 May 2003 TIME OF FLARING Start Stop Duration 17:15 17:25 0 Hrs 10Mins Black Intermittent Smoke Planned o 0 ~ TOTAL VOLUME First Determination of Cause: 1. 1806 T /C Normal Shutdown from idle for maintenance/repair of Starting Turbine. Action Taken to Stop Flaring: 1. Normal Shutdown. Friday, May 23, 2003 VOLUME 240 MSCF 240 MSCF Page 1 of 1 REPORT NO: 03-0289 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 10 May 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 15:15 15:20 OHrs 5Mins 0 0 ~ 155 MSCF 15:55 16:00 OHrs 5Mins 0 0 ~ 155 MSCF TOTAL VOLUME 310 MSCF First Determination of Cause: 1. 1806 T/C Aborted Start. During attempted Cranking Test after maintenance on Starting Turbine. (IB Bearing Seal repair) 2. 1806 T/C Aborted Start. During attempted Cranking Test after maintenance on Starting Turbine. (IB Bearing Seal repair) Action Taken to Stop Flaring: 1. Normal Shutdown from aborted start. 2. Normal Shutdown from aborted start. Friday, May 23, 2003 Page 1 of 1 REPORT NO: 03-0296 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 12 May 2003 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 10:55 11 :00 0 Hrs 5 Mins Black Intermittent Smoke Planned o 0 ~ VOLUME 155 MSCF 155 MSCF TOTAL VOLUME First Determination of Cause: 1. 1806 T /C Aborted Start. During Cranking Test after maintenance on Starting Turbine. (18/08 Seal replacements) Action Taken to Stop Flaring: 1. Normal shutdown from aborted start. Friday, May 23, 2003 Page 1 of 1 REPORT NO: 03-0315 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 17 May 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 00:40 00:45 OHrs 5Mins 0 0 ~ 60 MSCF 2. Flare/Relief Valve 02:25 03:00 OHrs 35 Mins 0 0 ~ 26 MSCF 3. Flare/Relief Valve 07:51 08:20 OHrs 29 Mins 0 0 ~ 20 MSCF TOTAL VOLUME 106 MSCF First Determination of Cause: 1. Shut down 1804 tic for waterwash and combustion inspection. 2. Depressured C train IP Separator and Treater for maintenance work. 3. Depressured 1804 suction scrubber and associated piping for maintenance work on compressor. Action Taken to Stop Flaring: 1. Normal shutdown compressor and piping blowdown volume. 2. Depressuring completed. 3. Depressuring completed. Friday, May 23, 2003 Page 1 of 1 REPORT NO: 03-0322 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 19 May 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Slack Start Stop Duration Intermittent Smoke Planned VOLUME 19:15 19:20 OHrs 5Mins 0 0 ~ 40 MSCF 21:10 21:15 OHrs 5Mins 0 0 0 40 MSCF TOTAL VOLUME 80 MSCF First Determination of Cause: 1. SID 1804 turbine after waterwash. 2. Failed start attempt on 1804 tic. Action Taken to Stop Flaring: 1. Compressor case and piping depressured as normal. 2. Compressor case and piping depressured as normal. Friday, May 23, 2003 Page 1 of 1 REPORT NO: 03-0338 BPXA FLARE REPORT PRUDHOE SAY FACILITY: FS3 DATE: 22 May 2003 SYSTEM 1. FlarelRelief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOLUME 01:15 01:30 o Hrs 15Mins 0 0 ~ 60 MSCF 22:10 22:30 o Hrs 20 Mins 0 0 ~ 80 MSCF TOTAL VOLUME 140 MSCF First Determination of Cause: 1. 1803 TIC SHUT DOWN FOR WATER WASH AND INSPECTION 2. 1803 TIC PURGED DURING RESTART Action Taken to Stop Flaring: 1. COMPo TRAIN DEPRESSURED AND SECURED 2. TIC BROUGHT ON LINE Friday, May 23, 2003 Page 1 of 1 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 3 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 40,669 6. Used for lease operations Fuel 'I?/¡j h'l('1 923,445 Assist !. 15,134 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 979,251 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 964,114 11. Transferred to: CCP 26,245,809 Remarks: I hereby cert() (\th( fOregOi~S true and correct to the best of my knowledge. Signature: ...{ . N'lA.. d.t Title: SUPERVISOR Facility FLOW STATION 3 Form 10-422 (Revised 4/95) ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION IOperator IField(S) I BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU I Month/Year of Disposition I 06/2003 *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% ......;..·.·.····>.····.·.·.<..··.·.·.·.·.Ú.....·...··.·L........... ........................... ........ .< « ......< ...... .» / 1, Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. SP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT - FS-3 GAS FLARING INCIDENT REPORT June 2003 Page 1 Iunplanned Events less than or equal to 1 hour . DATE· TIME· .. VOLUME . >DESCRIPTION OF tNCIDENT & CAUSE Not required for unplanned events which are less than or equal to 1 hour TOTAL o 'Unplanned Events weater than 1 hour DATE .. . TIME . . VOLUME· DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o I Iplanned Events Less Than or Equal 1 Hour AND Not Exceedin~ 5000 Mcf .DATE . . . TIME VOLUME .. DESCRIPTION OF INCIDENT & CAUSE· 6/7/2003 0700-0705 3 See attachments TOTAL 3 ~Planned Events ExceedinQ 1 Hour OR Exceeding 5000 Mcf . DATE·· . .. . TIME . .. VOLUME . DESCRIPTION OF INCIDENT & CAUSE· .. See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o 3 o 55,806 ~ ··ACTION TAKEN>TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO EUMINATE CAUSE· See attachments ACTION TAKEN TO EUMINATE CAUSE· See attachments . ACTION TAKEN TO EUMINATE CAUSE . . See attachments 7/9/2003 2: 17 PM FACILITY: FS3 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0365 BPXA FLARE REPORT PRUDHOE BAY DATE: 07 Jun 2003 TIME OF FLARING Start Stop Duration 07:00 07:05 OHrs 5Mìns First Determination of Cause: 1. 1801 T/C Shutdown for Maintenance (Borescope). 1802 T/C previously brought online. Action Taken to Stop Flaring: 1. 1801 Normal Shutdown. Thursday, June 26, 2003 Black Intermittent Smoke o 0 Planned TOTAL VOLUME ~ VOLUME 3 MSCF 3 MSCF Page 1 of 1 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 38,597 6. Used for lease operations Fuel 903,202 Assist 20,899 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 962,698 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 941,799 11. Transferred to: CCP 24,690,586 Remarks: I hereby cef) .that t~fOregOjng is true and correct to the best of my knowledge. Signature: . a... 1 "....At. JJ ~ Title: SUPERVISOR - Facility FLOW STATION 3 Form 10 422 (Revised 4/95) ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION perator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 07/2003 *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. SP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT - FS-3 GAS FLARING INCIDENT REPORT July 2003 Page 1 runplanned Events less than or equal to 1 hour DATETJME VOWME DESCR,IPTIONOFINCIDENT&CAUSE. Not required for unplanned events which are less than or equal to 1 hour TOTAL o I ,unplanned Events greater than 1 hour DATE TIME . . VOLUME DESCfitPTJON OF INCIDENT & CAUSE See attachments TOTAL o I ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mef DATE . TIME·· .. VoLUME .. DESCRIPTION OFINCIPENT & CAUSE See attachments TOTAL o I Iplanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf PATE TIME VOLUME . DESCRIPTION OF INCIDENT & CAUSE· See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o o 59,496 . AÇTION TAf{ENTO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour . ACTiON TAKEN TO ELIMINATE CAUSE See attachments . . ACTION TAKEN TO ELIMINATE CAUSE·. .... . See attachments ACTION TAKEN TO ELIMINATE CAUSE. See attachments 8/11/2003 1:15 PM Facility ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 08/2003 FLOW STATION 3 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 6 4. Flared or vented greater than 1 hour 7,675 ./ (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 39,089 6. Used for lease operations Fuel 910,111 Assist 22,036 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 978,917 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 949,200 11. Transferred to: CCP 25,764,124 Remarks: I hereby ce~ot r fOregOin1J true and correct to the best of my knowledge. Signature: ~ . -Á. A MfA Title: SUPERVISOR Form 10-422 (RevIsed 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety 7¡{o7.5"MCF ~ 2. Lease Use MCF 3. Conserv. Purposes MCF ~~ Commissioner /~~Ol Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· FS-3 GAS FLARING INCIDENT REPORT August 2003 Page 1 Unplanned Events less than or equal to 1 hour 8/9/2003 1230-1235 3 Not required for unplanned events which are less than or equal to 1 hour Not required for unplanned events which are less than or equal to 1 hour TOTAL 3 8/15/2003 1350-1535 7,675 See attachments See attachments TOTAL 7,675 ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf . ··ÞATE. ..... .... .. ·T1M~ ....... .. . VOL(JN!E ... . DE$CRIPTION OF INCIDENT & CAUSE ... . .. 8/10/2003 1350-1355 3 See attachments . . ACT,ONTAKENTOELIMINATECA(JSE .. . See attachments J TOTAL 3 See attachments See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 7,675 3 o 68,806 9/9/2003 9:04 AM FACILITY: FS3 SYSTEM 1. Flare/Relief Valve BPXA FLARE REPORT PRUDHOE BAY DATE: 10 Aug 2003 TIME OF FLARING Start Stop Duration 13:50 13:55 OHrs 5Mins First Determination of Cause: 1. Shut down 1802 tic after test run after maintenance. Action Taken to Stop Flaring: 1. Normal compressor and piping blowdown·votume. Thursday, August 21, 2003 REPORT NO: 03-0476 Black Intermittent Smoke Planned o o TOTAL VOLUME ~ VOLUME 3 )tMSCF 3 )Y'MSCF Page 1 of 1 REPORT NO: 03-0485 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 15 Aug 2003 SYSTEM 1. Flare/Relief Valve TIME OF FLARING Start Stop Duration 13:50 15:35 1 Hrs 45Mins Black Intermittent Smoke ~ 0 Planned VOLUME o 7,675 MSCF TOTAL VOLUME 7,675 MSCF First Determination of Cause: 1. POWER FAILURE WHILE REPLACING REBUILT MAIN ELECTRICAL BREAKERS CAUSING LOSS OF COMPRESSOR. Action Taken to Stop. Flaring: 1. REDUCED RATES INCOMING TO PLANT WHILE ELECTRICAL REPAIRS AND INSTRUMENTION REPAIRS WERE MADE. COMPRESSOR WAS DEPRESSURED AND SECURED. Thursday, August 21, 2003 Page 1 of 1 Facility FLOW STATION 3 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 09/2003 Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 PRUDHOE 640150 100.00% 3. Flared or vented less than 1 hour. 364 4. Flared or vented greater than 1 hour 177 V (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 38,070 6. Used for lease operations Fuel 897,250 Assist 24,588 7. Other Lift Gas, Off Field 0 :.~ ··············.·ii ..,;.;........> ...................... . ........................ ...... .«. TOTAL items 1 - 7 960,449 1. Safety \ 77 MCF 8. NGL gas equivalent produced 0 2. Lease Use MCF 9. Purchased gas 0 3. Conserv. Purposes MCF 10. Transferred from: CGF 935,320 vff~ /l/Í 0/3 Com~ioner r Date 11. Transferred to: CCP 27,571,378 Note: All volumes must be corrected to pressure of 14.65 Remarks: psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. I hereby ce{j that thrOregOi~~S true and correct to the best of my knowledge. Authority 20 AAC 25.235. Signature: () . .A.A "'" D J Title: SUPERVISOR , Form 10-422 (Revised 4/95) 3~ BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT· FS-3 GAS FLARING INCIDENT REPORT September 2003 Page 1 ~Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT &:CAUSE 9/5/2003 1545-1550 3 Not required for unplanned events which 9/5/2003 1620-1623 32 are less than or equal to 1 hour 9/6/2003 1230-1235 3 9/6/2003 1344-1346 14 9/14/2003 0250-0255 60 TOTAL 112 ACTION TAKEN TO ELlMINA'TE CAUSE Not required for unplanned events which are less than or equal to 1 hour ~Unplanned Events ~reater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT &: CAUSE 9/7/2003 1448-1453 3 See attachments 9/7/2003 1540-1545 3 9/13/2003 0157-0200 60 9/13/2003 1330-1430 33 9/19/2003 0505-0510 60 9/14/2003 0340-0345 60 9/14/2003 1030-1130 33 TOTAL 252 ~Planned Events Exceedin~ 1 Hour OR Exceedin~ 5000 Mct DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 9/13/2003 0215-0515 77 See attachments 9/14/2003 0355-0655 100 TOTAL 177 Unplanned Events < 1 Hour Unplanned Events> 1 Hour 0 Planned Events < 1 hour and not 252 exceeding 5,000 MCF Planned Events> 1 hour or 177 exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 63,199 ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELlMINA'TE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 10/7/2003 10:27 AM REPORT NO: 03-0507 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 07 Sep 2003 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve TIME OF FLARING Black Start Stop Duration Intermittent Smoke Planned VOt.:.ifME 14:48 14:53 OHrs 5Mins 0 0 ~ 3 MSCF 15:40 15:45 OHrs 5Mins 0 0 ~ 3 MSCF TOTAL VOLUME ûc1M)Cf First Determination of Cause: 1. 1802 TIC Shutdown - Maintenance/Operational test of ESD Shutdown Logic. 2. 1802 T/C Normal Shutdown after Instrumention maintenance. Action Taken to Stop Flaring: 1. Normal compressor and piping depressuring. 2. Normal compressor and piping depressuring. Tuesday, September 23,2003 Page 1 of 1 REPORT NO: 03-0521 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 13 Sep 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 01:57 02:00 OHrs 3Mins 0 0 ~ 60 MSCF 2. Flare/Relief Valve 02:15 05:15 3Hrs OMins 0 0 ~ 77 MSCF 3. Flare/Relief Valve 13:30 14:30· 1 Hrs OMiAS 0 0 ~ 33 MSGF TOTAL VOLUME 170 MSCF First Determination of Cause: 1. SHUT DOWN 1803 TIC FOR SCHEDULED MAINT. WORK 2. 1803 TIC SPIN COOLED FOR MAl NT. WORK 3. 1803 TIC SPUN FOR SPRING WATER WASHING FOR MAl NT. USED INCIDENT FOR REQUIRED OPACITY TESTING OF FLARE SYSTEM. Action Taken to Stop Flaring: 1. EQUIPMENT DEPRESSURED AND SECURED 2. SPIN COOLING COMPLETED AND MACHINE SECURED 3. WATER WASHING AND OPACITY TESTING COMPLETED AND MACHINE SECURED. Tuesday, September 23, 2003 Page 1 of 1 REPORT NO: 03-0549 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 14 Sep 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 02:50 02:55 OHrs 5Mins 0 0 0 60 MSCF 2. Flare/Relief Valve 03:40 03:45 OHrs 5Mins 0 0 ~ 60 MSCF 3. Flare/Relief Valve 03:55 06:55 3Hrs OMins 0 0 ~ ..100MSCF 4. Flare/Relief Valve 10:30 11:30 1 Hrs OMins 0 0 ~ 33 MSCF TOT AL VOLUME 253 MSCF First Determination of Cause: 1. 1803 Compressor tripped during startup 2. Shutdown 1804 Vc for maintenance 3. Cranking 1804 for cooldown to work on unit 4. 1804 turbine cranked for waterwash Action Taken to Stop Flaring: 1. Restarted machine 2. Depressured and secured for work 3. Stopped cranking when cooled down 4. Wash completed Thursday, October 02, 2003 Page 1 of 1 FACILITY: FS3 SYSTEM 1. Flare/Relief Valve REPORT NO: 03-0535 BPXA FLARE REPORT PRUDHOE BAY DATE: ~sep 2003 TIME OF FLARING Start Stop Duration 05:05 05:10 OHrs 5Mins Black Intermittent Smoke Planned o 0 ~ TOTAL VOLUME First Determination of Cause: 1. 1803 T/C SHUT DOWN FOR MAINTENANCE. COMPRESSOR WAS DEPRESSURED. Action Taken to Stop Flaring: 1. MACHINE WAS SHUTDOWN AND SECURED. Tuesday, September 23,2003 VOI::.t.JME 60 MSCF 60 MSCF Page 1 of 1 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 395 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 39,386 6. Used for lease operations Fuel 937,744 Assist 23,417 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 1,000,942 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 977,130 11. Transferred to: CCP 33,133,098 Remarks: I hereby cer:¿.r!/ thlfOreg~iS true and correct to the best of my knowledge. Signature:. .Å A '..J I Title: SUPERVISOR , Facility FLOW STATION 3 Form 10-422 (Revised 4/95) ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 10/2003 *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. SP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT· FS-3 GAS FLARING INCIDENT REPORT October 2003 Page 1 ~UnPlanned Events less than or equal to 1 hour DATE.· TIME· . ·YOLUME . DESCRIPTION OF INCIDENT & CAUSE Not required for unplanned events which are less than or equal to 1 hour . . AÇTION TAKEN TO,ELlt4lf11ATE CAUSE . . . . Not required for unplanned events which are less than or equal to 1 hour , TOTAL o Iunplanned Events ~reater than 1 hour ·.DATE ··TlME ·YOLUME .... DESCRIPTION QFINCIDEfIIT& CAUSE· . See attachments ... ... ... ACTION TA,KEN TO ELlMltliATE CAUSE ........ . . See attachments ~ TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE .. ··T'ME .... VOLUME ·.DESCR'PTlONOFJ!ilClpENl:&:CAUSE .. 10/28/2003 0245-0250 240 See attachments 10/28/2003 0630-0635 155 .. .. .. ACTJON,TAKEN TO ELIMINATE CAUSE .. ..... . See attachments . . ~ TOTAL 395 Planned Events Exceeding 1 Hour OR Exceedin See attachments See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME o o 395 o 63,198 11/7/2003 1 :54 PM FACILITY: FS3 SYSTEM 1. Flare/Relief Valve 2. Flare/Relief Valve REPORT NO: 03-0598 BPXA FLARE REPORT PRUDHOE BAY DATE: 28 Oct 2003 TIME OF FLARING Start Stop Duration 02:45 02:50 0 Hrs 06:30 06:35 0 Hrs First Determination of Cause: 1. Planned shutdown for water wash of 1806. 2. Shutdown 1806 Vc after cooling spin. Action Taken to Stop Flaring: 1. Normal compressor and piping blowdown. 2. Normal blowdown volume for sid on crank. Thursday, October 30, 2003 Black Intermittent Smoke 5Mins 0 0 5Mins 0 0 Planned ~ ~ TOTAL VOLUME VOLUME 240 MSCF 155 MSCF 395 MSCF Page 1 of 1 ~ Facility FLOW STATION 3 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 11/2003 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 719 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 39,474 6. Used for lease operations Fuel 965,508 Assist 16,549 7. Other Lift Gas, Off Field 0 TOTAL items 1 - 7 1,022,250 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 1,004,982 11. Transferred to: CCP 32,697,816 Remarks: I hereby ceTI Ût te for~ is true and correct to the best of my knowledge. Signature: ."'" A L2 Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 MC 25.235. SP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT - FS-3 GAS FLARING INCIDENT REPORT November 2003 ~UnPlanned Events less than or equal to 1 hour DATE . TIME . ... V9LUME . DESCRIPTION OF INCIDENT & CAUSE 11/16/2003 0350-0450 256 Not required for unplanned events which 11/16/2003 2310-2330 89 are less than or equal to 1 hour Page 1 TOTAL 345 Iunplanned Events greater than 1 hour .. DATE. . <riME>·· ·V9LUME ·PESCRIPTIQN Of' INCIDEN'J'& CAUSE·· See attachments TOTAL o ~Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf .. .. .DATE· .. TIME.. .. . VOLUME . DESCRIPTION OF INCIDENT & CAUSE . 11/26/2003 0930-1015 374 See attachments TOTAL 374 ~Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf .. ... ..DATE ...... .. ..... ··T ME . ·······VOLUME.·· DESCRIPTION OF INCIDENT .& CAUSE· See attachments TOTAL o Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 345 o 374 o 56,742 . ... ACTION TAKEN TO EI,.IMINATECAUSE Not required for unplanned events which are less than or equal to 1 hour . ACTION TAKEN TO ELIMINATE CAUSE .. See attachments . ACTION TAKEN TO ELIMINATE CAUSE·· .."......-........-'.-,"....,...-............'...,... See attachments ~ . ACTION TAKENTQ ELIMINATe CAUSE See attachments 12/5/2003 10:22 AM REPORT NO: 03-0646 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 26 Nov 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 09:30 10:15 OHrs 45Mins 0 0 ~ 374 MSCF TOTAL VOLUME 374"MSCf First Determination of Cause: 1. Portion of EONW OA AL Tieline depressured to enable welding on line in support of F448A V AL Bypass installation. Action Taken to Stop Flaring: 1. Completed depressuring to desired pressure. Monday, December 01, 2003 Page 1 of 1 " Facility FLOW STATION 3 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Operator Field(s) Month/Year of Disposition BP EXPLORATION, ALASKA EASTERN OPERATING AREA-PBU 12/2003 Disposition Volume MCF* 1. Sold 0 2. Reinjected 0 3. Flared or vented less than 1 hour. 492 4. Flared or vented greater than 1 hour 0 (Supplemental report required - See 20 AAC 25.235) 5. Pilot and Purge 39,862 6. Used for lease operations Fuel 1,013,345 Assist 72 7. Other Lift Gas, Off Field 0 TOTAL items 1 . 7 1,053,771 8. NGL gas equivalent produced 0 9. Purchased gas 0 10. Transferred from: CGF 1,053,207 11. Transferred to: CCP 34,614,502 Remarks: I hereby cert~:().t~fOregOin~iS true and correct to the best of my knowledge. Signature: 1 A/III IJ Title: SUPERVISOR Form 10-422 (Revised 4/95) *Indicate contribution of each pool to total. Pool Name Code Percent PRUDHOE 640150 100.00% 1. Safety MCF 2. Lease Use MCF 3. Conserv. Purposes MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-3 GAS FLARING INCIDENT REPORT December 2003 Page 1 TOTAL Not required for unplanned events which are less than or equal to 1 hour o Not required for unplanned events which are less than or equal to 1 hour IUnplanned Events greater than 1 hour DATE TIME VOLUME TOTAL DESCRIPTION OF INCIDENT & CAUSE See attachments Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf o 12/1/2003 12/2/2003 12/3/2003 1630-1635 1345-1430 0515-1915 TOTAL 3 See attachments 374 115 492 Planned Events Exceedin 1 Hour OR Exceeding 5000 Mcf TOTAL Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events> 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 40,426 See attachments o o o 492 o ACTION TAKEN TO ELIMINATE CAUSE See attachments See attachments See attachments 1/6/2004 3:45 PM REPORT NO: 03-0650 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 01 Dee 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 16:30 16:35 OHrs 5Mins 0 D ~·'''8'MSGf TOTAL VOLUME 3 MSCF First Determination of Cause: 1. 1801 T/C normal shutdown due to accumulated run hours. Action Taken to Stop Flaring: 1. 1801 normalshutdown. Thursday, December 18, 2003 Page 1 of 1 REPORT NO: 03-0651 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 02 Dee 2003 TIME OF FLARING Black SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Controlled Blowdow 13:45 14:30 OHrs 45Mins D D ~ 374M6GF TOTAL VOLUME 374 MSCF First Determination of Cause: 1. Portion of EOA/WOA AL Tieline was depœssured so that the line could be hot tapped for F448 AL bypass installation. Action Taken to Stop Flaring: 1. Completed depressuring at desired pressure. Thursday, December 18, 2003 Page 1 of 1 REPORT NO: 03-0652 BPXA FLARE REPORT PRUDHOE BAY FACILITY: FS3 DATE: 03 Dee 2003 TIME OF FLARING Slack SYSTEM Start Stop Duration Intermittent Smoke Planned VOLUME 1. Flare/Relief Valve 05:15 19:15 14Hrs OMins 0 0 ~ 145 MSGF TOTAL VOLUME 115 MSCF First Determination of Cause: 1. Depressure 14B/C common line to do a corrosion inspection near the DS14 Pig receiver. Action Taken to Stop Flaring: 1. Completed corrosion inspection aAEI·oocmalledt:Jpthe 14B/C common line. Thursday, December 18, 2003 Page 1 of 1