Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutKRU CPF 1 / Conoco Phillips STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2004 FACILITY: KRU CPF 1 OPERATOR: CONOCOPHILLIPS ALASKA OIL AND GAS CONSERV A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility I~perator iield(S) MonthIY ear of Disposition CENTRAL PROCESSING FACILITY #1 CONOCOPHILLIPS ALASKA. INC. KUPARUK RIVER UNIT 1/04 Disposition Volume MCF* *Indicate contribution of each pool to total. 1. Sold 1 1.897 Pool Name Code Percent 2. Reinjected 2,981,444 KUPARUK RIVER UNIT 490100 98.52% 3. Flared or vented less than 1 hour 1,192 KRU WEST SAK 490150 1.48% 4. Flared or vented greater than 1 hour 0 lSuoolemental reoort reouired--See 20 AAC 25.235' 5. Pilot and Purge 12.261 6. Used for lease operations Fuel 92~.~~~ A__j_t 7. Other 0 Official Use Only--Flaring Authorization> 1 hr. TOTAL items 1 -7 3.941.798 1. Safety MCF 8. NGL gas eauivalent produced 0 2. Lease Use MCF 9. Purchased gas 0 3. Conserv. Purposes MCF 10. Transferred from: PBU CGF (LSEOR NGLS) 150.206 Commissioner Date 11. Transferred to: CPF 3 0 CPF2 1,126,102 Note: All volumes must be corrected to Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR pressure of 14.65 psia and to a temperature of reflected on line 10 or Naptha used in SSEOR meter #201 60 degrees F. Report due by the 20th of the I hereby certify that the foregoing is true and correct to the best of my knowledge. month following the month of disposition. Signature: '-771.f,t~ 8-Þ-o/O r Authority 20 AAC 25.235. Title: Supervisor Form 10-422 (Revised 4/95) .. ~ DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE CONOCOPHILLIPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 JANUARY 2004 PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Piiot and Purge TOTALFLAREDIVENTED o o o 1,192 6,820 12.261 20,273 1. Facility Number I?' Facility Name 3. Field I~' Operator ]5.MonthlYear of Disposition 0290000021 CENTRAL PROCESSING FACILITY #1 KUP ARUK RIVER UNIT CONOCOPHILLIPS ALASKA, INC. 2/04 Disposition Volume MCF* 20. For production from multiple pools. list contribution of each Dool as a lJ¡ rcent of Total Volume. 6. Sold 11.367 Pool Name Code Percent 7. Reinjected 2,511,762 KUPARUK RIVER UNIT 490100 96.08% 8. Flared or vented less than 1 hour 2,773 KRU WEST SAK 490150 3.92% 9. Flared or vented greater than I hour 37 1/ lSunnlemental reoort reauired--See 20 AAC 25.235) 10. Pilot and Purge 12.946 11. Used for lease operations AFuel 77HA~ l..i.t 12. Other 0 Official Use Only Autnonzatlon > 1 nr: Safety '37 MCF 13. TOTAL VOLUME (ITEMS 6-12) 3.318.606 Lease Use MCF 14. NGL gas eauivalent produced 0 Conservation MCF 15. Purchased gas 0 Wa$te; .ð MCF 16. Transferred from: PBU CGF (LSEOR NGLS) 208.412 //.~ I-Ip!r¡- 'lV?' '/ Commissioner Date 17. Transferred to: CPF 3 0 CPF2 (678,164) Note: All volumes must be corrected to pressure of 14.65 psia 18. Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR and to a temperature of 60 degrees F. Report due by the 20th reflected on line 10 or Nantha used in SSEOR meter #201 60 degrees F. Report due by the 20th of the month following I hereby certify that the foregoing is true and correct to the best of my knowledge. the month of disposition. Signature: Jtl ~þ hlJJc.u Authority 20 MC 25.235. Title: Supervisor $//1/0 ,¡ Printed Name: S. e..eb{¡f)~ ...Lw d, bd4Phone: 263-4121 Date - I . . /'" ..~ Form 10 422 (RevIsed 1/2004) STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION .-.-: 08ß- SubmIt m Duplicate ·~ . CONOCOPHiLLlPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 FEBRUARY 2004 DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE PLANNED UNPLANNED ACTION TAKEN TO ELiMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR 2/28/2004 0401-0714 TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Fiare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTALFLAREDIVENTED 37 37 o Leak in KUTP O/H cond.-need to maintain positive psi while tower cooled whiie depressuring to flare 37 2,773 5,906 W§ 21,662 Unpianned Shutdown KUTP and cooled tower ;1'1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION I. Facility Number 0290000021 2. Facility Name CENTRAL PROCESSING FACILITY #1 3. Field 4, Operator 5.Month/Year of Disposition KUPARUK RIVER UNIT CONOCOPHILLIPS ALASKA, INC, 3/04 Disposition Volume MCF* 6. Sold 11. 773 7. Reinjected 2,762,102 8. Flared or vented less than 1 hour 1,082 9. Flared or vented greater than I hour 0 (SuDolemental reoort reauired--See 20 AAC 25,235) 10. Pilot and Purge 15.135 11. Used for lease operations Fuel 903. 7~8 Assist 623 12. Other 0 13. TOTAL VOLUME (ITEMS 6-12) 3.700.031 14, NGL!!as eauivalent oroduced 0 15. Purchased gas 0 16. Transferred nom: PBU CGF (LSEOR NGLS) 247.991 17. Transferred to: CPF 3 0 CPF2 (733,027) 18. Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR reflected on line 16 or Naotha used in SSEOR meter #201 I hereby certifY that the foregoing is true and correct to the best of my knowledge. Signature: ~~ ~ Title: Supervisor Printed Name: $./?'.£6Wk1Z/H"¡;"'- UÎ:>¡/(¡j>hone: 263-4121 Date th í-ðjtJ;j Form 10-422 evised 1/2004 I (R 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. Pool Name Code Percent KUPARUK RIVER UNIT 490100 96.89% KRU WEST SAK 490150 3,11% Official Use Only Autnonzatlon > 1 nr: Safety MCF Lease Use MCF Conservation MCF Waste: MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25,235. Submit in Duplicate ~ DATE TIME VOLUME MCF DESCRIPTiON OF INCiDENTS & CAUSE CONOCOPHILLIPS ALASKA, iNC. CONSERVATiON ORDER NO. 219 GAS FLARING OR VENTiNG iNCiDENTS CPF #1 MARCH 2004 PLANNED UNPLANNED ACTiON TAKEN TO ELIMINATE CAUSE FLARiNG OR VENTiNG EVENTS GREATER THAN 1 HOUR TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTAL FLAREDNENTED o o o 1,082 6,239 15,135 22456 [Fwd: CPFl Flaring Event] -------- Original Message -------- CPF1 Flaring Event Sun, 29 Feb 2004 06:49:15 -0900 NS K Env Proj:::~~_º- 3 7 @con~?.E..J:1:D_~_~I2E;_.:s::<?_m > Jim Regg (E-mail) 5Jim re9g@a~~.:i:~.:state:ak:_1,l_~'::: CPF1 Prod Supv :nl132@co~~~ophilli.~~com> Subject: Date: From: To: CC: Jim: Just a FYI: At 3:15 am yesterday, we discovered a naptha leak from the overhead condenser at the Kuparuk Topping Plant. The unit was shut down, and the condenser was bled down. As a result, we flared for 3 hours and 35 minutes with a volume of 373 MSCF. If you have any questions or want more information, give me a call. Jeff Smith Kuparuk Senior Environmental Coordinator 907/659-7242 n 103 7 ~cC?!,.:..c:JS::.c?12..~_~l.-i.E§ . com 1 of 1 3/2/20048:19 AM 1. Facility Number 0290000021 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 2. Facility Name CENTRAL PROCESSING FACILITY #1 3. Field 4. Operator 5.Month/Year of Disposition KUP ARUK RIVER UNIT CONOCOPHILLIPS ALASKA, INC. 4/04 Disposition Volume MCF* 6, Sold 11.574 7. Reinjected 2,481,573 8. Flared or vented less than I hour 835 9. Flared or vented greater than 1 hour 0 (Suoolemental reoort required-oSee 20 AAC 25.235) 10. Pilot and Purge 13.282 11. Used for lease operations Fuel 89~.~~~ A.sist 12, Other 0 13. TOTAL VOLUME (ITEMS 6-12) 3.409.464 14. NGL gas eauivalent nroduced 0 IS. Purchased gas 0 16, Transferred from: PBU CGF (LSEOR NGLS) 241.327 17. Transferred to: CPF 3 0 CPF2 (567,502) 18. Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR reflected on line 16 or Naptha used in SSEOR meter #201 I hereby certifY that the foregoing is true and correct to the best of my knowledge. Signature: ~~ Title: Sunervisor 5/11/0'1 Printed Name: ^/ot:...1 ì:>¡/(c.. Phone: 263-4121 Date Form 10-422 (Revised 1/2004) 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. Pool Name Code Percent KUPARUK RIVER UNIT 490100 97.05% KRU WEST SAK 490150 2.95% Official Use Only AUthOrIZatIon> 1 nr: Safety MCF Lease Use MCF Conservation MCF Waste: MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Submit in Duplicate CONOCOPHILLIPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 MARCH 2004 DATE TIME VOLUME MCF DESCRIPTION OF INCiDENTS & CAUSE PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARiNG OR VENTiNG EVENTS GREATER THAN 1 HOUR TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Voiumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTALFLAREDNENTED o o o 19,956 1. Facility Number 0290000021 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 2. Facility Name CENTRAL PROCESSING FACILITY #1 3. Field 4. Operator 5.MonthlYear of Disposition KUP ARUK RIVER UNIT CONOCOPHILLIPS ALASKA, INC. 5/04 Disposition Volume MCF* 6. Sold 12.126 7. Reinjected 2,753,574 8. Flared or vented less than 1 hour 2,383 9. Flared or vented greater than 1 hour 0 (Suoolemental reoort reouired--See 20 AAC 25.235) 10, Pilot and Purge 13.021 11. Used for lease operations Fuel 81~.¡~~ Asoiot 12. Other 0 , 13. TOTAL VOLUME (ITEMS 6-12) 3.603.197. 14. NGL gas eauivalent Droduced 0 15. Purchased gas 0 16. Transferred from: PBU CGF (LSEOR NGLS) 258.000,. 17. Transferred to: CPF 3 0 CPF2 (812,005) 18. Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR reflected on line 16 or Naptha used in SSEOR meter #201 I hereby cert~regoing is true apd correct to the best of my knowledge. Signature: JW~ Title: Supervisor I vll.5/o¥ Printed Name: Noel Dike Phone: 263-4121 Date Form 10-422 (RevIsed 1/2004) 20. For production from multiple pools. list contribution of each pool as a percent QfTotal Volume. Pool Name Code Percent KUPARUK RIVER UNIT 490100 96.60% KRU WEST SAK 490150 3.40% Official Use Only AutnonzatIon > 1 nr: Safety MCF Lease Use MCF Conservation MCF Waste: MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Report due by the 20th of the month following the month of disposition. Authority 20 AAC 25.235. Submit in Duplicate DATE TIME PLANNED UNPLANNED ACTION TAKEN TO ELIMiNATE CAUSE CONOCOPHILLIPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARiNG OR VENTING iNCiDENTS CPF #1 MAY 2004 FLARiNG OR VENTiNG EVENTS GREATER THAN 1 HOUR VOLUME MCF DESCRIPTION OF iNCIDENTS & CAUSE TOTAL OVER 1 HOUR o PLANNED EVENTS LESS THAN 1 HOUR Fiare or Vent Voiumes: Greater than 1 hour Less than 1 hour Continuous Assist Piiot and Purge TOTALFLAREDNENTED o o 2,383 '&II''''~>::._I 13.021 21,290 STATE OF ALASKA ALASKA OIL AND GAS CONSER V A TION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1,2. Facility Name 3. Field 14. Operator is.Month/Year of Disposition 0290000021 CENTRAL PROCESSING FACILITY #1 KUPARUK RIVER UNIT CONOCOPHlLLIPS ALASKA, INC. 6/04 Disposition Volume MCF* 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. Pool 6. Sold 11.327 Pool Name Code Percent 7. Reinjected 2,914,601 KUPARUK RIVER UNIT 490100 98.24% 8. Flared or vented less than 1 hour 4,198 KRU WEST SAK 490150 1.76% 9. Flared or vented greater than 1 hour 0 (see instructions) 10. Pilot and Purge 14.086 11. Used for lease operations A ~~~~ 79H~¡ (sÅ“cifv in Remark;) 12. Other 0 Official Use Only (see instructions) AuthonzaUon > 1 he: Safety MCF 13. TOTAL VOLUME (ITEMS 6-12) 3,747,358 Lease Use MCF 14. NGL e:as eauivalent 0 Conservation MCF 15. Purchased gas 0 Waste: MCF 16. Transferred from: PBU CGF (LSEOR NGLS) 278.011 Commissioner Date 17. Transferred to (expressed as a negative #): CPF 3 0 CPF2 11,065,678) Note: All volumes must be corrected to pressure of 14.65 psia 18. Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR and to a temperature of 60 degrees F. reflected on line 16 or NaPtha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:..j,ßt~ Þ ~ Authority 20 MC 25.235. Title: Sunervisor Printed Name: Noel Dike Phone: 263-4121 Date "1/ /1/ Ð 1 Form 10-422 (Revised 4/2004) Submit in Duplicate CONOCOPHILLlPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 JUNE 2004 DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTiNG EVENTS GREATER THAN 1 HOUR TOTAL OVER 1 HOUR o PLANNED EVENTS LESS THAN 1 HOUR o Fiare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge o 4,198 5,764 14.086 TOTALFLAREDIVENTED 24,048 Disposition Volume MCF* 6. Sold 9.067 7. Reinjected 2,549,810 8. Flared or vented less than 1 hour 5,735 9. Flared or vented greater than 1 hour 9.858 .- V (see instructions) 10. Pilot and Purge 13.546 11. ~~d for lease op~;ations A Fuel 78~:~g? s""r.ifv in Remarks ..o¡ ./ 12. Other 0 (see instructions) 13. TOTAL VOLUME (ITEMS 6-12) 3,377,370 14. NGL gas eauivalent 0 15. Purchased gas 0 16. Transferred from: PBU CGF (LSEOR NGLS) 219.074 17. Transferred to (expressed as a negative i): CPF 3 0 CPF2 (995,330) 18. Remarks: Reinjected vol does not include volumes of PBU NGLS aquired for LSEOR reflected on line 16 or Naptha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: -/71ff Á ~ Title: Supervisor Printed Name: Noel Dike Phone: 263-4121 Date 1. Facility Number 0290000021 Form 10-422 (Revised 4/2004) . STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 2. Facility Name CENTRAL PROCESSING FACILITY #1 3. Field 4. Operator 5.MonthIY ear of Disposition KUPARUKRIVER UNIT CONOCOPHIlLIPS ALASKA, INC. 7/04 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. Pool Pool Name Code Percent KUPARUK RIVER UNIT 490100 97.48% KRU WEST SAK 490150 2.52% Official Use Only AuthonzatlOn > 1 hr: q, <ß5ß MCF ,j ßp- Safety Lease Use MCF Conservation MCF MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Authority 20 AAC 25.235. Submit in Duplicate . . . . CONOCOPHiLLlPS ALASKA, INC. CONSERVATiON ORDER NO. 219 GAS FLARiNG OR VENTING INCiDENTS CPF #1 JUNE 2004 DATE TIME VOLUME MCF DESCRiPTiON OF iNCIDENTS & CAUSE PLANNED UNPLANNED ACTION TAKEN TO ELiMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR 7/14/2004 1408-1545 475 Excessive inlet gas rates into facility, high ambient temperature Planned Reducedlincreased inlet gas rates, 5113 wells and 2000+ SCPD as ambient temp increased. 7/16/2004 0637-0759 1,337 Excessivelinsufficient inlet gas rates into facility, facility Unplanned Reducedlincreased inlet gas rates, Repaired maintenance, gas lift compressor shutdown, thermocoupling equipment difficulties. problem 7/18/2004 1721-1919 1,817 Faulty shutdown on A GLC, gas lift compressor shutdown Unplanned Reduced/increased inlet gas rates, Repaired SurgeNibration equipment difficulties with A GLC, shut in 24 wells (54 MMSCFD) 7/28/2004 0550-0713 & 6,229 Facility maintenance, planned plant shutdown, NGL annubar Planned Facility maintenance completed. 0722-1619 malfunction TOTAL OVER 1 HOUR 9,858 PLANNED EVENTS LESS THAN 1 HOUR o Fiare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Piiot and Purge 9,858 5,735 7,191 13.546 TOTALFLAREDNENTED 36,330 . . . CPF-1 Shutdown Jim and Steve, Just wanted to give you a 'heads up' that we are scheduled to take down CPF-1 and associated drillsites at 6:00am on Weds, July 28th. The purpose of the shutdown is to replace inlet valves, perform upgrades for increased West Sak development, facilitate other mechanical integrity repairs and perform a test of the plant ESD system. In addition, the Primary Separator will be taken out of service for inspection and repair. We plan to bring the plant back on at 6:00am Monday, August 2nd. The primary separator will remain out of service for an additional 42 days. If you have any questions or require additional information, please do not hesitate to contact me. Leigh Leigh McDaniel and Jeff Smith Senior Field Environmental Coordinator - Kuparuk (907) 659-7242 Phone (907) 659-7712 Fax 1 öf 1 7/23/20048:18 AM " STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000021 2. Facility Name CENTRAL PROCESSING F ACillTY #1 3. Field KUP ARUKRIVER UNIT Disposition Volume MCF* 6. Sold 9,080 7. Reinjected 2,394,817 8. Flared or vented less than 1 hour 5,030 7,602, 10. Pilot and Purge 11,301 è Fuel Assi t 709,817 . 10 . o 12. Other (see instructions) 13. TOTAL VOLUME (ITEMS 6-12) 3,148,057 ' 14, NGL gas equivalent 15. Purchased gas 16. Transferred ÍÌ'om: PBU CGF (LSEOR NGLS) 2,903 17. Transferred to (expressed as a negative #): CPF 3 CPF2 18. Remarks: Reinjected vol does not include volumes ofPBUNGLS aquired for LSEOR reflected on line 16 or N a tha used in SSEOR meter #201 I hereby certifY that the foregoing is true and correct to the best of my knowledge. Signature: 77&.f1 ~ Title: Supervisor Printed Name: Noel Dike Form 10-422 (Revised 4/2004) Phone: 263-4121 'f In 10 Date Pool Name Percent KUP ARUK RIVER UNIT 490100 96.96% KRU WEST SAK 3.04% 490150 Official Use Only Authorization> 1 hr: Safety 7. ~O(,,-MCF ¡ Lease Use MCF o o Date MCF Waste: MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Authority 20 MC 25.235. Submit in Duplicate · ' DATE TIME CONOCOPHILLIPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR 8/1/2004 81212004 816/2004 8/24/2004 8/30/2004 08/30/2004- 08/31/2004 15:37-18:12,23:44-01:14 08-14-10:57 14:44-14:47, 15:28-16:40, 16:43-16:58 04:49-16:13 04:43-05:44 17:49-00:00,00:01-01:18 1,750 270 1,357 2,982 64 1179 Flaring for drillsite shutdpwnlstartup, Plant startup after turnaround, Bringing up production wells and gas handling equipment. Flaring for drillsite shutdownlstartup, Plant startup after Turnaround. The flare event caused black smoke because the smokeless flare is out of service for maintenance. At approximately 3:40 pm on 8/6, a Frame 3 Gas Lift Compressor went down, and the gas was sent to the McGill Emergency Flare. Black smoke was observed being emitted from the flare, and an EPA Method 9 observation was performed. As shown by the attached results, the opacity readings taken from the flare exceeded the limits specified by DPF1 Title V permit conditions 3(a) and 3(b). In order to reduce the volume of gas being sent to the McGill flare, a total of 19 wells were shut in. Electrical/lnstrumentation malfunction, a GLC tripped due to instrument malfunction Facility Maintenance, The plant needed to be shutdown and depressured to remove blinds from the primary separator. A plant blow down was initiated to depressure. The primary was taken down for planned maintenance. The blinds had been installed during the July 28 full plant shutdown. Facility maintenance, Process upset in gas section of facility, Flaring started during the depressuring of the nitrogen used for pressure testing and oxygen purging of the plant after a planned shutdown. 290,000 scf of the flare volume was this nitrogen. Unplanned Unplanned Unplanned Unplanned Planned Planned Stabilized facility process and operation Stabilized facility process and operation. Started/restarted TIC, Reduced/increased inlet gas rates, Stabilized facility process and operation. Startedlrestarted TIC # A GLC C2-101A, repaired equipment difficulties with A GLC, reduced/increased inlet gas rates, shut in wells for reduced rates and instrument techs repaired faulty switch. Facility maintenance completed, Completed the blow down. Stabilized facility process and operation, Facility maintenance completed, Competed facility startup. · . DATE TIME TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTALFLAREDIVENTED CONOCOPHILLlPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 :{{{,::):\):::::)::)):::):::\'(:::j:)):):)::mrf)"""):::):)Äiji¡~~:l.¢.t.ì.H):'::'::::)::(:")):)::):)::((:):::})(:f::::):)(:?):)::(:::i:::::::):):) VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE 7,602 PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE o .., 7,602 5,030 f):1Þ,i~~y.) 111301 34,343 1. Facility Number 0290000021 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 2. Facility Name CENTRAL PROCESSING F ACll.ITY #1 3. Field 4. Operator 5.MonthlYear of Disposition KUPARUKRIVER UNIT CONOCOPHllLIPS ALASKA, INC. 9/04 Disposition Volume MCF* 6. Sold 11,745 7. Reinjected 2,859,232 8. Flared or vented less than 1 hour 2,564 9. Flared or vented greater than 1 hour 0 (see instmctions) 10. Pilot and Purge 15,899 II. Used for lease o{:rations luel 8n,~~~ (soecifV in Remar s) ..oist 12. Other 0 (see instmctions) 13. TOTAL VOLUME (ITEMS 6-12) 3,769,163 14. NGL gas equivalent 0 15. Purchased gas 0 16. Transferred from: PBU CGF (LSEOR NGLS) 238,701 17. Transferred to (expressed as a negative #): CPF 3 0 CPF2 (1,092,273) 18. Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR reflected on line 16 or Naptha used in SSEOR meter #201 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature: t1 µt ~ Title: Supervisor 10 lIe¡ /tJlf Printed Name: Noel Dike Phone: 263-4121 Date , Form 10-422 (Revised 4/2004) 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. Pool Pool Name Code Percent KUP ARUK RIVER UNIT 490100 94.86% KRU WEST SAK 490150 5.14% Official Use Only Authorization> 1 hr: Safety MCF Lease Use MCF Conservation MCF Waste: MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Authority 20MC 25.235. Submit in Duplicate DATE TIME PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE CONOCOPHILLlPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 ::::::::::::::::::::::::::'¡'¡:¡¡¡:¡m¡¡¡:¡¡¡¡¡¡¡:¡¡¡::'¡:¡'¡'¡¡::¡':::¡:::::::::¡:¡¡:¡¡¡'¡¡~ip,-jimij:¡i!lt:::::::::::¡r¡¡r':'¡::::¡::¡¡:::::::':::::::::::::::::r:¡:¡¡¡:::¡¡¡::::::::::::::,: FLARING OR VENTING EVENTS GREATER THAN 1 HOUR VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTALFLAREDIVENTED o o o 2,564 :tt:':::tt::t:':r:tttM;~~~:: ..............................,........ 15,899 30,458 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 3. Field 4. Operator 5.MonthlYear of Disposition KUP ARUK RIVER UNIT CONOCOPHILLIPS ALASKA, INC. 10/04 20. For production from multiple pools, list contribution of each pool as a ercent 0 Total Volume. Pool Pool Name Code Percent 1. Facility Number 0290000021 2. Facility Name CENTRAL PROCESSING FACILITY #1 Disposition Volume MCF* 11,943 3,148,852 6,628 3,517 16,405 Fuel 892,251 Ass'st 38 0 4,093,467 0 0 238,841 6. Sold 7. Reinjected 8. Flared or vented less than 1 hour 10. Pilot and Purge 12. Other (see instructions) 13. TOTAL VOLUME (ITEMS 6-12) 14. NGL gas equivalent 15. Purchased gas 16. Transferred ITom: PBU CGF (LSEOR NGLS) 17. Transferred to (expressed as a negative #): CPF 3 o (1,178,989) CPF2 18, Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR reflected on line 16 or Na tha used in SSEOR meter #201 I hereby certiry that the foregoing is true and correct to the best of my knowledge. Signature: þ{lt~ -þ-; h.-ß-Jw Title: Supervisor Printed Name: Noel Dike Form 10-422 (Revised 4/2004) Phone: 263-4121 Date KUPARUKRIVER UNIT 490100 93.39% KRU WEST SAK 490150 6.61% Official Use Only Authorization> 1 hr: Safety 35'7 MCF d&e.-- MCF MCF MCF Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Authority 20MC 25.235. Submit in Duplicate DATE TIME CONOCOPHILLlPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 FLARING OR VENTING EVENTS GREATER THAN 1 HOUR VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE 101212004 00:23-01 :30 10/16/2004 18:38 - 20:09 TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTALFLAREDIVENTED 1,722 1,795 3,517 o 3,517 ,.,.,' ,tt::::!!::::::::~;¡¡~~! 16,405 40,421 SID TIC # C2-1 01 C for surge trip, Process upset in C2-1 01 C (Gas Lift Comp.), "C" GLC surged and shutdown. SID TIC # C2-101A for OSD. Process upset in C2-101A (Gas Lift Compressor), GLC-A tripped on High Temp 2nd Stage Thrust bearing. PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE Started/restarted TIC # C21 01 C, Reduced/increased inlet gas rates, Drillsite operators began cutting production. Unsuccessful attempt to restart within 56 minutes of shutdown. DS operators were cutting production of six wells when machine was successfully Unplanned restarted. Startedlrestarted TIC # C2-101A. Reduced/lncreased inlet gas rates. Shut in 44 wells after trip trying to Unplanned reduce/stop flare. - 1. Facility Number 0290000021 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 2. Facility Name CENTRAL PROCESSING F ACD..ITY #1 3. Field 4. Operator 5.Month/Y ear of Disposition KUPARUK RIVER UNIT CONOCOPHILLIPS ALASKA, INC. 11104 Disposition Volume MCF* 6. Sold 11.556 7. Reinjected 2,438,894 8. Flared or vented less than 1 hour 6,698 9. Flared or vented greater than 1 hour 0 (see instructions) 10. Pilot and Purge 14.471 11. ~~ed for lease oo~~ations AFuel 8R~~~ snecifv in Remarks ls.ist 12. Other 0 (see instructions) 13. TOTAL VOLUME (ITEMS 6·12) 3,312,360 14. NGL gas eauivalent 0 15. Purchased gas 0 16. Transferred from: PBU CGF (LSEOR NGLS) 207.975 17. Transferred to (expressed as a negative i): CPF 3 0 CPF2 (642,268) 18. Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR reflected on line 16 or Naotha used in SSEOR meter #201 I hereby certify that the foregoing is.true and correct to the best of my knowledge. Signature: 7)&f1 ~ Title: Supervisor Printed Name: Noel Dike Phone: 263-4121 Date /),//7/01 Form 10-422 (RevIsed 4/2004) 20. For production from multiple pools, list contribution of each ool as a ercent of Total Volume. Pool Pool Name Code Percent KUPARUK RIVER UNIT 490100 88.09% KRU WEST SAK 490150 11.91 % Official Use Only Authonzanon > 1 he: Safety MCF Lease Use MCF Conservation MCF Waste: MCF Commissioner Date Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Authority 20 MC 25.235. Submit in Duplicate .- CONOCOPHILLlPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS CPF #1 DATE TIME VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE PLANNED UNPLANNED FLARING OR VENTING EVENTS GREATER THAN 1 HOUR TOTAL OVER 1 HOUR o PLANNED EVENTS LESS THAN 1 HOUR o Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge o TOTALFLAREDNENTED 34,745 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000021 2. Facility Name CENTRAL PROCESSING FACILITY #1 3. Field 4. Operator 5.MonthIYear of Disposition KUPARUK RIVER UNIT CONOCOPHILLIPS ALASKA, INC. 12/04 Disposition VolumeMCF* 20. For production from multiple pools, list contribution of each 001 as a ercent of Total Volume. Pool Pool Name Code Percent 6. Sold 11.642 7. Reiqjected 2,557,155 KUPARUK RIVER UNIT 490100 89.80% 8. Flared or vented less than 1 hour 5,654 KRU WEST SAK 490150 10.20% 1.894 10. Pilot and Purge 15.479 Fuel 942.412 12. Other (see instructions) o Official Use Only Authonzauon > 1 he: Safety (, ß9~ MCF '£tv- 13. TOTAL VOLUME (ITEMS 6-12) 3,548,247 14. NGL I!as eauivalent o Lease Use MCF Conservation MCF 15. Purchased gas MCF 16. Transferred from: PBU CGF (LSEOR NGLS) 146.41 17. Transferred to (expressed as a negative i): CPF 3 CPF2 18. Remarks: Reinjected vol does not include volumes ofPBU NGLS aquired for LSEOR reflected on line 16 or Na tha used in SSEOR meter #201 I hereby certify that e foregoing is true and correct to the best of my knowledge. o (684,811) Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 degrees F. Signature: Authority 20 MC 25.235. Title: Su ervisor Printed Name: Noel Dike Form 10-422 (Revised 412004) Phone: 263-4121 Date 1/17/05 Submit in Duplicate , DATE TIME PLANNED UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE CONOCOPHILLIPS ALASKA, INC. CONSERVATION ORDER NO. 219 GAS FLARING OR VENTING INCIDENTS #1 VOLUME MCF DESCRIPTION OF INCIDENTS & CAUSE FLARING OR VENTING EVENTS GREATER THAN 1 HOUR 12/28/2004 20:03-21 :06 TOTAL OVER 1 HOUR PLANNED EVENTS LESS THAN 1 HOUR Flare or Vent Volumes: Greater than 1 hour Less than 1 hour Continuous Assist Pilot and Purge TOTAL FLAREDNENTED 1,894 1,894 o 37,038 SID TIC # C2-101A FOR Vib. Trip. Process upset in C2-101A section of the facility. AGLC SID on high vibration. "A" GLC Vibration trip. 1,894 Started/Restarted TIC # C2-101A. Reducedlincreased inlet gas rates. Drillsite operators cut production wells after one GLC start attempt at 20:15. Machine was successfully restarted after 58 minutes. Flare event Unplanned lasted sixty three minutes.