PBU FS 3 / BP
STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2007 FACILITY: PBU FS 3 OPERATOR: BP EXPLORATION Facility Number 0290000030 I 1. 2. Facility Name PBU FS 3 Field PBU - EOA 4. Operator I BP 5 MonttWSarol paposilon January-2007 Disposition Volume MCF 20. Fur production from multiple pods, list contribution of each pad as a percent of Total Volume. 8. Sold 0 Pod Name Pool Code Percent 7 ea 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour Or MSS 5,956 1 tour (see instr.) 0 9. Flared or vented more than 10. Pad and Purge 40,924 11. Used for lease operations (speed' In Remarks) 894,364 12. Other (see instructions) 0 Authorization >1 hr Sally MCF 13. TOTAL VOLUME STEMS 612) 941,244 Lease Use MCF 14. NGL Gas Equivalent 0 Conservation MCF 15. Purchased gas 0 Waste! MCF 18. Transferred from: CGF 934,785 Commissioner Dar 17. Transferred to: E as a negative CGF (Express rya n - 29,656,482 18. Remarks: Block 11: Fuel Gas = 893.861 mkt and Assist Gas = 503 react I hereby certify that the foregoing is true and correct to , best of my knowledge. Sgruaae ,h:_..... ` Title Manager, Production Taxes and Royalty Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. / � Printed Name Bemard W. Rainy Phone (907)584-5028 Date O2 7 ' e '07 Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate Unplanned Events less than or equal to 1 hour 1 DATE 1/4/2007 1/4/2007 1/9/2007 1/9/2007 1/11/2007 1/14/2007 1/29/2007 1/31/2007 1/31/2007 1/31/2007 ,.,: DATE — TIME VOLUME 0913 -0924 1436 -1509 0215 -0225 1525 -1610 1748 -1805 1435 -1455 1900 -1910 0210 -0230 0250-0255 0815 -0830 TOTAL 1 `Unplanned Events greater than 1 hour VOLUME _,. DESCRIPTION OF INCDENT 8 CAUSE,,,,.. See attachments TOTAL 1 (Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT 8 CAUSE 1/1/2007 0400-0415 32 See attachments 1/7/2007 0120- 0145 64 1/9/2007 0130-0140 60 1/11/2007 2030 -2035 240 TOTAL 396 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Met 1 THE TOTAL VOLUME 20 679 28 4,135 245 6 3 6 5,560 0 Unplanned Events < 1 How Unplanned Event > 1 Hour Planned Events < 1 Four and riot exceeding 5,000 MCF Planned Event > t hour or 0 exceeding 5,010 MCF Piot Purge WWI 40,924 Assist r 503 TOTAL FLARED VOLUME 47,383 0 TOTAL 5.560 0 396 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UM!' - FS-3 GAS FLARING INCIDENT REPORT January 2007 DESCRIPTION OF INCIDENT • CAUSE - - .. 8 Not required for unplanned events which 430 are less than or equal to 1 hour DESCRIPTION OF INIDENT 8 CAUSE See attachments .,,. ACTION TAKEN TO ELIMINATE CAUSE ; .,. ice Not required for unplanned events which are less than or equal to 1 hour , ACTION TAKEN TO ELIMINATE CAUSE „ „ „„„, „,„„„„ „, See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE,: ..n,m„mmuenw See attachments Page 1 211112007 3:00 PM Flare Start Date 1/1/2007 Flare End Date 1/31/2007 Report 07 -1 Controlled Slowdown 07 -11 Flare Relief 1/7/2007 1:20:00 AM 1:45:00 AM 25 minutes 07 -25 Other FS3 Flare Report Time Of Flaring Date Start Time Stop Time Duration Intermittent Black Smoke Planned 1/1/2007 4:00:00 AM 4:15:00 AM 15 minutes No Action Taken Determination Cause Action Taken Action Taken No Yes Determination Cause 1806 AL T/C case depressuring to 0 psi after shutdown for repair work on 1806 recycle valve. Depressured suction piping to AL suction scrubber. 1806 AL T/C shutdown, depressured and secured. No No Yes T1C 1804 shutdown for planned maintenance, depressured to 0 pressure to repair an LPS Suction cooler tube leak. Shut M 7 -36, 7-37, 7 -5, 7 -17, 7.21, 15 -18, 15 -5, 15 -46 and completed depressunng T/C and suction scrubber. 07-16 Flare Relief 1/9/2007 1:30:00 AM 1:40:00 AM 10 minutes No No Yes Determination Cause Pressured up 1804 T/C system to 100 psig for a pressure heck on the lin tan tubes after plugging a ruptured tube. Depressured to 0 psig to tighten up a tube sheet plug that was leaking. Completed depressuring the 1804 T/C system to 0 psig. 1/11/2007 8:30:00 PM 8:35:00 PM 5 minutes No No Yes Determination Cause 1806 T/C atoned start due to Turbine logic not being satisfied. Action Taken 1806 T/C normal depressuring of comp case during shutdown. Reported By Volume (MSCF) BP111OGANPD BPIIPRESLEDK BPIIPRESLEDK BPIIFAINDT 32 64 60 240 1. Facility Number 0290000030 2 Facility Name PBU FS 3 3. Field PBU - EOA 4. Operator 15. BP February-2007 Month/Year al Disposition 01 each pool as percent of Disposition Volume MCF / / / I 20. For production from multiple pools, list contribution Total Volume. 8. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% a. Flared or vented 1 hour or less 1,155 9. Flared or vented more than 1 hour (see instr.) 10,937 10. Pilot and Purge 36,849 11. Used tor base operations (specify In Remarks) 931,757 12. Outer (ties instruniaa) 0 s •__,.,� .. ..01 /11•0011 .t, - sr.S:tri k>15- ;;....�- authorization >1 hr Safety 10 MCF 13. TOTAL VOLUME (ITEMS 6 980,698 Lease We MCF 14. NGL Gas Equivalent 0 Conservation MCF 15. Purchased gas 0 Waste. MCF 18. Transferred Fran: CGF 955,101 ,1 4 -4. -07 � I mieetorler Dab 17. Transferred to: (Express as a negative t) CGF - 30,882,794 18. Remarks: Block 1 I: Fuel Gas = 918.252 mscf and Assist Gas = 13.505 mscf 1 hereby certify that Me foregoing is true and Correct o '. - best of my knowledge. //�� Art_ Phone Tale Manager, Production Taxes and Royalty Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. Signattxe ay Printed Name Bernard W. Hajny (907)564 -5028 Dade ?' �P�) Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate 'Unplanned Events less than or equal to 1 hour 1 DATE 2/9/2007 2/10/2007 2/10/2007 2/13/2007 2/13/2007 2/13/2007 2/18/2007 'Unplanned Events greater than 1 hour 1 DATE TIME 2/9/2007 1800-2359 2/10/2007 0001 - 1200 2/10/2007 1200 -2359 TOTAL DATE 2/3/2007 2/13/2007 2/13/2007 2/13/2007 2/15/2007 2/15/2007 DATE 2/1/2007 2/12/2007 2/15/2007 TIME 0845 -0851 1347 -1354 1539 -1540 1110-1145 1230-1235 1235 -1325 1335 -1352 TOTAL TIME 1515 -1612 1155 -1200 1730 -1735 2135 -2140 1210 -1243 1345 -1350 TOTAL TIME 1145 -2350 0850 -2000 0425 -0920 TOTAL VOLUME DESCRIPTION OF INCIDENT 8 CAUSE 372 Not required for unplanned events which 11 are less than or equal to 1 hour 2 3 3 340 108 839 VOLUME DESCRIPTION OF INCIDENT 8 CAUSE -,,, 266 See attachments 533 267 1,066 316 9,871 _.., = t TOTAL Unplanned Events c 1 Hour 839 Unplanned Events > 1 Hour 1,066 Planned Events < 1 tour and not 316 exceeding 5,000 MCF Planned Events > 1 hour or 9.671 exceeding 5,000 MCF Pilot Purps SUMP 38,841 Assist 13,606 TOTAL FLARED VOLUME 62.446 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-3 GAS FLARING INCIDENT REPORT February 2007 VOLUME DESCRIPTION OF INCIDENT Si CAUSE See attachments 3 3 3 158 3 VOLUME DESCRIPTION OF INCIDENT 8 CAUSE__, 5,006 See attachments 4,188 677 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are Tess than or equal to 1 how ACTION TAKEN TO ELIMINATE CAUSE See attachments `Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf 1 ACTION TAKEN TO ELIMINATE CAUSE, „ See attachments 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 1 ACTION TAKEN TO ELIMINATE CAUSE„,,,.,„,,, „ „., See attachments Fogel 39512007 3:30 PM Flare Start Date 2/1/2007 Flare End Date 2/28/2007 Report Date Time Of Flaring Start Time Stop Time 07 -50 Flare Relief 2/1/2007 11:45:00 AM 11:50:00 PM 725 minutes No Determination Cause STV -IP T\C 1802 shutdown due to valve leakage for blinding off work to repair STV -IP BC 1801. Action Taken 07-52 Controlled 2/3/2007 3:15:00 PM 4:12:00 PM 57 minutes Slowdown FS3 Flare Report Duration Intermittent Black Smoke Planned Reported By Blinding work completed and restarted STV -IP TT 1802. No No No Vas BP1\FINNOFPH Determination Cause Depressuring 8-HP separator to flare for work on L14 level control valve. Action Taken B -HP separator depresured and secured. 07 -58 Flare Relief 2/9/2007 600'00 PM 11:59:00 PM 359 minutes Determination Cause Action Taken 07 Flare Relief 2/10/2007 12:01:00 AM 12:00:00 PM 719 minutes No Determination Cause Action Taken Yes BP1 \FINNOFPH No No No BP1\FAINDT P337ASV/BSV found to be leaking' to flare due to suspected internal seat damage horn previous activation. Confirmed to be source of flare event by isolation of upstream dock valve. Returned PSV to service. Maintenance workorder submitted tor repair. No No BP1\FAINDT P337ASV/BSV leaking' to flare due to suspected internal seat damage from previous activation. Confirmed previously to be source of flare event by isolation of upstream block valves. Maintenance workorder was submitted for repair. P3376SV was removed from service in attempt to make necessary repairs. Volume (MSCF) 5006 146 268 533 Flare Start Date 2/1/2007 Flare End Date 2/28/2007 Report 07 Flare Relief 2/10 /2007 12:00:00 PM 11:59:00 PM 719 minutes No 07.85 Other 07 -66 Flare Relief 07 -66 Flare Relief 07 -66 Other Date Time Of Flaring Start Time Stop Time Determination Cause P337ASV continued leaking' to flare due to suspected internal seat damage from previous activation. The sister P3378SV was taken out of service to make necessary repairs. Action Taken 2/12/2007 8:50:00 AM 800:00 PM 670 minutes Determination Cause Action Taken FS3 Flare Report Duration Intermittent Black Smoke Planned Reported By Confirmed previously to be source of flare event. Maintenance workorder previously submitted. Awaiting repair and return of sister P337BSV. At that time, P337ASV will be taken out of service for necessary repairs. No No 2/13/2007 11:55:00 AM 12:00:00 PM 5 minutes No No Determination Cause Normal Shutdown of T/C 1802. Action Taken Normal blowdown after shutdown. 2/13/2007 5:30:00 PM 5:35:00 PM 5 minutes No No Determination Cause Normal shutdown for T/C 1802. Action Taken Normal blowdown after shutdown. No No BP/\FAINDT 1802 T/C shutdown and Process Gas vented to Flare to enable removal of Maintenance Blinds on 1801 T /C. Successfully vented enough gas to enable the removal of 1801 T/C Maintenance Blinds. Once Blinds were removed, 1802 T/C was brought back online (B.O.L.) Yes BPI \CARVERWJ Yes BP1\FAINDT Ves BP1\FAINDT 2/13/2007 935 PM 9:40:00 PM 5 minutes No No Ves BP1\FAINDT Determination Cause 1801 T/C Normal shutdown case depressuring volume. 1802 T/C had previously been brought online (B.O.LJ Action Taken 1801 T/C Normal shutdown case depressuring. Volume (MSCF) 267 4188 3 3 3 Flare Start Date 2/1/2007 Flare End Date 2/28/2007 FS3 Flare Report Time 01 Flaring Report Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume (MSCF) 07-58 Controlled 2/15/2007 425:00 AM 920:00 AM 295 minutes No No Yes 13P1\FAINOT 677 Blowdown Determination Cause 6C/1 38 conrnanline was depressured for ESO valve repair at D56. Action Taken Reached minimal pressure and blocked valve to flare. 07-68 Controlled 2/15/2007 12:10:00 PM 12:43:00 PM 33 minutes No No Yes BP1\FAINDT 158 Blowdown Determination Cause 6D cormanhine was depressured for ESD valve repair. Action Taken Reached minimum pressure and docked valve to flare. 07 -68 Flare Relief 2/15/2007 1:4500 PM 1:50:00 PM 5 minutes No No Yes BP i\FAINDT Determination Cause T/C 1802 normal shutdown after TIC 1801 was brought on line and loaded. Action Taken Normal blowdown after shutdown. 3 GPB Gas Flaring Incident Subject: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com> Date: Fri, 02 Feb 2007 12:50:40 -0900 To: steve_mcmains@admin.state.ak.us To: Steve McMains, AOGCC steve_mcmains @admin.state.ak. us 907 - 793 -1241, fax 907-276-7542 CC: "GPB, Environ TL" <GPBEnvironTL @BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast@BP.com >, "Fiedler, Anne M" <Anne.Fiedler@bp.com >, "Benson, Gary A" <Gary.Benson @bp.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer @bp.com >, "Kurz, John" <john.lcurz @bp.com >, "GPB, FS3 OTL" <GPBFS3OTL@bp.com >, "GPB, Area Mgr Central (GC1 /3/ FS3 ) "$GPBAreaMgrCeihtral@BP.coin>. From: Hal Tucker, GPB Prod Optimization Team Leader An extended flaring event occurred on February 1, 2007. In order achieve adequate isolation to install blinds on the FS3 1801 STV /IP machine, the 1802 machine had to be shut down. Prior to shutting down 1802, the isolation valves were greased and stroked in an attempt to complete the blinding operation without shutting down 1802. The blinding work was being done in preparation for installation of upgraded (higher temperature) O -rings in both 1801 and 1802. Installation of these O -rings will allow the machines to run at higher discharge temperatures. Flaring occurred from 1145 hrs to 2350 hrs (725 minutes), total volume flared was 5006 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659 -4472 ' 1 of 1 2/2/2007 1:03 PM Fadety Number 0290000030 2. Facility Name PBU FS 3 3. Field PBU - EOA 14. 4. Operator 5. MontlVYesr at Disposition March -2007 Disposition Volume MCF l _ 20 For production from multiple pools. list contribution of each pool as a percent of Total Volume 8. Soot 0 Pool Name Pool Code Percent 7 Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or teas 382 9. Flared or vented more Man 1 hour (see inst.) 10,292 10. Psot and Purge 40,910 11. Used for lease operations (specify In Remarks) 1,050,676 12. Other (see instructions) 0 f1 ,'..•z- e..),lN OnfYi °e`er` -_ -; s -- "?? Authorization >1 hr. Safety / � h ' /+ z c� L `? MCF 13. TOTAL VOLUME (ITEMS 6-12) 1 ,102,260 Lease Use MCF 14. NOL Gas Equivalent 0 Conservation MCF 15. Purchased gas 0 Waste: MCF 18. Transferred from: CGF 1,075,903 ''7 is ` Deb / 17. Transferred to: (Express as a negative 1) CGF - 33,445,945 18. Remarks: Block 11: Fuel Gas = 1,034,943 mutt and Assist Gas = 15.683 mscf I hereby certify that the for omg is true corn c the best of my knowledge. Signature Title Manager, Production Taxes and Royalty Note: All volumes must be corrected to pressure of 14.65 psta and to a temperature of 60o P. Authority 20 AAC25.235. Printed Name Bernard W. Hajny Phone (907)564 -5028 Date Y _/� -07 • Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate 0 `Unplanned Events less than or equal to 1 hour 1 DATE TIME 3/11/2007 1344 -1400 3/28/2007 0200 - 0240 TOTAL 1 (Unplanned Events greater than 1 hour VOLUME DESCRIPTION OF INCIDENT & CAUSE 559 See attachments DATE TIME 3/19/2007 1322 -1445 TOTAL. 346 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS - 3 GAS FLARING INCIDENT REPORT March 2007 VOLUME DESCRIPTION OF INCIDENT & CAUSE 95 Not required for unplanned events which 251 are less than or equal to 1 hour 559 1 !Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf VOLUME DESCRIPTION OF INCIDENT & CAUSE 3 See attachments 3 DATE 3/10/2007 3/10/2007 3/19/2007 3/19/2007 3/20/2007 3/20/2007 3/21 /2007 3/21 /2007 TIME 1550 -1555 1710 -1715 1937 -1942 2100 -2105 1525 -1530 1600 -1605 1032-1130 1645 -1650 TOTAL 3 3 3 3 15 3 38 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments (Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 1 DATE TIME 3/18 -19/07 0300 -0145 3/24/2007 0945 -1610 TOTAL Unplanned Events c 1 Hour Unplanned Events> 1 Hour Planned Events e 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5000 MCF Pilot Purge Assist TOTAL FLARED VOLUME VOLUME DESCRIPTION OF INCIDENT & CAUSE 7,583 See attachments 2,150 9,733 TOTAL 346 559 36 9.733 P*4(Xgra 40,910 15,683 67,267 ACTION TAKEN TO ELIMINATE CAUSE See attachments Pepe 1 4/!12007 9.41 AM Flare Start Date 3/1/2007 Flare End Date 3/31/2007 Report Number 07 -86 Flare Relief 07 -94 Flare Relief 07-95 Flare Relief Date Time Of Flaring Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By 07.86 Flare Relief 3/10/2007 3:50:00 PM 3:55:00 PM 5 minutes No No Determination Cause TIC 1801 normal stop after starling and loading T/C 1802. Action Taken T/C 1801 normal blowdown after shutdown. 3/10/2007 5:10:00 PM 5:15:00 PM 5 minutes No No Determination Cause T/C 1802 normal stop after starting and loading T/C 1801. Action Taken TIC 1802 normal blowdown after shutdown. 3/18/2007 3:00:00 AM 12:00:00 AM 1260 minutes No Action Taken 3/19/2007 12:00:00 AM 1:45:00 AM 105 minutes No Determination Cause Action Taken 07 - 95 Flare Relief 3/19/2007 122 PM 2:45:00 PM 83 minutes Determination Cause Action Taken FS3 Flare Report No Ves Determination Cause T 1801 shutdown for planned maintenance to blind 1802 for Overhaul work. 1801 failed to restart and declared Out of Service. Initiated removal of blinds on 1802 to put back in service to stop flaring IP and STV gas. No No No 1802 T/C brought back online. Increased NGL divert to increase gas mole weight Corrected STV Compressor Discharge Valve malfunction. Yes BP1 \FAINDT Ves BP1\FAINDT BPi \HARDINS No Ves BP1 \CARVERWJ Continuation of 03 -18-0Ts T/C 1801 Shutdown for planned maintenance to blind 1802 for overhaul work. 1801 failed to restart and declared out of Service (00S) Completed removal of Binds on T/C 1802 and put back in service to stop flaring IP and STV gas. 1802 T/C shutdown on IP Compressor High Discharge Temperature. BP1 \CARVERWJ Volume (MSCF) 3 3 7000 583 559 Flare Start Date 3/1/2007 Flare End Date 3/31/2007 Action Taken FS3 Flare Report Time Of Flaring Report Number Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume (MSCF) 07 -95 Flare Relief 3/19 /2007 7:37:00 PM 7:4200 PM 5 minutes No No Yes BPI\CARVERWJ 3 Determination Cause STV -IP INC 1801 manually shutdown due to speed controller problems Action Taken Normal blowdown after shutdown. 07 -95 Flare Relief 3/19/2007 9:00:00 PM 9 PM 5 minutes No No Yes BPI \CARVERWJ 3 Determination Cause STV-IP T\C 1801 manually shutdown to trouble shoot speed controller problems Action Taken Normal blowdown after shutdown 07 -99 Flare Relief 3/20/2007 3:25:00 PM 3:30:00 PM 5 minutes No No Yes 8P1\HARDINS 3 Determination Cause STV -IP T\C 1801 shutdown due to a problem with speed controller. Action Taken Normal blowdown after shutdown 07 -99 Flare Relief 3/20/2007 4:00:00 PM 4:05:00 PM 5 minutes No No Yes BP1 \HARDINS 3 Determination Cause STV -IP T\C 1801 shutdown due to a problem with speed controller. Action Taken Nominal blowdown on Shutdown. 07 - 100 Flare Relief 3/21/2007 10:32:00 AM 11:30:00 AM 58 minutes Yes No Yes BPI \MEAD.IW 15 Determination Cause 1801 T/C 3 START ATTEMPTS, DEPRESSURINGS AND COMPERSSOR PURGE CYCLES. DEPRESSURING AND PURGING COMPLETED AND MACHINE BROUGHT ON -LINE Flare Start Date 3/1/2007 Flare End Date 3/31/2007 Report Number Action Taken FS3 Flare Report Time Of Flaring Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume (MSCF) 07 -100 Flare Relief 3/21 /2007 4:45:00 PM 4:50:00 PM 5 minutes No No Yes BP1 \MEADJW 3 Determination Cause 1802 T/C SHUTDONW AND SECURED AFTER 1801 T/C BROUGHT ON -LINE Action Taken SHUTDOWN AND DEPRESSURING COMPLETED AND MACHINE SECURED. 07 -102 Flare Relief 3/24/2007 9:45:00 AM 4:10:00 PM 385 minutes No No Yes BP1 \MEADJW Determination Cause 1801 T/C Shutdown and restart. Volumes from 2 purge cycles and 2 Shutdown depressunngs. Action Taken 1801 purging and depressudng competed and secured. 07 -102 Flare Relief 3/24/2007 9:45:00 AM 4:10:00 PM 385 minutes . No No Yes 8P1 \MEADJW 2138 Determination Cause T\C 1801 shutdown for planned maintenance and Winding on 1802 compress. T/C 1801 Restarted, flaring stopped. 12 FS3 Flaring Event 3/18-3/19 Subject: FS3 Flaring Event 3/18 -3/19 From: "GPB, Optimization Engr" <GPBOptimizationEngr @BP.com> Date: Mon, 19 Mar 2007 22:33:37 -0800 To: steve_mcmains @admin.state.ak.us CC: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com >, "GPB, Environ TL" <GPBEnvironTL @BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast @BP.com >, "GPB, Environ Advisor West" <GPBEnvironAdvisorWest @BP.com>, "Fiedler, Anne M" <Anne.Fiedler @bp.com >, "Benson, Gary A" <Gary.Benson @bp.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer @bp.com >, "GPB, GC2 OTL" <gpbec2otl @BP.com >, "Kurz, John" <john.kurz@bp.com >, "GPB, Area Mgr Central (GC1 /3!FS3)" <GPBAreaMgrCentral@BP.com >, "GPB, FS3 MTL" <GPBFS3MTL @bp.com >, "GPB, FS3 OTL" <GPBFS3OTL @bp.com >, "GPB, FS3 /GC3 Proc Eng " <GPBFS3GC3ProcEn 'll" ecpj:iW s:cf2,rri?ai1Cvwube'.' To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907 - 276 -7542 From: Beverly Luedke -Chan for Hal Tucker, Prod Optimization Team Leader An extended flaring event occurred at F53 on March 18 and 19. The 1801 compressor was shutdown to isolate 1802 for maintenance but failed to restart after 1802 was isolated. Several attempts were made to bring on 1801 until a front bearing was found to be bad. The 1802 compressor was then "unblinded" and put back in service. The TAPS pro- ration was lifted at 07:15 hours on 3/18/07. We elected to maintain the reduced rates until the 1801 IP compressor was on -line to minimize additional flaring. As a result, F53 started increasing production once 1802 IP compressor was on -line at 01:45 hours on 3/19/07. Flaring occurred from 03:00 to midnight on 3/18 and from midnight to 01:45 on 3/19 (22hr, 45 minutes total) and the volume was 7,000 MSCF. If you require additional information, please don't hesitate to call me. Beverly Luedke -Chan, Field Optimization Engineer For Hal Tucker, Prod Optimization Team Leader BP Exploration Ak, Inc (907) 659 -5566 (Hal) (907) 659 -4382 (Beverly) 1 of 1 3/25.2007 2:24 PM FS3 Flaring Event 3/19 Subject: FS3 Flaring Event 3/19 From: "GPB, Optimization Engr" <GPBOptimizationEngr @BP.com> Date: Mon, 19 Mar 2007 22:37:20 -0800 To: steve_mcmains @admin.state.ak.us CC: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com >, "GPB, Environ TL" <GPBEnvironTL @BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast @BP.com >, ?, "GPB, Environ Advisor West" <GPBEnvironAdvisorWest @BP.com >, "Fiedler, Anne M" <Anne.Fiedler @bp.com >, "Benson, Gary A" <Gary.Benson @bp.com >, "Pfeiffer, Jim A" <Jim.PfeifTer @bp.com >, "Kurz, John" <john.kurz @bp.com >, "GPB, Area Mgr Central (GC1 /3/FS3)" <GPBAreaMgrCentral @BP.com >, "GPB, FS3 MTL" <GPBFS3MTL @bp.com >, "GPB, FS3 OTL" <GPBFS3OTL@bp.com >, "GPB, FS3 /GC3 Proc Engr" <GPBFS3GC3ProcEngr @BP.com> . To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907 - 276 -7542 From: Beverly Luedke -Chan for Hal Tucker, Prod Optimization Team Leader An extended flaring event occurred at F53 on March 19. The 1802 compressor shutdown on IP Compressor High Discharge Temperature. 1802 was brought back online. Furthermore, we increased NGL divert to increase gas mole weight which brought the temperature back down:'. . Flaring occurred from 1:22 pm to 2:45 pm on 3/19 (1 hr 23 minutes) and the volume was 0.559. • MSCF. If you require additional information, please don't hesitate to call me. Beverly Luedke -Chan, Field Optimization Engineer For Hal Tucker, Prod Optimization Team Leader BP Exploration Ak, Inc (907) 659 -5566 (Hal) (907) 659 -4382 (Beverly) I of I 3/25/2007 2:24 PM REVISED: FS3 Flaring Event 3/18 -3/19 Subject: REVISED: FS3 Flaring Event 3/18 -3/19 From: "GPB, Optimization Engr" <GPBOptimizationEngr @BP.com> Date: Tue, 20 Mar 2007 13:48:09 -0800 To: "GPB, Optimization Engr" < GPBOptimizationEng@BP.com>, steve_mcmains @admin.state.ak.us CC: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com >, "GPB, Environ TL" <GPBEnvironTL@BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast@BP.com>, "GPB, Environ Advisor West" <GPBEnvironAdvisorWest @BP.com >, "Fiedler, Anne M" <Anne.Fiedler @bp.com >, "Benson, Gary A" <Gary.Benson @bp.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer @bp.com >, "Kurz, John" <john.kurz @bp.com >, "GPB, Area Mgr Central (GC1/3/FS3) " <GPBAreaMgrCentral @BP.com >, "GPB, FS3 MTL" <GPBFS3MTL @bp.com >, "GPB, FS3 OTL" <GPBFS3OTL@bp.com >, "GPB, FS3 /GC3 Proc Engr ". <GPBFS3GC3ProcEngr @BP.com> My apologies. The total flare volume for this event was 7583 MSCF, not 7000 MSCF as stated below. The volume was 7000 MSCF on March 18 and an additional 0.583 MSCF on March 19. The event lasted from 03:00 on March 18 to 01:45 on March 19 as originally stated. To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us ' 907 - 793 -1241, fax 907 - 276 -7542 From: Beverly Luedke -Chan for Hal Tucker, Prod Optimization Team Leader An extended flaring event occurred at F53 on March 18 and 19. The 1801 compressor was shutdown to isolate 1802 for maintenance but failed to restart after 1802 was isolated. Several attempts were made to bring on 1801 until a front bearing was found to be bad. The 1802 compressor was then "unblinded" and put back in service. The TAPS pro- ration was lifted at 07:15 hours on 3/18/07. We elected to maintain the reduced rates until the 1801 IP compressor was on -line to minimize additional flaring. As a result, F53 started increasing production once 1802 IP compressor was on -line at 01:45 hours on 3/19/07. Flaring occurred from 03:00 to midnight on 3/18 and from midnight to 01:45 on 3/19 (22hr, 45 minutes total) and the volume was-7- 7,583MSCF. If you require additional information, please don't hesitate to call me. Beverly Luedke -Chan, Field Optimization Engineer For Hal Tucker, Prod Optimization Team Leader BP Exploration Ak, Inc (907) 659 -5566 (Hal) (907) 659 -4382 (Beverly) 1 of 1 3/25/2007 2:28 PM FW: GPB Gas Flaring incident Subject: FW: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com> Date: Tue, 27 Mar 2007 07:49:44 -0800 To steve_mcmains@admin.state.ak.us Didn't go through the first time. Hal From: GPB, Prod Opt TL Sent: Tuesday, March 27, 2007 7:33 AM To: " steve _mcmains @admin.state.ak.us' Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, F53 OTL; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, GC1 011L; GPB, Environ Advisor West Subject: GPB Gas Flaring Incident To: Steve McMains, AOGCC steve_mc ma i ns @ad mi n. state. ak. us 907 - 793 -1241, fax 907 - 276 -7542 Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 From: Hal Tucker, GPB Prod Optimization Team Leader Two extended flaring events occurred last week at Greater Prudhoe Bay. The first event occurred at FS3 on March 24. In order achieve adequate isolation to install blinds on the FS3 1802 STV /IP machine, the 1801 machine had to be shut down. The blinding work was being done in preparation for installation of upgraded (higher temperature) O -rings in 1802. Installation of these O -rings will allow 1802 to run at higher discharge temperatures, ensuring fully spared STV /IP capacity at FS3 (upgraded O -rings were successfully installed in 1801 last month). Flaring occurred from 0945 hrs to 1610 hrs (385 minutes), total volume flared was 2150 MSCF. The second event occurred at GC1 on March 26 at 1430. In preparation for the upcoming GC1 automation upgrade, PCM (Process Control Module) work was being done that resulted in set points changing from auto to manual. Intermittent flaring occurred for 100 minutes during that work resulting in a flared volume of 69 MSCF. If you require additional information, please don't hesitate to call me. I of I 3/27/2007 8:17 AM FW: GPB Gas Flaring Incident Subject: FW: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com> Date: Tue, 03 Apr 2007 07:39:40 -0800 To: steve_mcmains @admin.state.ak.us CC: "GPB, Environ TL" <GPBEnvironTL@BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast @BP.com >, "Fiedler, Anne M" <Anne.Fiedler @BP.com >, "Benson, Gary A" <Gary.Benson@BP.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer@BP.com >, "Kurz, John" <john.kurz @BP.com>, "GPB, FS3 OTL" <GPBFS3OTL @BP.com >, "GPB, Area Mgr Central (GC1 /3/FS3)" <GPBAreaMgrCentral @BP.com >, "GPB, Optimization Engr" <GPBOptirnizationEngr@BP.com Subject: GPB Gas Flaring Incident To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907 - 276 -7542 From: Hal Tucker, GPB Prod Optimization Team Leader An extended flaring event occurred on April 2 at Greater Prudhoe Bay. The event occurred at FS3 when 1801 STV /IP machine was shut down to remove blinds following the 1802 upgrade (see email below). Three restart attempts were required to bring 1801 back on line. Flaring occurred from 1330 to 1500 (90 minutes), total volume flared was 700 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 From: GPB, Prod Opt TL Sent: Tuesday, March 27, 2007 7:33 AM To: " sieve _mcmains @admin.state.ak.us' Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, FS3 OTL; GPB, Area Mgr Central (GC1 /3/F53); GPB, GC1 OTL; GPB, Environ Advisor West To: Steve McMains, AOGCC steve_mcm a i ns@ ad mi n. state. ak, us 907- 793 -1241, fax 907 - 276 -7542 From: Hal Tucker, GPB Prod Optimization Team Leader Two extended flaring events occurred last week at Greater Prudhoe Bay. The first event occurred at FS3 on March 24. In order achieve adequate isolation to install blinds on the FS3 1802 STV /IP machine, the 1801 machine I ul 1 2110 17 \�.� FW: GPB Gas Flaring Incident had to be shut down. The blinding work was being done in preparation for installation of upgraded (higher temperature) O -rings in 1802. Installation of these O -rings will allow 1802 to run at higher discharge temperatures, ensuring fully spared STV /IP capacity at FS3 (upgraded O -rings were successfully installed in 1901 last month). Flaring occurred from 0945 hrs to 1610 hrs (385 minutes), total volume flared was 2150 MSCF. The second event occurred at GC1 on March 26 at 1430. In preparation for the upcoming GC1 automation upgrade, PCM (Process Control Module) work was being done that resulted in set points changing from auto to manual. Intermittent flaring occurred for 100 minutes during that work resulting in a flared volume of 69 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659 -4472 ni ' 4 ; 2007 8 - 1 :.4M 1 Faosty Number 0290000030 2 Facility Name PBU FS 3 3. Field PBU - EOA 4 Operator BP 5. MontWYear of Deposition April - 2007 Disposition Volume MCF 20. For production from multiple pods, list contribution 04 each pool as a percent of total Volume t Sold 0 Pod Name Pod Code Percent 7. Reinteaeo O PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 2,246 1 nnur (see Instr.) 2,149 9. Flared or vented more than 10. Plot and Rage 34,154 f 11. Used for lease operations (specify in Remarks) 979,955 i. `} `n'F6: -^ �; .- '�~" �'dv 12. Qatar (see kl$tnlLnnna) 0 i.A.rt •�: ••r t Authorization >1 hr. Safety 2r /dig MCF 13. TOTAL VOLUME (ITEMS 6-12) 1,018,504 Lease Use MCF 14. NOL Gas Equivalent 0 Conservation MCF 15. Psdiased gas O Waste. MCF 16. Transferred from- CGF 999,075 -/..3 -0 7 ali U misabner Date 17. Transferred to: (Express as a negative it) CGF - 32,661,575 18. Remarks. Block 11: Fuel Gas = 965,25S nscf and Assist Gas = 14,697 mscf I hereby certify that the for rig is true anti correct to the best of my kaledge. Signature Tide Manager, Production Taxes and Royalty Note: All volumes must be corrected to pressure of 14.65 psla and to a temperature of 60o F. Authority 20AAC25.235- Printed Name Bernard W. Hajny Phone (907)564 -5028 Date J —1.1 Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate 2,225 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT April 2007 1 (Unplanned Events Tess than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 4/2/2007 2220 -2245 15 Not required for unplanned events which 4/3/2007 0001 -0010 12 are less than or equal to 1 hour 4/3/2007 1030 -1100 9 4/4/2007 0230 -0252 144 4/6/2007 1918 -1930 1,167 4/14/2007 1240 -1245 3 4/14/2007 1255 -1300 3 4/18/2007 1743-1755 331 4/19/2007 2012 -2027 12 4/20/2007 1127 -1142 4 4/23/2007 2220 -2240 511 4/24/2007 1055 -1112 11 4/30/2007 0940 -0946 1 4/30/2007 1720 -1726 1 4/30/2007 1817 -1823 1 TOTAL ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour 1 (Unplanned Events greater than 1 hour TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE DATE 4/2/2007 1330 -1500 TOTAL 670 See attachments 670 !Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 4/3/2007 1615 -1620 3 See attachments 4/4/2007 1300 -1305 3 4/10/2007 0948 -0953 3 4/14/2007 1200 -1205 3 4/14/2007 1545-1550 3 4/14/2007 1645 -1650 3 4/15/2007 1015 -1020 3 TOTAL 21 ACTION TAKEN TO ELIMINATE CAUSE See attachments 1 ACTION TAKEN TO ELIMINATE CAUSE See attachments Page 1 5/8/2007 10:49 AM I Ptanned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 1 DATE 4/2/2007 4/4/2007 4/10/2007 TIME 1330 -1500 1250-1450 0950 -1140 TOTAL VOLUME DESCRIPTION OF INCIDENT & CAUSE 15 See attachments 750 714 1,479 TOTAL Unplanned Events < 1 Hour 2,225 Unplanned Events> 1 Hour 670 Planned Events < 1 hour and not 21 exceeding 5,000 MCF Planned Events > 1 hour or 1,479 exceeding 5,000 MCF Pilot Purge _ _ 34,154 Assist i 1'x1. 14.697 TOTAL FLARED VOLUME 53 246 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-3 GAS FLARING INCIDENT REPORT April 2007 ACTION TAKEN TO ELIMINATE CAUSE See attachments Page 2 5/6/2007 10:49 AM Flare Start Date 4/1/2007 Flare End Date 4/30/2007 Action Taken FS3 Flare Report . Time 01 Flaring Report Number Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume (MSCF) 07 - 117 Flare Relief 4/2/2007 1:30:00 PM 3:00:00 PM 90 minutes No No Yes BP1 \MFADJW 15 Determination Cause 1901 T/C shutdown due to blind removal on 1802 T/C had 2 failed start attempts and 3 compressor purges during retart Action Taken 1801 T/C started and brought on-line and flaring stopped. 07 -117 Flare Relief 4/2/2007 1:30:00 PM 3:00:00 PM 90 minutes No No No BPI \MEADJW 670 • Determination Cause 1801 T/C Shutdown for blind removal on 1802 T /C. Action Taken Work completed and machine brought online. 07-119 Flare Relief 4/3/2007 4:15:00 PM 42000 PM 5 minutes No No Yes BPI \MEADJW 3 Determination Cause 1801 T/C SHUTDOWN FOR SCHEDULES MAINTENANCE, COMPRESSOR DEPRESSURED TO FLARE. Action Taken 1801 T/C DEPRESSURING COMPLETED AND SECURED, 07 -120 Flare Relief 4/4/2007 12:50:00 PM 2:50:00 PM 120 minutes No No Yes BP1 \MEADJW 750 Determination Cause 1802 STV / IP compressor was shut down to Depressure and un- couple the Compressor and Power Turbine on 1801 for overhaul crew work Energy isolation on 1801 was competed and 1802 was restarted and brought back an line. 07 -120 Flare Relief 4/4/2007 1:00:00 PM 1:06:00 PM 5 minutes No No Yes 13P14v1EADJW 3 Determination Cause STV - TC 1802 shutdown to Depressure and uncouple 1801 for Overhaul work Action Taken Normal Blowdown after shutdown. 07-135 Flare Relief 4/10/2007 9:48:00 AM 9:5310 AM 5 minutes No No Yes BP1nHARDINS Determination Cause STV -IP T\C 1802 shutdown to depressure and re the 1801 Compressor after the PT overhaul. Action Taken Normal Slowdown after shutdown. 3 Flare Start Date 4/1/2007 Flare End Date 4/30/2007 Report Number Date 07 -135 Flare Relief 4/10/2007 07 -142 Other 4/14/2007 07 -142 Other 4/14/2007 07 -142 Other 07 -144 Other 4/14/2007 4:45:00 PM Time Of Flaring Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By 9:50:00 AM Determination Cause SN -IP INC 1802 shutdown to depressure and recouple the 1801 Compressor after the PT overhaul. Action Taken 12:00:00 PM Determination Cause 1801 T/C Shutdown Crank Mode after Pre -Lube cycle post maintenance. Action Taken 1801 T/C Normal manually initiated shutdown. 3:45:00 PM 3:50:00 PM 5 minutes No Determination Cause 1801 T/C normal shutdown post Turbine Waterwash. Action Taken Determination Cause Action Taken 4/15/2007 10:15:00 AM 10:20:00 Determination Cause Action Taken FS3 Flare Report 11:40:00 AM 110 minutes No Energy Isolation on 1801 was completed and 1802 was restarted and brought back online to get off of flare. 12:05:00 PM 5 minutes No 4:50:00 PM 5 minutes No NO No Yes BPIWARDINS NO Yes 1801 T/C normal case depressuring upon initiated shutdown. 1801 T/C Normal shutdown from idle speed post maintenance troubleshooting Ot vibration problems. 1801 T/C normal case depressuring upon initiated shutdown. 8P11CARVERWJ No Yes BP1CARVERWJ Yes BPf\CARVERWJ AM 5 minutes No No Yes 8P1 \HARDINS STV -IP INC 1801 shutdown tram ale speed after trouble shooting vibration problems. STV -IP T\C 1801 normal case depressure after initiated shut down. Volume (MSCF) 714 3 3 3 3 FW: GPB Gas Flaring Incident Subject: FW: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com> Date: Tue, 03 Apr 2007 07:39:40 -0800 To: steve_mcmains@admin.state.ak.us CC: " GPB, Environ TL" <GPBEmrironTL@BP.com>, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast@BP .corn >, "Fiedler, Anne M" <Anne.Fiedler@BP.com >,'Benson, Gary A" <Gary.Benson@BP.com>, "Pfeiffer, Jiro A" <Tim.Pfeif)fbr%BP.com >; "Kurz, John" '' <john.kurz@BP.com >, "GPB, FS3 OTL" <GPBFS3OTLQBP.corn >, "GPB, Area Mgr Centrat t> (GC1/3/FS3)" <GPBAreaMgtCentral @+: P.com >, "GPB, Optiinizatibn Fate <GPBOptimizl tionEngr@BP.coun> Staittr t. Subject: GPB Gas Flaring Incident To Steve McMains. AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907 - 276 -7542 From Hal Tucker. GPB Prod Optimization Team Leader An extended flaring event occurred on April 2 at Greater Prudhoe Bay. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 The event occurred at FS3 when 1801 STV /IP machine was shut down to remove blinds following the 1802 upgrade (see email below). Three restart attempts were required to bring 1801 back on line. Flaring occurred from 1330 to 1500 (90 minutes), total volume flared was 700 MSCF. From: GPB, Prod Opt TL Sent: Tuesday, March 27, 2007 7:33 AM To: " steve _mcmains @admin.state.ak.us' Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, F53 OIL; GPB, Area Mgr Central (GC1 /3/F53); GPB, GC1 OTL; GPB, Environ Advisor West To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907- 276 -7542 From Hal Tucker, GPB Prod Optimization Team Leader Two extended flaring events occurred last week at Greater Prudhoe Bay. The first event occurred at FS3 on March 24. In order achieve adequate isolation to install blinds on the FS3 1802 STV /IP machine, the 1801 machine I of 2 4 3 '200 S.I 7 AM FW: GPB Gas Flaring Incident had to be shut down. The blinding work was being done in preparation for installation of upgraded (higher temperature) 0 -rings in 1802. Installation of these O -rings will allow 1802 to run at higher discharge temperatures, ensuring fully spared STV /IP capacity at FS3 (upgraded O -rings were successfully installed in 1801 last month). Flaring occurred from 0945 hrs to 1610 hrs (385 minutes), total volume flared was 2150 MSCF. The second event occurred at GC1 on March 26 at 1430. In preparation for the upcoming GC1 automation upgrade, PCM (Process Control Module) work was being done that resulted in set points changing from auto to manual. Intermittent flaring occurred for 100 minutes during that work resulting in a flared volume of 69 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659 -4472 of 4'32007 8 :13 AM RE: GPB Gas Flaring Incident Subject: RE: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com> Date: Thu, 05 Apr 2007 08:20:25 -0800 To: "GPB, Prod Opt TL" <GPBProdOptTL@BP.com >, steve_mcmains@admin.state.ak.us CC: "GPB, Environ TL" <GPBEnvironTL @BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast @BP.com >, "Fiedler, Anne M" <Anne.Fiedler@bp.com >, "Benson, Gary A" <Gary.Benson @bp.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer@bp.com >, "Kurz, John" <john.kurz @.hp com >, "GPB, FS3 OTL" <GPBFS3OTr,@ p c m >, "CPU, Area Mar C (GC1 /3/FS3)" <GPBAreaMgrCentral @BP.com >, "GPB, Optimization Engr <GPBOptimizationEngr@BP.com >" for To: Steve McMains, AOGCC steve mcmains @admin.state.ak.us 907 -793 -1241, fax 907 - 276 -7542 From: Dwight Warner, GPB Field Optimization Engineer for Hal Tucker, GPB Prod Optimization Team Leader An extended flaring event occurred on April 4 at Greater Prudhoe Bay. The event occurred at FS3 when 1802 STV /IP machine was shut down to depressurize and un- couple the compressor from the power turbine on 1801. Energy isolation on 1801 was completed and 1802 was restarted and brought back on line. Flaring occurred from 1250 to 1450 (120 minutes), total volume flared was 750 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner GPB Field Optimization Engineer (907) 659 -4382 Hal Tucker GPB Prod Optimization Team Leader (907) 659 -4472 I of I 4/5/2007 8:34 AM 1. Facility Numb Numb 0290000030 12. Fa FacilityFacilityName PBU FS 3 3 Field PBU - EOA d Operator IBP 5. Month/Year 04 Disposition Is. Disposition Volume MCF 20. For production from multiple pods, list contribution of each pool as percent of Total Volume 6 SoW 0 Pool Name P001 Cooe Percent 7 ply 0 PRUDHOE 640150 100.00% 9. Flared or vented 1 hour or less 3,144 9. Flared or vented more roan t hour (see Met.) 3,947 """ 10 Pilot and Purge 33,736 ✓ 11 . Used for lease operations (specify in Remarks) 962,222 12. Other (se*instructions) RECEI 0 Authorization >1 hr Safety / 31 Cj�f n MCF 13. TOTAL VOLUME (REMS 8-12) JUN 2 22007 1,003,049 Lease Use MCF 14. NGL Gas Equivalent 0 Conservation MCF ✓ OM $ Gent tAnN1M [ 1, 15. Purchased pas D Waste MCF 16. Transferred from CGF 978,179 /n / ( /�' � // 17. Transferred to: (Express as a negative a) CGF - 31,276,137 CorrhmKaionsr Date 18. Rentarke: Block 11: Fuel Gas = 944,443 mscf and Assist Gas = 17,779 nisei I hereby certify mat the foregoing is hue and correct to the best of my knowledge. 'G f .L _ Signature , \1 `�'w � tine Manager, Production Taxes and Royalty Note: All volumes must be corr corrected to pressure of 14.65 pals and to a temperature of 60o F. Authority 20 AAC25235. Printed Name Bernard W. Hajny Phone (907)564 -5028 Date Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSIT Submit in Duplicate 1 (Unplanned Events Tess than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 5/5/2007 0828 -0833 155 Not required for unplanned events which 5/9/2007 1911 -1916 3 are less than or equal to 1 hour 5/9/2007 1916 -2005 290 5/11/2007 1352 -1358 3 TOTAL 451 (Unplanned Events greater than 1 hour 1 DATE 5/5/2007 5/11/2007 TIME 1148 -1258 1140 -1350 TOTAL VOLUME DESCRIPTION OF INCIDENT & CAUSE 350 See attachments 941 1,291 OP EXPLORATION (ALASKA) INC. PRUDHOE SAY UNIT - FS -3 GAS FLARING INCIDENT REPORT May 2007 `Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 5/3/2007 0200 - 0230 442 See attachments 5/3/2007 0303 -0318 85 5/5/2007 1238 -1243 240 5/5/2007 0550 -0555 240 5/5/2007 1012 -1017 240 5/6/2007 1510 -1515 3 5/7/2007 1650 -1655 240 5/8/2007 1346 -1351 240 5/8/2007 1620 -1625 240 5/11/2007 0924 -0929 240 5/11/2007 1050 -1055 240 5/11/2007 1323 -1328 240 5/11/2007 1447 -1452 3 TOTAL 2,693 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments Page 1 1 6/13/2007 9:07 AM (Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 1 DATE 5/30/2007 1410 -2115 TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE. TOTAL TOTAL Unplanned Events < 1 Hour 451 Unplanned Events > 1 Hour 1,291 Planned Events < 1 hour and not 2,693 exceeding 5,000 MCF Planned Events > 1 hour or 2,656 exceeding 5,000 MCF Pilot Purge 33,736 Assist TOTAL FLARED VOLUME 2,656 See attachments 2,656 58,606 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - F5-3 GAS FLARING INCIDENT REPORT May 2007 ACTION TAKEN TO ELIMINATE CAUSE See attachments Page 2 6/13/2007 9:07 AM Flare Start Date 5/1/2007 Flare End Date 5/31/2007 Report Number Date System Time Of Flaring Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By 07-172 CM Bklwdown 5/3/2007 2:00:00 AM 2:30:00 AM 30 minutes No Determination Cause In preparation for planned maintenance on a flange on B HP's Gas Scrubber Liquid Pot Bridle line, the B HP train in 4908 was Blocked in, isolated and depressured to flare. This included the HP Oil Separator, Action Taken the Gas Scrubber and the Gas Scrubber Liquid pot. 07 -172 CM Blo down 5/3/2007 3:03:00 PM 3:18:00 PM 15 minutes No Determination Cause 'B' HP Separator, HP Gas Scrubber, and HP Gas Scrubber Liquid Pot • Vessels manually depressured to flare after "failed' leak test on Liquid Pot flange gasket replacement" Action Taken 07 -174 Ctrl Slowdown 5/5/2007 12:38:00 AM 12:4.3:00 AM 5 minutes No No Ves BPI HARDINS Determination Cause Normal case depressure of 1806 AL T\C system which was shutdown to cool down in preparation for OHC water wash. Action Taken 07 Ctrl Slowdown 5/5/2007 5:50:00 AM 5'55:00 AM Determination Cause Action Taken 07 Cm Slowdown 5/5/2007 10:12:00 AM 10:17:00 Determination Cause Action Taken 07 -174 Flare Relief 5/5/2007 11:48:00 AM Determination Cause Action Taken FS3 Flare Report Pressure bled to zero on vessels and flaring stopped. Completed vessel depressuring to enable additional investigation, evaluation and potential repairs (gasket replacement). Case depressured and flare ceased. 5 minutes No 1806 T/C Normal Compressor Case depressuring volume. 12 PM 70 minutes No No No 1801 T/C unexpectently shutdown down suspected high vibration /Instrumentation malfunction. No Yes BP1HARDINS No Yes BP 1HARDINS No Ves BP1HARDINS 1806 T/C Normal shutdown Case depressuring post Cooldown Cranking_ 1806 T/C Noma] Compressor Case depressuring volume. AM 5 minutes No No Yes BPIHARDINS 1806 T/C Normal shutdown Case depressuring post Waterwash Cranking. 1802 T/C (standby unit) Brought online. 1801 T/C troubleshooting suspected vibration/instrumentation malfunction. BP1 HARDINS Volume (MSCF) 442 85 240 240 240 350 Flare Start Date 5/1/2007 Flare End Date 5/31/2007 Determination Cause 1802 T/C Normal shutdown. Unit returned to Standby Mode. 1801 T/C was previously brought online. Action Taken Time Of Flaring Report Number Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume (MSCF) System 07 -177 Cat Slowdown 5/6/2007 3:10:00 PM 3:15:00 PM 5 minutes No No Yes BP1 \CARVERWJ 3 Action Taken Action Taken Action Taken FS3 Flare Report 1802 T/C Normal shutdovm case depressuring volume. 07 - 179 Cm Slowdown 5/7/2007 4:50:00 PM 4:55:00 PM 5 minutes No No Yes BP1\HARMS 240 Determination Cause Case depressure after normal stop on 1806 AL T\C system after trouble shooting Hydraulic pressure problem Action Taken Case depressured and flare stopped. 07 -180 Ctrl Slowdown 5/8/2007 1:46:00 PM 1:51:00 PM 5 minutes No No Yes BP1 \CARVERWJ 240 Determination Cause 1806 T/C Normal shutdown for required maintenance activity. Hydraulic ON Pump discharge pressure adjustments. 1806 T/C Normal shutdown case depressudng volumes. 07-180 Ctrl Slowdown 5/8/2007 4:20:00 PM 4:25:00 PM 5 minutes No No Yes BP1 \CARVERWJ 240 Determination Cause 1806 T/C Normal shutdown for required maintenance activity. Hydraulic Oil Pump discharge pressure adjustments. Action Taken 1806 T/C Normal shutdown case depressudng volumes. 07 -188 Ctrl Slowdown 5/11/2007 9:24:00 AM 9:29:00 AM 5 minutes No No Yes BP1 \CARVERWJ 240 Determination Cause 1806 T/C Normal shutdown while performing maintenance on Hydraulic Oil system. 1806 T/C normal shutdown case depressuring volume. 07 -186 Cm Slowdown 5/11/2007 10:50:00 AM 10:55:00 AM 5 minutes No No Yes BP1 \CARVERWJ 240 Determination Cause 1806 T/C Normal shutdown while performing maintenance on Hydraulic ON system. 1806 T/C normal shutdown case depressudng volume. Flare Start Date 5/1/2007 Flare End Date 5/31/2007 Report Number System 07 -186 Flare Relief 5/11/2007 11:40:00 AM 12:50:00 Determination Cause Action Taken 07 Ctrl Slowdown 5/11/2007 1:23:00 PM 1:28:00 P Determination Cause Action Taken FS3 Flare Report Time O1 Flaring Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By PM 7o minutes Yes No No Intermittent flaring from Slug Catchers due to temporary excessive inlet gas volumes. Well 7 -30 P.O.P. after being shut-in for extended period of time. Production from wells 7 -22, 7 -5, and 7 -17 trimmed to minimum. Additionally, production from 7 -30 was also trimmed back to eliminate flare activity. M 5 minutes No No Yes BP1 \CARVERWJ 1806 T/C normal shutdown while performing maintenance on Hydraul CM system. 1806 T/C normal shutdown case depressuring volume. 07 -188 Ctrl Slowdown 5/11/2007 2:47:00 PM 2:52:00 PM 5 minutes No No Yes BP1CARVERWJ Determination Cause 1802 T/C Normal shutdown after 1801 T/C unit was brought online. Action Taken 1802 T/C nomnal shutdown case depressuring volumes. 07 -212 Cm Slowdown 5/30 /2007 2:10:00 PM 9:15:00 PM 425 minutes No No Yes BP1 \CARVERWJ Determination Cause 1801 T/C shutdown to enable maintenance on 1802 T/C for Power Turbine repair. Units were required to be shutdown for 1802 Coupling disassembly. Unfortunately, 1801 T/C wasn't able to be Action Taken started/brought online due to Coupling "Locked Up'. This required unplanned maintenance to be performed on 1801. 1801 T/C Coupli g 'Lock Up' corrected and unit was brought online. BP1\CARVERWJ Volume (MSCF) 240 3 RE: GPB Gas Flaring Incident Subject: RE: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com> Date: Sun, 06 May 2007 14:46:51 -0800 To: steve_mcmains@admin.state.ak.us CC: "GPB, Environ TL" <GPBEnvironTL@BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast@BP.com >, "Fiedler, Anne M" <Anne.Fiedler@bp.com >, "Benson, Gary' A" <Gary.Benson @bp.com >, "Pfeiffer, Jim A" <Tim.Pfeiffer@bp.com >, "Kurz, John" <john.kurz @bp.com >, "GPB, FS3 OTL" <GPBFS3OTL@bp.com >, "GPB, Area Mgr Central (GC1 /3/FS3)" <GPBAteaMgrCentral@BP.cdfhi> To Steve McMains, AOGCC steve_mcmains @admin state. ak. us 907-793-1241, fax 907 - 276 -7542 From: Dwight Warner, GPB Field Optimization Engineer for Hal Tucker, GPB Prod Optimization Team Leader Extended flaring events occurred on May 5 at Greater Prudhoe Bay. The event occurred at FS3 when 1801 turbine compressor unexpectedly shutdown from suspected high vibration /instrument malfunction. 1802 (standby unit) was brought online to eliminate flaring. Flaring occurred from 1148 to 1258 (70 minutes), total volume flared was 350 MSCF. Also, on the same day there was intermittent flaring on 1806 AL machine while preparing for a water wash, compressor case de- pressuring, and during normal shutdown for case de- pressuring post water wash cranking (4 five minute events). The total volume for these intermittent events was 875 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner GPB Field Optimization Engineer (907) 659-4382 for Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 f of 1 5/7/2007 6:19 AM GPB Gas Flaring Incident Subject: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com> Date: Sun, 20 May 2007 14:39:21 -0800 To: steve_mcmains @admin.state.ak.us CC: "GPB, Environ TL" <GPBEnvironTL @BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast @ BP.com>, "Fiedler, Anne M" <Anne.Fiedler @bp.com >, "Benson, Gary A" <Gary.Benson @bp.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer @bp.com >, "Kurz, John" <john.kurz @bp.com>, "GPB, FS3 OTL" <GPBFS3OTL @bp.com >, "GPB, Area Mgr Central (GCI /3/FS3)" <GPBAreaMgrCentral @ BP.com>, "GPB. FS2 /COTU OTL" <GPBFS2OTL @bp.com >, "GPB, Area Mgr East (FSI /2 /COTU /Seawater)" <GPBAreaMgrEastFS 12CS @BP.com> To: Steve McMains, AOGCC steve mcmains @admin.state.ak.us 907 - 793 -1241, fax 907- 276 -7542 From: Hal Tucker, GPB Prod Optimization Team Leader Two extended flaring events occurred last week at Greater Prudhoe Bay. One event occurred at FS3 on May 11, due to excessive slug catcher gas volumes. Four wells were choked back, including well 7 -30 which had been brought on following a lengthy shut in period, to reduce the gas rate and eliminate the flaring. Flaring occurred from 1140 to 1250 (70 minutes), total volume flared was 941 MSCF. The other event occurred at FS2 on May 19, at 1:45 AM. LPS machine 1804 was shut down in preparation for a hot gas path inspection and was spin cooled, per the procedure, for four hours. The total volume for the event was 833 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 f of 1 5/21/2007 8:27 AM GPB Gas Flaring Incident Subject: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com> Date: Fri, 01 Jun 2007 14:58:51 -0800 To: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com >, steve_mcmains @admin.state.ak.us CC: "GPB, Environ TL" <GPBEnvironTL@BP.com>, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast @BP.com >, "Fiedler, Anne M" <Anne.Fiedler @bp.com >, "Benson, Gary A" <Gary.Benson@bp.com >, "Pfeiffer, Jim A" <Jim.Pfeiffer @bp.com >, "Kurz, John" <john.kurz @bp.com >, "GPB, FS3 OTL" <GPBFS3OTL @bp.com >, "GPB, Area Mgr Central (GC1 /3/FS3)" <GPBAreaMgrCentral @BP.com> To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907- 793 -1241, fax 907- 276 -7542 From: Dwight Warner, GPB Prod Optimization Team Leader An extended flaring events occurred last week at Greater Prudhoe Bay. The event occurred at FS3 on May 30. 1801 T/C was shutdown to enable maintenance on 1802 T/C for Power Turbine repair. The units were required to be shutdown for 1802 Coupling disassembly. 1801 wasn't able to be started and brought online due to Coupling being "locked up ". This required unplanned maintenance to be performed on 1801. The 1801 T/C Coupling "lock up" was repaired and the unit was brought on fine. Flaring occurred from 1410 to 1915 (425 minutes), total volume flared was 2656 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner GPB Prod Optimization Team Leader (907) 659 -4472 1 of 1 6/I/2007 3:I0 PM 1. Facility Number 12 Facility Name 0290000030 PBU FS 3 3 Field PBU - EOA 4. Dp.ra r BP 15. Month/Yew of Clposton !June -2007 Dlapoettlal Volume MCF 20. For production from multiple pools, Net conttoton of .ash pool as • prawn of Total Volume O. Sold 0 Pool beams Pool Code Percent 7 Reti�eOMd 0 PRUDHOE 840150 100.00% 8. Fared or veined l hour or leas 245 / Flared hour 2,357 ,/ 9 or van mom than 1 (.n me.) 10. Not end Purge 32,946 , 11. Used for lsa» r E D 946,689 Aulhonatbn ,1 hr Safety Z( 3l7 MCF \ 12. Other fees FrosuctldnD) l REM 13. TOTAL VOLUME REM b12)JUL 2 3 ZOO! 7 982,237 Lease Use MCF 14. Nt3L13a EaNWOt_k_ & Gas Cons Conwnisek3n 0 m Ca.rvatlan Ma Anchorage 15. Pmdxaaad gee o Waage: 1""'r 7 tea Transferred from: CGF 970,, 63 /� /D ei � _ _ 1 t � ~ �/j Camrtdaagrw 7 n - o Owe 17. Trala erred to (Express as • negative e) CGF - 27,963,181 18. Remarks: Block 11 Fuel Gas = 937,237 inset and Assist Gas = 9,452 ntscf 1 herby certify that the foregoing Is and correct 10 ere best of my knowledge. sgreve / e Manager, Production Taxes and Royalty Tae Notc All volume must be corrected to pressure of 14.65 s al and to a temperature of 60o F. Authority 20 AAC26.235. ((((//// PNrMd Name Bernard . Hajny Pilo,,. (907)584-5038 Dar 7 0 'C 7 Form 10 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate (Unplanned Events less than or equal to 1 hour DATED. ..... TINE„ f ,. VCtUME,,,,, DESCRIPTION OF INCIDENT & CAUSE 6/9/2007 0908 -0913 3 Not required for unplanned events which 6/9/2007 0930 -0940 6 are Tess than or equal to 1 hour 3 6/9/2007 0945-0950 6/16/2007 0845-0850 6/21 /2007 1230 -1235 6/23/2007 1418 -1421 6/23/2007 1513 -1516 6/23/2007 1530 -1535 6/27/2007 1540 -1545 TOTAL 3 3 17 18 3 3 59 6/21/2007 0915-1230 1,151 TOTAL 2,357 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-3 OAS FLARING INCIDENT REPORT June 2007 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour (Unplanned Events greater than 1 hour DATE„,„„„„„,—, TIIE.,m. ■ VOLUME. - DESCRIPTION OF INCIDENT & CAUSE,p, mr,nspramtorwei ACTION TAKEN TO ELIMINATE CAUSE. 6/6/2007 1547 - 1900 1206 See attachments See attachments )Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE,,,,„, VOLUME DESCRIPTION OF INCIDENT & CAUSt rutrawnwngffr ip r ACTION TAKEN TO ELIMINATE CAUSE,,, 6/3/2007 1230 -1235 60 See attachments See attachments 6/3/2007 1525 - 1530 60 6/4/2007 1330 - 1335 60 6/12/2007 0410-0415 3 6/27/2007 1625 -1630 3 TOTAL 186 Page 1 7/11/2007 2:32 PM ■ 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf pia TOTAL Unplanned Events < 1 Hour 59 Unplanned Events > 1 Hour 2,357 Planned Events < 1 hour and not 188 exceeding 5,000 MCF Planned Events • 1 hour or 0 exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME TOTAL 0 R 45.000 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT • FS OAS FLARING INCIDENT REPORT June 2007 DATE TIME, ., VOLUME kw DESCRIPTION OF INCIDENT E CAUSE r , ACTION TAKEN TO ELIMINATE CAUSE See attachments See attachments Page 2 1 7/11/2007 2:32 PM Flare Start Date 8/1/2007 Flare End Date 6/30/2007 FS3 Flare Report Report System Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 07.218 Ctrl Slowdown 8/3/2007 12:30:00 AM 12:35:00 AM 5 minutes No No Yes BP1 WARDINS 60 Determination Cause Normal Stop and case depressure on 195 T/C 1803 for cooling and scheduled ONC watenwash. Action Taken 07-216 Ctrl Slowdown 07-217 Ctrl Slowdown Flare stopped after case depressured. 8/3.2007 3:25:00 PM 3:30:00 PM 5 minutes No No Yes BPIWARDINS 80 Determination Cause Normal stop and case depressure on 1803, atter bringing to idle to dry post water wash, for Automation and FCC of the Demister system Flare stopped after case depressured. Action Taken 6/4/2007 1:30:00 AM 1:35:00 AM 5 minutes No No Yes Determination Cause 1804 T/C Normal shutdown in preparation for maintenance (watenwash VIOV Irnp L.O. filter maintenance) Action Taken 1804 T/C normal shutdown Compressor Case depressuring. BP1\CARVERWJ 60 07 Ctrl Slowdown N... 6/6/2007 3:47:00 PM 7:00:00 PM 193 minutes No No No BP1 \CARVERWJ 1206 Determination Cause 1801 T/C shutdown due to Control Pans1lnstmrnentation malfunction. Unfortunately, several start attempts were made prior to a successful Action Taken startup. 1801 T/C brought online after Coupling lockup problem was corrected. Report System Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (msct) 07-230 Ctrl Blowdown 6/12/2007 4:10:00 AM 4:15.00 AM 5 minutes No No Yes BP1 \CARVERWJ 3 Determination Cause 1801 T/C normal shutdown Case depressuring for maintenance. Cooping to be replaced due to 'baring up 1801 T/C normal shutdown Case depressuring volume. 1802 T/C was previously brought online. 07-253 Flare Relief 07-263 CM Blowdown Action Taken 6/21/2007 9:15:00 AM 12:30:00 PM 195 minutes Yes No No Determination Cause STV -IP T\C 1801 unloaded due to temperature. Added NGL's to no avaa, troupe shoot reason for GG RPM drop. Action Taken Started STV -IP T/C 1802 and shut down 1801 6/27/2007 4:25:00 PM 4:30:00 PM 5 minutes No No Yes 13P1\GARSKEN 3 Determination Cause 1802 was shutdown because 1801 was put on tine. Completed depresauing. Action Taken FS3 Flare Report BP1V'RESLEDK 1151 I di Subject: GPB Gas Flaring Incident From: "GPB, Prod Opt TL" <GPBProdOptTL @BP.com> Date: Fri, 22 Jun 2007 08:49 :33 -0800 To: steve_mcmains@admin.state.ak.us CC: "GPB, Environ TL" <GPBEnvironTL @BP.com >, "GPB, Environ Advisor East" <GPBEnvironAdvisorEast@BP.com>, "GPB, Environ Advisor West" <GPBEnvironAdvisorWest@BP.com>, "Fiedler, Anne M" <Anne.Fiedler@bp.com>, "Benson, Gary A" <Gary.Benson@bp.com>, "Pfeiffer, Tim A" Uun.Pfeiffer@bp.com>, "Kurz, John" <john.kurz@bp.com>, "GPB, GC1 OTL" <GPBGC1OTL@bp.com>, "GPB, FS1 OTL" <GPBFSIOTL @bp.com>, "GPB, FS3 OTL" <GPBFS3OTL @bp.com>, "GPB, GPMA OTL" <GPBGPMAOTL @bp.com>, "GPB, Area Mgr Central (GC I/3/FS3)" <GPBAreaMgrCentral@BP.com>, "GPB, Area Mgr East (FS1 /2/COTU /Seawater)" <GPBAreaMgrEastFS12CS@BP.com>, "GPB, Area Mgr North (Gas Plants/GPMA)" <GPB_AreaMgrNorth@BP.com>, "GPB, Optimization Engr" <GPBOptimizationEngr@BP.com> sieve mcmains @admin.state.ak.us 907- 276 -7542 Team Leader Extended flaring events occurred at four GPB facilities on June 21 due to high ambient temperature (- 70 deg). The high ambient caused problems with the stability of the 2nd and 3rd stage compression at FS1, FS3, GC1 and GPMA. Flaring occurred as follows: volume flared intermittent), volume flared intermittent), To: Steve McMains, AOGCC 907 - 793 -1241, fax From: Hal Tucker, GPB Prod Optimization FS1 14:59 to 16:00 was 2200 MSCF; FS3 09:15 to 12:35 total volume flared was 1154 MSCF; GC1 13:40 to 15:59 was 676 MSCF; GPMA 14:33 to 17:56 total volume flared was 38 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659 -4472 (61 minutes), total (200 minutes, (139 minutes), total (203 minutes, rvinmaiLdat Content -Type: application/ms -tnef Content - Encoding: base64 6/22/2007 9:34 AM 1 Facility Number 0290000030 2 Faality Name PBU FS 3 3 Feld PBU - EOA 4. Operator BP 5. MondWwQ of Disposition July - 2007 Disposition Volume MCF / / 20. For production from multiple pools. fist contribution of each pool as a percent of Total Voksne 6 Sold 0 Pool Name Pool Code Percent T Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 hour or less 1,070 9. Flared or versed more than t hots (ses instr.) 12,719 10. Mot and Purge 33,782 11 Used for lease operations (specify in Remarks) 837.318 12. Other (see instructions) 0 Official Use Only ,..-. Authorization . -1 nr. MtY I I Q MCF 13. TOTAL VOLUME (ITEMS 6-12) 884.889 Lease Use MCF 14. tea Gas Equivalent 0 Conservation MCF 15. Purchased gas 0 Waste MCF 18. Transferred front CGF 860,550 'F�/��,�' /, /, W ' 2 7 f � (/ � r � / / f`� Y mi Ba S tier (j ! O Z � 7 n. Transferred t (Express as a negative tive s) CGF - 27,005,387 / n � 18. Remarks. Block 11: Fuel Gas = 826,768 nucf and Assist Gas = 10.550 mist I hereby certify that the for correct to true d corre to the best of my knowledge. 66 Signature /� Tide Manager, Production Taxes and Royalty Note: All volumes must be corrected to pressure of 14.65 psla and to a temperature of 60o F. Authority 20 AAC25.235. (!! , Printed Name Bernard W. Hajny Phone (907)564 -5028 Date ,1 0 7 Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT July 2007 1 (Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 7/2/2007 2045 -2050 202 Not required tor unplanned events which 7/3/2007 1025 -1028 58 are less than or equal to 1 hour 7/10/2007 1724 -1730 240 TOTAL 500 1 'Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 7/13/2007 1100 -1712 TOTAL 875 See attachments 875 1 'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 7/2/2007 1600 -1605 240 See attachments 7/3/2007 2223 -2232 4 7/4/2007 0930 -0935 7/412007 1952 -1957 7/10/2007 2123 -2128 7/14/2007 1330 -1350 7/24/2007 0830 -0840 TOTAL 3 5 3 75 240 570 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 1 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf VOLUME DESCRIPTION OF INCIDENT & CAUSE 391 See attachments 400 131 8,304 2,492 126 DATE 7/3/2007 7/20/2007 7/26/2007 7/26 - 30/2007 7/31/2007 7/31/2007 TIME 2235 -2350 0200 -0600 1103 -1400 1600 -1140 0710 -2400 0716 -0830 TOTAL 11,844 ACTION TAKEN TO ELIMINATE CAUSE See attachments Pape 8/10/2007 9:50 AM TOTAL Unplanned Events < 1 Hour 500 Unplanned Events > 1 Hour 875 Planned Events < 1 hour and not 570 exceeding 5.000 MCF Planned Events > 1 hour or 11,844 exceeding 5,000 MCF Pilot Purge 33,782 Assist 10,550 TOTAL FLARED VOLUME 58,121 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT July 2007 Page 2 8/10/2007 9:50 AM Flare Start Date 7/1/2007 Flare End Date 7/31/2007 Report System FS3 Flare Report Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 07 -269 Controlled Blowdown 7/2/2007 400 PM 4:05:00 PM 5 minutes No No Yes BP1\HARDINS 240 Determination Cause Normal Case depressive when 1806 AL T\C system was shutdown for High ambient temps and A/L system optimization by using the WOA GLTs Action Taken Flare quit when case depressured. 07 -271 Flare Relief 7/3/2007 102300 PM 10:32:00 PM 9 minutes No No Yes BP1 \GARSKEH 4 Determination Cause Attempted to bleed down B HP gas into the B IP system to minimize flaring while depressuring B HP trait for planned Maintenance - 1801 Action Taken compressor could not handle the extra gas. Shut down the deeding into the B IP system. 07 -271 Flare Relief 7/3/2007 1035:00 PM 1150 PM 75 minutes No No Yes BPI \GARSKEH 391 Determination Cause Depressured B HP Seperator, B HP Gas Scrubber and B HP Gas Scbr Liquid Pot to HP flare for planned Maintenance on L14 -IC. Action Taken Vessels depressured to zero and flare quit 07 -275 Controlled Slowdown 7/4/2007 9:30:00 AM 9:35:00 AM 5 minutes No No Yes BP1lHARDINS 3 Determination Cause STV -IP PC 1801 normal stop due to poor performance with high ambient temps Action Taken Flare stopped when case depressured 07 -275 Controlled Blowdown 7/4/2007 7:52:00 PM 7:57:00 PM 5 minutes No No Yes BPI \HAROINS 5 Determination Cause Bled down the case on 1806 Compressor for problems associated with the seal oil system. Action Taken Case oepressured and valve was dosed 07 -281 Controlled Slowdown 7/10/2007 923:00 AM 9:28:00 AM 5 minutes No No Yes BP1 \GARSKEH 3 Determination Cause STV - PC 1802 shutdown due to available run time hours and cooler ambient temps. Action Taken Started and loaded STV /IP TLC 1801. Flare Start Date 7/1/2007 Flare End Date 7/31/2007 Report System Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mad) 07 -287 Controlled Slowdown 7/13/2007 11:00:00 AM 5:12:00 PM 372 minutes Yes No No BP1UMEADJW 875 Determination Cause 1801 T/C SPORADIC LOSS OF COMPRESSION DUE TO HIGH AMBIENT TEMPERATURES. Action Taken FS3 Flare Report ADJUSTING 1801 T/C TO GET COMPRESSOR TO PICK - UP LOAD. 07 -290 Controlled Blowdoym 7/14/2007 1:30:00 AM 1:50:00 AM 20 minutes No No Yes BPI \MEADJW 75 Determination Cause 1806 T/C start up purging. Pureging completed and T/C brought on - line. Action Taken. 07 -296 Controlled Slowdown V 7/20/2007 2:00:00 AM 6:00:00 AM 240 minutes No No Yes BP1 \MEADJW 400 Determination Cause COMMON -LINE 6C/13B ISOLATED AND DEPRESSURED TO FLARE FOR MAINTENANCE. Action Taken ISOLATION AND DEPRESSURING COMPLETED. 07 -299 Controlled Blowdown 7/24/2007 830:00 AM 8:40A0 AM 10 minutes No No Ves BP1 \MEADJW 240 Determination Cause 1806 T/C shut down for Stand -by service. Compressor case and piping depressured. Action Taken Depressuring completed and T/C secured. 07-300 Controlled Slowdown `- 7/26/2007 11:03:00 AM 2:00:00 PM 177 minutes No No Ves BP1tCARVERWJ 131 ✓ Determination Cause 14B/C Canmonline shutdown and depressured due to corrosion concerns. Depressuring was necessary to enable continued Corrosion Action Taken monitoring/evaluation. 148/C ComrtwNine depressuring completed. Flare Start Date 7/1/2007 Flare End Date 7/31/2007 FS3 Flare Report Report System \ . Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (msct) 07 -300 Controlled Slowdown 4 7/26/2007 4:00:00 PM 12:00:00 AM 480 minutes No No Ves BP1\CARVERWJ 725 Determination Cause Commonline 14B/C lined up to flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was Action Taken not noted at time. Pressure was maintained during maintenance activities. 07 -313 Controlled Blowdown "4 7/27/2007 12:00:00 AM 12:00:00 AM 1440 minutes No No Ves BPI \MEADJW 2174 s e Determination Cause Commonline 14B/C lined up to flare hader to hold pressure on line as tow e5 possible during maintenance work. Excessive gas leakage was Action Taken not noted at time. Line pressure mantained during maintenance work. 07 -314 Controlled Blowdown \, 7/28/2007 12:00:00 AM 12.'00:00 AM 1440 minutes No No Yes BPI \MEADJW 2174 / Determination Cause Commonline 14B/C lined up to flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was Action Taken not noted at time. Low line pressure maintained during maintenance work. 07 -315 Controlled Slowdown V 7/29/2007 12:00:00 AM 12:00:00 AM 1440 minutes No No Yes 13P1 \MEADJW 2174 ✓ Determination Cause Commonline 148/C lined up to flare hader to hold pressure on line as tow as possible during maintenance work. Excessive gas leakage was Action Taken not noted at time. Low line pressure maintained during maintenance work. 07-316 Contrdied Blowdown V 7/30/2007 12:00:00 AM 11:40:00 AM 700 minutes No No Ves BP1 \MEADJW 1057 Determination Cause Commonline 14B/C lined up to flare hader to hold pressure on line as kwv as possible during maintenance work. Excessive gas leakage was Action Taken not noted at time. Low line pressure maintained until line was secured. Flare Start Date 7/1/2007 Flare End Date 7/31/2007 FS3 Flare Report Report System Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 07 -305 Controlled Blowdown 7/31/2007 7:10:00 AM 12:00:00 AM 1010 minutes No No Yes BPICARVERWJ 2492 Determination Cause Conmmnline 148/C lined up to Care hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was Action Taken not noted at time. Low line pressure maintained for maintenance work. 07 -305 Controlled Blowdown \ V 7/31/2007 7:18:00 AM 8:30:00 AM 74 minutes No No Yes Determination Cause DS14B/C Contmonline depressured to Aare to enable additional corrosion inspections and corrosion repairs. Action Taken DS14B/C Commonline depressuring completed. Which enabled work to proceed on corrosion inspection and repairs. BP1 \CARVERWJ 128 '� McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL @BP.com] Sent: Wednesday, July 04, 2007 7:57 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, FS3 OTL; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, Optimization Engr Subject: GPB Gas Flaring Incident To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 -793 -1241, fax 907- 276 -7542 From: Dwight Wamer, GPB Prod Optimization Team Leader A flaring event at FS3 occurred on 7/3/07 while depressuring the B HP separator, B HP gas scrubber, and the B HP gas scrubber liquid POT to the HP flare system for planned maintenance on L14 -IC. The vessels were depressure to zero psig and the flaring stopped. Flaring began at 22:35 and ended at 23:50 (75 minutes), total volume flared was 391 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner GPB Prod Optimization Team Leader (907) 659 -4472 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL (GPBProdOptTL a@BP.comj Sent: Saturday, July 14, 2007 9:51 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, FS3 Olt GPB, Area Mgr Central (GC1 /3 /FS3); GPB, Optimization Engr Subject: GPB Gas Flaring Incident To: Steve McMains, AOGCC steve mcmains@admin.state.ak.us 907- 793 -1241, fax 907 - 276 -7542 From: Hal Tucker, GPB Prod Optimization Team Leader An extended flaring event occurred at FS3 on 7/13/07 due to high ambient temperatures. Intermittent flaring occurred while ambient temperatures reached levels above 60 deg. Turbine /compressor 1801 was adjusted frequently during this period to get it to load up and remain loaded. Intermittent flaring began at 1100 and ended at 1712 (372 minutes), total volume flared was 875 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL @BP.com] Sent: Saturday, July 21, 2007 6:39 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, FS3 OTL; GPB, Area Mgr Central (GC1 /3/FS3); GPB, Optimization Engr Subject: GPB Gas Flaring Incident To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 -793 -1241, fax 907 -276 -7542 From: Hal Tucker, GPB Prod Optimization Team Leader An extended flaring event occurred at FS3 on 7/20107 when common line 6C /13B was de- pressured so that it could be safed out for maintenance. Flaring duration was 240 minutes, total volume flared was 400 MSCF. if you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL iGPBProdOptTL @BP.com] Sent: Thursday, July 26, 2007 6:27 PM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, FS3 OTL; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, Optimization Engr Subject: GPB Gas Flaring Incident To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 -793 -1241, fax 907- 276 -7542 From: Hal Tucker, GPB Prod Optimization Team Leader An extended flaring event occurred at FS3 on 7/26/07 when common line 14B /C was de- pressured to make corrosion repairs. Flaring duration was 177 minutes, total volume flared was 131 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Prod Optimization Team Leader (907) 659-4472 1 1 Fealty Numbe, 0290000030 2 Facility Name PBU FS 3 3. Field PBU - BOA 4 Operator BP 5 Month/Year of Disposition Auqust - 2007 Disposition Volume MCF 29. For production from multiple pools, list corn ibuuon 0( each pool as a percent of Total Volume 6. sow 0 Pool Name Pool Code Percent 7 ReinleOted 0 PRUDHOE 640150 100.00% 9. Flared or vented 1 hour or less 2,435 a Flared Or vented more than 1 has (see Instr.) 13,383 10 Riot and Purge 55,944 11 Used la base operations (spedry in Remarks) 831.994 - 12. Omer (see i struceons) 0 Official Use Only AuRgrizahOn >1 nr �� Safety I 3$.3 MCF 13. TOTAL VOLUME (ITEMS 612) 903,756 Lease Use MCI' 14 NGL Gas Equivalent 0 Conservation MCF 15. Purchased gas 0 Waste. MCF I9. Transferred from: CGF 872,198 a/ /0 -/7– C 7 �Comms 7' Date 17 Translemed to (Express as a negative 0) CGF - 22.956.138 t6. Remarks. Block I I: Fuel WI= 816,254 ntsct and Assist Gas = 15,740 inset I hereby certify that rote , • • soanae • 1s true - • coned 10 the best of my knowledge. / Tiee Manager, Production Taxes and Royalty Note: All volumes must be corrected to pressure of t4.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. Ar d Printed Name Bemard Hajny Phone (907)564 - 5020 Date 9/, 7 Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate !Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 8/9/2007 1024 -1100 9 Not required for unplanned events which 8/15(2007 0245 -0315 575 are less than or equal lo 1 hour 8/17/2007 0730 -0830 551 8/18/2007 0935-0940 1 8/18/2007 1020 -1025 3 8/18/2007 2000 -2010 240 8/19/2007 1415 -1435 7 8/19/2007 1430 -1440 240 8/19 /2007 1715 -1737 10 8/20/2007 0043 -0107 8 8/26/2007 1340 - 1350 80 8/29/2007 1153 -1207 2 8/29/2007 1527 -1542 6 TOTAL 1,732 Unplanned Events greater than 1 hour 1 DATE 8/12/2007 8/12/2007 8/13/2007 8/13/2007 DATE 8/1/2007 8/1/2007 8/1/2007 8/2/2007 8/11/2007 8/11/2007 8/12/2007 8/12/2007 8/25/2007 8/25/2007 TIME 1022 -1135 1442 -1810 0235 -0623 1020 -2245 TOTAL TIME 1325 -1328 1410 -1413 1445 -1448 0725 -0800 1625 -1630 1700 -1705 1415 -1420 1510 -1520 0304 -0315 0346 -0430 VOLUME DESCRIPTION OF INCIDENT & CAUSE 38 See attachments 217 115 346 716 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT August 2007 VOLUME DESCRIPTION OF INCIDENT & CAUSE 3 See attachments 3 3 130 3 3 3 3 7 340 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments !Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf 1 ACTION TAKEN TO ELIMINATE CAUSE See attachments Page 1 9/12/2907 11:08 AM 8/25/2007 8/25/2007 8)25/2007 DATE 8/1/2007 8/2- 6/2007 8/8- 9/2007 8/25/2007 8/25/2007 0404 -0410 0700 -0710 0905 -0940 TOTAL TIME 0000 -1736 1300 -2045 1900 -1300 0038 -0257 0635 -0750 TOTAL Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 60 1 144 703 !Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 1 VOLUME DESCRIPTION OF INCIDENT & CAUSE. 1,595 See attachments 9,398 1,540 67 67 12,667 TOTAL 1,732 716 703 12,667 55,944 15,740 87,502 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT August 2007 ACTION TAKEN TO ELIMINATE CAUSE See attachments Page 2 9/12/2007 11:08 AM Flare Start Date 8/1/2007 Flare End Date 8/31/2007 FS3 Flare Report Report System Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 07 -307 Ctrl Blowdown x'8/1 /2007 12:00:00 AM 5:36:00 PM 1056 minutes No No Ves BP1 \GARSKEH 1595 Determination Cause Comnonline 14B/C lined up to flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was not noted at time. • Action Taken Low line pressure maintained during manitenance work unt11 line was secured. 07 -307 CM Slowdown 8/1/2007 125:00 PM 138:00 PM 3 minutes No No Ves BPI \GARSKEH 3 Determination Cause 1802 SD on hi vib on start Action Taken Completed depressuring. 07-307 Ctrl Slowdown 8/1/2007 2:10:00 PM 2:13:00 PM 3 minutes Yes No Yes BPIIGARSKEH 3 Determination Cause 1802 SD on hi vib during start-up. Action Taken Competed depressuring. 07 -307 CtrlBowdown 8 %1/2007 2:45:00 PM 2:48:00 PM 3minutes Yes No Yes BP1 \GARSKEH 3 Determination Cause TIC 1801 shutdown for planned maintenance, put 1802 en line. Action Taken Completed depressuring. 07-309 CM Slowdown 8/2/2007 7:25:00 AM 8:00:00 AM 35 minutes No No Ves BP1\GARSKEH 130 Determination Cause Depresured 14BC CL to attempt maintainence. Action Taken Completed depressuring. Flare Start Date 8/1/2007 Flare End Date 8/31/2007 FS3 Flare Report Report System Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 07-309 CM Blowdown \1 8/2/2007 1:00:00 PM 12:00:00 AM 880 minutes No No Yes BP1 \GARSKEH 996 Determination Cause Commonline 148/C lined up to flare trader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was not noted at time. Action Taken Low Noe pressure was maintained during maintenance work. 07 -317 Chi Bbwdown v 8/3/2007 1200:00 AM 12:00:00 AM 1440 minutes No No Yes BPI \MEADJW 2174 Determination Cause Commonline 148/C lined up to flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was not noted at time. Action Taken Low tine pressure maintained during maintenance work. 07 -318 CM Blowdown 8/4/2007 12:00:00 AM 12:00:00 AM 1440 minutes No No Yes 8P1\MEADJW 2174 Determination Cause Commonline 14B/C lined up r0 flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was not noted at tine. Action Taken Low line pressure maintained during maintenance work. 07 -319 CM Blowdown V 8!5/2007 12:00:00 AM 12 AM 1440 minutes No No Yes BP1\MEADJW 2174 Determination Cause Commonline 14B/C lined up to flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was not noted at time. Action Taken Low line pressure maintained during maintenance work. Flare Start Date 8/1/2007 Flare End Date 8/31/2007 Report System 07-320 Ctrl Blowdown 07 - 312 CM Slowdown 07-312 CM Slowdown 07-321 Ctrl Bowdown FS3 Flare Report Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (msct) V 8/6/2007 12:00:00 AM 8:45:00 PM Action Taken Action Taken Action Taken 1245 minutes No No Yes Determination Cause Commontine 148/C lined up to flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was not noted at time. towline pressure maintained during maintenance work until secured. BPIWEADJW 1880 \ 4/8/2OO7 7:00:00 PM 12:00:00 AM 300 minutes No No Yes BP1\MEADJW 80 Determination Cause Depressuring 14B/C comrnonline to flare to allow leak rate testing. Action Taken Line depressured. h 8/8/2007 8:20:00 PM 12:00:00 AM 220 minutes No No Yes BP1 \MEADJW 302 Determination Cause Ccmmonline 14B/C lined up to flare hader to hold pressure on line as low as possible dunng maintenance work. Low the pressure maintained during maintenance work. V8/9/2007 12:00:00 AM 1:00:00 PM 780 minutes No No Low line pressure maintained during maintenance work unti linw was secured. Yes Determination Cause Commorlline 146/C lined up to flare hader to hold pressure on line as low as possible during maintenance work. Excessive gas leakage was not noted at tine. BP1\MEADJW 1178 Flare Start Date 8/1/2007 Flare End Date 8131 /2007 FS3 Flare Report Report System Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 07 -325 Ctrl Blowdown 8/11/2007 4:25:00 PM 4:3000 PM 5 minutes No No Ves SP1 \MEADJW 3 07 -325 Ctrl Slowdown 8/11/2007 5.00:00 PM 5:05:00 PM 5 minutes No No Ves BPI \MEADJW 3 07 -329 Flare Relief V 8/12/2007 1022:00 AM 11:35:00 AM 73 minutes Yes No No BPI\MEADJW 38 Determination Cause 1806 AL compressor unloaded due to Fieldwide AL System conditions. This caused the AL compressor gas load to back into the Residue Gas system which momentarily caused the HP Operational Flare to activate. Action Taken Unit was reloaded and attempted to be optimized for the curent AL System conditions. 07-329 CM Slowdown 8/12/2007 2:15:00 PM 2:20:00 PM 5 minutes No No Ves BPI \MEADJW 3 Determination Cause 1801 T/C SHUTDOWN DUE TO TURBINE OVERSPEED. Action Taken 1801 COMPRESSOR DEPRESSURED AND ISOLATED. 07 -329 Flare Relief V 8/12/2007 2:42:00 PM 811000 PM 208 minutes Yes No No BPI \MEADJW 217 Determination Cause 1806 AL Compressor unloaded due to Fieldwide AL System conditions This caused the AL Compressor gas load to back into the Residue Gas system which momentarily caused the HP Operational Flare to Action Taken activate. Unit was reloaded and attempted to be optimized for the current AL System conditions. 07 -329 Ctrl Slowdown Determination Cause 1801 T/C PURGE COMPRESSOR CASE FOR RESTART AFTER MAINTENANCE. Action Taken 1801 T/C PURGE COMPLETED AND BROUGHT ON -LINE. Determination Cause 1802 T/C SHUT DOWN FOR STAND BY DUTY, COMPRESSOR CASE DEPRESSURED. Action Taken 1802 T/C COMPRESSOR CASE DEPRESSURED AND SECURED. 8/12/2007 3'10:00 PM 3:2000 PM 10 minutes No No Ves BP1 \MEADJW 3 Determination Cause 1801 TIC COMPRESSOR CASE PURGE FOR RESTART. Action Taken 1801 COMPRESSOR PURGE COMPLETED AND MACHINE BROUGHT ON-LINE. Flare Start Date 8/1/2007 Flare End Date 8/31 /2007 Report System 07.356 Flare Rabat 07-356 Flare Relief 07 -346 Flare Relief 07 - 346 Cm °lowdown 07-346 Ctrl Bbwdown Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 8/13/2007 2:35:00 AM 6:23:00 AM 228 minutes Yes NO 140 BP1 \CARVERWJ 115 FS3 Flare Report Determination Cause 1806 AL Compressor unloaded due to Fieldwide AL system conditions. This caused the AL Compressor gas load to back into the Residue Gas System which temporarily caused the HP Operational Flare to activate. Action Taken Unit was reloaded and attempted to be adjusted to current AL. System conditions. V 8/13/2007 10:20:00 AM 10:45:00 PM 745 minutes Ves No No BPI\CARVERWJ 346 Determination Cause 1806 AL Compressor unloaded due to Fieldwide AL system conditions. This caused the AL Compressor gas load to back into the Residue Gas System which temporarily caused the HP Operational Flare to activate. Action Taken Unit was reloaded and attempted to be adjusted to current AL System conditions. 8/25/2007 1238:00 AM 2:57:00 AM 139 minutes Yes No Yes BP1 \GARSKEH 67 Determination Cause Facility Shutdown in support of ALPS Slowdown. 1803 T/C train manually unloading to idle which temporarily caused HP Operational Flare System to exceed its predetermined setpoint. Action Taken Facility production cuts continued in support of ALPS Slowdown which lowered Gas System pressures below HP Operational Flare setpoint. 8/25/2007 3:04:00 AM 3:15:00 AM 11 minutes No No Yes BP7\GARSKEH 7 Determination Cause Depressured 8 train IP sep to 35 psi to assist in 8 Train maintenance. Action Taken Competed shutdown. 8/25/2007 346:00 AM 430:00 AM 44 minutes No No Ves BP PGA RSKEH 340 Determination Cause Depressured CL 78, 7/5C, 7D to atmosphereic pressure for maintenance at DS7 during TAPS SD. Action Taken Completed depressurng. Flare Start Date 8/1/2007 Flare End Date 8/31/2007 Report System 07-346 Ctrl Blowdown 07 -346 Flare Relief 07 -348 Ctrl Slowdown 07 -346 Ctrl Blowdown Action Taken FS3 Flare Report Date Start Time Stop Time Duration Black Smoke Intermittent Planned Reported By Volume (mscf) 8/25/2007 4:04:00 AM 4:10:00 AM 6 minutes No No Determination Cause PC 1803 shutdown for planned maintenance, during TAPS SD. Yes Facility production cuts continued in support of ALPS Slowdown which lowered Gas System pressures below HP Operational Flare setpoint. BP1\GARSKEH 60 Action Taken Completed depressuring. V 8/25/2007 6 AM 7:50:00 AM 75 minutes Ves No Yes BP1\GARSKEH 67 Determination Cause Facility Shutdown in support of ALPS Slowdown. 1806 T/C train manually unloaded to idle which temporarily caused HP Operational Flare System to exceed its predetermined setpoint. 8/25/2007 7:00:00 AM 7:10:00 AM 10 minutes Yes No Ves BPIIGARSKEH 1 Determination Cause Depressured CHD vessel for lockout tag-out maintenance job in 4909. Action Taken Completed depressuring. 8/25/2007 9:05:00 AM 9:40:00 AM 35 minutes Ves No Ves BPI \GARSKEH 144 Determination Cause Depressured DS 14 Commonlines for maintenance at DS 14 during TAPS SD. Action Taken Completed depressuring. • McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTLQBP.com] Sent: Wednesday, August 01, 2007 4:37 PM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL Subject: GPB Gas Flaring Incident To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 -793 -1241, fax 907 - 276 -7542 From. Dwight Wamer, GPB Prod Optimization Team Leader Extended flaring event occurred at FS3 on July 31 while depressuring the DS14 B/C common line to enable additional corrosion inspections and corrosion repairs. Flaring occurred on 7/31107 from 07:16 to 08:30 (74 minutes), total volume flared was 126 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner GPB Prod Optimization Team Leader (907) 659 -4472 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL@BP.com] Sent: Monday, August 13, 2007 1:47 PM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; GPB, Environ Advisor West; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Area Mgr East (FS1 /2 /COTU /Seawater); GPB, Area Mgr Central (GC1 /3 /FS3); GPB, Area Mgr West (GC2/WRD); GPB, FS2 /COTU OTL; GPB, FS3 OTL; GPB, GC2 OTL Subject: GPB Gas Flaring Events To: Steve McMains, AOGCC steve mcmains @admin.state.ak.us 907 -793 -1241, fax 907 - 276 -7542 From: Hal Tucker, GPB Production Optimization Team Leader Three flaring events have recently occurred at GPB. During maintenance activities at FS3, operations discovered that gas had been slowly leaking into the DS 14B /C common line while it was safed -out. The line was left open to the flare as part of the safe -out to ensure that pressure did not build in the line during maintenance activities. A measurable leak rate was not identified until August 9 when the line was blocked in and showed a pressure increase within a short period of time. The line was shut -in and pressure was allowed to build and then opened to the flare to calculate the apparent leakage rate. Flaring from this line ended when 14B/C was lined up to the slug catcher on August 9. The safe -out has been in place since July 26. Flared volume has been calculated to be 23,716 MSCF, and the duration was approximately 10.5 days. An extended flaring event occurred at GC2 on August 11. Flaring occurred during work to repair a leaking nipple on the C -bank oil meter. The GC2 LP compressor was unable to remain loaded due to decreased GC2 oil production while C -bank was taken out of service for trouble shooting and repair operations. The decision was made to leave GC2 partially on line since the repair was likely to be a quick operation. Duration of the event was 6 hours and 30 minutes, total volume flared was 4,062 MSCF. A flare event exceeding 5,000 MSCF occurred on August 12, 2007 at FS2. This event was due to de- pressuring common -lines during facility restart operations. The lines had to be de- pressured to resolve ESD relay problems. Duration of the event was 43 minutes, total volume flared was 5,208 MSCF. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Production Optimization TL (907) 659-4472 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL (GPBProdOptTL @BP.COm] Sent: Friday, August 31, 2007 8:24 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; GPB, Environ Advisor West; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John Subject: GPB Gas Flaring Events To: Steve McMains, AOGCC steve mcmains @admin.state.ak.us 907 -793 -1241, fax 907 - 276 -7542 From: Dwight Warner, GPB Production Optimization Team Leader Flaring events that have recently occurred at GPB. An extended flaring event occurred on August 13th when 1806 AL compressor unloaded due to Fieldwide AL system conditions. This caused the AL Compressor gas load to back into the Residue Gas System which temporarily caused the HP Operational Flare to activate. The Unit was reloaded and attempted to be adjusted to Al System operating conditions. Flaring began at 10:20 and ended at 22:45 (745 minutes). Total volume flare was 346 MSCF. This may be a duplicate but I wanted to make sure you had it. Extended flaring event at F53 also on August 13th when 1806 AL compressor unloaded due to Fieldwide AL system conditions. This again caused the compressor gas load back into the Residue Gas System which temporarily caused the HP Operational Flare to activate. The unit was reloaded and attempted to be adjusted to the current AL system conditions at the time. Flaring began at 02:35 and ended at 06:23 (228 minutes). Total volume flared was 115 MSCF. An extended flaring event occurred on August 25th at FS3 during facility shutdown prior to planned TAPS slowdown. 1803 T/C train manually unloading to idle which temporarily caused HP Operational Flare System to exceed it's predetermined set point. Flaring began at 00:38 and ended at 02:57 (139 minutes). Total volume flared was 67 MSCF. Another extended flaring event occurred on August 25th at FS3 during facility shutdown prior to planned TAPS slowdown. 1806 T/C train manually unloading to idle which temporarily caused HP Operational Flare System to exceed it's predetermined set point. Flaring began at 06:35 and ended at 07:50 (75 minutes). Total volume flared was 67 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner /Alternate Hal Tucker GPB Production Optimization TL (907) 659-5566 1 1 Faciny Number 0290000030 2 Facility Name PBU ES 3 3 Field PBU - EOA 4 Operator BP 5 Month/Year of Disposition September - 2007 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent d Total Volume 6. Sold O r Pool Name Pool Code Percent 7 aesysded 0 PRUDHOE 640150 100.00% 8 Flared or vented 1 hour or less 4,788 9 Flared or vented more than 1 maw (see kus'.) 1,499 10. Pilot and Purge 54,460 -' it Used for lease operations (specify in Remarks) 871,842 12 Omer (see instructions) 0 .. - 1 U9e.QNy . Authorization >1 hr Safety rt MCF 13. TOTAL VOLUME (ITEMS 8-12) 932,567 Lease Use MCF 14 NGL Gas Equivalent 0 Conservation MCF 15. Putman gas 0 Waste. MCF 16. Transferred from: CGF 914,057 17. Transferred to: (Express as a negative e) CGF - 26,672,180 ����//-(///� 0 7 J Y / sime 1/—/— Date /! tEl Remarks. Block 11: Fuel Gas = 859,597 meet and Assist Gas = 12,245 acct I hereby certify m foregoing is true and correct to the best 04 My Signature L `-- \ tY Royalty Tine Manager, Production Taxes and Ro Note: All volumes must be corrected to pressure of 14.65 psi/. and to a temperature of 60o F. Authority 20 AAC25.235. al Panted Name Bernard W. Han ( ) (/1 ^ �� 07 Hajny Phone 907 564.5026 Dat V 7 Form 10 - 422 Rey. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DI Submit in Duplicate DATE TIME 9/3/2007 1605 -1630 9/10/2007 0550 -0602 9/11/2007 1203 -1226 9/11 /2007 1250 -1320 9/11 /2007 1640-1650 9/11/2007 2000 -2021 9/12/2007 1435 -1440 9/12/2007 1445 -1507 9/12/2007 1450 -1455 9/13/2007 1650 -1700 9/14/2007 1630 -1650 9/14/2007 1650 -1700 9/15/2007 0820 -0830 9/15/2007 0900 -0910 9/18/2007 1450 -1500 9/18/2007 1550 -1600 9/20/2007 2122 -2142 9/23/2007 0351 -0418 9/23/2007 0530 -0553 9/23/2007 0716 -0730 9/26/2007 0739-0756 9/26/2007 2223 -2254 9/27/2007 0210 -0218 9/27/2007 0330 -0347 9/27/2007 1740 -1745 9/27/2007 1807 -1812 9/28/2007 0411 -0416 9/28/2007 0642 -0647 9/28/2007 0700 -0705 9/28/2007 0800 -0805 9/28/2007 0820 -0825 9/28/2007 1000 -1005 9/28/2007 1012 -1017 9/28/2007 2310 -2315 9/29/2007 0001 -0015 TOTAL 3,463 BP EXPLORATION(ALASKA) INC. PRUDHOE BAY UNIT- FS -3 GAS FLARING INCIDENT REPORT September 2007 J Unplanned Events less than or equal to 1 hour 1 - VOLUME DESCRIPTION OF INCIDENT & CAUSE 8 Not required for unplanned events which 75 are less than or equal to 1 hour 7 14 3 7 3 4 4 3 3 3 3 3 3 3 11 11 2 85 2 9 962 1,830 40 40 40 40 40 40 40 40 40 40 5 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour Pape 1 10/16/2007 250 PM DATE 9/13/2007 9/18/2007 9/27/2007 9/28/2007 DATE 9/20/2007 9/26/2007 9/26/2007 9/26/2007 9/27/2007 9/27/2007 9/27/2007 9/28/2007 9/28/2007 9/28/2007 9/28/2007 9/28/2007 9/28/2007 9/28/2007 9/28/2007 9/28/2007 9/28/2007 DATE TIME 1330-1700 1300 -1515 0511 -0630 0343-0445 TOTAL TIME 1615 -1620 0830 -0840 1245 -1250 1745 -1750 0320 -0325 0700 -0705 1545 -1550 0352 -0357 0459 -0504 0507 -0512 1135 -1140 1652 -1657 2034 -2039 2052 -2057 2122 -2127 2217 -2220 2230 -2235 TOTAL TIME TOTAL 0 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT September 2007 f Unplanned Events greater than 1 hour 1 VOLUME DESCRIPTION OF INCIDENT & CAUSE 126 See attachments 1,339 20 14 1,499 'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf J VOLUME DESCRIPTION OF INCIDENT & CAUSE 3 See attachments 240 240 240 60 60 60 60 40 40 40 40 40 40 40 40 40 1,323 ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 1 VOLUME. DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See attachments See attachments Page 2 10/18/2007 2:50 PM TOTAL Unplanned Events c 1 Hour 3.463 Unplanned Events > 1 Hour 1.499 Planned Events c 1 hour and not 1 323 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge - 54,460 Assist 12,245 TOTAL FLARED VOLUME 72,990 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT September 2007 Page 3 10/16/2007 2:50 PM Flare Start Date 9/1/2007 Flare End Date 9/30/2007 FS3 Flare Report Time Of Flaring Report System Date Start Time Stop Time Duration Intermit'nt Bik Smoke Planned Reported By Volume (MSCF) 07 -385 Flare Relief 9/13/2007 1:30:00 PM 5:00:00 PM 1 210 minutes No No No BP1UACKSQHA 126 Determination Cause STV -IP TIC 1801 unloaded due to low gas rates. Action Taken Loaded 1802 STV /IP T /C. 07 -393 Flare Relief 9/18/2007 1:00:00 PM 3:15:00 PM ' 4 135 minutes No No No BP11..IACKSOHA 1339 Determination Cause STV-IP VC 1801 unloaded due to temperature. Action Taken Loaded STV /IP T/C 1801 07-395 Flare Relief 9/20/2007 4 15:00 PM 4.20:00 PM 5 minutes No No Yes BP1 \GARSKEH 3 Determination Cause T/C 1801 put on line and due to low ambient temps and 1802 manually SD due to high hours. Action Taken 1801 loaded. 07 -398 Flare Relief 9/26/2007 8:30:00 AM 8:40:00 AM 10 minutes No No Yes BPI \GARSKEH 240 Determination Cause 1806 AL T/C manually shut down for a water -wash. Action Taken T/C completed depressureing stage. 07 -398 Flare Relief 9/26/2007 12:45:00 PM 12:50:00 PM 5 minutes No No Yes BP1\GARSKEH 240 Determination Cause 1806 Compressor Case depressuring post Cooldown Cranking for scheduled WaterwashNIGV Insp. Normal Compressor Case depressunng. 07-398 Flare Relief 9/26/2007 5:45:00 PM 5:50:00 PM 5 minutes No No Yes BP1 \GARSKEH 240 Determination Cause 1806 Compressor Case depressuring post Spin Dry Cycle from Waterwash. Normal Compressor Case depressuring. Action Taken Action Taken Flare Start Date 9/1/2007 Flare End Date 9/30/2007 FS3 Flare Report Time Of Flaring Report System Date Start Time Stop Time Duration intermit'nt Bik Smoke Planned Reported By Volume (MSCF) 07-400 Flare Relief 9/27/2007 3:20:00 AM 3:25:00 AM 5 mnutes No No Yes BP1 CARVERWJ 60 Determination Cause 1804 T/C normal shutdown in preparation for maintenance. Action Taken Normal shutdown Compressor Case depressuring volume. 07 -400 Flare Relief 9/27/2007 5:11:00 AM 6:30:00 AM \4 79 minutes Yes No No BP1\CARVERWJ 20 Determination Cause 1806 AL Compressor unloaded due to Fieldwide AL System Conditions This caused the AL Compressor gas bad to back into the Residue Gas System which momentarily caused the HP Operational Flare 10 Action Taken activate. Unit was rebaaded and attempted to be optimized for the current AL System Conditions. 07 -400 Flare Relief 9/27/2007 7:00:00 AM 7:05:00 AM 5 minutes No No Yes BP1 \CARVERWJ 60 Determination Cause 1804 T/C normal shutdown post Cooldown Cranking for scheduled maintenance. Action Taken Normal shutdown Compressor Case depressuring volume. 07-400 Flare Relief 9/27/2007 3 :45:00 PM 3:50:00 PM 5 minutes No No Yes 13P1 \CARVERWJ 60 Determination Cause 1804 T/C normal shutdown post waterwash and spin dry cycle. Action Taken Normal shutdown Compressor Case depressuring volume. 07 -401 Flare Relief 9/28/2007 3:43:00 AM 445:00 AM "J 62 minutes No No No BP1\CARVERWJ 14 Determination Cause HP Operational Flare activated due to momentary Residue Gas System pressure anomaly. Residue Gas System stabilized. 07 -401 Ctd'd Slowdown 9/28/2007 3:52:00 AM 3:57:00 AM 5 minutes No No Yes BP1 \CARVERWJ 60 Determination Cause 1803 T/C normal shutdown for scheduled maintenance (Waterwash and VIGV insp). Normal shutdown Compressor Case depressuring volume. Action Taken Action Taken Flare Start Date 9/1/2007 Flare End Date 9/30/2007 FS3 Flare Report Time 01 Flaring Report System Date Start Time Stop Time Duration Intermit'nt Blk Smoke Planned Reported By Volume (MSCF) 07-401 Ctn'd Blowdown 9/28/2007 4:59:00 AM 5:04:00 AM 5 minutes No No Yes BP1 \CARVERWJ 40 Determination Cause 1803 Aborted start when attempting to Crank for Cooldown. Action Taken Normal Compressor Case depressuring volume 07 -401 Cut() Blowdown 9/28/2007 5:07:00 AM 5:12:00 AM 5 minutes No No Yes BPI\CARVERWJ 40 Determination Cause 1803 Aborted start when attempting to Crank for Cooldown. Action Taken Normal Compressor Case depressuring volume. 07 -401 Ctn'd Blowdown 9/28/2007 11:35:00 AM 11:40:00 AM 5 minutes No No Yes BPI\CARVERWJ Determination Cause 1803 Aborted start when attempting to Crank for Cooldown. Action Taken Normal Compressor Case depressuring volume. 07 -401 CUM Blowdown 9/28/2007 4:52:00 PM 4:57:00 PM 5 minutes No No Yes BP1 \CARVERWJ Determination Cause 1803 Aborted start when attempting to Crank to Cooldown and perform troubleshooting maintenance. Action Taken Normal Compressor Case depressurng volume. 07 -401 Cid'd Blowdown 9/28/2007 8:34:00 PM 8:39:00 PM 5 minutes No No Yes BPIICARVERWJ Determination Cause 1803 Normal shutdown post Turbine Waterwashng. Action Taken Normal Compressor Case depressuring volume. 07 - 401 Cm'd Blowdown 9/28/2007 8:52:00 PM 8:57:00 PM 5 minutes No No Yes BP1\CARVERWJ Determination Cause 1803 Aborted start when attempting to Crank for mantenance troubleshooting. Norval Comprssor Case depressuring volume. Action Taken 40 40 40 40 Flare Start Date 9/1/2007 Flare End Date 9/30/2007 FS3 Flare Report Time Of Flaring Report System Date Start Time Stop Time Duration Intermit'nt Blk Smoke Planned Reported By Volume (MSCF) 07-401 Chi Slowdown 9/28/2007 9:22:00 PM 9:27:00 PM 5 minutes No No Yes BP1 \CARVERWJ Determination Cause 1803 Aborted start when attempting to Crank tor maintenance uoubleshooting. Action Taken Normal Compressor Case depressunng volume. 07 -401 Ctd'd Blowdown 9/28/2007 10:17 :00 PM 10:22:00 PM 5 minutes No No Yes BPI\CARVERWJ Determination Cause 1803 Aborted start when attempting to Crank Ior maintenance troubleshooting. Action Taken Normal Compressor Case depressuring volume. 07 -401 Ctn'd Blowdown 9/2812007 10:30:00 PM 10:35:00 PM 5 minutes No No Yes BPI\CARVERWJ Determination Cause 1803 Aborted start when attempting to Crank tor maintenance troubleshooting Action Taken Normal Compressor Case depressunng volume. 40 40 40 McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL @BP.com] Sent: Saturday, September 01, 2007 12:31 PM To: GPB, Prod Opt TL; McMains, Stephen E (DOA) Cc: GPB, Area Mgr Central (GC1 /3/FS3); GPB, FS3 OTL Subject: RE: GPB Gas Flaring Events Forgot to cc you on this. Dwight To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 -793 -1241, fax 907- 276 -7542 From Dwight Warner, GPB Production Optimization Team Leader Flaring events that have recently occurred at GPB An extended flaring event occurred on August 13th when 1806 AL compressor unloaded due to Fieldwide AL system conditions. This caused the AL Compressor gas load to back into the Residue Gas System which temporarily caused the HP Operational Flare to activate. The Unit was reloaded and attempted to be adjusted to Al System operating conditions. Flaring began at 10:20 and ended at 22:45 (745 minutes). Total volume flare was 346 MSCF. This may be a duplicate but I wanted to make sure you had it. Extended flaring event at F53 also on August 13th when 1806 AL compressor unloaded due to Fieldwide AL system conditions. This again caused the compressor gas load back into the Residue Gas System which temporarily caused the HP Operational Flare to activate. The unit was reloaded and attempted to be adjusted to the current AL system conditions at the time. Flaring began at 02:35 and ended at 06:23 (228 minutes). Total volume flared was 115 MSCF. An extended flaring event occurred on August 25th at FS3 during facility shutdown prior to planned TAPS slowdown. 1803 T/C train manually unloading to idle which temporarily caused HP Operational Flare System to exceed it's predetermined set point. Flaring began at 00:38 and ended at 02:57 (139 minutes). Total volume flared was 67 MSCF. Another extended flaring event occurred on August 25th at FS3 during facility shutdown prior to planned TAPS slowdown. 1806 T/C train manually unloading to idle which temporarily caused HP Operational Flare System to exceed it's predetermined set point. Flaring began at 06:35 and ended at 07:50 (75 minutes). Total volume flared was 67 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner /Alternate Hal Tucker GPB Production Optimization TL (907) 659-5566 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL (GPBProdOptTL @BP.com] Sent: Saturday, September 01, 2007 12:29 PM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; GPB, Environ Advisor East; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Area Mgr Central (GC113 /FS3); GPB, FS3 OTL Subject: GPB Gas Flaring Events To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907- 276 -7542 From Dwight Warner, GPB Production Optimization Team Leader Flaring events that have recently occurred at GPB. An extended flaring event occurred at F53 on August 12th when 1806 AL compressor unloaded due to Fieldwide AL system conditions. This caused the AL Compressor gas load to back into the Residue Gas System which temporarily caused the HP Operational Flare to activate. The Unit was reloaded and attempted to be adjusted to Al System operating conditions. Flaring began at 10:22 and ended at 1135 (73 minutes). Total volume flared was 38 MSCF. An additional event also occurred at F53 on August 12th with the some issues as above. Flaring began at 14:42 and ended at 18:10 (208 minutes). Total volume flared was 217 MSCF. 1 appoligize for the late notice but these were only recently recorded in the flare data base. If you require additional information, please don't hesitate to call me. Dwight Warner /Alternate Hal Tucker GPB Production Optimization TL (907) 659-5566 1 McMains, Stephen E (DOA) a From: GPB, Prod Opt TL [GPBProdOptTL@BP.com] Sent: Sunday, September 16, 2007 10:49 AM To: McMains, Stephen E (DOA) Cc: GPB, Prod Opt TL; GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL; GPB, Optimization Engr Subject: GPB Gas Flaring Event To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907- 793 -1241, fax 907- 276 -7542 From: Beverly Luedke -Chan, Field Optimization Engineer - on behalf of Hal Tucker, GPB Production Optimization Team Leader An extended Raring event occurred at FS3 on September 13 at 1:30 pm. Flaring occurred when STV -IP T/C 1801 unexpectedly unloaded due to low gas rates. STV -IP TIC 1802 was loaded up to take its place. Total volume was 129 MSCF. Duration was 210 minutes. If you require additional information, please don't hesitate to call me. Beverly Luedke -Chan GPB Field Optimization Engineer (907) 659-4382 for Hal Tucker GPB Production Optimization TL (907) 659-4472 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL@BP.com] Sent: Thursday, September 20, 2007 6:42 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL Subject: RE: GPB Gas Flaring Event To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907-276-7542 From: Dwight Wamer , GPB Production Optimization Team Leader An extended flaring event occurred at FS3 on September 18. Flaring occurred when STV -IP T/C 1801 unloaded due to temperature. STV -IP TIC 1802 was loaded up to take its place. The event began at 13:00 and ended at 15:15 (135 minutes). Total volume flared was 1339 MSCF. If you require additional information, please don't hesitate to call me. Dwight Wamer GPB Production Optimization TL (907) 659 -5566 McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL @BP.com] Sent: Friday, September 28, 2007 7:59 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB. Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL; GPB, Area Mgr East (FS1 /2 /COTU /Seawater); GPB, FS2 /COTU OTL Subject: GPB Gas Flaring Events To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907 - 276 -7542 From: Dwight Warner , GPB Production Optimization Team Leader An extended flaring event occurred at FS2 on September 27. Flaring occurred while depressuring the 4C /C common lines for removal or the temporary launcher /receiver that had been installed for smart pigging. The event began at 12:40 and ended at 15:40 (180 minutes). Total volume flared was 1220 MSCF. An extended flaring event occurred at FS3 on September 27. Flaring occurred due to 1806 AL compressor unloading due to Fieldwide AL system conditions. This caused the AL compressor gas load to back into the residue gas system which momentarily caused the HP flare to activate. The unit was reloaded and gas lift rates adjusted and optimized to return to more stable conditions. The event began at 05:11 and ended at 06:30 (70 minutes). Total volume flared was 1830 MSCF If you require additional information, please don't hesitate to call me. Dwight Warner GPB Production Optimization TL (907) 659-5566 1 McMains, Stephen E (DOA) From: GPB, Prod Opt IL [GPBProdOptTLQBP.com] Sent: Saturday, September 29, 2007 1:57 PM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL Subject: GPB Gas Flaring Event To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 -793 -1241, fax 907- 276 -7542 From: Dwight Warner , GPB Production Optimization Team Leader An extended flaring event occurred at FS3 on September 28. The HP operational flare activated due to the residue gas system pressure anomaly. The system was stabilize and flaring was stopped. The event began at 03:43 and ended at 04:45 (62 minutes). Total volume flared was 14 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner GPB Production Optimization TL (907) 659-5566 1. 1 Fealty Number I 2 0290000030 JPBU Facility Ndme - iS 3 a Fiek1 A Operator PBU - EOA BP ( 5 Menswear Disposition d October -2007 Disposition Volume MCF 20. For production from multiple pools, list contnbution of each pool as a percent of Total Volume 6. Sold 0 Pool Name Pod Code Percent T Reinjected 0 PRUDHOE 640150 100.00% 9. Flared or vented 1 hour or less 444 9 Flared or vented more than I hour (see fristr ) 0 10 Pea and Purge 38,591 1 1 Used Mr lease operations (specify n Remarks) 990.198 12 Other (see instrucn011f) 0 Official Use OM y Aumomadon>1 hr. $afetY MCF 13. TOTAL VOLUME (ITEMS 6-12) 1,029,233 Lease Use MCF 14 NGL Gas Equivalent 0 Conservation MCF 15. Purchased gas 0 Waste: MCF 16. Transferred thorn CGF 1.028.456 Commissioner Date 17 Transferred to (Express as a negative 5) CGF - 31,444.456 16 Remark. Bkx:k 11 Fuel Gas = 989.865 urea and Assist Gas= 333 aw:l 1 hereby candy that the foregoing is true and correct 10 she best of my knowledge. L Signature t�n,,� e.. -�� – yr me Manager, Production Taxes and Royalty Note: A11 volumes must be corrected to pressure of 14.65 pale and to a temperature of 60o F. Authority 20 AAC25.235. Primed Name Bernard W. Ha)ny Phone (907)564 -5026 Date / a t ( (/ — O-i Form 10 -422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION ED GAS DISPOSITION Submit in Duplicate 1 'Unplanned Events less than or equal to 1 hour VOLUME DESCRIPTION OF INCIDENT & CAUSE 7 Not required for unplanned events which 10 are less than or equal to 1 hour 5 66 18 53 5 3 277 DATE 10/20/2007 10/21/2007 10/25/2007 10/25/2007 10/26/2007 10/26/2007 10/26/2007 10/26/2007 10/26/2007 TIME 0315 - 0325 1 530 540 2226 -2232 2257.2319 0400 -0404 0700 -0716 0718 -0721 0731 -0740 0845 -0915 TOTAL 1 (Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments DATE TOTAL Planned Events Less Than or E DATE TIME TOTAL TIME TOTAL Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour and not exceeding 5.000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pitt Purge Assist TOTAL FLARED VOLUME 444 0 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS -3 GAS FLARING INCIDENT REPORT October 2007 ual 1 Hour AND Not Exceedln ! 5000 Mcf VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments 0 1 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf VOLUME DESCRIPTION OF INCIDENT & CAUSE See attachments 0 TOTAL 444 0 0 0 38,591 333 39 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO ELIMINATE CAUSE See attachments ACTION TAKEN TO EUMINATE CAUSE See attachments Page 1 11/14/2007 2:01 PM 1. Facility Number 0290000030 12. Facility Name PBU FS 3 3. field PBU - EOA 4. Operator BP 5. MoneWw W Disposition November -2007 Disposition Volume MCF / 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume 8. Sold 0 Pool Name Pool Code Percent 7 Reinjected 0 PRUDHOE 640150 100.00% 8 Flared or vented 1 lour or less 473 9 Flared or vented nave than 1 four (sae re ) 2.475 10 Ptol and Purge 37.873 1 11. Used for lease operations (specify in Remarks) 844 309 12. Other (see instructions) 0 ri F.:?., ... • 4111109 . - .. Authorization '' M: Safety Z 4 7S t MCF 13. TOTAL VOLUME (ITEMS 8-12) 885 130 Lease Use MCF 54 NOL Gas Equivalent 0 Conservation MCF 15. Purchased gas 0 Waste MCF 16 lransbne0 from- CGF 876.455 1 �j �j / / -`� G r Date 17 Transferred ID (Express as a negative 0) cGF - 23,029.703 It Remarks. Block I I: Fuel Gas = 838,582 tnscf and Assist Gas = 5,727 mac! I hereby certify that the foregoing is true and cowed to the bast of my knowledge. Signature 4__ _)J Title Manager Production Taxes and Royalty Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Punted Name Bernard W. Hajny Phone (907)564-5028 Date /.-2 — Al - 02 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Form 10 -422 Rev. 1/2004 Submit in Duplicate DATE 1 1/8/2007 11/10/2007 11/13/2007 11/15-16/2007 11/17-18/2007 DATE TIME TOTAL 0 TOTAL Unplanned Events c 1 Houf 390 Unplanned Events > 1 Hour 2,475 Planned Events c 1 hour and not 83 exceeding 5.000 MCF Planned Events > 1 hour or 0 exceeding 5.000 MCF Pilo) Purge 37,873 Assist 5,727 TOTAL FLARED VOLUME 48,548 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-3 GAS FLARING INCIDENT REPORT November 2007 1 'Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 1 1/1 8/2007 0530 0625 330 Not required for unplanned events which 11/19/2007 1547 -1613 7 are less than or equal to 1 hour 11/20/2007 0302 - 0326 7 11/20/2007 1449-1510 5 11/21/2007 2245 -2310 19 11/22/2007 0213 -0230 5 11/22/2007 2153 -2245 17 TOTAL 390 'Unplanned Events greater than 1 hour TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 0001 - 2359 12 See attachments 0001 -2359 4 0001 -2359 9 0553 -2230 2,329 0900 -1604 121 TOTAL 2,475 'Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 11/15/2007 0100-0110 50 See attachments 11/15/2007 0755 - 0815 23 TOTAL 83 ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour 1 ACTION TAKEN TO ELIMINATE CAUSE See attachments 1 ACTION TAKEN TO ELIMINATE CAUSE See attachments 1 'Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See attachments See attachments Pap! 1 12/13/2007 1:38 PM Flare Start Date 11/1/2007 Flare End Date 11/30/2007 Time Of Flaring Report System Date Start Time Stop Time Duration Intermit'nt Blk Smoke Planned Reported By Volume (MSCF) 07-525 Flare Relief 11/8/2007 12:01:00 AM 11:59:00 PM 1438 minutes Yes No No 13P1\MFADJW Determination Cause The HP Operational Flare valve P176V leaked small amount of gas to flare, volume was small enough that it was not observed until volume was seen on meter report at midnight. Action Taken 07-526 Flare Relief 11/10/2007 12:01:00 AM 11 - 00 PM 1438 minutes Yes No No BP1 \MEADJW 4 Determination Cause The HP Operational Flare valve P176V leaked small amount of gas to flare, volume was small enough that it was not observed until vokane was seen on meter report at midnight. Action Taken 07 -527 Flare Relief 11/13/2007 12:01:00 AM 11:59:00 PM 1438 minutes Yes No No BP1\MEADJW Determination Cause The HP Operational Flare valve P176V leaked small amount of gas to flare, volume was small enough that it was not observed until volume was seen «1 meter report at midnight. Inspected valve and found no noticeable problems. Action Taken FS3 Flare Report Inspected valve and could not find any ratifiable problems. Inspected valve and found no notifiable problems. 12 9 Flare Start Date 11/1/2007 Flare End Date 11/30/2007 Repoli System Date Start Time 07 -497 CM'd Blowdwn 11/15/2007 1:00:00 AM 07 -497 Other Time Of Flaring Determination Cause Action Taken 11/15/2007 5:53:00 AM 11:59:00 Determination Cause Action Taken PM 1086 minutes Yes 07 - 497 Card Blowdwn 11/15/2007 7:55:00 AM 8:15.'00 AM 20 minutes Determination Cause Action Taken FS3 Flare Report Stop Time Duration Intermit'nt Blk Smoke Planned 1:10:00 AM 10 minutes No No Yes 1804 T/C normal shutdown for scheduled maintenance (Panel Upgrade, Compressor Bundle Swap, and W HR Tube Map) 1804 T/C Normal shutdown Compressor Case depressuring to Holding pressure. Yes Completed depressors to zero. Reported By BP1 \CARVERWJ No No BP1 \CARVERWJ HP Operational Flare Valve intermittent leakage due to suspected oscillation of P428V Residue Gas System Backpressure Control Valve. Facility is currently operating at abnormally low production rates due to scheduled maintenance on 1804 T/C Tram. Unsuccessfully attempted to stabilize oscillations of P428V Residue Gas System Backpressure Control Valve. Pursuit of problem solving to continue. No Yes 8P1 \CARVERWJ Completed depressure of 1804 compressor to zero pressure for panel upgrade and bundle swap. Volume (MSCF) 60 957 23 Flare Start Date 11/1/2007 Flare End Date 11/30/2007 FS3 Flare Report Time Of Flaring Report System Date Start Time Stop Time Duration Intermit'nt Blk Smoke Planned Reported By Volume (MSCF) 07 -498 Other 11/16/2007 12:01:00 AM 8:30:00 PM 1229 minutes Yes No NO BP1\CARVERWJ Determination Cause HP Operational Flare Valve intermittent leakage due to suspected oscillation of P428V Residue Gas System Backpressure Control Valve. Facility is currently operating at abnormally low production rates due to Action Taken scheduled maintenance on 1804 T/C Train After numerous unsuccessful attempts in rectifying the situation, we were finally successful in making the necessary operational adjustments to eliminate the flare leakage. Although these adjustments may only be a temporary mitigation to the original problem. 07 -501 Other 11/17/2007 9:00:00 AM 11:59:00 PM 899 mklutes Yes No No BP1 \CARVERWJ Determination Cause HP Operational Rare Valve intermittent leakage due to suspected oscilation of P428V Residue Gas System Backpressure Control Valve. Facility is currently operating at abnormally low production rates due to Action Taken scheduled maintenance on 1804 T/C Train. Continuing with operational adjustments in attempt to mitigate leakage. 07 -504 Other 11/18/2007 12:01:00 AM 404:00 PM 983 minutes Yes No No BP1\CARVERWJ Determination Cause HP Operation& Flare intermittent leakage due to suspected oscillations of P428V Residue Gas System Backpressure Control Valve. Facility is currently operating at abnormally low production rates due to Action Taken scheduled maintenance on t804 T/C Train. Continuing with operational adjustments in attempt to mitigate leakage. 1372 33 88 McMains, Stephen E (DOA) From: Sent: To: Cc: Subject: To: Steve McMains, AOGCC steve_mcmainsi@admin.stateak.us 907 -793 -1241, fax 907 - 276 -7542 Dwight Warner GPB Production Optimization TL (907) 659 - 5566/4472 GPB, Prod Opt TL [GPBProdOptTL@BP.com] Saturday, November 17, 2007 6:48 AM McMains, Stephen E (DOA) GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB, Area Mgr Central (GC1 /31FS3); GPB, FS3 OTL GPB Gas Flaring Event From: Dwight Warner, GPB Production Optimization Team Leader Two extended flaring event occurred at FS3 on November 15 and November 16 due to suspected oscillation of P428V Residue Gas System Backpressure Control Valve. The facility is currently operating at reduced rates due to scheduled maintenance on 1804 T/C train. The problem was not resolved on the 15th. Necessary operational adjustments were made to eliminate the flare leakage on the 16th. The first event began on Nov 15 at 0553 and ended at 2330 (1086 minutes). The total volume flared was 1086 MSCF. The second event was the continuation of this event beginning on the Nov 16 at 0001 and ending at 0830 (1229 minutes) The total volume flared was 1372 MSCF. Total volume for both events was 2329 MSCF. If you require additional information, please don't hesitate to call me. 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL ©BP.com] Sent: Wednesday, November 21, 2007 7:07 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL; GPB, Area Mgr East (FS1 /2 /COTU /Seawater); GPB, FS2/COTU OTL Subject: GPB Gas Flaring Events To: Steve McMains, AOGCC steve mcmains@admin.state.ak.us 907 - 793 -1241, fax 907- 276 -7542 From: Dwight Wamer, GPB Production Optimization Team Leader Extended flaring events; On 11/17/07 an extended flaring event occured at FS3 occurred due to the bundle overhaul and panel upgrade maintenance work on LPS 1804. The HP operational flare valve had intermittent leakage due to suspected oscillaton of P428V residual gas system backpressure control valve. The facility is currently operating at lower production rates due to the maintenance on 1804. Operational adjustments continue in order to mitigate leakage. Flaring began at 0900 and ended at 23:59 (899 minutes). The total volume flared was 33 MSCF. On 11/18/07 an extended flaring event occurred at FS2 for partial depressuring of the 16D commonline for thawing procedures. Flaring began at 1005 and ended at 1140 (96 minutes). Total volume flared was 81 MSCF. On 11/18/07 a second extended flaring event occurred at FS2 for partial depressuring of the 16D commonline during fluid de- inventorying process and thawing procedures. Flaring began at 1900 and ended at 2035 (95 minutes). Total volume flared was 65 MSCF. On 11/18/07 an extented flaring event continued at FS3 due to the bundle overhaul and panel upgrade maintenance work on LPS 1804. The HP operational flare valve intermittent leakage due to suspected oscillaton of P428V residual gas system backpressure control valve. The facility is currently operating at lower production rates due to the maintenance on 1804. Operational adjustments continue in order to mitigate leakage. Flaring began at 0001 and ended at 1604 (963 minutes). The total volume flared was 88 MSCF. On 11/19/07 and extened flaring event occurred at FS2 fo? blowing down the 16D commonline to move any accumulated slush. Flaring began at 0929 and ended at 1051 (82 minutes). The total volume flared was 69 MSCF. If you require additional information, please don't hesitate to call me. Dwight Wamer GPB Production Optimization TL (907) 659 - 5566/4472 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL iGPBProdOptTL @BP.com) Sent: Wednesday, November 21, 2007 7:07 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East, GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 011; GPB, Area Mgr East (FS1 /2 /COTU /Seawater); GPB, FS2 /COTU OTL Subject: GPB Gas Flaring Events To: Steve McMains, AOGCC s teve_m cm G i n s@ a d m i n. sta to . a k. u s 907 - 793 -1241, fax 907- 276 -7542 From: Dwight Warner, GPB Production Optimization Team Leader Extended flaring events; On 11/17/07 an extended flaring event occured at FS3 occurred due to the bundle overhaul and panel upgrade maintenance work on LPS 1804. The HP operational flare valve had intermittent leakage due to suspected oscillaton of P428V residual gas system backpressure control valve. The facility is currently operating at lower production rates due to the maintenance on 1804. Operational adjustments continue in order to mitigate leakage. Flaring began at 0900 and ended at 23:59 (899 minutes). The total volume flared was 33 MSCF. On 11/18/07 an extended flaring event occurred at FS2 for partial depressuring of the 16D commonline for thawing procedures. Flaring began at 1005 and ended at 1140 (95 minutes). Total volume flared was 81 MSCF. On 11/18/07 a second extended flaring event occurred at FS2 for partial depressuring of the 16D commonline during fluid de- inventorying process and thawing procedures. Flaring began at 1900 and ended at 2035 (95 minutes). Total volume flared was 65 MSCF. On 11/18/07 an extented flaring event continued at FS3 due to the bundle overhaul and panel upgrade maintenance work on LPS 1804. The HP operational flare valve intermittent leakage due to suspected oscillaton of P428V residual gas system backpressure control valve. The facility is currently operating at lower production rates due to the maintenance on 1804. Operational adjustments continue in order to mitigate leakage. Flaring began at 0001 and ended at 1604 (963 minutes). The total volume flared was 88 MSCF. On 11/19/07 and extened flaring event occurred at FS2 for blowing down the 160 commonline to move any accumulated slush. Flaring began at 0929 and ended at 1051 (82 minutes). The total volume flared was 69 MSCF. If you require additional information, please don't hesitate to call me. Dwight Warner GPB Production Optimization TL (907) 659- 5566/4472 1 1. Facility Number 0290000030 2. FaaMy Name PBU FS 3 3. Field PBU - EOA 14. Operator BP 5. Month/Year al Disposition December -2007 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pod as a percent of Total Volume - 9. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% 8. Flared or vented 1 flour or less 1,871 9 Flared or vented more than 1 flour (see intr.) 811 10. Plot and Purge 37,733 11. Used for lease operations (specify in Remarks) 968,641 ' - . Autnonration >1 hr , 8 aMty ir // MCF 12. Other (see Instructions) 0 13. TOTAL VOtuME(rTEMs 6-12) 1,009,056 lease Use MCF 14. NGL Gas Equivalent 0 Conservation MCF 15. Purchased Oaf 0 Waste. MCF 16. Transferred ham: CGF 998,586 T /�`�/ _ ` //_, y /fo r l - 17. Trmsier ed to: (Express as a negative e) CGF - 28,815,167 19. Remarks Block I l: Fuel Gas = 960,853 msct and Assist Gas = 7,788 ttssct t hereby certify tat the f Is true and coned 10 the best of my knoMedge. Signature The Manager Production Taxes and Royalty Note: All volumes must be corrected to pressure of 14.65 psla and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Bernard W. Hajny Plane (907)564 -5026 Date / Xi Oj Form 10-422 Rev. 1/2004 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Submit in Duplicate 1 !Unplanned Events less than or equal to 1 hour VOLUME DESCRIPTION OF INCIDENT & CAUSE 7 Not required for unplanned events which 40 are less than or equal to 1 hour 40 40 121 368 9 40 565 219 422 1,871 DATE TIME 12/4/2007 0755 -0800 12/4/2007 1023 - 1035 12/4/2007 1351 -1402 12/4/2007 1523 - 1532 12/4/2007 1606 -1636 12/7/2007 1012 -1057 12/8/2007 1917 -1932 12/9/2007 1008 -1018 12/25/2007 0820-0827 12/26/2007 0420 -0429 12/27/2007 1031 -1050 TOTAL 1 !Unplanned Events greater than 1 hour VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 31 See attachments See attachments DATE 12/6/2007 DATE 12/20/2007 TIME 0001 -2359 TOTAL TOTAL TIME 1450-1720 TOTAL 31 BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - FS-3 GAS FLARING INCIDENT REPORT December 2007 1 !Planned Events Less Than or Equal 1 Hour AND Not Exceeding 5000 Mcf DATE - TIME . VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE -,,t-rat ;._,_�..... See attachments 0 780 TOTAL Unplanned Events < 1 Hour 1,871 Unplanned Events > 1 Hour 31 Planned Events < 1 hour and not 0 exceeding 5.000 MCF Planned Events > 1 hour or 780 exceeding 5,000 MCF Pilot Purge ,.•'.' 37,733 Assist 7,788 TOTAL FLARED VOLUME 48,203 See attachments (Planned Events Exceeding 1 Hour OR Exceeding 5000 Mcf 1 VOLUME DESCRIPTION OF INCIDENT d CAUSE 780 See attachments ACTION TAKEN TO ELIMINATE CAUSE Not required for unplanned events which are less than or equal to 1 hour ACTION TAKEN TO ELIMINATE CAUSE See attachments Page 1 1/&2(108 1:41 PM Flare Start Date 12/1)2007 Flare End Date 12/31/2007 FS3 Flare Report Time Of Flaring Report System Date Start Time Stop Time Duration Intermirnt Blk Smoke Planned Reported By Volume (MSCF) 07-532 Flare Relief 12/6/2007 12:01:00 AM 11:59:00 PM 1438 minutes No Determination Cause Ft6AV operational flare valve is leaking by. Action Taken Work request tumed in to repair /rebuild. No No GNP RESLEDK 07 -585 Ctd'd Blowdwn 12/20/2007 2:50:00 PM 5:20:00 PM 150 minutes No No Yes BP1 \CARVERWJ 780 Determination Cause 'A' Train ('A ='C Jumper) brought online post modifications. HP Vessels required warmup to achieve '60F design temperature for normal operating pressure. Maintained lower pressure in HP Vessels Action Taken by directing excess (pressure control) to flare untl adequite warmup was achieved. Completed HP Vessel warmup to enable normal operating pressures. Pressure control returned to normal operating set point. 31 RE: GPB Gas Flaring Event Page 1 of 1 McMains, Stephen E (DOA) From: GPB, Optimization Engr [GPBOptimizationEngr @BP.com] Sent: Wednesday, December 12. 2007 8:36 AM To: McMains Stephen E (DOA) Subject: RE: GPB Gas Flaring Event The first attempt did not go through. Prom: GPB, Optimization Engr Sent: Wednesday, December 12, 2007 8:30 AM To: " steve _mcmainseadmin.state.ak.us' Cc: GPB, Prod Opt TL; GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Envlron Advisor East; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL Subject: GPB Gas Flaring Event To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907-276-7542 From Beverly Luedke -Chan, GPB Field Optimization Engineer for Hal Tucker, GPB Production Optimization Team Leader On 12/06/07 an extended flaring event occurred at FS3. F16AV operational flare valve was discovered to be leaking by. Over the 24 hour period (1438 min) 31 MSCF was flared. A work request was fumed in to repair /rebuild the valve. If you require additional information, please don't hesitate to call me. Beverly Luedke -Chan GPB Field Optimization Engineer, for Hal Tucker GPB Production Optimization TL (907) 659-5566/4472 12/12/2007 GPB Gas Flaring Event Page 1 of 1 McMains, Stephen E (DOA) From: GPB, Prod Opt TL [GPBProdOptTL @BP.com] Sent: Friday, December 21, 2007 11:09 AM To: McMains, Stephen E (DOA) Cc: GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, FS3 OTL; GPB, Optimization Engr Subject: GPB Gas Flaring Event To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907- 276 -7542 From: Dwight Warner, GPB Production Optimization Team Leader On 12/20/07 an extended flaring event occurred at FS3. The event was due to the 'A' Train ('A -'C' Jumper) being brought online post modifications. The HP vessels required warmup to achieve > 60F design temperatures for normal operating pressure. Lower pressure was maintained in the HP Vessels by directing excess (pressure control) to flare until adequate warmup was achieved. Flaring began at 14:50 and ended at 17:20 (150 minutes). Total volume flared was 780 MSCF. Dwight Warner Production Optimizatin Team Leader 907- 659 - 5566/4472 12/21/2007 McMains, Stephen E (DOA) From: Sent: To: Cc: GPB, Prod Opt TL [GPBProdOptTL @BP.com] Wednesday, December 26, 2007 4:25 PM McMains, Stephen E (DOA) GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB, FS3 OTL; GPB, Area Mgr Full Field; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, Area Mgr East (FS1 /2 /COTU /Seawater) Subject: FW: GPB Release Event To: Steve McMains, AOGCC steve_mcmains@admin.state.ak.us 907 - 793 -1241, fax 907 - 276 -7542 From: Hal Tucker, GPB Production Optimization Team Leader As a follow up to the original courtesy notice, I need to restate the potential gas release volume for the 14 -32 event. After speaking to the response team technician that made first entry into the well house, the original volume estimate appears to be significantly over stated, probably by several orders of magnitude. The first responder indicated that he had to place his gas detector within inches of the leak to get an LEL reading. I asked the engineer that made the original calculation to recalculate a worst case value based on moving gas through 2000 feet of .152" ID tubing. Even if the tubing had been completely severed, which it wasn't (turned out to be a thread leak), the worst case volume would be approximately 30 mscf. Given that this was a thread leak, the actual volume (could we have measured it) probably should be measured in scf rather than mscf. My apologies for the confusion. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Production Optimization TL (907) 659 - 5566/4472 From: GPB, Prod Opt TL Sent: Monday, December 24, 2007 4:19 PM To: ' steve _mcmains @admin.state.ak.us' Cc: GPB, Environ TL; Fiedler, Anne M; Benson, Gary A; Pfeiffer, Jim A; Kurz, John; GPB, Environ Advisor East; GPB, FS3 OTL; GPB, Area Mgr Full Field; GPB, Area Mgr Central (GC1 /3 /FS3); GPB, Area Mgr East (FS1 /2 /COTU /Seawater) Subject: GP8 Release Event To: Steve McMains, AOGCC steve_mcmains @admin.state.ak. us 907 - 793 -1241, fax 907- 276 -7542 From: Hal Tucker, GPB Production Optimization Team Leader This is a courtesy notification of an uncontrolled gas release that occurred at well 14 -32 on 12/22/07. The release did not meet any of the reporting thresholds (volume > 1 mm scf or production facility shut down). Only well 14 -32 was required to be shut in and the final, worst case, volume estimate is 900 mscf. If you require additional information, please don't hesitate to call me. Hal Tucker GPB Production Optimization TL (907) 659 - 5566/4472 1