Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutColville River Unit / ConocoPhillipsSTATE OF ALASKA
AOGCC
GAS DISPOSITION FILES
YEAR: 2008
FACILITY: Colville River Unit
OPERATOR: CONOCOPHILLIPS
ConocoPhillips Alaska, Inc.
1280 Plaza Office Building
315 S. Johnstone
Bartlesville, OK 74004
May 20, 2016
TO: Recipients of the Colville River Unit Participating Area Monthly Production
Report of Gas Disposition-REVISED
Enclosed is the Produced Gas Disposition Reports for July 2007 through March 2016.
Please address any questions to Diane Hendrickson at (918) 661-7897.
Sincerely,
Diane Hendrickson
Revenue and Regulatory Analyst
Note: Revisions were due to meter discrepancies and allocations between the Participating
Areas and the tracts. (email). Volumes throughout the 10-422 did not change, only % values in
Box 20 were revised.
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility January-08
Percent
92.8%
6.0%
1.2%
0.0%
100.0%
MCF
19. Remarks:
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 45,368
Pool Name Pool Code
7. Reinjected 3,815,582 ALPINE 120100
FIORD 120120
8. Flared or vented 1 hour or less 2,470 NANUQ 120175
NANUQ-KUPARUK
9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180
OTHER
10. Pilot and Purge 19,088
11. Assist Gas
12. Fuel gas used in lease operations.
504,534
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)4,387,042
Lease Use
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
May 20, 2016
Gas sold to Alpine Transportation Company =
Gas gifted to Village of Nuiqsut =
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date:
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Jan-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
Total Flare > 1 Hour 0
Total Flare <= 1 Hour 2,470
Pilot and Purge 19,088
Total Flare 21,558
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.January-08
Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total
45,368 Volume.
6. Sold Pool Name Pool Code Percent
3,815,582 ALPINE 120100 84.1%
7. Reinjected FIORD 120120 6. 0%
2,470 NANUQ 120175 1. 2%
8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 8. 7%
0 OTHER 0. 0%
9. Flared or vented more than 1 hour (see instr.)
19,088
10. Pilot and Purge
504, 534 100.0%
11. Used for lease. operations (specify in Remarks)
O is al:UseO: Iffin
12. Other (see instructions)
r-Authorization >1 hr:MCFt
t ... EP 4,387,042 Safety
13. TOTAL VOLUME (ITEMS 6 -1
Lease Use
MCF
14. NGL Gas Equivalent FEB 2 0 2008 MCF
Conservation
15. Purchased gas OW 'S. C Waste:MCF
16. Transferred from: eM1y
Commissioner Date
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature 0--S Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
temperature of 60 F. Authority 20
Printed Name Dawn Thomas Phone 263 -4203 Date Z • t S. Zc43.AA C25 735
Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate.
Box 20 revised
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility February-08
Percent
92.4%
6.5%
1.1%
0.0%
100.0%
MCF
19. Remarks:
May 20, 2016
Gas sold to Alpine Transportation Company =
Gas gifted to Village of Nuiqsut =
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date:
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)3,976,704
Lease Use
11. Assist Gas
12. Fuel gas used in lease operations.
466,718
10. Pilot and Purge 16,539
9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180
OTHER
8. Flared or vented 1 hour or less 70 NANUQ 120175
NANUQ-KUPARUK
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 41,554
Pool Name Pool Code
7. Reinjected 3,451,823 ALPINE 120100
FIORD 120120
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Feb-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
Total Flare > 1 Hour 0
Total Flare <= 1 Hour 70
Pilot and Purge 16,539
Total Flare 16,609
Rev 1. 12 May 16
r
STATE OF ALASKA
ALASKA OIL AND` GAS CONSERVATION COMMISSION
FACILITY REPORT Of PRODUCED GAS DISPOSITION
1. Facility Nu mber 2. Facility Name 3; Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC. February-08
Disposition Volume MCF 20. For production from multiple pools, list cortributlon each pool es a percent of Total
41,554 Volume.
6. Sold Pool Name Pooi,Code Percent
3,451,823 ALPINE 120100 82.9%
7. Reinjected FIORD 120120 6. 5%
70 NANUQ 120175 1. 1%
8. Flared or vented 1 hour or:less NANUQ - KUPARUK 120185 9. 5%
0 OTHER 0. 0%
9. Flared or vented more than 1 hour (see instr.).
16,539
10. Pilot and Purge
466, 718 100.0%
11. Used for lease operations (specify in Remarks)
i'''''- t _rye?. -• iic "i•*2= z?+a °._ _ L :_C;fir: ,:! - _ - aY s `.i i9:; j ^ _
e:S "..aJ;,: .;9rs" . =:.v:",'.l- .n.,. -.. .7._,_,F•' :..'._.:- ,t...,..r_. -,.,.. <_ =ei'!:'''t ?1:.ri .,•?:sr_ ,. - ".,tr. , s.. „. _..:.r
12. Other (see instructions)Authorization >1 hr:MCF
3,976,704
Safety
13. TOTAL VOLUME (ITEMS 6 -12) •MCF
Lease Use
14. NGL Gas Equivalent MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:
Commissioner Date
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
temperature of 60 F. Authority 20
Printed Name Dawn Thomas Phone 263 -4203:Date Z.'L S -7. 4.-27: 52 AAC95 93.5
Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Box 20 revised
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Feb -08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
Total Flare 1 Hour 0
Total Flare <= 1 Hour 70
Pilot and Purge 16,539
Total Flare 16,609
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility March-08
Percent
91.2%
8.4%
0.4%
0.0%
100.0%
MCF
19. Remarks:
May 20, 2016
Gas sold to Alpine Transportation Company =
Gas gifted to Village of Nuiqsut =
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date:
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)4,586,851
Lease Use
11. Assist Gas
12. Fuel gas used in lease operations.
507,089
10. Pilot and Purge 19,902
9. Flared or vented more than 1 hour (see instr.)9,100 QANNIK 120180
OTHER
8. Flared or vented 1 hour or less 7,558 NANUQ 120175
NANUQ-KUPARUK
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 46,565
Pool Name Pool Code
7. Reinjected 3,996,637 ALPINE 120100
FIORD 120120
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Mar-08
VOLUME PLANNED
DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
3/25/2008
16:54 - 18:40,
18:48 - 19:59 9,100.00
Electrical/Instrumentation
malfunction;Facility Maintenance UNPLANNED Started / restarted T/C # C-33012; Corrected E&I fluctuation/failure
Total Flare > 1 Hour 9,100
Total Flare <= 1 Hour 7,558
Pilot and Purge 19,902
Total Flare 36,560
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.March -08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
46,565 Volume.
6. Sold Pool Name Pool Code Percent
3,996,637 ALPINE 120100 82.3%
7. Reinjected FIORD 120120 8. 4%
7,558 NANUQ 120175 0. 4%
8. Flared or vented 1 hour or less NANUQ- K.UPARUK 120185 8. 9%
9,100 OTHER 0. 0%
9. Flared or vented more than 1 hour (see instr.)
19,902
10. Pilot and Purge
507, 089 100.0%
11. Used for lease operations (specify in Remarks)
se -
12. Other (see instructions)
L....:. 1ff1C18_,:.:_,.Y''`:. ',,.. .. t !,:
MCFAuthorization >1 hr:
4,586,851
Safety f j • c )f/ 4
13. TOTAL VOLUME (ITEMS 6 -12)MCF
Lease Use
14. NGL Gas Equivalent MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:
1
4 i,41 t 'o f3
Commissioner Date
17.! Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature ILtr Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
temperature of 60 F. Authority 201
Printed Name Dawn Thomas Phone 263 -4203 Date ^ •Ln • Ocs AA C25 215
Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Box 20 revised
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Mar -08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE C
16: 54 - 18: 40,Electrical /Instrumentation
3/25/2008 18: 48 - 19: 59 9,100.00 malfunction;Facility Maintenance UNPLANNED Started / restarted T/C # C- 33012; Corrected E &I fluctuation /failure
Total Flare > 1 Hour 9,100
Total Flare Hour 7,558
Pilot and Purge 19,902
Total Flare 36,560
GAS FLARINC VENTING REPORT - CONOCOPHILL10§ ASKA, INC.
MONTY -:;:'AIR - PERMIT NUMBER c.".:AO041:191N/Piit::::'F'.:r.',1"
GASDISPOSMON
Date of Occurrence: s.:2:20a•ID F ..r2 ve,-e•Tor Oceisirenciii
Ontrildfti Cheek Serectior) .ono 2400 .Minutes
From ;Iiik4 T9:-. 1B:40 II i .',14
Iasi Volume Flared or Yenta*9100. id$6F BBLS:Fn 40:411- To: 1959 01 ill
Planned 0 Unplanned 0 Froin:TO:
rrom:To:
4 OFR :3
By Facility)ToteiblInutos.ftwed or Vented si 02: 57
iiieludes volume flared which generated blielc,srnoke., apglicable)'
A;po.scriptionotIncidont Canso; (Chock arriving ea neededto fully.closcribe Ihn incident)
fOr "PreitteS,4set In
vp SD Iiiiii. iiOn'eiine.ererri;:eiieture Seigolietinillse•
ErncriGENcY.iminDOWN Flerinefor dasito shutdown rstortuo
IC . -. Electrical 1 Instrumentation mollusc-11os Flom tlytdemitaiding
EitessNifinidillchinf inkt.e1W•noteS'iitekalki Fik4lySbutdOwe ow
Fridlitiiininlw:linto ' . .S/13.on
011ier;
Coninenii::: dawn when a Solanditfrailare readied lira loss otconttorof ltioThird eggisieeiicie valve:
O:oLeriOniairen tO.Oicninauioause anelOevenf Recorrannekoh4k and ileSeiibivaaitiotleablei.
k. Scatted I -restarted VC*C..ittoi.2 ..Stabittert ficifiri..pleceas.ar4citr-Wion:
CeiliOies-Osi /train deiresstued 7,Repairedeqegimentilifteulties
Reduced / Increasolinlet gas tales riilli
Coirbililid lore igilitini Facikirrraintanance carripleta.
X derreirled:Ett-fteck*en I fitilige Other:
Comments:. replaced bad.sclentirIorlril siane.recycle valve and-restarted -C43d12.1electInn compre.ssix
C. NartageryantIng :teas:. ( check arta) .
0 , Setalsanifir-ficaiiiinaerOnn. !Oak :upgrades ce testin ,0 . 'arierrieigel4 117 tiliee 6101 ;a9r.p140(
0. iiimate rebrivanL______
Vetitinct Incident
Was the volume over port =O sea: 15 NO: •11 yo. complete term:& Environmental immodlately)
Flare incident-TRUE
Bid iricidthit i4(kelonger.gisii I flour? Yes .0 No 13
111 .tax thiiiiport.te Environmental within 24 booth at KRU; 6594712.brALP at 6T0-450T
Didevont cause black-smoke.> arninutes in 1- lira Storisutkie'mlieilesT Ye's. LI Not . 3
It i•oi;ciiit Eindperneetal Immediately KM-1959424.2'ot ALP 670-42tlidned.fatihis report to Em, at at 670-4507
lillack.staakef.:ereillted from source. .NA enter tag number anddescrijolion)
bakind. Urea of black smoke' -even!:From:NAL To;NA
Voleineflaied Akieb"generated•tilk striolcg":folSOF 861S
Desciiptiedotslapi to rieriiinke inii6slons: (Section LI above)
Maierjaitiered:des: .. c NDLsr •01her: .
Canard Weithen Ale Minim:elm: 2cC Wind Speed:Direction:" 15 MorthEest
Observation by Visible Emission Observer
Based en InforrnaVen..and DOW termed alter reasonable inquirjr,Icertiktharltie statements and•intontaBon in and attached to this
docunientare absete acid complete.
e. 4/:.Z.....,___Faculty :Supervisor. Cato 3 —R 6" -0 g
AI in, Field Envitentran:al'Oempllaneedoerclinaters.ALP44
Kriaarak!' Feld, EnvironnientalCorietiande CeoidiaitoiS. NSIL.- 01
rtooeorActozis 0 IlAlpireOrmunteer;int nau. rim iii *t Viritirtg
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility April-08
Percent
91.6%
8.3%
0.1%
0.0%
100.0%
MCF
19. Remarks:
May 20, 2016
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 44,909
Pool Name Pool Code
7. Reinjected 3,924,347 ALPINE 120100
FIORD 120120
8. Flared or vented 1 hour or less 6,885 NANUQ 120175
NANUQ-KUPARUK
9. Flared or vented more than 1 hour (see instr.)11,354 QANNIK 120180
OTHER
10. Pilot and Purge 18,894
11. Assist Gas
12. Fuel gas used in lease operations.
477,475
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)4,483,864
Lease Use
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
Gas sold to Alpine Transportation Company =
Gas gifted to Village of Nuiqsut =
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date:
Rev 1. 12 May 16
Flaring approved
on original.
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Apr-08
VOLUME PLANNED
DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
4/12/2008 09:53 - 14:15 11,240 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti-surge valve.
4/12/2008 09:38 - 13:33 114 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti-surge valve.
Total Flare > 1 Hour 11,354
Total Flare <= 1 Hour 6,885
Pilot and Purge 18,894
Total Flare 37,133
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.April -08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
B. Sold 44,910 Volume.
Pool Name Pool Code Percent
4,129,647 ALPINE 120100 82.2%7. Reinjected
FIORD 120120 8. 3%
6,885 NANUQ 120175 0. 1%8. Flared or vented 1 hour or less
NANUQ - KUPARUK 120185 9. 4%
11,354 OTHER 0. 0%9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
18,894
11. Used for lease operations (specify in Remarks)
477, 474 100.0%
12. Other (see instructions)E; .... ..
i .0 Authorization >1 hr:MCF
13. TOTAL VOLUME (ITEMS 6 -12)1 a. 4.,J z t W 4,689,164 Safety
MCF ;'
LeaseUsee Cf
14. NGL Gas Equivalent MAY 2 3 2008 MCF
Conservation
15. Purchased gas
Al • , : g G ., Conn. commission Waste:MCF
16. Transferred from:Anchorage t
p
LL / Aft/ . 'G- 0
17. Transferred to: (Express as a negative #)
Commissioner Date
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected toSignature n r, vv Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
temperature of 60 F. Authority 20PrintedNameDawnThomasPhone263 -4203 Date S • Zo - 7...tr6 AAC25 2.35
Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Superseded, save
flaring
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Apr -08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
4/12/ 2008 09: 53 - 14: 15 11,240 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti -surge valve.
4/12/2008 09: 38 - 13: 33 114 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti -surge valve.
Total Flare > 1 Hour 11,354
Total Flare <= 1 Hour 6,885
Pilot and Purge 18,894
Total Flare 37,133
GAS FLARING or VENTING REPORT e CONOCOPHILLIPS ALASKA, INC.
FACILITY - Alpine - -AIR PERMIT NUMBER 488TVP01
GAS DISPOSITION
Date of Occurrence:4/12/ 2008 9 Flare vent Time of Occurrence:
mm/dd/yy)Check Selection)Oa00 24: 00 Minutes
From:09: 53 To: 14: 16 04 :22
Total Volume Flared or Vented:11240 MSCF BBLS From:To:
Planned E Unplanned From:To:
From:To:
Meter No. MTR-35012 By Facility)Total Minutes Flared or Vented 04: 22
Includes volume flared which generated black smoke, if applicable)
A. Description of Incident and Cause: (Check as many as needed to fully describe the incident)
SAD T /C#for Process upset in
T/C SD due to high exhaust temperature section of facility
EMERGENCY SHUTDOWN Flaring fordnlisite shutdown / startup
Electrical/ Instrumentation malfunction Flare system testing
Excesaivelnsuffrdent inlet gas rates into facility Faulty shutdown on
X Facility Maintenance SID on high Vibration
Other.
Comments:
This flare event was a result of taking the HP gas compressor down to repair a problem on the 3rd stage anti-surge valve.
8. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted T/C #Stabilized facility process and operation
Compressor / train depressured Repaired equipment difficulties
Reduced / increased inlet gas rates with
Completed flare testing X Facility maintenance completed
Corrected E &I fluctuation / failure Other.
Comments:
C. Flaring or Venting was: (Check one)
9 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessa to • revent loss of ultimate recov-j
Venting Incident
Was the volume over 1,000 mscf?Yes: 0 No: if Yes, complete form & contact Environmental immediately)
Flare Incident TRUE
Did incident last for longer than 1 hour? Yes 0 No
If Yes, fax this report to Environmental within 24 hours at KRU 659 - 7712 or ALP at 670.4507 i
Did event cause black smoke• > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0
If Yes, contact Enviromental Immediately KRU 659 - 7242 or ALP 670 - 4200 and fax this report to Env at KRU 659 - 7712 or ALP at 670 - 4507
Black smoke' emitted from source:NIA enter tag number and description)Date and time of black smoke' event From:N/A To:N/A
Volume flared which generated black smoke':MSCF BBLS
Description of steps to minimize emissions: (Section B above) Required maintenance completed.
Material flared:Gas:x NGLs:Other:
General Weather:Air Temperature: -6 Wind Speed /Direccfoon: 8 mph East
Observation . Non - Certified Visible Emission Observer
Based on Information and belief formed after reason quiry, I certify that the statements and information in and attached to this
document are true, accurate and cagtplete.
Facility Supervisor Datet .cam J1 /C
cc: Alpine: Field Environmental Compliance Coordinators, ALP -14
Kuparulc Field Environmental Compliance Coordinators, NSK- 81
Printed 41122008 S Drive/Alpine Operations/Forms /Ges Flaring or Venting
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY Alpine AIR PERMIT NUMBER . 489TVP01 • -
GAS DISPOSITION
Date of Occurrence:4/12/ 2008 O Flare vent Time of Occurrence:
mm /ddiyy)Check Selection)00_ 00 24: 00 Minutes
From:09: 38 To: 13: 33 03: 55
Total Volume Flared or Vented:114 MSCF BBLS From:To:
Planned 0 Unplanned From:To:
From:To:
Meter No. MTR -35011 By Facility)Total Minutes Flared or Vented 03: 55
Includes volume flared which generated black smoke, if applicable)
A. Description of Incident and Cause: (Check as many as needed to rutty describe the Incident)
SF) T /C#for Process upset in
T/C SD due to high exhaust temperature section of facility
EMERGENCY SHUTDOWN Flaring for drglsite shutdown / startup
Electrical / Instrumentation malfunction Flare system testing
Excessive/insufficient Inlet gas rates Into facility Faulty shutdown on
X Facility Maintenance S/D on high vibration
Other:
Comments:
This flare event was a result of taking the HP gas compressor down to repair a problem on the 3rd stage anti-surge valve.
B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted T/C #Stabilized facility process and operation
Compressor / train depressured Repaired equipment difficulties
Reduced / increased inlet gas rates with
Completed flare testing x Facility maintenance completed
Corrected E &t fluctuation / failure Other.
Comments:
C. Flaring or Venting was: (Check one)
2 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessary to prevent loss of ultimate recovery _
Venting Incident
Was the volume over 1,000 mscf?Yes: No: El If Yes, complete form & contact Environmental immediately)
Flare Incident TRUE
Did Incident last for longer than 1 hour? Yes El No
If Yes, fax this report to Environmental within 24 hours at KRU- 659 -7712 or ALP at 670 -4507
Did event cause black smoke > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0
if Yes, contact Enviromental immediately KRU 659 -7242 or ALP 670-4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670-4507 j
Black smoke• emitted from source:NIA enter tag number and description)
Date and time of black smoke event From:N/A To:N/A t
Volume flared which generated black smoke':MSCF BBLS
Description of steps to minimize emissions: (Section B above) Required maintenance completed.
Material flared:Gas:x NGLs:Other.i
General Weather.Air Temperature: -6 Wind Speed/Direction: 8 mph East
Observation by Non - Certified Visible Emission Observer
Based on information and belief formed after reasonable • quiry, I certify that the statements and information in and attached to this
document are true, accurate and complete.G//
Facility Supervisor L._I Date he
cc: Alpine: Field Environmental Compliance Coordinators, ALP -14
Kuparuk: Field Environmental Compliance Coordinators, NSK- 61
printed 41122008 S Drive/Alpine Operations/Forms /Gas Flaring or Venting
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility May-08
Percent
90.2%
9.3%
0.5%
0.0%
100.0%
MCF
19. Remarks:
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 48,341
Pool Name Pool Code
7. Reinjected 3,862,256 ALPINE 120100
FIORD 120120
8. Flared or vented 1 hour or less 7,652 NANUQ 120175
NANUQ-KUPARUK
9. Flared or vented more than 1 hour (see instr.)1,783 QANNIK 120180
OTHER
10. Pilot and Purge 17,697
11. Assist Gas
12. Fuel gas used in lease operations.481,181
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)4,418,909
Lease Use
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
Date:May 20, 2016
Gas sold to Alpine Transportation Company =
Gas gifted to Village of Nuiqsut =
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
May-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
5/31/2008 9:23 5/31/2008 21:00 UNPLANNED 1,783 Restarting facility after shutdown Started/restarted T/C # C-33012
Total Flare > 1 Hour 1,783
Total Flare <= 1 Hour 7,652
Pilot and Purge 17,697
Total Flare 27,132
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.May -08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
48,340 Volume.
6. Sold
Pool Name Pool Code Percent
4,174,456 ALPINE 120100 78.7%
7. Reinjected FIORD 120120 9. 0%
7,652 NANUQ 120175 0. 5%
8. Flared or vented 1 hour or less
NANUQ - KUPARUK 120185 11.5%
1,783 OTHER 120120 0. 3%
9. Flared or vented more than 1 hour (see Instr.)
10. Pilot and Purge
17,697
481, 182 -100.0%
11. Used for lease operations (specify in Remarks)
12. Other (see instructions)Authorization >1 hr:MCF
4,731,109 Safety t "
13. TOTAL VOLUME (ITEMS 6 -12)
Lease Use
MCF
14. NGL Gas Equivalent
Conservation
MCF
15. Purchased gas Waste:MCF
16. Transferred from:j[//T" —7 `C 1C>C
Commissioner Date
17. Transferred to: (Express as a negative #)f
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
Z o Z o d temperature of 60 F. Authority 20
Printed Name Dawn Thomas Phone 263 -4203 Date O AAr2R 22/
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Superseded, save
flaring
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
May -08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
5/31/ 2008 19: 23 - 21: 06 1783 Restarting facility after shutdown UNPLANNED Started /restarted T/C # C -33012
Total Flare > 1 Hour 1,783
Total Flare <= 1 Hour 7,652
Pilot and Purge 17,697
Total Flare 27,132
16, .t a ! Pla-u., ./C-k-- /P .
GAS FLARING or VENTING REPORT - CONOCOPHILLIPSALASSA, INC.
FACILITY - Alpine AIR PERMIT NUMBEk.. 489TV.P01
GAS DISPOSITION
Date o II rrence:5/311200B r36are 0 vent Time of Occurrence:
mm/d0/ChOkSeleclion)00: 00 24: 00 Minutes
From:19: 23 TO: 21: 06 • .i- 0:43;
Total Voltirne•Flared or Vented:1783. .MSCF BBLS.Frorn: To:
Planned b Unplanned CI From:To:
Frain:To: •
Meter No„ MTFO5t)12 By Facility)TOtalMinutes Flared or iented 01: 43•
Includes:Our* flared which.oenerated black, srocike; if applicable)
A. pesdriptioiyor Incideritend Cause: (Check as Manrea needed.toltillydescribeithe 'Incident)
SCP for PeriCeSe.6041.1ii
TIC SD due tehign•eihadstlerriperaluM section olfacpty
EMEI4G6ICY SHUTDOWhf.Flailheforddlisiie ShidaeWiti slerhil.
Pies:trice)/ Initiornentation Malfunction Flare :system testing •
Excessivcrinsufficlentintet gas rates into facility'faulty shutdown on
FaciliisiMainienabce
Other: restarting ficillty•after shutdown
Comments:
this Aare:event Occurred While:the.tadllityiniasbeirip restarted after a shutdown. Thithuldoitin eccurred'because.the fire.detection for aortmess.module wasoot while
fireiiistemleSting Was:beitie:performed. When the.maintenance departmentmanuallynionered a iredeleCtion device.In'thls.modOle the olantshut down:
s:Action Taken to.Eiiminate cause and Prevent Recurrence: (Check and applicable)
X Started./.1eStarted TIC # ..C-33012 Stabilized facillty.prOCeSsendoperation
Compressor / train depressured Repaired equipment
ReduCedfincreaSedirilefgaS rates with-
Completed flare testing:FaCilftymaintenance.completed
Correcied..E&I fluctuatidnifillUre•PtilBr:
Comments:
O.:Flaring or.VentingWas:.(ChecIc one)
1: 1 necessary for facility operations repairs, upgrades, *or testing procedures 0 an emergency that threatened life or property.
O . .n ad Os a r y "to pre ii ant rose df-ultiniate'recovery
Venting - Incident
Iii/as:nievolume over 1,000.mscf?Yes: !No: 0 .If Yee,COMPlete fOrmkcOritactEnyininmeidafilireediately)
Flare Incident TRUE
Did ihoiitoriy160,161 longer ttfah •rhour7 Yes 0 6.10 0.
IF Yes,latihie.repOrt to•Erivironmental within 24, hours at KRU- 659:7742.orALP at 6704507
Did event cause black smoke> 3.mintries in 1 hror 6.consecutiyemintites?Yes: 0 No: 9
If Yes, contaCt.Enviromental immediately KRU 6594242.or -ALP 5704200 and.fax this reportio.Env at KRU- 659712 or ALP at 670-4507
Black Stripke'tmitted trim Sciurce:enter-tag number and description)
Date.and time. Of blacksmcike! event:From:To:
Volume Pared black smoke'.MSCF BBLS
eSPrigitinis of steps to minim emissions (SectiOn•El above)
Material flared:Oas:x 1IGLs:Other:
Demerol Weather:Air Temperature: 32 Wind Speed/Direction: 15 mph/SE
tiV'tloil-Dertined VISIble'ErnisSiOnObienier
Based on information and belief formed after-Masenable:iriquItY, I thallha.statements artd:Inforrnatidn.in•and attached to this
document are true; accurate and complete.
Facility Sirpervisor Date
cc:. Alpine: Field Environmental Compliance•Coordinators,ALP-14
Kiiparuk: Field Compliance rdinakirs, NStc
Prinreetrii2008 S DrivelAiPias Opw /Gas flaring or Ventind
4
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility June-08
Percent
90.2%
9.3%
0.5%
0.0%
100.0%
MCF
19. Remarks:
Date:May 20, 2016
Gas sold to Alpine Transportation Company = 37440
Gas gifted to Village of Nuiqsut = 177
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)3,908,620
Lease Use
11. Assist Gas
12. Fuel gas used in lease operations.430,642
10. Pilot and Purge 10,528
9. Flared or vented more than 1 hour (see instr.)4,308 QANNIK 120180
OTHER
8. Flared or vented 1 hour or less 16,187 NANUQ 120175
NANUQ-KUPARUK
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 37,615
Pool Name Pool Code
7. Reinjected 3,409,340 ALPINE 120100
FIORD 120120
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Jun-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
6/17/2008 10:54 6/17/2008 12:32
UNPLANNED 1,524 False fire detection Started/restarted T/C # C-33012; stabilized
facility process and operation
6/17/2008 10:29 6/17/2008 12:02
UNPLANNED 2,273 False fire detection Started/restarted T/C # C-33012; stabilized
facility process and operation
6/7/2008 9:06 6/7/2008 10:37 UNPLANNED 511 Excessive/insufficient inlet gas rates into facility Reduced/increased inlet gas rates
Total Flare > 1 Hour 4,308
Total Flare <= 1 Hour 16,187
Pilot and Purge 10,528
Total Flare 31,023
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.June -08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
37,617 Volume.
6. Sold Pool Name Pool Code Percent
3,678,938 ALPINE 120100 76.1%
7. Reinjected FIORD 120120 8. 9%
16,187 NANUQ 120175 0. 5%
8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 11.7%
4,308 OTHER 120120 0. 4%
9. Flared or vented more than 1 hour (see instr.)OTHER 120185 2. 4%
10,528
10. Pilot and Purge
430, 642 100.0%
11. Used for lease operations (specify in Remarks)
x,a as a rvr
12. Other (see instructions)Authorization >1 . hr:
Safety 3E MCF
4,178,220
13. TOTAL VOLUME (ITEMS 6 -12)MCF
Lease Use
14. NGL Gas Equivalent MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:
Commissioner Date
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
temperature of 60 F. Authority 20
Printed Name Dawn Thomas Phone 263 -4203 Date — 1 • t o g AA r2s 2? 9
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit In Duplicate
Superseded, save
flaring
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Jun -08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
6/17/2008 10: 54 - 12: 32 1,524 False fire detection UNPLANNED Started /restarted T/C # C- 33012; stabilized facility process and operation
6/17/2008 10: 29 - 12: 02 2,273 False fire detection UNPLANNED Started /restarted TIC # C- 33012; stabilized facility process and operation
6/ 7/2008 09: 06 - 10: 37 511 Excessive/insufficient inlet gas rates into fat UNPLANNED Reduced /increased Inlet gas rates
Total Flare > 1 Hour 4,308
Total Flare < =1 Hour 16,187
Pilot and Purge 10,528
Total Flare 31,023
GAS FLARING ENTING REPOR1% CON.00OFHILLIPSAil. ..:•.icA,
A.„..$-?.:
INC:
77"...5 - -;•Yrzztx1foR - 47;m1 - .211 , ..;•M r,-...41,tr:::.sm,7iiimFACILITY:AIR PERMIT NUMEIER:
GAS DISPOSMOW
Datif.bt,OcOnctinier.1311712220 O'FliM.. 0*-it tiiiii ofdeenrcihnet-
terittddlyk)Cheet.SeteeF201 00: 00: - ' ' 24110:PRO?
Fr.OM:ilia T.:c 12ioi 2 01:3'
Total Volume Flared or:Vented:2271.- .14.SCF BLS -From:to:
Planned 0 Unplanned 0 From:To:-
Fni2f:t et. ''
tictee:No: - ..mtg;35v11 By Facility) ' '.intalatIntitea iieiediiiteiittiel iiiiis.
Ii4aitideivirdiuthollarailiAlt ti.gorarkted bli3ektmbke;.ilapplicable):
c. iti*dpcion;litinClitetit 1ind.c.46:iii:Igirik ;iliAaleo.lie
Prins (Odic In
lit &D..00.0,1anh echausitoraperatare R:?!=!lis.c cicilitY'
tidtridtalcYtillitil'aiii Friiiiii iei'drliiileittutdiatiitlirtup,EieCtitat / ImInintenckicarnalinia(liti .Floito*nin vial*
1 Infra gaaluter; it111) WW1,.Falai shadorm on
0.12 0.i. 149 24 10'Mini litgli tignisticiit
X Oihcit: ' FfirdAntiClidn '
Gcmmun6
8,,AeltOninIteeln:ElheInittct Gave* -- .'.',..endfrevinit.Rentiirenitetrlictelt:CaidclOicittia'ati . apillailitetiiSd(roatattrrdT)& iiiii I'M 0 .X rinkaraf*rationCortitanditircesutcd ..ikkip0froil'a4tiliniiin ditlithilliei
Rid uced thibreasad inlet On rates aith
Oarnntatad.ilatOlCiiirii.FaidWritithileritinCiaaciarplotad.dceraited Eitiltintuatiati I/allure ottiOe
orimardei'
C.PleilitgleVentInOwato pick. onto.
tj' aeci for facilliY oPeratonc.: reFeIrs;:unaradeColtestinn : math - yea E1 On Cmergenty that threatened lifiior*opertje
0 - rionessarylo.prevein Intact unimaterecovery
Ventiiiii hiaideiit'
tivii 601 igleii roc ' 0 Ro t' 0 .If Yes ; or:imitate to* & contact EnvIronniorital Immod*Iy)
flare thoident"TRUE
litditic-,:deot InettO1 longer intili:i.1100i? 203 El k6: .t
if file ttigiepo;t toEnainanitionial ivitiski 24 hours at KRU- 859421; OrALI. at 4204502
Didationtadisse-binek smoke` > 3 minutes in 1 tireca.consecielve'mlnuttra?Yea: • 0 NO: 0
twee; contact Exiidramneentimricitlialehr KRU'660-7242 Or ALP 67042004nd fax thin report tiiEnt.unt ISRI.1= is94712 oi At-V at 472-4302
Sack smoke'. emitted from actiroat.anti tag number arid dekerigton)gate :end time Of Otack sdaille. avant From To
Volndetiertid050.0genarcite5 black smoke :543C F BaLS
Piiserftitittit dr - ate2316 artirilmizo Oidevions:',(Scd. inn B above)
Material gated:310 X NUI:C Mei*:
9000.:i'VePOI°rt Air TaMparaturo: .45 Wituf:So.euduclion:10 -mph
Illbeerenticet1410i........... /entail Observer
Based on lidetnialletienit belief renned aiteenanataiikte•Inquity. Iccitiklhat the statamente and information in and attached to thisCinevinemtaittlitio. accurate; and 'aciptele.:
Facillty Siagitrvidor:Date' k / 7 70. is'
cc: -Al inn: Field Environmental Compliance COttlinntois,'ALP447/
10 Pali EnvItentheali COM011ente CoeciOnlitnte. ItSK-'21.
R-raz romit 3 Fla* Gat ReNtrentuds.0. 1.S70:13
41 .....-
i
iGASFLARINGtr( ..;::NTINO REPORT ',.; cpwocoinfiLuPa ..tA., RIC.
OliViAl.W...N., ...f4"4" ' - kOILITY: stalli*AF ... - - , 45,,imo, 4 AIR fitERMIT NUMBER:' 1 ..i :... OfignWia:il'A
GAS SiSPOSMON
Pater otGosermete 3,;t7f1063 -in Rift Oi. itfi Mini ‘Oftectirtioce:
dfoiddify!Chet lc Seledion),: moo
Fred:dim, T. 1232 = oelti
riite:11.ViiktiM FtS5td 60Si:enby);1324 f;r4F astt Frosio To at
Pienned • '0 Ofedaidifil - 0 From.To:. •
From TS;e •
1iel* s tITR 53012 , 'c.",31i Fiffi16til Ofnikilfg4ii,ft 011a
i I :- . , Oilquevesiyblutni'fiamoi won'tienetated blecitersolte, Ifvpilfd
L.Desalption ortoddest ent.dattoof {Omit #$ mator,Is.pcptiest tc infix ,tiijoi*e. *Idonij
0 . 0r
414 to:* efe.efefferifpoisteni -4 : 305 , n rtiOtilf
RAF.R.q.E40"s1:44rPowtt „r*:.•rii piraillsii6 stLitilitini./.**11
Gortridi i Inineffeitsiefiindturisle'”r.;liefitetiffiiiiiiifie
4"Sf.40se,kuiitAirIffiSisr. fidoi fwlifif.retAiderfes."
fieffity Wiirelsore-Siq on 00:04ition
X out fetal:he Gi:ificTsoo -
Coideiteief Thitti4efiefifwee.caiissidisi e s* stiutifsivii,.11dithuidoodarairlid die bStaiscrutpdetedloolo.afrAloirio 'O'rodne inodidelocouid4O Kurartik:
8.:AesailTdisitsplieliiste raiiseeed prevestueffurrencoleScdf andderrsdper oppeceoloy
3iariedifsda41 Ti4,.'"A - •r;-330t2 :X Stiii{giiiffiefidip **it*
6O4piesier)frilifferriairsvid Ntt edlifimentdduci:diei
ReducettKlessed Wet gestates din
Comp*tedisne.tostrig FiOritijiiitle"AfKik'' 32iPPI"* .
COitecti4E313fidietlefi / felt*r:.Mie
Caritteerds:"
Oiioqiciiive.Tig •Yo'i,:OfieiktliNti
1 :i * 411 #* PO'-#.461'Et . eit eniemenOydetdreatered We or Froperty"
0 ideissi4-iariiiiiisi6e Or fdtii A..
Arentifidfnettferft
fide Mode over MOO insert.Yet: 1 : 3 No: . 0:"liTesf.OomPleffi4004 iiiilliftriliktelsii.
Flare Incidents TRUE
Uld looldenttestro fooselden 1 : hotif. Tes .. 0 ilo 0
it irefr,f#04reped talievipseeepUtei within heirs 4
Piti orotF*e b!oot IffiGico"? 3mieitA*4441 1 Oir*ti b Rd: 0
If i'eff,..eoniast etitrorosislat ladiodidetv kin, 042.4:tiir *04044'0i:0d tkiiii6repiiit*EulvdtOU- 658-7712 Or ALP at 6704507.
ill** sR0a':ufrald from amiiin:tentertegos.d* aro "cieesfipiony
ailli:iiiiitt*.ot.t*Comai*:evilit Rom:To
Val'uliki):16'1A4P3siWa,CablablOragt*A94;l',63UF. "33i.3.
biiefgeOtteldiefdize.efolselens: (Section 3 etioVo) Stabitized faatv pressure compressor C-320i2:
MIAOW *oil::: . Gas: ' ' X NGLS:',... : Defer:
00*':' 'AreOhO'!itis-ToinpSfelum 43 F. Wind -SpoodiDir&iiiolV,10 reps
C...13 ,oiiflon Visiblos Ossenter-
aiiirdOinktutagerfas0 b00.4 roasonfdds inedifY,Icedy thettse•sleternerds Aud iromptg,Iott 1, 0 and e#actufd toe
deeve:ient*finf,,eaddideend OSISide1S,
Me & f - 40e -
1
iaci.. tilt §di a AA, " ' r
Ai :::Fi..fteiriritantirtibl ..L - .90: 2 -Oi; 4. 96 ;iiatOotA-ALR:14:-. •
Kiiperidr tiold eii4ron'enenti.OirtipOatiie uSaidlisiteie.:N3R 61
4:01707/024:12FItit,k9ttgi
V - ; lie 1 Aif – r • — — C.:0 r
GAS FLARING or VENTING. REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY: - Alpine AIR PE MIT NUMBER .4S9IV.Pdi.
GAS DISPOSITION.
Date 'of Occurrence:5:72000 2 tle:e Ovrrc Tinto or Occurrence: •
0nmidtFYYt iChs7:.: S=20::tic 0000 74: 0a,minutes
From:0:06 To; 10:3? ' = 01: 31-
Total Volume 'Flared.or Vented:511 1,1577 EiBLB From:
Planned: El Unplanned 0"From To:
Frain,
rowel 140. - 1.tTtiLl5012 I rir Fatality/ToUt Mimes' Flared or Vented in 01: 31
It/l:oludesvciumeflured which generated black smoki,Yapplicabloy
A. oe'sertatIon et Meldeet end CausiE.p)ack es merweseeeded to tollY se SCnt it" InC
S. VC*kV Process asset in
11c sb dim le hoh oriverusetimeresee ulcer of today
EMI.EfiG0,161" S4•4111V31Alt4 flarfrii rat dalsOn ahulthourpsforis;p •
lo:1&• 11./ InskinuontritiOO rthaurclion Faro simtcoilosaog •
X exonatIvOlcoracionl allot per MID DAD focal".Foully 318'41,104n on
Focuw meiettmeiwe ID nil kith vibration-
Other:
Comments:
Al.uppioximalaly 0:00AM Me rectify expononcod a tame allow or riaS rho troarr.k apen)184 boo= seeking -for the Source or the as and slreuttimeousli banter to llienttha kali
4coorrit,...veint. Ti,e, souico or iho gas was evontualtoracui to-n relatively. low rate wart 'on 02 Mat had re.. la production The pus ratiirOnt IttliVoilLpilblriciiitl!
eineuditd Mal horn- Previous Wei terds. Anew well waselse be-mm: triwoht 0nrirte Uyv at%ocoMpli4mMlihe ttioignilootfol.
B. ittlion Takao icif.lholnala Copal, and Provant Tfocsioanca: (Chock and tlasofifie as appfCial0
Blurred / rostaned TIC 4'Sh011ized facility. process Andopuralsm
BOotIllearrot 1 treln dohieesuied Prepared equipment dittlitillies
k Reduced 1 increased Rite! Luis tides
OOmplerc-rfriate losla Facility-maintenance completed
COttecrerl EXI llUctuallon 00;0,0 Other
Comninnle:
C,:Flaririn or.VoltithiguaiL(Ch'eck one)
0 neoesserytorfacility operations, repails.;:uPgrades, or leslioll PrOCelfffa5 an urnerouncy that Mu:atoned' lite or property
ci rieesalyto_prevent loss of uternate iecovelv
Venting Malt:lent.
Was Illo volume over 1 'i000 (140?1 ... 0 tic. 0 til yes complete form & contact Environmental irnmedlitto44
Flare Incident'TRUE
Oiciincident last foi longerthun 1 hour? eA . 2.1 ; , ..)0
II Yes, fax this .rapori to Environmental within 24 hours at•KRU, 6B94711 orAl.P at 570!4507
bid eiant 004 ittaa:sinclie", 3'41h in i hrti S voneecobve mintr.les?r 0 Nu 0
If yes, copied Envinmentailinmontlett lOill 659-7: 24?.. or ALP 610-4200 and *this report co Env at KEU-4494712:or ALP at 4744507
Black Meal** eMilleiti hem SeurOS;era:via:a number and deszriptien)
BataanritTenertd black irpice air! :From To
Vekineriered %Nab generated black smoke"kl,BCF 813LS
1*-0iptien CitittePa to Mink:nice emissiona. (Section B abm'e)
trial tiered:-Pas:x HOW.Other.
4. 0441 . *AirTemperatare. 45 WSosedaDirecrion: 10 mph
Obstsvailein by Nouterldied ViSitile' Emission Crhse,
Based on iirlenit.atien and be mad after te4san : iiaquiry_l *try that tite.-stare.vira ard,infemtatian in and attached totheidecument-are.hue; accurate and Wein
FatilitySuperiiiSor Dates
cc' Alpine: Field Environmental Compliance Cotedir,,etars.Al2,1-1'
Ktiparuk littld En lronmental Comfriarioe Cocitineters. USK- 51'
Pmla. 111.7010 I Cf!...vAlvarm - .7nrc2rwsr...Fortin.q.lax , :1;telvs *r Vs'amil
Y
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility July-08
Percent
89.3%
8.8%
0.6%
1.4%
100.0%
MCF
19. Remarks:
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 46,808
Pool Name Pool Code
7. Reinjected 3,587,390 ALPINE 120100
FIORD 120120
8. Flared or vented 1 hour or less 11,814 NANUQ 120175
NANUQ-KUPARUK
9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180
OTHER
10. Pilot and Purge 14,597
11. Assist Gas
12. Fuel gas used in lease operations.438,375
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)4,098,984
Lease Use
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
Date:May 20, 2016
Gas sold to Alpine Transportation Company = 46017
Gas gifted to Village of Nuiqsut = 791
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Jul-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
Total Flare > 1 Hour 0
Total Flare <= 1 Hour 11,814
Pilot and Purge 14,597
Total Flare 26,411
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.July-08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
46,817 Volume.
6. Sold Pool Name Pool Code Percent
3,883,481 ALPINE 120100 74.4%
7. Reinjected FIORD 120120 8. 4%
11,814 NANUQ 120175 0. 6%
8. Flared or vented 1 hour or less NANUQ-KUPARUK 120185 12.1%
0 QANNIK 120180 1. 4%
9. Flared or vented more than 1 hour (see Instr.)OTHER 3. 1%
14,597
10. Pilot and Purge
438, 376 100.0%
11. Used for tease operations (specify in Remarks)
12. Other (see instructions)Authorization >1 hr MCF
4,395,08 Safety
13. TOTAL VOLUME (ITEMS 6 MCF
Lease Use
14. NGL Gas Equivalent MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:
Commissioner Date
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is t; e an. correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature 4 La tVi Title Supervisor, Revenue & Regulatory pressure of 14. 65 psia and to a
Printed Name Julie Sale Phone 4041/"S5,2 3 Date / I / ZOOP temperature of 60 Authority 20
AAr95 746
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Superseded, save
flaring
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.July-08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold
Pool Name Pool Code Percent
3,883,481 ALPINE 120100 74.4%
7. Reinjected FIORD 120120 8. 4%
8. Flared or vented 1 hour or less
11,814 NANUQ 120175 0. 6%
NANUQ- KUPARUK 120185 12,1%
0 QANNIK 120180 1. 4%
9. Flared or vented more than 1 hour (see Instr.)OTHER 12012[7 0. 4%
14,597 OTHER 120185 2. 8%
10. Pilot and Purge
438, 376 100.0%
11. Used for lease operations (specify In Remarks)
12. Other (see instructions)t;;_:G... r <i% 4f r ..,,..., , ,, , se' !?.Y :a ; ,.:. ; r i3 j is jjl(a} I'.= ;•
Authorization >1 hr:
Safety
MCF +
4,395,085
13. TOTAL VOLUME (ITEMS 6 -12)
MCF
Lease Use
14. NGL Gas Equivalent
Conservation
MCF
15. Purchased gas Waste:MCF
16. Transferred from:
17. Transferred to (Expre i :
Commissioner Date
W4: 18. Remarks:p '
r* rte ::
r tt, e, FrIEfirh
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected toSignaturIA-ZAs Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
temperature of 60 F. Authority 20PrintedNameDawnThomasPhone263 -4203 Date p • 2. 0 •'7a053 AQC2 . 5 2. 3
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility August-08
Percent
88.3%
9.6%
0.8%
1.3%
100.0%
MCF
19. Remarks:
Date:May 20, 2016
Gas sold to Alpine Transportation Company =
Gas gifted to Village of Nuiqsut =
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)2,118,800
Lease Use
11. Assist Gas
12. Fuel gas used in lease operations.267,276
10. Pilot and Purge 17,642
9. Flared or vented more than 1 hour (see instr.)2,084 QANNIK 120180
OTHER
8. Flared or vented 1 hour or less 6,857 NANUQ 120175
NANUQ-KUPARUK
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 23,909
Pool Name Pool Code
7. Reinjected 1,801,032 ALPINE 120100
FIORD 120120
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Aug-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
964
1,120
Total Flare > 1 Hour 2,084
Total Flare <= 1 Hour 6,857
Pilot and Purge 17,642
Total Flare 26,583
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.August -08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
23,910 Volume.
6. Sold Pool Name Pool Code Percent
1,944,832 ALPINE 120100 69.9%
7. Reinjected FIORD 120120'9. 3%
6,657 NANUQ 120175 0. 8%
8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 13.4%
2,084 QANNIK 120180 1. 3%
9. Flared or vented more than 1 hour (see instr.)OTHER 5. 3%
17,642
10. Pilot and Purge
267, 275 100.0%
11. Used for lease operations (specify in Remarks)
12. Other (see instructions)Authorization _1 hr.MCF
2,262,60C Safety 1
13. TOTAL VOLUME (ITEMS 6 -12)
L
1
MCF
Lease Use
14. NGL Gas Equivalent MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:
Commissioner Date
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the for oing is true and corn . to the best of my knowledge.
j Note: All volumes must be corrected to
Signature 14 —Title Supervisor, Revenue & Regulatory pressure of 14. 65 psia and to a
on(g)4G/ 5 ' , 2? Date /t /9 /2G Ar: temperatureof60 Authority 20
Printed Name Julie Sale Ph a95 2g5
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Superseded, save
flaring
CONOCOPHILUPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Aug-08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
8/ 9/2008 10: 58 - 12: 34 963.6 Planned facility maintenance shutdown PLANNED Stabilized facility process and operation
8/22/2008 1:51 - 7:58 1,120 Re- inventory of oil section to prepare for ant PLANNED Re- inventory of the oil section of the facility completed
Total Flare > 1 Hour 2,084
Total Flare < =1 Hour 2,084
Pilot and Purge 17,642
Total Flare 21,810
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY:Alpine AIR PERMIT NUMBER: 489TVP01
GAS DISPOSITION
Date of Occurrence:8/ 9/2008 0 Rare vent Time of Occurrence:
mm/dd/yy)Check Selection)00_ 00 24:OQ lXnutn
From:10: 55 To: 12: 34 a 01: 36
Total Volume Flared or Vented:963.6 MSCF BBLS From:To:
Planned 0 Unplanned From:To
From:To:
Meter No: MTR-36012 By Facility)Total Minutes Flared or Vented a 01: 36
Includes volume flared which generated black smoke, if applicable)
A. Descrtpttan of Incident and Cause: (Check as many as needed to fully describe the Incident)
SID 1/Cie for Process upset in
T/C SD due to high exhaust temperature section of fse7ity
EMERGENCY SHUTDOWN Flaring for details shutdown /startup
Electrical / Instrumentation malfunction Flare system testing
Fxcessive/bnulficient inlet gas rates into facility Faulty shutdown on
X Facility Maintenance SID on high vibration
Other
Comments: This flare event was caused by a planned facility maintenance shutdown.
8. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted T/C S X Stabilized facility process and operation
Compressor / train depassured Repaired equipment di fiadties
Reduced / increased inlet gas rates with
Completed flare testing Facility maintenance completed
Corrected ESi fluctuation / failure Other:
I
Comments:
C. Flaring a: Venting was: (Check one)
0 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessary to prevent loss of ultimate recover
Venting Incident
Was the volume over 1,000 mad?Yes: No: If Yes, complete form & contact Environmental immediately)
Flare Incident TRUE
Did incident last for longer than 1 hour? Yea El No
If Yes, fax this reportto Environmental within 24 hours at KRU- 559 -7712 or ALP at 6704507
Did event cause black smoke• > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0 I
If Yes, contact Erviromental immediately KRU 669.7242 or ALP 670-4200 and fax this report to Env at KRU- 659-7712 or ALP at 670 -4507
Black smoke' emitted from source:enter tag number and description)
Date end lime of black smoke' event From:To:
Volume flared which generated black smoke':MSCF BBLS
Description of steps to minimize emissions: (Section B above)
Material flared:Gas:X NGLs:Other.
General Weather.Air Temperature:Wind Speed/Diredion:
Observation by Non - Certified Visible Emission Observer
Based on information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this
document are true, accurate and complete.
Facility Supervisor Date g---// as.
cc: pine: Field Envuon I Compliance Coordinators, ALP -14
Kuparuk: Field Environmental Compliance Coordinators, NSK- 81
080908 Rare Gas Repel Fan ,cis
8/1112008
I
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY- SAlpme':- UT .;' _ =.AIR PERMIT NUMBER •-489TVP0 . c Y:..
DISPOSITIONGASDIOSI
Date of Occurrence:8l22/2008 Flare vent Time of Occurrence:
mm/dd/yy)Check Selection)00: 00 24130 Minutes I
From:01a51 To: 07:5s 007 I
Total Volume Flared or Vented:1120 MSCF BBLS From:To:I
Planned 9 Unplanned From:To:
From:To:
Meter No. MTR-35012 By Facility)Total Minutes Flared or Vented 05: 07
Includes volume flared which generated black smoke, if applicable)
A. Description of Incident and Cause: (Check as many as needed to fully describe the incident)
SID TRH for Process upset in
T/C SD due to high exhaust temperature section of facility
EMERGENCY SHUTDOWN Flaring forddyste shutdown /startup
Electrical / Inetnanentation malfunction Flare system testing
Excessivedrouf6dent inlet gas rates into facility Faulty shutdown on
X Facility Maintenance S/D on high vibration I
Other.
Comments:
Flaring was required for re- Inventory of the oil section of the facility to prepare for upcoming start up following annual shutdown for maintenance.
ii
Ir
1
a Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted T/C*Stabilized facility process and operation
Compressor I train depressured Repaired equipment difficulties i
Reduced / increased inlet gas rates with
Completed flare testing Facility maintenance completed
Corrected E &I fluctuation 1 failure x Other.I
Comments:
Re-Inventory of the oil section of the facility completed.
i
I
C. Flaring or Venting was: (Check one)j
9 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessary to prevent foss of ultimate recovery
Venting incident
Was the volume over 1,000 mscf?Yes: No: If Yes, complete form & contact Environmental immediately)
Flare Incident TRUE
I
Did incident last for longer than 1 hour? Yes O No
If Yes, fax this report to Environmental within 24 hours at KRU- 659 -7712 or ALP at 670 -4507
Did event cause black smoke' > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0
If Yes, contact Enviromental immediately iCRU 659 -7242 or ALP 670 -4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670 -4507
Black smoke emitted from source:enter tag number and description)j
Date and time of black smoke event From:To: _
Volume flared which generated black smoke:MSCF BBLS
Description of steps to minimize emissions: (Section B above)
Material flared:Gas:X NGLs:Other.
General Weather.Air Temperature: 40 Wind Speed /Direction: 10 mph I
Observation by Non - Certified Visible Emission Observer
Based on information and belief formed after reasonebl • uiry, I certify that the statements and information in and attached to this jdocumentaretrue, accurate and o
G
Facility Supervisor
7' 4 Date 8 / //Z3 /I
cc Alpine: Field Environmental Compliance Coordinators, ALP -14
Kuparuk: Field Environmental Compliance Coordinators, NSK- 81
t
1
i
R pmfet:1 8/22,200e S Olive/Alpine OperadonslFonns /Gas Flaring or Venting
t
s
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility September-08
Percent
88.8%
9.8%
0.7%
0.7%
100.0%
MCF
19. Remarks:
Date:May 20, 2016
Gas sold to Alpine Transportation Company = 48389
Gas gifted to Village of Nuiqsut = 1941
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)3,774,639
Lease Use
11. Assist Gas
12. Fuel gas used in lease operations.450,775
10. Pilot and Purge 12,295
9. Flared or vented more than 1 hour (see instr.)5,425 QANNIK 120180
OTHER
8. Flared or vented 1 hour or less 9,956 NANUQ 120175
NANUQ-KUPARUK
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 50,330
Pool Name Pool Code
7. Reinjected 3,245,858 ALPINE 120100
FIORD 120120
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Sep-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
5,425
Total Flare > 1 Hour 5,425
Total Flare <= 1 Hour 9,956
Pilot and Purge 12,295
Total Flare 27,676
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.August -08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
23,910 i
Volume.
6. Sold Pool Name Pool Code Percent
1,944,832 ALPINE 120100 69.9%
7. Reinjected FIORD i 120120 9. 3%
6,857 NANUQ ;120175 0. 8%
8. Flared or vented 1 hour or less NANUQ- ICUPARUK 120185 13.4%
2,084 QANNIK i 120180 1. 3%
9. Flared or vented more than 1 hour (see Instr.)OTHER 120120 0. 2%
17,642 OTHER 120185 5. 1%
10. Pilot and Purge OTHER i 120100 0. 0%
267, 275 100.0%
11. Used for lease operations (specify in Remarks)
iy is;'% d. aiial: Use;O i'
Instructions)Authorize 1,:,.on >1 ..,.,.::
r; =,. :.:::ii >_ ,.- ..,.,x
12. Other (seelns ti hr.
Safety 2
MCF ilex,13. TOTAL VOLUME (ITEMS 6 -12)
2,262,600 f! y
MCF
Lease Use
14. NGL Gas Equivalent MOF
Conservation
15. Purchased gas Waste:MCF
i it 0 - 2.-
Ilk i Commissioner Date
17. Transferred to (Expre t °
I,
II
18. Remarks:
I hereby certify that the foregoing Is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature Title Supervisor, Production & Re Accounting pressure of 14. 65 psia and to a
temperature of 60 Authority 20
Printed Name Dawn Thomas Phone 263 -4203 Date a• IA . "2_ 0 08 AAr 2A 935
Superseded, save
flaring
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS 1
Aug -08
VOLUME I PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
8/ 9/2008 10: 58 - 12: 34 963.6 Planned facility maintenance shutdown j PLANNED Stabilized facility process and operation
8/22/2008 1:51 - 7:58 1,120 Re- inventory of oil section to prepare for an PLANNED Re- Inventory of the oil section of the facility completed
Total Flare > 1 Hour 2,084
Total Flare < =1 Hour 6,857
Pilot and Purge 17,642
Total Flare 26,583
I I
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACIUTY:Alpine AIR PERMIT NUMBER: 489TVP01
GAS DISPOSITION
Date of Occurrence:8/ 9/2005 OFare Vent Time of Occurrence:
mm/dd/yy)Check Selection)00: 00 24_ 00 Minutes
From:10: 88 To: 12: 34 01: 36
Total Volume Flared or Vented:963.6 MSCF BBLS From:To:
Planned El Unplanned From:To:
From:To:
Meter No: MTR -35012 By Facility)Total Minutes Flared or Vented 01: 36
Includes volume flared which generated black smoke, if applicable)
A. DescripSon of Incident and Cause: (Check as many as needed to fully describe the incident)
SID T10#for Process upset in
T/C SD due to high exhaust temperature section of facility
EMERGENCY SHUTDOWN Flaring for drillsite shutdown / startup
Electrical / Instrumentation malhmdion Flare system testing
Excessive/insufficient inlet gas rates into facility Faulty shutdown on
X Facility Maintenance S/D on high vibration
Other.
Comments: This flare event was caused by a planned facility maintenance shutdown.
B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted T/C #X Stabilized facility process and operation
Compressor / train depressured Repaired equipment difficulties
Reduced / increased inlet gas rates with
Completed flare testing Facility maintenance completed
Corrected E &I fluctuation /- failure --- - - - - --- •- - - - - -- - Oilier. - -
Comments:
C. Flaring or Venting was: (Check one)
El necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessary to prevent loss of ultimate recovery
Ventina Incident
Was the volume over 1,000 mac??Yes: No: If Yes, complete form & contact Environmental immediately)
Flare incident TRUE
Did incident last for longer than 1 hour? Yes 1: 1 No
if Yes, fax this report to Environmental within 24 hours at KRU- 669 -7712 or ALP at 670 -4507
Dld event cause black smoke > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: Q
If Yes, contact Enviromental immediately KRU 659 -7242 or ALP 670-4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670.4507
Black smoke` emitted from source:enter tag number and description)
Date and time of black smoke event From:To:
Volume flared which generated black smoke`:MSCF BBLS
Description of steps to minimize emissions: (Section 6 above)
Material flared:Gas:X NGLs:Other.
General Weather.Alr Temperature:Wind Speed/Direction:
Observation by Non - Certified Vislbte Emission Observer
Based on Information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this
document are true, accurate and
comFacilitySupervisor jW`Date a ( _//_ 498
cc: • pine: Field Env n ntal Compliance Coordinators, ALP-14
Kuparulc Field Environmental Compliance Coordinators, NSK- 61
050908 Flare Gas Report Formals
III
a/1112008
j J /'GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.M
sv '
AIR PERMIT NUMBER s4t39TFACILITY - - Lpne: ?;.*::,+:
GAS DISPOSITION
Date of Occurrence:8/22/ 2008 0 Flare Overt Time of Occurrence:
mm/dd/yy)Check Selection)00 :0Q 24: 00 Minutes
From:01: 51 To: 07: 58 08: 07
Total Volume Flared or Vented:1120 MSCF BBLS From:To
Planned 0 Unplanned From:To:
From:To:
Meter No. MTR -35012 By Facility)Total Minutes Flared or Vented 08: 07
Includes volume flared which generated black smoke, if applicable)
A. Description of Incident and Cause: (Check as many as needed to fully describe the incident)
SID T /C#for Process upset In
TIC SD due to high exhaust temperature section of facility
EMERGENCY SHUTDOWN Flaring for dnlisite shutdown /startup
Elechical / Insuumenlation malfunction Rare system testing
Excessivennsuf0dent Intel gas rates into facility Faulty shutdown on
X Facility Maintenance S/D on high vibratkn
Other.
Comments:
Flaring was required for re- Inventory of the oil section of the facility to prepare for upcoming start up following annual shutdown for maintenance.
8. Acton Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable)
Started / restarted T/C #Stabilized facility process and operation
Compressor/ Lain depressured Repaired equipment difficulties
Reduced / increased inlet gas rates with
Completed flaretesting Facility- maintenance- completed - --
Corrected E&I fluctuation / failure X Other:
Comments:
Re- inventory of the oil section of the facility completed.
C. Flaring or Venting was: (Check one)
El necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessary to prevent loss of ultimate recovery
Venting Incident
Was the volume over 1,000 mscf?Yes: No: if Yes, complete form & contact Environmental Immediately)
Flare Incident TRUE
Did incident last for longer than 1 hour? Yes O No
If Yes, fax this report to Environmental within 24 hours at KRU- 659-7712 or ALP at 670 -4507
Did event cause black smoke > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: O
if Yes, contact Enviromental immediately KRU 659 -7242 or ALP 670.4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670 -4507
Black smoke* emitted from source:enter tag number and description)
Date and time of black smoke* event From:To:
Volume flared which generated black smoke *:MSCF BBLS
Description of steps to minimize emissions: (Section B above)
Material finned:Gas:X NGLs:Other.
General Weather.Air Temperature: 40 Wind Speed/Direction: 10 mph
Observation by Non- Certlled Visible Emission Observer
Based on information and belief formed after reasonabi ulry, I certify that the statements and information in and attached to this
document are true, accurate and 9omplete.
Facility Supervisor Date S`a /
cc: Alpine: Field Environmental Compliance Coordinators, ALP -14
Kuparuk: Field Environmental Compliance Coordinators, NSK- 61
Printed 82212008 S Wive /Alpine Operations/Forms /Gas Flaring or Venting
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility September-08
Percent
88.8%
9.8%
0.7%
0.7%
100.0%
MCF
19. Remarks:
Date:May 20, 2016
Gas sold to Alpine Transportation Company = 48389
Gas gifted to Village of Nuiqsut = 1941
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)3,774,639
Lease Use
11. Assist Gas
12. Fuel gas used in lease operations.450,775
10. Pilot and Purge 12,295
9. Flared or vented more than 1 hour (see instr.)5,425 QANNIK 120180
OTHER
8. Flared or vented 1 hour or less 9,956 NANUQ 120175
NANUQ-KUPARUK
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 50,330
Pool Name Pool Code
7. Reinjected 3,245,858 ALPINE 120100
FIORD 120120
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Sep-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
5,425
Total Flare > 1 Hour 5,425
Total Flare <= 1 Hour 9,956
Pilot and Purge 12,295
Total Flare 27,676
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. MonthNear of Disposition
1 030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.September -08
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
50,348 Volume.
6. Sold Pool Name Pool Code Percent
3,548,540 ALPINE 120100 70.2%
7. Reinjected FIORD 120120 9. 5%
9,956 NANUQ 120175 0. 7%
8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 13.5%
5,425 QANNIK 120180 0. 7%
9. Flared or vented more than 1 hour (see instr.)OTHER 5. 3%
12,295
10. Pilot and Purge
450, 775 100.0%
11. Used for lease operations (specify in Remarks)
12. Other (see instructions)Authorization >1 hr.
Safety sT
MCF
4,077,339
13. TOTAL VOLUME (ITEMS 6 - 12)MCF
Lease Use
14. NGL Gas Equivalent MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:4------m -
Commissioner Date
17. Transferred to: (Express as a negative #)
18.. Remarks:
I hereby certify that the regoing is tru and rrect to the best of my knowledge.
Note: Al! volumes must be corrected to
Signature 1 tic Titie Supervisor, Revenue 8 Regulatory pressure of 14. 65 psis and to a
9 /B)(4/ 3, 5;23Date /if 2 /2&18 temperature of 60 ° F. Authority 20
Printed Name Julie Sale Phone 11Ar95 945
Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Superseded, save
flaring
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Sep-08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
9/16/ 2008 6:35 - 8:13 5,425.00 Instrumental malfunction UNPLANNED Reduced inlet rates; Restarted C -33012
Total Flare > 1 Hour 5,425
Total Flare <= 1 Hour 9,956
Pilot and Purge 12,295
Total Flare 27,676
Sep 17 2008 12:28PM HP LASERJET FAX p.
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.
FACILITY ,-... 1 AIR PERM(T NUMBER n e 7. c:
GAS DISPOSITION
Date of Occurrence: •9118/ 2008 Flare Vert Time of Occurrences
mm/dd/y0 Check Selection)00_ 00 24:0D Minutes
Fran:18: 15 To: 20: 13 01: 38
Total Volume Flared or Vented:5425 MSCF BBLS From:To:
Planned Unplanned O From:To:
From:To: __ _ •
Meter y _M R 35017's =- ? ::(:Qty Feei¢ly) =; .Total Mbytes Flared or Vented 01: 38
Includes volume flared which generated black smoke, if applicable)
A. Dperip8on of Incident and Cause: (Check as marry as needed to fully describe the incident)
SIO T/C:a for Procssa upeel In
TIC SD duets high exhaust lempereture section of fealty
EMERGENCY SHUTDOWN Flaring for dr0isite shutdown /startup
J Electrical 1 Instrumentation malfunction Flare system testing
EzcesaNehnsur(elent inlet gas rotes ttto facility Faulty shutdown on
Faenty Mabtenance WO on high vibration
Other.
Comments:
Faulty temperature probe on 93 bearing of C -33012 caused a turbine shutdown resulting in the flaring of oas.
6. Action Taken to Eliminate Cauca and Prevent Recurrence: ( Cheek and assombe ae applicable)
J Started / restarted T/C 0 C -33012 Stabilized facility process and opera0on
Compressor l train dopreseured Repaired equipment diffiadties
J Reduced 1 Increased Inlet as rates with
COmpletad flare (eating Facility maintenance completed
J Corrected Eat fluctuation /failure Other
Comments:
Reduced Inlet rates, corrected problem ( swapped to spare temperature probe), restarted C- 33012.
C. Flaring or Vending was: (Check one).
El necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessary to prevent loss of ultimate recovery
Venting Incident
Was the volume over 1,000 mscf?Yes: No: 0 If Yee, complete form & contact Environmental immediately)
Flare Incident TRUE
Did Incident last for longer than 1 hour? Yes 0 No
U yea, face this report to Environmental wIdthe 24 hours at KRU- 659-7712 or ALP at 670
Did event cause black smoke* = 3 minutes In 1 hr or 8 consecutive minutes?Yes: .0 No:
it Yee, contact Env •mental Immediately KRU a59 -7242 or ALP 1170. 4200 and fax this report to Env it KRU- 650 -7712 or ALP at 670 -4607
Black smoke' emitted from source:enter tag number and description)
Date and &met t black smoke° event:Front:To:
Volume flared which generated black smoke':MSCF BBLS
Description of step b minimize emissions: (Section B above)
Material flared:Gas:d NGLs:Other.
General Weather Air Temperature 37 F Wind Speed/Direction: 24 mph / East
Observation by Non - Certified Visible Emission Observer
Based on information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this
document are true, accurate and complete.
t / J! ,,/
Facility Supervisor Date 1 ! 7 / f .l
Alpine: Fled Environmental Compliance Coordinators, ALP -14
Kuparuir Field Environmental Comptance Coordinators, NSK- 61
Printed 9(17/2003 9 Drive/Alpine OperatonsiFSrms /Get Flung or Verlrg
e
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3, Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY ColviPe River Unit CONOCOPHILLIPS ALASKA, INC.September-08
Disposition Volume MCF 20. For productkm from multiple pools, fist contribution of each pool as a percent of Total
50, 34:Volume.
6. Sold Pool Name Pool Code Percent
3,548,540 ALPINE 120100 702%
7. Reinjected FIORD 120120 9. 5%
r NANUQ 120175 0_ 7%
8. Flared or vented 1 hour or less NANUQ-KUPARUK 120185
120180 0. 7%
13.5%
9. Flared or vented more than 1 hour (see instr.)11=i QANOTHERKIK 5• 3%
10. Pilot and Purge
12,295
450,77 100.0%
11. Used for lease operations (specify in Remarks)
f.: ; -.r).."*"'";; - '';'''
12 Other (see instructions)Authorization >1 hr MCF 9442Cr26
13. TOTAL VOLUME (IT8VIS 6-12)
Safety4,077,33*
MCF
Lease Use
14. NGL Gas Equivalent MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:472i3i-.441_,... Slee..1 c
17. Transferred to: (Express as a negative #)
Commissioner Date
18. Remarks:
r i'; 41 * IL , 1/ 4
4 ' r )1
t' _ 4.,-- - qi,- ,,, , g''' ' - . !I• t:0'
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
SignaturTitte Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a
temperature of 60 Authority 20
Printed Name Dawn Thomas Phone 263-4203 Date t 0 - t 5 - "?...40G AArPc 916
Form 10422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Sep -08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
9/16/ 2008 6:35 - 8:13 5,425.00 Instrumental malfunction UNPLANNED Reduced inlet rates; Restarted C -33012
Total Flare > 1 Hour 5,425
Total Flare <= 1 Hour 5,425
Pilot and Purge 12,295
Total Flare 23,145
Sep 17 2008 12:28PM HP LASERJET FAX P -2
GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA INC,
M f I tl III {it !.r > 5'i i -
FACILITY,`' ,,n u .AIR PERMIT NUMBER igl
GAS DISPOSITION
Date of Occurrence: 9/16/ 2009 ID Flare vent Time of Occurrence:
mm/dd/yy)Check Selection)OD_00 24: 00 Minutes
From:111:38 To: 20: 13 01: 38
Total Volume Flared or Vented:5425 MSCF BBLS From:To:
Planned Unplanned 0 From:To:
Meter _f4o .: MT 50 .... :Fa
From:To:
R-35 }2 " `i +: ` :!(, By: Faci(l1y) ;..Total Minutes Flared or Vented 01: 38
includes volume flared which generated black smoke, if applicable)
A. Description of incident and Cause: (Check as marry as needed to fully describe the incident)
S/D TIC*for Process upset in
T/C SD due to high exhaust temperature section of fecilty
EMERGENCY SHUTDOWN Flaring for drtlleite shutdown / startup
Electrical 1 instrumentation maaunctton Flare system testing
Excesshre/Insuffele(t iNel gas rates Y1to fadtity Faulty shutdown on
Facility Maintenance SID on high vibration
Other.
Comments'
Faulty temperature probe on #3 bearing of C -33012 caused a turbine shutdown resulting In the flaring of gas.
8. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and desOnibe as applicable)
Started / restarted TIC #C -33012 Stabilized facility process and operation
Compressor 1 train depressu red Repaired equipment difficulties
J Reduced 1 Increased Inlet gas rates with
Completed flare testing Facility maintenance completed
d Corrected Sill fluduat ion /'failure Other:
Comments:
Reduced inlet rates, corrected problem (swapped to spare temperature probe), restarted C- 33012,
C. Flaring or Vending wee: (Cheek one).
0 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property
necessary to prevent loss of ultimate' recovery
Venting Molded
Was the volume over 1,000 mscf9 Yes: 0 No: If Yee, complete form & contact Environmental immediately)
flare Incident TRUE
Did incident last for longer than 1 hour? Yes 0 No
if Yee, flu this report to Environmental within 24 hours at KRU 659 - 7712 or ALP at 870.4507
Old event Gauze black smoke" > 3 minutes In 1 hr' or 6 consecutive minutes?Yes: ,Mo:
ItYes, contact EnvlroritenteJ Immediately KRU 1359 -7242 or ALP 870 -4200 and fax this report to Env at KRU 659 -7712 or ALP at 670 -4607
Black smoke' emitted from source:enter tag number and description)
Date and time of black smoke" event:From:To:
Volume flared which genereteo black smoke':MSCF BBLS
Description of steps to minimize emissions: (Section B above)
Material flared:Gas:4 NGLs:Other.
General Weather Air Temperature:37 F Wind Speed/Direction: 24 mph 1 East
Observation by Non - Certified Visible Emission Observer
Based on information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this
document are true, accurate and complete.
Facility Supervisor Date 9 /17/0
E o Alpine_ Field Environmental Compliance Coordinators, ALP -14
Kuparuk: Field Environmental Compliance Coordinators, NSK. 61
1 Printed 9fl7 2OOe S Drlve/Alpine Operations /Form s /Gas Flaring or Naming
1
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility October-08
Percent
88.9%
9.4%
0.6%
1.0%
100.0%
MCF
19. Remarks:
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 51,954
Pool Name Pool Code
7. Reinjected 3,325,926 ALPINE 120100
FIORD 120120
8. Flared or vented 1 hour or less 3,997 NANUQ 120175
NANUQ-KUPARUK
9. Flared or vented more than 1 hour (see instr.)2,626 QANNIK 120180
OTHER
10. Pilot and Purge 12,353
11. Assist Gas
12. Fuel gas used in lease operations.474,630
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)3,871,486
Lease Use
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
Date:May 20, 2016
Gas sold to Alpine Transportation Company = 47,137
Gas gifted to Village of Nuiqsut = 4,817
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Oct-08
VOLUME PLANNED
DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
10/23/2008 7:03 - 11:22;13:13 - 14:24 2626 Faulty Shutdown UNPLANNED Replaced Quadlog Critical Discrete Module; Restarted C-33012
Total Flare > 1 Hour 2,626
Total Flare <= 1 Hour 3,997
Pilot and Purge 12,353
Total Flare 18,976
Rev 1. 12 May 16
r
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.October -08
Disposition Volume MCF 20. For production from multiple pools. list contribution of each pool as a percent of Total
51,985 Volume.
6. Sold Pool Name Pool Code Percent
3,668,895 ALPINE 120100 68.7%
7. Reinjected FIORD 120120 9. 2%
8. Flared or vented 1 hour or less
3,997 NANUQ 120175 0. 6%
NANUQ- KUPARUK 120185 13.5%
9. Flared or vented more than 1 hour (see Instr.)
2,626
OTHERO
120180 1. 0%
OTHER 6. 9%
12,353
10. Pilot and Purge
474, 630 100.0%
11. Used for lease operations (specify in Remarks)
1 12. Other (see instructions)z ` I`
w, :..::_' '
Authorization >1 hr.MCF
4,214,486 Safety 2 VA4
13. TOTAL VOLUME (ITEMS 6 - 12)
Lease Use
MCF
14. NGL Gas Equivalent
Conservation
MCF
15. Purchased gas Waste:MCF
16. Transferred from:2- - 3 - DT
Commissioner Date
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the oregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected to
Signature fit.fi(, /Title Supervisor, Revenue and Regulatory pressure of 14. 65 psia and to aTr
Printed Name Julie Sale Phone (91 B) 661 -3523 Date 19/ 20,09 temperature of 60 ° F. Authority 20
9A5
Form 10-422 Rev, 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Superseded, save
flaring
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Oct-08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
10/ 23/ 2008 7:03 - 11: 22; 13: 13 - 14: 24 2626 Faulty Shutdown UNPLANNED Replaced Quad log Critical Discrete Module; Restarted C-33012
Total Rare 1 Hour 2,626
Total Flare <0 1 Hour 3,997
Pilot and Purge 12,353
Total Flare 18,976
GAS FLARING or VENTING REPORT - CONOCOPHILLtPS ALASKA, INC.
FACILIT - AWitle AIR PERMIT NUMBER • 489TVPIN
GAS DISPOSRION
Data of Occurrence:10t23i2GO8 CI came Overt 7.100 0j Orarrretree_
krynkidAir)Check Selection)Mg teantts
From:0T:03 To: 1122 04 :19
Total Volume Ftahed or Venial:MO taco'MRS Rom:1343 TO 1444 01: 11
Flaunted Unplanned C7'rrom:to:
FtrattK To:
III Motet No PA7R45O t2 By Facility)Total Npn WuleeRIM orVontvd 06 0
Includes *Donna Mated whidt gonoratod buds smoke, f
ft. Deeenpllon of et and Coate. {Cheat ea rummy es needed to hull{ dmeribei the inddemt
Wit:CB*ono y
tow _ _ /''
y
Pmceet Wool to
wrrww,w•w
TC SD tSoh **oust lotnitotatoto lootilon of fancy
F MT:EMMYS1BJ TC O N nem toe d011sito ottutdoan i Oastop
8lecIrlOP r bottioutoototion maes>nodau flew PirOoarteaiing
Escerteleoinsurikleotireotoos mew Imo fed*x l tnJysta,Mfeaet an oft c rtmeriis
FseG[y A nw SJD on hgh vkuetion
Ulu:r
ConbJ>mrits:
A •t,which i$a.cfiikal - • u, Mae Sa,.,, his 4.;... u. fa .'.Ina..: ace. ahodoo110fthe .Fr i,.A.:u,y_ et •
genetatfonl. The Perim a owed Mstatt of the fitc22 .
8. Mallon Talton to Sladnats Copse cad Prewat Rewumtwx {Glexk And dewuare as applicable)
X Started r rastarled TIC d 043012 {HP lntection Comprsgeor)Stababred fociaty prOcttss ertd Operation
Compressor. l train depresswed Repaired equiptnoittdfIcukdee
ROduuaso t 1M:rested inlet gasy odes itith
Completed flare feeling Facility msdn;eflaraoe a> eJarJ
Corrected Eli fiuchta5r n i failure Odin:
Corrnn *
The Quadrat Crdical Oktcrotes AtocAJle sass replaced to allow the facility to be restarted. The card yea be lent bads to the manufacturer flx etsedysisto determine) if the cause Of
Ma WW1 is lsa tta dt Cancel) he pmeverded in the future The d u ra tion of the 8erin0 was longer then normal Rs a ridgy rest t becrxtaeeite of the e:MinN *vela ba the gas
OPPV#1 /101 open and had tabtrepaired
Fl ar ing
rj inmeteary for away operations. emirs, upgrade& ortessag pmcod ures 0 an emergency gel threatened life or property
0 nem - -, w•ritima a las f E
Vent Ineidaett
Wait the volume over 1,000 atscf2+Yves: No: 0 of Yes. Coy ids form 8 *meet Environmental unedlatoty)
o
Flare Incident TRUE
Oki incident tastier longer men 1 tour? Yea I No 0
If Yes, fax this report to Environmental within 24 hours at mu- ist&rry or ALP at 670-4507
Oki event cause black stroke" a 3 minutes in 1 hr orb constitutive minutes'i> l ?Yes; No Cl
0Yes, ggrod.ggykggigaglimmagiglak K1tI4S9-7242 or ALP 8io• 4ioo and fax this report to Env st MU- GM-TM or ALP:at11Wd807
stack *molts' meted tom source:ender tag number ash deyscrittcn)
Me and tine of black smoke" stank Prom:To:
Velumo hated OM) getwated black smoke=SWF CMS
Dettorkidon of steps to minkn1agt entissions: (Section 8 Ste)
Materiel hared:Oat:X NEL$'.Other:
Genial Wearier:Air 7emperauuse: , IS deo F Whet n: 20 no cut of th a NE
Observation , • Nome i! to Endasron Observer
Bated on k ionhalon and beNet fanned Oar tea t
y
1 CerSfyy shat the sistemenis and Information in end ed ro this
deco mlentafe titre. accurate and
Y9
Facility Supervisor Dade i 6112 -3/ 41 V
4 cc Alm: Reid Endronsneritst comptiancecotarnetora, ALP-f4
Kupaaic.lgeid Environmental Compaance ooeramtatots. WOK- 81
1
rkialr;I 14 re8euat»+? Opezraxxcr:aert3as f1Afi'18 or vcr, ms
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility November-08
Percent
88.0%
9.2%
1.1%
1.7%
100.0%
MCF
19. Remarks:
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20.For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 47,785
Pool Name Pool Code
7. Reinjected 3,185,471 ALPINE 120100
FIORD 120120
8. Flared or vented 1 hour or less 10,252 NANUQ 120175
NANUQ-KUPARUK
9. Flared or vented more than 1 hour (see instr.)11,101 QANNIK 120180
OTHER
10. Pilot and Purge 13,799
11. Assist Gas
12. Fuel gas used in lease operations.477,591
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)3,745,999
Lease Use
Date
MCF
15. NGL Gas Equivalent
Conservation MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
Date:May 20, 2016
Gas sold to Alpine Transportation Company = 42,850
Gas gifted to Village of Nuiqsut = 4,935
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897
Flaring approved
on original.
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Nov-08
VOLUME PLANNED
DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
11/11/2008 7:42 - 14:46 11101 Electrical/ Instrumentation malfunction UNPLANNED Corrected E&I fluctuation/ failure
Total Flare > 1 Hour 11,101
Total Flare <= 1 Hour 10,252
Pilot and Purge 13,799
Total Flare 35,152
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION 1
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2, Facility Name 3. Field 4. Operator 5. Month/Year of Disposition
1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC. i Novem.,e-06
Disposition Volume MCF 20. For production from multiple pools, fist contribution of each pool as a percent of Total
47,811 Volume.
6. Sold Pool Name 1 Pool Code Per 1t
3,6113,146 1tlNE 1 4310 4%'
7. Reinjected FIORD 120,
10,252 NANUQ l'.?.:A751
8. Flared or vented 1 hour or less NANUQ-KUPARUK
11,101 QANNIK
9. Flared or vented more than 1 hour (see Instr.)OTHER
1
10. Pilot and Purge
13,799
1
11. Used for lease operations (specify in Rema
477, 590
i
EffrYIFTK- 1,74,PAP,CliTia
12. Other (see instructions)Authorization >1 hr:
ty Id 0
13. TOTAL VOLUME (ITEMS 6-12)
4,178,699
Safe t
4--IVIIT - i
Lease Use
14. NGL Gas Equivalent IMC,FConservation i
15. Purchased gas 4---- -- - :Waste:i MCF
16. Transferred from:
Commissioner Date i
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the f9rgoing is true a rrect to the best of my knowledge.
1
r Note: All volumes must be corrected tO
Signature J .0 Title Supervisor, Revenue & RequlatorV pressure of 14. 65 psia and to a
temperap ire of 60 Adthor ,:,, 2r
Printed Name Julie Sale Phone (918) 661-3523 Date Lilekdd g AAC 2'
R.
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE
Box's 6, 7, 11 and 20
revised
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Nov-08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
11/ 11/2008 7:42 - 14: 46 11101 Electrical/ Instrumentation malfunction UNPLANNED Corrected E &I fluctuation,' failure
Total Flare > 1 Hour 11,101
Total Flare <= 1 Hour 10,252
Pilot and Purge 13,799
Total Flare 35,152
ft to -: air-( 6
GAS FLARING Or VENTING REPORT - CONOCOPHILUPS ALASKA, INC.
FACILITY - Alpine AIR PERMIT NUMBER . 4897NP01
GAS t7t5PQSIT1t3N
Date of Occurrence:1111112008 ,0 mare Dean Time of Occurrence:
mnNddiyy)Cherie Selecfioh)00: 00 224_00 uasa,ts u
From:07 :42 to: 44; 48 tt irr4I4
Total Volume Flared or Vented it IO1 1 MSCF 6815 From To:
Plowed Unplanned LI Prom:To:
From:To:2.
deter No bait-30012 8y Faclay)Total Mtatdes Flared or Veined m 07x)0
includes volume fared which generated black smoke. If am/matte)J
A Oastrlplion of tnddeM and Cass* (Chock as many as needed to tuft' describe Ma tnetdent)
Sal WI for Prepays !evader
TX SO dug to MO ei4 iI tarrgerstu+o meson of me*
EMERGENCY SHUCDOWN Florin rereb1Hdie ettutdaan $ stash
X Eleceind Jtestnencrtteden rrieltunudrrn Fiero *ste n basting
Exeessiveleadeoltra We* gas rates Into tech y Faulty Shutdown on
Fees, Mainkznface
Other.
t.P en:premier pals was tared durfng the period required to troubleshoot ui problett gavotss t> im tree LP compressor , • being re sher a rp. possible
mechanical, Instrumentation and process issues were mated leading to to discovery of a tailed ktrtd trammeter on the iP_ celtpr car Irani thatwa8 the same of
the restart problems. yeas gas Gem Me LP system rrcm the NP syintem Caused *Wilted texitioeptietmerat hi rite LP eornpmeior. in izd lust phase oftroubleshooting, operators and engineers determined that the LP aompressoe , a surge co n tr o l syste m drag t to t , tel o + rob rg tae yeti pressor to start due to elevated sucpon
p l atsm * . Operators went tuough normal pmCe lees Irt an attempt *lower tho suction mature t!y wniptaa8ng temperatures and preiedare Coeltror8r8. When Maio
eonsprowed llosuocellehd a Second mold Of ttoubieshootio0 Woo required that led to.ON* oe gas blow by end Med lasinsment Scene 04 prvdUCt160 Was •
cuddled lo miairrliae flarir4
B. Action Taken to Etlmtnato Cause and Prevent Rectum= (Cheek mid describe as *Ousels,
Started J restarted T/C S Stohi lzod faddy process snd.operaU0n
Compressor /train deprisaunfd RePaltedequtpmentditl1Cttdea
Reduced /i creased inletgee rates with
Completed tares testing Faetity mabrtenance oomplebsd
x Corroded Edt 4wetration J failure taer:
0121.1
Seetepact the 1 st stage knodtout drams levy a ctni roI to the spare Mod transmater n the result Tire Bed trans l bat rttpaxed or as rttwo9sary.
Adt8onat !dawns and!cr nod matons are being kwrestigated to alertoperators to the tared levet iranersii#er.
C. flaring or Venting was; (Check ono)
E1 necessary *r facility operations. repairs. upgrades. or testing procedures ors emergency meat threatened ate or properly
neeassar' a prevent lass of u twnae reoav7
Venting. Incident
was the volume over 1,000 mscf?Yes: 0 No: If Yes, complete loran A .contact Environmental immediately)
Flare Incident TRUE i
Did bxfdant last for longer atan 1 hour? Yes []No
If Yes, tai t1de report to Environmental within 2+ hours at KRU- 859.7702 or ALP et 670 -4507
Did truant Onset black smoke' > 9 minutes In 1 hr et 0 censedutive alkalies?Ys5 fl No: El
If Yes. AgilfgetraltkidlitALLIWOOMMtgly KJIU 859 -7242 or ALP 670-4200 and fax ibis report to Env at KRU- 659.7712 or ALP at 070
Blackamoke" exnitkad rrore source;enter lag number and description)
Oa and Sete of black dinette* event From 7o:
Volta* flared which generated hiss* mocha':MSCF 8BLS
Desidipuon orsteps a minimize emissions: (Section B above)
Material awed:Gas:x Neu:Other
General Weather:Air /my perahro :.15 deq F Mind Seeed/Dresden: 27 mph out otttfe NE
Obsetva8on by Afcrl:Certrfled Visible Emission Observer
Based on Information ertd belief formed akar reasonaaxt heir! d -:: :ay mra: the statements and infemtmtien in and attached to this
docurront aro hue, accurate and. - e.
Facility Sup 7,,.,,Data rJ
cc: Alpine: Field Environmental Comptlonoe Coordmatois, ALP -14
i' .'
KlrpanjY: REM Environmental ComplianceCoexdnators. NSI(- 61
Prxaditit2109a srdrcuei -ip isoftisdla ct;MO'- !G.: Ftu'r , ,,^
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
2. Facility Name
1030000017 Colville River Unit Processing Facility December-08
Percent
87.7%
8.9%
1.0%
2.3%
100.0%
MCF
19. Remarks:
May 20, 2016
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition
Colville River Unit CONOCOPHILLIPS ALASKA, INC.
Disposition Volume MCF 20.For production from multiple pools, list contribution of each pool as a percent of Total
Volume.
6. Sold 49,576
Pool Name Pool Code
7. Reinjected 3,285,809 ALPINE 120100
FIORD 120120
8. Flared or vented 1 hour or less 3,926 NANUQ 120175
NANUQ-KUPARUK
9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180
OTHER
10. Pilot and Purge 13,365
11. Assist Gas
12. Fuel gas used in lease operations.
489,802
13. Other (see instructions)Official Use Only
Authorization >1 hr:Safety MCF
14. TOTAL VOLUME (ITEMS 6-13)3,842,478
Lease Use
Date
MCF
15. NGL Gas Equivalent MCF
16. Purchased gas Waste:
17. Transferred from:
18. Transferred to: (Express as a negative #)Commissioner
Gas sold to Alpine Transportation Company = 44,246
Gas gifted to Village of Nuiqsut = 5,330
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature:Title:Revenue & Regulatory Analyst
Note: All volumes must be corrected to
pressure of 14.65 psia and to a
temperature of 60 o F. Authority 20
AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date:
Rev 1. 12 May 16
CONOCOPHILLIPS ALASKA, INC
CONSERVATION ORDER NO. 443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Dec-08
START END PLANNED VOLUME
DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME
Total Flare > 1 Hour 0
Total Flare <= 1 Hour 3,926
Pilot and Purge 13,365
Total Flare 17,291
Rev 1. 12 May 16
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 2. Facility Name 3. Field 4. Operator Month/Year of Disposition
1030000017,ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC. 15.December -08
Disposition Volume MCF 20. For production from multiple pools, list conbibution of each pool as a percent of Total
6. Sold 49,607 Volume.
Pool Name Pool Code Percent
3,871,780 ALPINE 120100 66.0%7. Reinjected FIORD 120120 8. 9%
3,926 NANUQ 120175 1. 0%8. Flared or vented 1 hour or less
NANUQ- KUPARUK 120185 13.8%
0 QANNIK 120180 2. 3%9. Flared or vented more than 1 hour (see Instr.)OTHER 8. 0%
10. Pilot and Purge 13,365
489, 802 100.0%
11. Used for lease operations (specify in Remarks)
12. Other (see instructions)Authorization >1 hr :
ty MCFSafe4,428,48C13. TOTAL VOLUME (ITEMS 6 -12)
MCF
Lease Use
14. NGL Gas Equivalent
MCF
Conservation
15. Purchased gas Waste:MCF
16. Transferred from:
17. Transferred to: (Express as a negative #)
Commissioner Date
18. Remarks:
I hereby certify that the fo . oing is true and co to the best of my knowledge.
Note: All volumes must be corrected to
Signature a Title Supervisor, Revenue & Repulatory pressure of 14. 65 psia and to a
temperature of 60 Authority 20PrintedNameJulieSalePhone (918) 661 -3523 Date h* 1c2 AO AA(175 2:4q
Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
SUPERSEDED
CONOCOPHILLIPS ALASKA, INC,
CONSERVATION ORDER NO.443
ALPINE
ALPINE PROCESSING FACILITY
GAS FLARING INCIDENTS
Dec-08
VOLUME PLANNED
DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE
Total Flare > 1 Hour 0
Total Flare <5 1 Hour 3,926
Pilot and Purge 13,365
Total Flare 17,291
SUPERSEDED