Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutColville River Unit / ConocoPhillipsSTATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2008 FACILITY: Colville River Unit OPERATOR: CONOCOPHILLIPS ConocoPhillips Alaska, Inc. 1280 Plaza Office Building 315 S. Johnstone Bartlesville, OK 74004 May 20, 2016 TO: Recipients of the Colville River Unit Participating Area Monthly Production Report of Gas Disposition-REVISED Enclosed is the Produced Gas Disposition Reports for July 2007 through March 2016. Please address any questions to Diane Hendrickson at (918) 661-7897. Sincerely, Diane Hendrickson Revenue and Regulatory Analyst Note: Revisions were due to meter discrepancies and allocations between the Participating Areas and the tracts. (email). Volumes throughout the 10-422 did not change, only % values in Box 20 were revised. Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility January-08 Percent 92.8% 6.0% 1.2% 0.0% 100.0% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 45,368 Pool Name Pool Code 7. Reinjected 3,815,582 ALPINE 120100 FIORD 120120 8. Flared or vented 1 hour or less 2,470 NANUQ 120175 NANUQ-KUPARUK 9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180 OTHER 10. Pilot and Purge 19,088 11. Assist Gas 12. Fuel gas used in lease operations. 504,534 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)4,387,042 Lease Use Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner May 20, 2016 Gas sold to Alpine Transportation Company = Gas gifted to Village of Nuiqsut = I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date: Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Jan-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME Total Flare > 1 Hour 0 Total Flare <= 1 Hour 2,470 Pilot and Purge 19,088 Total Flare 21,558 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.January-08 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total 45,368 Volume. 6. Sold Pool Name Pool Code Percent 3,815,582 ALPINE 120100 84.1% 7. Reinjected FIORD 120120 6. 0% 2,470 NANUQ 120175 1. 2% 8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 8. 7% 0 OTHER 0. 0% 9. Flared or vented more than 1 hour (see instr.) 19,088 10. Pilot and Purge 504, 534 100.0% 11. Used for lease. operations (specify in Remarks) O is al:UseO: Iffin 12. Other (see instructions) r-Authorization >1 hr:MCFt t ... EP 4,387,042 Safety 13. TOTAL VOLUME (ITEMS 6 -1 Lease Use MCF 14. NGL Gas Equivalent FEB 2 0 2008 MCF Conservation 15. Purchased gas OW 'S. C Waste:MCF 16. Transferred from: eM1y Commissioner Date 17. Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to Signature 0--S Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a temperature of 60 F. Authority 20 Printed Name Dawn Thomas Phone 263 -4203 Date Z • t S. Zc43.AA C25 735 Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate. Box 20 revised Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility February-08 Percent 92.4% 6.5% 1.1% 0.0% 100.0% MCF 19. Remarks: May 20, 2016 Gas sold to Alpine Transportation Company = Gas gifted to Village of Nuiqsut = I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date: Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)3,976,704 Lease Use 11. Assist Gas 12. Fuel gas used in lease operations. 466,718 10. Pilot and Purge 16,539 9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180 OTHER 8. Flared or vented 1 hour or less 70 NANUQ 120175 NANUQ-KUPARUK Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 41,554 Pool Name Pool Code 7. Reinjected 3,451,823 ALPINE 120100 FIORD 120120 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Feb-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME Total Flare > 1 Hour 0 Total Flare <= 1 Hour 70 Pilot and Purge 16,539 Total Flare 16,609 Rev 1. 12 May 16 r STATE OF ALASKA ALASKA OIL AND` GAS CONSERVATION COMMISSION FACILITY REPORT Of PRODUCED GAS DISPOSITION 1. Facility Nu mber 2. Facility Name 3; Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC. February-08 Disposition Volume MCF 20. For production from multiple pools, list cortributlon each pool es a percent of Total 41,554 Volume. 6. Sold Pool Name Pooi,Code Percent 3,451,823 ALPINE 120100 82.9% 7. Reinjected FIORD 120120 6. 5% 70 NANUQ 120175 1. 1% 8. Flared or vented 1 hour or:less NANUQ - KUPARUK 120185 9. 5% 0 OTHER 0. 0% 9. Flared or vented more than 1 hour (see instr.). 16,539 10. Pilot and Purge 466, 718 100.0% 11. Used for lease operations (specify in Remarks) i'''''- t _rye?. -• iic "i•*2= z?+a °._ _ L :_C;fir: ,:! - _ - aY s `.i i9:; j ^ _ e:S "..aJ;,: .;9rs" . =:.v:",'.l- .n.,. -.. .7._,_,F•' :..'._.:- ,t...,..r_. -,.,.. <_ =ei'!:'''t ?1:.ri .,•?:sr_ ,. - ".,tr. , s.. „. _..:.r 12. Other (see instructions)Authorization >1 hr:MCF 3,976,704 Safety 13. TOTAL VOLUME (ITEMS 6 -12) •MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from: Commissioner Date 17. Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to Signature Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a temperature of 60 F. Authority 20 Printed Name Dawn Thomas Phone 263 -4203:Date Z.'L S -7. 4.-27: 52 AAC95 93.5 Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Box 20 revised CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Feb -08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE Total Flare 1 Hour 0 Total Flare <= 1 Hour 70 Pilot and Purge 16,539 Total Flare 16,609 Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility March-08 Percent 91.2% 8.4% 0.4% 0.0% 100.0% MCF 19. Remarks: May 20, 2016 Gas sold to Alpine Transportation Company = Gas gifted to Village of Nuiqsut = I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date: Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)4,586,851 Lease Use 11. Assist Gas 12. Fuel gas used in lease operations. 507,089 10. Pilot and Purge 19,902 9. Flared or vented more than 1 hour (see instr.)9,100 QANNIK 120180 OTHER 8. Flared or vented 1 hour or less 7,558 NANUQ 120175 NANUQ-KUPARUK Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 46,565 Pool Name Pool Code 7. Reinjected 3,996,637 ALPINE 120100 FIORD 120120 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Mar-08 VOLUME PLANNED DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 3/25/2008 16:54 - 18:40, 18:48 - 19:59 9,100.00 Electrical/Instrumentation malfunction;Facility Maintenance UNPLANNED Started / restarted T/C # C-33012; Corrected E&I fluctuation/failure Total Flare > 1 Hour 9,100 Total Flare <= 1 Hour 7,558 Pilot and Purge 19,902 Total Flare 36,560 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.March -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total 46,565 Volume. 6. Sold Pool Name Pool Code Percent 3,996,637 ALPINE 120100 82.3% 7. Reinjected FIORD 120120 8. 4% 7,558 NANUQ 120175 0. 4% 8. Flared or vented 1 hour or less NANUQ- K.UPARUK 120185 8. 9% 9,100 OTHER 0. 0% 9. Flared or vented more than 1 hour (see instr.) 19,902 10. Pilot and Purge 507, 089 100.0% 11. Used for lease operations (specify in Remarks) se - 12. Other (see instructions) L....:. 1ff1C18_,:.:_,.Y''`:. ',,.. .. t !,: MCFAuthorization >1 hr: 4,586,851 Safety f j • c )f/ 4 13. TOTAL VOLUME (ITEMS 6 -12)MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from: 1 4 i,41 t 'o f3 Commissioner Date 17.! Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to Signature ILtr Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a temperature of 60 F. Authority 201 Printed Name Dawn Thomas Phone 263 -4203 Date ^ •Ln • Ocs AA C25 215 Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Box 20 revised CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Mar -08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE C 16: 54 - 18: 40,Electrical /Instrumentation 3/25/2008 18: 48 - 19: 59 9,100.00 malfunction;Facility Maintenance UNPLANNED Started / restarted T/C # C- 33012; Corrected E &I fluctuation /failure Total Flare > 1 Hour 9,100 Total Flare Hour 7,558 Pilot and Purge 19,902 Total Flare 36,560 GAS FLARINC VENTING REPORT - CONOCOPHILL10§ ASKA, INC. MONTY -:;:'AIR - PERMIT NUMBER c.".:AO041:191N/Piit::::'F'.:r.',1" GASDISPOSMON Date of Occurrence: s.:2:20a•ID F ..r2 ve,-e•Tor Oceisirenciii Ontrildfti Cheek Serectior) .ono 2400 .Minutes From ;Iiik4 T9:-. 1B:40 II i .',14 Iasi Volume Flared or Yenta*9100. id$6F BBLS:Fn 40:411- To: 1959 01 ill Planned 0 Unplanned 0 Froin:TO: rrom:To: 4 OFR :3 By Facility)ToteiblInutos.ftwed or Vented si 02: 57 iiieludes volume flared which generated blielc,srnoke., apglicable)' A;po.scriptionotIncidont Canso; (Chock arriving ea neededto fully.closcribe Ihn incident) fOr "PreitteS,4set In vp SD Iiiiii. iiOn'eiine.ererri;:eiieture Seigolietinillse• ErncriGENcY.iminDOWN Flerinefor dasito shutdown rstortuo IC . -. Electrical 1 Instrumentation mollusc-11os Flom tlytdemitaiding EitessNifinidillchinf inkt.e1W•noteS'iitekalki Fik4lySbutdOwe ow Fridlitiiininlw:linto ' . .S/13.on 011ier; Coninenii::: dawn when a Solanditfrailare readied lira loss otconttorof ltioThird eggisieeiicie valve: O:oLeriOniairen tO.Oicninauioause anelOevenf Recorrannekoh4k and ileSeiibivaaitiotleablei. k. Scatted I -restarted VC*C..ittoi.2 ..Stabittert ficifiri..pleceas.ar4citr-Wion: CeiliOies-Osi /train deiresstued 7,Repairedeqegimentilifteulties Reduced / Increasolinlet gas tales riilli Coirbililid lore igilitini Facikirrraintanance carripleta. X derreirled:Ett-fteck*en I fitilige Other: Comments:. replaced bad.sclentirIorlril siane.recycle valve and-restarted -C43d12.1electInn compre.ssix C. NartageryantIng :teas:. ( check arta) . 0 , Setalsanifir-ficaiiiinaerOnn. !Oak :upgrades ce testin ,0 . 'arierrieigel4 117 tiliee 6101 ;a9r.p140( 0. iiimate rebrivanL______ Vetitinct Incident Was the volume over port =O sea: 15 NO: •11 yo. complete term:& Environmental immodlately) Flare incident-TRUE Bid iricidthit i4(kelonger.gisii I flour? Yes .0 No 13 111 .tax thiiiiport.te Environmental within 24 booth at KRU; 6594712.brALP at 6T0-450T Didevont cause black-smoke.> arninutes in 1- lira Storisutkie'mlieilesT Ye's. LI Not . 3 It i•oi;ciiit Eindperneetal Immediately KM-1959424.2'ot ALP 670-42tlidned.fatihis report to Em, at at 670-4507 lillack.staakef.:ereillted from source. .NA enter tag number anddescrijolion) bakind. Urea of black smoke' -even!:From:NAL To;NA Voleineflaied Akieb"generated•tilk striolcg":folSOF 861S Desciiptiedotslapi to rieriiinke inii6slons: (Section LI above) Maierjaitiered:des: .. c NDLsr •01her: . Canard Weithen Ale Minim:elm: 2cC Wind Speed:Direction:" 15 MorthEest Observation by Visible Emission Observer Based en InforrnaVen..and DOW termed alter reasonable inquirjr,Icertiktharltie statements and•intontaBon in and attached to this docunientare absete acid complete. e. 4/:.Z.....,___Faculty :Supervisor. Cato 3 —R 6" -0 g AI in, Field Envitentran:al'Oempllaneedoerclinaters.ALP44 Kriaarak!' Feld, EnvironnientalCorietiande CeoidiaitoiS. NSIL.- 01 rtooeorActozis 0 IlAlpireOrmunteer;int nau. rim iii *t Viritirtg Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility April-08 Percent 91.6% 8.3% 0.1% 0.0% 100.0% MCF 19. Remarks: May 20, 2016 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 44,909 Pool Name Pool Code 7. Reinjected 3,924,347 ALPINE 120100 FIORD 120120 8. Flared or vented 1 hour or less 6,885 NANUQ 120175 NANUQ-KUPARUK 9. Flared or vented more than 1 hour (see instr.)11,354 QANNIK 120180 OTHER 10. Pilot and Purge 18,894 11. Assist Gas 12. Fuel gas used in lease operations. 477,475 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)4,483,864 Lease Use Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner Gas sold to Alpine Transportation Company = Gas gifted to Village of Nuiqsut = I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date: Rev 1. 12 May 16 Flaring approved on original. CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Apr-08 VOLUME PLANNED DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 4/12/2008 09:53 - 14:15 11,240 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti-surge valve. 4/12/2008 09:38 - 13:33 114 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti-surge valve. Total Flare > 1 Hour 11,354 Total Flare <= 1 Hour 6,885 Pilot and Purge 18,894 Total Flare 37,133 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.April -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total B. Sold 44,910 Volume. Pool Name Pool Code Percent 4,129,647 ALPINE 120100 82.2%7. Reinjected FIORD 120120 8. 3% 6,885 NANUQ 120175 0. 1%8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 9. 4% 11,354 OTHER 0. 0%9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 18,894 11. Used for lease operations (specify in Remarks) 477, 474 100.0% 12. Other (see instructions)E; .... .. i .0 Authorization >1 hr:MCF 13. TOTAL VOLUME (ITEMS 6 -12)1 a. 4.,J z t W 4,689,164 Safety MCF ;' LeaseUsee Cf 14. NGL Gas Equivalent MAY 2 3 2008 MCF Conservation 15. Purchased gas Al • , : g G ., Conn. commission Waste:MCF 16. Transferred from:Anchorage t p LL / Aft/ . 'G- 0 17. Transferred to: (Express as a negative #) Commissioner Date 18. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected toSignature n r, vv Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a temperature of 60 F. Authority 20PrintedNameDawnThomasPhone263 -4203 Date S • Zo - 7...tr6 AAC25 2.35 Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Superseded, save flaring CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Apr -08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 4/12/ 2008 09: 53 - 14: 15 11,240 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti -surge valve. 4/12/2008 09: 38 - 13: 33 114 Facility Maintenance PLANNED Repair a problem on the 3rd Stage anti -surge valve. Total Flare > 1 Hour 11,354 Total Flare <= 1 Hour 6,885 Pilot and Purge 18,894 Total Flare 37,133 GAS FLARING or VENTING REPORT e CONOCOPHILLIPS ALASKA, INC. FACILITY - Alpine - -AIR PERMIT NUMBER 488TVP01 GAS DISPOSITION Date of Occurrence:4/12/ 2008 9 Flare vent Time of Occurrence: mm/dd/yy)Check Selection)Oa00 24: 00 Minutes From:09: 53 To: 14: 16 04 :22 Total Volume Flared or Vented:11240 MSCF BBLS From:To: Planned E Unplanned From:To: From:To: Meter No. MTR-35012 By Facility)Total Minutes Flared or Vented 04: 22 Includes volume flared which generated black smoke, if applicable) A. Description of Incident and Cause: (Check as many as needed to fully describe the incident) SAD T /C#for Process upset in T/C SD due to high exhaust temperature section of facility EMERGENCY SHUTDOWN Flaring fordnlisite shutdown / startup Electrical/ Instrumentation malfunction Flare system testing Excesaivelnsuffrdent inlet gas rates into facility Faulty shutdown on X Facility Maintenance SID on high Vibration Other. Comments: This flare event was a result of taking the HP gas compressor down to repair a problem on the 3rd stage anti-surge valve. 8. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable) Started / restarted T/C #Stabilized facility process and operation Compressor / train depressured Repaired equipment difficulties Reduced / increased inlet gas rates with Completed flare testing X Facility maintenance completed Corrected E &I fluctuation / failure Other. Comments: C. Flaring or Venting was: (Check one) 9 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessa to • revent loss of ultimate recov-j Venting Incident Was the volume over 1,000 mscf?Yes: 0 No: if Yes, complete form & contact Environmental immediately) Flare Incident TRUE Did incident last for longer than 1 hour? Yes 0 No If Yes, fax this report to Environmental within 24 hours at KRU 659 - 7712 or ALP at 670.4507 i Did event cause black smoke• > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0 If Yes, contact Enviromental Immediately KRU 659 - 7242 or ALP 670 - 4200 and fax this report to Env at KRU 659 - 7712 or ALP at 670 - 4507 Black smoke' emitted from source:NIA enter tag number and description)Date and time of black smoke' event From:N/A To:N/A Volume flared which generated black smoke':MSCF BBLS Description of steps to minimize emissions: (Section B above) Required maintenance completed. Material flared:Gas:x NGLs:Other: General Weather:Air Temperature: -6 Wind Speed /Direccfoon: 8 mph East Observation . Non - Certified Visible Emission Observer Based on Information and belief formed after reason quiry, I certify that the statements and information in and attached to this document are true, accurate and cagtplete. Facility Supervisor Datet .cam J1 /C cc: Alpine: Field Environmental Compliance Coordinators, ALP -14 Kuparulc Field Environmental Compliance Coordinators, NSK- 81 Printed 41122008 S Drive/Alpine Operations/Forms /Ges Flaring or Venting GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC. FACILITY Alpine AIR PERMIT NUMBER . 489TVP01 • - GAS DISPOSITION Date of Occurrence:4/12/ 2008 O Flare vent Time of Occurrence: mm /ddiyy)Check Selection)00_ 00 24: 00 Minutes From:09: 38 To: 13: 33 03: 55 Total Volume Flared or Vented:114 MSCF BBLS From:To: Planned 0 Unplanned From:To: From:To: Meter No. MTR -35011 By Facility)Total Minutes Flared or Vented 03: 55 Includes volume flared which generated black smoke, if applicable) A. Description of Incident and Cause: (Check as many as needed to rutty describe the Incident) SF) T /C#for Process upset in T/C SD due to high exhaust temperature section of facility EMERGENCY SHUTDOWN Flaring for drglsite shutdown / startup Electrical / Instrumentation malfunction Flare system testing Excessive/insufficient Inlet gas rates Into facility Faulty shutdown on X Facility Maintenance S/D on high vibration Other: Comments: This flare event was a result of taking the HP gas compressor down to repair a problem on the 3rd stage anti-surge valve. B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable) Started / restarted T/C #Stabilized facility process and operation Compressor / train depressured Repaired equipment difficulties Reduced / increased inlet gas rates with Completed flare testing x Facility maintenance completed Corrected E &t fluctuation / failure Other. Comments: C. Flaring or Venting was: (Check one) 2 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessary to prevent loss of ultimate recovery _ Venting Incident Was the volume over 1,000 mscf?Yes: No: El If Yes, complete form & contact Environmental immediately) Flare Incident TRUE Did Incident last for longer than 1 hour? Yes El No If Yes, fax this report to Environmental within 24 hours at KRU- 659 -7712 or ALP at 670 -4507 Did event cause black smoke > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0 if Yes, contact Enviromental immediately KRU 659 -7242 or ALP 670-4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670-4507 j Black smoke• emitted from source:NIA enter tag number and description) Date and time of black smoke event From:N/A To:N/A t Volume flared which generated black smoke':MSCF BBLS Description of steps to minimize emissions: (Section B above) Required maintenance completed. Material flared:Gas:x NGLs:Other.i General Weather.Air Temperature: -6 Wind Speed/Direction: 8 mph East Observation by Non - Certified Visible Emission Observer Based on information and belief formed after reasonable • quiry, I certify that the statements and information in and attached to this document are true, accurate and complete.G// Facility Supervisor L._I Date he cc: Alpine: Field Environmental Compliance Coordinators, ALP -14 Kuparuk: Field Environmental Compliance Coordinators, NSK- 61 printed 41122008 S Drive/Alpine Operations/Forms /Gas Flaring or Venting Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility May-08 Percent 90.2% 9.3% 0.5% 0.0% 100.0% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 48,341 Pool Name Pool Code 7. Reinjected 3,862,256 ALPINE 120100 FIORD 120120 8. Flared or vented 1 hour or less 7,652 NANUQ 120175 NANUQ-KUPARUK 9. Flared or vented more than 1 hour (see instr.)1,783 QANNIK 120180 OTHER 10. Pilot and Purge 17,697 11. Assist Gas 12. Fuel gas used in lease operations.481,181 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)4,418,909 Lease Use Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner Date:May 20, 2016 Gas sold to Alpine Transportation Company = Gas gifted to Village of Nuiqsut = I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS May-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME 5/31/2008 9:23 5/31/2008 21:00 UNPLANNED 1,783 Restarting facility after shutdown Started/restarted T/C # C-33012 Total Flare > 1 Hour 1,783 Total Flare <= 1 Hour 7,652 Pilot and Purge 17,697 Total Flare 27,132 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.May -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total 48,340 Volume. 6. Sold Pool Name Pool Code Percent 4,174,456 ALPINE 120100 78.7% 7. Reinjected FIORD 120120 9. 0% 7,652 NANUQ 120175 0. 5% 8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 11.5% 1,783 OTHER 120120 0. 3% 9. Flared or vented more than 1 hour (see Instr.) 10. Pilot and Purge 17,697 481, 182 -100.0% 11. Used for lease operations (specify in Remarks) 12. Other (see instructions)Authorization >1 hr:MCF 4,731,109 Safety t " 13. TOTAL VOLUME (ITEMS 6 -12) Lease Use MCF 14. NGL Gas Equivalent Conservation MCF 15. Purchased gas Waste:MCF 16. Transferred from:j[//T" —7 `C 1C>C Commissioner Date 17. Transferred to: (Express as a negative #)f 18. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to Signature Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a Z o Z o d temperature of 60 F. Authority 20 Printed Name Dawn Thomas Phone 263 -4203 Date O AAr2R 22/ Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Superseded, save flaring CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS May -08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 5/31/ 2008 19: 23 - 21: 06 1783 Restarting facility after shutdown UNPLANNED Started /restarted T/C # C -33012 Total Flare > 1 Hour 1,783 Total Flare <= 1 Hour 7,652 Pilot and Purge 17,697 Total Flare 27,132 16, .t a ! Pla-u., ./C-k-- /P . GAS FLARING or VENTING REPORT - CONOCOPHILLIPSALASSA, INC. FACILITY - Alpine AIR PERMIT NUMBEk.. 489TV.P01 GAS DISPOSITION Date o II rrence:5/311200B r36are 0 vent Time of Occurrence: mm/d0/ChOkSeleclion)00: 00 24: 00 Minutes From:19: 23 TO: 21: 06 • .i- 0:43; Total Voltirne•Flared or Vented:1783. .MSCF BBLS.Frorn: To: Planned b Unplanned CI From:To: Frain:To: • Meter No„ MTFO5t)12 By Facility)TOtalMinutes Flared or iented 01: 43• Includes:Our* flared which.oenerated black, srocike; if applicable) A. pesdriptioiyor Incideritend Cause: (Check as Manrea needed.toltillydescribeithe 'Incident) SCP for PeriCeSe.6041.1ii TIC SD due tehign•eihadstlerriperaluM section olfacpty EMEI4G6ICY SHUTDOWhf.Flailheforddlisiie ShidaeWiti slerhil. Pies:trice)/ Initiornentation Malfunction Flare :system testing • Excessivcrinsufficlentintet gas rates into facility'faulty shutdown on FaciliisiMainienabce Other: restarting ficillty•after shutdown Comments: this Aare:event Occurred While:the.tadllityiniasbeirip restarted after a shutdown. Thithuldoitin eccurred'because.the fire.detection for aortmess.module wasoot while fireiiistemleSting Was:beitie:performed. When the.maintenance departmentmanuallynionered a iredeleCtion device.In'thls.modOle the olantshut down: s:Action Taken to.Eiiminate cause and Prevent Recurrence: (Check and applicable) X Started./.1eStarted TIC # ..C-33012 Stabilized facillty.prOCeSsendoperation Compressor / train depressured Repaired equipment ReduCedfincreaSedirilefgaS rates with- Completed flare testing:FaCilftymaintenance.completed Correcied..E&I fluctuatidnifillUre•PtilBr: Comments: O.:Flaring or.VentingWas:.(ChecIc one) 1: 1 necessary for facility operations repairs, upgrades, *or testing procedures 0 an emergency that threatened life or property. O . .n ad Os a r y "to pre ii ant rose df-ultiniate'recovery Venting - Incident Iii/as:nievolume over 1,000.mscf?Yes: !No: 0 .If Yee,COMPlete fOrmkcOritactEnyininmeidafilireediately) Flare Incident TRUE Did ihoiitoriy160,161 longer ttfah •rhour7 Yes 0 6.10 0. IF Yes,latihie.repOrt to•Erivironmental within 24, hours at KRU- 659:7742.orALP at 6704507 Did event cause black smoke> 3.mintries in 1 hror 6.consecutiyemintites?Yes: 0 No: 9 If Yes, contaCt.Enviromental immediately KRU 6594242.or -ALP 5704200 and.fax this reportio.Env at KRU- 659712 or ALP at 670-4507 Black Stripke'tmitted trim Sciurce:enter-tag number and description) Date.and time. Of blacksmcike! event:From:To: Volume Pared black smoke'.MSCF BBLS eSPrigitinis of steps to minim emissions (SectiOn•El above) Material flared:Oas:x 1IGLs:Other: Demerol Weather:Air Temperature: 32 Wind Speed/Direction: 15 mph/SE tiV'tloil-Dertined VISIble'ErnisSiOnObienier Based on information and belief formed after-Masenable:iriquItY, I thallha.statements artd:Inforrnatidn.in•and attached to this document are true; accurate and complete. Facility Sirpervisor Date cc:. Alpine: Field Environmental Compliance•Coordinators,ALP-14 Kiiparuk: Field Compliance rdinakirs, NStc Prinreetrii2008 S DrivelAiPias Opw /Gas flaring or Ventind 4 Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility June-08 Percent 90.2% 9.3% 0.5% 0.0% 100.0% MCF 19. Remarks: Date:May 20, 2016 Gas sold to Alpine Transportation Company = 37440 Gas gifted to Village of Nuiqsut = 177 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)3,908,620 Lease Use 11. Assist Gas 12. Fuel gas used in lease operations.430,642 10. Pilot and Purge 10,528 9. Flared or vented more than 1 hour (see instr.)4,308 QANNIK 120180 OTHER 8. Flared or vented 1 hour or less 16,187 NANUQ 120175 NANUQ-KUPARUK Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 37,615 Pool Name Pool Code 7. Reinjected 3,409,340 ALPINE 120100 FIORD 120120 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Jun-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME 6/17/2008 10:54 6/17/2008 12:32 UNPLANNED 1,524 False fire detection Started/restarted T/C # C-33012; stabilized facility process and operation 6/17/2008 10:29 6/17/2008 12:02 UNPLANNED 2,273 False fire detection Started/restarted T/C # C-33012; stabilized facility process and operation 6/7/2008 9:06 6/7/2008 10:37 UNPLANNED 511 Excessive/insufficient inlet gas rates into facility Reduced/increased inlet gas rates Total Flare > 1 Hour 4,308 Total Flare <= 1 Hour 16,187 Pilot and Purge 10,528 Total Flare 31,023 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.June -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total 37,617 Volume. 6. Sold Pool Name Pool Code Percent 3,678,938 ALPINE 120100 76.1% 7. Reinjected FIORD 120120 8. 9% 16,187 NANUQ 120175 0. 5% 8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 11.7% 4,308 OTHER 120120 0. 4% 9. Flared or vented more than 1 hour (see instr.)OTHER 120185 2. 4% 10,528 10. Pilot and Purge 430, 642 100.0% 11. Used for lease operations (specify in Remarks) x,a as a rvr 12. Other (see instructions)Authorization >1 . hr: Safety 3E MCF 4,178,220 13. TOTAL VOLUME (ITEMS 6 -12)MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from: Commissioner Date 17. Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to Signature Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a temperature of 60 F. Authority 20 Printed Name Dawn Thomas Phone 263 -4203 Date — 1 • t o g AA r2s 2? 9 Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit In Duplicate Superseded, save flaring CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Jun -08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 6/17/2008 10: 54 - 12: 32 1,524 False fire detection UNPLANNED Started /restarted T/C # C- 33012; stabilized facility process and operation 6/17/2008 10: 29 - 12: 02 2,273 False fire detection UNPLANNED Started /restarted TIC # C- 33012; stabilized facility process and operation 6/ 7/2008 09: 06 - 10: 37 511 Excessive/insufficient inlet gas rates into fat UNPLANNED Reduced /increased Inlet gas rates Total Flare > 1 Hour 4,308 Total Flare < =1 Hour 16,187 Pilot and Purge 10,528 Total Flare 31,023 GAS FLARING ENTING REPOR1% CON.00OFHILLIPSAil. ..:•.icA, A.„..$-?.: INC: 77"...5 - -;•Yrzztx1foR - 47;m1 - .211 , ..;•M r,-...41,tr:::.sm,7iiimFACILITY:AIR PERMIT NUMEIER: GAS DISPOSMOW Datif.bt,OcOnctinier.1311712220 O'FliM.. 0*-it tiiiii ofdeenrcihnet- terittddlyk)Cheet.SeteeF201 00: 00: - ' ' 24110:PRO? Fr.OM:ilia T.:c 12ioi 2 01:3' Total Volume Flared or:Vented:2271.- .14.SCF BLS -From:to: Planned 0 Unplanned 0 From:To:- Fni2f:t et. '' tictee:No: - ..mtg;35v11 By Facility) ' '.intalatIntitea iieiediiiteiittiel iiiiis. Ii4aitideivirdiuthollarailiAlt ti.gorarkted bli3ektmbke;.ilapplicable): c. iti*dpcion;litinClitetit 1ind.c.46:iii:Igirik ;iliAaleo.lie Prins (Odic In lit &D..00.0,1anh echausitoraperatare R:?!=!lis.c cicilitY' tidtridtalcYtillitil'aiii Friiiiii iei'drliiileittutdiatiitlirtup,EieCtitat / ImInintenckicarnalinia(liti .Floito*nin vial* 1 Infra gaaluter; it111) WW1,.Falai shadorm on 0.12 0.i. 149 24 10'Mini litgli tignisticiit X Oihcit: ' FfirdAntiClidn ' Gcmmun6 8,,AeltOninIteeln:ElheInittct Gave* -- .'.',..endfrevinit.Rentiirenitetrlictelt:CaidclOicittia'ati . apillailitetiiSd(roatattrrdT)& iiiii I'M 0 .X rinkaraf*rationCortitanditircesutcd ..ikkip0froil'a4tiliniiin ditlithilliei Rid uced thibreasad inlet On rates aith Oarnntatad.ilatOlCiiirii.FaidWritithileritinCiaaciarplotad.dceraited Eitiltintuatiati I/allure ottiOe orimardei' C.PleilitgleVentInOwato pick. onto. tj' aeci for facilliY oPeratonc.: reFeIrs;:unaradeColtestinn : math - yea E1 On Cmergenty that threatened lifiior*opertje 0 - rionessarylo.prevein Intact unimaterecovery Ventiiiii hiaideiit' tivii 601 igleii roc ' 0 Ro t' 0 .If Yes ; or:imitate to* & contact EnvIronniorital Immod*Iy) flare thoident"TRUE litditic-,:deot InettO1 longer intili:i.1100i? 203 El k6: .t if file ttigiepo;t toEnainanitionial ivitiski 24 hours at KRU- 859421; OrALI. at 4204502 Didationtadisse-binek smoke` > 3 minutes in 1 tireca.consecielve'mlnuttra?Yea: • 0 NO: 0 twee; contact Exiidramneentimricitlialehr KRU'660-7242 Or ALP 67042004nd fax thin report tiiEnt.unt ISRI.1= is94712 oi At-V at 472-4302 Sack smoke'. emitted from actiroat.anti tag number arid dekerigton)gate :end time Of Otack sdaille. avant From To Volndetiertid050.0genarcite5 black smoke :543C F BaLS Piiserftitittit dr - ate2316 artirilmizo Oidevions:',(Scd. inn B above) Material gated:310 X NUI:C Mei*: 9000.:i'VePOI°rt Air TaMparaturo: .45 Wituf:So.euduclion:10 -mph Illbeerenticet1410i........... /entail Observer Based on lidetnialletienit belief renned aiteenanataiikte•Inquity. Iccitiklhat the statamente and information in and attached to thisCinevinemtaittlitio. accurate; and 'aciptele.: Facillty Siagitrvidor:Date' k / 7 70. is' cc: -Al inn: Field Environmental Compliance COttlinntois,'ALP447/ 10 Pali EnvItentheali COM011ente CoeciOnlitnte. ItSK-'21. R-raz romit 3 Fla* Gat ReNtrentuds.0. 1.S70:13 41 .....- i iGASFLARINGtr( ..;::NTINO REPORT ',.; cpwocoinfiLuPa ..tA., RIC. OliViAl.W...N., ...f4"4" ' - kOILITY: stalli*AF ... - - , 45,,imo, 4 AIR fitERMIT NUMBER:' 1 ..i :... OfignWia:il'A GAS SiSPOSMON Pater otGosermete 3,;t7f1063 -in Rift Oi. itfi Mini ‘Oftectirtioce: dfoiddify!Chet lc Seledion),: moo Fred:dim, T. 1232 = oelti riite:11.ViiktiM FtS5td 60Si:enby);1324 f;r4F astt Frosio To at Pienned • '0 Ofedaidifil - 0 From.To:. • From TS;e • 1iel* s tITR 53012 , 'c.",31i Fiffi16til Ofnikilfg4ii,ft 011a i I :- . , Oilquevesiyblutni'fiamoi won'tienetated blecitersolte, Ifvpilfd L.Desalption ortoddest ent.dattoof {Omit #$ mator,Is.pcptiest tc infix ,tiijoi*e. *Idonij 0 . 0r 414 to:* efe.efefferifpoisteni -4 : 305 , n rtiOtilf RAF.R.q.E40"s1:44rPowtt „r*:.•rii piraillsii6 stLitilitini./.**11 Gortridi i Inineffeitsiefiindturisle'”r.;liefitetiffiiiiiiifie 4"Sf.40se,kuiitAirIffiSisr. fidoi fwlifif.retAiderfes." fieffity Wiirelsore-Siq on 00:04ition X out fetal:he Gi:ificTsoo - Coideiteief Thitti4efiefifwee.caiissidisi e s* stiutifsivii,.11dithuidoodarairlid die bStaiscrutpdetedloolo.afrAloirio 'O'rodne inodidelocouid4O Kurartik: 8.:AesailTdisitsplieliiste raiiseeed prevestueffurrencoleScdf andderrsdper oppeceoloy 3iariedifsda41 Ti4,.'"A - •r;-330t2 :X Stiii{giiiffiefidip **it* 6O4piesier)frilifferriairsvid Ntt edlifimentdduci:diei ReducettKlessed Wet gestates din Comp*tedisne.tostrig FiOritijiiitle"AfKik'' 32iPPI"* . COitecti4E313fidietlefi / felt*r:.Mie Caritteerds:" Oiioqiciiive.Tig •Yo'i,:OfieiktliNti 1 :i * 411 #* PO'-#.461'Et . eit eniemenOydetdreatered We or Froperty" 0 ideissi4-iariiiiiisi6e Or fdtii A.. Arentifidfnettferft fide Mode over MOO insert.Yet: 1 : 3 No: . 0:"liTesf.OomPleffi4004 iiiilliftriliktelsii. Flare Incidents TRUE Uld looldenttestro fooselden 1 : hotif. Tes .. 0 ilo 0 it irefr,f#04reped talievipseeepUtei within heirs 4 Piti orotF*e b!oot IffiGico"? 3mieitA*4441 1 Oir*ti b Rd: 0 If i'eff,..eoniast etitrorosislat ladiodidetv kin, 042.4:tiir *04044'0i:0d tkiiii6repiiit*EulvdtOU- 658-7712 Or ALP at 6704507. ill** sR0a':ufrald from amiiin:tentertegos.d* aro "cieesfipiony ailli:iiiiitt*.ot.t*Comai*:evilit Rom:To Val'uliki):16'1A4P3siWa,CablablOragt*A94;l',63UF. "33i.3. biiefgeOtteldiefdize.efolselens: (Section 3 etioVo) Stabitized faatv pressure compressor C-320i2: MIAOW *oil::: . Gas: ' ' X NGLS:',... : Defer: 00*':' 'AreOhO'!itis-ToinpSfelum 43 F. Wind -SpoodiDir&iiiolV,10 reps C...13 ,oiiflon Visiblos Ossenter- aiiirdOinktutagerfas0 b00.4 roasonfdds inedifY,Icedy thettse•sleternerds Aud iromptg,Iott 1, 0 and e#actufd toe deeve:ient*finf,,eaddideend OSISide1S, Me & f - 40e - 1 iaci.. tilt §di a AA, " ' r Ai :::Fi..fteiriritantirtibl ..L - .90: 2 -Oi; 4. 96 ;iiatOotA-ALR:14:-. • Kiiperidr tiold eii4ron'enenti.OirtipOatiie uSaidlisiteie.:N3R 61 4:01707/024:12FItit,k9ttgi V - ; lie 1 Aif – r • — — C.:0 r GAS FLARING or VENTING. REPORT - CONOCOPHILLIPS ALASKA, INC. FACILITY: - Alpine AIR PE MIT NUMBER .4S9IV.Pdi. GAS DISPOSITION. Date 'of Occurrence:5:72000 2 tle:e Ovrrc Tinto or Occurrence: • 0nmidtFYYt iChs7:.: S=20::tic 0000 74: 0a,minutes From:0:06 To; 10:3? ' = 01: 31- Total Volume 'Flared.or Vented:511 1,1577 EiBLB From: Planned: El Unplanned 0"From To: Frain, rowel 140. - 1.tTtiLl5012 I rir Fatality/ToUt Mimes' Flared or Vented in 01: 31 It/l:oludesvciumeflured which generated black smoki,Yapplicabloy A. oe'sertatIon et Meldeet end CausiE.p)ack es merweseeeded to tollY se SCnt it" InC S. VC*kV Process asset in 11c sb dim le hoh oriverusetimeresee ulcer of today EMI.EfiG0,161" S4•4111V31Alt4 flarfrii rat dalsOn ahulthourpsforis;p • lo:1&• 11./ InskinuontritiOO rthaurclion Faro simtcoilosaog • X exonatIvOlcoracionl allot per MID DAD focal".Foully 318'41,104n on Focuw meiettmeiwe ID nil kith vibration- Other: Comments: Al.uppioximalaly 0:00AM Me rectify expononcod a tame allow or riaS rho troarr.k apen)184 boo= seeking -for the Source or the as and slreuttimeousli banter to llienttha kali 4coorrit,...veint. Ti,e, souico or iho gas was evontualtoracui to-n relatively. low rate wart 'on 02 Mat had re.. la production The pus ratiirOnt IttliVoilLpilblriciiitl! eineuditd Mal horn- Previous Wei terds. Anew well waselse be-mm: triwoht 0nrirte Uyv at%ocoMpli4mMlihe ttioignilootfol. B. ittlion Takao icif.lholnala Copal, and Provant Tfocsioanca: (Chock and tlasofifie as appfCial0 Blurred / rostaned TIC 4'Sh011ized facility. process Andopuralsm BOotIllearrot 1 treln dohieesuied Prepared equipment dittlitillies k Reduced 1 increased Rite! Luis tides OOmplerc-rfriate losla Facility-maintenance completed COttecrerl EXI llUctuallon 00;0,0 Other Comninnle: C,:Flaririn or.VoltithiguaiL(Ch'eck one) 0 neoesserytorfacility operations, repails.;:uPgrades, or leslioll PrOCelfffa5 an urnerouncy that Mu:atoned' lite or property ci rieesalyto_prevent loss of uternate iecovelv Venting Malt:lent. Was Illo volume over 1 'i000 (140?1 ... 0 tic. 0 til yes complete form & contact Environmental irnmedlitto44 Flare Incident'TRUE Oiciincident last foi longerthun 1 hour? eA . 2.1 ; , ..)0 II Yes, fax this .rapori to Environmental within 24 hours at•KRU, 6B94711 orAl.P at 570!4507 bid eiant 004 ittaa:sinclie", 3'41h in i hrti S voneecobve mintr.les?r 0 Nu 0 If yes, copied Envinmentailinmontlett lOill 659-7: 24?.. or ALP 610-4200 and *this report co Env at KEU-4494712:or ALP at 4744507 Black Meal** eMilleiti hem SeurOS;era:via:a number and deszriptien) BataanritTenertd black irpice air! :From To Vekineriered %Nab generated black smoke"kl,BCF 813LS 1*-0iptien CitittePa to Mink:nice emissiona. (Section B abm'e) trial tiered:-Pas:x HOW.Other. 4. 0441 . *AirTemperatare. 45 WSosedaDirecrion: 10 mph Obstsvailein by Nouterldied ViSitile' Emission Crhse, Based on iirlenit.atien and be mad after te4san : iiaquiry_l *try that tite.-stare.vira ard,infemtatian in and attached totheidecument-are.hue; accurate and Wein FatilitySuperiiiSor Dates cc' Alpine: Field Environmental Compliance Cotedir,,etars.Al2,1-1' Ktiparuk littld En lronmental Comfriarioe Cocitineters. USK- 51' Pmla. 111.7010 I Cf!...vAlvarm - .7nrc2rwsr...Fortin.q.lax , :1;telvs *r Vs'amil Y Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility July-08 Percent 89.3% 8.8% 0.6% 1.4% 100.0% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 46,808 Pool Name Pool Code 7. Reinjected 3,587,390 ALPINE 120100 FIORD 120120 8. Flared or vented 1 hour or less 11,814 NANUQ 120175 NANUQ-KUPARUK 9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180 OTHER 10. Pilot and Purge 14,597 11. Assist Gas 12. Fuel gas used in lease operations.438,375 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)4,098,984 Lease Use Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner Date:May 20, 2016 Gas sold to Alpine Transportation Company = 46017 Gas gifted to Village of Nuiqsut = 791 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Jul-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME Total Flare > 1 Hour 0 Total Flare <= 1 Hour 11,814 Pilot and Purge 14,597 Total Flare 26,411 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.July-08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total 46,817 Volume. 6. Sold Pool Name Pool Code Percent 3,883,481 ALPINE 120100 74.4% 7. Reinjected FIORD 120120 8. 4% 11,814 NANUQ 120175 0. 6% 8. Flared or vented 1 hour or less NANUQ-KUPARUK 120185 12.1% 0 QANNIK 120180 1. 4% 9. Flared or vented more than 1 hour (see Instr.)OTHER 3. 1% 14,597 10. Pilot and Purge 438, 376 100.0% 11. Used for tease operations (specify in Remarks) 12. Other (see instructions)Authorization >1 hr MCF 4,395,08 Safety 13. TOTAL VOLUME (ITEMS 6 MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from: Commissioner Date 17. Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the foregoing is t; e an. correct to the best of my knowledge. Note: All volumes must be corrected to Signature 4 La tVi Title Supervisor, Revenue & Regulatory pressure of 14. 65 psia and to a Printed Name Julie Sale Phone 4041/"S5,2 3 Date / I / ZOOP temperature of 60 Authority 20 AAr95 746 Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Superseded, save flaring STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.July-08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 3,883,481 ALPINE 120100 74.4% 7. Reinjected FIORD 120120 8. 4% 8. Flared or vented 1 hour or less 11,814 NANUQ 120175 0. 6% NANUQ- KUPARUK 120185 12,1% 0 QANNIK 120180 1. 4% 9. Flared or vented more than 1 hour (see Instr.)OTHER 12012[7 0. 4% 14,597 OTHER 120185 2. 8% 10. Pilot and Purge 438, 376 100.0% 11. Used for lease operations (specify In Remarks) 12. Other (see instructions)t;;_:G... r <i% 4f r ..,,..., , ,, , se' !?.Y :a ; ,.:. ; r i3 j is jjl(a} I'.= ;• Authorization >1 hr: Safety MCF + 4,395,085 13. TOTAL VOLUME (ITEMS 6 -12) MCF Lease Use 14. NGL Gas Equivalent Conservation MCF 15. Purchased gas Waste:MCF 16. Transferred from: 17. Transferred to (Expre i : Commissioner Date W4: 18. Remarks:p ' r* rte :: r tt, e, FrIEfirh I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected toSignaturIA-ZAs Title Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a temperature of 60 F. Authority 20PrintedNameDawnThomasPhone263 -4203 Date p • 2. 0 •'7a053 AQC2 . 5 2. 3 Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility August-08 Percent 88.3% 9.6% 0.8% 1.3% 100.0% MCF 19. Remarks: Date:May 20, 2016 Gas sold to Alpine Transportation Company = Gas gifted to Village of Nuiqsut = I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)2,118,800 Lease Use 11. Assist Gas 12. Fuel gas used in lease operations.267,276 10. Pilot and Purge 17,642 9. Flared or vented more than 1 hour (see instr.)2,084 QANNIK 120180 OTHER 8. Flared or vented 1 hour or less 6,857 NANUQ 120175 NANUQ-KUPARUK Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 23,909 Pool Name Pool Code 7. Reinjected 1,801,032 ALPINE 120100 FIORD 120120 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Aug-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME 964 1,120 Total Flare > 1 Hour 2,084 Total Flare <= 1 Hour 6,857 Pilot and Purge 17,642 Total Flare 26,583 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.August -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total 23,910 Volume. 6. Sold Pool Name Pool Code Percent 1,944,832 ALPINE 120100 69.9% 7. Reinjected FIORD 120120'9. 3% 6,657 NANUQ 120175 0. 8% 8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 13.4% 2,084 QANNIK 120180 1. 3% 9. Flared or vented more than 1 hour (see instr.)OTHER 5. 3% 17,642 10. Pilot and Purge 267, 275 100.0% 11. Used for lease operations (specify in Remarks) 12. Other (see instructions)Authorization _1 hr.MCF 2,262,60C Safety 1 13. TOTAL VOLUME (ITEMS 6 -12) L 1 MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from: Commissioner Date 17. Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the for oing is true and corn . to the best of my knowledge. j Note: All volumes must be corrected to Signature 14 —Title Supervisor, Revenue & Regulatory pressure of 14. 65 psia and to a on(g)4G/ 5 ' , 2? Date /t /9 /2G Ar: temperatureof60 Authority 20 Printed Name Julie Sale Ph a95 2g5 Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Superseded, save flaring CONOCOPHILUPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Aug-08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 8/ 9/2008 10: 58 - 12: 34 963.6 Planned facility maintenance shutdown PLANNED Stabilized facility process and operation 8/22/2008 1:51 - 7:58 1,120 Re- inventory of oil section to prepare for ant PLANNED Re- inventory of the oil section of the facility completed Total Flare > 1 Hour 2,084 Total Flare < =1 Hour 2,084 Pilot and Purge 17,642 Total Flare 21,810 GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC. FACILITY:Alpine AIR PERMIT NUMBER: 489TVP01 GAS DISPOSITION Date of Occurrence:8/ 9/2008 0 Rare vent Time of Occurrence: mm/dd/yy)Check Selection)00_ 00 24:OQ lXnutn From:10: 55 To: 12: 34 a 01: 36 Total Volume Flared or Vented:963.6 MSCF BBLS From:To: Planned 0 Unplanned From:To From:To: Meter No: MTR-36012 By Facility)Total Minutes Flared or Vented a 01: 36 Includes volume flared which generated black smoke, if applicable) A. Descrtpttan of Incident and Cause: (Check as many as needed to fully describe the Incident) SID 1/Cie for Process upset in T/C SD due to high exhaust temperature section of fse7ity EMERGENCY SHUTDOWN Flaring for details shutdown /startup Electrical / Instrumentation malfunction Flare system testing Fxcessive/bnulficient inlet gas rates into facility Faulty shutdown on X Facility Maintenance SID on high vibration Other Comments: This flare event was caused by a planned facility maintenance shutdown. 8. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable) Started / restarted T/C S X Stabilized facility process and operation Compressor / train depassured Repaired equipment di fiadties Reduced / increased inlet gas rates with Completed flare testing Facility maintenance completed Corrected ESi fluctuation / failure Other: I Comments: C. Flaring a: Venting was: (Check one) 0 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessary to prevent loss of ultimate recover Venting Incident Was the volume over 1,000 mad?Yes: No: If Yes, complete form & contact Environmental immediately) Flare Incident TRUE Did incident last for longer than 1 hour? Yea El No If Yes, fax this reportto Environmental within 24 hours at KRU- 559 -7712 or ALP at 6704507 Did event cause black smoke• > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0 I If Yes, contact Erviromental immediately KRU 669.7242 or ALP 670-4200 and fax this report to Env at KRU- 659-7712 or ALP at 670 -4507 Black smoke' emitted from source:enter tag number and description) Date end lime of black smoke' event From:To: Volume flared which generated black smoke':MSCF BBLS Description of steps to minimize emissions: (Section B above) Material flared:Gas:X NGLs:Other. General Weather.Air Temperature:Wind Speed/Diredion: Observation by Non - Certified Visible Emission Observer Based on information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this document are true, accurate and complete. Facility Supervisor Date g---// as. cc: pine: Field Envuon I Compliance Coordinators, ALP -14 Kuparuk: Field Environmental Compliance Coordinators, NSK- 81 080908 Rare Gas Repel Fan ,cis 8/1112008 I GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC. FACILITY- SAlpme':- UT .;' _ =.AIR PERMIT NUMBER •-489TVP0 . c Y:.. DISPOSITIONGASDIOSI Date of Occurrence:8l22/2008 Flare vent Time of Occurrence: mm/dd/yy)Check Selection)00: 00 24130 Minutes I From:01a51 To: 07:5s 007 I Total Volume Flared or Vented:1120 MSCF BBLS From:To:I Planned 9 Unplanned From:To: From:To: Meter No. MTR-35012 By Facility)Total Minutes Flared or Vented 05: 07 Includes volume flared which generated black smoke, if applicable) A. Description of Incident and Cause: (Check as many as needed to fully describe the incident) SID TRH for Process upset in T/C SD due to high exhaust temperature section of facility EMERGENCY SHUTDOWN Flaring forddyste shutdown /startup Electrical / Inetnanentation malfunction Flare system testing Excessivedrouf6dent inlet gas rates into facility Faulty shutdown on X Facility Maintenance S/D on high vibration I Other. Comments: Flaring was required for re- Inventory of the oil section of the facility to prepare for upcoming start up following annual shutdown for maintenance. ii Ir 1 a Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable) Started / restarted T/C*Stabilized facility process and operation Compressor I train depressured Repaired equipment difficulties i Reduced / increased inlet gas rates with Completed flare testing Facility maintenance completed Corrected E &I fluctuation 1 failure x Other.I Comments: Re-Inventory of the oil section of the facility completed. i I C. Flaring or Venting was: (Check one)j 9 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessary to prevent foss of ultimate recovery Venting incident Was the volume over 1,000 mscf?Yes: No: If Yes, complete form & contact Environmental immediately) Flare Incident TRUE I Did incident last for longer than 1 hour? Yes O No If Yes, fax this report to Environmental within 24 hours at KRU- 659 -7712 or ALP at 670 -4507 Did event cause black smoke' > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: 0 If Yes, contact Enviromental immediately iCRU 659 -7242 or ALP 670 -4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670 -4507 Black smoke emitted from source:enter tag number and description)j Date and time of black smoke event From:To: _ Volume flared which generated black smoke:MSCF BBLS Description of steps to minimize emissions: (Section B above) Material flared:Gas:X NGLs:Other. General Weather.Air Temperature: 40 Wind Speed /Direction: 10 mph I Observation by Non - Certified Visible Emission Observer Based on information and belief formed after reasonebl • uiry, I certify that the statements and information in and attached to this jdocumentaretrue, accurate and o G Facility Supervisor 7' 4 Date 8 / //Z3 /I cc Alpine: Field Environmental Compliance Coordinators, ALP -14 Kuparuk: Field Environmental Compliance Coordinators, NSK- 81 t 1 i R pmfet:1 8/22,200e S Olive/Alpine OperadonslFonns /Gas Flaring or Venting t s Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility September-08 Percent 88.8% 9.8% 0.7% 0.7% 100.0% MCF 19. Remarks: Date:May 20, 2016 Gas sold to Alpine Transportation Company = 48389 Gas gifted to Village of Nuiqsut = 1941 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)3,774,639 Lease Use 11. Assist Gas 12. Fuel gas used in lease operations.450,775 10. Pilot and Purge 12,295 9. Flared or vented more than 1 hour (see instr.)5,425 QANNIK 120180 OTHER 8. Flared or vented 1 hour or less 9,956 NANUQ 120175 NANUQ-KUPARUK Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 50,330 Pool Name Pool Code 7. Reinjected 3,245,858 ALPINE 120100 FIORD 120120 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Sep-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME 5,425 Total Flare > 1 Hour 5,425 Total Flare <= 1 Hour 9,956 Pilot and Purge 12,295 Total Flare 27,676 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.August -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total 23,910 i Volume. 6. Sold Pool Name Pool Code Percent 1,944,832 ALPINE 120100 69.9% 7. Reinjected FIORD i 120120 9. 3% 6,857 NANUQ ;120175 0. 8% 8. Flared or vented 1 hour or less NANUQ- ICUPARUK 120185 13.4% 2,084 QANNIK i 120180 1. 3% 9. Flared or vented more than 1 hour (see Instr.)OTHER 120120 0. 2% 17,642 OTHER 120185 5. 1% 10. Pilot and Purge OTHER i 120100 0. 0% 267, 275 100.0% 11. Used for lease operations (specify in Remarks) iy is;'% d. aiial: Use;O i' Instructions)Authorize 1,:,.on >1 ..,.,.:: r; =,. :.:::ii >_ ,.- ..,.,x 12. Other (seelns ti hr. Safety 2 MCF ilex,13. TOTAL VOLUME (ITEMS 6 -12) 2,262,600 f! y MCF Lease Use 14. NGL Gas Equivalent MOF Conservation 15. Purchased gas Waste:MCF i it 0 - 2.- Ilk i Commissioner Date 17. Transferred to (Expre t ° I, II 18. Remarks: I hereby certify that the foregoing Is true and correct to the best of my knowledge. Note: All volumes must be corrected to Signature Title Supervisor, Production & Re Accounting pressure of 14. 65 psia and to a temperature of 60 Authority 20 Printed Name Dawn Thomas Phone 263 -4203 Date a• IA . "2_ 0 08 AAr 2A 935 Superseded, save flaring CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS 1 Aug -08 VOLUME I PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 8/ 9/2008 10: 58 - 12: 34 963.6 Planned facility maintenance shutdown j PLANNED Stabilized facility process and operation 8/22/2008 1:51 - 7:58 1,120 Re- inventory of oil section to prepare for an PLANNED Re- Inventory of the oil section of the facility completed Total Flare > 1 Hour 2,084 Total Flare < =1 Hour 6,857 Pilot and Purge 17,642 Total Flare 26,583 I I GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC. FACIUTY:Alpine AIR PERMIT NUMBER: 489TVP01 GAS DISPOSITION Date of Occurrence:8/ 9/2005 OFare Vent Time of Occurrence: mm/dd/yy)Check Selection)00: 00 24_ 00 Minutes From:10: 88 To: 12: 34 01: 36 Total Volume Flared or Vented:963.6 MSCF BBLS From:To: Planned El Unplanned From:To: From:To: Meter No: MTR -35012 By Facility)Total Minutes Flared or Vented 01: 36 Includes volume flared which generated black smoke, if applicable) A. DescripSon of Incident and Cause: (Check as many as needed to fully describe the incident) SID T10#for Process upset in T/C SD due to high exhaust temperature section of facility EMERGENCY SHUTDOWN Flaring for drillsite shutdown / startup Electrical / Instrumentation malhmdion Flare system testing Excessive/insufficient inlet gas rates into facility Faulty shutdown on X Facility Maintenance S/D on high vibration Other. Comments: This flare event was caused by a planned facility maintenance shutdown. B. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable) Started / restarted T/C #X Stabilized facility process and operation Compressor / train depressured Repaired equipment difficulties Reduced / increased inlet gas rates with Completed flare testing Facility maintenance completed Corrected E &I fluctuation /- failure --- - - - - --- •- - - - - -- - Oilier. - - Comments: C. Flaring or Venting was: (Check one) El necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessary to prevent loss of ultimate recovery Ventina Incident Was the volume over 1,000 mac??Yes: No: If Yes, complete form & contact Environmental immediately) Flare incident TRUE Did incident last for longer than 1 hour? Yes 1: 1 No if Yes, fax this report to Environmental within 24 hours at KRU- 669 -7712 or ALP at 670 -4507 Dld event cause black smoke > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: Q If Yes, contact Enviromental immediately KRU 659 -7242 or ALP 670-4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670.4507 Black smoke` emitted from source:enter tag number and description) Date and time of black smoke event From:To: Volume flared which generated black smoke`:MSCF BBLS Description of steps to minimize emissions: (Section 6 above) Material flared:Gas:X NGLs:Other. General Weather.Alr Temperature:Wind Speed/Direction: Observation by Non - Certified Vislbte Emission Observer Based on Information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this document are true, accurate and comFacilitySupervisor jW`Date a ( _//_ 498 cc: • pine: Field Env n ntal Compliance Coordinators, ALP-14 Kuparulc Field Environmental Compliance Coordinators, NSK- 61 050908 Flare Gas Report Formals III a/1112008 j J /'GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC.M sv ' AIR PERMIT NUMBER s4t39TFACILITY - - Lpne: ?;.*::,+: GAS DISPOSITION Date of Occurrence:8/22/ 2008 0 Flare Overt Time of Occurrence: mm/dd/yy)Check Selection)00 :0Q 24: 00 Minutes From:01: 51 To: 07: 58 08: 07 Total Volume Flared or Vented:1120 MSCF BBLS From:To Planned 0 Unplanned From:To: From:To: Meter No. MTR -35012 By Facility)Total Minutes Flared or Vented 08: 07 Includes volume flared which generated black smoke, if applicable) A. Description of Incident and Cause: (Check as many as needed to fully describe the incident) SID T /C#for Process upset In TIC SD due to high exhaust temperature section of facility EMERGENCY SHUTDOWN Flaring for dnlisite shutdown /startup Elechical / Insuumenlation malfunction Rare system testing Excessivennsuf0dent Intel gas rates into facility Faulty shutdown on X Facility Maintenance S/D on high vibratkn Other. Comments: Flaring was required for re- Inventory of the oil section of the facility to prepare for upcoming start up following annual shutdown for maintenance. 8. Acton Taken to Eliminate Cause and Prevent Recurrence: (Check and describe as applicable) Started / restarted T/C #Stabilized facility process and operation Compressor/ Lain depressured Repaired equipment difficulties Reduced / increased inlet gas rates with Completed flaretesting Facility- maintenance- completed - -- Corrected E&I fluctuation / failure X Other: Comments: Re- inventory of the oil section of the facility completed. C. Flaring or Venting was: (Check one) El necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessary to prevent loss of ultimate recovery Venting Incident Was the volume over 1,000 mscf?Yes: No: if Yes, complete form & contact Environmental Immediately) Flare Incident TRUE Did incident last for longer than 1 hour? Yes O No If Yes, fax this report to Environmental within 24 hours at KRU- 659-7712 or ALP at 670 -4507 Did event cause black smoke > 3 minutes in 1 hr or 6 consecutive minutes?Yes: No: O if Yes, contact Enviromental immediately KRU 659 -7242 or ALP 670.4200 and fax this report to Env at KRU- 659 -7712 or ALP at 670 -4507 Black smoke* emitted from source:enter tag number and description) Date and time of black smoke* event From:To: Volume flared which generated black smoke *:MSCF BBLS Description of steps to minimize emissions: (Section B above) Material finned:Gas:X NGLs:Other. General Weather.Air Temperature: 40 Wind Speed/Direction: 10 mph Observation by Non- Certlled Visible Emission Observer Based on information and belief formed after reasonabi ulry, I certify that the statements and information in and attached to this document are true, accurate and 9omplete. Facility Supervisor Date S`a / cc: Alpine: Field Environmental Compliance Coordinators, ALP -14 Kuparuk: Field Environmental Compliance Coordinators, NSK- 61 Printed 82212008 S Wive /Alpine Operations/Forms /Gas Flaring or Venting Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility September-08 Percent 88.8% 9.8% 0.7% 0.7% 100.0% MCF 19. Remarks: Date:May 20, 2016 Gas sold to Alpine Transportation Company = 48389 Gas gifted to Village of Nuiqsut = 1941 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)3,774,639 Lease Use 11. Assist Gas 12. Fuel gas used in lease operations.450,775 10. Pilot and Purge 12,295 9. Flared or vented more than 1 hour (see instr.)5,425 QANNIK 120180 OTHER 8. Flared or vented 1 hour or less 9,956 NANUQ 120175 NANUQ-KUPARUK Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 50,330 Pool Name Pool Code 7. Reinjected 3,245,858 ALPINE 120100 FIORD 120120 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Sep-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME 5,425 Total Flare > 1 Hour 5,425 Total Flare <= 1 Hour 9,956 Pilot and Purge 12,295 Total Flare 27,676 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. MonthNear of Disposition 1 030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.September -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total 50,348 Volume. 6. Sold Pool Name Pool Code Percent 3,548,540 ALPINE 120100 70.2% 7. Reinjected FIORD 120120 9. 5% 9,956 NANUQ 120175 0. 7% 8. Flared or vented 1 hour or less NANUQ - KUPARUK 120185 13.5% 5,425 QANNIK 120180 0. 7% 9. Flared or vented more than 1 hour (see instr.)OTHER 5. 3% 12,295 10. Pilot and Purge 450, 775 100.0% 11. Used for lease operations (specify in Remarks) 12. Other (see instructions)Authorization >1 hr. Safety sT MCF 4,077,339 13. TOTAL VOLUME (ITEMS 6 - 12)MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from:4------m - Commissioner Date 17. Transferred to: (Express as a negative #) 18.. Remarks: I hereby certify that the regoing is tru and rrect to the best of my knowledge. Note: Al! volumes must be corrected to Signature 1 tic Titie Supervisor, Revenue 8 Regulatory pressure of 14. 65 psis and to a 9 /B)(4/ 3, 5;23Date /if 2 /2&18 temperature of 60 ° F. Authority 20 Printed Name Julie Sale Phone 11Ar95 945 Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Superseded, save flaring CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Sep-08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 9/16/ 2008 6:35 - 8:13 5,425.00 Instrumental malfunction UNPLANNED Reduced inlet rates; Restarted C -33012 Total Flare > 1 Hour 5,425 Total Flare <= 1 Hour 9,956 Pilot and Purge 12,295 Total Flare 27,676 Sep 17 2008 12:28PM HP LASERJET FAX p. GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA, INC. FACILITY ,-... 1 AIR PERM(T NUMBER n e 7. c: GAS DISPOSITION Date of Occurrence: •9118/ 2008 Flare Vert Time of Occurrences mm/dd/y0 Check Selection)00_ 00 24:0D Minutes Fran:18: 15 To: 20: 13 01: 38 Total Volume Flared or Vented:5425 MSCF BBLS From:To: Planned Unplanned O From:To: From:To: __ _ • Meter y _M R 35017's =- ? ::(:Qty Feei¢ly) =; .Total Mbytes Flared or Vented 01: 38 Includes volume flared which generated black smoke, if applicable) A. Dperip8on of Incident and Cause: (Check as marry as needed to fully describe the incident) SIO T/C:a for Procssa upeel In TIC SD duets high exhaust lempereture section of fealty EMERGENCY SHUTDOWN Flaring for dr0isite shutdown /startup J Electrical 1 Instrumentation malfunction Flare system testing EzcesaNehnsur(elent inlet gas rotes ttto facility Faulty shutdown on Faenty Mabtenance WO on high vibration Other. Comments: Faulty temperature probe on 93 bearing of C -33012 caused a turbine shutdown resulting in the flaring of oas. 6. Action Taken to Eliminate Cauca and Prevent Recurrence: ( Cheek and assombe ae applicable) J Started / restarted T/C 0 C -33012 Stabilized facility process and opera0on Compressor l train dopreseured Repaired equipment diffiadties J Reduced 1 Increased Inlet as rates with COmpletad flare (eating Facility maintenance completed J Corrected Eat fluctuation /failure Other Comments: Reduced Inlet rates, corrected problem ( swapped to spare temperature probe), restarted C- 33012. C. Flaring or Vending was: (Check one). El necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessary to prevent loss of ultimate recovery Venting Incident Was the volume over 1,000 mscf?Yes: No: 0 If Yee, complete form & contact Environmental immediately) Flare Incident TRUE Did Incident last for longer than 1 hour? Yes 0 No U yea, face this report to Environmental wIdthe 24 hours at KRU- 659-7712 or ALP at 670 Did event cause black smoke* = 3 minutes In 1 hr or 8 consecutive minutes?Yes: .0 No: it Yee, contact Env •mental Immediately KRU a59 -7242 or ALP 1170. 4200 and fax this report to Env it KRU- 650 -7712 or ALP at 670 -4607 Black smoke' emitted from source:enter tag number and description) Date and &met t black smoke° event:Front:To: Volume flared which generated black smoke':MSCF BBLS Description of step b minimize emissions: (Section B above) Material flared:Gas:d NGLs:Other. General Weather Air Temperature 37 F Wind Speed/Direction: 24 mph / East Observation by Non - Certified Visible Emission Observer Based on information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this document are true, accurate and complete. t / J! ,,/ Facility Supervisor Date 1 ! 7 / f .l Alpine: Fled Environmental Compliance Coordinators, ALP -14 Kuparuir Field Environmental Comptance Coordinators, NSK- 61 Printed 9(17/2003 9 Drive/Alpine OperatonsiFSrms /Get Flung or Verlrg e STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3, Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY ColviPe River Unit CONOCOPHILLIPS ALASKA, INC.September-08 Disposition Volume MCF 20. For productkm from multiple pools, fist contribution of each pool as a percent of Total 50, 34:Volume. 6. Sold Pool Name Pool Code Percent 3,548,540 ALPINE 120100 702% 7. Reinjected FIORD 120120 9. 5% r NANUQ 120175 0_ 7% 8. Flared or vented 1 hour or less NANUQ-KUPARUK 120185 120180 0. 7% 13.5% 9. Flared or vented more than 1 hour (see instr.)11=i QANOTHERKIK 5• 3% 10. Pilot and Purge 12,295 450,77 100.0% 11. Used for lease operations (specify in Remarks) f.: ; -.r).."*"'";; - '';''' 12 Other (see instructions)Authorization >1 hr MCF 9442Cr26 13. TOTAL VOLUME (IT8VIS 6-12) Safety4,077,33* MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from:472i3i-.441_,... Slee..1 c 17. Transferred to: (Express as a negative #) Commissioner Date 18. Remarks: r i'; 41 * IL , 1/ 4 4 ' r )1 t' _ 4.,-- - qi,- ,,, , g''' ' - . !I• t:0' I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to SignaturTitte Supervisor, Production & Revenue Accounting pressure of 14. 65 psia and to a temperature of 60 Authority 20 Printed Name Dawn Thomas Phone 263-4203 Date t 0 - t 5 - "?...40G AArPc 916 Form 10422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Sep -08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 9/16/ 2008 6:35 - 8:13 5,425.00 Instrumental malfunction UNPLANNED Reduced inlet rates; Restarted C -33012 Total Flare > 1 Hour 5,425 Total Flare <= 1 Hour 5,425 Pilot and Purge 12,295 Total Flare 23,145 Sep 17 2008 12:28PM HP LASERJET FAX P -2 GAS FLARING or VENTING REPORT - CONOCOPHILLIPS ALASKA INC, M f I tl III {it !.r > 5'i i - FACILITY,`' ,,n u .AIR PERMIT NUMBER igl GAS DISPOSITION Date of Occurrence: 9/16/ 2009 ID Flare vent Time of Occurrence: mm/dd/yy)Check Selection)OD_00 24: 00 Minutes From:111:38 To: 20: 13 01: 38 Total Volume Flared or Vented:5425 MSCF BBLS From:To: Planned Unplanned 0 From:To: Meter _f4o .: MT 50 .... :Fa From:To: R-35 }2 " `i +: ` :!(, By: Faci(l1y) ;..Total Minutes Flared or Vented 01: 38 includes volume flared which generated black smoke, if applicable) A. Description of incident and Cause: (Check as marry as needed to fully describe the incident) S/D TIC*for Process upset in T/C SD due to high exhaust temperature section of fecilty EMERGENCY SHUTDOWN Flaring for drtlleite shutdown / startup Electrical 1 instrumentation maaunctton Flare system testing Excesshre/Insuffele(t iNel gas rates Y1to fadtity Faulty shutdown on Facility Maintenance SID on high vibration Other. Comments' Faulty temperature probe on #3 bearing of C -33012 caused a turbine shutdown resulting In the flaring of gas. 8. Action Taken to Eliminate Cause and Prevent Recurrence: (Check and desOnibe as applicable) Started / restarted TIC #C -33012 Stabilized facility process and operation Compressor 1 train depressu red Repaired equipment difficulties J Reduced 1 Increased Inlet gas rates with Completed flare testing Facility maintenance completed d Corrected Sill fluduat ion /'failure Other: Comments: Reduced inlet rates, corrected problem (swapped to spare temperature probe), restarted C- 33012, C. Flaring or Vending wee: (Cheek one). 0 necessary for facility operations, repairs, upgrades, or testing procedures an emergency that threatened life or property necessary to prevent loss of ultimate' recovery Venting Molded Was the volume over 1,000 mscf9 Yes: 0 No: If Yee, complete form & contact Environmental immediately) flare Incident TRUE Did incident last for longer than 1 hour? Yes 0 No if Yee, flu this report to Environmental within 24 hours at KRU 659 - 7712 or ALP at 870.4507 Old event Gauze black smoke" > 3 minutes In 1 hr' or 6 consecutive minutes?Yes: ,Mo: ItYes, contact EnvlroritenteJ Immediately KRU 1359 -7242 or ALP 870 -4200 and fax this report to Env at KRU 659 -7712 or ALP at 670 -4607 Black smoke' emitted from source:enter tag number and description) Date and time of black smoke" event:From:To: Volume flared which genereteo black smoke':MSCF BBLS Description of steps to minimize emissions: (Section B above) Material flared:Gas:4 NGLs:Other. General Weather Air Temperature:37 F Wind Speed/Direction: 24 mph 1 East Observation by Non - Certified Visible Emission Observer Based on information and belief formed after reasonable inquiry, I certify that the statements and information in and attached to this document are true, accurate and complete. Facility Supervisor Date 9 /17/0 E o Alpine_ Field Environmental Compliance Coordinators, ALP -14 Kuparuk: Field Environmental Compliance Coordinators, NSK. 61 1 Printed 9fl7 2OOe S Drlve/Alpine Operations /Form s /Gas Flaring or Naming 1 Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility October-08 Percent 88.9% 9.4% 0.6% 1.0% 100.0% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 51,954 Pool Name Pool Code 7. Reinjected 3,325,926 ALPINE 120100 FIORD 120120 8. Flared or vented 1 hour or less 3,997 NANUQ 120175 NANUQ-KUPARUK 9. Flared or vented more than 1 hour (see instr.)2,626 QANNIK 120180 OTHER 10. Pilot and Purge 12,353 11. Assist Gas 12. Fuel gas used in lease operations.474,630 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)3,871,486 Lease Use Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner Date:May 20, 2016 Gas sold to Alpine Transportation Company = 47,137 Gas gifted to Village of Nuiqsut = 4,817 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Oct-08 VOLUME PLANNED DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 10/23/2008 7:03 - 11:22;13:13 - 14:24 2626 Faulty Shutdown UNPLANNED Replaced Quadlog Critical Discrete Module; Restarted C-33012 Total Flare > 1 Hour 2,626 Total Flare <= 1 Hour 3,997 Pilot and Purge 12,353 Total Flare 18,976 Rev 1. 12 May 16 r STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC.October -08 Disposition Volume MCF 20. For production from multiple pools. list contribution of each pool as a percent of Total 51,985 Volume. 6. Sold Pool Name Pool Code Percent 3,668,895 ALPINE 120100 68.7% 7. Reinjected FIORD 120120 9. 2% 8. Flared or vented 1 hour or less 3,997 NANUQ 120175 0. 6% NANUQ- KUPARUK 120185 13.5% 9. Flared or vented more than 1 hour (see Instr.) 2,626 OTHERO 120180 1. 0% OTHER 6. 9% 12,353 10. Pilot and Purge 474, 630 100.0% 11. Used for lease operations (specify in Remarks) 1 12. Other (see instructions)z ` I` w, :..::_' ' Authorization >1 hr.MCF 4,214,486 Safety 2 VA4 13. TOTAL VOLUME (ITEMS 6 - 12) Lease Use MCF 14. NGL Gas Equivalent Conservation MCF 15. Purchased gas Waste:MCF 16. Transferred from:2- - 3 - DT Commissioner Date 17. Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the oregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to Signature fit.fi(, /Title Supervisor, Revenue and Regulatory pressure of 14. 65 psia and to aTr Printed Name Julie Sale Phone (91 B) 661 -3523 Date 19/ 20,09 temperature of 60 ° F. Authority 20 9A5 Form 10-422 Rev, 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Superseded, save flaring CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Oct-08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 10/ 23/ 2008 7:03 - 11: 22; 13: 13 - 14: 24 2626 Faulty Shutdown UNPLANNED Replaced Quad log Critical Discrete Module; Restarted C-33012 Total Rare 1 Hour 2,626 Total Flare <0 1 Hour 3,997 Pilot and Purge 12,353 Total Flare 18,976 GAS FLARING or VENTING REPORT - CONOCOPHILLtPS ALASKA, INC. FACILIT - AWitle AIR PERMIT NUMBER • 489TVPIN GAS DISPOSRION Data of Occurrence:10t23i2GO8 CI came Overt 7.100 0j Orarrretree_ krynkidAir)Check Selection)Mg teantts From:0T:03 To: 1122 04 :19 Total Volume Ftahed or Venial:MO taco'MRS Rom:1343 TO 1444 01: 11 Flaunted Unplanned C7'rrom:to: FtrattK To: III Motet No PA7R45O t2 By Facility)Total Npn WuleeRIM orVontvd 06 0 Includes *Donna Mated whidt gonoratod buds smoke, f ft. Deeenpllon of et and Coate. {Cheat ea rummy es needed to hull{ dmeribei the inddemt Wit:CB*ono y tow _ _ /'' y Pmceet Wool to wrrww,w•w TC SD tSoh **oust lotnitotatoto lootilon of fancy F MT:EMMYS1BJ TC O N nem toe d011sito ottutdoan i Oastop 8lecIrlOP r bottioutoototion maes>nodau flew PirOoarteaiing Escerteleoinsurikleotireotoos mew Imo fed*x l tnJysta,Mfeaet an oft c rtmeriis FseG[y A nw SJD on hgh vkuetion Ulu:r ConbJ>mrits: A •t,which i$a.cfiikal - • u, Mae Sa,.,, his 4.;... u. fa .'.Ina..: ace. ahodoo110fthe .Fr i,.A.:u,y_ et • genetatfonl. The Perim a owed Mstatt of the fitc22 . 8. Mallon Talton to Sladnats Copse cad Prewat Rewumtwx {Glexk And dewuare as applicable) X Started r rastarled TIC d 043012 {HP lntection Comprsgeor)Stababred fociaty prOcttss ertd Operation Compressor. l train depresswed Repaired equiptnoittdfIcukdee ROduuaso t 1M:rested inlet gasy odes itith Completed flare feeling Facility msdn;eflaraoe a> eJarJ Corrected Eli fiuchta5r n i failure Odin: Corrnn * The Quadrat Crdical Oktcrotes AtocAJle sass replaced to allow the facility to be restarted. The card yea be lent bads to the manufacturer flx etsedysisto determine) if the cause Of Ma WW1 is lsa tta dt Cancel) he pmeverded in the future The d u ra tion of the 8erin0 was longer then normal Rs a ridgy rest t becrxtaeeite of the e:MinN *vela ba the gas OPPV#1 /101 open and had tabtrepaired Fl ar ing rj inmeteary for away operations. emirs, upgrade& ortessag pmcod ures 0 an emergency gel threatened life or property 0 nem - -, w•ritima a las f E Vent Ineidaett Wait the volume over 1,000 atscf2+Yves: No: 0 of Yes. Coy ids form 8 *meet Environmental unedlatoty) o Flare Incident TRUE Oki incident tastier longer men 1 tour? Yea I No 0 If Yes, fax this report to Environmental within 24 hours at mu- ist&rry or ALP at 670-4507 Oki event cause black stroke" a 3 minutes in 1 hr orb constitutive minutes'i> l ?Yes; No Cl 0Yes, ggrod.ggykggigaglimmagiglak K1tI4S9-7242 or ALP 8io• 4ioo and fax this report to Env st MU- GM-TM or ALP:at11Wd807 stack *molts' meted tom source:ender tag number ash deyscrittcn) Me and tine of black smoke" stank Prom:To: Velumo hated OM) getwated black smoke=SWF CMS Dettorkidon of steps to minkn1agt entissions: (Section 8 Ste) Materiel hared:Oat:X NEL$'.Other: Genial Wearier:Air 7emperauuse: , IS deo F Whet n: 20 no cut of th a NE Observation , • Nome i! to Endasron Observer Bated on k ionhalon and beNet fanned Oar tea t y 1 CerSfyy shat the sistemenis and Information in end ed ro this deco mlentafe titre. accurate and Y9 Facility Supervisor Dade i 6112 -3/ 41 V 4 cc Alm: Reid Endronsneritst comptiancecotarnetora, ALP-f4 Kupaaic.lgeid Environmental Compaance ooeramtatots. WOK- 81 1 rkialr;I 14 re8euat»+? Opezraxxcr:aert3as f1Afi'18 or vcr, ms Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility November-08 Percent 88.0% 9.2% 1.1% 1.7% 100.0% MCF 19. Remarks: STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20.For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 47,785 Pool Name Pool Code 7. Reinjected 3,185,471 ALPINE 120100 FIORD 120120 8. Flared or vented 1 hour or less 10,252 NANUQ 120175 NANUQ-KUPARUK 9. Flared or vented more than 1 hour (see instr.)11,101 QANNIK 120180 OTHER 10. Pilot and Purge 13,799 11. Assist Gas 12. Fuel gas used in lease operations.477,591 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)3,745,999 Lease Use Date MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner Date:May 20, 2016 Gas sold to Alpine Transportation Company = 42,850 Gas gifted to Village of Nuiqsut = 4,935 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Printed Name:Diane Hendrickson Phone:(918) 661-7897 Flaring approved on original. Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Nov-08 VOLUME PLANNED DATE TIME (MSCF)DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 11/11/2008 7:42 - 14:46 11101 Electrical/ Instrumentation malfunction UNPLANNED Corrected E&I fluctuation/ failure Total Flare > 1 Hour 11,101 Total Flare <= 1 Hour 10,252 Pilot and Purge 13,799 Total Flare 35,152 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION 1 FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2, Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1030000017 ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC. i Novem.,e-06 Disposition Volume MCF 20. For production from multiple pools, fist contribution of each pool as a percent of Total 47,811 Volume. 6. Sold Pool Name 1 Pool Code Per 1t 3,6113,146 1tlNE 1 4310 4%' 7. Reinjected FIORD 120, 10,252 NANUQ l'.?.:A751 8. Flared or vented 1 hour or less NANUQ-KUPARUK 11,101 QANNIK 9. Flared or vented more than 1 hour (see Instr.)OTHER 1 10. Pilot and Purge 13,799 1 11. Used for lease operations (specify in Rema 477, 590 i EffrYIFTK- 1,74,PAP,CliTia 12. Other (see instructions)Authorization >1 hr: ty Id 0 13. TOTAL VOLUME (ITEMS 6-12) 4,178,699 Safe t 4--IVIIT - i Lease Use 14. NGL Gas Equivalent IMC,FConservation i 15. Purchased gas 4---- -- - :Waste:i MCF 16. Transferred from: Commissioner Date i 17. Transferred to: (Express as a negative #) 18. Remarks: I hereby certify that the f9rgoing is true a rrect to the best of my knowledge. 1 r Note: All volumes must be corrected tO Signature J .0 Title Supervisor, Revenue & RequlatorV pressure of 14. 65 psia and to a temperap ire of 60 Adthor ,:,, 2r Printed Name Julie Sale Phone (918) 661-3523 Date Lilekdd g AAC 2' R. Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Box's 6, 7, 11 and 20 revised CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Nov-08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE 11/ 11/2008 7:42 - 14: 46 11101 Electrical/ Instrumentation malfunction UNPLANNED Corrected E &I fluctuation,' failure Total Flare > 1 Hour 11,101 Total Flare <= 1 Hour 10,252 Pilot and Purge 13,799 Total Flare 35,152 ft to -: air-( 6 GAS FLARING Or VENTING REPORT - CONOCOPHILUPS ALASKA, INC. FACILITY - Alpine AIR PERMIT NUMBER . 4897NP01 GAS t7t5PQSIT1t3N Date of Occurrence:1111112008 ,0 mare Dean Time of Occurrence: mnNddiyy)Cherie Selecfioh)00: 00 224_00 uasa,ts u From:07 :42 to: 44; 48 tt irr4I4 Total Volume Flared or Vented it IO1 1 MSCF 6815 From To: Plowed Unplanned LI Prom:To: From:To:2. deter No bait-30012 8y Faclay)Total Mtatdes Flared or Veined m 07x)0 includes volume fared which generated black smoke. If am/matte)J A Oastrlplion of tnddeM and Cass* (Chock as many as needed to tuft' describe Ma tnetdent) Sal WI for Prepays !evader TX SO dug to MO ei4 iI tarrgerstu+o meson of me* EMERGENCY SHUCDOWN Florin rereb1Hdie ettutdaan $ stash X Eleceind Jtestnencrtteden rrieltunudrrn Fiero *ste n basting Exeessiveleadeoltra We* gas rates Into tech y Faulty Shutdown on Fees, Mainkznface Other. t.P en:premier pals was tared durfng the period required to troubleshoot ui problett gavotss t> im tree LP compressor , • being re sher a rp. possible mechanical, Instrumentation and process issues were mated leading to to discovery of a tailed ktrtd trammeter on the iP_ celtpr car Irani thatwa8 the same of the restart problems. yeas gas Gem Me LP system rrcm the NP syintem Caused *Wilted texitioeptietmerat hi rite LP eornpmeior. in izd lust phase oftroubleshooting, operators and engineers determined that the LP aompressoe , a surge co n tr o l syste m drag t to t , tel o + rob rg tae yeti pressor to start due to elevated sucpon p l atsm * . Operators went tuough normal pmCe lees Irt an attempt *lower tho suction mature t!y wniptaa8ng temperatures and preiedare Coeltror8r8. When Maio eonsprowed llosuocellehd a Second mold Of ttoubieshootio0 Woo required that led to.ON* oe gas blow by end Med lasinsment Scene 04 prvdUCt160 Was • cuddled lo miairrliae flarir4 B. Action Taken to Etlmtnato Cause and Prevent Rectum= (Cheek mid describe as *Ousels, Started J restarted T/C S Stohi lzod faddy process snd.operaU0n Compressor /train deprisaunfd RePaltedequtpmentditl1Cttdea Reduced /i creased inletgee rates with Completed tares testing Faetity mabrtenance oomplebsd x Corroded Edt 4wetration J failure taer: 0121.1 Seetepact the 1 st stage knodtout drams levy a ctni roI to the spare Mod transmater n the result Tire Bed trans l bat rttpaxed or as rttwo9sary. Adt8onat !dawns and!cr nod matons are being kwrestigated to alertoperators to the tared levet iranersii#er. C. flaring or Venting was; (Check ono) E1 necessary *r facility operations. repairs. upgrades. or testing procedures ors emergency meat threatened ate or properly neeassar' a prevent lass of u twnae reoav7 Venting. Incident was the volume over 1,000 mscf?Yes: 0 No: If Yes, complete loran A .contact Environmental immediately) Flare Incident TRUE i Did bxfdant last for longer atan 1 hour? Yes []No If Yes, tai t1de report to Environmental within 2+ hours at KRU- 859.7702 or ALP et 670 -4507 Did truant Onset black smoke' > 9 minutes In 1 hr et 0 censedutive alkalies?Ys5 fl No: El If Yes. AgilfgetraltkidlitALLIWOOMMtgly KJIU 859 -7242 or ALP 670-4200 and fax ibis report to Env at KRU- 659.7712 or ALP at 070 Blackamoke" exnitkad rrore source;enter lag number and description) Oa and Sete of black dinette* event From 7o: Volta* flared which generated hiss* mocha':MSCF 8BLS Desidipuon orsteps a minimize emissions: (Section B above) Material awed:Gas:x Neu:Other General Weather:Air /my perahro :.15 deq F Mind Seeed/Dresden: 27 mph out otttfe NE Obsetva8on by Afcrl:Certrfled Visible Emission Observer Based on Information ertd belief formed akar reasonaaxt heir! d -:: :ay mra: the statements and infemtmtien in and attached to this docurront aro hue, accurate and. - e. Facility Sup 7,,.,,Data rJ cc: Alpine: Field Environmental Comptlonoe Coordmatois, ALP -14 i' .' KlrpanjY: REM Environmental ComplianceCoexdnators. NSI(- 61 Prxaditit2109a srdrcuei -ip isoftisdla ct;MO'- !G.: Ftu'r , ,,^ Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 2. Facility Name 1030000017 Colville River Unit Processing Facility December-08 Percent 87.7% 8.9% 1.0% 2.3% 100.0% MCF 19. Remarks: May 20, 2016 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 3. Field 4. Operator 5. Month/Year of Disposition Colville River Unit CONOCOPHILLIPS ALASKA, INC. Disposition Volume MCF 20.For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 49,576 Pool Name Pool Code 7. Reinjected 3,285,809 ALPINE 120100 FIORD 120120 8. Flared or vented 1 hour or less 3,926 NANUQ 120175 NANUQ-KUPARUK 9. Flared or vented more than 1 hour (see instr.)0 QANNIK 120180 OTHER 10. Pilot and Purge 13,365 11. Assist Gas 12. Fuel gas used in lease operations. 489,802 13. Other (see instructions)Official Use Only Authorization >1 hr:Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)3,842,478 Lease Use Date MCF 15. NGL Gas Equivalent MCF 16. Purchased gas Waste: 17. Transferred from: 18. Transferred to: (Express as a negative #)Commissioner Gas sold to Alpine Transportation Company = 44,246 Gas gifted to Village of Nuiqsut = 5,330 I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature:Title:Revenue & Regulatory Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60 o F. Authority 20 AAC25.235.Diane Hendrickson Phone:(918) 661-7897 Date: Rev 1. 12 May 16 CONOCOPHILLIPS ALASKA, INC CONSERVATION ORDER NO. 443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Dec-08 START END PLANNED VOLUME DATE TIME DATE TIME UNPLANNED (MSCF)DESCRIPTION OF FLARING EVENT ACTION TAKEN TO MINIMIZE VOLUME Total Flare > 1 Hour 0 Total Flare <= 1 Hour 3,926 Pilot and Purge 13,365 Total Flare 17,291 Rev 1. 12 May 16 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator Month/Year of Disposition 1030000017,ALPINE PROCESSING FACILITY Colville River Unit CONOCOPHILLIPS ALASKA, INC. 15.December -08 Disposition Volume MCF 20. For production from multiple pools, list conbibution of each pool as a percent of Total 6. Sold 49,607 Volume. Pool Name Pool Code Percent 3,871,780 ALPINE 120100 66.0%7. Reinjected FIORD 120120 8. 9% 3,926 NANUQ 120175 1. 0%8. Flared or vented 1 hour or less NANUQ- KUPARUK 120185 13.8% 0 QANNIK 120180 2. 3%9. Flared or vented more than 1 hour (see Instr.)OTHER 8. 0% 10. Pilot and Purge 13,365 489, 802 100.0% 11. Used for lease operations (specify in Remarks) 12. Other (see instructions)Authorization >1 hr : ty MCFSafe4,428,48C13. TOTAL VOLUME (ITEMS 6 -12) MCF Lease Use 14. NGL Gas Equivalent MCF Conservation 15. Purchased gas Waste:MCF 16. Transferred from: 17. Transferred to: (Express as a negative #) Commissioner Date 18. Remarks: I hereby certify that the fo . oing is true and co to the best of my knowledge. Note: All volumes must be corrected to Signature a Title Supervisor, Revenue & Repulatory pressure of 14. 65 psia and to a temperature of 60 Authority 20PrintedNameJulieSalePhone (918) 661 -3523 Date h* 1c2 AO AA(175 2:4q Form 10-422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate SUPERSEDED CONOCOPHILLIPS ALASKA, INC, CONSERVATION ORDER NO.443 ALPINE ALPINE PROCESSING FACILITY GAS FLARING INCIDENTS Dec-08 VOLUME PLANNED DATE TIME MSCF) DESCRIPTION OF INCIDENTS & CAUSE UNPLANNED ACTION TAKEN TO ELIMINATE CAUSE Total Flare > 1 Hour 0 Total Flare <5 1 Hour 3,926 Pilot and Purge 13,365 Total Flare 17,291 SUPERSEDED