Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutDIU Endicott Gas DispositionState of Alaska AOGCC Gas Disposition Files Year: 2014 Facility: DIU Endicott Operator: BP EXPLORATION (ALASKA) STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. MonthfYear of Disposition I Jan -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 55,028 Pool Name Pool Code Percent 7. Reinjected 10,306,865 Endicott 220100 96.31% Sag Delta 220150 0.05% 8. Flared or vented 1 hour or less 19 Eider 220165 3.53% Minke Tract Op 220170 0.11% 9. Flared or vented more than 1 hour (see instr.) Q 100.00% 10. Pilot and Purge 10,199 11. Assist Gas 21,476 12. Fuel gas used in lease operations. 1,048,050 13. Other (see instructions) Use Onlyons) Authorization >i hr: Safety MCF 14. TOTAL VOLUME(ITEMS 6-13) 11,441,637 Lease Use MCF 15. NGL Gas Equivalent 54,050 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that the foregoing is true and correct to the best of my knowledge. �/� Manager, Production Taxes and Royalties Note: All volumes must be Signature CLSt Title Alaska corrected to pressure of 14.65 psia f and to a temperature of 60o F. Printed Name Diane Colla Phone (907)564-5775 Date / I Authority 20 AAC25.235. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operatof BP 5. Month/Year of Disposition Feb -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 46,532 Pool Name Pool Code Percent 7. Reinjected 9,191,725 Endicott 220100 97.23% Sag Delta 220150 0.07% e. Flared or vented 1 hour or less 157 Elder 220165 2.59% Minks Tract Op 220170 0.11% 9. Flared or vented more than 1 hour (see insir.) 0 100.00% 10. Pilot and Purge 9,212 11. Assist Gas 19,150 12. Fuel gas used in lease operations. 948,011 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6.13) 10,214,787 Lease Use MCF 15. NGL Gas Equivalent 46,141 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner Date 16. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Manager, Production Taxes and Royalties Note: All volumes must be vw�Signature_ Title Alaska corrected to pressure of 14.65 psia and to a temperature of 60o F. Printed Name Diane Cole Phone (907)564-5775 DataAuthoritv 20 AAC 5.23 . iJ1A1J STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. MonthNear of Disposition I Mar -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. e. Sold 50,009 Pool Name Pool Code Percent 7. Reinjected 9,890,821 Endicott 220100 97.06% Sag Delta 220150 0.08% 8. Flared or vented 1 hour or less 15 Elder 220165 2.75% Minke Tract Go 220170 0.11% 9. Flared or vented more than 1 hour (see instr.) 0 100.00% 10. Pilot and Purge 10,199 11. Assist Gas 21,220 12. Fuel gas used in lease operations. 1,045,108 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 11,017,372 Lease Use MCF 15. NGL Gas Equivalent 48,779 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner Date 18. Transferred to: (Express as a negative #) 19, Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Manager, Production Taxes and Royalties F Note -.,.fl volumes must be Signature �CVr11 Tide Alaska corrected to pressure of 14.65 psis V and to a temperature of 60o F. Printed Name Diane Colley Phone 907)564-5775 Date / C2 ,219 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. MonthNear of Disposition I Apr -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. s. Sold 29,665 Pool Name Pool Code Percent 7. Reinjected 6,589,055 Endicott 220100 97.31% Sag Delta 220150 0.05% B. Flared or vented 1 hour or less 1,274 Eider 220165 2.56% Minke Tract Op 220170 0.08% 9. Flared or vented more than 1 hour (see instr.) 2,960 100.00% 10. Pilot and Purge 9,870 11. Assist Gas 21,464 12. Fuel gas used in lease operations. 850,411 13. Other (see instructions) Official Use Only Authorization hr: Safety Z / �O r� MCF 14. TOTAL VOLUME (ITEMS 6.13) 7,504,699 Lease Use MCF 15. NGL Gas Equivalent 28,226 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: / 21 (4( Co issioner Date 16. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that t//thh���e foregoing is true and correct to the best of my knowledge. �� �/�/(/�„� Manager, Production Taxes and Royalties signature �/ Title Alaska Printed Name Diane Colle Phone (907)564-5775 Date y / Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authoritv 20 AAC25.235. BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Apr -2014 UAL= I TwjG cfL'a mr inar, Ur %NIUMR t-* IAVpc, TOTAL 970 Not required for unplanned events which Not required for unplanned events which are less than or equal to I hour are less than or equal to 1 hour 1Unplanned Events greater than 1 hour 183 DATE TIME VOLUME .......... .... .. ...... ... . .. C 4/19/2014 2055-2203 84 Ist stage separator high pressure trip MPI & SDI wells shut in 4/2012014 0000-0315 89 Booster compressor down Start Booster compressor 4/2012014 1343-1508 64 Booster compressor down Start Booster compressor 4/25/2014 1324-1457 46 Booster compressor down Start Booster compressor 4/25-2612014 1623-0720 846 B main compressor tripped Start B main compressor 4127/2014 1347-1859 149 Booster compressor down Start Booster compressor 4/282014 1454-1729 79 Propane turbine given a start Propane turbine on line ............... - , o �,X TOTAL 1,357 V- ON SUMM IPlanned Events less than or equal to 1 hour DATE TIME VOLUME �': ' UIMIN ... . ...... TOTAL 304 Not required for planned events which Not required for planned events which are less than or equal to I hour are less than or equal to 1 hour 4/16-1712014 2255-0226 183 Shutting down A main for water washes Shut in wells to make up for loss of A main 4/2012014 0340-1328 321 Starting A main gas compressor Started A main and closed copus starting gas 4/2112014 0604-2130 1,045 B main shut down and depressured Depressure and close vent valves 412112014 2131-2329 54Booster 1,603 compressor down Start booster compressorTOTAL V/ A IPA ............... - , o �,X M NKE ........ ............. ..... ON SUMM Volume flared less than 1 hr 1,274 33 1 0 1,240 Volume flared greater than 2,960 ✓ 76 2 2 2,880 1 hr Pilot Purge 9,870 253 8 5 9,604 Assist Gas 21,464 550 17 11 20,886 TOTAL FLARED VOLUME 35,568 9112 28 is 34,610 517/2014 1 of 1 Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Monday, April 28, 2014 3:17 PM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D Subject: Endicott Flaring Summary April 19-27, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of several planned and unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of necessary maintenance on the "A" Main compressor, "B" Main compressor, and booster compressor. Summary of planned flaring events: 20 -Apr -14 3:40 (588 minutes, 321 MCF) 21 -Apr -14 6:04 (926 minutes, 1,045 MCF) 21 -Apr -14 21:31 (118 minutes, 54 MCF) Summary of unplanned flaring events: 19 -Apr -14 20:55 (68 minutes, 84 MCF) 20 -Apr -14 0:00 (195 minutes, 89 MCF) 20 -Apr -14 13:43 (85 minutes, 64 MCF) 25 -Apr -14 13:24 (93 minutes, 46 MCF) 25 -Apr -14 16:23 (457 minutes, 457 MCF) 26 -Apr -14 0:00 (440 minutes. 389 MCF) 27 -Apr -14 13:47 (312 minutes, 149 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Ken Miller AK, HSSEE Environmental Advisor North W (907)659-6810 Pager 659-5272, #4313 Harmony (907)659-6441 Alternate: Rich Vicente STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number T. 0290000002 Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. Month/Year of Disposition I May -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 41,241 Pool Name Pool Code Percent 7. Reinjected 9,018,583 Endicott 220100 99.31% Sag Delta 220150 0.06% e. Flared or vented 1 hour or less 52 Eider 220165 0.50% Minke Tract Op 220170 0.12% 9. Flared or vented more than 1 hour (see instr.) 374 100.00% 10. Pilot and Purge 10,199 11. Assist Gas 22,033 12. Fuel gas used in lease operations. 999,000 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety 3 � MCF 14. TOTAL VOLUME (ITEMS 6-13) 10,091,482 Lease Use MCF 15. NGL Gas Equivalent 40,993 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: n / Comm sinner Date 16. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that the foregoing is true and correct to the best of my knowledge. n, v Manager, Production Taxes and Royalties Note: All volumes must be Signature (7/ Title Alaska corrected to pressure of 14.65 psia J and to a temperature of 60o F. Printed Name Diane ColleyPhone (907)564-5775 Date ( tv 20 AAC25.235. ✓�h BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT May -2014 Unplanned Events less than or equal to 1 hour PATE TIME t10$ IPTtOt �iF:.I.N0i4i $`GWSA 4GTiQt4iAKENTE7$11NII.MRiE}<At3BE;; TOTAL 52 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTtONUF.it�CkDENT&;CAUSE ACTI.ONTAKENTOELIMC( YEC11Lk&E 5/1912014 1205-1523 374 Booster compressor shut down Restart booster compressor TOTAL 374 Planned Events less than or equal to 1 hour DATE TIME- UN.4LUMEDE CRIPTK3N OF;INCkDENT &;(SAt33E ACTION TAKENTO EL{MINATE TOTAL 0 Not required for planned events which Not required for planned events which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events greater than 1 hour DATE TIME V07UME:. DESD'.:.I. W .: 'mmusE. A :-: , ,. :: LI :,: CAUSE TOTAL 0 fiOTAL EIDR NIhIK�QOTT Volume flared less than 1 hr 52 0 0 0 52 Volume flared greater than 374 2 0 0 372 1 hr Pilot Purge 10,199 51 12 6 10,130 Assist Gas 22.033 111 27 13 21.882 TOTAL FLARED VOLUME 32,658 164 39 19 32,436 6/4/2014 1oft Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Wednesday, May 21, 2014 12:48 PM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech, AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D Subject: Endicott Flaring notification May 19, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of one unplanned flaring event of greater than one hour which occurred at the Endicott Production Facility. This event was the result of a shutdown of the booster compressor due to a mechanical failure. Summary of unplanned flaring event: 19 -May -14 12:05 (196 minutes, 374 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Ken Miller AK, HSSEE Environmental Advisor North W (907)659-6810 Pager 659-5272, #4313 Harmony(907)659-6441 Alternate: Rich Vicente STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. MonthNear of Disposition I Jun -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 31,143 Pool Name Pool Code Percent 7, Reinjected 8,934,331 Endicott 220100 99.64% Sag Delta 220150 0.04% 8. Flared or vented 1 hour or less 180 Eider 220165 0.20% Minke Tract Op 220170 0.13% 9. Flared or vented more than 1 hour (see instr.) 1,686 100.00% 10. Pilot and Purge 9,870 11. Assist Gas 21,519 12. Fuel gas used in lease operations. 963,031 13. Other (see instructions) Official Use Only Authodzatlon>i hr. Safe ty rP �/ MCF 14. TOTAL VOLUME (ITEMS 6-13) 9,961,760 LeE MCF 15. NGL Gas Equivalent 30,865 Co MCF 16. Purchased gas Waste: MCF 17. Transferred from: ^ I. 4 ii_3 _/ l / Com i sinner _J r� Date 4/ - 18. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Bachand, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Mn Volnager, Production Taxes and Royalties Signature /J/ Ny Title Alaska t v 000 I/.� Iq Printed Name Diane ColleyPhone (907)564-5775 Date L' i l Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAQ91; 219 YL- r g/zs h q BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Jun -2014 jUnplanned Events less than or equal to I hour DATE TIME 1,09P,"M N TOTAL 166 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour [Unplanned Events greater than I hour TOTAL EIDR...... XX, DATE TIME VOLUME xx Des"IPTIONOF 114044 WCAMg:� TORT J. _T #A Q 8/24/2014 0000-0112 10 Booster compressor off line 6/21-22/2014 6/24/2014 1144-1717 367 Plant swing due to high ambient temps Cut gas rates on wells TOTAL 377 6/22/2014 1416-2118 224 Propane compressor & booster compressor down Complete maintenance and restart lPlanned Events less than or equal to 1 hour 0436-1222 226 DATE TIME VOLUME DESCRIPTION :QrIHCIiTENTPo 'E A 0 EL!"NW, SE TOTAL 14 Not required for planned events which Not required for planned events which Complete maintenance and restart are less than or equal to 1 hour are less than or equal to 1 hour IPlanned Events greater than 1 hour TOTAL EIDR...... XX, DATE TIME VOLUME C. IRTI DES R ON WOMENT-A.-C-A E ,F TAKE ACTION N -TOWN NATUA .-A., 6/21-22/2014 1806-0422 439 Propane compressor & booster compressor down Complete maintenance and restart 6/22/2014 1416-2118 224 Propane compressor & booster compressor down Complete maintenance and restart 6/23/2014 0436-1222 226 Propane compressor & booster compressor down Complete maintenance and restart 6/23/2014 1359-1828 214 Propane compressor & booster compressor down Complete maintenance and restart 6123/2014 1846-0000 206 Propane compressor & booster compressor down Complete maintenance and restart 28 TOTAL 1,309 TOTAL FLARED VOLUME 33,255 7/3/2014 1 of TOTAL EIDR...... XX, WP AN I Volume flared less than 1 hr 180 0 0 0 180 Volume flared greater than 1,686 4 2 0 1,680 1 hr Pilot Purge 9,870 20 13 4 9,833 Assist Gas 21,519 42 28 8 21,441 TOTAL FLARED VOLUME 33,255 66 43 12 33,134 7/3/2014 1 of Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Wednesday, June 25, 2014 5:34 AM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data Coordinator North Subject: Endicott Flaring Summary June 15-22, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of several planned and unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of necessary maintenance on the propane compressor and plant swings due to high ambient temperatures. Summary of planned flaring events: 21 -June -14 18:06 (93 minutes, 33 MCF) 21- June -14 19:40 (260 minutes, 185 MCF) 22 -June -14 00:00 (262 minutes, 222 MCF) 22- June -14 14:16 (165 minutes, 9 MCF) 22- June -14 17:02 (256 minutes, 222 MCF) 23- June -14 04:36 (466 minutes, 226 MCF) 23- lune -14 13:59 (198 minutes, 162 MCF) 23- June -14 17:19 (69 minutes, 52 MCF) 23- June -14 18:46 (314 minutes, 206 MCF) Summary of unplanned flaring events: 24 -June -14 00:00 (72 minutes, 10 MCF) 24- June -14 11:44 (333 minutes, 368 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Rich Vicente BPXA Environmental Advisor North Phone (907) 659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Ken Miller STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. Month/Year of Disposition I Jul -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. sold 37,535 Pool Name Pool Code Percent 7. Reinjected 9,159,138 Endicott 220100 97.76% Sag Delta 220150 0.04% 8. Flared or vented 1 hour or less 206 Eider 220165 2.07% Minke Tract Op 220170 0.12% 9. Flared or vented more than 1 hour (see instr.) 1,638 100.00% 10. Pilot and Purge 10,199 11. Assist Gas 23,581 12. Fuel gas used in lease operations. 989,311 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety `/3 F; W MCF id. TOTAL VOLUME (ITEMS 6-13) 10,221,608 Lease Use MCF 15, NGL Gas Equivalent 36,677 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: —/ 11 Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that t//thh��te foregoing is true and �correct to the best of my knowledge. ��yjA�y� Manager, Production Taxes and Royalties Note: All volumes must be Signature (��/Ik ` �Title Alaska corrected to pressure of 14.65 psia / and to a temperature of 60o F. Printed Name Diane Colle Phone (907)564-5775 Date Authoritv 20 AAC25.235. BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Jul -2014 jUnplanned Events less than or equal to 1 hour DATE TIME DESCRIPTION OF INqQE -.T R;GAt#SE ACTION TAKEN TqgWM AV$f .. TOTAL 146 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour unplanned Eventsgreater than I hour . TX: E DATE TIME V00 A. 7/7-8/2014 1246-1218 642 Control system upset on Power Generation system Added assist gas 7/18-19/2014 0543-1350 273 Booster compressor offline/NGL plant down Propane compressor repairs in progress 7/21/2014 1144-1717 383 Rising ambient temperature Shut in well to reduce gas in system TOTAL 1,298 Pilot Purge 10,199 IPlanned Events less than or equal to I hour 13 4 DATE TIME vqLmmr WIR1110 OFINOW, Ac K F -'N TOTAL 60 Not required for planned events which Not required for planned events which 35,624 737 are less than or equal to 1 hour are less than or equal to 1 hour IPlanned Events greater than 1 hour DATE Time Vow 7/19/2014 1438- 1900 340 Booster compressor offline/NGL plant starup Start Booster compressor TOTAL 340 ....... . TX: E %X Volume flared less than 1 hr 206 4 0 0 202 Volume flared greater than 1,638 34 2 1 1,601 1 hr Pilot Purge 10,199 211 13 4 9,971 Assist Gas 23,5811 488 29 10 23,054 TOTAL FLARED VOLUME 35,624 737 44 15 34,828 81612014 1 Of 1 Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North <AKHSSEEEnvAdvNorth@bp.com> Sent: Wednesday, July 09, 2014 4:41 AM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data Coordinator North Subject: rciifFlaring Summary July 7, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of three unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of a control system upset on the facility power generation system, which required the addition of assist gas. Summary of unplanned flaring events: 7 -July -14 12:46 (73 minutes, 106 MCF) 7 -July -14 13:50 (610 minutes, 256 MCF) 8 -July -1400:00 (738 minutes, 280 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Rich Vicente BPXA Environmental Advisor North Phone (907) 659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Ken Miller Hunt Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Wednesday, July 23, 2014 4:42 AM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FielclO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data Coordinator North Subject: flaring Summary July 8-23, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of planned and unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of propane compressor repairs and well shut ins, which required the addition of assist gas. Summary of unplanned flaring events: 18 -July -1405:43 (1097 minutes, 156 MCF) 19 -July -14 00:00 (386 minutes, 60 MCF) 19 -July -1406:27 (122 minutes, 14 MCF) 19 -July -14 08:39 (311 minutes, 43 MCF) Summary of planned flaring events: 19 -July -14 14:38 (158 minutes, 161 MCF) 19 -July -14 17:17 (103 minutes, 179 MCF) 21 -July -14 09:26 (178 minutes, 383 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Rich Vicente BPXA Environmental Advisor North Phone(907)659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Ken Miller STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. MonlhNear of Disposition I Aug -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 11,567 Pool Name Pool Code Percent 7. Reinjected 9,105,890 Endicott 220100 97.68% Sag Delta 220150 0.04% 8. Flared or vented 1 hour or less 471 Elder 220165 2.16% Minks Tract Cip 220170 0.12% 9. Flared or vented more than 1 hour (see Irish.) 5,418 100.00% 10. Pilot and Purge 10,199 11. Assist Gas 23,800 12. Fuel gas used in lease operations. 954,511 13. Other (see instructions) Official Use Only Authorization >1 hr Safety i,'/f � [7 LL MCF 14. TOTAL VOLUME (ITEMS 6-13) 10,111,856 Lease Use MCF 15, NGL Gas Equivalent 11,011 Conservation MCF 16. Purchased gas Waste. MCF 17. Transferred from: sinner /y- Com i [ (/ Date 18. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. egoing is true and correct to the best of my knowledge. 1 hereby certify thaawrv@( Manager, Production Taxes and Royalties Note: All volumes must be rrected t0 pressure of 14.65 psia signature ride Alaska Fand / to a temperature of 60o F. Printed Name Diane Colle Phone (907)564-5775 Date / to20 AAC25.235. V� lo%-Hvl� BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Aug -2014 Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DATE TIME TOTAL 899 AGTICENTAgYJ"i.'�tLL411AtAt�4TECAi1S>x ;I TOTAL TOTAL 471 Not required for unplanned events which Not required for unplanned events which 1 hr 10 23247 are less than or equal to 1 hour are less than or equal to 1 hour Unplanned Events greater than 1 hour 38,962 DATE TIME VOLUMEOESLRIFTI(1i•1..E.. IL1N�`k.tst..AU&E. , itC.;'.I(1N TA1(Ei�,'.((r Bt,#Ml0A7E g.'. PSE 811/2014 0836-2030 303 Plant upset 816-7/2014 1035-0923 639 Mechanical problem with propane compressor Propane compressor repairs in progress 8/8-11/2014 1442-1755 1,607 Propane and gas booster compressors down Repairs in progress 8/18-1912014 1500-1908 312 Propane and gas booster compressors down Repairs in progress 8/19-2012014 2051 -0525 33 Propane and gas booster compressors down Repairs in progress 8/20/2014 1020-2124 56 Propane and gas booster compressors down Repairs in progress 8/21/2014 0000-0204 40 Propane and gas booster compressors down Repairs in progress 8/22-24/2014 1435-0540 1,141 Propane and gas booster compressors down Repairs in progress 8/29-30/2014 0513-0000 388 Propane and gas booster compressors down Repairs in progress TOTAL 4,519 Planned Events less than or eaual to 1 hour TOTAL 0 Not required for planned events which are less than or equal to 1 hour Ir IPI nICU [_.VGIIW YlUdtCI UIdU I nUUr DATE TIME VOLUME 8/30/2014 0000-2359 899 TOTAL 899 5,293 TOTAL Volume flared less than 1 hr 471 Volume flared greater than 5,418 1 hr 10 Pilot Purge 10,199 Assist Gas 23 800 TOTAL FLARED VOLUME 39,888 cut for TAPS slow down Not required for planned events which are less than or equal to 1 hour I 1 0 460 117 6 2 5,293 221 12 4 9,962 515 28 10 23247 863 47 16 38,962 9/4/2014 1 of 1 Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Tuesday, August 05, 2014 2:21 PM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data Coordinator North Subject: lRoWlaring Summary August 1, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of one unplanned flaring event of greater than one hour which occurred at the Endicott Production Facility. This event was the result of a mechanical problem with the propane compressor. The compressor has since been repaired and brought back on-line. Summary of unplanned flaring events: 1 -August -14 08:36 (714 minutes, 303 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Ken Miller BPXA Environmental Advisor North Phone(907)659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Rich Vicente Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Wednesday, August 13, 2014 3:17 PM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data Coordinator North Subject: Endicott Flaring Summary August 6-11, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of several unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of a mechanical problem with the propane compressor. Repairs are currently in progress. Summary of unplanned flaring events: 6 -August -14 10:35 (139 Minutes, 123 MCF) 6 -August -14 13:06 (541 Minutes, 337 MCF) 6 -August -14 22:13 (107 Minutes, 10 MCF) 7 -August -14 00:00 (563 Minutes, 169 MCF) 8 -August -14 14:42 (558 Minutes, 198 MCF) 9 -August -14 00:27 (259 Minutes, 148 MCF) 9 -August -14 04:47 (559 Minutes, 184 MCF) 9 -August -14 14:08 (551 Minutes, 226 MCF) 10 -August -14 00:00 (248 Minutes, 138 MCF) 10 -August -14 04:56 (159 Minutes, 52 MCF) 10 -August -14 07:36 (984 Minutes, 316 MCF) 11 -August -14 00:00 (1,075 Minutes, 345 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Rich Vicente BPXA Environmental Advisor North Phone (907) 659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Ken Miller Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Wednesday, August 20, 2014 3:13 AM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data Coordinator North Subject: 11111011111iffiWaring Summary August 12-19, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of several unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of a mechanical problem with the propane compressor. Repairs are currently in progress. Summary of unplanned flaring events: 18 -August -14 15:00 (400 Minutes, 61 MCF) 18 -August -14 21:42 (138 Minutes, 32 MCF) 19 -August -14 00:00 (327 Minutes, 138 MCF) 19 -August -14 06:10 (778 Minutes, 81 MCF) 19 -August -14 20:51 (109 Minutes, 5 MCF) 19 -August -14 22:43 (77 Minutes, 2 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10422). Thank you, Rich Vicente BPXA Environmental Advisor North Phone(907)659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Ken Miller Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Monday, August 25, 2014 8:13 AM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data _Coordinator North Subject: Endicott Flaring Summary August 20-24, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of several unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of a mechanical problem with the propane compressor. Repairs to the propane compressor have been completed and it was successfully brought back on-line without excess emissions. Summary of unplanned flaring events: 20 -Aug -14 0:00 (113 minutes, 14 MCF) 20 -Aug -14 2:40 (165 minutes, 12 MCF) 20 -Aug -14 10:20 (664 minutes, 56 MCF) 21 -Aug -14 0:00 (124 minutes, 40 MCF) 22 -Aug -14 14:35 (250 minutes, 90 MCF) 22 -Aug -14 18:46 (314 minutes, 109 MCF) 23 -Aug -14 0:00 (74 minutes, 24 MCF) 23 -Aug -14 1:53 (860 minutes, 414 MCF) 23 -Aug -14 16:14 (103 minutes, 33 MCF) 23 -Aug -14 18:05 (216 minutes, 111 MCF) 23 -Aug -14 22:03 (117 minutes, 108 MCF) 24 -Aug -14 0:34 (78 minutes, 15 MCF) 24 -Aug -14 2:22 (198 minutes, 237 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Ken Miller AK, HSSEE Environmental Advisor North W (907) 659-6810 Harmony 6441 Alternate: Rich Vicente Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Wednesday, September 17, 2014 4:09 AM To: Roby, David S (DOA); Ferguson, Victoria L (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech, AK, HSSEE Env TL (North Slope), Fiedler, Anne M, Cooke, Alison D; AK, HSSEE Reg Env Data Coordinator North Subject: Endicott Flaring Summary August 25, 2014 through September 15, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of planned and unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of a production rate cut in response to a temporary TAPS slow down. Summary of unplanned flaring events: 29 -August -14 05:13 (1,127 Minutes, 388 MCF) Summary of planned flaring events: 30 -August -14 00:00 (1,440 Minutes, 899 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Rich Vicente BPXA Environmental Advisor North Phone(907)659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Ken Miller STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP 5. MonthNear of Disposition I Sep -2014 Disposition Volume MCF FO- production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 38,873 Pool Name Pool Code Percent 7. Reinjected 8,886,406 Endicott 220100 97.52% Sag Delta 220150 0.08% 8. Flared or vented t hour or less 11 Eider 220165 2.27% Minke Tract Cip 220170 0.12% 9. Flared or vented more than 1 hour (see instr.) 0 100.00% 10. Pilot and Purge 9,870 11. Assist Gas 22,350 12. Fuel gas used in lease operations. 964,992 13. Other (see instructions) Oficial Use Only Authorization 11 hr'. Safety MCFMCF 14. TOTAL VOLUME (ITEMS 6-13) 9,922,502 Lease Use 15. NGL Gas Equivalent 38,686 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Manager. Production Taxes and Royalties Note: All volumes must be Signature Title Alaska ��/ /// corrected to pressure of 14.65 psia JD /� /(y and to a temperature of 60o F. Printed Name Diane Coll e Phone (907)564-5775 Date / / Authoritv 20 AAC25.235. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Field Endicott 4. Operator I BP S. MonthNear of Disposition I Oct -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. sold 35,343 Pool Name Pool Code Percent 7. Reinjected 8,996,525 Endicott 220100 98.15% Sag Delta 220150 0.05% 8. Flared or vented 1 hour or less 793 Elder 220165 1.70% MinkeTractOp 220170 0.11% 9. Flared or vented more than t hour (see instr) 962 100.00% 10. Pilot and Purge 10,199 11. Assist Gas 23,000 12. Fuel gas used in lease operations. 943,522 13. Other (see instructions) Official Use OnlyMCF Authorization >i hr: 9G Z 14. TOTAL VOLUME (ITEMS 6-13) 10,010,344MCF rS.fety, seUse15. NGL Gas Equivalent 35,121 seation MCF 16. Purchased gas Waste: MCF 17. Transferred from i -2—/� /-2-/S- L�� Com issioner Date 18. 18. Transferred to: (Express as a negative #)F 19. Remarks: Block 6 includes gas sold to Badami, gas sold to Liberty and the NGL gas equivalent sold. Gas sold to the Endicott Pipeline Company is included in Block 12. 1 hereby certify that the foregoing is true and correct to the best of my knowledge. 00 A Manager, Production Taxes and Royalties Note: All volumes must be Signature /�'�/ rifle Alaska corrected to pressure of 14.655 psia 6ft and to a temperature of 60o F. Printed Name Diane Colley Phone (907)584-5775 Data I1//q Authority 20 AAC25.235. rz/fq/)4 V —L ,1111= TOTAL 793 BP EXPLORATION (ALASKA) INC. ADMINISTRATIVE APPROVAL NO. 202.4 GAS FLARING INCIDENT REPORT - ENDICOTT Oct -2014 Not required for unplanned events which Not required for unplanned events which are less than or equal to 1 hour are less than or equal to 1 hour 10/5/2014 1324-1654 261 B booster down Restarted B booster 10/15/2014 1148-1315 36 Cleaning flare Shut lift gas to flare TOTAL 297 Planned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF tt+ gp.ENT 4CAUSE ACTION TAKEN TO EUMMA.TE CAUSE 1.nts TOTAL 0 Not required for planned events which Not required for planned evI 11e1.which are less than or equal to 1 hour are less than or equal to 1 hour Planned Events greater than 1 hour DATE : TIME VOLUME ;: : OESC;.. PTION 4�1NCtp6Nk�'�,. ,.�I � ACTION iAk�N:'fA �1.8VIINATE CAUSE 10/13-14/2014 1503-2052 665 Water washed A -Main Turbine Wash completed TOTAL 665 tOTAL Eli[3R t4K� SGN1f�gJ;OTT: Volume flared less than 1 hr 793 13 1 0 779 Volume flared greater than 962 16 1 0 945 1 hr Pilot Purge 10,199 173 11 5 10,010 Assist Gas 23.000 390 25 11 22574 TOTAL FLARED VOLUME 34,954 592 38 16 34,308 11/6/2014 1 of 1 Hunt, Jennifer L (DOA) From: AK, HSSEE Env Adv North [AKHSSEEEnvAdvNorth@bp.com] Sent: Monday, October 27, 2014 12:20 PM To: Roby, David S (DOA); Loepp, Victoria T (DOA); Hunt, Jennifer L (DOA) Cc: AK, OPS END Facility & FieldO&M TL; AK, OPS END Operations Lead Tech; AK, HSSEE Env TL (North Slope); Fiedler, Anne M; Cooke, Alison D; AK, HSSEE Reg Env Data oordinator North Subject: INMIMIaring Summary October 13 - 15, 2014 To: Dave Roby, AOGCC Victoria Ferguson, AOGCC Jennifer Hunt, AOGCC BPXA is providing courtesy notification of planned and unplanned flaring events of greater than one hour which occurred at the Endicott Production Facility. These events were the result of a shutdown of the A Main compressor for water washing Summary of unplanned flaring events: 15 -October 2014 07:10(164 Minutes, 93 MCF) Summary of planned flaring events: 13 -October 2014 19:39 (556 Minutes, 505 MCF) 14 -October 2014 16:47 (96 Minutes, 89 MCF) All attempts were made to identify problems, expedite maintenance, and keep flaring & assist gas to a minimum. Given these circumstances, we believe that we took all necessary actions in accordance with good oil field engineering practices and conservation purposes to minimize the volume of gas released, burned, or permitted to escape to the air. These volumes will also be reported to you on the Facility Report of Produced Gas Disposition Form (Form 10-422). Thank you, Ken Miller BPXA Environmental Advisor North Phone(907)659-6810 Pager 659-5272, #4313 Harmony (907) 659-6441 Alternate: Rich Vicente Name STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION a 6. Sold 1,713 7. Reinjected 9,750,343 8. Flared or vented 1 hour or less 64 9. Flared or vented more than 1 hour (see instr.) 474 10. Pilot and Purge 14,520 11. Assist Gas 17,334 12. Fuel gas used In lease operations 973,685 13. Other (see instructions) 0 14. TOTAL VOLUME (ITEMS 6.13) 10,758,133 15. NGL Gas Equivalent 0 16. Purchased gas - Rental Return Gas 0 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 that Line 6Includes gas sold to Savant for fuel usage at Badami Unit. my as a to pressure of 14.65 psia and to a temperature of 80o F. Authority 20 he Safety 4-TA'T MCF Lease Use MCF Conservation MCF MCF C missioner Date to pressure of 14.65 psia and to a temperature of 80o F. Authority 20 OR FLARING EVENTS GREATER THAN 1 HOUR Excess flaring necessary until 71/01/2074 724250 0290000002 11/2/2014 9:32:OOAM 2:35:00 PM 11/2/2014 N 386.0 Excess flaring due to unscheduled compressor could be loaded shutdown of boodosterer comcompressor. and restarted. Excess flaring due to well spikes Excess flaring necessary until 11/01/2014 124250 0290000002 11/4/2014 2:01:00 AM 3:08:00 AM 11/4/2014 N 90.0 caused by kicking from wells that well could be brought back to were brought back on line. normal operation. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION 1. Facility Number 0290000002 2. Facility Name DIU Endicott 3. Held Endicott v. upe�aw� HILCORP ALASKA LLC �.,u,� __ ��.,r....^•... December 2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 276 Pool Name Pool Code Percent 7. Reinjected 10,383,694 ENDICOTT,ENDICOTTOIL 220100 97.98% ENDICOTT. IVISHAK OIL 220150 0.05% S. Flared or vented 1 hour or less 88 ENDIC077. EIDER OIL 1 220165 1.89% ENDICOTT, SAGIIVISHAK OIL 220170 0.09% 9. Flared or vented more than 1 hour (see instr.) 0 10. Pilot and Purge 15,004 11. Assist Gas 17,823 12. Fuel gas used in lease operations 1,046,144 13. Other (see instructions) 0 Official Use Only Authorization >1 hr. Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 11,463,029 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Rental Return Gas 0 Waste: JMCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 1B. Transferred to: 0 19. Remarks: Line 6 includes gas sold to Savant for fuel usage at Badami Unit. :ertify that the foregoing is true and correct to the best of my Knowledge. Note: All volumes must be corrected Signature �� Title Production Supervisor pressure of 14.65 psia and to a temperature of 600 F. Authority 20