Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutPBU GC 2 Gas DispositionState of Alaska AOGCC Gas Disposition Files Year: 2014 Facility: PBU GC 2 Operator: BP EXPLORATION (ALASKA) STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition January -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. ReinjectedO PRUDHOE 640150 94.31% AURORA 640120 1.20% 8. Flared or vented 1 hour or less 328 BOREALIS 640130 3.62% ORION 640135 0.44% 9. Flared or vented more than 1 hour (see instr.) 0 POLARIS 640160 0.43% 10. Pilot and Purge 28,554 11, Assist Gas 0 12. Fuel gas used in lease operations. 656,974 13. Other (see instructions) U Official Use Only Authorization >t hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 685,856 Lease Use MCF 15, NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste MCF 17. Transferred from: 0 16. Transferred to: (Express as a negative #) CGF -21,157,491 Commissioner Date 19. Remarks. I hereby certify that the foregoing is true and correct to the best of my knowledge. lrnM f Note: All volumes must be corrected Signature AG(C,4rf U Title Manager Production Taxes and Rovalties Alaska to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date 41M AAC25.235. Form 10-422 Rev. 512009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. FacilityNumber2. 0290000032 Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition February -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 92.83% AURORA 640120 2.10% 8. Flared or vented 1 hour or less 9 722 BOREALIS 640130 3.78°/ ORION 640135 0,55% 9. Flared or vented more than 1 hour (see instr) 436,111 POLARIS 640160 0.74 % 10. Pilot and Purge 24,976 11. Assist Gas 0 12. Fuel gas used in lease operations. 351,502 13. Other (see instructions) 0 Official Use Only Authorization >t hr : Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 822,311 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 Cornmissioner Date/ -i 18. Transferred to: (Express as a negative #) CGF -14,169,427 19. Remarks: I hereby certify that the foregoing istrue and correct to the best of my knowledge. r / r M//n I/1 Note: All volumes must be corrected Signature (--t. A./i/JtX l Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date J10liq AAC25.235. 1/t- I-- 6.1,7114 G/,7/14 Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -2 GAS FLARING INCIDENT REPORT February 2014 Page 8 DATE TIME VOLUME DESCRIPTION OF INCIDENT& CAUSE - ACTION TAKEN TO ELIMINATE CAUSE 2/15/2014 0425-0505 9,722 Not required for unplanned events <=1 hr Not required for unplanned events <=1 hr 2/16-19/2014 TOTAL 9,722 DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 2/15/2014 0505-2305 34,236 See Attachments See Attachments 2/16-19/2014 0300-0810 401,875 TOTAL 436,111 Planned Events Less Than or Equal 1 Hour AND <= 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned Events Exceeding 1 Hour OR > 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 9,722 Unplanned Events > 1 Hour 436,111 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 24,976 Assist 0 TOTAL FLARED VOLUME 470,809 3/12/2014 4:56 PM Flare Start Date 02/01/2014 Flare End Date 02/28/2014 GC2 Flare Report Total Volume (MSCF) 445833 Report Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 14-48 Flare Relief 02/15/2014 5:05:00 am 1:30:00 pm 505 min No No No Determination Cause LPS compressor K-7000 shut down because of a problem associated with Hi speed trip Action Taken Reduced rates and shut in and freeze protected Ip wells 14-48 Flare Relief 02/15/2014 1:30:00 pm 11:05:00 pm 575 min No No No Determination Cause LPS compressor K-7000 shut down because of a problem associated with Hi speed trip Action Taken Reduced rates and shut in and freeze protected 1p wells 14-49 Flare Relief 02/16/2014 3:00:00 am 12:00:00 am 1260 min No No No Determination Cause LPS compressor K-7000 shut down because of a problem associated with Hio speed trip Action Taken Reduced rates and freeze protected wells, maintained minimum flows to keep facility from freezing 14-52 Flare Relief 02/17/2014 12:00:00 am 12:00:00 am 1440 min No No No Determination Cause LPS compressor K-7000 shut down because of a problem associated with Hi Speed ncozle clevis Action Taken Reduced rates to minimum required for facility freeze protect, shut in wells and FP 14-55 Flare Relief 02/18/2014 12:00:00 am 120000 am 1440 min No No No Determination Cause LPS compressor K-7000 shut down because of a problem associated with hi -speed nozzle clevis Action Taken Shut in and F/P wells and reduced rates to minimum for facility freeze protection 14-56 Flare Relief 02/19/2014 12:00:00 am 8:10:00 am 490 min No No Yes Determination Cause LPS compressor K-7000 and K-7001 shut down due to a problem associated with Waste Heat. Action Taken Started K-7001 BP1\SQUIP2 12274 BPI\SQUIP2 21962 BP7\SQUIP2 109375 BP1\SQUIP2 125000 BP1\SQUIP2 125000 BP1\LOTTCE 42500 Total Volume (MSCF) 445833 Generated 03/04/2014 2:15:08PM Page 8 of 9 Hunt, Jennifer L (DOA) From: AK, OPS PCC EOC TL [AKOPSPCCEOCTL@bp.comj Sent: Tuesday, February 18, 2014 9:47 AM To: Hunt, Jennifer L (DOA) Cc: Ferguson, Victoria L (DOA); Roby, David S (DOA); Castano, Alejandra; Benson, Gary A; Arthur, Gregory; Kruger, Dale O; AK, OPS GC2 OSM; AK, OPS GC2 Facility OTL; AK, OPS PCC EOC TL; AKHSSEEEnvAdvWest@bp.com Subject: Gas flaring events at GC2 To: Jennifer Hunt, AOGCC Jennifer hunt(c alaska.gov CC: Dave Roby, AOGCC dave roby(cbalaska.00v From: Kellie Okonek, GPB Production Optimization Team Leader CC: Victoria Ferguson, AOGCC victoria ferouson@alaska.gov A flaring event occurred at GC2 starting at 02/15/2014 13:30 and stopping at 02/15/2014 23:05 with a volume of 21962 (MSCF). The event lasted for 575 minutes. The event had a volume greater than 5000 (MSCF). A Flaring event occurred at GC2 starting at 02/15/2014 05:05 and stopping at 02/15/2014 13:30 with a volume of 12274 (MSCF). The event lasted for 505 minutes. The event had a volume greater than 5000 (MSCF). A flaring event occurred at GC2 starting at 02/15/2014 04:25 and stopping at 02/15/2014 05:05 with a volume of 9722 (MSCF). The event had a volume greater than 5000 (MSCF). A flaring event occurred at GC2 starting at 02/17/2014 00:00 and stopping at 02/18/2014 with a volume of 125000 (MSCF). The event lasted for 1440 minutes. The event had a volume greater than 5000 (MSCF). A flaring event occurred at GC2 starting at 02/16/2014 03:00 and stopping at 02/17/2014 with a volume of 109375 (MSCF). The event lasted for 1260 minutes. The event had a volume greater than 5000 (MSCF). These events were due to LPS K7000 compressor shutdown due to high speed trip. K7001 was already down for planned maintenance, so rates were reduced to minimum rates necessary to keep piping warm until freeze protect could be complete. Please let me know if you have any questions. Kellie Okonek (alt. Travis Rybicki) PCC/EOC Production Optimization TL external: (907) 659 4472 (BOC) / 5566 (PBOC) cell: (907) 382 1370 Harmony: 758 4404 Pager 574 (WOA - access # 4236) or 1890 (EOA - access #5100) e-mail akopspcceoctl(a)bp com Hunt, Jennifer L (DOA) From: AK, OPS PCC EOC TL [AKOPSPCCEOCTL@bp.com] Sent: Tuesday, March 04, 2014 1:41 PM To: Hunt, Jennifer L (DOA) Cc: Ferguson, Victoria L (DOA); Roby, David S (DOA); Castano, Alejandra; Benson, Gary A; Arthur, Gregory; Kruger, Dale O; AK, OPS GC2 OSM; AK, OPS GC2 Facility OTL; AK, HSSEE Env Adv West Subject: Gas flaring events at GC2 To: Jennifer Hunt, AOGCC jennifer hunt@alaska oov CC: Dave Roby, AOGCC dave roby(a)alaska.gov From: Travis Rybicki, GPB Production Optimization Team Leader CC: Victoria Ferguson, AOGCC victoria.ferguson@alaska.gov A flaring event occurred at GC2 starting at 02/18/2014 00:00 and stopping at 02/19/2014 with a volume of 125000 (MSCF). The event lasted for 1440 minutes. The event continued into the following day. A flaring event occurred at GC2 starting at 02/19/2014 00:00 and stopping at 02/19/2014 08:10 with a volume of 42500 (MSCF). The event lasted for 490 minutes. Flaring continued until offline LPS T/C K7001 was started after completion of planned overhaul maintenance work. Flaring ended when the unit was started, loaded and the flare valves closed. These events were due to LPS K7000 compressor shutdown due to high speed trip. K70ol was already down for planned maintenance, so rates were reduced to minimum rates necessary to keep piping warm until freeze protect could be complete. Please let me know if you have any questions. Travis M. Rybicki PCC-EOC (Production optimization) ream Lead Office 907-659-4472 (BOC) 659-5566 (PBOC) Cell 907-227-8133 Harmony 758-4404 GPB Pager 907-659-5272 # 1890 akopspcceoctl(obp. Com Alternate: Kellie Okonek STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name PBU l 2 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition March -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 91.00% AURORA 640120 2.35% 8. Flared or vented l hour or less 0 BOREALIS 640130 5.43% ORION 640135 0.51% 9. Flared or vented more than 1 hour (see instr.) 0 POLARIS 640160 0.71% 10. Pilot and Purge 25,390 11. Assist Gas 0 12. Fuel gas used in lease operations. 552,394 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 577,784 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 Commissioner Date 18. Transferred to: (Express as a negative #) CGF -18,762,157 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. y�i]]�� �///�1�1��,//t��%gg/ Signature 81b eaw Title Marm er Production Taxes and Royalties Alaska Note: Alf volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. // // Printed Name Diane ColleyPhone (907) 564-5775 Date N Form 10-422 Rev. 512009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number2. 0290000032 Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator JBP 5. MonthNear of Disposition I April -2014 Disposition Volume MCF 20. Forproduchon from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Q Pool Name Pool Code Percent 7. Reinjected Q PRUDHOE 640150 91.92% AURORA 640120 1.98% 8. Flared or vented hour or less 1,267 BOREALIS 640130 4.67°/ ORION 640135 0.48% 9. Flared or vented more than 1 hour (see instr.) 8,609 POLARIS 640160 0.95% 10. Pilot and Purge 24,945 11. Assist Gas Q 12. Fuel gas used in lease operations. 570,222 13. Other (see instructions) 0 Official Use Only Authorization >1 hr. Safety !O 14. TOTAL VOLUME (ITEMS 6-12) 605,063 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Q Waste: MCF 17. Transferred from: Q / _A U-thV 18. Transferred to: (Express as a negative #) CGF -17,814,126 Commissioner Date 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. �j�� //j/!/I,/(y/,Jl� Signature e/ Y �"'" V Title Manager Production Taxes and Royalties Alaska Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. /_ Printed Name Diane ColleyPhone (907) 564-5775 Date �/ `� Vt- Form 10-422 Rev. 512009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRU DHOE BAY UNIT - GC -2 GAS FLARING INCIDENT REPORT April 2014 Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 4/1/2014 2335-2337 69 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 4/10/2014 2035-2055 278 4/14/2014 0430-0443 135 4/20/2014 0750-0811 292 4/28/2014 1535-1606 332 TOTAL 1,106 4/21/2014 0055-0415 1,262 See Attachments See Attachments 4/25/2014 0950-1052 431 4/30/2014 1055-1905 6,465 TOTAL 8,158 4/27/2014 1637-1651 97 See Attachments See Attachments 4/29/2014 1121-1132 84 TOTAL 181 Page 7 4/27/2014 1432-1537 451 See Attachments See Attachments TOTAL 451 TOTAL Unplanned Events < 1 Hour 1,106 Unplanned Events > 1 Hour 8,158 Planned Events < 1 hour and not 181 exceeding 5,000 NICE Planned Events> 1 hour or 451 V exceeding 5,000 MCF Pilot Purge 24,945 Assist 0 TOTAL FLARED VOLUME 34,841 5/15/2014 10:51 AM Flare Start Date 04/01/2014 Flare End Date 04/30/2014 GC2 Flare Report Total Volume (MSCF) 9896 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 14-132 Flare Relief 04/21/2014 12:55:00 am 4:15:00 am 200 min No No Determination Cause LPS compressor K-7000 shut down because of water wash Action Taken WOA reduced production rates and shut-in wells for water wash of LPS compresser 14-134 Flare Relief 04/25/2014 9:50:00 am 10:52:00 am 62 min No No Determination Cause LPS Compressor K-7000 sprang water wash. Action Taken Water Wash complete. 14-137 Flare Relief 04/27/2014 2:32:00 pm 3:37:00 pm 65 min No No Determination Cause LPS Compressor K-7001 water wash. Action Taken Water wash complete. No 131`1\LEGNJB 1262 No BP11STYVJW 431 Yes BP1\PAOLINJM 451 14-137 Flare Relief 04/27/2014 4:37:00 pm 4:51:00 pm 14 min No No Yes BPI\PAOLINJM 97 Determination Cause Start up K-7001 after spring water wash. Action Taken K-7001 started. 14-139 Flare Relief 04/29/2014 11:21:00 am 11:32:00 am 11 min No No Yes BPI\PAOLINJM 84 Determination Cause Startup of LPS Compressor K-7001, Copus discharge gas to flare. Action Taken LPS Compressor up and and in service. 14-140 Flare Relief 04/30/2014 10:55:00 am 7:05:00 pm 490 min No Yes No BP1\SQUIP2 ` 465 Generated 05/05/2014 10:32:25AM Page 7 of 9 Flare Start Date 04/01/2014 Flare End Date 04130/2014 Determination Cause LP 8 IP compressor problems due to low rate while dealing with H Pad shut in. Action Taken Flaring was permitted to continue while GC operations personnel cycled safety trip reset on LP compressor. Total Volume (MSCF) 9896 Generated 05/05/2014 10:32:25AM Page 8 Of 9 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name IP GC 2 3. Field PBU - WOA 4. Operator BP 5. MomhNear of Disposition Ma -2014 Disposition Volume MCF 20. Forproduction from multiplepools, list contribution ofeach poolas apercentof Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 91.58% AURORA 640120 2.203/o 8. Flared or vented 1 hour or less 0 BOREALIS 640130 4.57% ORION 640135 0.71% 9. Flared or vented more than 1 hour (see instr.) 11,191 POLARIS 640160 0.94% 10. Pilot and Purge 34,521 11. Assist Gas 0 12. Fuel gas used in lease operations. 481,537 13. Other (see instructions) 0 Official Use Only Authorization >I hr. Safety � l / q / MCF 14. TOTAL VOLUME (ITEMS 6-12) 527,249 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: 0 1 —2-4_ Commissioner Date 18. Transferred to: (Express as a negative #) CGF -13,825,162 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature LM L�U.!l�iV V Title Manager Production Taxes and Royalties Alaska Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. )r Printed Name Diane ColleyPhone (907) 564-5775 Date / r -/-z t- / 14 Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT -GC -2 GAS FLARING INCIDENT REPORT May 2014 DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE Not required for unplanned events <= 1 hr TOTAL 0 DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE 5/13/2014 0823-1115 4,777 See Attachments 5/23/2014 1001-1444 6,289 5/25/2014 0115-0245 125 TOTAL TOTAL 11,191 Planned Events Less Than or Eoual 1 Hour AND <= 5.000 mcf Not required for unplanned events <= 1 hr ACTION TAKEN TO ELIMINATE See Attachments Page 8 TOTAL See Attachments 0 See Attachments Planned Events Exceeding 1 Hour OR > 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events> 1 Hour 11,191 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 34,521 Assist 0 TOTAL FLARED VOLUME 45,712 6/12/2014 10:40 AM Flare Start Date 05/01/2014 Flare End Date 05/31/2014 GC2 Flare Report Total Volume (MSCF) 11191 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 14-162 Flare Relief 05/13/2014 8:23:00 am 11:15:00 am 172 min Yes No No BPl\WALGAB 4777 Determination Cause IP compressor shut down because of a problem associated with quad log fault Action Taken Equipment was restarted at 1115 hours. 14-171 Flare Relief 05/23/2014 10:01:00 am 2:44:00 pm 283 min Yes Yes No BP1\STYVJW 6289 Determination Cause STOP PRODUCTION oocured during a PLC work on PWX, cause under investigation. Action Taken PLC work complete, facility retunred to production. 14-175 Flare Relief 05/25/2014 1:15:00 am 2:45:00 am 90 min No No No BP1\PAOLINJM 125 Determination Cause Depressured Q-01, 02 and 03 to flare via test bank for maintenance on the well pad. Action Taken Amlines depressured and flare valve closed. Total Volume (MSCF) 11191 Generated 06/03/2014 9:13:32AM Page 9 of 10 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition June -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold O Pool Name Pool Code Percent 7. Reinjected O PRUDHOE 640150 93.78% AURORA 640120 2.14% 8. Flared or vented 1 hour or less 3,162 BOREALIS 640130 2.95% ORION 640135 0.40% 9. Flared or vented more than 1 hour (see instr.) 606 POLARIS 640160 0.733/6 10. Pilot and Purge 30,128 11. Assist Gas 0 12. Fuel gas used in lease operations. 620,456 13. Other (see instructions) U Use Only Authorization tion >7 hr: Safety � U MCF 14. TOTAL VOLUME (ITEMS 6-12) 654,352 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: U -3 Commissioner Date 18. Transferred to: (Express as a negative #) CGF -18,970,470 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Mr'1�� Note: All volumes must be corrected Signature N tl (..(,� Title Mana er Production Taxes and Ro alties Alaska to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date 7 /I/ L I AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT- GC -2 GAS FLARING INCIDENT REPORT Page 7 June 2014 DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE LAUSE 6/23/2014 1157-1219 183 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 6/24/2014 0754-0758 14 Planned Events > 1 hour or 0 6/29/2014 0904-0911 340 Pilot Purge 30,128 6/29/2014 1031-1113 2,625 TOTAL FLARED VOLUME 33,896 TOTAL 3,162 Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 6/23/2014 0727-0916 606 See Attachments See Attachments TOTAL 606 Planned Events Less Than or Equal 1 Hour AND <= 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 Planned Events Exceeding 1 Hour OR > 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 7/16/2014 1:45 PM TOTAL Unplanned Events < 1 Hour 3,162 Unplanned Events> 1 Hour 606 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 30,128 Assist 0 TOTAL FLARED VOLUME 33,896 7/16/2014 1:45 PM Flare Start Date 06/01/2014 Flare End Date 06/30/2014 M Flare Report Total Volume (MSCF) 3766 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 14-210 Flare Relief 06/23/2014 7:27:00 am 9:16:00 am 109 min Yes No No BPi1STYVJW 606 Determination Cause High gas transit line pressure caused by a increase in ambient temps 8 GLT compressor (Big AL) shutting down. Action Taken Production rate were lowered and GLT machine was (BIG AL) brought back online. Total Volume (MSCF) 3768 Generated 07/09/2014 3:12:32PM Page 7 of 7 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. Month/Year of Disposition July -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 94.55% AURORA 640120 1.04% 8. Flared or vented ihour or less 1,711 BOREALIS 640130 3.68% ORION 640135 0.51% 9. Flared or vented more than 1 hour (see instr.) 7812 POLARIS 640160 0.22% 10. Pilotand Purge 17,941 11, Assist Gas 0 12. Fuel gas used in lease operations. 339,453 13. Other (see instructions) 0 Official Use Only Authorization >7 hr: Safety ! Z MCF 74. TOTAL VOLUME (ITEMS 6-12) 366,917 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 ! Commissioner Date 18. Transferred to: (Express as a negative #) CGF -10,818,717 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature u// GL Title Manager Production Taxes and Royalties Alaska to pressure of 14.65 psia and to a / , temperature of 60o F. Authority 20 Printed Name Diane ColleyPhone (907) 564-5775 Date �I AAC25.235. VI,r Form 1OA22 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT -GC -2 GAS FLARING INCIDENT REPORT July 2014 Unplanned Events less than or equal to 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/10/2014 2240-2255 20 Not required for unplanned events <=1 hr Not required for unplanned events <= 1 hr 7/17/2014 0122-0219 1,583 TOTAL 1,603 Page 8 DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/12/2014 2115-2230 7,812 See Attachments See Attachments TOTAL 7,812 Planned Events Less Than or Equal 1 Hour AND <= 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 7/17/2014 2306-2332 108 See Attachments See Attachments TOTAL 108 DATE TOTAL Unplanned Events < 1 Hour Unplanned Events > 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 0 TOTAL 1,603 7,812 108 0 17,941 0 27,464 DESCRIPTION OF INCIDENT & CAUSE See Attachments See Attachments 8/14/2014 2:23 PM Flare Start Date 07/01/2014 Flare End Date 07/31/2014 GC2 Flare Report Total Volume (MSCF) 9523 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 14-243 Flare Relief 07/12/2014 9:15:00 pm 10:30:00 pm 75 min No Determination Cause High ambient temps Action Taken EOA reduced production No No BPI\WALLC7 7812 14-248 Flare Relief 07/17/2014 11:06:00 pm 11:32:00 pm 26 min Yes No Yes BP1\PAOLINJM 108 Determination Cause Plant coming down for TAR, low gas rates caused LP and IP compressors to loose forward bow, flared off LP knockout. Action Taken Shut compressors down, no flow into plant Flare valves closed. Total Volume (MSCF) 9523 Generated 08/04/2014 11:24:17AM Page 10 of 11 Hunt, Jennifer L (DOA From: AK, OPS PCC EOC TL [AKOPSPCCEOCTL@bp.comj Sent: Sunday, July 20, 2014 12:30 PM To: Hunt, Jennifer L (DOA) Cc: Ferguson, Victoria L (DOA); Roby, David S (DOA); Castano, Alejandra; Benson, Gary A; Arthur, Gregory; AK, HSSEE Env Adv West; Kruger, Dale O; AK, OPS GC1 Facility OTL; AK, OPS GC1 OSM; AK, OPS GC2 OSM; AK, OPS GC2 Facility OTL; AK, OPS GC3 Facility & Field OTL; AK, OPS GC3&PCC OSM Subject: Gas flaring events at GC1,090 GC3 To: Jennifer Hunt, AOGCC CC: Dave Roby, AOGCC CC: Victoria Ferguson, AOGCC iennifer hunt(6alaska.gov dave.robv(a)alaska.aov victoria ferousone-alaska.aov From: Kellie Okonek, GPB Production Optimization Team Leader GC1 A flaring event occurred at GCI starting at 06/17/2014 03:00 and stopping at 06/18/2014 with a volume of 1090 (MSCF). The event lasted for 1260 minutes, and was due to LP compressor instability due to temperature swings. Flaring stopped when necessary process changes were made. A flaring event occurred at GC1 starting at 06/20/2014 05:08 and stopping at 06/21/2014 with a volume of 2616 (MSCF). The event lasted for 1132 minutes, and was due to low oil throughput causing insufficient LP/IP gas. A flaring event occurred at GC1 starting at 06/21/2014 00:00 and stopping at 06/21/2014 05:25 with a volume of 2408 (MSCF). The event lasted for 325 minutes, and was due to low oil throughput causing insufficient LP/IP gas. A flaring event occurred at GC1 starting at 06/23/2014 14:10 and stopping at 06/23/2014 15:45 with a volume of 1200 (MSCF). The event lasted for 95 minutes, and was due to a blown UPS fuse causing an LPS compressor shutdown. Flaring stopped when the compressor was re -loaded. A flaring event occurred at GC1 starting at 06/25/2014 08:45 and stopping at 06/25/2014 10:00 with a volume of 1437 (MSCF). The event lasted for 75 minutes, and was due to an unplanned shutdown of A/B banks to the GCI annex. Flaring stopped when the banks were put back in service. A flaring event occurred at GC1 starting at 07/02/2014 00:01 and stopping at 07/03/2014 with a volume of 3400 (MSCF). The event lasted for 1439 minutes, and was due to a UPS power failure to the skid 7 control room. Flaring stopped when UPS was fixed and power restored. A flaring event occurred at GC1 starting at 07/03/2014 00:01 and stopping at 07/03/2014 06:30 with a volume of 1600 (MSCF). The event lasted for 389 minutes, and was due to a UPS power failure to the skid 7 control room. Flaring stopped when UPS was fixed and power restored. A flaring event occurred at GC1 starting at 07/04/2014 06:00 and stopping at 07/04/2014 12:00 with a volume of 280 (MSCF). The event lasted for 360 minutes, and was due to 2 stage D -bank backpressure controller issues. Flaring stopped when the backpressure controller was re -adjusted. A flaring event occurred at GC1 starting at 07/08/2014 04:00 and stopping at 07/08/2014 22:30 with a volume of 940 (MSCF). The event lasted for 1110 minutes, and was due to loss of forward flow on IP compressors. Flaring stopped when temperature/pressure adjustments made to re-establish flow. A flaring event occurred at GC1 starting at 07/17/2014 18:00 and stopping at 07/18/2014 with a volume of 8170 (MSCF). The event lasted for 360 minutes. The event had a volume greater than 5000 (MSCF), and was due to depressurization of Y/P pads for safe -out. Flaring stopped when depressurization was complete. A flaring event occurred at GC1 starting at 07/18/2014 04:00 and stopping at 07/19/2014 with a volume of 6886 (MSCF). The event lasted for 1200 minutes. The event had a volume greater than 5000 (MSCF), and was due to shutdown and depressure of GHX tie -line between GC1 &2 for GC2 planned turnaround. GC2 A flaring event occurred at GC2 starting at 06/23/2014 07:27 and stopping at 06/23/2014 09:16 with a volume of 606 (MSCF). The event lasted for 109 minutes, and was due to high gas transit pressure caused by an increase in ambient temperatures and EOA 1806 compressor shutdown. A flaring event occurred at GC2 starting at 07/12/2014 21:15 and stopping at 07/12/2014 22:30 with a volume of 7812 (MSCF). The event lasted for 75 minutes. The event had a volume greater than 5000 (MSCF), and was due to high ambient temperatures causing transit gas system issues. Flaring stopped when rates were cut on the EOA. GC3 A flaring event occurred at GC3 starting at 07/19/2014 14:48 and stopping at 07/19/2014 17:35 with a volume of 1160 (MSCF). The event lasted for 167 minutes, and was due to wet gas compressor shutdown due to control/instrumentation failure associated with a fault. Production was reduced to minimize flaring. Please let me know if you have any questions. Kellie Okonek (alt. Travis Rybicki) PCCIEOC Production Optimization TL external: (907) 659 4472 (BOC) / 5566 (PBOC) cell: (907) 382 1370 Harmony: 758 4404 Pager 574 (WOA - access # 4236) or 1890 (EOA - access #5100) e-mail akoosocceoctl U)bo com STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION Peen 1Tv REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 0290000032 PBU GC 2 Disposition 3. Field PBU - WOA Volume MCF 4. Operator 5. MonthNear of Disposition BP August -2014 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 100.00% AURORA 640120 0.00% 8. Flared or vented 1 hour or less 0 BOREALIS 640130 0.00% ORION 640135 0.00% 9. Flared or vented more than 1 hour (see instr.) 0 POLARIS 640160 0.00% 10. Pilot and Purge 10,276 11. Assist Gas 0 12. Fuel gas used in lease operations. 15,933 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 26,209 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 Commissioner Date 18. Transferred to: (Express as a negative #) CGF -147,250 19. Remarks: I hereby certify that a foregoing is t e an mact to the best of my knowledge. Signature Title Manager Production Taxes and Ro alties Alaska Printed Name Diane Colley Phone (907) 564-5775 Date %11q Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition September -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Cade Percent 7. Reinjected U PRUDHOE 640150 93.35% AURORA 640120 1.08% 8. Flared or vented 1 hour or less 153 BOREALIS 640130 4.87% ORION 640135 0.35% 9. Flared or vented more than 1 hour (see instr.) 51,319 POLARIS 640160 0.35°/ 10. Pilot and Purge 30,276 11. Assist Gas 0 12. Fuel gas used in lease operations. 541,218 13. Other (see instructions) 0 Official Use Only Authorization >t hr: Safety ✓ MCF 14. TOTAL VOLUME (ITEMS 6.12) 622,966 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 3-2-3—/S- -Z3/S'18. Commissioner Date 18, Transferred to: (Express as a negative #) CGF -14,996,275 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. n ( Signature `� "]�,i' Title Manager Production Taxes and Ro allies Alaska Note: All volumes must corrected to pressure of 14.65 psisis and to a temperature of 60o F. Authority 20 AAC25.235. �� Printed Name Diane Co Phone (907) 564-5775 Date t— (� Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -2 GAS FLARING INCIDENT REPORT September 2014 Unplanned Events less than or equal to 1 hour DATE TIME E R4LTI£fN.TM1KENTi?#GINEINEkTEAi1S£ 9/13/2014 1658-1714 111 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 9/26/2014 1018-1028 42 TOTAL 153 Page 1 uA1F ;:ttma.: VULUNI[ }1C>4i{rrS lvry Vr +anFn 9/1/2014 0600-2349 11,878 See Attachments See Attachments 9/2/2014 0001-2359 11,983 9/3/2014 1400-2230 2,833 9/16/2014 1345-1500 260 9/27/2014 1000-2045 18,365 TOTAL 45,319 Planned Events Less Than or Equal 1 Hour AND <= 5,000 mcf DATE TIME VOLUME Oe54AMIitN O:)'1AICL(]�N1'<Si A15F ACTION TAkEif 9/7/2014 See Attachments See Attachments TOTAL 0 Planned Events Exceeding 1 Hour OR > S,000 mcf DATE T3ME V1.OLUME DESCRIPTION OF MCHJENT;& A.USE ? ACfiQNTAMEN T4ELIM(INATE W.,.. .. ., ,:. 0730-2330 6,000 See Attachments See Attachments TOTAL 6,000 Unplanned Events < 1 Hour Unplanned Events> 1 Hour Planned Events < 1 hour and not exceeding 5,000 MCF Planned Events > 1 hour or exceeding 5,000 MCF Pilot Purge Assist TOTAL FLARED VOLUME 153 45,319 0 6,000 30,276 a 81,748 10/16/2014 10:35 AM Flare StartDate 09/01/2014 Flare End Date 09/30/2014 14-380 Flare Relief 09/16/2014 1:45:00 pm 3:00:00 pm 75 min No Determination Cause Tandem Compressor down for mail. Gas header up to 630# Action Taken EOA & WOA cut rates _ No No 14-392 Flare Relief 09/27/2014 10:00:00 am 8:45:00 pm 645 min Yes No Determination Cause IP and LP compressor shut down due to hydration of gas plant outlet pipe Action Taken Equipment was restarted BPI\WALLC7 260 No BP1\WALGAB 18365 Total Volume (MSCF) 51472 Page 10 of 10 Generated 10/02/2014 2:36:16PM GC2 Flare Report Total Volume (MSCF) 51472 Report Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume Numbe System 14-340 Flare Relief 09/01/2014 6:00:00 am 11:49:00 pm 1069 min Yes Yes No BP1\STYVJW 11878 Determination Cause IP compressor shut down because of a problem associated with start up. Action Taken On going problems associated with start up. 14-345 Flare Relief 09/02/2014 12:01:00 am 11:59:00 pm 1438 min Yes Yes No BP1\STYVJW 11983 Determination Cause IP compressor shut down because of a problem associated with startup. Action Taken On going problems associated with start up.— _ — __---- 14-348 Flare Relief 09/03/2014 2:00:00 pm 10:30:00 pm 510 min No No No SP1\WALLC7 2833 Determination Cause K207 IP compressor shutdown for vibration and leaky zerk Action Taken Repaired compressor _ – _ _. _-------- – 14-381 Flare Relief 08/07/2014 7:30:00 am 11:30:00 pm 960 min No No Yes BP1\WALLC7 6000 ESD testing of plant and field devices. This shutdown the facility and then the facility was restarted. Determination Cause Action Taken Restarted the plant. . -- ---- ---- ---- --_ 14-380 Flare Relief 09/16/2014 1:45:00 pm 3:00:00 pm 75 min No Determination Cause Tandem Compressor down for mail. Gas header up to 630# Action Taken EOA & WOA cut rates _ No No 14-392 Flare Relief 09/27/2014 10:00:00 am 8:45:00 pm 645 min Yes No Determination Cause IP and LP compressor shut down due to hydration of gas plant outlet pipe Action Taken Equipment was restarted BPI\WALLC7 260 No BP1\WALGAB 18365 Total Volume (MSCF) 51472 Page 10 of 10 Generated 10/02/2014 2:36:16PM Hunt Jennifer L (DOA) From: AK, OPS PCC EOC TL [AKOPSPCCEOCTL@bp.com) Sent: Tuesday, September 16, 2014 11:36 AM To: Hunt, Jennifer L (DOA) Cc: Roby, David S (DOA); Ferguson, Victoria L (DOA); Castano, Alejandra; Benson, Gary A; Arthur, Gregory; Kruger, Dale O; AK, OPS GC3&PCC OSM; AK, OPS GC2 OSM; AK, OPS GC2 Facility OTL; AK, OPS PCC/EOC Process Engineer Subject: Flaring Events at GC2 To: Jennifer Hunt, AOGCC CC: Dave Roby, AOGCC CC: Victoria Ferguson, AOGCC iennifer.hunt@alaska.gov dave roby(aalaska.gov victoria ferguson2ilalaska gov From: Wendy Hiester, GPB Production Optimization Team Leader In the first half of September, the following flaring events occurred at GC2. The majority of the flaring occurred due to start-up of GC2: 9/13 A flaring event occurred at GC2 starting at 09/13/2014 16:58 and stopping at 09/13/2014 17:14 with a volume of 111 (MSCF). The event lasted for 16 minutes. Flaring was due to high transit line pressures caused by CCP compressor problems due to loss of tandems. The WOA reduced production rates to stop the flaring. 9/7 A flaring event occurred at GC2 starting at 09/07/2014 07:30 and stopping at 09/07/2014 23:30 with a volume of 6000 (MSCF). The event lasted for 960 minutes. The event had a volume greater than 5000 (MSCF). Flaring was caused by ESD testing of plant and field devices. GC2 was shut down and restarted for the ESD testing. The flaring stopped when GC2 was restarted. 9/3 A flaring event occurred at GC2 starting at 09/03/2014 14:00 and stopping at 09/03/2014 22:30 with a volume of 2833 (MSCF). The event lasted for 510 minutes. Flaring occurred when the K207 IP compressor was shutdown for repairs and high vibration. Flaring stopped when the compressor was restarted. 9/2 A flaring event occurred at GC2 starting at 09/02/2014 00:01 and stopping at 09/02/2014 23:59 with a volume of 11983 (MSCF). The event lasted for 1438 minutes. The flaring occurred when the IP compressor shut down because of a problem associated with GC2 start-up. The flaring stopped as start-up problems were resolved. 9/1 A flaring event occurred at GC2 starting at 09/01/2014 06:00 and stopping at 09/01/2014 23:49 with a volume of 11878 (MSCF). The event lasted for 1069 minutes. The flaring occurred when the IP compressor shut down because of a problem associated with GC2 start-up. The flaring stopped as start-up problems were resolved. Please let me know if you have any questions. Wendy Hiester (alt. Kellie Okonek) PCCIEOC Production Optimization TL external: (907) 659 4472 (BOC) / 5566 (PBOC) cell: (907) 227-7144 Harmony: 758 4404 Pager 574 (WOA - access # 4236) or 1890 (EOA - access #5100) e-mail akoasocceoctl@ba com Hunt, Jennifer L (DOA) From: AK, OPS PCC EOC TL [AKOPSPCCEOCTL@bp.comj Sent: Sunday, September 28, 2014 11:46 PM To: Hunt, Jennifer L (DOA) Cc: Ferguson, Victoria L (DOA); Roby, David S (DOA); Castano, Alejandra; Benson, Gary A; Arthur, Gregory; AK, HSSEE Env Adv West; Kruger, Dale O; AK, OPS GCI OSM; AK, OPS GCI Facility OTL; AK, OPS PCC EOC TL; AK, OPS CGF OTL, AK, OPS CCP CGF OSM; OPS FSI OSM; AK, PS FS1 FacilityH; OTL; AK, SSEE Env Adv East Facility OTL; AK, Subject: Gas flaring events at CGF, GCI INUmd FSI Categories: Attention To: Jennifer Hunt, AOGCC CC: Dave Roby, AOGCC CC: Victoria Ferguson, AOGCC iennifer hunt(oalaska.00v dave.robv@alaska.gov victoria ferauson(cDalaska.gov From: Kellie Okonek, GPB Production Optimization Team Leader A flaring event occurred at CGF starting at 09/24/2014 04:12 and stopping at 09/24/2014 05:23 with a volume of 13186 (MSCF). The event lasted for 71 minutes. The event had a volume greater than 5000 (MSCF), and was due to T/C 1805 shutdown due to pressure controller malfunction. Flaring stopped when the equipment was repaired and re -started. A flaring event occurred at GC1 starting at 09/23/2014 11:06 and stopping at 09/23/2014 18:08 with a volume of 3650 (MSCF). The event lasted for 422 minutes, and was due of depressurization of the PM2 line for maintenance. A flaring event occurred at GO starting at 09/22/2014 02:58 and stopping at 09/22/2014 08:50 with a volume of 6230 (MSCF). The event lasted for 352 minutes. The event had a volume greater than 5000 (MSCF), and was due to loss of K- 7001 compressor. Flaring stopped when K-7001 was repaired and re -started. A flaring event occurred at GC1 starting at 09/21/2014 04:04 and stopping at 09/21/2014 22:33 with a volume of 574 (MSCF). The event lasted for 1109 minutes, and was due to high transit pressure. Flaring stopped when gas production was stabilized.of 2485 A flaring event occurred t GC1 arting 0/2014 (MSCF). The event lastedat 16:30 14 th for 916minutes, 2 0 me andwas due to high and stopping pressure. F arinOg stopped wl hen gasu production was stabilized. A flaring event occurred at GC1 starting at 09/19/2014 11:05 and stopping at 09/19/2014 21:40 with a volume of 64 (MSCF). The event lasted for 635 minutes, and was due to high transit pressure. Flaring stopped when gas production was stabilized. A flaring event occurred at GC1 starting at 09/17/2014 00:00 and stopping at 09/17/2014 21:48 with a volume of 914 (MSCF). The event lasted for 1308 minutes, and was due to high transit pressure. Flaring stopped when gas production was stabilized. A flaring event occurred at GCI starting at 09/16/2014 00:00 and stopping at 09/16/201414:40when volume of tion 36 (MSCF). The event lasted for 880 minutes, and was due to high transit pressure. Flaring stoppedg P was stabilized..of 3649 A fring event occurred at GC1 ng at The event lasted for 1440 minutes, rand was due to high trans t presssur:00 and e. Flaring stopped when gasng at 09/1/2014 with a1production was . stabilized. A flaring event occurred at FS1 starting at 09/27/2014 04:00 and stopping at 09/27/2014 23:15 with a volume of 6417 (MSCF). The event lasted for 1155 minutes. The event had a volume greater than 5000 (MSCF), and was due to T/C 1802 shutdown for planned maintenance. t A flaring event occurred at GC2 starting at 09/27/201410:00 and stopping at 09/27/2014 20:45 with a volume of 18365 (MSCF). The event lasted for 645 minutes. The event had a volume greater stopped 5 whencompressorCF), and as duas e to I /LP compressor shutdown due to hydrate formation on outlet piping. g PP Please let me know if you have any questions. Kellie Okonek PCC/EOC Production Optimization TL Office: (907) 659-4472 Cell: (907) 382-1370 kopspcceoctlPbn.com 2 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION DECEIVED NOV 18 2014 AOGCC 1. Facility Number 0290000032 2. Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition October -2014 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 90.79% AURORA 640120 1.65° 8. Flared or vented 1 hour or less 270 BOREALIS 640130 6.12% ORION 640135 0.81% 9. Flared or vented more than 1 hour (see instr.) 0 POLARIS 640160 0.63% 10. Pilot and Purge 30,976 11. Assist Gas 0 12. Fuel gas used in lease operations. 631,047 13. Other (see instructions) 0 Official Use Only Authorization >i hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-12) 662,293 — Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 Commissioner Date 18. Transferred to: (Express as a negative #) CGF -16,859,522 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature dJf L9/ l .tA/YI'// Title Manager Production Taxes and Royalties Alaska Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 1 AAC25.235. Printed Name Diane Colley Phone (907) 564-5775 Date 14 /1171 Farm 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate HP txPLUKAI IUN IALASKA71N(-. PRUDHOE BAY UNIT - GC -2 GAS FLARING INCIDENT REPORT October 2014 Not required for unplanned events <= 1 hr TOTAL 0 See Attachments TOTAL 0 I V F. Lf NOV 1'20 F1614 Not required for unplanned events <= 1 hr ACTION TAKEN TO ELIMINATE CAUSE See Attachments DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 10/5/2014 0815-0850 262 See Attachments See Attachments 10/15/2014 1122-1153 8 Pilot Purge 30,976 TOTAL 270 TOTAL FLARED VOLUME 31,246 Planned Events Exceeding 1 Hour OR > 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 11/13/2014 2:39 PM TOTAL Unplanned Events < 1 Hour 0 Unplanned Events> 1 Hour 0 Planned Events < 1 hour and not 270 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 30,976 Assist 0 TOTAL FLARED VOLUME 31,246 11/13/2014 2:39 PM Flare Start Date 10/01/2014 Flare End Date 10/31/2014 GC2 Flare Report Total Volume (MSCF) 270 Report Numbe System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 14-406 Flare Relief 10/05/2014 8:15:00 am 8:50:00 am 35 min No No Determination Cause Spin cooled K-7000 for maintenance Action Taken No response taken as this was deemed to be of short duration. 14-423 Flare Relief 10/15/2014 112200 am 11'.53:00 am 31 min No No Determination Cause Test Bank, rate removed and vessel de -pressured for PSV isolation for PM's Action Taken Vessel depressured to ZERO psi. RECEIVi:u NOV 18 2014 AOGCC Yes BP1\EARLLC 262 Yes BPI\BRONTL 8 Total Volume (MSCF) 270 Generated 11/17/2014 9:25:27AM Page 9 of 10 DEC ] 6 2014 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION AOGCC FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. Month/Year of Disposition November -2014 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected U PRUDHOE 640150 93.20% AURORA 640120 1.45% 8. Flared or vented 1 hour or less 986 BOREALIS 640130 4.25% ORION 640135 0.62% 9. Flared or vented mom than 1 hour (see instr.) 231 POLARIS 640160 0.48% 10. Pilot and Purge 26,147 11. Assist Gas 0 12. Fuel gas used in lease operations. 649,354 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety � 3 MCF 14. TOTAL VOLUME (ITEMS 6-12) 676,718 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0,'� Commissioner Date 18. Transferred to: (Express as a negative #) CGF -20,017,929 , 19. Remarks: egoing, is true and correct to the best of my knowledge. I hereby certify thatn1m, Note: All volumes must be corrected Signature Title Manager Production Taxes and Royalties Alaska to pressure Of 14.65 psia and to a / // temperature of 60o F. Authority 20 Printed Name Diane Colley Phone (907) 564-5775 Date / L AAC25.235. ViL- I/T/lam Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -2 GAS FLARING INCIDENT REPORT November 2014 Page 8 Unplanned Events less than or equal to 1 hour TOTAL Unplanned Events < 1 Hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 11/11-12/2014 2350-0015 750 Not required for unplanned events <= 1 hr Not required for unplanned events <= 1 hr 11/16/2014 2159-2213 97 0 11/19/2014 1825-1835 35 Pilot Purge 11/19/2014 2050-2305 104 0 TOTAL 986 Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 11/17/2014 0007-0130 231 See Attachments See Attachments TOTAL 231 Planned Events Less Than or Equal 1 Hour AND <= 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 DATE TIME VOLUME DESCRIPTION OF INCIDENT&CAUSE See Attachments TOTAL 0 ACTION TAKEN TO ELIMINATE CAUSE See Attachments 12/11/2014 9:41 AM TOTAL Unplanned Events < 1 Hour 986 Unplanned Events > 1 Hour 231 Planned Events < 1 hour and not 0 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 26,147 Assist 0 TOTAL FLARED VOLUME 27,364 ACTION TAKEN TO ELIMINATE CAUSE See Attachments 12/11/2014 9:41 AM Flare Start Date 11/01/2014 Flare End Date 11/30/2014 GC2 Flare Report Total Volume (MSCF) 1217 Report Numbe System Date start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume RECEIVED DEC 16 2014 14-072 Flare Relief 11/17/2014 12:07:008M 1:30:00 am 83 min Yes No Determination Cause Ambient temperature swings resulted in fladrg and required cuts in production. Action Taken EOA & WOA reduced production rates. No BP1\STYVJW 231 Daily Volume (MSCF) 231 Total Volume (MSCF) 1217 Generated 12/02/2014 10:36:03AM Page 8 of 8 Hunt, Jennifer L (DOA) From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com> Sent: Sunday, November 23, 2014 9:46 AM To: Hunt, Jennifer L (DOA) Cc: Loepp, Victoria T (DOA); Roby, David S (DOA); Castano, Alejandra; Benson, Gary A; Arthur, Gregory; AK, HSSEE Env Adv West; Hauger, Wayne A; AK, OPS GC1 OSM; AK, OPS GC2 OSM; AK, OPS GC1 Facility OTL; AK, OPS GC2 Facility OTL, AK, OPS PCC EOC TL; AK, OPS FS1 Facility OTL; AK, OPS FSI OSM; Loader, Neil Subject: Gas flaring events at GC1,00FS1 To: Jennifer Hunt, AOGCC CC: Dave Roby, AOGCC CC: Victoria Ferguson, AOGCC iennifer.hunt(o)alaska.gov dave.robyno alaska.gov victoria.ferguson(a alaska.g ov From: Kellie Okonek, GPB Production Optimization Team Leader A flaring event occurred at GCI starting at 11/17/2014 21:00 and stopping at 11/17/2014 23:00 with a volume of 180 (MSCF). The event lasted for 120 minutes, and was due to cool down of K7000 LPS compressor for planned work. A flaring event occurred at GC1 starting at 11/18/2014 18:24 and stopping at 11/18/2014 23:07 with a volume of 460 (MSCF). The event lasted for 283 minutes, and was due to annex shutdown and associated flaring for depressure. A flaring event occurred at GC1 starting at 11/19/2014 09:00 and stopping at 11/19/2014 20:30 with a volume of 6580 (MSCF). The event lasted for 690 minutes. The event had a volume greater than 5000 (MSCF), and was due to trip of GLT compressor due to power load shedding s/d. Flaring stopped when power was restored and the plant restarted. A flaring event occurred at GC1 starting at 11/20/2014 01:00 and stopping at 11/20/2014 06:30 with a volume of 2920 (MSCF). The event lasted for 330 minutes, and was due to backout of LP/IP compressors from transit system due to performance issues. A flaring event occurred at GC1 starting at 11/21/2014 07:00 and stopping at 11/22/2014 with a volume of 6180 (MSCF). The event lasted for 1020 minutes. The event had a volume greater than 5000 (MSCF), and was due to backout of LP/IP compressors from transit system due to performance issues. A flaring event occurred at GC2 starting at 11/17/2014 00:07 and stopping at 11/17/2014 01:30 with a volume of 231 (MSCF). The event lasted for 83 minutes, and was due to ambient -driven fluctuations in transit gas line pressure. Flaring stopped when production rates were cut. A flaring event occurred at FS1 starting at 11/19/2014 15:00 and stopping at 11/19/2014 17:45 with a volume of 974 (MSCF). The event lasted for 165 minutes, and was due to STV/IP 1802 compressor shutdown to allow for testing of new STV/IP compressor 1825. A flaring event occurred at FS1 starting at 11/21/2014 08:00 and stopping at 11/21/2014 18:50 with a volume of 3611 (MSCF). The event lasted for 650 minutes, and was due to STV/IP 1802 compressor shutdown to allow for testing of new STV/IP compressor 1825.. A flaring event occurred at FS1 starting at 11/22/2014 10:25 and stopping at 11/22/2014 19:46 with a volume of 6234 (MSCF). The event lasted for 561 minutes. The event had a volume greater than 5000 (MSCF), and was due to SNIP 1802 compressor shutdown to allow for testing of new STV/IP compressor 1825. Please let me know if you have any questions. Kellie Okonek PCC/EOC Production Optimization TL Office: (907) 659-4472 Cell: (907) 382-1370 akopspcceoctl@bp.com R" C=aVED STATE OF ALASKA AN 16 2015 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 0290000032 2. Facility Name PBU GC 2 3. Field PBU - WOA 4. Operator BP 5. MonthNear of Disposition December -2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume, 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected 0 PRUDHOE 640150 92.28% AURORA 640120 2.40% 8. Flared or vented 1 hour or less 101 BOREALIS 640130 4.13% ORION 640135 0.62% 9. Flared or vented more than 1 hour (see instr.) 1,088 POLARIS 640160 0.57% 10. Pilot and Purge 26,145 11. Assist Gas 0 12. Fuel gas used in lease operations. 649,399 Other (see instructions) 0 Official Use Only13. Authorization >1 hr: Safety / O qG / !!�, GG MCF 14. TOTAL VOLUME (ITEMS 6-12) 676,733 Lease Use MCF 15, NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas 0 Waste: MCF 17. Transferred from: 0 Z —147 /S— 18. Transferred to: (Express as a negative #) CGF -20,952,933 Commissioner Date 19. Remarks: I hereby certify that the foregoipg is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature li Title Manager Production Taxes and Roygities Alaska to pressure of 14.65 psia and to a % /� temperature of 60o F. Authority 20 Printed Name Diane Colla ( Phone 907) 564-5775 Date AAC25.235. VTI— Z/�/r5 Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate BP EXPLORATION (ALASKA) INC. PRUDHOE BAY UNIT - GC -2 GAS FLARING INCIDENT REPORT December 2014 Events less than or equal to 1 JAN 1 6 2015 Not required for unplanned events <=1 hr Not required for unplanned events <= i hr TOTAL 0 Unplanned Events greater than 1 hour DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE 12/5/2014 1432-1726 1,088 See Attachments See Attachments TOTAL 1,088 Page 7 DATE 12/15/2014 TIME 1031-1100 TOTAL VOLUME DESCRIPTION OF INCIDENT & CAUSE 101 See Attachments 101 ACTION TAKEN TO ELIMINATE CAUSE See Attachments Planned Events Exceeding 1 Hour OR > 5,000 mcf DATE TIME VOLUME DESCRIPTION OF INCIDENT & CAUSE ACTION TAKEN TO ELIMINATE CAUSE See Attachments See Attachments TOTAL 0 TOTAL Unplanned Events < 1 Hour 0 Unplanned Events> 1 Hour 1,088 Planned Events < 1 hour and not 101 exceeding 5,000 MCF Planned Events > 1 hour or 0 exceeding 5,000 MCF Pilot Purge 26,145 Assist 0 TOTAL FLARED VOLUME 27,334 1/14/2015 10:49 AM Flare Start Date 12/012014 V +. q ice. to I... Flare End Date 12/31/2014 GC2 Flare Report ?r Total Volume (MSCF) 1189 Report Numbs System Date Start Time Stop Time Duration Intermittent Black Smoke Planned Reported By Volume 14-502 Flare Relief 12/05/2014 2:32:00 pm 5:26:00 pm 174 min Yes No No BP1\GILLSJ 1088 Determination Cause IP compressor shut down because ofa problem associated with Startup of production from plant shutdown. Action Taken Flaring was permitted to continue while GC operations personnel attempted to restart the equipment. Daily Volume (MSCF) 1088 14-513 Flare Relief 12/15/2014 10:31:00 am 11:00:00 am 29 min No No Yes BP1\PAOLINJM 101 Determination Cause Depressure 0-03 in prep for safe out. Field crew maintenance -dead leg removal. Action Taken Flowline depressured and test bank returned to service. Daily Volume (MSCF) 101 Total Volume (MSCF) 1189 Generated 01/08/2015 9:27:01AM Page 7 of 8 Hunt, Jennifer L (DOA) From: AK, OPS PCC EOC TL <AKOPSPCCEOCTL@bp.com> Sent: Wednesday, December 10, 2014 6:20 PM To: Hunt, Jennifer L (DOA) Cc: Loepp, Victoria T (DOA); Roby, David S (DOA); Castano, Alejandra; Benson, Gary A; Arthur, Gregory; AK, HSSEE Env Adv West; Hauger, Wayne A; AK, OPS GCI OSM; AK, OPS GQ Facility OTL; AK, OPS GC2 OSM; AK, OPS GC2 Facility OTL, AK, OPS GC3&PCC OSM; AK, OPS GC3 Facility & Field OTL Subject: Flaring Events at GC1,�and GC3 Categories: Attention To: Jennifer Hunt, AOGCC CC: Dave Roby, AOGCC CC: Victoria Ferguson, AOGCC iennifer.hunt(o)alaska.gov dave.robvaalaska.gov victoria.ferguson(rDalask a.gov From: Wendy Hiester. Production Optimization Team Leader A flaring event occurred at GC3 starting at 12/08/2014 05:32 and stopping at 12/08/2014 12:10 with a volume of 1023 (MSCF). The event lasted for 398 minutes and occurred when the Wet Gas compressor shutdown because of control/instrumentation failure associated with a faulty instrumentation. Flaring was permitted to continue while GC operations personnel attempted to restart the equipment. Flaring stopped when the compressor was restarted successfully. A flaring event occurred at GC2 starting at 12/05/2014 14:32 and stopping at 12/05/2014 17:26 with a volume of 1088 (MSCF). The event lasted for 174 minutes and occurred when the IP compressor was shut down because of a problem associated with re -start of production following plant shutdown. Flaring was permitted to continue while GC operations personnel attempted to restart the equipment. Flaring stopped when the compressor was restarted successfully. A flaring event occurred at GCI starting at 12/05/2014 14:30 and stopping at 12/05/2014 23:00 with a volume of 5050 (MSCF). The event lasted for 510 minutes. The event had a volume greater than 5000 (MSCF) and occurred when GC2 shut down causing the LPAP compressors to lose flow. Flaring stopped when GC2 started flowing oil to GC 1 and gas rate increased so that forward flow was reestablished in the LP/IP machines. Please let me know if you have any questions, Wendy Hiester (alt. Kellie Okonek) PMEOC Production Optimization TL external: (907) 659 4472 (BOC) / 5566 (PBOC) cell: (907) 227-7144 Harmony: 758 4404 Pager 574 (WOA - access # 4236) or 1890 (EOA - access #5100) e-mail akor)spcceoctl@bo.com