Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutMGS C Platform / XTO Energy
STATE OF ALASKA
AOGCC
GAS DISPOSITION FILES
YEAR: 2004
FACILITY: MGS C Platform
OPERATOR: XTOENERGYINC
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Operator
Platform "C"
XTO Energy
Disposition Volume MCF*
1. Sold 0
2. Reinjected 0
3. Flared or vented less than 1 hour 0
4. Flared or vented greater than 1 hour 587
(Supp. rpt. required-See 20MC25.235)
5. Pilot and purge 1550
6. Used for lease operations 4841
7. Other 0
TOTAL items 1 -7 6978
8. NGL gas equivalent produced 0
9. Purchased gas 23698
10. Transferred from: N/A
11. Transferred to: N/A
Remarks: #9 Purchased Gas was purchased from Marathon.
I hereby certify that the foregoing is true and correct to the best of my knowledge.
February 19, 2004 Ov
Signature ~J1.~ ~ Dist. Admin. Mgr.
Form 10-422
Rev. 4/95
Fields
Month/Year of Disposition
Jan-2004
Middle Ground Shoal
* Indicate contribution of each pool to total.
Pool Code Percent
"A" Pool 524110 0
"B, C & D" Pool 524112 0
/ "E, F & G" Pool 524114 100
1. Safety S-~7 MCF ;Jß~
2. Lease Use MCF
3. Conserv. Purposes MCF
Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature
of 60 degrees F. Report due by the 20th of the month following the month of
disposition. Authority 20 MC 25.235.
Questions may be directed to Bill Miller at (907) 776-2511.
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen
stripping tower gas and gas surges from
1/1/0412:00 AM 1/31/0411:59 PM 587 y y well "heading" (gas lift operations). Operational Safety flare
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
MGS C Platform
3. Field
Middle Ground Shoal
Volume MCF 20.
4. Operator
1. Facility Number
1330000016
2. Facility Name
Disposition
6. Sold
7. Reinjected
8. Flared or vented 1 hour or less
9. Flared or vented more than 1 hour (see instr.)
470
10. Pilot and Purge
1450
11. Used for lease operations (specify in Remarks)
3227
12. Other (see instructions)
13. TOTAL VOLUME (ITEMS 6-12)
5147
14. NGL Gas Equivalent
15. Purchased gas
22549
16. Transferred from:
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature_~
G.-.~
Title District Administrative Manaqer
o
Pool Name
Pool Code Percent
524110 0
524112 0
524114 100
"A" Pool
o
"B", "C", & "D" Pool
"E", "F" t & "G" Pool
o
o
o
o
o
Printed Name
William A. Miller
Phone (907) 776-2511 Date
May 5, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
AAC25.235.
Form 10-422 Rev. 1/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
..
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Watelilood oxygen
stripping tower gas and gas surges from
2/1/0412:00 AM 2/29/04 11: 59 PM 470 Y Y well "heading" (gas lift operations). Operational Safety flare
./
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
MGS C Platform
3. Field
Middle Ground Shoal
Volume MCF 20.
4. Operator 5. Month/Year of Disposition
XTO Energy, Inc. February-04
For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
1. Facility Number
1330000016
2. Facility Name
Disposition
6. Sold
o
liB", "C", & "0" Pool
"E", "F", & "G" Pool
Pool Code Percent
." 524110 0
524112 0
524114 100
o
Pool Name
7. Reinjected
"A" Pool
8. Flared or vented 1 hour or less
o
14. NGL Gas Equivalent
r'
9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
11. Used for lease operations (specify in Remarks)
12. Other (see instructions)
Safety
13. TOTAL VOLUME (ITEMS 6-12)
MCF
Lease Use
o
MCF
Conservation
15. Purchased gas
16. Transferred from:
o
MCF
22981
17. Transferred to: (Express as a negative #)
o
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Printed Name
William A. Miller
Phone (907) 776-2511
Date
March 16, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
AAC25.235.
Signature
~(l~
Title District Administrative Manaqer
Form 10-422 Rev. 1/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
,
¿
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour DescriDtion of Incident Category Reason Actions Taken Minimize Recurrence
Safety flare: WatertJood oxygen
stripping tower gas and gas surges from
2/1/04 12:00 AM 2/29/04 11 :59 PM 431 Y Y well "heading" (gas lift operations). Operational Safety flare
~
...
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
MGS C Platform
3. Field
Middle Ground Shoal
Volume MCF 20.
4. Operator 5. Month/Year of Disposition
XTO Energy, Inc. March-04
For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
1. Facility Number
1330000016
2. Facility Name
Disposition
6. Sold
7. Reinjected
8. Flared or vented 1 hour or less
9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
11. Used for lease operations (specify in Remarks)
4489
12. Other (see instructions)
13. TOTAL VOLUME (ITEMS 6-12)
6758
14. NGL Gas Equivalent
15. Purchased gas
22578
16. Transferred from:
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature ~ Cl ~
o
Pool Name
Pool Code Percent
524110 0
524112 0
524114 100
"A" Pool
o
"B", "C", & "D" Pool
"E", "F", & "Goo Pool
o
o
o
o
o
Printed Name
William A. Miller
Phone (907) 776-2511 Date
April 16, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
AAC25.235.
Title District Administrative Manaqer
Form 10-422 Rev. 1/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
r
*
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Begin End MCF Planned? 1 Hour Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen
stripping tower gas and gas surges from
3/1/0412:00 AM 3/31/0411:59 PM 719 Y y well "heading" (gas lift operations). Operational Safety flare
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000016
2. Facility Name
MGS C Platform
3. Field
Middle Ground Shoal
Volume MCF 20.
4. Operator 5. Month/Year of Disposition
XTO Energy, Inc. April-04
For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
Disposition
6. Sold
o
Pool Name
Pool Code Percent
524110 0
524112 0
524114 100
7. Reinjected
"A" Pool
o
"8", "C", & "0" Pool
"E", "F", & "G" Pool
8. Flared or vented 1 hour or less
o
9. Flared or vented more than 1 hour (see instr.)
794
10. Pilot and Purge
1500
11. Used for lease operations (specify in Remarks)
6799
12. Other (see instructions)
o
13. TOTAL VOLUME (ITEMS 6-12)
9094
14. NGL Gas Equivalent
o
15. Purchased gas
18862
16. Transferred from:
o
17. Transferred to: (Express as a negative #)
o
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
(þ~ Ck ~
Printed Name
William A. Miller
Phone (907) 776-2511 Date
May 18, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
MC25.235.
Signature
Title District Administrative Manaqer
Form 10-422 Rev. 1/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen
stripping tower gas and gas surges from
4/1/04 12:00 AM 4/30/04 11 :59 PM 794 Y Y well "heading" (gas lift operations). Operational Safety flare
-.
.. .
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DIS·POSITION
-
1. Facility Number
1330000016
2. Facility Name
MGS C Platform
3. Field
Middle Ground Shoal
Volume MCF 20.
4. Operator 5. Month/Year of Disposition
XTO Energy, Inc. May-04
For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
Disposition
6. Sold
o
Pool Name
Pool Code Percent
524110 0
524112 0
524114 100
"A" Pool
7. Reinjected
o
"B", "C", & "0" Pool
"E", "F", & "G" Pool
8. Flared or vented 1 hour or less
o
9. Flared or vented more than 1 hour (see instr.)
991
10. Pilot and Purge
1550
11. Used for lease operations (specify in Remarks)
6345
12. Other (see instructions)
o
Authorization >1 hr:
Safety
14. NGL Gas Equivalent
o
CQnservation
Cfq{ MCF
-::JP-¥L
MCF
MCF
MCF
7 1-
13. TOTAL VOLUME (ITEMS 6-12)
8886
Lease Use
15. Purchased gas
16. Transferred from:
o
18578
17. Transferred to: (Express as a negative #)
o
18. Remarks:
Ihe::::~t~z:~otJct~~e
Printed Name
William A. Miller
Phone (907) 776-2511 Date
June 11, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of60o F. Authority 20
AA C25. 235.
Title District Administrative Manaqer
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
¿,,-
..
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Bellin End MCF Planned? 1 Hour Description of Incident Catellorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen
stripping tower gas and gas surges from
5/1/04 12:00 AM 5/31/0412:00 AM 991 Y Y well "heading" (gas lift operations). Operational Safety flare
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000016
12.
Facility Name
MGS C Platform
Disposition
3. Field
Middle Ground Shoal
Volume MCF 20.
14. Operator 15. MonthNear of Disposition
1 XTO Energy, Inc. I June-04
For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
o
Pool Name
Pool Code Percent
524110 C
524112 0
524114 10C
7. Reinjected
"A" Pool
o
118", IIC", & IIDII Pool
IIEII, !IF", & "G" Pool
8. Flared or vented 1 hour or less
o
9. Flared or vented more than 1 hour (see instr.)
984 ./
10. Pilot and Purge
1500
11. Used for lease operations (specify in Remarks)
6133
ki}};·iVi~/if<fii/}i/iiii;i!:.·ii/. :/ // ............V/iii. i/;:.!··.!;/!:!
0 Authorization> 1 hr: qa+ MCF 051-
S¥Ÿ\. 8611 Safety
8616 MCF
Lease Use
0 /. þonservation MCF
-
18060 Was;tr ,/". 1./"7 MCF
0 l/lY~ ~ Ø'&oV
[ 7 \. Co~ Issioner I ~ate ,
0
12. Other (see instructions)
13. TOTAL VOLUME (ITEMS 6-12)
14. NGL Gas Equivalent
15. Purchased gas
16. Transferred from:
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature~ ~
Printed Name William A. Miller
Phone (907) 776-2511 Date
July 9, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
AAC25.235.
Title District Administrative Manaqer
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
..
..
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen stripping
tower gas and gas surges from well
6/1/04 12:00 AM 6/30/04 12:00 AM 984 Y y "heading" (gas lift operations). Operational Safety flare
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000016
12. Facility Name
1 MGS C Platform
Disposition
3. Field
Middle Ground Shoal
Volume MCF 20.
14. Operator 15. MonthNear of Disposition
I XTO Energy, Inc. 1 July-04
For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
11. Used for lease operations (specify in Remarks)
0 Pool Name Pool Code Percent
"A" Pool 524110 0
0 "B", liCIT, & "0" Pool 524112 0
"EII, !lFII, & IIGII Pool 524114 100
0
921 v
1550
6112
x'i!!;;';!:i:.:x.....··.:::;;x;.: :{¡i;{:{{i::;~ :(::ii; ';.,::. :E::·:.:·/:
0 Authorization> 1 hr: qz MCF -J~
~ Safety
A-~",~ &58.~~ MCF
I Lease Use
0 /J MCF
Conservation
18789 W~>"-,\ r I MCF
0 (1--If AA ./ 9 Ii ht./
\..,./ ./ Comiì'!mSìoner / /bate'
0 ,
7. Reinjected
8. Flared or vented 1 hour or less
9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
12. Other (see instructions)
13. TOTAL VOLUME (ITEMS 6-12)
14. NGL Gas Equivalent
15. Purchased gas
16. Transferred from:
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is ~d correct to the best of my knowledge.
Signature !jf;1dl" (j¡ut:~
Printed Name William A. Miller
Phone (907) 776-2511
Date
August 18, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
AAC25.235.
Title District Administrative Manaqer
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Watertlood oxygen stripping
tower gas and gas surges from well
7/1/04 12:00 AM 7131/0412:00AM 921 Y y "heading" (gas lift operations). Operationai Safety flare
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 12. Facility Name 3. Field 14. Operator 15. Month/Year of Disposition
1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. August-04
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold Pool Name Pool Code
0 Percent
"A" Pool 524110 0
7. Reinjected "811, IICU, & "D" Pool C
0 524112
IIEII, IIF', & IIGII Pool 524114 10C
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.) ./
1230
10. Pilot and Purge 1550
11. Used for lease operations (specify in Remarks) 6726
12. Other (see instructions) 'dtP( PP:qj;', :,pX'ÞX ("'Me; ::PP
0 Authorization> 1 hr: MCF
Safety 1L..-3°
13. TOTAL VOLUME (ITEMS 6-12) 9506 MCF
Lease Use
14. NGL Gas Equivalent 0 /J MCF
~ Conservation
15. Purchased gas 18805 ( Wasyr. , //.J £ MCF
16. Transferred from: / 4- J/tú (O;f51ðV
0 . ,
17. Transferred to: (Express as a negative #) '-"" ~om~ioner I Dåte ,
0 '-'
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature~ ~ a¡~ Note: All volumes must be corrected
Title District Administrative Manaqer to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
Printed Name William A. Miller Phone (907) 776-2511 Date September 14, 2004 AAC25.235.
:Jß¡:J--
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Watertlood oxygen stripping
tower gas and gas surges from well
8/1/04 12:00 AM 8/31/0412:00 AM 1230 Y y "heading" (gas lift operations). Operational Safety flare
...
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 12. Facility Name 3. Field 14. Operator 15. MonthNear of Disposition
1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. September-04
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold 0 Pool Name Pool Code Percent
"A" Pool 524110 C
7. Reinjected 0 118", "C", & "0" Pool 524112 a
IIE", IIF", & IIGU Pool 524114 100
8. Flared or vented 1 hour or less 0
9. Flared or vented more than 1 hour (see instr.) 988 1./
10. Pilot and Purge 1500
11. Used for lease operations (specify in Remarks) 6249
y;;:>;; ;.;;;; ··;;;c;;;;:fP;;ff :;; c; :oj; .,;,.;; iJiJ;:U,'PYP;FJ':!:;
12. Other (see instructions) 0 Authorization> 1 hr: MCF
Safety 16ß -:Jß
13. TOTAL VOLUME (ITEMS 6-12) 8737 MCF
!¡.ease Use
/. \
14. NGL Gas Equivalent 0 I~nservation MCF
~
15. Purchased gas 18507 ( Wasto/' I U J'. / j MCF
16. Transferred from: 0 / h,'~ It/JIG
17. Transferred to: (Express as a negative #) l/ fiommissioner / /Date!
0
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
I 1.\...... ' (1 II ... -L. Note: All volumes must be corrected
Signature JmJ"5o, j AÆ.~ Title District Administrative Manaqer to pressure of 14.65 psia and to a
ð temperature of 600 F. Authority 20
Printed Name William A. Miller Phone (907) 776-2511 Date October 15, 2004 AAC25.235.
¡z--
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen strtpping
tower gas and gas surges from well
9/1/0412:00 AM 9130/04 12:00 AM 988 Y Y "heading" (gas lift operations). Operational Safety flare
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000016
12. Facility Name
I MGS C Platform
Disposition
3. Field
Middle Ground Shoal
Volume MCF 20.
6. Sold
7. Reinjected
0
0
0
922 ...
1550
8. Flared or vented 1 hour or less
9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
11. Used for lease operations (specify in Remarks)
7308
12. Other (see instructions)
13. TOTAL VOLUME (ITEMS 6-12)
9780
14. NGL Gas Equivalent
15. Purchased gas
19907
16. Transferred from:
17. Transferred to: (Express as a negative #)
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature_~ ~/~
14. Operator 15. Month/Year of Disposition
I XTO Energy, Inc. October-04
For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
Pool Name
Pool Code Percent
524110 0
524112 C
524114 10C
"A" Pool
IIB", "CU, & "D" Pool
IIEII, !IF", & IIG" Pool
o
I' . >.., ':,'. ' . .
Authorization> 1 hr:
Q7t.-
.'
. ,
MCF
-::f¿fl-
Safety
o
Lease Use
~ ~onservation
~I/j ~
W¢e: / .I J J'
l j )V/Ut
I / Commissi~ ~
'-'"
MCF
MCF
o
. Ðt1CF
,-z!Æðý-
I 0, te '
o
Date November 11, 2004
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
AAC25.235.
Printed Name William A. Miller
Title District Administrative Manager
Phone (907) 776-2511
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Description of Incident CateClorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen stripping
tower gas and gas surges from well
1011/0412:00 AM 10131/0412:00 AM 922 Y Y "heading" (gas lift operations). Operational Safety flare
~
4\
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 12. Facility Name 3. Field 14. Operator 15. Month/Year of Disposition
1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. November-04
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold Pool Name Pool Code Percent
0
"A" Pool 524110 0
7. Reinjected
0 IIB", IIC", & "0" Pool 524112 0
"E", "F", & IIGII Pool 524114 100
8. Flared or vented 1 hour or less
0
9. Flared or vented more than 1 hour (see instr.) 1100 v
10. Pilot and Purge 1500
11. Used for lease operations (specify in Remarks) 7875
x: .'iT'::,,">:' f" ~fj;f::FUfF'df
12. Other (see instructions) 0 Authorization> 1 hr: MCF
Safety {¡tOO
13. TOTAL VOLUME (ITEMS 6-12) 10475 ~u1e MCF
14. NGL Gas Equivalent
0 ~'.£ r;;¡sfation MCF
15. Purchased gas
20301 wø: / /1) ,~ MCF
16. Transferred from: l I (/þt{ 1-// ~-f)~
0 ,
L/ ~mf9issio~ Date
17. Transferred to: (Express as a negative #) 0 /'
18. Remarks:
I hereby certify that the foregoing is true and correct to the best of my knowledge.
IJJ:dL ú.-~ Note: All volumes must be corrected
Signature Title District Administrative Manaqer to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
Printed Name William A. Miller Phone (907) 776-2511 Date December 13, 2004 AAC25.235.
.:Qr-
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beain End MCF Planned? 1 Hour Descriation of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen stripping
tower gas and gas surges from well
11/1/0412:00AM 11/30/04 12:00 AM 1100 Y y "heading" (gas lift operations). Operational Safety flare
· .
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number 12. Facility Name 3. Field 14. Operator 15. MonthNear of Disposition
1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. December-Q4
Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold 0 Pool Name Pool Code Percent
"A" Pool 52411 C 0
7. Reinjected
0 118", "C", & "0" Pool 524112 0
IIE", IIF\ & IIGII Pool 524114 100
8. Flared or vented 1 hour or less 0
9. Flared or vented more than 1 hour (see instr.) 1030 11
10. Pilot and Purge 1550 /
11. Used for lease operations (specify in Remarks) 9413
'/.,
12. Other (see instructions) :;;'/;';'
0 Authorization > 1 hr: MCF
Safety '0.30 ~
13. TOTAL VOLUME (ITEMS 6-12) 11993 MCF
Lease Use
14. NGL Gas Equivalent 0 ~-/ ~servation MCF
15. Purchased gas
19249 I./'¢:ste: / /Jt./ ~ ./1 , M9J= --
16. Transferred from: 0 \... I j y~~ úzl / r$
17. Transferred to: (Express as a negative #) \...,./" ~missioner I D~e
0
18. Remarks:
,
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature (~~ Note: All volumes must be corrected
Title District Administrative Manaqer to pressure of 14.65 psia and to a
temperature of 600 F. Authority 20
Printed Name William A. Miller Phone (907) 776-2511 Date January 13, 2005 AAC25.235.
ßt'J.--
Form 10-422 Rev. 4/2004
INSTRUCTIONS ON REVERSE SIDE
Submit in Duplicate
Excess Flare Log Report
Facility Name: Platform C
Date & Time Event Gas Over Corrective Steps Taken to
Beoin End MCF Planned? 1 Hour Descriotion of Incident Cateaorv Reason Actions Taken Minimize Recurrence
Safety flare: Waterflood oxygen stripping
tower gas and gas surges from well
12/1/0412:00 AM 12/31/0412:00 AM 1030 Y y "heading" (gas lift operations). Operational Safety flare