Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutMGS C Platform / XTO Energy INC STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2008 FACILITY: MGS C Platform OPERATOR: XTO ENERGY INC • F = z STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. January-08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Q Pool Name Pool Code Percent - "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 682 10. Pilot and Purge 1550 11. Used for lease operations (specify in Remarks) 3622 12. Other (see instructions) Official Use Only 0 Authorization >1 hr: Safety 'g-?i MCF 13. TOTAL VOLUME (ITEMS 6 -12) FEB 2 0 2008 5854 Lease Use MCF 14. NGL Gas Equivalent Ah On & G �.. O.mir� IEl00 0 MCF Conservation 15. Purchased gas Anchora 25822 Waste: MCF 16. Transferred from: Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify that t ore• •i; • is true and correct to the best of my knowledge. Signature �/ / / �, Note: All volumes must be corrected �/ .1 _J Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date February 11, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare Waterflood oxygen stripping tower gas and gas surges from 1/1/08 12:00 AM 1/31/08 12.00 AM 682 Y Y well "heading" (gas lift operations). Operational Safety flare STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. February-08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 639 10. Pilot and Purge 1450 11. Used for lease operations (specify in Remarks) 3541 Official Use Only 12. Other (see instructions) 0 Authorization >1 hr: MCF Safety 3 7 13. TOTAL VOLUME (ITEMS 6 -12) 5630 MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 23421 Waste: MCF 16. Transferred from: 0 4-7-OF Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify = thet'o, r •oing is tr - and rect to the best of my knowledge. Note: All volumes must be corrected Signat re f,( ��„` Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date March 13, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate r—.,W Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare: Waterflood oxygen stripping tower gas and gas surges from 2/1/08 12:00 AM 2/29/08 12:00 AM 639 Y Y well "heading" (gas lift operations). Operational Safety flare STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. March -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 433 10. Pilot and Purge 1450 11. Used for lease operations (specify in Remarks) 1529 12. Other (see instructions) Official Use Only 0 Authorization >1 hr: MCF Safety 13. TOTAL VOLUME (ITEMS 6 -12) 3412 . . mCF Lease Use .. --, - 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 24252 Waste: MCF 16. Transferred from: / / I / 0 Mi.. / - 21 2 -ed4 Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify at the for,:.. mg is tr-- ' orrect to the best of my knowledge. Note: All volumes must be corrected Sign- ure ' � , 1 Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date April 15, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate J Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare: Waterflood oxygen stripping tower gas and gas surges from 3/1/08 12:00 AM 3/31/08 12:00 AM 433 Y Y well "heading" (gas lift operations) Operational Safety flare II i < STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION _ 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. April -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of _ Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 520 10. Pilot and Purge 1500 11. Used for lease operations (specify in Remarks) - 2312 12. Other (see instructions) Official Use Only 0 Authorization >1 hr: MCF Safety 13. TOTAL VOLUME (ITEMS 6 -12) E 4332 Lease Use ? > MCF ' `y p+�� Aq V 14. NGL Gas Equivalent MAY 4 .� ��� 0 Conservation MCF 15. Purchased 9 as mom oil a me; cons. cmmission 24636 Waste: qe,14„-- Q MCF 16. Transferred from: �� "� 0 / !P !D --(9e J Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify th- e fore ' a ng is true - d cor - ct to the best of my knowledge. �� �� / Note: All volumes must be corrected Signature .� Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date May 14, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate irr Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare: Waterflood oxygen stnpping tower gas and gas surges from 4/1/08 12.00 AM 4/30/08 12:00 AM 520 V Y well "heading" (gas lift operations). Operational Safety flare ill I I ill - STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. May -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B", "C", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 601 10. Pilot and Purge 1550 11. Used for lease operations (specify in Remarks) 2265 Official Use Only 12. Other (see instructions) 0 - Authorization >1 hr: MCF Safety 13. TOTAL VOLUME (ITEMS 6 -12) 4416 MCF Lease Use r t , i .. 1j(,r 14. NGL Gas Equivalent 0 > MCF Conservation 15. Purchased gas 23622 Waste: MCF 16. Transferred from: 1) i _ 0 %�. �..I ?- q -D$ Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify that • oreg i ! is true . nd corr; to the best of my knowledge. Note: All volumes must be corrected Signature F / �/ / t / / T itle Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date June 13, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category , Reason Actions Taken Minimize Recurrence Safety flare: Waterflood oxygen stripping tower gas and gas surges from Continuing operational efforts to minimize 5/1/08 12'00 AM 5/31/08 12:00 AM 601 Y Y well "heading" (gas lift operations). Operational Safety flare volumes Flare meter has been installed . STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. June -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 539 10. Pilot and Purge 1500 11. Used for lease operations (specify in Remarks) 2113 12. Other (see instructions) Official Use Only 0 Authorization >1 hr: MCF Safety .3 / 13. TOTAL VOLUME (ITEMS 6 -12) 4152 MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 23088 Waste: MCF .�L. / / �a�Li / 16. Transferred from: 0 �—[ 8 _ 6 8 � Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: . I hereby certify at the f going is rue an, orrect to the best of my knowledge. Note: All volumes must be corrected signs re / % Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date July 14, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare: Waterf lood oxygen stripping tower gas and gas surges from Continuing operational efforts to minimize 6/1/08 12:00 AM 6/30/08 12:00 AM 539 Y Y well "heading" (gas lift operations). Operational Safety flare volumes. Flare meter has been installed. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. July -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 608 10. Pilot and Purge 1550 11. Used for lease operations (specify in Remarks) 2908 Official Use Only 12. Other (see instructions) 0 Authorization >1 hr: MCF Safety 1 6 ,,,✓ 13. TOTAL VOLUME (ITEMS 6 -12) 5066 !� MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 22687 Waste: MCF 16. Transferred from: 0 '919 Og Commissioner ee Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: - I hereby certify that - forego • is true d corre , • the best of my knowledge. Note: All volumes must be corrected Signature �/ Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date August 12, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare Waterflood oxygen stnpping tower gas and gas surges from Continuing operational efforts to minimize 711/08 12.00 AM 7/31/08 12 00 AM 608 Y Y well "heading" (gas lift operations). Operational Safety flare volumes. Flare meter has been installed. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. August -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected "A" Pool 524110 0 0 "B" "C" & "D" Pool 524112 0 "E ", "F ", & "G" Pool 8. Flared or vented 1 hour or less 524114 100 0 9. Flared or vented more than 1 hour (see Instr.) 850 10. Pilot and Purge 1550 11. Used for lease operations (specify in Remarks) 3985 12. Other (see instructions) horiz ';: ,. Q.fficial. Use O IY . 0 Authorization >1 hr: MCF Safety t ? 1 7 1 13. TOTAL VOLUME (ITEMS 6 -12) 6385 Lease Use MCF / 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 22046 Waste: MCF 16. Transferred from: p ,„,L,„,... P At ...L.140 `0 -2- D 17. Transferred to: (Express as a negative #) 0 Commissioner Date 18. Remarks: I hereby certify that the • - .oing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature // M ' / Title Producton Analyst to pressure of 14.65 psia and to a L / temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date October 28, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. August -08 - Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 209 10. Pilot and Purge 1550 11. Used for lease operations (specify in Remarks) -187 12. Other (see instructions) Official Use Only 0 Authorization >1 hr: MCF Safety 13. TOTAL VOLUME (ITEMS 6 -12) 1572 MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 26859 Waste: MCF 16. Transferred from: 0 Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify th a for •ing is true and co - ct to the best of my knowledge. Note: All volumes must be corrected Signa re Adt 4, / Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date September 11, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate • Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare. Waterflood oxygen stripping tower gas and gas surges from Continuing operational efforts to minimize 8/1/08 12'00 AM 8/31/08 12:00 AM 209 Y Y well "heading" (gas lift operations). Operational Safety flare volumes Flare meter has been installed. VOW STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 12. MGS C Platform Middle Ground Shoal XTO Energy, Inc. September -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B", "C", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 430 10. Pilot and Purge 1500 11. Used for lease operations (specify in Remarks) 1138 12. Other (see instructions) Official Use Only 0 Authorization >1 hr: MCF ...3 Safety 3Z) 13. TOTAL VOLUME (ITEMS 6 -12) 3067 c � MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 23030 Waste: MCF 16. Transferred from: 0 Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify th a foreg ;"ng is tru and corre o the best of my knowledge. / Note: All volumes must be corrected Signatu Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date October 16, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare: Waterflood oxygen stripping tower gas and gas surges from Continuing operational efforts to minimize 9/1/08 12:00 AM 9/30/08 12:00 AM 430 Y Y well "heading" (gas lift operations). Operational Safety flare volumes. Flare meter has been installed. • II i + STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. October -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see instr.) 293 10. Pilot and Purge 1550 11. Used for lease operations (specify in Remarks) - 467 12. Other (see instructions) Official Use Only �i, 0 Authorization >1 hr: Q MCF ! ;L��^� Safety C 13. TOTAL VOLUME (ITEMS 6 -12) 2309 MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 27556 Waste: MCF 16. Transferred from: 0 tr. /2_„--7-4 ‘ ``-� 2 -3 _09 17. Transferred to: (Express as a negative #) Commissioner Date 0 18. Remarks: I hereby certify tha e fore' oing is true a • • -ct to the best of my knowledge. Note: Al! volumes must be corrected / PA Signatu a , . Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date November 12, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare Waterflood oxygen stopping tower gas and gas surges from Continuing operational efforts to minimize 10/1/08 12 00 AM 10/31/08 12 00 AM 293 Y Y well "heading" (gas lift operations) Operational Safety flare volumes Flare meter has been installed STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. November -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected 0 "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9. Flared or vented more than 1 hour (see Instr.) 711 10. Pilot and Purge 1500 11. Used for lease operations (specify in Remarks) 4591 12. Other (see instructions) Official Use Only 0 Authorization >1 hr: MCF Safety 7 // 13. TOTAL VOLUME (ITEMS 6 -12) 6801 MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 27738 Waste: MCF 16. Transferred from: 0 Commissioner Date 17. Transferred to: (Express as a negative #) 0 18. Remarks: I hereby certify t e fore.!oing is tru. and corr:- t to the best of my knowledge. Note: All volumes must be corrected signs re / 1 J� -C/ / Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name D. Denise Mohar Phone (432) 620 -4314 Date December 12, 2008 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate 4 ' - Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare: Watertlood oxygen stripping tower gas and gas surges from Continuing operational efforts to minimize 11/1/08 12:00 AM 11/30/08 12:00 AM 711 Y Y well "heading" (gas lift operations). Operational Safety Flare volumes. Flare meter has been installed. 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 3. Field 4. Operator 5. Month/Year of Disposition 1330000016 MGS C Platform Middle Ground Shoal XTO Energy, Inc. December -08 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of - Total Volume. 6. Sold Q Pool Name Pool Code Percent "A" Pool 524110 0 7. Reinjected Q "B ", "C ", & "D" Pool 524112 0 "E ", "F ", & "G" Pool 524114 100 8. Flared or vented 1 hour or less 0 9, Flared or vented more than 1 hour (see instr.) 679 10. Pilot and Purge 1550 11. Used for lease operations (specify in Remarks) 5170 Official Use Only 12. Other (see instructions) 0 Authorization >1 hr: 6 MC��i Safety 13. TOTAL VOLUME (ITEMS 6 -12) 7398 MCF Lease Use 14. NGL Gas Equivalent 0 MCF Conservation 15. Purchased gas 30549 Waste: MCF 16. Transferred from: 0 Lam/ Z -3 Commissioner Date 17. Transferred to: (Express as a negative #) 0 • 18. Remarks: I hereby certi hat the foreg g is true , nd corre.. o the best of my knowledge. Note: All volumes must be corrected Signat re Aj % / - Title Producton Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name b. Denise Mohar Phone (432) 620 -4314 Date January 13, 2009 AAC25.235. Form 10 -422 Rev. 4/2004 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Excess Flare Log Report Facility Name: Platform C Date & Time Event Gas Over Corrective Steps Taken to Begin End MCF Planned? 1 Hour Description of Incident Category Reason Actions Taken Minimize Recurrence Safety flare. Waterflood oxygen stopping tower gas and gas surges from Continuing operational efforts to mintm¢e _ 12/1/08 12:00 AM 12/31/08 12.00 AM 679 Y Y well "heading" (gas lift operations). Operational Safety flare volumes Flare meter has been installed