Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutRS Kustatan Gas DispositionState of Alaska AOGCC Gas Disposition Files Year: 2014 Facility: RS Kustatan Operator: COOK INLET ENERGY, LLC STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Ener , LLC 5. Month/Year of Disposition Jan -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 17,841 Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 1,008 9. Flared or vented more than 1 hour (see instr.) 14,355 10. Pilot and Purge 109 11. Assist Gas 12. Fuel gas used in lease operations. 29,862 13. Other (see instructions) Oficial Use Only Authorization hr Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 63,175 Lease Use MCF 15. NGL Gas Equivalent Conservation /L I ��� - j MCF 16. Purchased gas 393 Waste: 17. Transferred from: / / """ter ' "— S 6 — S� ��,,,,�.,...,.... Date 18. Transferred to: (Express as a negative #) 19. Remarks: Transferred gas: (16,243 mcf of gas to generate power for WRMU usage & 1,598 mcf sold to Chugach Electric Association) I hereby certify that the foregoing is truerd correct to the best of my knowledge. L,7 Signature �/i Title Production Manager Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Shawn Dillon Phone 334-6745 Date Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Cook Inlet Energy_ Excess Flare Log Facility Name Kustatan Production Facility Use Military form for time logs Jan -14 Date & Time Event Gas Steps Taken to Be in End MSCF Planned Description of Incident Cateaory Reason Actions Taken Minimize Recurrence Equipment 1-1-14 1-1-14 Flaring gas that can't be Begin selling in Separator B Separator 00:01 23:59 463 No used in order to Excess gas. None blowdown RU -3. excess 9 & 1-2-14 1-2-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 439 No used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-3-14 1-3-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 467 No used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-4-14 1-4-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 525 No used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-5-14 1-5-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 511 No used in order to Excess gas. None blowdown RU -3. gas as & V-168. 1-6-14 1-6-14 Flaring gas that can't be Begin selling Separator B Separator 00:01 23:59 515 No used in order to Excess gas. None blowdown RU -3. excess gas & 1-7-14 1-7-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 578 No used in order to Excess gas. None excess & V-168. blowdown RU -3. gas 1-8-14 1-8-14 Flaring gas that can't be Begin selling Separator Separator B 00:01 23:59 396 No used in order to Excess gas. None excess & blowdown RU -3. gas 1-9-14 1-9-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 470 No used in order to Excess gas. None excess & V-168. blowdown RU -3. gas 1-10-14 1-10-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 422 No used in order to Excess gas. None excess & V-168. blowdown RU -3. gas Flare_Log.xls Page 1 Date & Time Event Gas Steps Taken to Begin End MSCF Planned Desch [ion of Incident Cateaory Reason Actions Taken Minimize Recurrence E ui ment 1-11-14 1-11-14 Flaring gas that can't be 00:01 23:59 496 No used in order to Excess gas. None Begin selling Separator B blowdown RU -3. excess gas & V-168. 1-12-14 1-12-14 Flaring gas that can't be 00:01 23:59 341 No used in order to Excess gas. None Begin selling Separator B blowdown RU -3. excess gas & V-168. 1-13-14 1-13-14 Flaring gas that can't be 00:01 23:59 377 No used in order to Excess gas. None Begin selling Separator B blowdown RU -3. excess gas & V-168. 1-14-14 1-14-14 Flaring gas that can't be 00:01 23:59 404 No used in order to Excess gas. None Begin selling g 9 Separator B blowdown RU -3. excess gas & V-168. 1-15-14 1-15-14 Flaring gas that can't be 00:01 23:59 410 No used in order to Excess gas. None Begin selling Separator B blowdown RU -3. excess gas & V-168. 1-16-14 1-16-14 Flaring gas that can't be 00:01 23:59 434 No used in order to Excess gas. None Begin selling Separator B blowdown RU -3. excess gas & V-168. 1-17-14 1-17-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 549 No used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-18-14 1-18-14 381 No Flaring gas that can't be in Begin selling Separator Separator B 00:01 23:59 used in order to Excess gas. None blowdown RU -3. excess 9 & 1-19-14 1-19-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 316 No used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-20-14 1-20-14 347 No Flaring gas that can't be Begin selling Separator B 00:01 23:59 used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-21-14 1-21-14 Flaring gas that can't be in Begin selling Separator Separator B 00:01 23:59 474 No used in order to Excess gas. None blowdown RU -3. excess 9 & 1-22-14 1-22-14 Flaring gas that can't be Begin selling Separator B9 00:01 23:59 534 No used in order to Excess gas. None blowdown RU -3. excess as & V-168. 1-23-14 1-23-14 Flaring gas that can't be Begin selling Separator B arator 00:01 23:59 478 No used in order to Excess gas. None blowdown RU -3. excess gas & Flare_Log.xls Page 2 Date & Time Event Gas Steps Taken to Begin End MSCF Planned Description of Incident Cateaory Reason Actions Taken Minimize Recurrence E ui ment 1-24-14 1-24-14 Flaring gas that can't be 00:01 23:59 475 No used in order to Excess gas. None Begin selling 9 9 Separator B blowdown RU -3. excess gas & V-168. 1-25-14 1-25-14 Flaring gas that can't be 00:01 23:59 493 No used in order to Excess gas. None Begin selling Separator B blowdown RU -3. excess gas & V-168. 1-26-14 1-26-14 Flaring gas that can't be 00:01 23:59 463 No used in order to Excess gas. None Begin selling Separator B blowdown RU -3. excess gas & V-168. 1-27-14 1-27-14 Flaring gas that can't be 00:01 23:59 485 No used in order to Excess gas. None Begin selling in Separator Separator B blowdown RU -3. excess 9 & 1-28-14 1-28-14 593 No Flaring gas that can't be Begin selling Separator B 00:01 23:59 used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-29-14 1-29-14 Flaring gas that can't be Begin selling in Separator Separator B 00:01 23:59 524 No used in order to Excess gas. None blowdown RU -3. excess 9 & 1-30-14 1-30-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 524 No used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 1-31-14 1-31-14 Flaring gas that can't be Begin selling Separator B 00:01 23:59 471 No used order to Excess gas. None blowdown RU -3. excess gas & V-168. Flare Total for Month 1 14,355 Flare_Log.xls Page 3 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition I Feb -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 26,623 Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 1007% 8. Flared or vented 1 hour or less 909 9. Flared or vented more than 1 hour (see instr.) 5 3 3 ) 9 10. Pilot and Purge 99 11. Assist Gas 12. Fuel gas used in lease operations. 41,364 13. Other (see instructions) = Authorization >1 hr: Safety MCF i 14. TOTAL VOLUME (ITEMS 6.13) 75,694 Lease Use MCF 15. NGL Gas Equivalent Conservation � 3 2 � i MCF 16. Purchased gas Waste: MCF 17. Transferred from: , / L^ Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: Transferred gas: (23,308 mcf of gas to generate power for W RMU usage & 3,315 mcf sold to Chugach Electric Association) I hereby certify that the foregoing is t nd correct to the best of my knowledge. Signature �;;o Title Production Manager Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 I AAC25.235. Printed Name Shawn Dillon Phone 334-6745 Date Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate VrL Cook Inlet Energy_ Excess Flare Log Facility Name Kustatan Production Facility Use Military form for time logs Feb -14 Date & Time Event Gas Steps Taken to —Begin End MSCF Planned Description of Incident Category Reason Actions Taken Minimize RecurrenceE ui ment 2-1-14 2-1-14 Flaring gas that can't Begin selling Separator 471 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-2-14 2-2-14 Flaring gas that can't Begin selling Separator B 499 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-3-14 2-3-14 Flaring gas that can't Begin selling Separator B 432 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-4-14 2-4-14 Flaring gas that can't Begin selling Separator B 45 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-5-14 2-5-14 Flaring gas that can't Begin selling Separator B 419 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-6-14 2-6-14 Flaring gas that can't Begin selling Separator B 39 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-7-14 2-7-14 Flaring gas that can't Begin selling Separator B 286 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-8-14 2-8-14 Flaring gas that can't Begin selling Separator B 403 No be used order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-9-14 2-9-14 Flaring gas that can't Begin selling Separator B Separator 249 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & 2-10-14 2-10-14 Flaring gas that can't Begin selling arator Separator B 352 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & Flare_Log.xls Page 1 Date & Time Event Gas Steps Taken to BeginEnd MSCF Planned Description of Incident Category Reason Actions Taken Minimize Recurrence E ui ment 2-11-14 2-11-14 Flaring gas that can't Begin selling Separator B Separator 00:01 23:59 334 No be used in order to Excess gas. None blowdown RU -3. excess gas & 2-12-14 2-12-14 Flaring gas that can't Begin Selling Separator Separator B 286 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & 2-13-14 2-13-14 Flaring gas that can't Begin selling Separator Separator B 282 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas $ 2-14-14 2-14-14 Flaring gas that can't Begin selling Separator B 00:01 23:59 178 No be used in order to Excess gas. None & V-168. blowdown RU -3. excess gas 2-15-14 2-15-14 Flaring gas that can't Begin selling Separator B 00:01 23:59 34 No be used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 2-16-14 2-16-14 Flaring gas that can't Begin selling Separator B 31 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-17-14 2-17-14 Flaring gas that can't Begin selling Separator B 00:01 23:59 307 No be used in order to Excess gas. None blowdown RU -3. excess gas & V-168. 2-18-14 2-18-14 Flaring gas that can't Begin selling Separator B 297 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-19-14 2-19-14 Flaring gas that can't Begin selling Separator B 198 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-20-14 2-20-14 Flaring gas that can't Begin selling Separator Separator B 97 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & 2-21-14 2-21-14 Flaring gas that can't Begin selling Separator B 15 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-22-14 2-22-14 Flaring gas that can't Begin selling Separator B 23 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. 2-23-14 2-23-14 Flaring gas that can't Begin selling Separator B 17 No be used in order to Excess gas. None 00:01 23:59 blowdown RU -3. excess gas & V-168. Flare_Log.xls Page 2 Date & Time Event Gas Steps Taken to Be in End MSCF Planned Descri tion of Incident Cale o Reason Actions Taken Minimize Recurrence Equipment 2-24-14 2-24-14 Flaring gas that can't Begin selling Separator B Separator 00:01 23:59 12 No be used in order to Excess gas. None blowdown RU -3. excess gas & 2-25-14 2-25-14 Flaring gas that can't Begin selling in Separator SeparatorB 00:01 23:59 4 No be used in order to Excess gas. None blowdown RU -3. excess 9 & 2-26-14 2-26-14 Flaring gas that can't Begin selling in g Separator SeparatorB 00:01 23:59 5 No be used in order to Excess gas. None blowdown RU -3. excess g 8 2-27-14 2-27-14 Flaring gas that can't Begin selling Separator Separator B 00:01 23:59 13 No be used in order to Excess gas. None blowdown RU -3. excess gas $ 2-28-14 2-28-14 Flaring gas that can't Begin selling in g SeparatorB Separator 00:01 23:59 3 No be used in order to Excess gas. None blowdown RU -3. excess 9 & Flare Total for Month Flare_Log.xls Page 3 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISMSITION 1. Facility Number 1330000039 2. Facility Name Kustatan Field 3. Field Kustatan Field 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition I Mar -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume, 6. Sold _ Pool Name Pool Code Percent 7. Reinjected Tyonek Formation 494500 100 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 11. Assist Gas 12. Fuel gas used in lease operations. 13. Other (see instructions) Authorization>1 hr: Official Use Only Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) _ Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoi is true and correct to the best of my knowledge. / Note: All volumes must be corrected Signature N D Title Production Manager to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Shawn Dillon Phone 334-6745 Date 91-o-1301 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Energy, LLC 5. Month/Year of Disposition r-14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 22,929 Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 959 9. Flared or vented more than 1 hour (see instr.) 391 10. Pilot and Purge 106 11. Assist Gas 12. Fuel gas used in lease operations. 26,834 13. Other (see instructions) Official Use Only Authorization>1 hr: Safety 3-7 MCF 14. TOTAL VOLUME (ITEMS 6.13) 51,219 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 7,911 18. Transferred to: (Express as a negative #) Commissioner Date 19. Remarks: Transferred gas: (21,654 mcf of gas to generate power for W RMU usage & 1,275 mcf sold to Chugach Electric Association) I hereby certify that the foregoing is true a d correct to the best of my knowledge. / Note: All volumes must be corrected Signature Title Production Manager to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Shawn Dillon Phone 334-6745 Date f -/r/ AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Cook Inlet Energy_ Excess Flare Log Facility Name Kustatan Production Facility Use Military form for time logs Apr -14 Date & Time Be in End Event Gas MCF Planned Description of Incident Category Reason Actions Taken Steps Taken to Minimize Recurrence E ui ment 4-3-14 09:45 4-3-14 17:30 147 Yes C-1228 shut -down for an oil change. PQM's werec-1226 getting worked on. shutdown for maintenance.C-1228 Maintained control & Planned. 4-19-14 08:40 4-19-14 09:40 244 No Gen A shutdown Flame out shutdown for mainenance Solar rep coming out to field C 1228 Flare Total for Month 391 Flare_Log.xls Page 1 1=r' STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Energy, LLC 5. Month/Year of Disposition Ma 14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 16,895 Pool Name Pool Cade Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 956 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 109 11. Assist Gas 12. Fuel gas used in lease operations. 39,740 13. Other (see instructions) o _. Authorization >t hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 57,700 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 10,285 18. Transferred to: (Express as a negative #) Commissioner Date 19. Remarks: Transferred gas: (15,395 mcf of gas to generate power for W RMU usage & 1,500 mcf to power Rig #191) NOTE: No flow of gas from east side of Cook Inlet to west side. I hereby certify that the foregoing is true and correct to the best of my knowledge. %I Signature y/ Title Production Manager Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. / Printed Name Shawn Dillon Phone 334-6745 Date t "�g �y Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition I Jun -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 7,615 Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 322 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 106 11. Assist Gas 12. Fuel gas used in lease operations. 15,124 13. Other (see instructions) Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 23,167 Lease Use MCF 15, NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 8,672 18. Transferred to: (Express as a negative #) Commissioner Date 19. Remarks: Transferred gas: (6,115 mcf of gas to generate power for W RMU usage & 1,500 mcf to power Rig #191) NOTE: No flow of gas from east side of Cook Inlet to west side. I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Title Production Manager Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Shawn Dillon Phone 334-6745 Date 7-1-y-ly Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Energy, LLC 5. Monlh/Year of Disposition Jul -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 255 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 109 11. Assist Gas 12. Fuel gas used in lease operations. 14,612 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6.13) 14,976 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas 38,334 Waste: MCF 17. Transferred from: West Foreland 4,371 18. Transferred to: (Express as a negative #) Commissioner Date 19. Remarks: NOTE: Flow of gas from east side of Cook Inlet to west side. I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature "'� Title Chief Executive Officer Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. n p Printed Name David Hall Phone 334-6745 Date tj' U o�0��/ Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODIMM ro-q n1SpnQ1T1nK1 RECEIVED SEP 2 3 2014 1. Facility Number2. Facility Name 1330000039 Kustatan Field Disposition 3. Field Kustatan Field Volume MCF 4. Operator 5. Month/Year of Disposition Cook Inlet Energy, LLC Aug -14 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold _ Pool Name Pool Code Percent 7. Reinjected Tyonek Formation 494500 100 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 11. Assist Gas 12. Fuel gas used in lease operations. 13. Other (see instructions) Safety Authorization >1 hr: MCF 14. TOTAL VOLUME (ITEMS 6-13) _ Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is U_ •_tr a and correct to the best of my knowledge. Note: All volumes must be corrected Signature / Title Production Manager to pressure of 14.65 psia and to a Q L 9 IU temperature of 60o F. Authority 20 Printed Name David Kumar Phone 334-6745 Date J S _I AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION RECE►v cW OCT 16 20% ,a.OGCG 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Energy, LLC 5. MonthfYear of Disposition I Sep -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 255 9. Flared or vented more than 1 hour (see instr.) 119 10. Pilot and Purge 106 11. Assist Gas 12. Fuel gas used in lease operations. 6,970 13. Other (see instructions) Authorization >1 h r. Safety / p MCF 14. TOTAL VOLUME (ITEMS 6-13) 7,450 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas 28,167 Waste: MCF 17. Transferred from: West Foreland 6,075 11-116-1 18. Transferred to: (Express as a negative #) Z Commissioner Date 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature Title Production Manager to pressure of 14.65 Asia and to a f temperature of 60o F. Authority 20 Printed Name David Kumar Phone 334-6745 Date Ld I I AAC25.235. Forth 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate VL f61z4/[9- Facility Name Kustatan Production Facility Cook inlet Energy_ Excess Flare Log Use Military form for time logs RhUr v &.W OCT 16 20A AOGCC Sep -14 Date & Time Begin End Event Gas MSCF Planned I Description of Incident Category Reason Actions Taken Steps Taken to Minimize Recurrence E ui ment 9/11/14 14:10 9/11/14 21:40 71 No compressor shutdown 1st stage scrubber hi level replaced PSV, replaced pump N/A C -122B 9/17/14 14:00 9/17/14 20:45 48 Yes compressor shutdown P-121 B leaking gas replaced P -121B N/A C -122B Flare Total for Month 1 119 Flare_LogAs Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION HECEIVED NOV 2 0 2014 AOGCC 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Intel Energy, LLC 5. MonthNear of Disposition I Oct -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold - Pool Name Pool Code Percent T. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less .� 63 9. Flared or vented more than 1 hour (see instr.) 475 10. Pilot and Purge 109 11. Assist Gas 12. Fuel gas used in lease operations. 6,845 13. Other (see instructions) Official Use Only Authorization >t hr: Safety ? � J MCF 14. TOTAL VOLUME (ITEMS 6-13) 7,492 Lease Use MCF 15, NGL Gas Equivalent Conservation MCF 16. Purchased gas 18,498 Waste: MCF 17. Transferred from: West Foreland 5,723 18. Transferred to: (Express as a negative #) Commissioner Date 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature Title Production Manager I to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name visN umar Phone 334-6745 Date AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate y7L Cook Inlet Energy_ Excess Flare Log Facility Name Kustatan Production Facility Use Military form for time logs Oct -14 RCINIVED NOV 10 �P.t4 Date & Time Begin End 10/3/14 10/3/14 10:10 11:55 Event Gas MSCF 24 Planned Yes Description of Incident Replace scrubber drain pump Category Reason Pump wore out Actions Taken Steps Taken to Minimize Recurrence Equipment epace replaced pump N/A C-1 22b gas compressor 10/6/14 10:35 10/6/14 11:45 39 No Instrument valve changeout Bad valve Replaced valve N/A C-1 22b gas compressor Flare Total for Month 63 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition I Nov -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume, 6. Sold Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 656 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 106 11. Assist Gas 12. Fuel gas used in lease operations. 6,066 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 6,828 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas 22,080 yyaste: MCF 17. Transferred from: West Foreland 8,022 18. Transferred to: (Express as a negative #) Commissioner Date 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. ,✓�� Signature Title Production Manager Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name id Kumar Phone 334-6745 Date ! I b I Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION JAN 2 0 2015 1. Facility Number 1330000029 2. Facility Name Kustatan 3. Field Redoubt Unit 4. Operator I Cook Inlet Energy, LLC 5. Month/Year of Disposition I Dec -14 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected Redoubt Shoal 720100 100% 8. Flared or vented 1 hour or less 531 9. Flared or vented more than 1 hour (see instr.) 10. Pilot and Purge 109 11. Assist Gas 12. Fuel gas used in lease operations. 5,550 13. Other (see instructions) Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 6.190 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas 23,224 Waste: MCF 17. Transferred from: West Foreland 4,597 18. Transferred to: (Express as a negative #) Commissioner Date 19. Remarks: I hereby certify that the foregoing is tra and correct to the best of my knowledge. W�r'/`_/`• Note: All volumes must be corrected Signature ( • t - Title Production Manager to pressure of 14.65 psia and to a q temperature of 60o F. Authority 20 Printed Name David Kumar Phone 334-6745 Date 1 ( t I h AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate