Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutRS Kustatan Gas DispositionState of Alaska AOGCC
Gas Disposition Files
Year: 2013
Facility: RS Kustatan
Operator: COOK INLET ENERGY, LLC
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. MonthNear of Disposition
I Jan -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
5,668
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
636
9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
109
11. Assist Gas
12. Fuel gas used in lease operations.
965
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-13)
7,378
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
24,057
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Transferred gas: WF = 11,663 MCF (13,968 mcf of gas to generate power for W RMU usage & 18,365 mcf of gas for KPF usage 8,151 mcf of gas
prey usage)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
/f,� ,(/',
Signature �� (-"�'y Title Chief Executive Officer
Note: All volumes must be corrected
to pressure of 14.65 psis and to a
of 60o F. Authority 20
AAC25.235.
1temperature
Printed Nam(rDavid Hall Phone 334-6745 Date 02 1j io r 3
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. Month/Year of Disposition
I Feb -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
225
9. Flared or vented more than 1 hour (see instr.)
4,030
10. Pilot and Purge
99
11. Assist Gas
12. Fuel gas used in lease operations.
30,626
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-13)
34,980
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
/�
—! C30
MCF
16. Purchased gas
8,535
Waste:
MCF
17. Transferred from:
4--1-13
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Transferred gas: WF = 10,097 MCF (16,326 mcf of gas to generate power for W RMU usage & 16,445 mcf of gas for KPF usage 8,086 mcf of gas
Osprey usage)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature (/ ^tel �V _ Title Chief Executive Officer
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
AAC25.235.
Printed Nam avid Hall Phone 334-6745 Date �O/3
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
3;1>7f
Facility Name Kustatan Production Facility
COOK INLET ENERGY
Excess Flare Log
Use Military form for time logs
2/1/2013
Date & Time
Begin End
Event Gas I
MMSCF
Planned
Description or Incident
Category
Reason
Actions Taken
Steps Taken to
Minimize Recurrence
Equipment
2-9-13
0720
2-9-13
0830
36
No
Power outage
Unplanned
Power outage
Restarted after
getting power
back to the unk
N/A
C-1228 Gas
compressor
2-11-13
1525
2-11-13
2359
336
Yes
Well test Osprey gas
well RU#3
Planned
Well test
Flow to gas well
to flare
N/A
Osprey gas
well RU#3
2-12-13
0001
2-12-13
2359
1 600
Yes
Well test Osprey gas
well RU#3
Planned
Well test
Flow to gas well
to flare
N/A
Osprey gas
well RU#3
2-13-13
0001
2-13-13
2359
604
Yes
Well test Osprey gas
well RU#3
Planned
Well test
Flow to gas well
to flare
N/A
Osprey gas
well RU#3
2-14-13
1140
2-14-13
2359
850
Yes
Well step rate test
Osprey as well RU#3
Planned
Well test
Flow to gas well
to flare
N/A
Osprey gas
well RU#3
2-15-13
0001
2-15-13
2359
1 1495
Yes
Well step rate test
I Osprey gas well RU#3
Planned
Well test
Flow to gas well
to flare
N/A
Osprey gas
well RU#3
2-16-13
0001
2-16-13
0240
109
Yes
Well step rate test
Osprey gas well RU#3
Planned
Well test
Flow to gas well
to flare
N/A
Osprey gas
well RU#3
Flare Total for Month 4,030
Flare_Log.xls Page 1
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. Month/Year of Disposition
Rev Mar -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
22,296
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
251
9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
109
11. Assist Gas
12. Fuel gas used in lease operations.
21,013
13. Other (see Instructions)
Authorization >1 hr.
Safety
MCF
14. TOTAL VOLUME (ITEMS 6.13)
43,669
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
q1
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #) —
Commissioner - Date
19. Remarks: Transferred gas:
Osprey usage)
WF = 10,8 CF (18,719 mcf of gas to generate power for W RMU usage & 4,398 mcf of gas for KPF usage 16,975 mcf of gas
I hereby certify that the foregoint is t e and co ect to the best of my knowledge.
Note: All volumes must be corrected
Signature Title President to pressure of 14.65 psia and to a
/ temperature of 60o F. Authority 20
Printed Name Walter J. Wilcox Phone 3346745 Date "t 2."t '013 AAC25.235.
Form 10-422 Rev. 512009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. Month/Year of Disposition
I Apr -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
19,349
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
S. Flared or vented 1 hour or less
240
9. Flared or vented more than 1 hour (see instr.)
10. Pilot and Purge
106
11. Assist Gas
12. Fuel gas used in lease operations.
29,642
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-13)
49,337
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
78
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Transferred gas: WF = 10,378 MCF (17,777 mcf of gas to generate power for WRMU usage & 4,187 mcf of gas for KPF usage 25,801 mcf of gas
Osprey usage)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature Title Chief Executive Officer
Note: All volumes must be corrected
to pressure of 14.65 psis and to a
temperature of 60o F. Authority 20
AAC25.235.
Printed Na avid Hall Phone 334-6745 Date -S ZJ Z c 3
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. Month/Year of Disposition
I May -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
19,972
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
301
9. Flared or vented more than 1 hour (see instr.)
40
10. Pilot and Purge
109
11, Assist Gas
12. Fuel gas used in lease operations.
44,505
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
� (j
MCF
14. TOTAL VOLUME (ITEMS 6.13)
64,827
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Transferred gas: (16,621 mcf of gas to generate power for W RMU usage & 19,972 mcf of gas Osprey usage)
3,351 mcf sold to Chugach Electric Association
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Signature Title Chief Executive Officer
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
AAC25.235.
Printed N e David Hall Phone 334-6745 Date l-3
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Cook inlet Energy_
Excess Flare Log
Facility Name Kustatan Production Facility Use Military form for time logs 5/1/2013
Date & Time
Begin End
Event Gas
MMSCF
Planned
Description of Incident
Category
Reason
Actions Taken I
Steps Taken to
Minimize Recurrence
Equipment
5/1/13
12:15
Online
14:00
24
No
Power Outage
N/A
Started KPF back
up
N/A
C -122B gas
compressor
5-19-13
07:00
5-19-13
13:00
16
Yes
Install unloader valves,
maintenance
Maintenance/
performance
Performed
maintenance
needed
N/A
C -122B gas
compressor
5/20/13
15:50
Online
16:15
34
No
Power Outage
N/A
Started KPF back
up
N/A
C -122B gas
compressor
5/31/13
23:00
Online
24:00
17
No
Power Outage
N/A
Started KPF back
up
N/A
C -122B gas
compressor
Flare Total for Month 1 91
Flare_Log.xls Page 1
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Ener , LLC
5. Month/Year of Disposition
Rev JUN -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
32,990
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
229
9. Flared or vented more than 1 hour (see insk.)
34
10. Pilot and Purge
106
11. Assist Gas
12. Fuel gas used in lease operations.
48,184
13. Other (see Instructions)
Authorization >1 hr:
Safety
�
MCF
14. TOTAL VOLUME (ITEMS 6-13)
81,543
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
?/ 2 _ /
(Q JDate
18. Transferred to: (Express as a negative #)
Commissioner
19. Remarks: Transferred gas: (17,738 mct of gas to generate power for WRMU usage & 15,252 mcf sold to Chugach Electric Association)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
/Note:
Signature f Title Chief Executive Officer
All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
AAC25.235.
9�
Printed a David Hall Phone 334-6745 Date R "b 3
Form 10-422 Rev. 512009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Cook Inlet Energy_
Excess Flare Log
Facility Name Kustatan Production Facility Use Military form for time logs 6/1/2013
Date & Time
Begin End
Event Gas
MMSCF
I Planned I
Description of Incident
Category
Reason
Actions Taken
Steps Taken to
Minimize Recurrence
Equipment
6/09/13
23:00
6/09/13
00:00
34
No
2 Power Outages
N/A
Started KPF back
up
N/A
C-1228 gas
compressor
Flare Total for Month 1 34
Flare_Log.xls Page 1
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. MonthNear of Disposition
I Jul -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
28,804
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
232
9. Flared or vented more than 1 hour (see instr.)
171
10. Pilot and Purge
109
11. Assist Gas
12. Fuel gas used in lease operations.
45,949
13. Other (see instructions)
Official Use Only
Authorization>1 hr:
Safety
/
/ f �
MCF
14. TOTAL VOLUME (ITEMS 6.13)
75,265
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
r / —3—/
18. Transferred to: (Express as a negative #)
Commissioner D to
19. Remarks: Transferred gas: (12,771 mcf of gas to generate power for W RMU usage & 16,033 mcf sold to Chugach Electric Association)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
/
Signature�r ` / Title Chief Executive Officer
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
AAC25.235.
G
Printed Name Daviq Phone 334-6745 Date o /g
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Cook Inlet Energy_
Excess Flare Log
Facility Name Kustatan Production Facility Use Military form for time logs 7/1/2013
Date & Time
Begin End
Event Gas
MMSCF I
Planned I
Description of Incident
Category
Reason
Actions Taken I
Steps Taken to
Minimize Recurrence
Equipment
7-12-13
1410
7-12-13
1800
130
No
Gas compressor
cooler fan belt broke
Production
Equipment failure
Replaced belt
Annual inspection
C-1228 gas
compressor.
7-24-13
1250
7-24-13
1450
41
No
Gas compressor high
bearing vibration
Production
Equipment failure
Greased Bearings
Modified inspection
ports
C-1228 gas
compressor.
Flare Total for Month 1 171
Flare_Log.xls Page 1
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
S. Month/Vear of Disposition
I Aug -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
34,969
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
267
9. Flared or vented more than 1 hour (see instr.)
-
10. Pilot and Purge
109
11. Assist Gas
12. Fuel gas used in lease operations.
50,475
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-13)
85,820
Lease Use
MCF
15, NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Transferred gas: (13,101 mcf of gas to generate power for W RMU usage & 21,868 mcf sold to Chugach Electric Association)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
/L
Signature - Title Chief Executive Officer
Note: All volumes must be corrected
to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
AAC25.235.
/
Printed Name Davi all Phone 334-6745 Date ���(S ��
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. Monthfyear of Disposition
I Sep -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
30,539
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
43
9. Flared or vented more than 1 hour (see instr.)
-
10. Pilot and Purge
106
11, Assist Gas
12. Fuel gas used in lease operations.
44,054
13. Other (see instructions)
Official Use Only F
Authorization >1 hr:
Safety
� z
J
MCF
14. TOTAL VOLUME (ITEMS 6-13)
74,742
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:
MCF
17. Transferred from:
t
18. Transferred to: (Express as a negative #)
Commissioner Date
19. Remarks: Transferred gas: (1 2,568d of gas to generate power for WRMU usage R 17,971 mcf sold to Chugach Electric Association)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected
Signature ``J`Title Chief Executive Officer to pressure of 14.65 psia and to a
/ temperature of 60o F. Authority 20
Printed Name DZ id Hall Phone 334-6745 Date A9 /l �t/� ` 3 AAC25.235.
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Cook Inlet Energy_
Excess Flare Log
Facility Name Kustatan Production Facility Use Military form for time logs Sep -13
Date & Time
Begin End
Event Gas
MCF
Planned I
Description of Incident
Category
Reason
Actions Taken
Steps Taken to
Minimize Recurrence
Equipment
9/14/13
03.00
9/14/13
2400
43
No
Power Outage
N/A
Started KPF back
up
N/A
C -122B gas
compressor
Flare Total for Month 1 43 1 Flare_Log.xls Page 1
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Ener ,LLC
5. Month/Vear of Disposition
01
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
25,582
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
1,105
9. Flared or vented more than 1 hour (see instr.)
163
10. Pilot and Purge
109
11. Assist Gas
12. Fuel gas used in lease operations.
48,779
13. Other (see instructions)
Official Use Only
Authorization >1 hr:
Safety
i
MCF
i
14. TOTAL VOLUME (ITEMS 6-13)
75,738
Lease Use
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste:'' // MCF
/ / * — (`-�,
Commissioner Jane
17. Transferred from:
18. Transferred to: (Express as a negative #)
19. Remarks: Transferred gas: (12,793mcf of gas to generate power for WRMU usage & 12,789 mcf sold to Chugach Electric Association)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected
Signature `-" Title Chief Executive Officer to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
Printed Na David Hall Phone 334-6745 Date/,OpA,,-,AAC25.235.
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
i/77-
3llglg-
Facility Name Kustatan Production Facility
Cook Inlet Energy_
Excess Flare Log
Use Military form for time logs
Oct -13
Date & Time
Begin End
Event Gas
I MSCF
I Planned
Description of Incident
Category
Reason
Actions Taken
Steps Taken to
Minimize Recurrence
E ui ment
10-14-13,
13:15
10-14-13,
15:15
56
no
Water Inj. Shutdown
High gas
pressure
Osprey piping
repairs
Re -started
none
P-1 45A
10-31-13
01:10
10-31-13
03:05
107
no
Lube oil timer failed
High gas
pressure
Equipment failure
Replaced lube oil
timer
None, have spare
timer on hand for
future use.
C-1226 gas
compressor
p
Flare Total for Month 1 163
Flare_Log.xls Page 1
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
Cook Inlet Energy, LLC
5. Month/Year of Disposition
I Nov -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
18,661
Pool Name PoolCode Percent
7. Reinjected
Redoubt Shoal 720100 1007%
8. Flared or vented 1 hour or less
3,160
9. Flared or vented more than 1 hour (see instr.)
519
10. Pilot and Purge
106
11. Assist Gas
12. Fuel gas used in lease operations.
43,718
13. Other (see instructions)
01'"al U3e 01*
Authorization >t hr:
Safety
MCF
14. TOTAL VOLUME (ITEMS 6.13)
66,164
Lease Use
MCF
15. NGL Gas Equivalent
Conservation
MCF
16. Purchased gas
Waste����`' J MCF
I Comtemmisssiiunn"e"rr Date
17. Transferred from:
18. Transferred to: (Express as a negative #)
19. Remarks: Transferred gas: (13,970 mcf of gas to generate power for W RMU usage & 4,691 mcf sold to Chugach Electric Association)
I hereby certify that the foregoing is true and correct to the best of my knowledge.
Note: All volumes must be corrected
Signature /M Title Chief Executive Officer to pressure of 14.65 psia and to a
temperature of 60o F. Authority 20
Printed Name David/,Il Phone 334-6745 Date */14/3 AAC25.235.
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
3%19 %5
Cook Inlet Energy_
Excess Flare Log
Facility Name Kustatan Production Facility Use Military form for time logs Nov -13
Date & Time
Begin End
Event Gas
MCF
Planned
Description of Incident
Category
Reason
Actions Taken
steps Taken to
Minimize Recurrence
E ui ment
11-25-13
07:00
11-25-13
23:59
132
Yes
Flaring gas that can't
be used in order to
swab RU -3.
Excess gas.
Gas line allowable
pressure @ its
maximum.
Separator B &
V-168.
11
000:0:013 1
11
233:59:59
387
Yes
Flaring gas that can't
be used in order to
swab RU -3.
Excess gas.
Gas line allowable
pressure @ its
maximum.
Separator B &
V-168.
Flare Total for Month 1 519
Flare_Log.xls Page 1
STATE OF ALASKA
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
1. Facility Number
1330000029
2. Facility Name
Kustatan
3. Field
Redoubt Unit
4. Operator
I Cook Inlet Energy, LLC
5. MonthNear of Disposition
I Dec -13
Disposition
Volume MCF
20. For production from multiple pools, list contribution of each pool as a percent of
Total Volume.
6. Sold
16,627
Pool Name Pool Code Percent
7. Reinjected
Redoubt Shoal 720100 100%
8. Flared or vented 1 hour or less
4
9. Flared or vented more than 1 hour (see matt.)
10. Pilot and Purge
109
11. Assist Gas
12. Fuel gas used in lease operations.
38,310
13. Other (see instructions)
Authorization >1 hr:
- cial Use Only
Safety
MCF
14. TOTAL VOLUME (ITEMS 6-13)
60,522
Lease Use
MCF
15. NGL Gas Equivalent
Conservation -4 2
✓
MCF
16. Purchased gas
2.596
Wa,,,s���tteryry�:
MCF
17. Transferred from:
/ '� T
Commm'i�sssio+ner uate
18. Transferred to: (Express as a negative #)
19. Remarks: Transferred gas: (16,627 mcf of gas to generate power for WRMU usage & -0- mcf sold to Chugach Electric Association)
I hereby certifyXthithe oin true and correct to the best of my knowledge. f� Note:All volumes must be corrected
Signatur ✓ a c- // Title Chief Executive Officer f0 pressure of 14.65 Sla and t0 a
temperature of 60o F. Authority 20
Printed Name David Hall Phone 334-6745 Date O - AAC25.235.
Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate
Cook Inlet Energy_
Excess Flare Log
Facility Name Kustatan Production Facility Use Military form for time logs Dec -13
Date & Time
Event Gas
Steps Taken to
Begin End I
MSCF I
Planned
Description of Incident
Category
Reason
Actions Taken
Minimize Recurrence
E ui ment
11-30-13
12-01-13
Flaring gas that can't
Begin selling
Separator B &
350
No
be used in order to
Excess gas.
None
13:00
23:59
swab RU -3.
excess gas
V-168.
12-02-13
12-02-13
Flaring gas that can't
Begin selling
Separator B &
282
No
be used in order to
Excess gas.
None
00:01
23:59
unload RU -3.
excess gas
V-168.
12-03-13
12-03-13
Flaring gas that can't
Begin selling
Separator B &
185
No
be used in order to
Excess gas.
None
00:01
23:59
unload RU -3.
excess gas
V-168.
12-04-13
12-04-13
Flaring gas that can't
Begin selling
Separator B &
136
No
be used in order to
Excess gas.
None
00:01
23:59
unload RU -3.
excess gas
V-168.
12 -OS -13
12-05-13
Flaring gas that can't
Begin selling
Separator B &
77
No
be used in order to
Excess gas.
None
00:01
23:59
unload RU -3.
excess gas
V-168.
12-06-13
12-06-13
Flaring gas that can't
Begin selling
Separator B &
70
No
be used in order to
Excess gas.
None
00:01
23:59
unload RU -3.
excess gas
V-168.
12-07-13
12-07-13
Flaring gas that can't
Begin selling
Separator B &
111
No
be used in order to
Excess gas.
None
00:01
23:59
swab RU -3.
excess gas
V-168.
12-08-13
12-08-13
Flaring gas that can't
Begin selling
Separator B &
52
No
be used in order to
Excess gas.
None
00:01
23:59
unload RU -3.
excess gas
V-168.
12-09-13
12-09-13
Flaring gas that can't
Begin selling
Separator B &
32
No
be used in order to
Excess gas.
None
00:01
23:59
unload RU -3.
excess gas
V-168.
12-10-13
12-10-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
57
No
be used in order to
Excess gas.
None
excess gas
V-168.
unload RU -3.
12-11-11
12-11-13
12-11-13Flaring
12-11-13
gas that can't
Begin selling
Separator B &
00:01
23:59
27
No
be used in order to
Excess gas.
None
excess gas
V-168.
unload RU -3.
Flare_Log.xls Page 1
Date & Time
ent G
Event Gas
Steps Taken to
Begin End
Planned
Description of Incident
Category
Reason
Actions Taken
Minimize Recurrence
Equipment
12-12-13
12-12-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
10
No
be used in order to
Excess gas.
None
unload RU-3.
excess gas
Vrator
12-13-13
12-13-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
3
No
be used in order to
Excess gas.
None
excess
V-168.
unload RU-3.
gas
12-15-13
12-15-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
1
No
be used in order to
Excess gas.
None
Vrator
unload RU-3.
excess gas
12-16-13
12-16-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
2
No
be used in order to
Excess gas.
None
V-168.
unload RU-3.
excess gas
12-17-13
12-17-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
4
No
be used order to
Excess gas.
None
excess
V-168.
unload RU-3.
gas
12-18-13
12-18-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
4
No
be used in order to
Excess gas.
None
excess
V-168.
unload RU-3.
gas
12-23-13
12-23-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
46
No
be used in order to
Excess gas.
None
excess
V-168.
unload RU-3.
gas
12-24-13
12-24-13
Flar
Flaring gas a
't t thcan
Begin selling
Separator B &
00:01
23:59
285
No
be used in order to
Excess gas.
None
excess gas
V-168.
-
unload RU-3.
12-25-13
12-25-13
12-25-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
414
No
be used in order to
Excess gas.
None
excess
Vrator
unload RU-3.
gas
12-26-13
12-26-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
349
No
be used order
Excess gas.
None
excess gas
V-168.
unload RU-3.
12-27-13
12-27-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
402
No
be used in order to
Excess gas.
None
excess gas
V-168.
swab RU-3.
12-28-13
12-28-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
456
No
be used in order to
Excess gas.
None
excess gas
V-168.
swab RU-3,
12-29-13
12-29-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
373
No
be used in order to
Excess gas.
None
excess gas
V-168.
swab
12-30-13
12-30-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
352
No
be used in order to
Excess gas.
None
excess gas
V-168.
swab RU-3-
12-31-13
12-31-13
Flaring gas that can't
Begin selling
Separator B &
00:01
23:59
383
No
be used in order to
Excess gas.
None
excess gas
V-168.
swabRU-3.
Flare_Log.xls Page 2
Flare Total for Month 4,463
Flare_Log.xls
Page 3