Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutSR Swanson River Storage - Hilcorp Alaska, LLCState of Alaska AOGCC Gas Disposition Files Year: 2017 Facility: SR Swanson River Storage Operator: Hilcorp Alaska LLC     STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION CORRECTED Warn ITV DCDnDT ne oennuren ref. mm�n�m,r�u 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field 4.Operator Swanson River Unit NILCORP ALASKA LLC 5. MonthNear of Disposition I January 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 137,601 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 83,185 8. Flared or vented 1 hour or less 80 9. Flared or vented more than 1 hour (see instr.) .650 SWANSON RIVER, GAS STORAGE 772803 4.79% SWANSON RIVER, GAS STORAGE 772805 95.21% 10. Pilot and Purge 402 11. Assist Gas 0 12. Fuel gas used in lease operations 19,904 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13). Includes Transferred 241,822 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas -Transferred from SRF 0 Waste: MCF 17. Transferred from: (ON -lease Gas) 0 18. Transferred to: (92,546) Commissioner Date 19. Remarks: Transferred From: Swanson River Field 73,447 Injected into Storage 118,456 Other 15708 9,738 Transferred Gas used as Fuel: - 83,185 1 8. 9.10. 12. Other 1570B (Acq Gas for Lease Uses) 4,551 Storage Inv. 3,722,205 vGrlo i,� . Transferred To: Swanson River Field (Hemlock) for Injection 92,546 I hereby certify that the foregoing is true �and `correct to the best of my knowledge. Signature c.,mwsey .�1rt� Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Cortne Der Phone 713-289-2881 Date 3/29/2017 AAC25.235. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACII ITV RFPnRT ng PDnn11CFn l AQ nrSRnQlTrnu 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field 4.Operator Swanson River Unit HILCORP ALASKA LLC 5. Month/Year of Disposition 1January2017 Disposition Volume MCF 20. Forpmduction from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 45,055 Pool Name Pool Code Percent 7. Reinjected` Includes Transferred Gas. See Remarks 83,185 8. Flared or vented 1 hour or less 80 9. Flared or vented more than 1 hour (see instr.) 1650 SWANSON RIVER, GAS STORAGE 772803 4.80% SWANSON RIVER, GAS STORAGE 772805 95.20% 10. . Pilot and Purge 402 11. Assist Gas 0 12. Fuel gas used in lease operations 19,904 13. 14. Other (see instructions) INA on 9% W-00 �- O T n g Official Use Only Authorization>1 hr: Safety �5' MCF 149,276 Lease Use MCF 15. AJWiAlentImMoir'""- 0 Conservation MCF 16. Purchased gas -Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 3 18. Transferred to: (92,546) 'Commissioner Date 19. Remarks: Transferred From: Swanson River Field Other 15708 8.9.10.12. Other 1570B (Acq Gas for Lease Uses) Transferred To: Swenson River Field(Hemlock) for Injection 73,447 9,738 83,185 4,551 92,546 Injected into Storage 118,456 Transferred Gas used as Fuel: - Storage Inv. 3,722,205 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature �,tti7'��.��.�t Printed Name Cortne Der Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 pale and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Dale 2/16/2017 {rTv, 3/z 1) 17., SWANSON RIVER STORAGE Janua -17 TOW I1 HR: 650.0 EXCESS VENTING DUE TO 01/01/2017 124250 1330000081 1/4/2017 19:00'00 13000 1/5/2017 U 6.2 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL CAUSED BY A FROZEN PRESSURE COMPRESSOR CAN BE RESTARTED. DRAIN. EXCESS VENTING DUE TO 01/01/2017 124250 1330000081 1/4/2017 19:00:00 1:30:00 1/5/2017 U 1.8 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL CAUSED BY FROZEN PRESSURE COMPRESSOR CAN BE RESTARTED. DRAIN. UPDATED DESCRIPTION: EXCESS VENTING DUE TO SHUTDOWN OF VRU COMPRESSOR CAUSED BY 01/01/2017 124250 1330000081 1/11/2017 15:00:00 22:00:00 1/11/2017 U 8.5 MULTIPLE MALFUNCTIONS EXCESS VENTING NECESSARY UNTIL INCLUDING WATER PUMP COMPRESSOR CAN BE RESTARTED. CAVRATING AND HIGH PRESSURE SUCTION FROM A FREEZING COOLING SKID. EXCESS VENTING DUE TO 01/01/2017 124250 1330000081 1/19/2017 22:00:00 2:00:00 1/20/2017 U 2.5 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL CAUSED BY A FROZEN PRESSURE COMPRESSOR CAN BE RESTARTED. DRAIN. EXCESS VENTING DUE TO 01/012017 124250 1330000081 1/19/2017 22:00:00 2:00:00 1/20/2017 U 25 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL CAUSED BY A FROZEN PRESSURE COMPRESSOR CAN BE RESTARTED. DRAIN. EXCESS VENTING DUE TO 01/012017 124250 1330000081 1/20/2017 6:15:00 8:30:00 1/20/2017 U 28 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL CAUSED BY A HIGH JACKET WATER COMPRESSOR CAN BE RESTARTED. TEMPERATURE EXCESS VENTING DUE TO 011012017 124250 1330000081 1/21/2017 3:00:00 7:15:00 1/21/2017 U 5.2 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL CAUSED BY A FROZEN PRESSURE COMPRESSOR CAN BE RESTARTED. DRAIN. UPDATED DESCRIPTION: EXCESS VENTING DUE TO SHUTDOWN OF EXCESS VENTING IS NECESSARY 01/012017 124250 1330000081 1/22/2017 0:15:00 13:30:00 1/22/2017 U 16.2 VRU COMPRESSOR DUE TO HIGH UNTIL COMPRESSOR CAN BE DISCHARGE PRESSURE CAUSED BY A RESTARTED. FROZEN COOLER. EXCESS VENTING DUE TO SHUTDOWN OF THE VRU EXCESS VENTING NECESSARY UNTIL 01101QO17 124250 1330000081 1/26/2017 20:30:00 23:59:00 1/26/2017 U 42 COMPRESSOR CAUSING A VENT REPAIRS CAN BE MADE AND THE FROM THE BULK OIL TANK DUE TO EQUIPMENT RESTARTED. FREEZING OF INSTRUMENT AIR AND TOTAL PLANT SHUTDOWN, UPDATED DESCRIPTION: EXCESS FLARINGDUETOCOMPLETEPLANT EXCESS VENTING NECESSARY UNTIL 01/012017 E133000ON1 1/26/2017 20:30:00 23:59:00 1/26/2017 U 119.9 SHUTDOWN DUETOLOWOIL REPAIRS CAN BE MADE AND THE PRESSURE IN THE COMPRESSORS EQUIPMENT RESTARTED. AFTER THE INSTRUMENT AIR FROZE. SWANSON RIVER STORAGE January -17 TONB> 1 HR: 850.0 R tDale Plaiwd UPDATED DESCRIPTION: EXCESS VENTING DUE TO SHUTDOWN OF EXCESS VENTING NECESSARY UNTIL THE VRU COMPRESSOR CAUSING A 01/012017 1242W 1330000081 1/27/2017 0:00:00 7:00:00 1/27/2017 U 87 REPAIRS CAN BE MADE AND THE VENT FROM THE BULK OIL TANK EQUIPMENT RESTARTED. DUE TO FREEZING OF INSTRUMENT AIR AND TOTAL PLANT SHUTDOWN. UPDATED DESCRIPTION: EXCESS FLARING DUE TO COMPLETE PLANT EXCESS VENTING NECESSARY UNTIL 011012017 124250 1330000081 1/27/2017 0:01:00 7:00:00 1/27/2017 U 333.1 SH UTDOWN DUE TO LOW OIL REPAIRS CAN BE MADE AND THE PRESSURE IN THE COMPRESSORS EQUIPMENT RESTARTED. AFTER THE INSTRUMENT AIR FROZE. UPDATED DESCRIPTION: EXCESS VENTING DUE TO SHUTDOWN OF EXCESS VENTING NECESSARY UNTIL 01/012 017 124250 1330000081 1/27/2017 00 7::00 23:59:00 1/27/2017 U 20.9 VRU COMPRESSOR FOR REPAIRSCAN BE MADE AND THE UNSCHEDULED MAINTENANCE AS A EQUIPMENT RESTARTED. RESULT OF A BAD BEARING OR POSSIBLE BROKEN VANE. UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL 01/01/2017 124250 1330000081 1/28/2017 0:00:00 23:59:00 1/28/2017 U 294 VENTING FROM TK -22 CAUSED BY REPAIRS CAN BE MADE AND THE VRU SHUTDOWN FOR EQUIPMENT RESTARTED. UNSCHEDULED MAINTENANCE. UPDATED DESCRIPTION: EXCESS 01/012017 124250 1330000081 1/29/2017 0:00:00 23:59:00 1/29/2017 U 29.4 VENTING FROM TK -22 CAUSED BY EXCESS VENTING NECESSARY UNTIL REPAIRS CAN BE MADE AND THE VRU SHUTDOWN FOR EQUIPMENT RESTARTED. UNSCHEDULED MAINTENANCE, UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL 01/012017 124250 1330000081 1/30/2017 0:00:00 23:59:00 1/30/2017 U 294 VENTING FROM TK -22 CAUSED BY REPAIRS CAN BE MADE AND THE VRU SHUTDOWN FOR EQUIPMENT RESTARTED. UNSCHEDULED MAINTENANCE. UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL 01/012017 124250 1330000081 1/31/2017 0:00:00 23:59:00 1/31/2017 U 294 VENTING FROM TK -22 CAUSED BY REPAIRS CAN BE MADE AND THE VRU SHUTDOWN FOR EQUIPMENT RESTARTED. UNSCHEDULED MAINTENANCE. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FAMI ITV QFGnDT ne evnrnrnen nwe nreonerrrnu 1. Facility Number 1330000081 ...- --- ...._. 2. Facility Name 1 Swanson River Storage _- _. ...���__� �.... �............... 3. Field 4. Operator Swanson River Unit I HILCORP ALASKA LLC 5. MonthNear of Disposition I February 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 89,657 Pool Name Pool Code Percent 7. Reinjected" Includes Transferred From, Gas. See Remarks 136,268 8. Flared or vented 1 hour or less 63 9. Flared or vented more than 1 hour (see instr.) 122 SWANSON RIVER, GAS STORAGE 772803 19.27% SWANSON RIVER, GAS STORAGE 772805 80.73% 10. Pilot and Purge 394 11. Assist Gas 0 12. Fuel gas used in lease operations 21,503 13. Other (see instructions) 0 Official Use Only Authorization>1 hr Safety / 22 MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 248,007 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas -Transferred from SRF 0MCF Waste: 17. Transferred from: (Off -lease Gas) 0 Commissioner . S,- / Date 18. Transferred to: (67,080) 19. Remarks: Transferred From: Swanson River Field: Other 15706: *Included in line 7., 8.9.10.12. Other 15706 (Acq Gas for Lease Uses): Transferred To: SRU Field(Hemlock) for Injection. Ind. Line 6.: 111,181 25 087 136,268 8,702 67,080 Injected into Storage 174,842 Transferred Gas used as Fuel: - Storage Inv. 3,755,435 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Printed Name Cortne Der Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psis and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Date 3/21/2017 AAC25.235. (<tL- 4141 1 - 41411 SWANSON RIVER STORAGE FeETw -17 TotAl>1 HR: 122.0 UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTILREPAIRSCANBEMADEANDTHE 02ID1/2017 124250 1330000081 2/2/2017 0:00:00 23:59:00 2/2/2017 U 34.4 VENTING CAUSED BY VRU SHUTDOWN FOR UNSCHEDULED EQUIPMENT RESTARTED. MAINTENANCE. UPDATED DESCRIPTION: EXCESS 02/01201] 124250 1330000081 2/3/2017 0:00:00 23:59:00 2/3/2017 U 34.4 VENTING CAUSED BY VRU EXCESS VENTING NECESSARY UNTIL SHUTDOWN FOR UNSCHEDULED REPAIRS CAN BE MADE AND THE MAINTENANCE. GOO IPMEM'RESTARTED. UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL 02/01/2017 124250 1330000081 2/4/2017 0:00:00 10:00:00 2/4/2017 U 14.3 VENT NG CAUSED BY VRU REPAI RS CAN BE MADE AND THE SHUTDOWN FOR UNSCHEDULED MAINTENANCE. GOO IPMENT RESTARTED. UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL 02/01/2017 124250 1330000081 2/14/2017 1:30:00 13:45:00 2/14/2017 U 17.6 VENTING DUE TO SHUTDOWN OF FIELD 150 PRESSURE SUBSIDED AND VRU COM PRESSOR CAUSED BY HIGH VRU COMPRESSOR CAN BE FIELD 150# PRESSURE. RESTARTED. EXCESS VENTING NECESSARY UNTIL EXCESS VENTING DUE TO PRESSURE DRAIN IS UNPLUGGED 02/01/2017 124250 1330DO0081 2/17/2017 9:00:00 11:00:00 2/17/2017 U 3.6 SHUTDOWN OF VRU COMPRESSOR WITH METHANOL AND TRI-PLEX DUE TO A PLUGGED OR FROZEN PRESSURE DRAIN, AND COMPRESSOR BROUGHT BACK ONLINE, EXCESS VENTING NECESSARY UNTIL EXCESSVENTING DUE TO 02/01/2017 124250 1330000081 2/18/2017 14:30:00 16:00:00 2/18/2017 U 2.1 SHUTDOWN OF VRU COMPRESSOR PRESSURE DRAIN IS UNPLUGGED DUE TO A PLUGGED OR FROZEN WITH METHANOL AND TRI-PLEX AND COMPRESSOR BROUGHT BACK PRESSU RE DRAIN. ONLINE. EXCESS VENTING DUE TO EXCESS EXCESS VENTING NECESSARY UNTIL ENTIG 02/01/2017 124250 1330000081 Z/20/2017 3:30:00 6:30:00 2/20/2017 U 94 SHUTDOWN OF VRU COMPRESSOR UNIT ANDSSARYVRU NTI BE CAUSED BY A HIGH 2ND STAGE RESTARTED. JACKET WATER TEMPERATURE EXCESS VENTING DUE TO 02/01/2017 124250 1330000081 2/20/2017 10:15:00 13:00:00 2/20/2017 U 4.0 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL COMPRESSOR CAN BE RESTARTED. DUE TO HIGH 2ND STAGE SUCTION. EXCESS VENTING DUE TO EXCESS VENTING IS NECESSARY 02/01/2017 124250 1330000081 2/22/2017 8:15:00 9:45:00 2/22/2017 U 2.3 SHUTDOWN OF VRU COMPRESSOR UNTIL COMPRESSOR CAN BE DUE TO FROZEN DISCHARGE. RESTARTED. EXCESS VENTING DUE TO 02/01/2017 124250 1330000081 2/24/2017 8:45:00 10:45:00 2/24/2017 U 29 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING IS NECESSARY ASSOCIATED WITH REROUTING LEX UNTIL COMPRESSOR S CAN BE FEED. RESTARTED. EXCESS VENTING DUE TO EXCESS VENTING IS NECESSARY E02/01)2011 124250 1330000081 2/27/2017 10:30:00 12:00:00 2/2]/201] U 21 SHUTDOWNOFVRU COMPRESSOR UNTIL COMPRESSOR CAN BE CAUSED BY FREEZING OF THE RESTARTED. COOLER. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000061 2. Facility Name Swanson River Storage 3. Field 4,Operator Swanson River Unit HILCORP ALASKA LLC 5. MonthNear of Disposition I March 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold - 534,179 Pool Name Pool Code Percent 7.- Reinjected` Includes Transferred From, Gas. See Remarks 11,016 8. Flared or vented 1 hour or less 137 9. Flared or vented more than 1 hour (see instr.) 52 SWANSON RIVER. GAS STORAGE 772803 41.49% SWANSON RIVER, GAS STORAGE 772805 58.51% 10. Pilot and Purge 294 11, Assist Gas 0 12. Fuel gas used in lease operations 25,888 13. Other (see instructions) 0 Official Use Only Authorization >l he Safety 5-z- MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 571,566 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner �! / Date 18. Transferred to: (194,666) 19. Remarks: Transferred From: Swanson River Field: Other 15706: *Included in Line 7. 8.9.10.12. Other 15706 (Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock) for Injection. Ind. Line 6.: 10,990 26 11,016 45 194,666 Injected into Storage 25,846 Transferred Gas used as Fuel: - Storage Inv. 3,205,946 1 hereby certi4 :hat the foregoing is true and correct to the best of my knowledge. Signature 'D'-� Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 4119120171 SWANSON RIVER STORAGE March -17 Total> 1 HR: $2.0 UPDATED DESCRIPTION: EXCESS VENTING DUE TO FREEING OF THE EXCESS VENTING NECESSARY UNTIL 03/0112017 124250 1330DOMBI 3/4/2017 4:00:00 11:00:00 3/4/2017 U 11.4 VRU IST STAGE COOLER CAUSING A THE COOLER IS THAWED AND THE SHUTDOWN OF THE VRU COMPRESSOR IS RESTARTED. COMPRESSOR. UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL VENTING DUE TO SHUTDOWN OF 03ffiTQD17 124250 1330000081 3/6/2017 4:30:00 15:00:00 3/6/2017 P 17.0 THE PRESSURE DRAIN 15 THAWED VRU COMPRESSOR DUE TO A AND THE COMPRESSOR RESTARTED. FROZEN PRESSURE DRAIN. EXCESS VENTING DUE TO 03/01/2017 124250 1330000081 3/20/2017 0:00:00 16:00:00 3/20/2017 U 7.3 SHUTDOWN OF VRU GESS VENTING NECESSARY UNTIL DUE TO PLANT ESD. COMPRESSOR OMPRESSOR CAN BE RESTARTED. C EXCESS VENTING DUE TO 03/01/2017 124250 1330000081 3/20/2017 11:30:00 14:30:00 3/20/2017 U 1.1 SHUTDOWN OF K-11 COMPRESSOR EXCESS VENTING NECESSARY UNTIL COMPRESSOR CAN BE RESTARTED. DUE TO PLANT ESD. EXCESS VENTING DUE TO EXCESS VENTING NECESSARY UNTIL 03101/2017 124250 1330000081 3/20/2017 11:30:00 14:30:00 3/20/2017 U 1.1 SHUTDOWN OF K-12 COMPRESSOR COMPRESSOR CAN BE RESTARTED. DUE TO PLANT ESD. EXCESS VENTING DUE TO 03101/2017 124250 1330000081 3/20/2017 11:30:00 14:30:00 3/20/2017 U 1.1 SHUTDOWN OF K-14 COMPRESSOR EXCESS VENTING NECESSARY UNTIL COMPRESSOR CAN BE RESTARTED. DUE TO PLANT ESD. EXCESS VENTING DUE TO EXCESS VENTING NECESSARY UNTIL 03101QD17 124250 1330000081 3/20/2017 11:30:00 14:30:00 3/20/2017 U 2.1 SHUTDOWN OF K-17 COMPRESSOR COMPRESSOR CAN BE RESTARTED. DUE TO PLANT ESD. EXCESS VENTING DUE TO EXCESS VENTING NECESSARY UNTIL 03101/2017 124250 1330000081 3/20/2017 11:30:00 14:30:00 3/20/2D17 U 2.1 SHUTDOWN OF PM PLANT DUE TO PM PLANT UNITS CAN BE PLANT ESD. RESTARTED. EXCESS VENTING NECESSARY UNTIL EXCESS VENTING DUE TO FIELD 150# PRESSURE ALLOWED FOR 03/01/2017 12425D 1330000081 3/28/2017 18:30:00 23:59:00 3/28/2017 U 8.8 SHUTDOWN OF VRU COMPRESSOR THE RESTART OF THE VRU DUE TO HIGH FIELD 150# GAS. COMPRESSOR. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name 1 Swanson River Storage 3. Field 4. Operator Swanson River Unit I HILCORP ALASKA LLC 5. Month/Year of Disposition I Aril 2017 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 61,568 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred From, Gas. See Remarks 195,956 8. Flared orvented l hour or less 61 9. Flared or vented more than 1 hour (see instr.) 58 SWANSON RIVER, GAS STORAGE 772803 44.32% SWANSON RIVER, GAS STORAGE 772805 55.68% 10. Pilot and Purge 303 11, Assist Gas 0 12. Fuel gas used in lease operations 24,487 13. Other (see instructions) 0 Official Use Only Authorization >7 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) . Includes Transferred 282,433 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas -Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 7 �! 18. Transferred to: (44,664) Commissioner Date 19. Remarks: Transferred From: Swanson River Field: Other 15708: *Included in Line 7: 8. 9.10. 12. Other 15708 (Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock) for Injection. Incl. Line 6.: 190,204 5 752 195,956 4,135 44,664 Injected into Storage 224,844 Transferred Gas used as Fuel: - Storage Inv. 3,319,560 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature-��� Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.2 5. Printed Name Cortney Der Phone 713-289-2881 Date 511612017 1/--7- SWANSON RIVER STORAGE FII -17 Total > 1 HR: 58.0 EXCESS VENTING DU ETO EXCESSVENTING NECESSARYUNTIL 12:30:00 4/2/2017 P 20 SHUTDOWN OF THE VRU VRU COMPRESSOR CAN BE 04101/2017 124250 1330000081 4/2/2017 11:15:00 COMPRESSOR TO INSTALL A RESTARTED. VARIABLE SPEED FAN ON THE VRU. EXCESS VENTING DUE TO EXCESS VENTI NG NECESSARY UNTIL 04101/2017 124250 1330000081 4/3/2017 1:30:00 3:00:00 4/3/2017 U 2.4 SHUTDOWN OF VRU COMPRESSOR VRU COMPRESSOR CAN BE DUE TO HIGH 150# PRESSURE. RESTARTED. EXCESS VENTING DUE TO SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL IN ORDER TO ADIUSTTHE INTERNAL 04101/2017 124250 1330000081 4/7/2017 9:00:00 123000 4/7/2017 U 5.7 RELIEFS ON BOTH VRU UQUID VRU COMPRESSOR CAN BE RESTARTED. PUMPS FOR 1ST AND 2ND STAGE SCRUBBERS. UPDATED DESCRIPTION: EXCESS VENTING DUE TO SHUTDOWN OF VRU COMPRESSOR CAUSED BY EXCESS VENTING NECESSARY UNTIL 15:00:00 4/8/2017 U 16.4 FREEZING OF THE PRESSURE DRAIN PRESSURE DRAIN LINE THAWED AND 04/0112017 124250 1330000081 4/8/2017 5:00:00 LINE. WHILE THAWING THE COMPRESSOR RESTARTED. PRESSURE DRAIN LINE, A VARIABLE SPEED CONTROLLER FOR THE COOLING FAN WAS INSTALLED. UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL 4/9/2017 11:00:00 18:00:00 4/9/2017 U 11.6 VENTING DU E TO SHUTDOWN OF PROGRAMM ING ISSU E FIXED AND 04MI12017 124250 1330000081 VRU COMPRESSOR CAUSED BY COMPRESSOR IS RESTARTED. PROGRAMMING ISSUES. EXCESS VENTING DUETO EXCESS VENTING NECESSARY UNTIL 041012017 124250 1330000081 4/19/2017 0:00:00 8:30:00 4/19/2017 U 7.0 SHUTDOWN OF VRU CAUSED BY IST VRU CAN BE RESTARTED IN MANUAL AND 2ND STAGE VFD FAULT. MODE. EXCESS VENTING NECESSARY UNTIL EXCESS VENTING DUE TO RPM5 FOR RE 2ND AN 04/0112017 124250 1330000081 4/21/2017 1:30:00 3:00:00 4/21/2017 U 2.4 SHUTDOWN OF VRU COMPRESSOR COMPRND ESSOR LOWERED AND COMPRESSOR CAN LOWERED DUE TO IST STAGE VFD FAULT. BE RESTARTED. EXCESS VENTING DUE TO EXCESS VENTING NECESSARY UNTIL 04/01/2017 124250 1330000081 4/25/2017 0:00:00 6:30:00 4/25/2D17 U 10.7 SHUTDOWN OF VRU COMPRESSOR COMPRESSOR CAN BE RESTARTED. DUE TO HIGH 150# PRESSURE. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name 1 Swanson River Storage 3. Field 4. Operator Swanson River Unit I HILCORP ALASKA LLC 5. Month/Year of Disposition I May 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 498,034 Pool Name PoolCode Percent 7. Reinjected' Includes Transferred From, Gas. See Remarks 10,233 8. Flared or vented 1 hour or less 43 9. Flared or vented more than 1 hour (see instr.) 12 SWANSON RIVER, GAS STORAGE 772803 42.16% SWANSON RIVER, GAS STORAGE 772805 57.84% 10. Pilot and Purge 289 11, Assist Gas 0 12. Fuel gas used in lease operations 26,794 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety /2 MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 535,405 Lease Use � I `� 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste:I MCF 17. Transferred from: (Off -lease Gas) 0 -177 18. Transferred to: (179,752) Commissioner Date 19. Remarks: Transferred From: Swanson River Field: Other 15708: *Included in Line 7 8.9.10.12. Other 1570B (Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock) for Injection. Incl. Line. 6.: 10,194 39 10,233 113 179,752 Injected into Storage 19,493 Transferred Gas used as Fuel: - Storage Inv. 2,804,734 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature-����-f/-� Printed Name Cortney Der Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F Authority 20 Phone 713-289-2881 Date 6/20/2017 AAC25.235. SWANSON RIVER STORAGE May -17 Total> 1 HR: 13.0 EXCESS VENTING DUE TO EXCESS VENTING NECESSARY UNTIL 05/01/2017 124250 1330000081 5/4/2017 7:15:00 9:15:00 5/4/2017 U 3.4 SHUTDOWN OF VRU COMPRESSOR THE VRU COMPRESSOR CAN BE DUE TO HIGH 150 PRESSURE. RESTARTED. EXCESS VENTING NECESSARY UNTIL EXCESS VENTING DUE TO 05/0112017 124250 1330000081 5/5/2017 5:15:00 6:45:00 5/5/2017 U 2.5 SHUTDOWN OF VRU COMPRESSOR AIR IS BLED OUT, LUBE PUMPS ARE FROM LOW LUBE FLOW. PRIMED AND VRU COMPRESSOR IS RESTARTED. EXCESS VENTING DUE TO 124250 1330000081 5/14/2017 9:15:00 10:45:00 5/14/2017 U 2.5 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL COMPRESSOR IS RESTARTED. ON HIGH 150 PRESSURE. EXCESS VENTING DUE TO SHUTDOWN OF THE VRU 05/01/2017 124250 1330000081 5/16/2017 23:00:00 19090 5/17/2017 U 1.8 COMPRESSOR ON HIGH DISCHARGE EXCESS VENTING NECESSARY UMIL COMPRESSOR IS ESARU PRESSURE CAUSED BY HIGH 150p GAS FROM BRINGING ON A WELL. EXCESS VENTING DUE TO SHUTDOWN OF THE VRU 05/0112017 124250 1330000081 5/16/2017 23:0:00 1:00:0 5/17/2017 U 1.8 COMPRESSOR ON HIGH DISCHARGE EXCESS VENTING NECESSARY UNTIL PRESSURE CAUSED BY HIGH 15011 COMPRESSOR IS RESTARTED. GAS FROM BRINGING ON A WELL. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODDCEn GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4.Operator HILCORP ALASKA LLC 5. Month/Year of Disposition I June 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 13,644 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred From, Gas. See Remarks 67,312 8. Flared or vented 1 hour or less 16 9. Flared or vented more than 1 hour (see instr.) 3 SWANSON RIVER, GAS STORAGE 772803 0.00% SWANSON RIVER, GAS STORAGE 772805 100.00% 10. Pilot and Purge 32 11. Assist Gas 0 12. Fuel gas used in lease operations 2,945 13. Other (see instructions) 0 Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) • Includes Transferred 83,952 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation 2 J MCF to 16. Purchased gas -Transferred from SRF 0 Wase: MCF 17. Transferred from: (Off -lease Gas) 0 ,. G 18. Transferred to: (13,148) ommissioner Date 19. Remarks: Reinjected/Transferr Swanson River Field: ed From: Other 15708: *Included in Line 7: 8.9.10.12. Other 15708 (Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock)for Injection. Incl. Line 6.: 65,278 2 034 67,312 1,403 13,148 Injected into Storage 69,694 Transferred Gas used as Fuel: - Storage Inv. 2,855,406 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature ��%-Cru Printed Name Cortney Dyer Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Date 7/19/2017 AA�19 119 06/01/2017 1 124250 1 1330000061 06/012017 1 124250 1 1330000081 6/23/2017 8:00:00 6/25/2017 8:45:00 150000 6/23/2017 10:30:00 6/25/2017 UPDATED DESCRIPTION: EXCESS EXCESS VENTING NECESSARY UNTIL 2.7 VENTING DUE TO LIQUIDS LIQUIDS UNLOADING COMPLETE UNLOADING OF WELL 213-15. AND WELL BROUGHT BACK ONLINE. EXCESS VENTING DUE TO PM PLANT 03 EMERGENCY SHUTDOWN CAUSING EXCESS VENTING NECESSARY UNTIL A SHUTDOWN OFTHE VRU COMPRESSOR CAN BE RESTARTED. COMPRESSOR. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PROn11CFn nAC n1.CPOA1T10N 1. Facility Number 1330000081 1 2. Facility Name Swanson River Storage 3. Field 4. Operator Swanson River Unit I HILCORP ALASKA LLC 5. Month/Year of Disposition I July 2017 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 4,766 Pool Name Pool Code Percent 7. Reinjected• Includes Transferred From, Gas. See Remarks 65,575 8. Flared or vented 1 hour or less 6 9. Flared or vented more than 1 hour (see instr.) 0 SWANSON RIVER, GAS STORAGE 772803 0.00% SWANSON RIVER, GAS STORAGE 772805 100.00% 10. Pilot and Purge 17 11. Assist Gas 0 12. Fuel gas used in lease operations 1,667 13. Other (see instructions) 0 Official Use Only Authorization 11 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 72,031 Lease Use MCF 15, NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF p Waste: MCF 17. Transferred from: (Off -lease Gas) 2,746 18. Transferred to: (4,626) Commissioner Date 19. Remarks: Reinjected/T7ansferr Swanson River Field: ed From: Other 15708: *Included in Line 7: 8.9.10. 12. Other 1570B(Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock) for Injection. Incl. Line 6.: 63,986 1,589 65,575 1,157 4,626 Injected into Storage 66,326 Transferred Gas used as Fuel: - Storage Inv. 2,917,085 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature-ctte�.l%pef Printed Name Cortney Der Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Date 8!18!2017 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name 1 Swanson River Storage 3. Field 4. Operator Swanson River Unit I HILCORP ALASKA LLC 5. Month/Year of Disposition I August 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 292 Pool Name Pool Code Percent 7. Reinjected` Includes Transferred From, Gas. See Remarks 136,511 8. Flared or vented 1 hour or less 54 9. Flared or vented more than 1 hour (see instr.) 93 SWANSON RIVER, GAS STORAGE 772803 100.00% SWANSON RIVER, GAS STORAGE 772805 0.00% 10. Pilot and Purge 89 11. Assist Gas 0 12. Fuel gas used in lease operations 9,608 13. Other (see instructions) 0 .Official Use Only Authorization>1 hr: Safety 93 F 14. TOTAL VOLUME (ITEMS 6-13) . Includes Transferred 146,647 Lease Use C 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas -Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 33,596 Commissioner IL f, Date 18. Transferred to: (286) 19. Remarks: ReinjectedfTransferr Swanson River Field: ed From: Other 1570B: `Total Included in Line 7., 8. 9. 10. 12. Other 15706 (Acq Gas for Lease Uses): 8.9.10.12. Storage Production for Lease Uses 112720 23,791 136,511 9,807 37 Injected into Storage 136,605 Storage Inv. 3,053,267 Transferred To: 286 'SRU Field (Hemlock) for Injection. Incl. Line 6.: 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature .O1/.0 Printed Name Cortney Der Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Date 9/19/2017 AAC25.235. SWANSON RIVER STORAGE Au ust-17 TotaU 7 HR: 93.0 EXCESS VENTING DUE TO SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL 08/01/2017 124250 1330000081 8/5/2017 17:45:00 19:15:00 8/5/2017 U 0.9 CAUSED BY HIGH 150 PRESSURE FROM SHUTDOWN OF K-13 COMPRESSOR CAN BE RESTARTED. COMPRESSOR. UPDATED DESCRIPTION: EXCESS FLARING DUE TO SHUTDOWN OF K- 13 COMPRESSOR ON A HOT VALVE, 08/01/2017 124250 1330000081 8/9/2017 17:00:00 18:45:00 8/9/2017 U 87.8 K-18 COMPRESSOR DUE TO A BAD EXCESS FLARING NECESSARY UNTIL 13 COMPRESSOR IS STARTED UP POWER CYLINDER REARING, AND K- 15 COMPRESSOR DUETOA BAD AND PIGGING IS CURTAILED. BEARINGTRIP DURING PIGGING OF 1570. UPDATED DESCRIPTION: EXCESS VENTING DUE TO SHUTDOWN OFEXCESS VENTING NECESSARY FOR 08/01/2017 124250 1330000081 8/9/2017 17:00:00 23:59:00 8/9/2017 U 43 THE VRU COMPRESSOR ON A IST SAFE SHUTDOWN OF COMPRESSOR. STAGE VFD FAULT. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FAru Iry RFPnRT nF PPnnl IrP11 nAR nMIDACITInM 1. Facility Number 1330000002 -------- --- --- 2. Facility Name 1 Swanson River ---------'--'—......_.- 3. Field 4. Operator Swanson River Unit HILCORP ALASKA LLC 5. MonthNear of Disposition I September 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution of Total Volume, of each pool as a percent 6. Sold 33,380 Pool Name Pool Code Percent 7. Reinjected 420,404 SWANSON RIVER, HEMLOCK 772100 88.42% SWANSON RIVER, HEM F/STERLING UNDEF 772105 0.00% 8. Flared or vented 1 hour or less 3,244 SWANSON RIVER, TVONEK UNDEFINED 772500 0.09% SWANSON RIVER, BELUGA UNDEFINED 772520 0.00% 9. Flared or vented more than 1 hour (see instr.) 11 SWANSON RIVER, STERLING UNDEFINED 772550 11.49% 10. Pilot and Purge 1,090 11. Assist Gas 0 12. Fuel gas used in lease operations 106,392 13. Other (see instructions) 0 Official Use Only Authorization >1 hr 9� �r ' g Safely f / MCF 14. TOTAL VOLUME (ITEMS 6-13) 564,521 Lease Use MCF 15. NGL Gas Equivalent (mcf) 4,692 Conservation MCF 16. Purchased gas - Rental Return Gas 475,537 Waste: MCF 17. Transferred from: (Off -lease Gas) g,37g/l Commissioner 3 4? 48 Date 18. Transferred to: (23 311) 19. Remarks: SOLD SRU Field to Enstar (royalty -bearing) SRU Field to Enstar (non -royalty H Sand) SRU to Storage (royalty- bearing) SRU to Storage (non -royalty H Sand) REINJECTED SRU Royalty -Bearing REINJ back into Hemlock SRU Non -Royalty H Sand REINJ back to Hemlock 1,300 8,769 3,007 20,304 54,274 366,130 TRANSFERRED TO Ind. Line 6 Sold/Inj to Storage TRANS FROM Storage/Acq Gas Injected into Hemlock H 23,311 8,379 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature 67"+ A1W Printed Name Cortne Der Note: All volumes must be corrected Title Production Analyst to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Date 10/19/2017 AAC25.235. SWANSON RIVER UNIT Se tember47 Total I1 HR: 11.0 EXCESS VENTING DUE TO 09/01/2017 1242501330000002 9/30/2017 8:00:00 9:30:00 9/30/201] U 11.0 UNSCHEDULED SHUTDOWN OF VRU EXCESS VENTING NECESSARY UNTIL COMPRESSOR ONA RECYCLE VALVE COMPRESSOR CAN BE RESTARTED. ISSUE. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRnn11CFn RAS nISPORITlnN 1. Facility Number 1330000081 1 2. Facility Name Swanson River Storage 3. Field 4. Operator Swanson River Unit I HILCORP ALASKA LLC 5. MonthNear of Disposition I October 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 39,377 Pool Name PoolCode Percent 7. Reinjected' Includes Transferred From, Gas. See Remarks 28,409 8. Flared or vented 1 hour or less 3 9. Flared or vented more than 1 hour (see instr.) 54 SWANSON RIVER, GAS STORAGE 772803 98.12% SWANSON RIVER, GAS STORAGE 772805 1.88% 10. Pilot and Purge 50 11. Assist Gas 0 12. Fuel gas used in lease operations 5,247 13. Other (see instructions) 0 Official Use Only Authorization >t hr:''//!' 0164 Safety MCF 14. TOTAL VOLUME (ITEMS 6.13). Includes Transferred 73,140 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Wa e: MCF 17. Transferred from: (Off -lease Gas) 0 pgzi�f t/1.1 Commissioner 3-/19-/S Date 18. Transferred to: (38,398) 19. Remarks: Transferred From: Swanson River Field: Other 1570B: *Included in Line 7 8.9.10.12. Other 15708 (Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock) for Injection. Incl. Line 6.: 27,837 572 28,409 933 38,398 Injected into Storage 31,187 Transferred Gas used as Fuel: - Storage Inv. 3,061,172 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Printed Name Corine Der Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Date 11/21/2017 AAC25.235. SWANSON RIVER STORAGE October -17 ToWl> 1 HR: 54.0 U PDATED DESCRIPTION: EXCESS EXCESS FLARING G NECESSARY UNTIL 1010112017 124250 1330000081 10/2]/201] 12:15:00 13:50:00 10/27/2017 U 47.9 FLARING DUE TO POWER OUTAGE PLANTANFIELD CAN BE SHUTTING DOWN THE PLANT AND FIELD. RESTARTED. EXCESS VENTING DUE TO 10/0112017 124250 1330000081 10/2]/201] 12:15:00 15:45:00 10/2]/201] U 1.2 SHUTDOWN OF VRU COMPRESSOR EXCESS VENTING NECESSARY UNTIL DUE TO HEA POWER OUTAGE. COMPRESSOR CAN HE RESTARTED. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY RPPORT OF PRnr111CF11 OAS nISPOSITION 1. Facility Number 1330000081 2. Facility Name 1 Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. Month/Year of Disposition I November 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 69,430 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred From, Gas. See Remarks 43,607 8. Flared or vented 1 hour or less 13 9. Flared or vented more than 1 hour (see instr.) 10 SWANSON RIVER, GAS STORAGE 772803 22.85% SWANSON RIVER, GAS STORAGE 772805 77.15% 10. Pilot and Purge 75 11. Assist Gas 0 12. Fuel gas used in lease operations 7,897 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: (6(%g Safety i MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 121,032 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Wasl : MCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: (61,749) Commissioner Date 19. Remarks: Transferred From: Swanson River Field: Other 15708: *Included in Line 7: 8. 9.10.12. Other 15708 (Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock) for lnjec6on. Ind. Line 6.: 42,896 711 43,607 778 61,749 Injected into Storage 50,927 Transferred Gas used as Fuel: - Storage Inv. 3,028,133 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature �..eef+r� �-D-GP Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.23A Printed Name Cortney Der Phone 713-289-2881 Date 12/21/2017 SWANSON RIVER STORAGE November -17 Total> 1 HR: 10.1 O No FadBt No Date Flared StartTime Entli Time End Date Plannetl MCF Desai ion of Flan Evert ACA onEXCESS VENTING DUE TO SHUTDOWN OF THE VRU EXCESS VENTI NG NECESSARY UNTIL 124250 1330000081 11/5/2017 11:00:00 12:15:00 11/5/2017 U OJ COMPRESSOR DUE TO HIGH SYSTEM COMPRESSOR IS RESTARTED. PRESSURE CAUSED BY THE POWER FtDste BUMP. EXCESS VENTI NG DUE TO EXCESS VENTING NECESSARY U MIL SHUTDOWN OF VRU COMPRESSOR SCHEDULED MAINTENANCE IS 124250 1330000081 11/18/2017 12:30:DD 17:00:00 11/18/2017 P 25 TO ADJUST THE PITCH OF THE FAN COMPLETE AND COMPRESSOR IS BLADE. RESTARTED. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Stora a 3. Field 4. Operator Swanson River Unit I HILCORP ALASKA LLC 5. MonthNear of Disposition I November 2017 Disposition Volume MCF 20. For production from multiple pools, list contribution Total Volume. of each pool as a percent of 6. Sold 69,430 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred From, Gas. See Remarks 43,607 8. Flared or vented 1 hour or less 13 9. Flared or vented more than 1 hour (see instr.) 10 SWANSON RIVER, GAS STORAGE 772803 22.85% SWANSON RIVER, GAS STORAGE 772805 77.15% 10. Pilot and Purge 75 11. Assist Gas 0 12. Fuel gas used in lease operations 7,897 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6.13)' Includes Transferred 121,032 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: JIMCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: (61,749) Commissioner Date 19. Remarks: Transferred From: Swanson River Field: Other 15706: *Included in Line 7: 8.9.10.12. Other 15708 (Acq Gas for Lease Uses): Transferred To: SRU Field (Hemlock) for Injection. Inc. Line 6.: 42,896 711 43,607 776 61,749 Injected into Storage 50,927 Transferred Gas used as Fuel: - Storage Inv. 3,028,133 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature �' �% Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 12/21/2017 SWANSON RIVER STORAGE November -17 Total > 1 HR: 10.1 EXCESS VENTING DUE TO SHUTDOWN OF THE VRU EXCESS VENTING NECESSARY UNTIL 11/17/2017 124250 1330000081 11/5/2017 11:00:00 12:15:00 11/5/3017 U 0.7 COMPRESSOR DUE TO HIGH SYSTEM COMPRESSOR IS RESTARTED. PRESSURE CAUSED BY THE POWER BUMP. EXCESS VENTI NG DUE TO EXCESS VENTING NECESSARY UNTIL SHUTDOWN OF VRU COMPRESSOR SCHEDULED MAINTENANCE IS 11/17/2017 124250 1330000081 11/18/2017 12:30:00 1]:00:00 11/18/2037 p 25 TOADIUSTTHE PITCH OFTHE FAN COMPLETE AND COMPRESSOR IS BI -ADE. RESTARTED. CA g .. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 2. Facility Name 1330000081 Swanson River Storage Disposition 3. Field Swanson Volume MCF 4. Operator 5. MonthNear of Disposition River Unit HILCORP ALASKA LLC I December 2017 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 70,640 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred From, Gas. See Remarks 86,614 8. Flared or vented 1 hour or less 81 9. Flared or vented more than 1 hour (see instr.) t6 SWANSON RIVER, GAS STORAGE 772803 15.50% SWANSON RIVER, GAS STORAGE 772805 84.50% 10. Pilot and Purge 86 11. Assist Gas 0 12. Fuel gas used in lease operations 9,201 13. Other (see instructions) 0 Official Use Only Authorization>1 ,hLr: 2��6(1� �( Safely I MCF 14. TOTAL VOLUME (ITEMS 6-13)" Includes Transferred 166,638 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: IMCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: (55.608) Commissioner Date 19. Remarks: Transferred From: Swanson River Field: 84,089 Injected into Storage 6,010 Other 15708: 2 525 Transferred Gas used as Fuel: - *Included in Line 7: 86,614 8.9.10.12. Other 1570B (Acq Gas for Lease Uses): 1,404 Storage Inv. 3,034,143 Transferred To: SRU Field(Hembck) for Injection. Inct. Line 6.: 65,608 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature -s2A% A9.Nti� Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AA Printed Name Cortney Der Phone 713-289-2881 Date 1/22/20181 December -17 Total> 1 HR: 16.0 SWANSON RIVER STORAGE EDate Plawd MCF - D&wFi tionofflarin Event Action Taken to Minimize Volume M m RatDate OoNo I FwkyNo Date Flared Start Time. Eft Time EXCESS VENTING DUE TOA POWER EXCESS VENTING NECESSARY UNTIL 12101f2017 124250 1330000081 12/1/2017 11:00:00 14:30:00 12/1/2017 U 20 OUTAGE RESULTING IN SHUTDOWN COMPRESSOR CAN BE RESTARTED. OF VRU COMPRESSOR. UPDATED DESCRIPTION: EXCESS VENTING DUE TO UNSCHEDULED EXCESS VENTING NECESSARY UNTIL 12101/2017 124250 1330000081 12/13/2017 0:00:00 23:59:00 12/13/2017 U 13.2 SHUTDOWN OF K-17 COMPRESSOR COMPRESSOR CAN BE RESTARTED. 17 TIMES THROUGHOUTTHE DAY. EXCESS VENTING DUET FOUR SHUTDOWNS OF K-18 COMPRESSOR EXCESS VENTING NECESSARY FOR 12/012017 124250 1330000081 12/14/2017 0:30:0 5:00:00 12/14/2017 P 0.8 ANDSWAPPINGTO K-17 SAFE SWAPPING OF COMPRESSORS. COMPRESSOR.