Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutSR Swanson River Storage Gas DispositionState of Alaska AOGCC Gas Disposition Files Year: 2014 Facility: SR Swanson River Storage Operator: HILCORP STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator HILCORP ALASKA LLC 5. Month/Year of Disposition Janua 2014 Disposition Volume MCF 20. For production from multiple pools, list contribution Volume. of each pool as a percent of Total 6. Sold 54,116 pool Name Pod Code Percent 7. Reinjected` Includes Transferred Gas. See Remarks 214,995 8. Flared or vented 1 hour or less 11 9. Flared or vented more than 1 hour (see Instr.) 0 SWANSON RIVER, GAS STORAGE 772803 32.24% SWANSON RIVER, GAS STORAGE 772805 67.76% 10. Pilot and Purge 924 11. Assist Gas 0 12. Fuel gas used In lease operations 41,751 13. Other (see instructions) 0 Authorization �1 hr: Safely MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 311,797 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas- Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field Other 15706 106,466 108,529 214,995 Injected into Slorage 214,995 Transferred Gas used as Fuel: - Storage Inv. 3,067,329 1 hereby certify that the foregoing is true and correct to the best of my knowledge. signaturei �� Printed Name Coriney Der Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F. Authority, 20 Phone 713-289-2620 Date 3/20!2014 AAC25.235. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUC 1. Facility Number 2. Facility Name 1330000081 Swanson River Storage Dis ositlon ED 3. Field Svranson Volume MCF GAS River DISPOSITION 4. Operator 5. Monlh/Vear of Disposition Unit I HILCORP ALASKA LLC i January 2014 20. For production from multiple pools, list contribution of each pool as a percent or Total Volume. 6. Sold 160,383 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas- See Remarks 57,723 8. Flared or vented 1 hour or less 23 9. Flared or vented more than 1 hour (see instr.) 204 SWANSON RIVER, GAS STORAGE 772803 42.15% 6WANSON RIVER, GAS STORAGE 772805 57.65% 10. Pilot and Purge 609 11. Assist Gas 0 12. Fuel gas used in lease operations 28,751 13. Other (see Instructions) 0 Official Use'Only- Authorization >1 hr. ty rLIa"Ise MCF 14. 70TAL VOLUME (ITEMS 6-13)' Includes Transferred 247,693 Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferretl from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 / r� Commissioner Data 18. Transferred to: 0 19. Remarks: Transferred From Swanson River Field 57,700 Injected into Storage 57,723 Other 15706 23 Transferred Gas used as Fuel: - 57,723 Storage Inv. 2,949,135 1 hereby certify that the foregoing Is true and correct to the best of my knovAedge. Note: All volumes must be connected to Signature Title Production Analyst pressure of 14.65 psle and to a temperature of 60o F. Authority 20 Printed Name Cortney Dyer Phone 713-289-2620 Date 2119120141 AAC25.235. V�� OR FLARING EVENTS GREATER THAN 1 HOUR - --- -Flared - ,-- Action Taken to e R IDate. 7 p, Faolht No `. Date Start Time EndingTime End Date Planned _ MCF 1 Description Fianna Event- ,MNimIz _ Volume ' Excess flaring necessary until 01/0112014 124250 1330000081 01/01/14 12:30:00 PM 2:00:00 PM 01/01/14 U 7 Excess flaring due to V-5 Pump Valve the Dump Valve Controller being opened. could be adjusted. 01/01/2014 124250 1330000081 01/02/14 11:00:00 AM 1:00:00 PM 01/02/14 U 11 Excess flaring due to the shutdown of Excess flaring necessary until K- 8 could be started, loaded and Compressor K-8. returned back to service. Excess venting due to the shutdown 01/01/2014 124250 1330000081 - 01/02/14 11:00:00 A :00 PM 01/02/14 U 2 of Compressor K-22 becasue of high Excess venting necessary until K-22 could be started, loaded discharge pressure following the and returned back to service. shutdown of K-8. Excess venting due to the Excess venting necessary until 01/0112014 124250 1330000081 01/07/14 8:15:00 AM 5:00:00 PM 01/07/14 U g unscheduled shutdown of line could be depressurized Compressor K-22 caused by and cleared with plugged discharge line. methanol/xViene. 01/07/2014 124250 1330000081 01/15/14 12:00:00 AM 3:00:00 PM 01/15/14 U 97 Excess venting to a of ter Excess venting necessary until the water pump could be Compreue K-22. pump on Compressor K-22. ssor replaced. Excess venting due to a last Excess venting necessary until 01/0112014 124250 1330000081 01/25/14 3:00:00 AM 11:59:00 PM 01/31/14 U 159 Compressor Piston in K-22. Venting a new piston and associated will be ongoing into February. parts are received. 6. Sold ups osifien 7. Reinjected' Includes Transferred Gas. See Remarks 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 h our (see instr.) 10. Pilot and Purge 11. Assist Gas 12. Fuel gas used in lease o Aerations 13. Other (see fnstruchons) 14. TOTAL VOLUME (ITEMS 6.13 Includes Transferred 15. NGL Gas Equivalent 16. Purchased gas - Transferred from m SRF 7. 7ransfemetl from: (_,,-lease Gas 8. Transferred to: Transferred From Swanson River Field Other 15708 MY ALASKA OIL AND GAS STATE OF ALASKA CONSERVATION COMMISSIONFACIL REPORT pOOr 111,394 35.098 13 32 0 2,780 0 149,319kWaste�'� "' - Safety0Lease Use0Conserva& 0 0 35,089 0 Inletted into Storage 35, Trans a ,G, used as Fuel: 56,061 Storage Inv. �— 3,169,864 as Pressure of 14.65 — �urrectec temperatureof 6Oo Asia and to a G A ^ F. Authority 20 RECEIVED STATE OF ALASKA MAR 23 2015 ALASKA OIL AND GAS CONSERVATION COMMISSION 1. FACH- i r K= KI or FKODUCED GAS DISPOSITION Facility Number 2. Facility Name - ` 1330000081 Swanson River Storage 3. Fieltl 4. Operator p Swanson River Unit HILCORP ALASKA LLC 5. Mon -df Disposition Dis osition Volume MCF February2015 20. For production ........ ultiple pools, list contribution of each pool as a percent of Total 6. Sold 140,313 Volume. 7. Reinjected' Includes Transferred Gas. See Remarks Pool Name Pool Cotle Percent 27,787 8. Flared or vented 1 hour or less 6 9. Flared or vented more than 1 hour (see instr.) 1 SWANSON RIVER, GAS STORAGE 772803 27.39% 10. Pilot and Purge SWANSON RIVER, GAS STORAGE 77289572.61% 15 11. Assist Gas 0 12. Fuel gas used in lease operations 2,720 13. Other (see instructions) 0 Official Use Onl 14. TOTAL VOLUME (ITEMS 6-13) *Includes TransferretlSafety Authorization>1 hr: ! MCF 170,842 15. NGL Gas Equivalent Lease Use MCF 0 16. Purchased gas -Transferred from SRF Conservation MCF 0 17. Transferred from: (Off -lease Gas) Waste. MCF 0 _u 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 27,776 Injected into Storage 139,158 Other 157013 11 Transferred Gas used as Fuel: - 27,787 Storage Inv, 3,206,000 1 hereby certify that the foregoing iisstrtrue and to the best of my knowledge. dccorrect t Signature l�'�-may //L�i2. volumes must be corrected to Title Production Analyst [No—tteTAN pressure of 14.65 psia and to a Printed Name Cortne Der Phone 713-289-2881 temperature of 600 F. Authority 20 Date 3/11/2015 AAC25.235. VTL- 4/i6/1S OR FLARING EVENTS GREATER THAN 1 HOUR Accton Taken to Minimize R tDate O No F..iI,tVNo Date Flared Start Time Ending Time End Date Planned MCF Description of Flaring Event Volume Excess flaring due to unscheduled Excess flaring necessary until 02/012015 124250 133MOW81 2/1/2015 1:00:00 PM 4:00:00 PM 2/1/2015 U 1.0 maintenance in the Plant causing maintenance could he emergency shutdown. completed. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPORMnN 1. Facility Number 1330000081 2. FacilityName Swanson River Stora a 3. Field Swanson River Unit 4, Operator HILCORP ALASKA LLC 5. Month/Year of Disposition March 2014 Disposition Volume MCF 20. For production from multiple pools, list contribution Volume. of each pool as a percent of Tota! 6. Sold 4 Pool Name Pool Code Percent 7. Reinjected* Includes Transferred Gas. See Remarks 585,727 8. Flared or vented 1 hour or less 2 9. Flared or vented more than i hour (see Instr.) 2 SWANSON RIVER, GAS STORAGE 772803 0.00% SWANSON RIVER. GAS STORAGE 772805 100.00% 10. Pilot and Purge 454 11. Assist Gas 0 12. Fuel gas used in lease operations 49,777 13. Other (see instructions) 0 ri.;"1tw`Sr6vii"»ri3 cni ',.,',�k< �n"'7i18?A1". Lla&'L^i9L.ECIAF wo N^,. ts'4�3.4w.it1�?. rt,v , x� ' Authorization>1 hr. Safety MCF 14. TOTAL VOLUME (ITEMS 6.13) • Includes Transferred 635,966 Lease Use MCF 15. NGL Gas Equivalent p Conservation MCF 16. Purchased gas - Transferred from SRF p Waste: MCF 17. Transferred from: (Off -lease Gas) 0 Commissioner Date 18. Transferred to: 0 19, Remarks: Transferred From Swenson River Field Other 15708 195,307 390,420 585,727 Injected into Storage 585,727 Transferred Gas used as Fuel: - Storage Inv. 3,653,051 1 hereby certify that the foreglog . UQis true and comet[ to the best of my knowledge. Signature Printed Name Conne Dye / Note: All volumes must be corrected to Title Production Analyst pressure of 14.65 psis and to a temperature of 60o F. Authority 20 Phone 713-289-2881 Date 4/79120141 AAC25.235. � = N !OR FLARING EVENTS GREATER THAN I HOUR 7 4fN W Iob =OfF4 lmg� Excess venting necessary until proper preventative 0310112014 724250 1330000081 3/23/2014 9:30:00 AM 11:00:ODAM 03123/14 p 2 scheduled Maintenance. maintenance was performed and compressor could be brought back online. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION ooILUIC5 1 reC V!SPOSITIt1N 1. Facility Number 2. Facility Name 1330000081 Svranson River Storage Disposition 3. Field Swanson Volume MCF 4. Operator 5. Monthlyear of Disposition River Unit HILCORP ALASKA LLC March 2014 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Percent 7. Reinjected` Includes Transferred Gas. See Remarks 639,600 8. Flarad or vented 1 hour or less 16 ;RIVER;STORAGER772803 PSWANSON0.000%100.00% 9. Flared or vented more than 1 hour (see Instr.) 3 10. Pilot and Purge 627 11. Assist Gas 0 12. Fuel gas used in lease operations 68,666 13. Other (see instructions) 0 Official Use Only. - -. - Authorization >1 hr: Safety MCF 14, TOTAL VOLUME (ITEMS 6.13) • Includes Transferred 708,912 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas- Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0� G' l 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 312,079 Injected Into Storage 639,600 Other 15708 396,633 Transferred Gas used as Fuel: 69,312 708,912 Storage Inv. 3,657,774 1 hereby certify that the foregoin ntl correct to the best of my knowledge. Signetur �� Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortne Der Phone 713-289-2881 Date 4/2212014 yLl� Gl3!! OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Mlnlmlze R (Dale OpNo FaceityNo Date Flared Stan Time - Ending Time End Data Planned MCF - DeSart tionrii Flaring Covent - Voiume - - Excess venting necessary until proper preventative 03701/2014 124250 1330000081 3/23/2014 9:30:00 AM 11:00:00 AM 03/23/14 P 3 Scheduled Maintenance, maintenance was performed and compressor could be brought back online. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name 1 Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. Month/Year of Disposition April 2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 101,365 Pool Name Pool Code Percent 7. Reinjected* Includes Transferred Gas. See Remarks 72,414 8. Flared or vented 1 hour or less 69 9. Flared or vented more than 1 hour (see instr.) 12 SWANSON RIVER, GAS STORAGE 772803 41.06% SWANSON RIVER, GAS STORAGE 772805 58.94% 10. Pilot and Purge 458 11. Assist Gas 0 12. Fuel gas used in lease operations 36,464 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety `Z MCF 14. TOTAL VOLUME (ITEMS 6.13) * Includes Transferred 210,782 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Vyaste: MCF 17. Transferred from: (Off -lease Gas) 0 Z� _ / 18. Transferred to: 0 Commissioner Dale 19. Remarks: Transferred From Swanson River Field 66,768 Injected into Storage 72,414 Other 1570B 5,646 Transferred Gas used as Fuel: - 72,414 Storage Inv. 3,587,097 1 hereby certify that the fore o" tr o rrect to the best of my knowledge. Signature Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 5/20/2014 VL -F 1i1741lei OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDate O No FacilitvNo. Date Flared Start Time Endinct Time End Date Planned MCF Description of Flaring Event Volume Excess venting due to unscheduled 04/01/2014 124250 1330000081 4/6/2014 12:00:00 AM 2:00:00 PM 04/06/14 U 3 shutdown of Compressor K-22 due to Unscheduled Maintenance. the lose of the fin fan cooler belt. Excess Flaring due to unscheduled 04/01/2014 124250 1330000081 04/10/14 10:00:00 PM 11:59:00 PM 04/10/14 U 6 shutdown of the Lex Plant to work on Unscheduled Maintenance. the therminol heater. Excess venting due to scheduled 04/01/2014 124250 1330000081 04/11/14 F107AM11:45:OOaM 04/11/14 P 3 maintenance including an oil change Scheduled Maintenance. and filterchange on the K-22 Compressor. Corrected STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator "'to' ALASKA LLC 5. MonthlYear of Disposition I May 2014 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 79,506 Pool Name Pool Code Percent 7. Reinjected* Includes Transferred Gas. See Remarks 86,061 8. Flared or vented 1 hour or less 22 9. Flared or vented more than 1 hour (see instr.) 664 SWANSON RIVER, GAS STORAGE 772803 1.37% SWANSON RIVER, GAS STORAGE 772805 98.63% 10. Pilot and Purge 483 11. Assist Gas 0 12. Fuel gas used in lease operations 37,217 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 643)' Includes Transferred 203,953 Lease Use MCF 15. NGL Gas Equivalent p Conservation MCF 16. Purchased gas -Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 81,902 Injected into Storage 86,061 Other 1570B 4,159 Transferred Gas used as Fuel: - 86,061 Storage Inv. 3,587,097 1 hereby certify that the foregoing is true and correct to the best of my knowledge. • . ,, 7� Note: All volumes must be corrected to Signature Dq-jz,L Title Production Analyst pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name Cortney Der Phone 713-289-2881 Date 6/30/2014 AAC25.235. Corrected OR FLARING EVENTS GREATER THAN 1 HOUR RptDate O No FacifityNo Date Flared Start Time Endin Time End Date Planned MCF Description of Flaring Event Action Taken to Minimize Volume Excess venting due to shutdown of Excess venting necessary until the cooler 05/01/2014 124250 1330000081 5/16/2014 8:00:00 AM 6:30:00 PM 05/16/14 P 16 Compressor K-22 for Scheduled could be cleaned and the compressor Maintenance to clean the cooler. could be brought back online. Excess venting due to a power Exces necessaryuntilower could outage which caused the 05/01/2014 124250 1330000081 05/31/14 11:15:00 AM 1159:00 PM 05/31/14 P 18 be restored and Compressor could be restored unavoidable shutdown of brought back online. om Cpressor K-22. Excess flaring necessary until power could Excessflaringduetoafacilitywide 05/01/2014 124250 1330000087 05/31/14 11:15:00 AM 11:59:00 PM 05/31/14 P 629 be restored and equipment brought hack shutdown cause by a power outage. online. I STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 1 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator I HILCORP ALASKA LLC 5. MonthfVear of Disposition I May 2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 77,120 Pool Name Pool Code Percent 7. Reinjected" Includes Transferred Gas. See Remarks 88,595 8. Flared or vented 1 hour or less 22 9. Flared or vented more than 1 hour (see IrlStr.) 666 SWANSON RIVER, GAS STORAGE 772803 1.37% SWANSON RIVER, GAS STORAGE 772805 98.63% 10. Pilot and Purge 486 11. Assist Gas 0 12. Fuel gas used in lease operations 37,412 13. Other (see instructions) 0 Official Use Only Authorization >1 hr Safety � � C, D MCF 14. TOTAL VOLUME (ITEMS 6.13) " Includes Transferred 204,303 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 . Z 6 -( y 18. Transferred to: 0 C15mmissioner Date 19. Remarks: Transferred From Swanson River Field Other 1570B 84,561 4,034 88,595 Injected into Storage 88,595 Transferred Gas used as Fuel: - Storage Inv. 3,587,097 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature "`�L Dyi�. Title Production Analyst I Note: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Dyer Phone 713-289-2881 Date 6/20/2014 VL -F Vzz,)JF OR FLARING EVENTS GREATER THAN 1 HOUR 0 No Fadii No Date Ftared Start Time Endin Time End Date Planned MCF Descriof Fladn Event Action Taken to Minimtre Volume Excess venting due to shutdown of Excess venting necessary until the cooler 124250 1330000081 5/16/2014 8:00:00 AM 6:30:00 PM 05/16/14 P 16 Compressor K-22 for Scheduled could be cleaned and the compressor could FRMe Maintenance to clean the cooler. be brought back online. Excess venting due to a power outage Excess venting necessary until power could 124250 1330000081 05/31/14 11:15:00 AM 11:59:00 PM 05/31/14 P 18 which caused the unavoidable be restored and Compressor could be shutdown of Compressor K-22. brought back online. Excess flaring necessary until power could to a facility wide Excessshutdown 05/07/2074 724250 7330000081 OS/3U34 11:15:00 AM 11:59:00 PM 05/31/14 P 633 j be restored and equipment brought back e b shutdown cause by a power outage. n cause online. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4.Operator HILCORP ALASKA LLC 5. MonthfYear of Disposition I June 2014 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 0 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 172,008 8. Flared or vented 1 hour or less 217 9. Flared or vented more than 1 hour (see instr.) 769 SWANSON RIVER, GAS STORAGE 772803 0.00% SWANSON RIVER, GAS STORAGE 772805 100.00% 10. Pilot and Purge 489 11. Assist Gas 0 12. Fuel gas used in lease operations 30,144 13. Other (see instructions) 0 Official Use Only Authorization >1 he Safety -f�q -7 I MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 203,627 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Wase: MCF 17. Transferred from: (Off -lease Gas) 0._ 1-3 _/ 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field Other 15706 178,308 7,744 186,052 Injected into Storage 172,008 Transferred Gas used as Fuel: 14,044 Storage Inv. 3,678,081 1 hereby certify that the foregoing is true and correct to the best of my knowledge. �--ff ,���� 7-1 Signature -wr"r�L Dl ' Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Dyer Phone 713-289-2881 Date 71M2014 ✓LF- Y/�S)!i- OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDate 0 No FacilityNo Date Flared Start Time Ending Time End Date Planned MCF Description of Flanno Event Volume Excess venting necessary until Excess venting due to a power outage Power could restored and 06/01/2014 124250 1330000081 06/01/2014 12:00:00 AM 6:30:00 PM 06/02/14 U 51 which caused the unavoidable C°mpresso coouu ld be brought shutdown of Compressor K-22. hack online. ba Excess venting necessary until a Excess venting due to unavoidable 06/01/2014 124250 1330000081 06/03/2014 02:00:00 PM 3:25:00 PM 06/03/14 U 2 shutdown of Compressor K-caused new throttle rod could be installed and compressor by a broken throttle roo d. restarted. Excess venting due to scheduled Excess venting necessary until preventative maintenance on preventative maintenance 06101/2014 124250 1330000081 06/05/2014 07:30:00 AM 9:15:00 PM 06/05/14 P 2 Compressor K-22 for an oil and filter could be completed and change. compressor restarted. Excess venting necessary until Excess venting due to a power outage power could be restored and 06/01/2014 124250 1330000081 06/1612014 4:15:00 PM 11:00:00 PM 06/16/14 U fi which caused the unavoidable Compressor could be brought shutdown of Compressor K-22. back online. Excess flaring due to unscheduled Excess flaring necessary until 06/01/2014 124250 1330000081 06/17/2014 4:00:00 AM 6:45:00 PM 06/21/14 U 675 maintenance on Compressor K-8 for the cause of the leak could be repair of a gas leak on the suction identified and repaired. scrubber. Excess venting necessary until Excess venting due to Compressor K-8 maintenance could be 06/01/2014 124250 1330000081 0621/2014 12:05:00 AM 6:05:00 PM 06/21/14 U 25 scrubber bottle failure and overload performed. The scrubber bottle of Compressor K-22. on Compressor K-8 was replaced. Excess flaring necessary until Excess flaring due to unavoidable pressure could be normalized 06/01/2014 124250 1330000081 06/24/2014 11:15:00 AM 12:45:00 PM 06/24/14 U 8 shutdown of Compressor K-8 due to and compressor brought back high 11150 Flare pressure. online. �r � STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION RECEIVE® AUG 2 2 2014 A®GCC 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator5. HILCORP ALASKA LLC MonthlYear of Disposition Jul 2014 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total volume. 6. Sold 71,537 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 45,800 8. Flared or vented 1 hour or less 111 9. Flared or vented more than 1 hour (see inStf.) 7 SWANSON RIVER, GAS STORAGE 772803 3.83% SWANSON RIVER, GAS STORAGE 772805 96.17% 10. Pilot and Purge 515 11. Assist Gas 0 12. Fuel gas used in lease operations 43,308 13. Other (see instructions) 0 Official Use Only Authorization >1 hr Safety g l MCF 14. TOTAL VOLUME (ITEMS 6-73)' Includes Transferred 161,278 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas -Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 45,255 Injected into Storage 45,800 Other 1570B 545 Transferred Gas used as Fuel: - 45,800 Storage Inv. 3,625,978 1 hereby certify that the foregoing is true and correct to the best of my knowledge. 7-� Signature �'^"""� Dom' Title Production Analyst ote: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 r1AC25.235. Printed Name Cortne Der Phone 713-289-2881 Date 8/20/2014 AUG 2 2 2014 n3A OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize Facili No Date Flared Start Time EndingTime End Date Planned MCF Description of Flaring Event Volume R tDater124250 Excess venting necessary until Excess venting due to a power outage power could be restored and 06/01/2014 1330000081 06/01/2014 12:00:00 AM 6:30:00 PM 06/02/14 U 51 which caused the unavoidable Compressor could be brought shutdown of Compressor K-22. back online. Excess venting necessary until a Excess venting due to unavoidable new throttle rod could be 06/01/2014 124250 1330000081 06/03/2014 02:00:00 PM 3:25:00 PM 06/03/14 U 2 shutdown of Compressor K-22 caused installed and compressor by a broken throttle rod. restarted. Excess venting due to scheduled Excess venting necessary until preventative maintenance on preventative maintenance 06/01/2014 124250 1330000081 06/05/2014 07:30:00 AM 9:15:00 PM 06/05/14 P 2 Compressor K-22 for an oil and filter could be completed and change. compressor restarted. Excess venting necessary until Excess venting due to a power outage power could be restored and 06/01/2014 124250 1330000081 06/16/2014 4:15:00 PM 11:00:00 PM 06/16/14 U 6 which caused the unavoidable Compressor could be brought shutdown of Compressor K-22. back online. Excess flaring due to unscheduled Excess flaring necessary until 06/21/14 U 675 maintenance on Compressor K-8 for the rause of the leak could berepair 06/01/2014 124250 1330000081 06/17/2014 4:00:00 AM 6:45:00 PM of a gas leak on the suction identified and repaired. scrubber. Excess venting necessary until Excess venting due to Compressor K-8 maintenance could be 06/01/2014 124250 1330000081 06/21/2014 12:05:00 AM 6:05:00 PM 06/21/14 U 25 scrubber bottle failure and overload performed. The scrubber bottle of Compressor K-22. on Compressor K-8 was replaced. Excess flaring necessary until Excess flaring due to unavoidable pressure could be normalized 06/01/2014 124250 1330000081 06/24/2014 11:15:00 AM 12:45:00 PM 06/24/14 U 8 shutdown of Compressor K-8 due to and compressor brought back high #150 Flare pressure. online. 3cc STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION RECEIVED SEP 19 2014 AOGCC 1. Facility Number 1330000081 2. Facility Name Swanson River Stora a 3. Field Swanson River Unit 4. Operator5. HILCORP ALASKA LLC MonthNear of Disposition Au ust 2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 95,160 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 64,064 8. Flared or vented 1 hour or less 35 9. Flared or vented more than 1 hour (see instr.) 162 SWANSON RIVER, GAS STORAGE 772803 0.50% SWANSON RIVER, GAS STORAGE 772805 99.50% 10. Pilot and Purge 637 11. Assist Gas 0 12. Fuel gas used in lease operations 40,647 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety Z- MCF 14. TOTAL VOLUME (ITEMS 6.13). Includes Transferred 200,705 Lease Use MCF 15, NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: JMCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field Other 1570B 63,409 655 64,064 Injected into Storage 64,064 Transferred Gas used as Fuel: - Storage Inv. 3,552,994 1 hereby certify that the foregoing is true and correct to the best of my knowledge. • .� ,, 7-� Signature/ Dy�.z- Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 9/20/2014 f �i �I13- OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDate O NoFacilitvNo Date Flared Start Time Ending Time End Date Planned MCF Description of Flanno Event Volume Excess venting due to unscheduled Excess venting necessary until 08/01/2014 124250 1330000081 8/2/2014 5:00:00 PM 11:59:00 PM 8/2/2014 N 11.7 shutdown of Compressor K-22 compressor could be restarted because of low suction. and brought back online. Excess venting due to unscheduled Excess venting necessary until 08/01/2014 124250 1330000081 8/4/2014 11:00:00 AM 12:30:00 PM 8/4/2014 N 2.5 shutdown of Compressor K-22 because of high tank vapors in Tank compressor could be restarted and brought back online. 22. venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/5/2014 5:30:00 PM 6:45:00 PM 8/5/2014 N[27temperature shutdown of the compressor cooled and mpressor K-22. restarted. Excess venting necessary until Excess venting due to unscheduled the mechanic could address the 08/01/2014 124250 1330000081 8/7/2014 1:30:00 PM 11:59:00 PM 8/7/2014 N 17.5 shutdown of Compressor K-22. work order. Compressor was Compressor would not stay running. repaired and restarted. Excess venting necessary until Excess venting due to unscheduled the mechanic could address the 08/01/2014 124250 1330000081 8/8/2014 12:01:00 AM 7:00:00 AM 8/8/2014 N 11.7 shutdown of Compressor K-22. work order. Compressor was repaired and restarted. Excess venting due to unscheduled Excess venting necessary until 08/01/2014 124250 1330000081 8/17/2014 10:00:00 AM 11:30:00 AM 8/17/2014 N 2,5 shutdown h Compressor Tank because of high vapors from Tank 22 compressor could be loaded and restarted. which overloaded the compressor. Excess venting due to well liquids Excess venting necessary until 08/01/2014 124250 1330000081 8/19/2014 11:00:00 AM 3:00:00 PM 8/19/2014 Y 6.7 unloading causing over pressurization pressure could be relieved and In the field. liquids unloaded from wells. Excess venting due to shutdown of Excess venting necessary until 08/01/2014 124250 1330000081 8/21/2014 2:00:00 PM 7:15:00 PM 8/21/2014 N 8.7 Compressor K-22 because of high the compressor cooled and temperature alarms. restarted. 611I WE x 951 YA RECEIVED c'P 19 2014 7,� OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDate O No I FacilityNo Date Flared Start Time Endmo Time End Date Planned MCF Description of Flaring Event Volume Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/22/2014 12:00:00 PM 4:30:00 PM 8/22/2014 N 7.5 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/23/2014 3:00:00 PM 4:30:00 PM 8/23/2014 N 2.5 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/24/2014 12:00:00 PM 2:30:00 PM 8/24/2014 N 4.2 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/25/2014 12:00:00 PM 4:45:00 PM 8/25/2014 N 7.9 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to unscheduled Excess venting necessary until 08/01/2014 124250 1330000081 8/26/2014 6:15:00 AM 11:59:00 PM 8/26/2014 N 29.6 shutdown of Compressor K-22 caused by valve trouble and valve cover valve issues could be resolved and compressor brought back replacement. online. Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/27/2014 12:00:00 PM 10:00:00 PM 8/27/2014 N 16.7 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/28/2014 5:00:00 PM 8:30:00 PM 8/28/2014 N 5.8 temperature and low suction the compressor cooled and shutdown of Compressor K-22. restarted. Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/29/2014 12:00:00 PM 7:30:00 PM 8/29/2014 N 12.5 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to high Excess venting necessary until 08/01/2014 124250 1330000081 8/30/2014 11:15:00 AM 6:30:00 PM 8/30/2014 N 12.1 temperature shutdown of the compressor cooled and Compressor K-22. restarted. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION PRODUCED CAS rveencmnN RECEIVED OCT 2 1 2014 �nM ;r_r 1. Facility Number 2. Facility Name r^V �r 1330000081 Swanson River Storage Disposition 3.` Field %q V Swanson Volume MCF 4. Operator 5. Month/Year of Disposition River Unit HILCORP ALASKA LLC September 2014 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume, 6. Sold 88,967 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Ga4. See Remarks 81,215 8. Flared or vented 1 hour or less 392 9. Flared or vented more than 1 hour (see instr.) 7 SWANSON RIVER, GAS STORAGE 772803 SWANSON RIVER, GAS STORAGE 772805 98.898.89 % 10. Pilot and Purge 465 11. Assist Gas 0 12. Fuel gas used in lease operations 39,187 13. Other (see instructions) 0 - Official Use ON Authorization >1 hr Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 210,233 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Wa—ste 1 MCF 17. Transferred from: (Off -lease Gas) 0 p 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 80,357 Injected into Storage 64,064 Other 15708 858 Transferred Gas used as Fuel: 17,151 81,215 Storage Inv. 3,552,994 1 hereby certify that the foregoing Is rue and correct to the best of my knowledge. „an' Signaturey—Title Production Analyst Nl volumesmust be corrected to sure of 14.65 psia and to a rature of 60o F. Authority 20 C25.235. Printed Name Cortne Der Phone 713-289-2881 Date 1012012014AX I/L 1012.00 RECEIVED nr; 21 2014 OR FLARING EVENTS GREATER THAN 1 HOUR - Action Taken to Minimize R tDate O No FacilftyNo, Date Flared Start Time Ending Time End Date Planned MCF Descrififion of Flaring Event Volume Excess venting due to unscheduled Excess venting necessary until 09/01/2014 124250 1330000081 9/2/2014 6':45:00 AM 9:30:00 AM 9/2/2014 N 4 7 shutdown of Compressor K-22 caused by increased tank vapors due to wells compressor rpms could be increased and compressor being brought online. restarted. 09/01/2014 124250 1330000081 9/23/2014 2:15:00 PM 3:45:00 PM 9/23/2014 N 2.3 Excess venting due to unscheduled shutdown of Compressor K-22 due to high discharge pressure from shutdown of Compressor K-8. Excess venting necessary until both Com pressor K-8 and K-22 p could be restarted. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION cnru !Tv pEpORT nP oRnnl riven r.AR nimPOSITION 1. Facility Number 1330000081 2. Facility Name Swanson River Storage 3. Field Swanson River Unit 4. Operator HILCORP ALASKA LLC 5. MonlhfVear of Disposifion October 2014 Disposition Volume MCF 20. Forproduction from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 309,730 Pool Name Pool Code Percent 7. Reinjected- Includes Transferred Gas. See Remarks 27,111 8. Flared or vented 1 hour or less 24 9. Flared or vented more than 1 hour (see instr.) 784 SWANSON RIVER, GAS STORAGE 772803 41.44% SWANSON RIVER, GAS STORAGE 772805 58.56% 10. Pilot and Purge 55 11. Assist Gas 0 12. Fuel gas used in lease operations 4,038 13. Other (see instructions) 0 Official Use Only Authorization >1 hr: Safety —17 MCF 14. TOTAL VOLUME (ITEMS 6.13) ` Includes Transferred 341,142 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field 27,111 Injected into Storage 27,111 Other 15708 0 Transferred Gas used as Fuel: - 27,111 Storage Inv. 3,394,400 I hereby certify that the foregoing is true and correct to the best of my knowledge. ////?� Signature li'�'Qu I/L/fr/L Title Production Analyst Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Dyer Phone 713-289-2881 Date 11117120141 )/rt— 1 ZJ191 j* OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDater124250 Facili No Date Flared Start Time EncinoTime End Date Planned MCF Descd tion of Flaring Event Volume Excess flaring necessary until 10/01/2014 1330000081 10/9/2014 12:01:00 AM 10/9/2014 4:00:00 AM N 8.S Excess flaring due to valve on open valve could be located flan vessel left open and gas sent to flare. and closed. Excess venting due to high Excess venting necessary until 10/01/2014 124250 1330000081 10/10/2014 3:30:00 PM 10/10/2014 4:45:00 PM N 0.2 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess flaring necessary until Excess flaring due to a facility wide power could be restored and 10/01/2014 124250 1330000081 10/11/2014 8:00:00 AM 10/11/2014 4:00:00 PM N 79.5 shutdown cause by a power outage. equipment brought back online. Excess flaring necessary until Excess flaring due to a facility wide power could be restored and 10/01/2014 124250 1330000081 10/11/2014 8:00:00 AM 10/11/2014 4:00:00 PM N 3.2 shutdown cause by a power outage. equipment brought back online. Excess flaring necessary until Excess flaring due to a facility wide power could be restored and 10101/2014 724250 1330000081 10/11/2014 8:00:00 AM 10/11/2014 4:00:00 PM N 6.7 shutdown cause by a power outage. equipment brought back online. Excess venting necessary until Excess venting due to a power outage power could he restored and 10/01/2014 124250 1330000081 10/11/2014 8:00:00 AM 10/11/2014 4:00:00 PM N 1.3 which caused the unavoidable Compressor could be brought shutdown of Compressor K-22. hack online. Excess flaring due to high production Excess flaring necessary until 10/01/2014 124250 1330000081 10/14/2014 8:30:00 AM 10/14/2014 10:30:00 PM N 0.1 which caused an production slowed down and overload/overpressurization of compressor able to handle gas. Compressor K-8. Excess venting due to high production Excess venting necessary until 10/01/2014 124250 1330000081 10/14/2014 12:00:00 PM 10/14/2014 7:45:00 PM N 1.3 which caused an production slowed down and overload/overpressurization of compressor able to handle gas. Compressor K-22. Action Taken to Minimize R 1Date O No I FacilitVNo Date Flared Start Time Ending Time End Date Planned MCF Description of Flanng Event Volume Excess venting due to high production Excess venting necessary until 70!07/2014 124250 7330000081 10/15/2014 4:00:00 AM 10/15/2014 10:45:00 AM N 1.1 which caused an overload/overpressurizization of production slowed down and compressor able to handle gas. Compressor K-22. Excess venting due to high Excess venting necessary until 10/01/2014 124250 1330000081 10/17/2014 1:30:00 AM 10/17/2014 3:00:00 PM N 0.2 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to high production Excess venting necessary until 10/01/2014 124250 1330000081 10/19/2014 12:00:00 PM 10/19/2014 2:00:00 PM N 0.3 which caused an overload/overpressurization and high production slowed down and compressor able to handle gas. temperatures on Compressor K-22. Excess flaring due to unscheduled maintenance on Compressor K-8 caused by lose if #2 Comp. Cylinder Excess flaring necessary until 10/01/2014 124250 1330000081 10/22/2014 2:00:00 AM 10/28/2014 1:00:00 PM N 79.0 piston liner. Parts are on order and parts arrive and Compressor K - are scheduled to arrive on November 8 can be repaired. 3. Until parts arrive, Compressor K-8 will flare continuously. Excess venting due to unscheduled Excess venting necessary until 10/01/2014 124250 7330000081 10/22/2014 12:00:00 PM 10/22/2014 6:00:00 PM N 1.0 shutdown of Compressor K-22 due to bath Compressor K-22 could be high discharge pressure from shutdown of Compressor K-8. restarted. due to high Excess venting necessary until 10/01/2014 124250 1330000081 10/28/2014 3:30:00 AM 10/28/2014 5:00:00 PM N 0.2 =E.cessnting ture shutdown of the compressor cooled and pressor K-22. restarted. Excess venting due to high Excess venting necessary until 10/01/2014 124250 1330000081 10/29/2014 9:15:00 AM 10/29/2014 11:00:00 AM N 0.3 temperature shutdown of the compressor cooled and. Compressor K-22. restarted. Excess venting necessary until Excess venting due to unscheduled compressor could be loaded 10/01/2014 124250 1330000081 10/31/2014 9:15:00 AM 10/31/2014 3:45:00 PM N 1.1 shutdown of Compressor K-22 due to and restarted, line was swept high discharge pressure. and pumped with Methanol. STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACII. ITV REPORT OF PRODUCED GAS DISPOSITION DEC 2 4 2014 A®GCC 1. Facility Number 1330000081 2. FacilityName Swanson River Stora a 3. Field Swanson River Unit 4. Operator HILCORP ALASKA LLC 5. MonthfVear of Disposition November 2014 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold 82,421 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 32,529 8. Flared or vented 1 hour or less 4 9. Flared or vented more than 1 hour (see instr.) 27 SWANSON RIVER, GAS STORAGE 772803 9.99% SWANSON RIVER, GAS STORAGE 772805 90.01% 10. Pilot and Purge 59 11. Assist Gas 0 12. Fuel gas used in lease operations 3,386 13. Other (see instructions) 0 Official Use Only Authorization >1 hr. Safety 2 MCF 14. TOTAL VOLUME (ITEMS 6.13)' Includes Transferred 118,426 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation MCF 16. Purchased gas - Transferred from SRF 0 Waste: MCF 17. Transferred from: (Off -lease Gas) 0 3 • 2-3 — / 3 18. Transferred to: 0 Commissioner Date 19. Remarks: Transferred From Swanson River Field Other 1570B 32,475 54 32,529 Injected into Storage 32,529 Transferred Gas used as Fuel: - Storage Inv. 3,164,900 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature F/L/9/L Title Production Analyst INote: All volumes must be corrected to pressure of 14.65 psis and to a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Der Phone 713-289-2881 Date 12/12/2014 ✓TL- 3/IR f !S ..u1, ;C OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize RiptDate O No FacilityNo Date Flared Start Time Ending Time End Date Planned MCF Description of Flaring Event Volume Excess venting necessary until Excess venting due to plugging of a cutting box was set up to 11/01/2014 124250 1330000081 11/1/2014 12:01:00 AM 6:30:00 PM 11/1/2014 U 2.5 the discharge line on Compressor K- 22 a high blow the line into and causing pressure compressor brought back shutdown. online. Excess venting due to unscheduled Excess venting necessary until 11/01/2014 124250 1330000081 11/2/2014 12:30:00 AM 7:00:00 AM 11/2/2014 U 0.9 shutdown of Compressor K-22 caused by high discharge. Line was Compressor K-22 could be brought back online. blown down to cutting box. Excess venting due to Excess venting due to unscheduled unschd shutdown of 17/01/2014 124250 1330000081 11/3/2014 8:30:00 AM 9:45:00 AM 11/3/2014 U 0.2 shutdown of Compressor K-22 K-2because Compressor K-22 because of Compressor because of high discharge pressure. high discharge pressure. Excess venting due to high Excess venting necessary until 11/01/2014 124250 1330000081 11/5/2014 8:15:OOAM 9:30:00 AM 11/5/2014 U 0.2 temperature shutdown of the compressor cooled and Compressor K-22. restarted. Excess venting due to unscheduled Excess venting necessary until 11/01/2014 124250 1330000081 11/10/2014 8:30:00 PM 11:30:00 PM 11/10/2014 U 0.4 shutdown of Compressor K-22 because of high vapors from Tank 22 compressor could be loaded and restarted. which overloaded the compressor. Excess venting necessary until Excess venting due to unscheduled parts can be ordered and 11/01/2014 124250 1330000081 11/16/2014 5:45:00 AM 6:00:00 PM 11/20/2014 U 14.4 shutdown of Cumressor K-22 caused by lost of the #2 Compressor shipment arrived. Compressor is expected to be down for Cylinder. about 3 more days. Excess venting due to a power Excess venting necessary until outage which caused the power could be restored and 11/01/2014 124250 1330000081 11/18/2014 12:45:00 PM 8:45:00 PM 11/18/2014 U 7.6 unavoidable shutdown of Compressor could be brought Compressor K-8. back online. Excess venting necessary until Excess venting due to scheduled maintenance could be 11/01/2014 124250 1330000081 11/21/2014 6:00:00 AM 9:00:00 AM 11/21/2014 P 0.4 maintenance on Compressor K-22 to complete and compressor replace the valves on Cylinder#1. brought back online. Excess venting necessary until Excess venting due to the 20V1 an indirect heater and steam 11/01/2014 124250 1330000081 11/25/2014 6:00:00 AM 10:30:00AM 11/25/2014 U 0.6 instruair lines freezing off whichh taus caused an unscheduled could be used on the air lines and line unfrozen. Compressor shutdown of Compressor K-22. loaded and restarted. ;C STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PROOIICFD OAS DISPOSITION 1. Facility Number 1330000081 2. Facility Name S%vanson River Stora a 3. Field Swanson River Unit 4. Operator HILCORP ALASKA LLC 5. Month/Year of Disposition December 2014 Disposition Volume MCF 20. For production from multiple pools, list contnbution of each pool as a percent of Total Volume. 6. Sold 98,839 Pool Name Pool Code Percent 7. Reinjected' Includes Transferred Gas. See Remarks 51,650 8. Flared or vented 1 hour or less 6 9. Flared or vented more than 1 hour (see instr.) 56 SWANSON RIVER, GAS STORAGE 772803 1.11% SWANSON RIVER, GAS STORAGE 772805 98.89% 10. Pilot and Purge 102 11. Assist Gas 0 12. Fuel gas used in lease operations 4,155 13. Other (see instructions) 0 Official Use Only Authorization>1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13)' Includes Transferred 154,808 Lease Use MCF 15. NGL Gas Equivalent 0 Conservation / to MCF 16. Purchased gas -Transferred from SRF 0 Waste: JMCF 17. Transferred from: (Off -lease Gas) 0 18. Transferred to: 0 Commissioner Date 19, Remarks: Transferred From Swanson River Field Other 15706 51,650 0 51,650 Injected into Storage 51,650 Transferred Gas used as Fuel: - Storage Inv. 3,164,900 1 hereby certify that the foregoing is true and correct to the best of my knowledge. Signature DNS, l.� Title Production Analyst Note: All volumes must is corrected to pressure off 60o psis and it a temperature of 60o F. Authority 20 AAC25.235. Printed Name Cortney Dyer Phone 713-289-2881 Date 1/19/2015 yTL Zl��ys OR FLARING EVENTS GREATER THAN 1 HOUR Action Taken to Minimize R tDate O No Facilityi Date Flared Start Time Ending Time End Date Planned MCF Description of Flaring Event Volume Excess venting due to scheduled Excess venting necessary a mil 12/01/2014 124250 1330000081 12/19/2014 4:00:00 PM 8:00:00 PM 12/19/2014 P 2.1 maintenance to depressurize the maintenance could be back side of the ESP. complete. Excess venting due to blow down of Well 148-27 while performing a flow Excess venting necessary until 12/01/2014 124250 1330000061 12/20/2014 12:00:00 AM 11:59:00 PM 12/22/2014 P 39'4 test. Venting from the back side flow testing can be completed. casing to a Johnson tank. Excess venting due to scheduled Excess venting necessary until maintenance on Compressor K-22 to maintenance could be 12/01/2014 124250 1330000081 12/21/2014 12:00:00 PM 2:45:00 PM 12/21/2014 P 0.4 change the oil and filters, replace completed and compressor spark plugs, and adjuste lube rates. restarted. Excess venting necessary until Excess venting due to unscheduled spare parts can be ordered and 12/01/2014 124250 1330000081 12/23/2014 4:15:OOAM 11:59:00 PM 12/26/2014 U 14.0 maintenance on Compressor K-22 received by the facility and due to loss of a cylinder. repairs could be made.