Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation Commission
Loading...
HomeMy WebLinkAboutSwanson River / Unocal
STATE OF ALASKA
AOGCC
GAS DISPOSITION FILES
YEAR: 2002
FACILITY: SR Swanson River LEX
OPERATOR: UNION OIL CO OF
CALIFORNIA
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
January 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 0
2. Reinjected 134,429
./
3. Flared or vented less than 1 hour 2,079
4. Flared or vented greater than 1 hour 340
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,085
6. Used for lease operations . 158,534
7. *Other (Shrinkage) 22,087
TOTAL items 1-7 318,554
8. NGL gas equivalent produced 0
9. Purchased gas 1,280,684
10. Transferred from: 0
11. Transferred to: 0
Remarks:
1 hereby certlIY that the toJomg IS true ana correct to the Dest 01 my Knowledge.
Signature: déLø :J~f!t~ Title: Acct. Super. Date: 19-Feb-02
tI
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 94.56%
Undefined 772100 0.52%
Undefined 772500 4.92%
.
Official Use Only - Flaring Authorization> 1 hr.
1. Safety MCF
2. Lease Use 3/0 MCF
3. Conserv. Purposes MCF
G/~ O~¿U· ~ :sId
ð#-
,
Commiss@er Date
,
IT; ¡r ~ql~ "'>_1 ~ <;-'11 I
. ...
Note: All volumes must be corrected to pressure
of 14.65 psia and to a temperature of 60 degrees F.
Report due by tl1e 20th of the month following the
month of disposition.
Authority 20 AAC 25.235.
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthlY ear:
January 2002
Date & Time Event Gas Steps Taken to Equipment Down
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence Mp-2 ID Number
1/8102 9:00 1/8/02 10:30 321 N K-12 Shut down - fly wheel overspeed. SAFETY OTHER: SEE DESC OF EVEN Restarted the unit after and reload Continue to monitor the suction S-RCP-DCOK012
the compressor pressure into the compressor
1/31/026:50 1/31/028:30 19 N Planned Maintanince on K-8 SAFETY OTHER: SEE DESC OF EVEN Finished with the planned services, Had necessary materials and S-RCP-WAOK08
started and reloaded the equipment on hand to prefonn
compressor servies as necessary.
.
,
,
Report Date: 2/12/02
Page: 1 of 1
'4
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
February 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 0
2. Reinjected 127,721
3. Flared or vented less than 1 hour 3,047
4. Flared or vented greater than 1 hour 40 ---
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 980
6. Used for lease operations 141,171
7. *Other (Shrinkage) 21,739
TOTAL items 1-7 294,698 ,/'
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 1,131,754
10. Transferred from: 0
11. Transferred to: 0
Remarks:
1 hereby certl/~~",e toa:l~ IS. true and correct to the best 01 my knowledge.
Signature: ' ß #'j. If (L#? Title: Acct. Super. Date: ll-Mar-02
~ IJ
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 89.95%
Undefined 772100 1.93%
Undefined 772500 8.12%
Official UseQnly - Flaring Authorization> 1 hr.
1. Safety tic MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
G~~j.t 3/.>.~~ ~
Commissi _ er Date
WGft-
1/ U/fll..
Note: All volumes must be corrected to pressure
of 14.65 psia and to a temperature of60 degrees F.
Report due by the 20th of the month following the
month of disposition.
Authority 20 AAC 25.235.
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthN ear:
February 2002
Date & Time Event Gas Steps Taken to Equipment Down
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence MP-2 ID Number
2/3/02 9:45 2/3/02 11 :30 40 Y K-B DOWN TO WORK ON SAFETY v' OTHER: SEE DESC OF EVENT Planned maintance with proper Repaired to maintain proper S-RCP-WAOK08
PRESSURE DRAIN equipment and personnel on hand operations of equipment.
to fix pressure drain on K-8
compressor. Reumed to normal
operations ASAP.
..
Report Date: 3/6/02
Page: 1 of 1
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
March 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 0
2. Reinjected 445,811
3. Flared or vented less than 1 hour 1,158
4. Flared or vented greater than 1 hour 266 /
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,085
6. Used for lease operations 154,739
..
7. *Other (Shrinkage) 26,326
TOTAL items 1-7 , 629,385 ,/
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 692,820
.
10. Transferred from: 0
11. Transferred to: 0
Remarks:
1 hereby cert~Jt the tor~mg IS true and correct to the best ot my IŒ.Owledge.
Signature: 1 ({, At q.. '1ll~./Í) Title: Acct. Super. Date: 12-Apr-02
¡ (j
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 94.49%
Undefined 772100 0.74%
Undefined 772500 4.77%
Official Use Only - Flaring Authorization> 1 hI.
1. Safety 2,(p(p MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
~~ Lj/~/, r
Date
uqk
'7 2002
A,_()iI&GasCOOI.Com~¡r
AndtOtage
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthlY ear:
March 2002
Date & Time Event Gas Steps Taken to Equipment Down
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence MP-2 ID Number
3/4102 15:00 3/410216:15 , 42 N Inlet filter LCV (level control valve) SAFETY OTHER: SEE DESC OF EVENT Shut in LCV to stop 9as flow, Reset LCV. S-SP-45#
opens, dumps gas to LP system. instrument technician resets
LCV. build level back up in tank,
and retum facility to normal
operation as soon as possible.
316102 10:30 316102 12:45 94 N K-8 shuts down for unknown SAFETY UNSCHEDULED MAINTENANCE Load and restart K-8. and retum Normal oil field operations. S-RCP-WAOK08
reasons. facility to normal operation as
soon as possible.
3/1910210:45 311910213:00 43 N Dump valve 9asses to LP system SAFETY OTHER: SEE DESC OF EVENT Shut In valve to stop 9as flow, Reset valve. S-SP-45#
instrument technician resets
valve, build level back up In tank,
and retum facility to normal
operation as soon as possible.
3/311024:30 3/311025:45 87.3 N K-8 shut down, frozen scrubber SAFETY OTHER: SEE DESC OF EVENT Thaw valve. load and restart K-8. Normal oil field operation. S-SP-45#
valve. and retum facility to normal
operation as soon as possible.
,.
,
"
Report Date: 4/10/02
Page: 1 of 1
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
April 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold , 0
2. Reinjected 312,717
3. Flared or vented less than 1 hour 597
4. Flared or vented greater than 1 hour 0
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,050
6. Used for lease operations 138,421
7. *Other (Shrinkage) 26,187
TOTAL items 1-7 478,972
8. NGL gas equivalent produced 0
.
9. Purchased gas - Rental Return Gas 871,808
10. Transferred from: 0
11. Transferred to: 0
Remarks:
I ~erebY certityãthe toregomg 2:;c;nd correct to the best.ot my knowledge.
SIgnature: LuCÞ-(:] Jt.k/ TItle: Acct. Super. Date: 13-May-02
f/ 1/
Form 10-422
Rev. 4/95
*Indicate-contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 90.85%
Undefined 772100 1.12%
Undefined 772500 8.03%
Official Use Only - Flaring Authorization> 1 hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
Note: All volumes must be correçted topre"~ltre
of14.65 psia and to a temfièr~iU(e·~£lt>W!¥eðsF.
Report due by the 20th oftbe.mònthÆóllowmg the
month of disposition. .
Authority 20 AAC 25.235. .'. . ..... .... .
..
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
Montl1lY ear of Disposition
May 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 0
2. Reinjected 139,766
3. Flared or vented less than 1 hour 1,548
4. Flared or vented greater than 1 hour 15 ,/
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,085
6. Used for lease operations 133,433
7.' *Otl1er (Shrinkage) 24,800
1l()1lJ\I-items 1-7 300,647
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 777,671
10. 1lransferred from: 0
11. 1lransferred to: 0
Remarks:
I hereby cert¡na~ llietorx;~ng IS true and correct to the best ot my knOWledge.
Signature: êcli'lO llJ./e 1litle: Acct. Super. Date: 17-Jun-02
7f Ii
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name' Code Percent
Hemlock 772100 92.39%
Undefined 772100 0.31 %
Undefined 772500 7.30%
,
()fficial Use Only - Flaring J\uthorization > 1 hr.
1. Safety iF)' MCF .J6
2. Lease Use MCF
3. Conserv. Purposes MCF
~.. i/'IOd-
CõiñiñiSskit.r 1t'
Date
13(2....
Note: All volumes must be corrected to pressure
of 14.65 psia and to a temperature of 60 degrees F.
Report due by the 20th of the month following the
month of disposition.
Autl10rity 20 AAC 25.235.
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthlYear:
Date & Time Event Gas Steps Taken to
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence
5/18/02 15:30 5/20/0216:00 15 N K-22 vapor recovery compressor down SAFETY OTHER: SEE DESC OF EVENT High levels of cottonwood and Maintenance.
for maintenance. dandelion pappus clogged gas
cooler, blockage removed and K-
22 brought back on-line as soon as
possible.
Report Date: 6/11/02
Page: 1 of 4
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlYear of Disposition
June 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 0
2. Reinjected 424,291
3. Flared or vented less than 1 hour 451
4. Flared or vented greater tl1an 1 hour 0
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,050
6. Used for lease operations 130,508
7. *Other (Shrinkage) 25,933
TOTAL items 1-7 582,233
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 434,875
10. Transferred from: 0
11. Transferred to: 0
Remarks:
1 hereby cerh~at the tore7):ng IS .true and correct to the best ot my knowledge.
Signature: I ¡JI) ..~ 11 ) / J¿ 1z, Title: Acct. Super. Date: 15-Jul-02
1/ ¡J
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 92.96%
Undefined 772100 0.40%
Undefined 772500 6.64%
Official Use Only - Flaring Authorization> 1 hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
Note: All volumes must be corrected to pressure
of 14.65 psi a and to a temperature of 60 degrees F.
Report due by the 20th of the month following the
month of disposition.
Authority 20 AAC 25.235.
..
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
July 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 0
2. Reinjected 168,962
3. Flared or vented less than 1 hour 914
4. Flared or vented greater than 1 hour 161
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,085
6. Used for lease operations 127,756
7. *Other (Shrinkage) 27,893
TOTAL items 1-7 326,771
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 594,969
10. Transferred from: 0
11. Transferred to: 0
Remarks:
I hereby certIt)r that the toregomg IS true and correct to the best ot my knowledge.
Signature: ¿26~. f} 2k¿~/ Title: Acct. Super. Date: 09-Aug-02
v
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 90.50%
Undefined 772100 0.43%
Undefined 772500 9.07%
Official Use Only - Flaring Authorization> 1 hr.
1. Safety I ~ ( MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
G,~(1,I,,,(, * '\ L ~/o-
Commissio~r Date
~¡Q..-
Note: All volumes must be corrected to pressure
of 14.65 psia and to a temperature of60 degrees F.
Report due by the 20th of the montl1 following the
month of disposition.
Authority 20 AAC 25.235.
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthNear:
July 2002
Date & Time Event Gas Steps Taken to Equipment Down
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence Mp-2 ID Number
7/21/02 15:50 7/21/0217:15 75 N K-15 compressor shut down due to SAFETY OTHER: SEE DESC OF EVENT Lube check valve on K-15 Normal oil field operations. S-SP-MAIN
lube failure causing the Lex plant to compressor was replaced the
shut down. previous day. Check valve air
locked causing shut down.
Mechanic on location Identified
problem, bled down line. and
loaded compressor. Retumed to
normal operations.
7/23/0212:00 7/23/0214:00 86 N 2 inch main flare control valve froze SAFETY OTHER: SEE DESC OF EVENT Operators closed upstream hand Normal oil field operations. S-SP-MAIN
open due to temperature of gas valve, allowed control valve to
stream. thaw and retumed to normal
operations.
Report Date: 8/19/02
Page: 1 of 1
ALASKA OIL AND GAS CONSERVATION COMMISSION
FACILITY REPORT OF PRODUCED GAS DISPOSITION
Facility Operator Field(s) MonthlY ear of Disposition
SWANSON RIVER UNIT UNOCAL ALASKA RESOURCES SWANSON RIVER UNIT AUGUST 2002
Disposition Volume MCF*
1. Sold 0
2. Reinj ected 32.643
3. Flared or vented less than 1 hour 475
4. Flared or vented greater than 1 hour 166 /
(Supplemental report reqnired - See 20 MC 25.235)
5. Pilot and Purge 1.085
6. Used for lease operations 124.732
7. Other 24.123
TOTAL items 1 - 7 183.224
8. NGL gas equivalent produced 0
9. Purchased gas 719.259
10. Transferred from: 0
11. Transferred to: 0
Remarks:
I hereby certity that the foregoing is true and correct to the best of my knowledge.
Signature /l4P91fJ~ Title ACCOUNTING SUPERVISOR Date 09/13/2002
If 1/
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
HEMLOCK 772100 72.75
UNDEFINED 772110 0.40
UNDEFINED (GAS) 772500 26.85
1111¡III.jlliilll¡lllltll,II~IIIII··III;:¡I:·II~..·:11····¡·¡:'Ii
1. Safety I 6<'- MCF ~
2. Lease Use MCF
3. Conserv. Purposes MCF
~..W; ~~ ~I ~(I() )...-
Commis . ner Date
ß--
Note: All volumes must be corrected to
pressure of 14.65 psia and to a temperature of
60 degrees F. Report due by the 20th of the
month following the month of disposition.
Authority 20 AAC 25.235
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthlY ear:
Date & Time Event Gas Steps Taken to
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence
8/21027:30 8/21029:30 55 N K-8 compressor down. SAFETY UNSCHEDULED MAINTENANCE Leaking nipple on water cooling Replace nipple.
system, dewater system, replace
nipple from parts in inventory,
retum to nonnal operations.
,..-- -"'~'"
81181020:15 81181022:00 111 N K-8 compressor shuts down on hight SAFETY OTHER: SEE DESC OF EVENT Drain liquids from system, restart Nonnal oil field operations.
liquid alarm. '-- unit, and retum to nonnal
? operations.
-'~.'
.
Report Date: 9/17/02
Page: 1 of 4
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
September 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 0
2. Reinjected 122,821
3. Flared or vented less tl1an 1 hour 966
4. Flared or vented greater than 1 hour 26 ,V
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,050
6. Used for lease operations 126,338
7. *Other (Shrinkage) 27,435
TOTAL items 1-7 278,636
8. NGL gas equivalent produced 0
,
9. Purchased gas - Rental Return Gas 608,819
10. Transferred from: 0
11. Transferred to: 0
Remarks:
1 hereby cert,;;t the torJ;mg IS true ana correct to the best ot my Knowleage.
Signature: ' U9 n.., / /~ L,) Title: Acct. Super. Date: 17-0ct-02
U V
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 83.55%
Undefined 772100 0.55%
Undefined 772500 9.07%
Undefined 772555 6.83%
OffiqialJ.JseQnly - Flatjµg Autl1orizåtion > 1 hr.
1. Safety
~MCF
2. Lease Use
MCF
3. Conserv. Purposes
MCF
J:1;r/o ~
Date
Note: All volumes must be corrected to pressure
of 14.65 psi a and to a temperature of 60 degrees F.
Report due by the 20th of the month following the
month of disposition.
Authority 20 AAC 25.235.
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthlY ear:
September 2002
Date & Time Event Gas Steps Taken to Equipment Down
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence MP-2 ID Number
9/1/2002 10:00 9/1/200211 :15 26 Y K-8 DOWN FOR MONTHLY SAFETY SCHEDULED MAINTENANCE START AND LOAD K-8AFTER S-RCP-WAOK08
SERVICE WORK SERVICE WORK
Report Date: 10/9/2002
Page: 1 of 1
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
October, 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 91,058
2. Reinjected 0
3. Flared or vented less than 1 hour 899
4. Flared or vented greater than 1 hour 126 ./
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,085
6. Used for lease operations 144,000
7. *Other (Shrinkage) 27,030
TOTAL items 1-7 264,198
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 1,172,422
10. Transferred from: 0
,
11. Transferred to: 0
Remarks:
TI1ereoy ceifi/J7! file Iöreg:~ IS .true at;l~ correct to the best ot my KnOWledge.
Signature: r (~; //J;.Q ~ ~ [.tkJ Title: Acct. Super. Date: 19-Nov-02
71 /
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 62.62%
Undefined 772100 0.41%
Undefined 772500 17.98%
Undefined 772555 18.99%
",
Qîficialt]se Only-,rlaringAuthorization > 1 hr.
1. Safety [ Z(.:. MCF bð
2. Lease Use MCF
3. Conserv. Purposes MCF
,
~~";ø&J.J,-ßir '1f~foY
Date
Commlssl er
f:ßr
Note: All volumes must be corrected to pressure
of 14.65 psi a and to a temperature of60 degrees F.
Report due by the 20th of the month following the
month of disposition.
Authority 20 AAC 25.235.
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthlY ear:
October 2002
Date & Time Event Gas Steps Taken to Equipment Down
Begin End MCF Planned? Description of Incident Category Reason Actions Taken Minimize Recurrence MP-2 ID Number
10/2120024:00 10/2120025:30 126 N GASSED THRU, 1-9, -POOL TRAP SAFETY OTHER: SEE DESC OF EVENT RE-ROUTED GAS FLOW S-SP-45#
Report Date: 11/7/2002
Page: 1 of 1
ALASKA OIL AND GAS CONSERVATION COMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlY ear of Disposition
November, 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
1. Sold 185,539
2. Reinjected 0
3. Flared or vented less than 1 hour 1,491
4. Flared or vented greater than 1 hour 0
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,050
6. Used for lease operations 159,029
7. *Other (Shrinkage) 28,183
TOTAL items 1-7 375,292
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 1,099,680
10. Transferred from: 0
11. Transferred to: 0
Remarks:
1 ~erebY certl177t/the lOregOj{,I_S .true ano correct to the Dest.ol my Knowledge.
SIgnature: /I/lltl·Q //üiI!J TJtle: Acct. Super. Date: 19-Dec-02
4 /J
Form 10-422
Rev. 4/95
*Indicate contribution of each pool to total.
Pool Name Code Percent
Hemlock 772100 61.41 %
Undefined 772100 0.32%
Undefined 772500 25.13%
Undefined 772555 13.15%
Official Œ¡e Only - Flaring Authorization> 1 hr.
1. Safety MCF
2. Lease Use MCF
3. Conserv. Purposes MCF
Commissioner Date
Note: All volumes must be corrected to pressure
of 14.65 psia and to a temperature of60 degrees F.
Report due by the 20th of the month following the
month of disposition.
Authority 20 AAC 25.235.
, .
ALASKA OIL AND GAS CONSERV ATIONCOMMISSION
PRODUCER'S REPORT OF GAS DISPOSITION
Facility
Operator
Unocal
Field(s)
SWANSON RIVER UNIT
MonthlYear of Disposition
December, 2002
SWANSON RIVER UNIT
Disposition Total Volumes MCF
¡
1. Sold 66',489
2. Reinjected }01
~
3. Flared or vented less tl1an 1 hour 3,993
4. Flared or vented greater than 1· hour 3,687. v
(Supplemental report required-See 20 AAC 25.235)
5. Pilot and Purge 1,085
6. Used for lease operations 164,332
..
7. *Other (Shrinkage) 25,030
TOTAL items 1-7 265,317
8. NGL gas equivalent produced 0
9. Purchased gas - Rental Return Gas 1,004,367
10. Transferred from: 0
11. Transferred to: 0
Remarks:
1 hereby certity that the toregomg IS true and correct to the best ot my knowledge.
Signature: ~ (""L Title: Acct. Super. Date: 13-Jan-03
Form 10-422
Rev. 4/95
.
*lndicate contribution of each pool to total.
Pool Name Code Perèent
Hemlock 772100 0.17%
Undefmed 772100 1.24%
Undefmed 772500 62.50%
Undefmed 772555 36.09%
Official Use Only - :Flaring Authorization > 1 hr.
e... ...
1. Safety .3 r {;C(j1 MCF :)3,
2. Lease Use MCF
3. Conserv . Purposes MCF
,
,
Ú~·~ d/tO/ö3
co~er. . .
Date
C-
Note: All volumes must be corrected to pressure
of 14.65 psia and to a temperature of 60 de~ees F.
Report due by the 20th of the month followmg tl1e
month of disposition.
Authority 20 AAC 25.235.
Excess Flare Log Report
Facility Name:
SWANSON RIVER UNIT
MonthlYear:
December 2002
Date & Time Event Gas Steps Taken to Equipment Down
Begin End MCF Planned? Description of Incident CateQorv Reason Actions Taken Minimize Recurrence MP-2 ID Number
12/15/2002 18:00 12/15/200220:45 1090 N Power outage. SAFETY OTHER: SEE DESC OF EVENT Power outage. Waited for power Power restored.
to be restored. Facility returned
10 normal operations. 1
12/16/2002 20:45 12/16/200223:45 1307 N POWER OUTAGE SAFETY ! OTHER: SEE DESC OF EVENT Power outage. Waited for power Power restored. 1
to be restored. Facility returned
to nonnal operations. 1
12/18/200219:40 12/1912002 2:25 780 N Plant down due to power outage. SAFETY OTHER: SEE DESC OF EVENT Wells shut-in due to power Power restored. S-SP-150#
outage. Return to noonnal
operations as soon as power
restored.
12/18/200219:40 12/19/20022:25 289 N Plant down due to power outage. SAFETY OTHER: SEE DESC OF EVENT Wells shut-in due to power Power restored. 1 S-SP-150#
outage. Return to noonnal
operations as soon as power
restored.
12/19/20020:01 12/19/20021:40 158 N Plant down due to power outage. SAFETY OTHER: SEE DESC OF EVENT Wells shut-in due to power Power restored. S-SP-150#
outage. Return to noonnal
operations as soon as power
restored.
12120/2002 9:30 12/20/2002 19:40 63 N Depressurized main flare line for OPERATIONAL OTHER: SEE DESC OF EVENT Depressurized main flare line to Perfonned maintenance on S-SP-MAlN
maintenance. I desolve an ice plug in the line. flare line.
Ice plug was removed and facility
returned to nonnal operations as
soon as possible.
Report Date: 1/21/2003