Alaska Logo
Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
Loading...
HomeMy WebLinkAboutW McArthur River / Forest Oil STATE OF ALASKA AOGCC GAS DISPOSITION FILES YEAR: 2002 FACILITY: W McArthur River OPERATOR: FOREST OIL CORP ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthN ear of Disposition West McArthur River Unit FOREST Oil CORPORATION West McArthur River Unit January-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- / See 20 MC 25.235) 323 5. Pilot and Purge 2,115 6. Used for lease operations 23,740 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety MCF TOTAL items 1~7 26,178 " 2. lease Use :; y:z, MCF ",-,I ~~_... 8. NGl gas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas 552 ~\""-I\"'" ~I}O y 10. Transferred from: WFU #1 4,812 ~.du.L :\ti.À Q,¡ 11. Transferred to: 0 CommistiPner Q Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. OIL ¡.,JGÁ- z.¡ 1..5/ t) z... I hereby certify that the foregoing is true and correct to the best of my Note: All volumes must be corrected to pressure of knowledge. 14.65 psia and to a temperature of 60T Report due by the 20th of the month following the month in question. Signatur~ <í. ~ Authority 20 AAC 25.235 Title Production ManaQer Date: 02/12/02 Form 10-422 Rev 04/00 Forest Oil Corporation Excess Fla re Log "r o 'i CD (JJ rt' o .... ""'" Facility Name West McArthur Production Facility Date & Time Event Gas Steps Taken to Begin End MCF Planned Description of Incident Category Reason Action s Taken Minimize Recurrence Equipment 1/5/2002 1/5/02 COMPRESSOR SHUT REPLACE 7AM 5PM 230 Y DOWN N MAl NT. COUPLINGS PROPER MAINT. 1/6/02 1/6/02 COMPRESSOR SHUT 10:00AM 10:30AM 12 Y DOWN N MAINT. ADD PLUG N 1/7/02 1/7/02 COMPRESSOR SHUT 11:00AM 11 :30AM 12 Y DOWN N MAINT. ADDi PLUG N CHANGE 1/30/02 1/30/02 COMPRESSOR SHUT SEPARATOR 10: OOAM 1: 00 PM 69 Y DOWN N MAINT. FrL TER PROPER MAINT. > ""'" ¡II (JJ :;J=;' ¡II N "- N OJ "- N o o N CD 01 (¡J '0 > o ['T1 N "- (¡J CD o ....¡ N 01 CD I CD OJ o i-' Flare_log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthNear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit February-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent . 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- ./ See 20 MC 25.235) 46 5. Pilot and PurQe 1,743 6. Used for lease operations 18,239 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety MCF TOTAL items 1-7 20,028 ../ 2. Lease Use 1/.fC;. MCF 8. NGL gas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased Qas 500 (ßMA.. D'P¡vl(~ 4>,~ /0.J-- 10. Transferred from: WFU #1 1,212 11. Transferred to: 0 commis~ner 0 Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my Note: All volumes must be corrected to pressure of knowledge. 14.65 psia and to a temperature of 60'F. Report due by the 20th of the month following the month in question. ~ ~ ./~~ Title Production ManaQer Authority 20 AAC 25.235 Signatu .. Date: 03/08/02 tæA- '3ìz.z-lo L Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log Facility Name West McArthur Production Facility Date & Time Event Gas Steps Taken to Beç.¡in End MCF Planned Description of Incident Cateç.¡orv Reason Actions Taken Minimize Recurrence EauiDment . LOW GAS VOLUME INCREASE GAS BUILD UP LEVEL IN 12:30PM 2:30PM COMPRESSOR SHUT DUE TO #5 WELL VOLUME IN 1200 1200 BBL TANK IN 2/22/02 2/22/02 46 N DOWN N MAINT. BBL TANK ADVANCE OF MAINT. N -~ Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthlYear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit March-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- / See 20 MC 25.235) 2,346 5. Pilot and Purge 2,123 6. Used for lease operations 17,888 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety MCF TOTAL items 1-7 22,357 2. Lease Use 2.~'1(; MCF 8. NGL Qas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased Qas 3,305 ~~- n. . 0. ,.J. ~.J. if/ :Pi ~ ;y 10. Transferred from: WFU #1 761 11. Transferred to: 0 Commis@:>ner 0 Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60T Report due by the 20th of the month following the month in question. Signature 01 ~ Title Production ManaQer Authority 20 MC 25.235 Date: 04/11/2002 ~4A- Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log 02-Mar Facility Name West McArthur Production Facility Date & Time Event Gas Steps Taken to BeQin End MCF Planned Description of Incident Cateaorv Reason Actions Taken Minimize Recurrence Eauipment 1800 8:30AM Gas Compressor turned off Replace with new 3/12/02 3/16/02 2001 no Failed Bearings finfan compressor n/a 10:30am 16:30pm re-align motor with 3/18/02 3/18/02 138 yes compressor vibration alignment shut in skid compressor nla troubleshoot rebuilt fuel 6:30am 1:30PM low frequency on compressor and controller on 3/19/02 3-19-02 161 no turbines motor turbine n/a rebuilt fuel blow down volume 6:30am 8:30am Drip gas flooded fuel Over flow from controllers on tank and control 3/29/02 3/29/02 46 no controllers on turbines gas volume tank turbines gas regulators nla Total Flare 2346 Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthlYear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit April-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reiniected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- See 20 MC 25.235) 253 ., 5. Pilot and Purge 1,945 , 6. Used for lease operations 18,825 .. Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety I~ MCF TOTAL items 1-7 21,023 / 2. Lease Use 9vMCF 8. NGL gas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased aas 411 I(o,~... ,Á), ,tJ . t'kL (QLolo'J.- 10. Transferred from: WFU #1 1,390 11. Transferred to: 0 comm~sioner 0 Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60T Report due by the 20th of the month following the month in question. -:4r /? ~ Title Production ManaQer Authority 20 AAC 25.235 SignatuÇ ~ Date: 05/06/2002 Form 10-422 Rev 04/00 IN o o "- IN o o ~ Forest Oil Corporation Excess Flare Log APRIL, 2002 Facility Name West McArthur Production Facility ~ tf. j ..: ...< ...... o Eo-< tf. ~ o ¡.. Date & Time Event Gas Steps Taken to Date Time MCF Planned Description of Incident Catecorv Reason Actions Taken Minimize Recurrence Eauipment UNPLANNED EVENT: COMPRESSOR WENT DOWN ON HIGH DISCHARGE TEMP AT CLEANED 04102/02 080011100 69 NO 300DEG. STUCK SELENOID SELENOID NIA PLANNED EVENT, ROUTINE MAINTENANCE: REDUCING PRESSURE ON PIPELINE TO 500 PSI. BY BURNING OFF THROUGH CLEARING PIPELINE 04122/02 090011200 69 YES TURBINES. RIGHT OF WAY UNPLANNED EVENT: COMPRESSOR LET COOL DOWN ON HIGH DISCHARGE TEMP. AT 300 SELENOID DOWN AND 04/25102 1100/1200 23 NO DEG. PROBLEM RESTART NIA PLANNED EVENT: TESTING FLOWRATE ON TO TEST FLOW RAN PIPELINE FROM WFU #1 TO WEST MAC RATE INTO COMPRESSOR 04128102 110011500 92 YES FAC. PIPELINE TO BURN GAS Total 253 """ o cc 00 00 ~ IN t- o C) ~ IN an .. C) o IN o o IN "- "'" o "- cc o Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthNear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit May-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- / See 20 MC 25.235) 713 .v 5. Pilot and Purge 3,647 6. Used for lease operations 16,130 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety '113 MCF TOTAL items 1-7 20,490 2. Lease Use MCF 8. NGL ç¡as eQuivalent produced 0 3. Conserv. Purposes MCF 9. Purchased ç¡as 1,169 ( (JIIA. .~ ~ I( I ö ~ 10. Transferred from: WFU #1 132 11. Transferred to: 0 Commis~nerU Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of60'F. Report due by <:¿t ¿~ the 20th of the month following the month in question. Signature Title Production ManaQer Date: 06/17/2002 Authority 20 AAC 25.235 lJféL Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log May-02 Facility Name West McArthur Production Facility Date & Time Event Gas Steps Taken to Date Time MCF Planned Description of Incident Category Reason Actions Taken Minimize Recurrence Equipment 21301 EXCESS OIL CLEANED gas 05/11/2002 2230 23 YES SHUT DOWN COMPo MAINT. USE FIL TER NIA compressor 141 01 PIPELINE FLOW TEST gas 05/12/2002 1810 92 YES SHUT DOWN COMPo BLEED DOWN WFU#1 NIA NIA compressor 16201 PIPELINE FLOW TEST gas 05/13/2002 1720 23 YES SHUT DOWN COMPo BLEED DOWN WFU#1 NIA N/A compressor CHANGE 08001 SEPERA TOR & gas 05/18/2002 1000 46 YES SHUT DOWN COMPo MAl NT. OIL FIL TERS N/A N/A compressor 21 001 EXCESS OIL gas 05/23/2002 0000 69 YES SHUT DOWN COMPo MAINT. USE N/A NIA compressor rebuilt scavenger oil 13301 EXCESS OIL check valve at gas 05/26/2002 1730 92 YES SHUT DOWN COMPo MAl NT. USE YES compo Oil inlet compressor NOT ENOUGH 08001 PULLING #7 GAS WITH ONLY gas OS/29/2002 1200 92 YES SHUT DOWN COMPo JET PUMP 2 WELLS N/A N/A compressor 06001 MAl NT. AND gas 05/31/2002 1800 276 YES SHUT DOWN COMPo REPAIRS REPAIRS NIA NIA compressor Total 713 Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthNear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit June-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- See 20 MC 25.235) 115 ./ 5. Pilot and Purge 3,181 6. Used for lease operations 18,715 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety J/5MCF TOTAL items 1-7 22,011 2. Lease Use MCF 8. NGL gas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas 392 f £I A.. ..... ~. .0 i J '¡ð~ 10. Transferred from: WFU #1 993 11. Transferred to: 0 Commissi~ner 0 Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60'F. Report due by the 20th of the month following the month in question. signatur~'i ~ Title Production ManaQer Date: 07/09/2002 Authority 20 AAC 25.235 :TfY!- Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log June-02 Facility Name West McArthur Production Facility Date & Time Event Gas Steps Taken to Begin End MCF Planned Description of Incident Category Reason Actions Taken Minimize Recurrence Equipment SHUT DOWN GAS CHANGING OUT 06-02-02 1700 1 COMPRESSOR, POWER OIL 5:00PM 1900 46 YES WELLS SHUT IN REPAIRS CHOKE NIA NIA N/A 6/7/2002 0730 1 CLEANED OIL 7:30AM 0830 23 YES COOLER MAINTENANCE CLEANING NIA N/A N/A 6/22/02 0800 1 SHUT DOWN GAS EXCESS OIL CLEARED 8:00AM 0900 23 YES COMPRESSOR. MAINTENANCE USAGE. FILTER NIA NIA SCAVENGER 6/23/02 0800 1 SHUT DOWN GAS LINE 800AM 0900 23 YES COMPRESSOR MAINTENANCE MODIFICATION N/A NIA NIA Total 115 Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthNear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit July-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- See 20 MC 25.235) ~ 5. Pilot and Purge 2,046 6. Used for lease operations 19,494 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety MCF TOTAL items 1-7 21,540 2. Lease Use MCF 8. NGL gas eQuivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas - 10. Transferred from: WFU #1 1,821 11. Transferred to: 0 Commissioner Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of ',.Ji r [~~~::anaaer 14.65 psia and to a temperature of 60' F. Report due by Signature 1212 11. the 20th of the month following the month in question. Date: 08/14/2002 Authority 20 AAC 25.235 . r (}f) Form 10-422 Rev 04/00 ~ ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthNear of Disposition West McArthur River Unit FOREST 01 L CORPORATION West McArthur River Unit August-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- / See 20 AAC 25.235) 138 ''J' 5. Pilot and PurQe 1,549 6. Used for lease operations 19,579 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety '~MCF TOTAL items 1-7 21,266 2. Lease Use MCF 8. NGL gas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas - C W}\\J\M..IÝ ((1 J f, ~&I 10. Transferred from: WFU #1 1,730 ¡ t(J -/6 .h.6Y 11. Transferred to: 0 Commis~oner () Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60T Report due by the 20th of the month following the month in question. š4-'1~ Authority 20 AAC 25.235 Signature . . Title Production ManaQer Date: 09/13/2002 Ted Kramer Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log 02-Aug Facility Name West McArthur Production Facility Date & Time Event Gas Steps Taken to Beain End MCF Planned Description of Incident Category Reason Actions Taken Minimize Recurrence Equipment REPLACE ADJUST LIQUID 8-23-02 0700 / HIGH LIQUID LEVEL CHECK VALVE LEVEL ON 7:00AM 1000 69 NO IN SCRUBBER REPAIRS IN DUMP LINE NIA SCRUBBER NIA 8/28/02 1000 1 PLUMB IN GREASE WASH OIL 10:00PM 13:00 69 YES LINES TO BEARINGS MAINTENANCE COOLER NIA NIA NIA Total 138 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthlYear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit September-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- / See 20 MC 25.235) 23 '" 5. Pilot and PurQe 2,911 6. Used for lease operations 17,464 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety 23MCF TOTAL items 1-7 20,398 2. Lease Use MCF 8. NGL Qas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased Qas 242 (~MA_ lLU' ~b fat /. 10. Transferred from: WFU #1 1,242 /CYc.iJr 11. Transferred to: 0 Commis~oner 0 Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psi a and to a temperature of 60'F. Report due by the 20th of the month following the month in question. Signature a ~ ~ Authority 20 AAC 25.235 Title Production Manaqer Date: 10/15/2002 Ted Kramer ~ Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log Sep-02 Facility Name West McArthur Production Facility Date & Time (military) Event Gas Steps Taken to Begin End MCF Planned Descriction of Incident Cateaorv Reason Actions Taken Minimize Recurrence Equipment 09-25-2002 09/25/2002 GAS COMPRESOR CHANGE BEL T 10:00 11:00 23 YES SHUT DOWN MAl NT. ON FAN MOTOR NIA NIA N/A Total 23 Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthNear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit O€tober-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- 0 See 20 AAC 25.235) ~ 5. Pilot and Purge 1,634 6. Used for lease operations 24,338 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety MCF TOTAL items 1-7 25,972 2. Lease Use MCF 8. NGL Qas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas 2,633 10. Transferred from: WFU #1 67 11. Transferred to: 0 Commissioner Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60'F. Report due by the 20th of the month following the month in question. s¡gnatureØAf ~~ Authority 20 AAC 25.235 Title Production ManaQer Date: 11/12/2002 Ted Kramer Form 10-422 Rev 04/00 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthNear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit 11/1/2002 Revision 1 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold Pool Name Code Percent 0 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd-See 20 AAC 25.235) 69 5. Pilot and Purge 1,589 6. Used for lease operations 19,191 Official Use Only-Flaring Authorization> 1 hr. 7. Other 0 1 . Safety MCF TOTAL items 1-7 20,849 2. Lease Use MCF 8. NGL Qas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas 2,689 10. Transferred from: WFU #1 11. Transferred to: Commissioner Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60'F. Report due by Signaturd..-þ"~",~ nle Senior Vice President the 20th of the month following the month in question. Authority 20 AAC 25.235 Date: 9/15/2006 Leonard Gurule Form 10-422 Rev 04/00 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION "\ 1. Sold MonthNear of Disposition Novem ber-02 Indicate contributions of each pool to total. Facility West McArthur River Unit Disposition Operator Field(s) "fOREST OIL CORPORATION West McArthur River Unit Volume MCF o Pool Name Code Percent 2. Rein'ected West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 4. Flared or vented greater than 1 hour. (Supplemental report req'd- See 20 MC 25.235 8. NGL 6.9 1,589······ 28,070 o 29,728 o ¡./ Official Use Only-Flaring Authorization >1 hr. 7. Other 1. Safet 2. Lease Use 3. Conserv. Pur oses o cr MCF MCF MCF ..f.l- 9. Purchased as 2,689· 10. Transferred from: WFU #1 11. Transferred to: Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60T Report due by the 20th of the month following the month in question. Authority 20 AAC 25.235 Production ManaQer Date: 12/12/2002 Ted Kram Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log Facility Name 02-Nov West McArthur Production Facility Date & Time Event Gas Steps Taken to Beain End MCF Planned Description of Incident Cate!1orv Reason Actions Taken Minimize Recurrence Equioment replaced change out ball valves valves & gas 11/03/2002 12:00 11/03/200215:00 69 YES & oil filters maintenance leaky valves filters nla compressor Total 69 Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) MonthlYear of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit December-02 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold 0 Pool Name Code Percent 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd- .1/ See 20 MC 25.235) 138 5. Pilot and Purge 1,661 6. Used for lease operations 22,164 Official Use Only-Flaring Authorization >1 hr. 7. Other 0 1. Safety \3ßMCF TOTAL items 1-7 23,963 2. Lease Use MCF 8. NGL gas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas 3,388 IrLfu /CLu/,~' Uý d/,o/{)~ 10. Transferred from: 11. Transferred to: Commi~ioner 0 Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60' F. Report due by the 20th of the month following the month in question. Signature -ì/7 -t£ ~ Authority 20 AAC 25.235 Title Production Manaqer Date: 01/17/2003 ed Kramer -:Jl2>t2- Form 10-422 Rev 04/00 Forest Oil Corporation Excess Flare Log Facility Name 02-Dec West McArthur Production Facility - West McArthur Field Date & Time Event Gas Steps Taken to Beqin End MCF Planned Description of Incident Category Reason Actions Taken Minimize Recurrence Equipment 12/19/2002 SHUT DOWN 12/19/2002 11 :00:00 GROUND FAULT IN START #3 ON 5:00:00 PM PM 138 NO TURBINE TURBINE PURPOSE NIA NIA Total 138 Flare_Log.xls Page 1 ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION Facility Operator Field(s) Month/Year of Disposition West McArthur River Unit FOREST OIL CORPORATION West McArthur River Unit 11/1/2002 Revision 1 Disposition Volume MCF Indicate contributions of each pool to total. 1. Sold Pool Name Code Percent 0 2. Reinjected 0 West McArthur River 930148 100% 3. Flared or vented less than 1 hour. 0 4. Flared or vented greater than 1 hour. (Supplemental report req'd-See 20 AAC 25.235) 69 5. Pilot and Purge 1,589 6. Used for lease operations 19,191 Official Use Only-Flaring Authorization> 1 hr. 7. Other 0 1. Safety MCF TOTAL items 1-7 20,849 2. Lease Use MCF 8. NGL gas equivalent produced 0 3. Conserv. Purposes MCF 9. Purchased gas 2,689 10. Transferred from: WFU #1 11. Transferred to: Commissioner Date Remarks: Associated gas is approximately 15% nitrogen. Gas is used for lease operations including heaters and turbine generators. I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected to pressure of 14.65 psia and to a temperature of 60T Report due by SignaturL-/..4~ Title Senior Vice President the 20th of the month following the month in question. Authority 20 AAC 25.235 Date: 9/15/2006 Leonard Gurule Form 10-422 Rev 04/00