Department of Commerce, Community, and Economic Development
Alaska Oil and Gas Conservation
Commission
HOME
EVENTS
DATA
Data List
Drilling
Production
Orders
Data Miner
Document Search
REPORTS
Reports and Charts
Pool Statistics
FORMS
LINKS
Links
Test Notification
Data Requests
Regulations
Industry Guidance Bulletins
How to Apply
ABOUT US
History
Staff
HELP
Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
West McArthur River Gas Disposition
State of Alaska AOGCC Gas Disposition Files Year: 2013 Facility: W McArthur River Operator: COOK INLET ENERGY, LLC STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. hNear of Disposition Jan -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold - Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) VT 10. Pilot and Purge 25 11. Assist Gas 12. Fuel gas used in lease operations. 5,130 13. Other (see instructions) Official Use Only Authorization >1 hr. Safety 3 1, v! MCF 14. TOTAL VOLUME (ITEMS 6.13) 5,194 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: Commissioner C Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature_ /7 /��` Note: All volumes must be corrected Title Chief Executive Officer to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name David Hall Phone 334-6745 Date o7 i3 �o , 3 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 1/1/2013 Date & Time Begin End Event Gas MCF Planned Description of Incident Category Reason Actions Taken Steps Taken to I Minimize Recurrence Equipment 1-3-13 04:00 1-3-13 05:30 39 No Plugged inlet screen maintenance plugged screen cleaned screen none K-200 Gas compressor Flare Total for Month 1 39 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. Month/Year of Disposition Feb -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold - Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 15 9. Flared or vented more than 1 hour (see instr.) 147 10. Pilot and Purge 22 11. Assist Gas 12. Fuel gas used in lease operations. 4,501 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety I MCF 14. TOTAL VOLUME (ITEMS 6-13) 4,685 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: ✓ 'A� - 4--1-/3 Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. f Note: All volumes must be corrected Signature /� �`�"� Title Chief Executive Officer to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Nam avid Hall Phone 334-6745 Date, �% fO C3 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit m Duplicate Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 2/1/2013 Date & Time Begin End Event Gas MCF Planned Description of Incident Category Reason Actions Taken Steps Taken to I Minimize Recurrence Equipment 2-8-13 17:30 2-8-13 18:30 15 No Power outage Unplanned Power outage Restarted after getting power back to the unit N/A K-200 Gas compressor 2/9/13 07:30 2/9/13 09:00 27 NO Power outage Unplanned Power outage Restarted after getting power back to the unit N/A K-200 Gas compressor 2/11/13 09:00 2/11/13 13:00 79 1 NO Power outage / Maintenance Unplanned Power outage / Maintenace ene watt es at and started unit after we got power back on. N/A K-200 Gas compressor 2/18/13 12:20 2/18/13 14:15 41 NO High Temp Shut Down Unplanned Plugged Screen Replaced Screen N/A K-200 Gas compressor Flare Total for Month 1 162 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. Month/Year of Disposition Mar -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 33 9. Flared or vented more than 1 hour (see instr.) 31 10. Pilot and Purge 25 11. Assist Gas 12. Fuel gas used in lease operations. 5,499 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6.13) 5,588 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: / to 13 Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature Title Chief Executive Officer t0 pressure Of 14.65 pSla and t0 a temperature of 60o F. Authority 20 Printed Name D id Hall Phone 334-6745 Date -1116111;-.3 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 3/1/2013 Date & Time Begin End Event Gas MCF Planned Description of Incident Category Reason Actions Taken Steps Taken to Minimize Recurrence Equipment 3/25/13 0:00 3/25/13 01:30 31 No High 2nd stage temps and high 2nd stage suction pressure. Service Service changed out 2nd stage witches hat. NA K-200 Gas compressor 3/26/13 18:00 3/26/13 19:00 33 No Replaced purge gas Dwyer tube. Service Service Replaced tube with a new one. K-200 Gas compressor Flare Total for Month 64 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition Apr -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold - Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 82 10. Pilot and Purge 24 11. Assist Gas 12. Fuel gas used in lease operations. 5,048 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety �7 MCF 14. TOTAL VOLUME (ITEMS 6-13) 5,154 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: ' '/, Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. `,J,0 Note: All volumes must be corrected Signature _ ✓` Title Chief Executive Officer to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Nameid Hall Phone 334-6745 Date .5 o Zvc 3 AAC25.235. C Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 4/1/2013 Date & Time Begin End Event Gas MCF Planned Description of Incident Category Reason Actions Taken Steps Taken to I Minimize Recurrence Equipment 4/19/13 16:00 4/19/13 20:00 82 No Power outage Unplanned Power outage Restarted after getting power back. N/A K-200 Gas compressor Flare Total for Month 1 82 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition May -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 2,681 10. Pilot and Purge 25 11. Assist Gas 12. Fuel gas used in lease operations. 2,028 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 4,734 Lease Use MCF 15. NGL Gas Equivalent Conservation 2 v I p MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 3,738 , / ! �7 � /S-, / Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knovledge. Note: All volumes must be corrected Signature Title Chief Executive Officer _ to pressure of 14.65 psis and to a Printed Name David Hall temperature of 60o F. Authority 20 Phone 334-6745 Date a 7 � 3 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 5/1/2013 Date & Time Event Gas Steps Taken to Begin End MCF Planned Description of Incident Cateciory Reason Actions Taken Minimize Recurtence Equipment Replaced 2nd 5-9-13 5-9-13 FK-200went down on stage discharge K-200 @13:00 @17:00 98 NOgh temp Maintenance Bad valves Replace valves valves 5-15-13 5/15/13 N/A @13:00 24:00 158 YES Flare excess Gas Planned Excess Gas N/A N/A 5/16113 5/16/13 N/A 00:01 24:00 1 337 YES Flare excess Gas Planned Excess Gas N/A N/A 5/17/13 5/17/13 N/A 00:00 24:00 330 1 YES Flare excess Gas Planned Excess Gas N/A N/A 5/18/13 5/18/13 N/A 00:00 24:00 330 YES Flare excess Gas Planned Excess Gas N/A N/A 5/19/13 5/19/13 N/A 00:00 24:00 298 YES Flare excess Gas Planned Excess Gas N/A N/A 5/20/13 5/20/13 Flare excess Gas / N/A 00:00 24:00 376 YES Power outage Planned I Excess Gas N/A N/A 5/20/13 5/20/13 N/A 00:00 24:00 264 YES Flare excess Gas Planned Excess Gas N/A N/A 5/21/13 5/21/13 N/A 00:00 24:00 264 YES Flare excess Gas Planned Excess Gas N/A N/A 5/22/13 5/22/13 NIA 00:00 24:01 444 YES Flare excess Gas Planned I Excess Gas N/A N/A 5/23/13 5/23/13 N/A 00:00 24:01 446 YES Flare excess Gas Planned Excess Gas N/A N/A Flare_Log.xls Page 1 Date & Time Event Gas Steps Taken to Begin End MCF Planned Description of Incident Catewiv Reason Actions Taken Minimize Recurrence E ui ment 5/24/13 5124/13 N/A 00:00 24:01 380 YES Flare excess Gas Planned Excess Gas N/A N/A 5/25/13 5125/13 N/A 00:00 24:01 207 YES Flare excess Gas Planned Excess Gas N/A N/A 5/26/13 5126113 NIA 00:00 24:01 212 YES Flare excess Gas Planned I Excess Gas N/A N/A 5/27/13 5127/13 N/A 00:00 24:01 283 YES Flare excess Gas Planned Excess Gas N/A N/A 5/28113 5/28/13 N/A 00:00 24:00 278 YES Flare excess Gas Planned Excess Gas N/A NIA 5129/13 5/29/13 N/A 00:00 24:00 164 YES Flare excess Gas Planned Excess Gas N/A N/A 5/30/13 5/30/13 N/A 00:00 24:00 100 YES Flare excess Gas Planned Excess Gas N/A N/A =00:00 5/31/13 24:00 104 YES Flare excess Gas Planned Excess Gas N/A N/A N/A Flare Total for Month 5,073 Flare_Log.xls Page 2 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. OperatorMonthNear Cook Inlet Energy, LLC 5. of Disposition Jun -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 2,323 10. Pilot and Purge 24 11. Assist Gas 12. Fuel gas used in lease operations. 1,985 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 4,332 Lease Use MCF 15. NGL Gas Equivalent Conservation 2 " j MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 5,251 Commissioner JDate 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. All volumes must be corrected Signature Title Chief Executive Officer to to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Nam avid Hall Phone 334-6745 Date `�vf 3 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate ALF 6M3 - Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 6/l/2013 Date & Time Begin End Event Gas MCF Planned Descri tion of Incident Cate o Reason Actions Taken Steps Taken to Minimize Recumance Equipment 611/13 6/1/13 00:00 24:00 121 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/2/13 6/2/13 00:00 24:00 142 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/3/13 6/3/13 00:00 24:00 160 YES Flare excess Gas Planned Excess Gas N/A N/A NIA 614/13 6/4/13 00:00 24:00 156 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/5/13 6/5/13 00:00 24:00 151 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/6/13 6/6/13 00:00 24:00 156 1 YES Flare excess Gas Planned I Excess Gas N/A N/A N/A 6/7/13 6/7/13 00:00 24:00 213 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 618/13 6/8/13 00:00 24:00 202 YES Flare excess Gas Planned Excess Gas N/A N/A NIA 6/9/13 6/9/13 00:00 24:00 204 1 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/10/13 6/10/13 00:00 24:00 195 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/11/13 6/11113 00:00 24:00 213 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/12/13 6/12113 00:00 24:00 221 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/13/13 6/13/13 00:00 24:00 196 YES Flare excess Gas Planned Excess Gas N/A N/A N/A Flare_Log.xls Page 1 Date & Time Begin End Event Gas MCF Planned Description of Incident Category Reason Actions Taken Steps Taken to Minimize Recurrence I Equipment 6/14/13 6/14/13 00:00 24:00 161 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/15/13 6/15/13 00:00 24:00 162 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/16/13 6/16/13 00:00 24:00 146 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/17/13 6/17/13 00:00 24:00 171 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/18/13 6/18/13 00:00 24:00 188 YES Flare excess Gas Planned Excess Gas N/A N/A NIA 6/19/13 6/19/13 00:00 24:00 198 YES Flare excess Gas Planned Excess Gas NIA N/A N/A 6/20/13 6/20/13 00:00 24:00 190 YES Flare excess Gas Planned I Excess Gas N/A NIA NIA 6/21/13 6/21/13 00:00 24:00 180 YES Flare excess Gas Planned Excess Gas NIA N/A N/A 6/22/13 6/22/13 00:01 24:01 155 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/23/13 6/23/13 00:02 24:02 153 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/24/13 6/24/13 00:03 24:03 152 YES Flare excess Gas Planned Excess Gas NIA N/A N/A 6/25/13 6/25/13 00:00 24:04 158 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/26/13 6/26/13 00:00 24:00 168 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 6/27/13 6/27/13 00:00 24:00 163 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/28/13 6/28/13 00:00 24:00 164 YES Flare excess Gas Planned Excess Gas NIA N/A N/A Flare_Log.xls Page 2 Date &Time Be in End Event Gas MCF Planned Description of Incident Cat o Reason Actions Taken Steps Taken to Minimize Recurrence Equipment 6/29/13 6/29/13 00:00 24:00 164 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 6/30/13 6/30/13 00:00 24:00 152 YES Flare excess Gas Planned Excess Gas N/A NIA N/A Flare Total for Month5,155 Flare_Log.xls Page 3 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition Jul -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold _ Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 2,852 10. Pilot and Purge 25 11. Assist Gas 12. Fuel gas used in lease operations. 1,672 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety , MCF 14. TOTAL VOLUME (ITEMS 6-13) 4,549 Lease Use MCF 15. NGL Gas Equivalent Conservation 2 MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 5,368 ///��� /S _/ /J /Commissioner YY---�CC�� Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature Title Chief Executive Officer to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed N avid Hall Phone 334-6745 Date �/l 3 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 7/1/2013 Date & Time Begin End Event GasSteps MCF Planned Description of Incident Category Reason Actions Taken Taken to Minimize Recurrence Equipment 7/1/13 7/1/13 00:00 24:00 119 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/2/13 7/2113 00:00 24:00 134 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/3/13 7/3/13 00:00 24:00 138 1 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/4/13 7/4/13 00:00 24:00 115 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/5/13 7/5/13 00:00 24:00 156 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/6/13 7/6/13 00:00 24:00 151 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/7/13 7/7/13 00:00 1 24:00 156 1 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/8/13 7/8/13 00:00 24:00 126 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/9113 7/9/13 00:00 24:00 98 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/10/13 7/10/13 00:00 24:00 100 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/11/13 7/11/13 00:00 1 24:00 96 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/12113 7/12/13 00:00 24:00 147 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 7/13/13 7/13/13 00:00 24:00 281 YES Flare excess Gas Planned Excess Gas N/A N/A N/A Flare_Log.xls Page 1 Date & Time Event Gas Steps Taken to B in End MCF Planned Description of Incident Category Reason Actions Taken Minimize Recurrence Equipment 7/14/13 7/14/13 00:00 24:00 301 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/15/13 7115/13 00:00 24:00 319 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/16/13 7/16/13 00:00 1 24:00 322 1 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/17/13 7117/13 00:00 24:00 292 YES Flare excess Gas Planned Excess Gas NIA N/A N/A 7/18113 7/18/13 00:00 24:00 305 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/19113 7/19/13 00:00 24:00 311 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/20/13 7/20/13 00:00 24:00 315 YES Flare excess Gas Planned Excess Gas NIA N/A N/A 7/21/13 7/21/13 00:00 24:00 320 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 7/22/13 7/22/13 00:01 24:01 316 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/23113 7/23/13 00:02 24:02 278 YES Flare excess Gas Planned Excess Gas N/A NIA NIA 7/24113 7/24/13 00:03 24:03 108 YES Flare excess Gas Planned Excess Gas N/A N/A NIA 7/25/13 7/25/13 00:00 24:04 111 YES Flare excess Gas Planned Excess Gas NIA N/A N/A 7/26/13 7126/13 00:00 24:00 111 YES Flare excess Gas Planned Excess Gas N/A N/A NIA 7/27/13 7/27/13 00:00 24:00 115 YES Flare excess Gas Planned Excess Gas N/A NIA NIA 7/28/13 7/28/13 00:00 24:00 109 YES Flare excess Gas Planned Excess Gas N/A N/A N/A Flare_Log.xls Page 2 Date & Time Event Gas Steps Taken to Begin End MCF Planned Description of Incident Cat o Reason Actions Taken Minimize Recurence Equipment 7/29/13 7/29/13 00:00 24:00 108 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7/30/13 7/30/13 00:00 24:00 111 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 7131/13 7/31/13 00:00 24:00 103 YES I Flare excess Gas Planned I Excess Gas I N/A N/A N/A Flare Total for Month 5,772 Flare_Log.xls Page 3 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCFn (;oS nicpnc1T1nK1 -- 1. Facility Number 2. Facility Name 1330000027 West McArthur River Disposition ---- — — 3. Field West McArthur River Volume MCF --------.�.. vv...v.. 4. Operator 5. MonthtVear of Disposition Unit Cook Inlet Energy, LLC Aug 13 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 363 10. Pilot and Purge 25 11. Assist Gas 12. Fuel gas used in lease operations. 4,539 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety �� MCF 14. TOTAL VOLUME (ITEMS 6.13) 4 927 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 4,927 J/ Comnrflssioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature // �C�/ Note: All volumes must be corrected Title Chief Executive officer to pressure of 14.65 psia and to a 9 _5 temperature of 60o F. Authority 20 Printed Name Dated Hall Phone 334-6745 Date AAC25.235. Form 10422 Rev. 512009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate I,IL f - 4'13J1¢ Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 8/1/2013 Date & Time Event Gas Steps Taken to Begin End MCF Planned Descri tion of Incident Category Reason Actions Taken Minimize Rew ence Equipment 8/1/13 8/1/13 00:00 24:00 102 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 8/2/13 8/2/13 00:00 24:00 72 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 8/3/13 8/3/13 00:00 24:00 89 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 8/4/13 8/4/13 00:00 24:00 91 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 8/5/13 8/5/13 00:00 24:00 86 YES Flare excess Gas Planned Excess Gas N/A N/A NIA 8/6/13 8/6/13 00:00 24:00 79 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 8/7/13 8/7/13 00:00 24:00 30 YES Flare excess Gas Planned Excess Gas N/A N/A N/A 8/8/13 8/8/13 00:00 24:00 27 YES Flare excess Gas Planned Excess Gas N/A NIA NIA 8/10/13 8/10/13 00:00 24:00 34 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 8/15/13 8/15/13 00:00 24:00 17 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 8/18/13 8/18/13 00:00 24:00 26 YES Flare excess Gas Planned Excess Gas I N/A N/A N/A Flare_Log.xls Page 1 Date & Time Begin End Event Gas MCF Planned Description of Incident Category Reason Actions Taken Steps Taken to Minimize Recurrence Equipment 8/19/13 8/19/13 00:00 24:00 13 YES Flare excess Gas Planned Excess Gas N/A NIA N/A 8/20/13 8/20/13 00:00 24:00 61 YES Flare excess Gas Planned Excess Gas NIA NIA N/A Flare Total for Month 727 Flare_Log.xls Page 2 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. Month/Year of Disposition Sep -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold _ Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 93 10. Pilot and Purge 24 11. Assist Gas 12. Fuel gas used in lease operations. 5,256 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety MCF 14. TOTAL VOLUME (ITEMS 6-13) 5,373 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 5,383 _ / —/S _/_ Commissioner SC.•�— Date �F/ 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Signature. Note: All volumes must be corrected Title Chief Executive Officer to pressure of 14.65 psia and to a / temperature of 60o F. Authority 20 Printed Name David Hall Phone 334-6745 Date %©(l �J AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate VLA Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 9/1/2013 Date & Time Begin End Event Gas MCF Planned Descrilotion of Incident Cateoory Reason Actions Taken Steps Taken to Minimize Recurrence Equipment 914/13 00:00 9/4/13 24:00 9 NO Replaced purge gas regulator Maintenance Service Replaced regulator with a new one. N/A K-200 Gas compressor 9/24/13 17:00 9/24/13 20:00 32 YES Service compressor Maintenance Maintenance Serviced N/A K-200 Gas compressor 9/27/13 12:30 9/27/13 16:00 52 NO Flared gas Facility shutdown Power Outage N/A N/A N/A Flare Total for Month 93 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition Oct -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold _ Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 99 10. Pilot and Purge Y5 11. Assist Gas 12. Fuel gas used in lease operations. 7,114 13. Other (see instructions) Official Use Only Authorization>1 hr. Safety � MCF 14. TOTAL VOLUME (ITEMS 6-13) 7,238 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 5,534 7-�/S^_ / Commissioner / Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature P Title Chief Executive Officer to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name,0160 Hall Phone 334-6745 Date / t! �0 `-3 AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 10/1/2013 Date & Time Begin End Event Gas MCF Planned Description of Incident Cateqory Reason Actions Taken Steps Taken to Minimize Recumence E ui ment 10/9/13 00:00 10/9/13 24:00 52 YES K200 maintenance Maintenance Change oil/filters N/A N/A K-200 Gas compressor 10/27/13 11:30 10/27/13 15:30 47 YES K-200 shutdown on high temp Maintenance Plugged K-200 suction screen Cleaned screen N/A K-200 Gas compressor Flare Total for Month 99 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODIJCM [.oS n1Spnc1T1nti 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition Nov -13 Disposition Volume MCF TO- production from multiple pools, list contribution of each pool as a percent or Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 196 10. Pilot and Purge 24 11. Assist Gas 12. Fuel gas used in lease operations. 6,834 13. Other (see instructions)U Authorization >1 hr. Safety / GZ /_ Y MCF~ i 14. TOTAL VOLUME (ITEMS 6-13) 7,054 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 5,245 Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. ✓vLf Note: All volumes must be corrected Signature_ Title Chief Executive Officer to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed a David Hall Phone 334-6745 Date /� AA C25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate V1—F b/3J� Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 11/1/2013 Date 8 Time Begin End Event Gas MCF Planned Descrl tion of Incident Gate o Reason Actions Taken Steps Taken to Minimize Recurrence E ui ment 11/16/13 20:00 11/16/13 21:00 33 NO K-200 shutdown maintenance test ESD replace P-101 pump N/A K-200 Gas compressor 11/17/13 13:00 11/17/13 15:30 163 NO K-200 shutdown maintenance replace P-101 pump replace P-101 pump N/A K-200 Gas compressor Flare Total for Month 1 196 Flare_Log.xls Page 1 STATE OF ALASKA ALASKA OIL AND GAS CONSERVATION COMMISSION FACILITY REPORT OF PRODUCED GAS DISPOSITION 1. Facility Number 1330000027 2. Facility Name West McArthur River 3. Field West McArthur River Unit 4. Operator Cook Inlet Energy, LLC 5. MonthNear of Disposition Dec -13 Disposition Volume MCF 20. For production from multiple pools, list contribution of each pool as a percent of Total Volume. 6. Sold Pool Name Pool Code Percent 7. Reinjected West McArthur River 930148 100% 8. Flared or vented 1 hour or less 9. Flared or vented more than 1 hour (see instr.) 402 10. Pilot and Purge 25 11. Assist Gas 12. Fuel gas used in lease operations. 9,998 13. Other (see instructions) Official Use Only Authorization >1 hr: Safety Lr MCF 14. TOTAL VOLUME (ITEMS 6-13) 10,425 Lease Use MCF 15. NGL Gas Equivalent Conservation MCF 16. Purchased gas Waste: MCF 17. Transferred from: West Foreland 5,239 Commissioner Date 18. Transferred to: (Express as a negative #) 19. Remarks: I hereby certify that the foregoing is true and correct to the best of my knowledge. Note: All volumes must be corrected Signature >c� �hv.iQ NaX Title Chief Executive Officer to pressure of 14.65 psia and to a temperature of 60o F. Authority 20 Printed Name David Hall Phone 334-6745 Date AAC25.235. Form 10-422 Rev. 5/2009 INSTRUCTIONS ON REVERSE SIDE Submit in Duplicate rt. 41311y - Facility Name West McArthur Production Facility COOK INLET ENERGY Excess Flare Log Use Military form for time logs 12/1/2013 Date &Time B in End Event Gas MCF Planned Descri tion of Incident Cat o Reason Actions Taken Steps Taken to Minimize Recurrence Equipment 12/4/13 08:30 12/4/13 10:30 33 Yes K-200 shutdown maintenance K-200 down to change start up screen Cleaned screen N/A K-200 12/10/13 17:20 12/10/13 19:00 17 NO Power outage unplanned shutdown KPF trubine troubles N/A N/A K-200 12/12/13 14.30 12/12/13 1800 220 NO K-200 shutdown maintenance K200 down to clean screen Cleaned screen N/A K-201 12/17/13 20:00 12/18/13 02:30 101 NO K-200 shutdown maintenance K-200 maintinence/ Desi line re -build install new Flow lines N/A K-202 12/19/13 07:30 12/19/13 10:00 31 NO K-200 shutdown maintenance 1 st stage scrubber froze up thawed scrubber increased cooler temps K-203 Flare Total for Month 402 Flare_Log.xls Page 1